05-3816 (SOTB) Revision 1 Title 24
1 � I Revised Title 24 Energy Conservation Standards Compliance Report ANDALUSIA AT CORAL MOUNTAIN SALES CENTER LA QUINTA 1 Madlin s r en to nses Catherine M. Madlin, Certified Energy Analyst Post Office Box 1443 v Palm Springs, CA 92263 760-322-5004 / 323-3644 (fax) E-mail: CMadlin@aol.com Q� November 16, 2004 Job Number: 245 U, []O �I-WV M �Q0 Prepared For.- IS ®[ z cn CORAL OPTION 1, LLC. P.O. U-0,06 a 'd BOX 1716 ®o Cr M LA QUINTA, CA 92253 -� u. TELEPHONE (760) 777-7747 () m o Madlin s r en to nses Catherine M. Madlin, Certified Energy Analyst Post Office Box 1443 v Palm Springs, CA 92263 760-322-5004 / 323-3644 (fax) E-mail: CMadlin@aol.com Madlin s enterpfises Catherine M. Madlin, Certified Energy Analyst Y 760-322-5004 / 323-3644 (fax) ....... Title 24 Energy Conservation Standards Compliance Report This proposed project has been reviewed for compliance with the 2001 State of California Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design described in this compliance portfolio is in conformance with the standards as outlined in the attached compliance forms and documentation. Date: November 16, 2004 Job Number: 24545B Prepared For: CORAL OPTION 1, LLC. Project Name: ANDALUSIA AT CORAL MOUNTAIN SALES CENTER Project Location: LA QUINTA Method of Compliance: MICROPAS V6.1 CERTIFIED COMPUTER PROGRAM Certified Energy Analyst ' Catherine M. Madlin NR 98.90-544 r r �R98-9�0-144� r rCADEC California Association of Building Energy Consultants 1' ' v Post Office Box 1443 v Palm Springs, Ca 92263 • Madlin s enteiprises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) ....... >�ESCRI''�`ION':(3�'.. �CJ� � C+OMi��l�l'EN'�' 1VIIl�i C(31vZP.L7ANCE: �E �JiRR Job Name ANDALUSIA SALES CENTER /Job #24545B Method of Compliance Micropas V6.1 Computer Simulation Total Conditioned Square Footage 4998 Sq.Ft. Total Glazing % (Floor/Glass Area Ratio) 17.3% Insulation: Roof / Ceiling R-38 Batts Insulation: Walls R-19 Batt + 1" EPS R-3.9 or better R-19 Batt - 2x6 Firewall Insulation: Floor - Slab on Grade Not Required Insulation: H.V.A.C. Ducts/Location/Testing R-4.2 / Attic / No Duct Testing Required Glazing U Value / Type: Operable, Fixed, Casement Glazing SHGC 0.38, Dual Pane, Low E2, Any Frame Type 0.35 SHGC (NFRC Tested Values) Glazing U -Value / Type: French Doors Glazing SHGC 0.38, Dual Pane, Low E2, Any Frame Type 0.35 SHGC (NEMC Tested Values) Glazing U -Value / Type: Entry Door Surround Glazing Glazing SHGC 1. 19, Single Plan, Clear, Any Frame Type 0.83 SHGC (CEC Default Values) Glazing U -Value / Type: Skylights / Solar Tubes 1.72 Single Domed, Clear (CEC Default Values) Glazing Exterior Shading Overhangs As Shown Thermal Mass Square Footage & % Not Required H.V.A.C. System Type Main Bldg: Gas Heat / Electric AC Split Systems / Multiple Units Detached Bldg: (1) Heat Pump / Split System HVAC System Efficiencies (heating/cooling) Main Bldg: 78% AFUE / 12.0 SEER Detached Blgd: 8.0 HSPF / 12.0 SEER TX Valve Required - All Units Domestic Hot Water Heater Main Bldg: (1) 100 Gallon Gas with Recirc. Detached: (1) 30 Gallon Standard Distribution Energy Factor / Eff. / Standby Loss Large: 0.78 RE / Small: 0.58 EF or better R12 Blanket on Tank No Recirculating Pump for DHW Yes - 100 Gallon with Time & Temp Controls Other Requirements TApplicable Mandatory Measures v Post Office Box 1443 v Palm Springs, Ca 92263 v Madlin s enter uses Catherine M. Madlin, Certified Energy Awlyst v 760-322-5004 / 323-3644 (fax) v v v v v v v Title 24 Compliance Forms CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 Project Address........ SALES OFFICE ******* ANDALUSIA, LA QUINTA *v6.01* --------------------- Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises ' P.O. Box 1443 Palm Springs, CA 92262 Plan Check Date Climate Zone........... 760-322-5004 15 Field Che -c- ------------- Date Compliance_ MICROPAS6 Method ...... v6.01 User#-MP0207 -MICROPAS6-v6_01- for -2001- Standards -by-Enercomp,- Inc. --- File -24545B1 Wth-CTZ15S92 Program -FORM CF -1R User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned ------------------- Floor Area..... 4998 sf Building Type .............. Single Family Detached Construction Type ......... New Building Number of Front Orientation. Cardinal - N,E,S,W Dwelling Units... 1 ' Number of Stories........ 1 Floor Construction Type.... Slab On Grade ' Glazing Percentage......... Average Glazing 17.3 % of floor U -factor... 0.4 Btu/hr-sf-F area Average Glazing SHGC....... 0.36 ' Average Ceiling Height..... 10.9 ft BUILDING SHELLINSULATION Component Type Wall Frame Type Wood - - Cavity Sheathing Total Assembly R -value R -value R -value U -factor -------------- ------------------------ R-17.8 R-3.9 R-21.7 0.051 Location/Comments Wall Wood R-17.8 R-0 R-17.8 0.064 ' Door RoofRadiant None Wood R-0 R-0 R-0 0.330 R-11 R-27 R-38 0.025 SlabEdge None R-0 R-0 F2=0.760 SlabEdge None R-0 R-0 F2=0.510 FENESTRATION ------------ Over- ' Orientation--------- Area U- Interior (sf) Factor SHGC Shading Exterior Shading------- hang/ Fins ---------- Window Back (S) ----- ------ -------------- ------- 15.0 0.380 0.350 Standard Standard --- None Door Window Back (S) Left (E) 48.0 0.380 0.350 Standard 12.0 0.380 0.350 Standard Standard Standard Yes Yes Door Left (E) 48.0 0.380 0.350 Standard Standard Yes Window Back (S) 12.0 0.380 0.350 Standard Standard Yes Door Window Back (S) Back (S) 48.0 0.380 0.350 Standard 12.0 0.380 0.350 Standard Standard Standard Yes Yes Door Back (S) 48.0 0.380 0.350 Standard Standard Yes Window Back (S) 12.0 0.380 0.350 Standard Standard Yes Door Back (S) 48.0 0.380 0.350 Standard Standard Yes ' Door Left (E) 48.0 0.380 0.350 Standard Standard Yes Window Back (S) 12.0 0.380 0.350 Standard Standard Yes Window Window Back (S) Back (S) 24.0 0.380 0.350 Standard 12.0 0.380 0.350 Standard Standard Standard Yes Yes CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MIUser#SMP020701 92 OPE ------------------------------------------------------------------------------- User-MadlinB s EnterprisesRun-PC.RESPRMIT.CALC FENESTRATION ------------ Over- Area U- Interior Exterior hang/ ' Orientation (sf) Factor SHGC Shading Shading Fins -------------------- Window Right (W) ----- 15.0 ------ 0.380 ------ 0.350 --------------- Standard -------------- Standard ----- None Window Right (W) 15.0 0.380 0.350 Standard Standard None Window Right (W) 15.0 0.380 0.350 Standard Standard None Window Right (W) 15.0 0.380 0.350 Standard Standard None Window Window Right Right (W) (W) 15.0 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None Yes Window Right (W) 4.5 0.380 0.350 Standard Standard Yes Window Right (W) 15.0 0.380 0.350 Standard Standard None Window Window Right Right (W) (W) 10.0 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Window Right (W) 4.5 0.380 0.350 Standard Standard None Window Right (W) 4.5 0.380 0.350 Standard Standard None ' Window Window Left Left (E) (E) 20.0 15.0 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Window Left (E) 15.0 0.380 0.350 Standard Standard None Door Front (N) 48.0 0.380 0.350 Standard Standard None ' Window Window Front Front (N) (N) 4.5 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Window Front (N) 4.5 0.380 0.350 Standard Standard None Window Front (N) 4.5 0.380 0.350 Standard Standard None ' Window Window Left Left (E) (E) 15.0 15.0 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Window Left (E) 15.0 0.380 0.350 Standard Standard None Window Left (E) 15.0 0.380 0.350 Standard Standard None ' Window Window Left Left (E) (E) 15.0 15.0 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Door Right (W) 48.0 0.380 0.350 Standard Standard None Window Front (N) 15.0 0.380 0.350 Standard Standard None ' Window Window Left Left (E) (E) 4.5 4.5 0.380 0.380 0.350 0.350 Standard Standard Standard Standard None None Window Left (E) 9.0 0.380 0.350 Standard Standard None Window Left (E) 4.5 0.380 0.350 Standard Standard None ' Window Skylight Left Horz (E) 4.5 1.1 0.380 1.720 0.350 0.830 Standard None Standard None None None Skylight Horz 1.1 1.720 0.830 None None None Skylight Horz 1.1 1.720 0.830 None None None Skylight Horz 1.1 1.720 0.830 None None None Window Front (N) 19.0 1.190 0.830 Standard Standard None Door Left (E) 24.0 0.380 0.350 Standard Standard None 'SLAB SURFACES Area Slab Type (sf) -------- ------ Standard Slab 4443 Standard Slab 555 ' CERTIFICATE -OF- COMPLIANCE: -RESIDENTIAL --------------------Page -3-------_--CF_1R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- ' I MIUser#SMP020701 User-MadlinBs Enterprises92Run-PCrRESPOPERMIT1CALC ------------------------------------------------------------------------------- This building incorporates either Tested Refrigerant Charge and Airflow (RCA) ' or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates.non-standard Water Heating System HVAC SYSTEMS ------------ Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat ' Type Efficiency Airflow Location R -value Leakage D Type ------------ Furnace -------------------------------------------- ------ 0.780 AFUE n/a Attic R-4.2 No No ---------- Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback ' HPSplit 8.00 HSPF n/a Attic R-4.2 No No Setback HPSplitTXV 12.00 SEER Yes Attic R-4.2 No No Setback WATER HEATING SYSTEMS --------------------- Number Tank External in Energy Size Insulation ' Tank Type ------------ Heater Type Distribution Type System Factor (gal) ----------- ------------------- R -value DHW 1 -------------- ------ ---------- ' Large DHW 2 Gas Recirc/TimeTemp 1 n/a 100 R-0 Storage Gas Standard 1 0.58 30 R- n/a WATER -HEATING -SYSTEMS -DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System ----- -Efficiency ---Input---- Fraction---R_value ---- Light DHW 1 Large 0.78 n/a 0.03 R-n/a 0 ' SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** ' *** installed to manufacturer and CEC specifications, and *** verified during plan check and field inspection. *** *** This is a multiple orientation building with no orientation restrictions. ' This printout is for the front facing North. . This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, ' and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) ' or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates.non-standard Water Heating System ' CERTIFICATE -OF- COMPLIANCE: -RESIDENTIAL --------------------Page -4----------CF_1R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 6 v6. File-245451 Wth-CTZ15S MIUser#SMP020071 User-MadlinBs Enterprises92Run-PC.RESPOPERMIT.CALC ------------------------------------------------------------------------------- ' HERS REQUIREDVERIFICATION -------------------------- - *** Items in this section require field testing and/or *** ' *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF -6R installation certificate. *** ' This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification ' is not necessary for the RCA or TXV. REMARKS The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, ' people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing hvac contractor shall provide the required CF -6R ' with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the ' HVAC system. The installed plumber shall provide the required CF- 6R listing the water heater model number(s) and certified plumbing ' fixtures. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF -1R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 6 v6. ' I MIUser#SMP020071 UsereMadlinBs Enterprises92Run-PC.RESPOPERMIT.CALC ------------------------------------------------------------------------------- ' 'COMPLIANCE STATEMENT - This certificate of compliance lists the building features and performance ' specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... Name ' Company. CORAL OPTION 1, LLC Co Address. P.O. BOX 1716 LA QUINTA CA 92253 Phone... 7 0- -7 7 e... License. Signed.. (i' Signed.. teI ENFORCEMENT AGENCY Name.... ' Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR CATHERINE M. MADLIN Madlin's Enterprises P.O. Box 1443 Palm Springs, CA 92262 760-322-5004 (date) ofd Certified Energy Analyst Catherine M. Madlin NR 98-90-544 r r R 98-90-144 rr C A B E C Colifomia Association of DuildkV EAeWC&w#a s MANDATORY -MEASURES -CHECKLIST: _RESIDENTIAL -----------------Page -1-_--------MF_1R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 Project Address........ SALES OFFICE ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises ' P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method ...... MICROPAS6 -------------------- ComplianceMethod______MICROPAS6v6_01- for -2001- Standards -by-Enercomp,- Inc. _~- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ' ---------------7--------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an ' asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether ' they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. V-1 150(b): Loose fill insulation manufacturer's labeled R -Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). ✓ *150(d): Minimum R-13 raised floor insulation.in framed floors. ' 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls ' 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain ' Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints - K — and penetrations caulked and sealed. 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 -meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances ' and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control ' c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ✓ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 150(1): Setback thermostat on all applicable heating and/or cooling systems. ' 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber addhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. V 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning 'MANDATORY -MEASURES -CHECKLIST: -RESIDENTIAL-----------------Page _3-_---_----MF_1R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ' I MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC , ------------------------------------------------------------------------------- ' pilot light (Exception: Non -electrical cooking appliances ✓ with pilot < 150 Btu/hr). LIGHTING MEASURES ----------------- ' Design- Enforce- er ment 150(k)l: Luminaires for general lighting in kitchens shall ' have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ' 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement ' allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 1 COMPUTER METHOD SUMMARY Page 1 C -2R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 Project Address........ SALES OFFICE ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin = = Space Heating.......... 4.43 4.02 0.41 = = Space Cooling.......... 36.54 31.06 5.48 = = Water Heating.......... 5.70 8.48 -2.78 = = North Total 46.67 43.56 3.11 = = Space Heating.......... 4.43 3.71 0.72 = _. Space Cooling.......... 36.54 30.18 6.36 = = Water Heating.......... = East Total ---5.70- 46.67 -------- 42.37 -------- 4.30 = = Space Heating.......... 4.43 3.78 0.65 = = Space Cooling.......... 36.54 31.57 4.97 = = Water Heating.......... 5.70 8.48 -2.78 = South Total ------ 46.67 -------- 43.83 -------- 2.84 = Space Heating.......... 4.43 3.77 - 0.66 = = Space Cooling.......... 36.54 30.18 6.36 = = Water Heating ..........5 .70 8.48 -2.78 _ = West Total ------- 46.67 -------- 42.43 -------- _ 4.24 = ***-Building -complies -with -Computer -Performance -*** GENERAL INFORMATION Conditioned Floor Area..... 4998 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13.54.42 --------------------------------------------------------- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- Conditioned Volume......... 54566 cf Slab -On -Grade Area......... 4998 sf Glazing Percentage......... 17.3 % of floor area Average Glazing U -factor... 0.4 Btu/hr-sf-F Average Glazing SHGC....... 0.36 Average Ceiling Height..... 10.9 ft BUILDING ZONE INFORMATION OPAQUE SURFACES --------------- Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments -------------- ------ ----- ----- --- ---- ----------------- ---------------- 1.ZONE 1 Floor 425 # of 21.7 0 Vent Vent Air 3 Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type -------------- (sf) ----- (cf) ------- Units ----- itioned ------- Type (ft) (sf) Credit 1.ZONE Wall 1008 0.051 21.7 ----------- ----- -------- --------- Residence 4443 49016 0.89 Yes Setback 2.0 Standard No 2.ZONE Wall 83 0.051 21.7 45 90 Yes W.17.8.PW2X6 Residence 555 5550 0.11 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments -------------- ------ ----- ----- --- ---- ----------------- ---------------- 1.ZONE 1 Wall 425 0.051 21.7 0 90 Yes W.17.8.PW2X6 3 Wall' 902 0.051 21.7 90 90 Yes W.17.8.PW2X6' 5 Wall 517 0.051 21.7 180 90 Yes W.17.8.PW2X6 7 Wall 1008 0.051 21.7 270 90 Yes W.17.8.PW2X6 9 Wall 230 0.064 17.8 0 90 No W.19.2X6FIRE 11 Wall 83 0.051 21.7 45 90 Yes W.17.8.PW2X6 12 Wall 150 0.051 21.7 135 90 Yes W.17.8.PW2X6 13 Wall 205 0.051 21.7 315 90 Yes W.17.8.PW2X6 14 Door 20 0.330 0 0 90 Yes None 16 RoofRadiant 4438 0.025 38 n/a 0 Yes R.38.2X4.24 2.ZONE 2 Wall 180 0.051 21.7 0 90 Yes W.17.8.PW2X6 4 Wall 316 0.051 21.7 90 90 Yes W.17.8.PW2X6 6 Wall 150 0.051 21.7 180 90 Yes W.17.8.PW2X6 8 Wall 283 0.051 21.7 270 90 Yes- W.17.8.PW2X6 10 Wall 65 0.064 17.8 0 90 No W.19.2X6FIRE 15 Door 24 0.330 0 270 90 Yes None 17 RoofRadiant 555 0.025 38 n/a 0 Yes R.38.2X4.24 PERIMETER LOSSES Length ---------------- F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ ------ 1.ZONE -------- ------- ----- ---------------------- 18 SlabEdge 345 0.760 R-0 No 20 SlabEdge 23 0.510 R-0 No 2.ZONE 19 SlabEdge 105 0.760 R-0 No 21 SlabEdge 7 0.510 R-0 No COMPUTER -METHOD -SUMMARY -----------------------------------Page -3-----------C_2R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Program-FC-2 ' MIUser#SMP020701 User-MadlinBs Enterprises92Run-PC.RESPOPERMITRCALC ------------------------------------------------------------------------------- 'FENESTRATIONSURFACES �1 Orientation ----------- 1. ZONE 1 Window 2 Door 3 Window 4 Door 5 Window 6 Door 7 Window 8 Door 9 Window 10 Door 11 Door 12 Window 13 Window 14 Window 15 Window 16 Window 17 Window 18 Window 19 Window 20 Window 21 Window 22 Window 23 Window 24 Window 25 Window 26 Window 27 Window 28 Window 29 Window 30 Door 31 Window 32 Window 33 Window 34 Window 35 Window 36 Window 37 Window 38 Window 39 Window 40 Window 48 Skylight 49 Skylight 50 Skylight 51 Skylight 52 Window 53 Door 2.ZONE 41 Door 42 Window 43 Window Area U- Act Exterior Shade Interior Shade (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC Back (S) 15.0 0.380 0.350 180 90 Back (S) 48.0 0.380 0.350 180 90 Left (E) 12.0 0.380 0.350 90 90 Left (E) 48.0 0.380 0.350 90 90 Back (S) 12.0 0.380 0.350 180 90 Back (S) 48.0 0.380 0.350 180 90 Back (S) 12.0 0.380 0.350 180 90 Back (S) 48.0 0.380 0.350 180 90 Back (S) 12.0 0.380 0.350 180 90 Back (S) 48.0 0.380 0.350 180 90 Left (E) 48.0 0.380 0.350 90 90 Back (S) 12.0 0.380 0.350 180 90 Back (S) 24.0 0.380 0.350 180 90 Back (S) 12.0 0.380 0.350 180 90 Right (W) 15.0 0.380 0.350 270 90 Right (W) 15.0 0.380 0.350 270 90 Right (W) 15.0 0.380 0.350 270 90 Right (W) 15.0 0.380 0.350 270 90 Right (W) 15.0 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 15.0 0.380 0.350 270 90 Right (W) 10.0 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Right (W) 4.5 0.380 0.350 270 90 Left (E) 20.0 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Front (N) 48.0 0.380 0.350 0 90 Front (N) 4.5 0.380 0.350 0 90 Front (N) 4.5 0.380 0.350 0 90 Front (N) 4.5 0.380 0.350 0 90 Front (N) 4.5 0.380 0.350 0 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Left (E) 15.0 0.380 0.350 90 90 Horz 1.1 1.720 0.830 0 0 Horz 1.1 1.720 0.830 0 0 Horz 1.1 1.720 0.830 0 0 Horz 1.1 1.720 0.830 0 0 Front (N) 19.0 1.190 0.830 0 90 Left (E) 24.0 0.380 0.350 90 90 Right (W) 48.0 0.380 0.350 270 90 Front (N) 15.0 0.380 0.350 0 90 Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 None/1 None/l None/1 None/l Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 None/1 None/1 None/1 None/l Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 COMPUTER METHOD SUMMARY Page 4 C -2R ------------------------------------------------------------------------------- Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MIUser#SMP020701 User-MadlinBs Enterprises92Run-PC.RESPOPERMITRCALC ------------------------------------------------------------------------------- FENESTRATION SURFACES OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Refrigerant Area Tested Area U- System Act Rght Exterior Shade Interior Shade Orientation Type Efficiency Airflow Location (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC 44 Window Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 45 Window Left (E) 9.0 0.380 0.350 90 90 Standard/0.76 Standard/0.68 46 Window Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 47 Window Left (E) 4.5 0.380 0.350 90 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ----- -.ZONE Standard Slab 4443 2.ZONE Standard Slab 555 HVAC SYSTEMS Refrigerant Area Tested ACCA System Left Rght Duct Manual Duct Type Efficiency Airflow Location R -value Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 1.ZONE ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 2.ZONE HPSplit 2 Door 48.0 6 8 29.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 12.0 6 2 16 0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 48.0 6 8 16 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 12.0 6 2 17.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Door 48.0 6 8 17.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 12.0 6 2 17.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Door 48.0 6 8 17.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 12.0 6 .2 17.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 10 Door 48.0 6 8 17.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 11 Door 48.0 6 8 43 2 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 12.0 2 6 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 24.0 4 6 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 12.0 2 6 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 4.5 1.5 3 6 2 n/a n/a n/a n/a n/a n/a n/a n/a 21 Window 4.5 1.5 3 6 2 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ----- -.ZONE Standard Slab 4443 2.ZONE Standard Slab 555 HVAC SYSTEMS Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R -value Leakage D Eff ------------- 1.ZONE ------------------------------- ------- --------- -------- ---- Furnace 0.780 AFUE n/a Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 2.ZONE HPSplit 8.00 HSPF n/a Attic R-4.2 No No 0.772 HPSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 COMPUTER METHOD SUMMARY Page 5 C -2R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- WATER HEATINGSYSTEMS - - Number in Tank Type Heater Type Distribution Type System ------------ ----------- ------------------- ------ DHW 1 1 Large Gas Recirc/TimeTemp 1 DHW 2 2 Storage Gas Standard 1 Tank External Energy Size Insulation Factor (gal) R -value -------- ---------------- WATER HEATING SYSTEMS DETAIL n/a 100 R-0 0.58 30 R- n/a Standby Internal Tank Recovery Rated Loss Insulation Pilot System----- -Efficiency Input Fraction R -value----- -Light DHW 1 1 Large 0.78 n/a 0.03 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. ' This printout is for the front facing North. t This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) ' or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION -------------------------- ' *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** ` *** must be reported on the CF -6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. t ' COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 6 v6. File-245451 Wth-CTZ15S Program-FC-2 ' I MIUser#SMP020071 User-MadlinBs Enterprises92Run-PC.RESPOPERMITRCALC ------------------------------------------------------------------------------- REMARKS The values and materials used in this compliance portfolio are ' the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his/her option) install better materials without additional compliance calculations. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in ' accordance with industry standards. The load calculation in this report considers ambient temperature loads, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and ' system/equipment performance. The installing hvac contractor shall provide the required CF -6R with the installed hvac equipment model numbers. A night setback thermostat is required to be installed with the HVAC system. ' The installed plumber shall provide the required CF -6R listing the water heater model number(s) and certified plumbing fixtures. l� ' CONSTRUCTION ASSEMBLY Page 1 3R Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13.54.42 ------------------------------------------------------------------------------- CROPA6 v6. ------------------------------------------------------------------------------- File-245451 Wth-CTZ15S Program-F3R ' I MlUser#SMP020071 User-MadlinBs Enterprises92Run-PC.RESPOPERMIT.CALC ------------------------------------------------------------------------------- --------------------------------- Parallel Path Method Reference Name . W.17.8.PW2X6 Description .... Wall R-19 w/3.90 EPS Type ........... Wall R -Value ........ 21.7 Hr-sf-F/Btu Framing Material ..... FIR.2X6 Type ......... Wood Description .. 2x6 fir Spacing ...... 16 inches on center Framing Frac.. 0.15 --------------------------------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS FRAMING ADJUSTMENT CALCULATION Cavity Frame R -Value R -Value 0.17 Material 0.17 0.17 Name Description O. ------------- FILM.EX ---------------------------------------- Exterior air film: winter value 1. STUCCO.0.88 0.875 in stucco 2. EPS.3.9 1.00 in polystryene 3.c. BATT.R19 R-19 batt insul (cavity = 5.5 in) 3f. FIR.2X6 2x6 fir 4. GYP.0.50 0.50 in gypsum or plaster board I. FILM.IN.WLL Inside air film: heat sideways Total Unadjusted R -Values FRAMING ADJUSTMENT CALCULATION Cavity Frame R -Value R -Value 0.17 0.17 0.17 0.17 3.90 3.90 17.80 -- -- 5.45 0.45 0.45 0.68 0.68 23.17 10.82 Cavity Framing Total ------------------------------------------------------ U-Factor: (1 / 23.17 x 0.85) + (1 / 10.82 x 0.15) = 0.051 Btu/hr-sf-F II Total R -Value: 1 1 / 0.051 = 19.79 hr-sf-F/Btu Madlin s en terprises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) S ... V ® V H. V.A. C. Load Calculation HVAC SIZING Page 1 HVAC ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 Project Address........ SALES OFFICE ******* --------------------- ANDALUSIA, LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -HVAC SIZING ` User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- GENERAL INFORMATION --------------- Floor Area ................. 4998 sf ' Volume.. .. 54566 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ INDIO Latitude... .. ........ 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ..... ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 1 1 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description (Btuh) (Btuh) -------------------------------------------- Opaque Conduction and Solar...... 29811 ----------- 10834 Glazing Conduction ............... 14342 11894 Glazing Solar .................... n/a 19631 Infiltration ..................... 32175 19068 Internal Gain .................... n/a 4788 Ducts. ... ......... 7633 6621 Sensible Load .................... 83962 72836 ' Latent Load ...................... n/a _--14567- Minimum Total Load 83962 87404 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all ' factors when selecting the HVAC equipment. 1 1 7 HVAC SIZING Page 2 HVAC Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- -MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' FloorArea ....................... 4443 sf Volume........................... 49016 cf ZONE '2.ZONE' Floor Area ....................... Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 23412 ----------- 8617 Glazing Conduction ............... 12940 10731 Glazing Solar .................... n/a 17252 Infiltration....... ............ 28903 17129 Internal Gain .................... n/a 4673 Ducts ............................ 6525 5840 Sensible Load .................... 71780 64241 Latent Load ...................... n/a 12848 Minimum Zone Load ----------- 71780 ----------- 77089 ZONE '2.ZONE' Floor Area ....................... 555 sf Volume........................... 5550 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 6400 ----------- 2217 Glazing Conduction.......... ... 1402 1163 Glazing Solar .................... n/a 2379 Infiltration ..................... 3273 1939 Internal Gain .................... n/a 116 Ducts ............................ 1107 781 Sensible Load .................... 12182 8595 Latent Load ...................... n/a 1719 Minimum Zone Load 12182 10314 GENERAL INFORMATION ------------------- Floor Area ................. 4998 sf Volume.. .... ............ 54566 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ INDIO Latitude... .. ....... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY HVAC SIZING Cooling Page 3 HVAC (Btuh) - - -- --- Project Title.......... ANDALUSIA.SALES.CENTER -- - - Date..11/16/04 13:54:42 ' I MICROPAS6 v6.01 User#-MP0207 ------------------------------------------------------------------------------- File -24545B1 Wth-CTZ15S92 User-Madlin's Enterprises Program -HVAC SIZING - Run-PC.RESP.PERMIT.CALC GENERAL INFORMATION ------------------- Floor Area ................. 4998 sf Volume.. .... ............ 54566 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ INDIO Latitude... .. ....... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range. ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. [1, 1 Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 29811 ----------- 10834 Glazing Conduction ............... 14342 11894 Glazing Solar .................... n/a 18418 Infiltration ..................... 32175 19068 Internal Gain .................... n/a 4788 Ducts. ..... ................... 7633 6500 Sensible Load .................... 83962 71502 Latent Load ...................... n/a 14300 Minimum Total Load ----------- 83962 ----------- 85803 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. [1, 1 HVAC SIZING Page 4 HVAC Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- ' HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ' ZONE '1.ZONE' Floor Area ....................... 4443 sf Volume ........................... 49016 cf Heating Cooling Description (Btuh) (Btuh) ' --------------------------------- Opaque Conduction and Solar...... ----------- 23412 ----------- 8617 Glazing Conduction .............. 12940 10731 Glazing Solar .................... n/a 17300 ' Infiltration .................... Internal Gain.. 28903 n/a 17129 4673 Ducts. 6525 5845 tLatent Sensible Load .................... Load ...................... 71780 n/a 64294 12859 ' Minimum Zone Load ZONE 12.ZONE' 71780 77153 ' Floor Area ....................... Volume ........................... 555 sf 5550 cf ' Description Opaque Conduction and Solar...... Heating (Btuh) 6400 Cooling (Btuh) 2217 Glazing Conduction ............... 1402 1163 ' Glazing Solar .::::::::::::::::::. Infiltration.. n/a 3273 1118 1939 Internal Gain .................... n/a 116 Ducts ............................ 1107 655 Sensible Load .................... 12182 7208 Latent Load ...................... n/a 1442 Minimum Zone Load ----------- 12182 ----------- 8650 1 ' HVAC SIZING' ----------------Page-S-----------HVAC Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ' ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MIUser#SMP020701 I User-MadlinBs Enterprises92Run-PCrRESPVPERMITICALC ' ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 4998 sf Volume ............::::::::: 54566 cf ' Front Orientation. Front,Facing 180 deg (S) Sizing Location............ INDIO Latitude. .... ....... 33.7 degrees Winter Outside Design...... 29 F ' Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range......--- 30 F ' Interior Shading Used.. No Exterior Shading Used...... No ' Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY t-------------------------------- I Heating Cooling Description (Btuh) --------------------------------- (Btuh) - ' ----------- Opaque Conduction and Solar:::::: 29811 Glazing Conduction.. 14342 ----------- 10834 11894 • • Glazing Solar.. n/a 18461 Infiltration ..................... 32175 19068 .' Internal Gain :::::::::::::::::::: 633 n/a Ducts. 7633 4788 6504 Sensible Load.. 83962 71549 Latent Load ...................... n/a 14310 1 ----------- Minimum Total Load 83962 ----------- 85859 Note: The loads shown are only one of the criteria affecting the selection ' of HVAC equipment. Other relevant design factors requirements, outside air, outdoor design temperatures, such as air flow coil sizing, availability of equipment, oversizing safety margin, considered. It is the HVAC designer's responsibility factors when selecting the HVAC equipment. etc., must also be to consider all ' HVAC SIZING----------------------------Page-6-----------HVAC Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 6 v6. File-245451 wth-CTZ15S ' I MIUser#SMP020071 User-MadlinBs Enterprises92Run-PC.RESPVPERMITICALC ------------------------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE '1.ZONE' Floor Area ....................... 4443 sf Volume........................... 49016 cf Sensible Load .................... 71780 Latent Load ...................... n/a Minimum Zone Load 71780 ZONE '2.ZONE' FloorArea ....................... 555 sf Volume ........................... 5550 cf Cooling (Btuh) 8617 10731 15975 17129 4673 5712 62836 12567 75404 Heating Description --------------------------------- (Btuh) Opaque Conduction and Solar...... ----------- 23412 Glazing Conduction................ 12940 GlazingSolar .................... n/a Infiltration... ................ 28903 Internal Gain .................... n/a Ducts............................ 6525 Sensible Load .................... 71780 Latent Load ...................... n/a Minimum Zone Load 71780 ZONE '2.ZONE' FloorArea ....................... 555 sf Volume ........................... 5550 cf Cooling (Btuh) 8617 10731 15975 17129 4673 5712 62836 12567 75404 Heating Cooling Description --------------------------------- (Btuh) (Btuh) ----------- Opaque Conduction and Solar...... 6400 ----------- 2217 Glazing Conduction ............... 1402 1163 Glazing Solar .................... n/a 2486 Infiltration ..................... 3273 1939 Internal Gain .................... n/a 116 Ducts ............................ 1107 792 Sensible Load .................... 12182 8712 Latent Load ...................... n/a 1742 ----------- Minimum Zone Load 12182 ----------- 10455 HVAC 'SIZING Page 7 HVAC ------------------------------------------------------------------------------- Project Title.......... ANDALUSIA.SALES.CENTER Date..11/16/04 13:54:42 --------------------------------------------------------- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC ------------------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 4998 sf Volume.. .... ............ 54566 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude... .... ........ 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range........ ..... 30 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar:..... ----------- 29811 ----------- 10834 Glazing Conduction ............... 14342 11894 Glazing -Solar .................... n/a 17507 Infiltration ..................... 32175 19068 Internal Gain .................... n/a 4788 Ducts. .... ................... 7633 6409 Sensible Load .................... 83962 70499 Latent Load ...................... n/a 14100 Minimum Total Load ----------- 83962 ----------- 84599 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... ANDALUSIA.SALES.CENTER Date. .11/16/04 13:54:42 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS6 v6.01 File -24545B1 Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-PC.RESP.PERMIT.CALC -------------=----------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE.'1.ZONE' Floor Area....... .............. 4443 sf Volume ............................ 49016 cf Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 23412 ----------- 8617. Glazing Conduction ............... 12940 .10731 Glazing Solar .................... n/a 16239 Infiltration ..................... 28903 17129 Internal Gain .................... n/a 4673 Ducts ............................ 6525 5739 Sensible Load .................... 71780 63127 Latent Load ...................... n/a 12625 Minimum Zone Load ----------- 71780 ----------- 75752 ZONE 12.ZONE' Floor Area ....................... 555 sf Volume ........................... 5550 cf Heating Cooling Description (Btuh) (Btuh) --------------------------------- Opaque Conduction and Solar...... ----------- 6400 ----------- 2217 Glazing Conduction ............... 1402 1163 Glazing Solar .................... n/a 1267 Infiltration ..................... 3273 1939 Internal Gain .................... n/a 116 Ducts ............................ 1107 670 Sensible Load .................... 12182 7372 Latent Load ...................... n/a 1474 Minimum Zone Load ----------- 12182 ----------- 8847 Madlin s en terpfises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) v .... v v Addendums and Notes I ! Madlin's 1 ente fises . � Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 1323-3644 (fax) ....... 1 11 Title 24 Building Energy Efficiency Standards Residential Manual Excerpt RADIANT BARRIERS Introduction A radiant barri heat. Aluminui Installation of although they emjss,ion of radiant f!u�( t a material. c©,oli�g season, The Commission has approved an energy credit for radiant barriers meeting specific eligibility and installation criteria. The radiant barrier energy credit is an adjustment to the ceiling U -value when the ceiling is adjacent to an attic with a radiant barrier. The credit is automatically applied by modeling a radiant barrier in an approved computer program with this optional capability. Construction Below are the parameters for receiving credit for a radiant barrier, including criteria for the installation, ventilation and material, all of which contribute to the performance of the radiant barrier. Installation Installation must be in conformance with ASTM C-1158-97 (Standard Practice for Use and Installation of Radiant Barrier Systems (RBS) in Building Construction.), ASTM C -727- 90(1996)e1 (Standard Practice for Installation and Use of Reflective Insulation in Building ConstrluctioT.), ASTM C-1.13-975 (Standard Specification for Sheet radiant Barriers for Building Construction Appliations), and ASTM C-1224-99 (Stangard Specification for Reflec iue Insuapp-n-,for Bji ding A lications ark radiant barrier must be securely i stalled in a gerrar:ders ni rrlan er witF1-th s in ide {acing o t mrd t a i �oor/Pf-th,�,fold I(( I I I (� Radia t u t e ins tall d e o f tr s a rs o cods n n . n... ( P9 1. Draped over the truss/rafter ( the top chord) before the upper roof deck is installed. 2. Spanning between the truss/rafters (top chords) and secured (stapled) to each side. 3. Secured (stapled) to the bottom surface of the truss/rafter (top chord). A minimum air space must be maintained between the top surface of the radiant barrier and roof decking of not less than 1.5 inches at the center of the truss/rafter span. • P.O. Box 1443 • Palm Springs, Ca 92263-1443 Y E-mail: Cmadlin@aoI.com • 1 It Madlin's Enterprises — Addendums & Notes ' 4. Attached [laminated] directly to the underside of the roof decking. The radiant barrier must be laminated and perforated by the manufacturer to allow moisture/vapor transfer through the roof deck. The radiant barrier must be installed to cover all gable end walls and other vertical surfaces in the attic. ' Ventilation The attic must be %Ae ntilated to: O 1. Conform to rnaA 1ah.t� rer' 'n'strr�ct'ons. 2. Provide a i►jimw fir entilador�Greao n t lesPttha4nuare foot f ent area for it - each 150 s t]are�feet�of att�c{ouir'area� U 3. Provide no less than 30 percent upper vents. (Ridge vents or gable end vents are recommended to achieve the best performance. The material should be cut to allow for full air flow to the venting.) The radiant barrier (except for radiant barriers laminated directly to the roof.deck) must be installed to: 1. Have a minimum gap of 3.5 inches between the bottom of the radiant barrier and the top of the ceiling insulation to allow ventilation air to flow between the roof decking and the top surface of the radiant barrier. 2. Have a minimum of six (6) inches (measured horizontally) left at the roof peak to allow hot air to escape from the air space between the roof decking and the top surface of the radiant barrier. When installed in enclosed rafter spaces where ceilings are applied directly to the underside of roof rafter minimum ai space of 1 inch must be provided between the radiant barrier and the to f the ceiling insul tion, and ventilation must be providedpor each rafter space. Vents must 4e proved b hth ype n to e�, endsof-b a enclosed aftyPac Emissive • The emissivity of the radiant barrier must b le than or equal to 0.05as tested in accordance with ASTM C-1371-98 or ASTM -E408 -7(1996)e1. • The product must meet all requirements for California certified insulation material [radiant barriers] of the Department of Consumer Affairs, Bureau of Home Furnishings and Thermal Insulation. Madlin's Enterprises — Addendums & Notes Note: Aluminum will deteriorate or corrode in the presence of alkaline materials. Unless the aluminum foil is protected by waterproofed paper or plastic coating, keep it from coming into direct contact with anything alkaline, such as masonry surfaces. Inspection If a radiant barrier was used for compliance credit, check the installation guidelines provided above for the builder. Especially critical are the ventilation and air space requirements that enable the radiant barrier to perform as expected. v A CEC Title 24 Fesitfen ial Design Manual 001 -Cod Figure 3-2: Methods ' r nstallatio f r�Ra iant �rri rs U U u . UU � Roof Decking Roof Decking Air SpaceRafter f= Air Space P s Rafter Radiant Radiant Bamer r Barrier Insulation _t Insulation Joist b ' { Joist Ir-- ,/y., € %Y3S:ti?Y Maly Method 1: Radiant Barrier Draped Method 2: Radiant Barrier Attached Over Top of Truss/Rafter Between Truss/Rafters Roof Decking Roof Decking Air Space Rafter Rafter Radiant Radiant Barrier Barrier r Insulation Insulation yy { lYe"1i .y�S i P��4 Joist s` � i .9 }hlpt•,j5[21 .r$,Zje .i Joist � x�,-" Method 3: Radiant Barrier Attached to Method 4: Radiant Barrier Attached to Bottom of Truss/Rafter Underside of Roof Deck i l� ii Madlin-'s enterprises Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) .... V .. Title 24 Building Energy Efficiency Standards Residential Manual Excerpt THERMOSTATIC EXPANSION VALVES Thermostatic expansion valves (TXVs) or an equivalent alternative approved by the Commission are required for split system central air conditioners in some compliance methods and calculations. I:#`T s�,are required for complia ice field verification (W§ual confirmation) by a certified HERS rater, i equired. i I �' r l I J HERS Raters Approved HERS -raters conduct#'h'e-fieldwerrfication diagnostic testing and inspections, and provide Certificate of Field Verification and Diagnostic Testing (CF -4R) forms or notification that corrective actions are needed. HERS raters must be independent of both the builder and sub- contractor who installed the duct systems being field verified, and can have no financial interest in making corrections to the systems. As special inspectors HERS raters can not be employed by subcontractors or parties, other than the builder, whose work they are evaluating. Building Departments Building departments consider approved HERS raters to be special inspectors. HERS raters must demonstrate competence; to the satisfaction of the building official, for the visual inspections and diagnostic testing. The building department, at its discretion, may require field verification testing and inspection to be conducted in conjunction with the building department's required inspections, and/or observe installer diagnostic testing and HERS rater verification in conjunction with the building department's required inspections to corroborate the results documented in installer certifications, and in the Certificate of Field Verification and Diagnostic Testing (CF -4R). • P.O. Box 1443 • Palm Springs, Ca 92263-1443 • E-mail: Cmadlin@aol.com • I V _ :_....... 1 �----- �} i I j � i - i t 1 1 i( � — f r✓ '; ,ice ,r" \\ i; • P.O. Box 1443 • Palm Springs, Ca 92263-1443 • E-mail: Cmadlin@aol.com • Madlin s en teipmes Catherine M. Madlin, Cetfified Energy Analyst v 760-322-5004 / 323-3644 (fax) .V ... ® v e Manufacturer's Specifications Rosi -tance Factor (RI of :te irci Eoard BuPdiriq Paper R-,.F_iue Gypsum Board 1/2" 0.45 FALCON FOAM'' @ Type IY75-F 5/8" 0.56 Plywood 1/4" 0.31 Polyurethane/Polyisocyanurate 3/8" 0.47 5.60 1/2" 0.62 Mineral Wool Per Inch/75'F 3/4" 0.94 Hardboard, Underlayment 1/4" 0.31 Cellulosic/Inch 1" 1.24 . BuPdiriq Paper Insulation Board - FALCON FOAM'' @ Type 1175"F 3.90 FALCON FOAM- @ Type V11Y75'F Permeable Felt, 151b. FALCON FOAM'' @ Type IY75-F 0.06 FALCON FOAM' @ Type DU75'F Plastic Film Extruded Polystyrene @ 75F Neg Polyurethane/Polyisocyanurate Aged @ 75-F 5.60 Insulation batts:blankets Concrete blocks, three oval cores Mineral Wool Per Inch/75'F 3.66 Insulation Loose Fill Cinder aggregate 4" thick 1.11 Cellulosic/Inch 3.1-3.7 12" thick 1.89 ' 2.1-2.3 8" thick 1.72 SurfaLE :lir Fiiras, ir:side (Stitt Sand and Gravel Aggregate 8" thick 1.11 (through a horizontal surface) Lightweight Aggregate 8" thick 2.00 Reflective 1.32 4" thick 1.50 (through a horizontal surface) Gypsum Mortar or Plaster 1/4" 0.05 Reflective 4.55 1/2" 0.10 (through a vertical surface) 1' 0.20 rdlaving Air Surfaces Gypsum Plaster (Perlite) Gypsum Plaster (Vermiculite) 1" 1" 0.64 0.59 15 MPH Wind (Winter) Brick, per inch - 7.5 MPH Wind (Summer) 0.20 Fake brick, per inch 0.11 Stucco, per inch 0.20 Roofing W.atsriafs Asbestos Cement Shingles 0.21 Asphalt Roll Roofing 0.15 Asphalt Shingles 0.44 ' Built Up Roofing 3/8" 0.33 Wood Shingles 0.94 Sid€rig Materials ' Asbestos Cement, 1/4" thick lapped 0.21 Asphalt 0.15 Wood Shingle, 16"x7.5" Exposure 0.87 Double with 12" Exposure 1.19 ' Wood Drop Siding, 1 "x8" 0.77 Wood Bevel Siding, .5'x8" {lapped) 0.81 Wood Bevel Siding, .3/4'x10" (lapped) 1.05 Wood Plywood, .318" (Lapped) 0.59 Structural Glass 0.10 Frrsuiation Wilater:ais R-tiZiue Insulation Board - FALCON FOAM'' @ Type 1175"F 3.90 FALCON FOAM- @ Type V11Y75'F 4. FALCON FOAM'' @ Type IY75-F 4.40 FALCON FOAM' @ Type DU75'F 4.40 Extruded Polystyrene @ 75F 5.00 Polyurethane/Polyisocyanurate Aged @ 75-F 5.60 Insulation batts:blankets 1.02 (Winter) Mineral Wool Per Inch/75'F 3.66 Insulation Loose Fill 3.59 (Winter) FALCON FOAM' 3.40 Cellulosic/Inch 3.1-3.7 Perlite, Expanded/Inch 2.2-2.9 Vermiculite, exfoliated/inch 2.1-2.3 :air S p2cc-s (-14-1 Heat Flow Up Non -reflective 0.75 (Summer) 0.87 (Winter) Reflective, one surface 2.22 (Summer) 2.21 (Winter) Heat Flow Down Non -reflective 0.85 (Summer) 1.02 (Winter) Reflective, one surface 3.29 (Summer) 3.59 (Winter) Heat Flow Horizontal Non -reflective 0.84 (Summer) 1.01 (Winter) Reflective, one surface 3.24 (Summer) 3.46 (Winter) SurfaLE :lir Fiiras, ir:side (Stitt Air) Heat Flow Up (through a horizontal surface) Non -reflective 0.61 Reflective 1.32 Heat Flow Down (through a horizontal surface) Non -reflective 0.92 Reflective 4.55 Heat Flow Horizontal (through a vertical surface) Non -reflective 0.68 rdlaving Air Surfaces Any Position or Direction 15 MPH Wind (Winter) 0.17 7.5 MPH Wind (Summer) 0.25 -�. @ r��`-, rte: ' lc FaanV 1 1 Andersen. Center of Glass Performance Data Dual -Pane Glass (Air filled) _ Casement/Awning, Tilt -Wash, Woodwright; Narroline° Transom Fixed (Picture Windows) Circle Top" Perma-Shield" Narroline° Gliding Patio Door Fleldframe° Arch Top, Springline'" High -Performance" Low -E Glass (Dual -pane, low -E, argon blend filled) Casement, Awning, Tilt -Wash, Woodwright; Transom_ Casement Picture, Awning Double -Hung Picture __ Gliding Windows 1400 Series) Circle Top, "i cal T 6 Circle, oval Perma-Shield° Patio Door, Narrofine° Gliding Patio Door - Frenchwood° Hinged, Outswing, Glidin; Flexitrame, Arch Windows_, Springlfne'" Roof Windows/Skylights (tempered) Laminated (all products) Inside Surface Visible 0.49 0.43 102 ! Fading I %HR ' Glass Ll ( SC' SC' SHGC' RHG` I TuV. Tdw ;U-Factor4center i Temp" 60% 56°F �- 0.50 I ' 104 17% 34% 0.28 83% 1 0.92 0.79 191 62% 64% 0.50 41% 45°F 82% ! 0.90 { 0.77 ' 187 ! 57% { 60% 0.49 1 41°% 46°F 83% j 0.92 0.79 191 ! 62°% 65% 0.49 { 41% i 45°F 82% ! 0.87 j 0.75 i 181 I 54% I 58% 0.49 42% 46°F 80% 0.82 0.71 I` 172 i 47% , 53% 0.48 1 42% 46°F 1 Inside { i 1 Surface Visible ! 1 Fading %HR I Glass Light' SC' SHGC' RHG` t Tuv° Tdwe ;U-Factor'I@centersTemp` f i 73% i 0.50 0.43 104 I 17% { 34% 0.28 60% { 55°F ( 1 73°% 0.49 0.43 102 ! 16% i 33% 0.28 { 60% i 56°F 73% 0.50 j 0.43 104 i 17% 34% 0.28 60% 56°F 73% 0.50 I 0.43 i 104 17% 34% 0.28 60% 56°F 54°F Picture Units- CA, NL, DHP 0%0.35 .i it to forced 0.30 { 74 15°% 23% 1 0.30 ' 72°% 0.49 ` 0.42 101 15°% 32% 0.27 I 60% 56°F 72°% _I 0.49 0.42 101 ? 15°% 32% 0.28 60% i 56°F 71% _ 0.47 L 57% 98 14% 31% 0.27 61% 56°F 73°% 0.49 { 0.43 { 102 j 16°% ; 33% 0.28 1 60% ! 56°F 71°%_ 0.49 0.42 I 1012% i 25% ; 0.28 60°% 5 °F High -Performance Sun'" Low -E Glass (Dual -pane, tinted Low -E, argon blend filled) ! ` 1 ( Visible { Lightt 1 SC2 SHGC' RHG` Fading TuO Tdw1 i i %HR 11.1-Facto"lecentere Inside i surface I Glass 1 Temp` Casement, Awning, Tift-Wash, The mullion was tested and the deflection was within the maximum allowable of L/175 at positive { ! I ! ` Woodwright, Transom 40% ; 0.36 {_0.31 r 76 16°% 24% 0.31 i 58% 54°F Picture Units- CA, NL, DHP 0%0.35 .i it to forced 0.30 { 74 15°% 23% 1 0.30 ' 57% 54°F Gliding Windows 40°% 0.36 ! 0.31 I 75 16°% 24% i 0.30 57% 54°F Circle Top, Sliptical Top, Circle, Oval 1 40% ; 0.36 0.31_i 75 16°% 24% 1 0.30 I 57% { 54°F _Perma-Shield° Patio Door _ L39% i 0.34 0.30 1 73 1 14% I 22°% 0.30 I 58°% { 5_4°F Frenchwood° Hinged, Gliding 39%! 0.35 I 0.30 { 73 14% 22°% 0.30 i 58°% i 54°F Flexiframe°Arch Windows, Springline' 38°1 , 0.33 1 0.29 j 71 13% j 21% '; 0.30 58% 55°F Roof WindowsJSlrylights (tempered) 39% i 0.34 T 0.30 73 14% 1 22% 1 0.30 58% 54°F Laminated (all products) 39°% ; 0.35 j 0.30 73 2% 16% ! 0.30 ! 58% I 55°F This data is accurate as of August 12, 2003. Due to ongoing product changes, updated test results, or new industry standards, this data may changeover time. Canadian Product Performance Ratings 'High -Performance' (HP Low -E) and 'High -Performance Sun' (HP Sun) are Andersen trademarks for "Low -E' glass. Based on NFRC testing/simulation conditions using Windows 4.1 and NFRC validated spectral data. 01F outside temperature, 70'F inside temper- ature and a 15 mph wind. 1 Visible Transmittance (Vo measures how much light comes through the glass. The higher the value, from 0 to I, the more daylight the glass lets in. Visible Transmittance is measured over the 380 to 760 nanometer portion of Ute solar spectrum. 2 Shading Coefficient defines the amount of heat gain through the glass compared to a single lite of clear 1/8" (3 MM) glass. 3 Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the glass. 4 Relative Heat Gain is calculated under a different set of assumptions than thermal performance. 5 Transmission Ultra -Violet Energy (TUY).The transmission of shon wave energy in the 300- 380 nanometer portion of the solar spectrum. The energy can cause fabric fading. 6 Transmission Damage Function (TOW). The transmission of short wave energy in the 300- 600 nanometer portion of the solar spectrum. The value includes both the UV and visible light energy that can cause fabric fading. This rating has also been referred to as the xrochmann Damage Function. This rating better predicts fading potential than UV transmission alone. The lower the Damage Function rating, the less transmission of short wave energy through the glass that can potentially cause fabric fading. Fabric type is also a key component of fading potential. 7 U -Factor is a measure of the heat loss through the total unit in BTU& deg.F sq. ft. 8 Percent relative humidity before condensation occurs at the center of glass, taken using center of glass temperature. 9 Inside glass surface temperatures are taken at the center of glass. Tested to: CAN/CSA A440 -M90 The mullion was tested and the deflection was within the maximum allowable of L/175 at positive and negative loads of 2600 Pa. ` 1 Windload I Resistance f I Windload Resistance Units Air I Water j Resistance it to forced Units 1Air I Water i Resistance to forced _Tested Tightness i Tightness ; and blow-out t entry Tested Tighbriess Tightness i and blow-out entry CW16 A;3 B-7{ C 4 Pass FX -12050 Fixed_ B-7 ; C-5_ 1 Not Applicable P6050 _ Fixed I B-7 ^ C-4 _ Not Applicable AF -608 Fixed B-7 { CV5 I Not_�pplicable AP421V_ A-3 J B-4 _ C-2 I Pass SP -802 Fixed B-7 _ C=5 _ Not Applicable A3535 A-3 I B_3 j{ _ I C-3 - _ i Pass FWH6080AP A-3 { B-2 _C_3 Pass _ TW3862 A-2 B-3 { _ C+2 _ ; Pass 9080SASR A-3 { B-2 _ C-3 _� Pass _ NL3862 _' A-3 B-3 _ _ C-3 - 1 Pass FW06080AP B-4 C_3 -I Not Applicable DHP5662 _Fixed _ B-3 1 C-3 NotApp)icable 3180 A-3 i B-4 I C_3 Not Applicable G65 A-3 1 B-3 ) C-3 1 Pass FWG8080 A-3 B-3 _ - _ I C-1 Pass CirfOv13048 Fixed B-7 I G5 I NotApplicabte 160611 A,3 B-2 C-1 { Pass E178 y Foxed - i B-7 .__ - C-5- i Not Applicable PSG8080 _ A-3 I B-2 7� _ I C-1 -- _� Pass 238 AS}(ili'��3B�a87[;SLiL�➢EIL��.53C.tialDlAt_�Ifirrii.l�l�iY3E11C�1r 9d i.aIE.Y�7L ilQYYa6Y.ma Y.��casr��s__------.--.-_ _.. Performance Data Andersen' NFRC Certified Total Unit Performance _ Andersen windows and patio doors meet or exceed the following standards: WDMA; I.S: 2, W.D.M.A -I.S. 4 (WDMA license No. 129), Hallmark certified. Independent testing laboratories have performed all required tests on selected saes Compliance with Orae standards is confirmed by ongoing testing in Andersen Laboratories. These products are covered by one or more of the following patents: 4,999,950; 5,595,409; 5,775,749; 6,055,786; 5,544,450; 5,566,507; 5,582,445; 5,097,629; 5,740,632; 5,199,234; D312,565; D397,604; and D417,831. Other patents pending. Casement 48"x48"size Without Grilles 0.62 0.34 400 Series Windows 0.33 HP HP Sun HP HP Sun Andersen' Product Type _ Low -E Low -E_ _ Low -E Low -E Casement _ U -Factor' 0.33 0.35 0.34 0.36 24" x 48" size SHGC' 0.337 0.24 0.30 0.22 VP VP 0.53 0.29 0.48 0.26 Awning U -Factor' 0.33 0.35 0.34 0.36 48" x 24" size SHGC' 0.32 0.24 0.30 i 0.22 VP VP 0.52 i 0.28 0.47 0.26 Casement/Awning U -Factor' 0.30! 0.32 _ 0.32_ 0.34 Picture Window SHGC' 0.36 0.26 0.33 0.24 48" x 48" size VP 0.59 0.32 0.53 0.29 Woodwright' U -Factor' 0.33 0.35 0.3_4 0.36 Double -Hung SHGC' _0.320.24 _ - 0.29 0.22 36" x 60" size VP 0.51 0.28 1 0.46 0.25 Woodwright" U -factor' _0.30 0.32 0.32_ 0.34 Picture Window I SHGC' 0.33 0.24 0.31 0.22 48" x 48" size VP 0.54 0.29_ 0.48 0.26 _ Woodwriight" _ _ U -Factor' 0.30 10.32 0.32 0.34 Transom SHGC' 0.35 0.25 0.32 0.23 48" x 48' size VP 0.57 0.31 0.51 0.28 Tilt -Wash U -factor' 0.34 0.36 0.35 I 0.35 Double -Hung SHGC' 0.3_2_ 0.24 0.29 0.22 36" x 60" size VP 0.51 0.28 0.45 0.25 Tilt -Wash U -Factor' _0.33 0.35 0.35 0.37 Double -Hung Picture ! SHGC' 0.35 0.25 0.32 0.24 48" x 48" sae I VP 0.56 0.30 0.50 0.27 Tilt -Wash U -Factor' 0.33 0.35 0.34 0.36 Double -Hung Transom SHGC' ( 0.35 0.25 _0.32 0.23 48" x 48" size VP 0.56 0.31 7 I 0.50 0.27 Gliding Window U -Factor' _0.36 0.38 _0.38 0.39 60" x 36" sae I SHGC' _0.30 I 0.23 j0.28 0.21 VP 0.46 0.25 j 0.41 0.22 Elliptical Window U -Factor' 0.30 0.32 1 0.32 0.34 48" x 48" size SHGC' 0.36 0.26 0.33 0.24 VP 0.59 0.32 1 0.53 0.29 Circle Top" U -Factor' 0.30 -0.36 0.32 _ 0.32 0.34 Casement SHGC' 0.26 0.33 0.24_ Tx 48" sae VP 0.59 0.32 0.53 0.29 _ Circle/Oval U -Factor' 0.30 0.32 J 0.32 0.34 48" x 48" size I SHGC' 0.36 0.26 1 0.33 0.24 VP 0.59 0.32 0.53 0.29 Arch Windows U -Factor' 0_.31 0.33 0.32 0,.34 48" x 48" size SHGC' 0.36 0.26 0.33_ 0.24 VP 0.59 0.32_ 0.53 + 0.32 0.2_9 0.34 _ Flex,, ame° ! U -Factor' 0.30 0.32 48" x 48" size I SHGC' 0.36 0.26 0.3_3 0.24 VP 0.59 0.32 i 0.53 0.29 _ Springline"Window ( U -Factor' 0.34_ 0.36 0.36 0.38 48' x 48" sae SHGC' 0.35 0.26 0.32 0.24 - - - - I - ._.-.- . VP - 0.55 0.30 0.50 0.27 Tem_pera_ d 07,- Skylight I U -Factor' 0.44 0.46 0.44 0.46 48" x 48" size SHGC' 0.42 0.31 j 0.4_2 0.31 _VP 0.67 0.37 0.65 0.36 Venting U -Factor' 0.42 0.44 0.42 0.44 Roof Window SHGC' 0.40 0.29 i 0.39 0.29 Casement 48"x48"size JVP 0.62 0.34 0.60 0.33 HP i Stationary U -Factor' +0.42_ 0.44 0.42_ 0.44 Low -E Roof Window I SHGC' _0.40 0.30 ` 0.39 0.29 Gliding Patio Door 48" x 48" size VP _ 0.64 - 0.35 i 0.60 0.33 Casement U -Factor' Without Grilles 400 Series Doors SHGC' HP HP Sun HP i HP Sun Andersen' Product_ _Ty_p_e _Low -E Low -E Low -E Low -E Frenchwood' U -Factor' 0.33 i 0.35 0.35 0.36 Gliding Patio Door SHGC' 0.29 0.21 0.26 0.20 72" x 82" size _ VP 0.44 0.24 0.39 1 0.21 Frenchwood' U -Factor' 0.33 ! 0.34 0.34 0.36 Hinged Patio Door I SHGC' 0.27 j 0.20 _; 0.25_ 0.19 38" x 82" size _ VP 0.41 0.22 0.36 0.20 Frenchwood' U -Factor' 0.34 0.36 0.36 0.37 Outswing Patio Door SHGC' 0.27 0.20 L 0.25 0.19 38" x 82' size I VP 0.41 0.22 0.36 0.20 _ Frenchwood' _ U -Factor' 0.35 0.36 0.35 0.36 Patio Door Sidelight SHGC' 0.15 0.19 0.15 16" x 82' sae_ VP _0.20 0.27 0.15 r 0.26 i 0.14 Frenchwoo& I U -Factor' 0.34 0.35 0.34 0.35 Patio Door Transom SHGC' 0.16 0.13 0_15 0.12 38_' x 14' size - - _ VP 0.20 0.11 0.19 0.10 Without Grilles 200 Series Windows & Doors Clear _ I Clear i Andersen° Product Tvne Dual -Pane Low -E Dual -pane Lnw-E Casement U -Factor' 0.48 -_ 0.49 - 24" x 48" sae SHGC' 0.57 - �_ 0.52 - VP 0.59 - 0.54 _ Aw Awning U -Factor' 0.48 - 0.49 - 48"Aw x 24' size SHGC' VP 0.56 - 0.52 0.58 0.53 - Tilt -Wash Double -Hung U -Factor' SHGC' 0.49 0.34 0.50 0.35 _ 0.56_ 0.33 0.51 0.30 36" x 60" sae VP 0.58 0.51 0.52 0.46 Narroline° j U -Factor' 0.50 ! 0.35 0.50 0.36 Double -Hung SHGC' _0.58 _0.33_ 0.52 0.31_ 36" x 60" sae VP 0.60 0.53 0.53 0.47 Narroline° Transom I U -Factor' 0.47 0_.31 0.48 0.33 48" x 48' sae I SHGC' _ 0.59 _ 0.34 0.54 0.31 VP 0.62 0.55 0.56 0.49 Gliding Window U -Factor' , 0.35 1 0.50 0.35 60" x 36' sae SHGC' _0.50 0.57 0.33 0.51 0.30 VP 0.58 0.52 0.52 0.46 Fixed, Transom, U -Factor' 0.47_ 0.31 0.48 0.33__ Circle Top" SHGC' 0_.60 0.34 0.54 0.32 48" x 48" size VP 0.62 0.55 0.56 0.49 Narroline° 1 U -factor' 0.49 0.32 0.50 0.35 Gliding Patio Door I SHGC' _ 0.60 0.3_5 0.54 0.32 72" x 82" size _ i VP 0.62 0.55 0.56 0.49 Perma-Shield" U -Factor' 0.47 0.31 0.48 __0_ 33 Gliding Patio Door SHGC' _ 0.60 0.34 0.54 _0.32 _ - 72" x 82" size VP _ 0.62 0.56 0.56 0.50 Grilles-Finelight or Full Divided light. "High -Performance" (HP Low -E) and "High -Performance Sun- (HP Sun) are Andersen trademarks to: 'LOW -E' pjass 1 U -Factor defines the amount of heat loss through the total unit in BTU/hr sq. It -.'F The lower the value, the less heat is lost through the entire product. 2 Solar Heal Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward The lower the value, the less heat is transmitted through the product. 3 Visible Transmittance (VT) measures how much light comes through a product (glass and frame). The higher the value, from 0 to 1, the more daylight the product lets in mer the products "Olaf unit area Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. This data Is accurate as of August 12, 2003. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. Andersen. 400 Series Air Infiltration, Testing and Light Transmittance I Available with Stormwatch' Protection - including design pressure upgrades. For a copy of the Andersen Coastal Product Guide, contact yourAndersen supplier. • Applicable only when DP upgrade kit is installed with factory prefinished while interior units (with prefinrshed interior trim stop option). •• Did not meet minimum she requirements for NAFS-02 testing. ^ STC and 01TC ratings given are for individual units based on independent tests and represent the entire unit. Higher STC and OR values may be available with other glazings. Contact Andersen for more information. This data is accurate as of August 12, 2003. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. Coil your Andersen representative for current performance information or upgrade options. Sound i AAMA/WDMA Certified Trans. ' Performance 101/ I.S. 2/NAFS-02 Ali Infiltration Class Andersen Product Rating Standard ct./h. (m/h./m°) (STC), OITC- 400 Series Casement Windowt DP 40 C -C 40 36 x 72 0.03 (.54) 25 22 400 Series Awning Windowt_ DP 35 AP -C 35 65 x 28 0.04 (.73) : 26 22 400 Series Casement and Awning Picture Windowst DP 60 F -C 60 72 x 60 <.01 (.18) ' 30 25 400 Series Woodwri0fir Double hung DP 30 ! H -LC 30 46 x 77 0.14 (2.52) 27 ; 23 f 400 5e i6sWooMghr Double-Hung'Pichure Window DP 65 ) F -C 65 67 x 77 <.01 (.18) ; 28 23 '400 SweswoodwnghC i Doubl"ungTiansorn•Window r DP 65 ( TR -LC 65 75 x 27 <.01 (.18) i 28 i 22 400 SedesTilt-Wash-Double-flung# i I ' (wimsndamansmp) _ _ _ DP 30 f H -R 30 46 x 72 0.10 (1.80) ; 27 1 23 400SeriesTilt-Wash rouble-Nungt 52 (1321ann) #ieightand ODder _ DP 50 i H -R 50 38 x 65 0.24 (4.39) ' 27 23 400 series- ilt Wash Double -'Hung i Picture Windowt __ - DP 50 F -R 50 67 x 77 <.01 (.18) : 26 - 400 Series Titt4NasrpoMe,4Hung Transom Windowt -_' DP 30 1_ _ _** 0.05 (.91) i 27 23 400 S. -es (tiidriig'V pdow;: DP 30 HS -C30 72 x 60 0.02 (.36) ! 25 21 r _ __ 4ff0 SenesRoofWmdow{Stationary] DP 40 0.01 (.18) ! 30 24 OOM&MinqTqv('u'errting) DP 25 *" 0.01 (.18) ; 3_4 28 yL` DP 65 _- _ SKG-C 65 56 x 56 0.02 (36) - 30 24 " 400 Selaes Cirole%p,, aii� -- . ' EtGptical ViidoWssY _r .., DP 65 "* <.01 (.18) 32 - L400.Sedes.Cudeand'0%61' .Windowt DP 65 ** <.Ol (.18) 25 - t. 40,66 iesArc6W'indof:' DP 65 i ** <.Ol (.18) ! - - r- - , - AO0SeiiesFlex1ffarhd*Vindowt DP 65 " <.01 (18) 30 - F 400 SeriesSpringfirf Vindowt DP 65 1 F -HC 65 96 x 72 <.01 (.18) : - - 400 Series Fsenchwood' Glidin -Patio Doorst 16080 DP 35 SGD-LC 35 189 x 96 0.05 (.91) 31 26 160611 SRD DP 25 SGD-LC 25 189 x 82 0.05 (.91) : 31 26 REINFORCED_ _ _ _ DP 40 ( SGD-LC 40 189 x 8_2 0.05 (.91) 31 26 16068 _ _ DP 30 SG_D-LC 30 189 x 80 0.06 (1.10) ; 31 26 8080, 6080_ DP 50 SGD-LC 50 96 x 96 0.03 (.54) ' 31 26 60611, 8068, 80611, 6080 DP 60 SGD-LC 60 96 x 82 0.08 (1.46) ! 31 26 400'Series fienchw6o(r. Kngeii3?atio 6080 AP/PA DP 40 HGD-R 40 71 x 96 0.02 (.36) 32 26 9080 SASR_ _ _ _ _ DP 40 HGD-R 40 107 x 96 0.01 (.18) I 32 26 6080 SA DP 40 HGD-R 40 71 x_96 ! 0.01 (.18) 32 26 3180S DP 60 j HGD-R 60 36 x 96 0.02 (.36) ; 32 ; 26 90611 SASR DP 50 ' HGD-R 50 107 x 82 0.01 (18) ' 32 j 26 60611 AP/PA DP 40 I HGD-R 40 71 x 82 0.02 (.36) 32 ; 26 60611 SA DP 50 HGD-R 50 71 x 82 0.01 (.18) ' 32 ! 26 31611 A DP 60 i HGD-R 60 36 x 82 0.01 (.18) j 32 26 400 Series Frenchwood' Ou tswing Patio Doors 3180 DP 50 I HGD-R 50 36 x 95 0.02 (.18) ; 31 26 6080 AP/PA DP 40 j HGD-R 40 71 x 95 0.02 (.18) ! 31 26 400 Series Frenchwood' Sidelights DP 77 SL_LC 77 19 x 96 <.01 (.18) j - - i 400 Series frenchwood'Transoms DP 77 ! TR -LC 77 96 x 82 <.01 (.18) I Available with Stormwatch' Protection - including design pressure upgrades. For a copy of the Andersen Coastal Product Guide, contact yourAndersen supplier. • Applicable only when DP upgrade kit is installed with factory prefinished while interior units (with prefinrshed interior trim stop option). •• Did not meet minimum she requirements for NAFS-02 testing. ^ STC and 01TC ratings given are for individual units based on independent tests and represent the entire unit. Higher STC and OR values may be available with other glazings. Contact Andersen for more information. This data is accurate as of August 12, 2003. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. Coil your Andersen representative for current performance information or upgrade options.