BRES2015-0110 Chimney InstructionsDuraTech 5" - 24"
Chimney Shroud
.O—WO-NO
DuraVent.
Member of 46 M&G Group
A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE
TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO
COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE
THAT THIS CHIMNEY BE INSTALLED ONLY IN
ACCORDANCE WITH THESE INSTRUCTIONS.
NOTE:
Read through all these instructions
before beginning your installation. Failure
toinstall the chimney as described in these
instructions will void the manufacturer's
warranty and may have an effect on your
homeowner insurance and UL listing
status. Refer to the DuraTech Chimney
Installation Instructions for complete details
on installing the DuraTech Chimney system.
Keep these instructions for future use.
Dear Customer, Installer, or End User:
We welcome any comments regarding matters
pertaining to our DuraVent products.
We welcome any ideas, input or complaints
and I'll make sure that someone responds
directly back to you.
Send your emails to:
president@duravent.com
If you are searching for tech support or product
information, please phone us at 800-835-4429.
Or email us at:
techsupport@duravent.com
APPLICATION AND LISTING
As specified in these instructions, Shrouds are
approved for use with DuraTech Chimney
(5"-24" diameter). A Shroud built and installed
in compliance with these instructions is UL
listed for use with DuraTech chimney (listing
number MH7399).
INSTALLATION NOTES
Practice good workmanship. Exercise
extreme caution when working on roofs. Be
sure to wear appropriate safety gear and
clothing as needed. Refer to the DuraTech
Chimney Installation Instructions for further
safety details.
MH7399
SHROUD REQUIREMENTS
Shrouds can either be field -fabricated or
factory -fabricated, but they must meet the
requirements as specified in these instructions.
Shrouds must be constructed of a minimum
24 gauge (.024") stainless steel, aluminized
steel, galvanized steel, or copper. Other
materials may also be used, such as brick,
mortar, stucco, stone, etc., provided they
are completely non-combustible. Check with
your local building code authorities for any
additional shroud requirements. Shrouds
must be able to be removed to allow chimney
access to properly clean the chimney.
DuraTech installations which include the use
of a shroud must comply with the following
requirements (Figure 1):
- DuraTech chimney must maintain at least 2"
clearance from combustible materials.
• The chase enclosure must be ventilated.
• The Chase Top Flashing or field -fabricated
chase pan must be used. Fieldfabricated
chase pans are acceptable if they meet these
requirements:
- Material must be 24 gauge (.024")
Galvanized steel or equivalent.
• Chase pan must have opening 3"
larger than outside diameter of
chimney pipe with at least a 1/2"
upturned flange/collar.
• Chase pan must overhang chase
by 112" per side for proper air flow.
• Chase pan must have a 1" down
urned outside edge (weather
protection).
ALLOW A 1 -INCH AIR GAP BETWEEN STORM
COLLAR AND CHASE TOP FLASHING
1/2" AIR SPACE ESTABLISHED
BYSPACERS
IT
1/2 -INCH
OVERHAN
5"-16" DIAMETER \
CHIMNEY MUST
EXTEND AT LEAST 3 -
INCHES, 18"-24" MUST
EXTEND AT LEAST 6 -
INCHES ABOVE CHASE
TOP FLASHING
DURATECH
CHIMNEY
CHIMNEY CAP
STORM COLLAR
CHASE TOP
FLASHING OR
CHASE PAN
ri
MAINTAIN 2 -INCH
CLEARANCE BETWEEN
DURATECH CHIMNEY AND
CHASEENCLOSURE
Figure 1
1 /2 -INCH `t I \
e �
1
r<
FIELD -FABRICATED
SPACERSFORCHASE
`. TOP FLASHING
3
- Field -fabricated spacers (1/2" tall, 24 gauge
or .024" Galvanized steel) must be
used to support the Chase Top Flashing or
chase pan, in order to provide air flow.
- 5"-16" DuraTech chimney must extend at
least 3" above the chase pan/flashing.
18"-24" DuraTech chimney must extend at
least 6" above chase pan/flashing.
- A DuraTech chimney cap must be used
inside the shroud.
- The Shroud must not be in direct contact with
any of the DuraTech components
(other than Chase Top Flashing).
- All Open Areas of the shroud must be
covered with 1/2" stainless or galvanized
steel mesh screen to prevent debris from
entering the Shroud.
- Shrouds must follow the dimensional
requirements specified in Tables 1, 2 or
3, depending on the style of shroud used.
The three basic shroud styles are a) House, b)
Arch or Mailbox, and c) Pyramid.
Most factory -fabricated shrouds will fall under
one of these basic style categories.
4
WARRANTY
DuraVent makes no warranty or representation
of any kind, either express
or implied, concerning the materials, quality,
workmanship or installation of the third -party
manufactured shrouds that may be used
in connection with the DuraTech Chimney
System. DuraVent expressly disclaims any and
all liability of any kind related to the materials,
quality, workmanship or installation of such
third party manufactured shrouds.
DuraVent warrants the accuracy of its
specifications for the selection of third -party
manufactured shrouds. Should a third -party
manufactured shroud require replacement
due to the inaccuracy of a DuraVent selection
specification, DuraVent's sole obligation and
liability will be to replace such shroud with
one of similar size and quality appropriate
to the installation. DuraVent's warranties are
otherwise limited to the warranties set forth in
the DuraTech Lifetime Limited Warranty.
HOUSE STYLE SHROUD
The House style shroud is roughly square or
rectangular with a closed top and
exhaust openings on four (4) sides. (Figure 2)
Table 1 lists the minimum Shroud
dimensions, the minimum Open Area per side,
and the minimum Total Open Area
for the Shroud, depending on the diameter of
DuraTech chimney used.
Shaded area represents screened Open Area. Actual shape
of Shroud may vary as long as minimum dimensions and
minimum Open Area requirements are met.
Y
Figure 2
H: Minimum height of Shroud
L: Minimum length of Shroud
W: Minimum width of Shroud
5
20
17
13
13
20
79
6
28
17
13
13
28
113
7
38
17
17
17
38
154
8
50
17
17
17
50
201
10
79
22
24
24
79
314
12
113
23
24
24
113
452
14
154
24.5
28 _.
28
u; 154
615
16
201
25
28
28
201
804
18
254
28
32
32
423
1692
20
314
28
32
32
524
2096
22
380
28
36
36
634
2536
24
452
28
36
36
750
3000
Table 1: House Style Shroud Minimum Dimensions
5
ARCH 1 MAILBOX STYLE SHROUD
The Arch or Mailbox style shroud generally has
two solid sides and a solid top. The exhaust
openings are on the two (2) open ends of the
arch. (Figure 3) Table 2 lists the minimum
Shroud dimensions, the minimum Open Area
per side, and the minimum Total Open Area
for the Shroud, depending on the diameter of
DuraTech chi
Shadedarea represents screened Open Area. Actual shape
of Shroud may vary as long as. minimum dimensions and
minimum Open Area requirements are met.
Figure 3
H: Minimum height of Shroud
L: Minimum length of Shroud
W: MiniMLM width of Shroud
Chimney
Diameter
(inches)
5
Chimney I Min Min Min Min Min
Open Area
Area Height Length Width Total ., en
per
(inches) H (inches) L (inches) W (inches) Area (sq. in)
20 17 13 13 39 79
6
28
17
13
13
57
113
7
38
17
17
17
77
154
8
50
17
17
17
100
201
10
79
22
24
24
-157
314
12
113
23
24
24
226
452
.14
154
24.5
28
28
308.
615
16
201
25
28
28
402
804
18
254
28
32
32
508
1016
20
314
28
32
32
628
1256
22
380
28
36
36
x760
1520
24
452
28
36
36
904
1808
Table 2: Arch/Mailbox Style Shroud Minimum Dimensions
R
PYRAMID STYLE SHROUD
The Pyramid style shroud is roughly square
or rectangular with an open top for exhaust as
well as openings along the base of the four
(4) sides. (Figure 4) Table 3 lists the minimum
Shroud dimensions, including the minimum
height and length of the base openings on the
sides, depending on the diameter of DuraTech
chimney.
Shaded area represents screened Open Area. Actual shape
of Shroud may vary as long as minimum dimensions and
minimum Open Area requirements are met.
rigure 4
L: Minimum length of Shroud top opening
W: Minimum width of Shroud top opening
1-11: Minimum total height of Shroud
B: Minimum length of opening along base
1-12: Minimum height of opening along base
Min Min Min
Length Width Base
5 17 13 13 7
1.0
6
17
13
13
7
1.0
7
17
17
17
11
1.0
8
17
17
17
11
1.0
10
22
24
24
18
1.5
12
23
24
24
18
2.0
14
24.5
28
28
22
2.0
16
25
28
28
22
2.5
18
30
35
35
24
3.0
20
30
35
35
24
3.0
22
30
39
39
24
4.0
24
30
39
39
24
4.0
Table 3: Pyramid Style Shroud Minimum Dimensions
7
M&G DURAVENT WARRANTY
M&G DuraVent, Inc ("DuraVent') provides this limited lifetime warranty for all of its products to the original purchaser, with,the exception ofVentinox (lifetime),
DuraBlack (five years) and all Termination Caps (five years). Subject to the limitations set forth below, DuraVent warrants th at its products will be free from
substantial defects in material or manufacturing, if properly installed, maintained and used. This Warranty is non-transferab.e with the exception ofVentinox
which is transferable from the original homeowner to the buyer of the home for a period often (10) years. This warranty dogs not cover normal wear and tear,
smoke damage or damage caused by chimney fires, acts of God, or any product that was: (1) purchased other than from an authorized DuraVent dealer, retailer
or distributor; (2) modified or altered; (3) improperly serviced, inspected or cleaned; or (4) subject to negligence or any use iot in accordance with the printed
materials provided with the product as determined by DuraVent This limited lifetime warranty applies only to parts manufactured by DuraVent.
DuraVent provides the following warranties for its products: One Hundred Percent (100%) of the purchase price or MSRP at time of purchase, whichever is lower,
for 15 years from the date of purchase, and Fifty Percent (50%) thereafter, except for the following limitations: Ventinox linerand components in wood, oil, wood
pellet, and gas installations are warranted at One Hundred Percent (100%) for the lifetime of the original homeowner; Ventihox 316 liner and components for
coal burning installations which are warranted One Hundred Percent (100%) for ten years; all Termination Caps and DuraBlark® are warranted at One Hundred
Percent (100%) for five years, and atTen Percent (10%) thereafter.
All warranty obligations of DuraVent shall be limited to repair or replacement of the defective product pursuant to the terms and conditions applicable to each
product line. These remedies shall constitute DuraVenYs sole obligation and sole remedy under this limited warranty. This warranty provides no cash surrender
value. The terms and conditions of this limited lifetime warranty may not be modified, altered or waived by any action, inaction or representation, whether oral
or in writing, except upon the express, written authority of an executive officer of DuraVent
VENTINOX WARRANTY CONDITIONS
Liner and Component warranties contained herein are subject to the following conditions: (1) The Liner and Components rust be installed according to DV's
installation instructions; (2) The Liner and Components are used only to line or reline chimneys venting residential appliances for which the liner was intended;
and (3) documented annual inspection of the liner and Components and maintenance as deemed necessary, beginning ore year after the date of installation
and continuing throughout the warranty period, by a Nationally Certified Chimney Sweep orVENTINOX® installer. The Liner and Components warranty is further
subject to compliance with the following requirements throughout the warranty period: The chimney must have a chimney cap and chemical chimney cleaners
must not be used when cleaning the Liner or Components. Plastic -bristle flue cleaning brushes are recommended. Corn, bicfuels, driftwood or other wood
containing salt, preservative -treated lumber, plastic and household trash or garbage, or wood pellets containing such mate ials must not be burned in the
appliance or fireplace. In case of chimney fire, the chimney must be inspected and approved by a certified Chimney Sweep before reuse. After each annual
inspection, maintenance, and cleaning, the certified Chimney Sweep must fill out and date the appropriate section of the vlarranty card provided with the
chimney liner.
LIMITATIONS ON INTERNET SALES:
Notwithstanding any other terms or conditions of this limited lifetime warranty, DuraVent provides no warranty for the follcwing specific products if such
products are both: (a) purchased from an Internet seller, and (b) not installed by a qualified professional installer: DuraTecl , DuraPlus HTC*, PelletVent Pro®,
FasnSeal®, and DuraVent's relining products including DuraLiner®, DuraFlex° 304, DuraFlex® 316, DuraFlex° Pro, DuraFlee 5W, and Ventinox®. For purposes of
this warranty, a trained professional installer is defined as one of the following: licensed contractors with prior chimney installation experience, CSIA Certified
Chimney Sweeps, NFI Certified Specialists, orWETT Certified Professionals.
DuraVent reserves the right to inspect defective product to determine if it qualifies for replacement under the terms of this Imited lifetime warranty. All warranty
claims must be submitted with proof of purchase. labor and installation costs are not covered under this warranty. To obtin warranty service contact DuraVent
promptly at DuraVent Warranty Service, 902 Aldridge Rd., Vacaville CA 95688, or call 800-835-4429.
WHERE LAWFUL, DuraVent DISCLAIMS ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. IN NO EVENTWILL DuraVent BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR SPBCIAL DAMAGES OR DIRECT OR
INDIRECT LOSS OF ANY KIND, INCLUDING BUT NOT LIMITED TO PROPERTY DAMAGE AND PERSONAL INJURY. DuraVent'S EN -IRE LIABILITY IS LIMITED TO THE
PURCHASE PRICE OF THIS PRODUCT. SOME STATES DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES, OR THE EXCW-90N OR LIMITATION OF INCIDENTAL
OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TOYOU. THIS LIMITEDWAFRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
For the most up-to-date installation instructions, see www. duravent.com
REV 7.20.2010
M&G DuraVent, Inc PO Box 1510 Vacaville CA 95696-1510
Manufactured in Vacaville CA and Albany NY
DuraVent.
Member of & M&G Group
Customer Service Support 800-8354429 707-446-4740 FAX www.duravent.com
DuraTech is a registered trademark of the M&G DuraVent, Inc
All rights reserved. Made in the USA. M&G DuraVent is a member of M&G Group. 02011 L157 0412011