Loading...
BRES2018-0378 Title 24BUILDING ENERGY ANALYSIS REPORT '�3R65SUIg-o3`7S PROJECT: Fire Damage 44185 Carmen PL La Quinta , Ca 92253 Project Designer: Powell & Assosicates Inc. 9980 Indiana Ave Ste 3 Riverside, Ca 92503 951-352-3588 Report Prepared by: Robert Gonzales DESIGN 4 BUILDING 7755 Center Ave. Suite #1100 Huntington Beach, Ca 92647 562-981-4890 CITY OF LA QUANTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE 1 DATE + r D SY DESIGN ;40BUILDING Job Number: 18-520 Date: 11/11/2018 RECEIVED DEC 2 U 2018 CITY 0E LA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. zND CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD �—Project Name: 44185 Carmen PL Calculation Date/Time: 10:27, Sun, Nov 11, 2018 Calculation Description: Title 24 Analysis Input File Name: 18-520.ribd16x COMPLIANCE RESULTS CF1 R-PRF-01 Page 1 of 8 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HER provider. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED Registration Number: 418-P010089220A-000-000-0000000-0000 Registration Date/Time: 11/11/2018 10:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-11-11 10:27:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 44185 Carmen PL Calculation Date/Time: 10:27, Sun, Nov 11, 2018 CF1 R-PRF-01 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: 18-520.ribd16x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • --None-- Cooling System Verifications: • Minimum Airflow • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 44185 Carmen PL 1935 1 4 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftZ) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Exist. 2nd Floor Conditioned HVAC System1 818 8 DHW Sys 1 n/a Exist. 1st Floor Conditioned HVAC System1 1117 8 DHW Sys 1 n/a Registration Number: 418-P010089220A-000-000-0000000-0000 Registration Datefrime: 11/11/2018 10:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-11-11 10:27:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 44185 Carmen PL Calculation Date/Time: 10:27, Sun, Nov 11, 2018 Calculation Description: Title 24 Analysis Input File Name: 18-520.ribd16x CFI R-PRF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ftZ) Tilt (deg) Wall Exception Status Verified Existing Condition Front Wall Exist. 2nd Floor R-13 Wall 90 Front 208 0 90 n/a Altered n/a Left Wall Exist. 2nd Floor R-13 Wall 180 Left 304 40 90 n/a Altered n/a Rear Wall Exist. 2nd Floor R-13 Wall 270 Back 208 16 90 n/a Altered n/a Right Wall Exist. 2nd Floor R-13 Wall 0 Right 304 44 90 n/a Altered n/a Roof Exist. 2nd Floor (N) R-30 Roof Attic 818 n/a Altered n/a Interior Surface Exist. 2nd Floor»Exist. 1st Floor R-0 Floor No Crawlspace 818 n/a I Existing No Front Wall 2 Exist. 1st Floor R-13 Wall 90 Front 312 77 90 n/a Altered n/a Left Wall 2 Exist. 1st Floor R-13 Wall 180 Left 288 20 90 n/a Existing No Rear Wall 2 Exist. 1st Floor R-13 Wall 270 Back 312 72 90 n/a Altered n/a Right Wall 2 Exist. 1st Floor R-13 Wall 0 Right 288 32 90 n/a Altered n/a Roof 2 Exist. 1st Floor Default Roof 1978 to Pres 1117 n/a Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Exist. 2nd Floor Attic RoofExist. 2nd Floor Ventilated 4 0.1 0.85 No No Existing No Attic Exist. 1st Floor Attic RoofExist. 1st Floor Ventilated 4 0.1 0.85 No No Existing No Registration Number: 418-P010089220A-000-000-0000000-0000 Registration Date/Time: 11/11/2018 10:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-11-11 10:27:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 44185 Carmen PL Calculation Date/Time: 10:27, Sun, Nov 11, 2018 CF1 R-PRF-01 Page 4 of 8 Calculation Description: Title 24 Analysis Input File Name: 18-520.ribd16x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Status Verified Existing Condition Glass Door Left Wall (Left-180) — 1 40.0 0.55 0.67 Insect Screen (default) Existing No Window Rear Wall (Back-270) - 1 16.0 0.55 0.67 Insect Screen (default) Existing No Window 2 Right Wall (Right-0) — -- 1 44.0 0.55 0.67 Insect Screen (default) Existing No Window 3 Front Wall 2 (Front-90) — — 1 35.0 0.55 0.67 Insect Screen (default) Existing No Window 4 Left Wall 2 (Left-180) — 1 20.0 0.55 1 0.67 Insect Screen (default) Existing No Glass Door 2 Rear Wall 2 (Back-270) 1 40.0 0.55 0.67 Insect Screen (default) Existing No Window 5 Rear Wall 2 (Back-270) — — 1 32.0 0.55 0.67 Insect Screen (default) Existing No Window 6 Right Wall 2 (Right-0) — — 1 32.0 0.55 0.67 Insect Screen (default) Existing No OPAQUE DOORS 01 02 1 03 04 05 06 Name Side of Building Area (ft2) U-factor Status Verified Existing Condition Front Door Front Wall 2 42.0 0.50 New No Registration Number: 418-P010089220A-000-000-0000000-0000 Registration Date/Time: 11/11/2018 10:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-11-11 10:27:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 44185 Carmen PL Calculation Date/Time: 10:27, Sun, Nov 11, 2018 Calculation Description: Title 24 Analysis Input File Name: 18-520.ribdl6x CF1 R-PRF-01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers - Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic RoofExist. 2nd Floor Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.101 • Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-14.3/2x6 (N) R-30 Roof Attic attic) Wood Framed Ceiling 2x6 @ 16 in. O.C. R 30 0.032 • Over Ceiling Joists: R-15.7 insul • Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking • Cavity / Frame: no insul. / 2x 12 R-0 Floor No Crawlspace Interior Floors Wood Framed Floor 2x12 @ 16 in. O.C. none 0.196 • Ceiling Below Finish: Gypsum Board • Cavity/ Frame: no insul / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic RoofExist. 1st Floor Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below • Cavity/Frame: R-9.1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Ceiling Joists: R-9.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value Carpeted Fraction Heated Status Verified Existing Condition Slab Exist. 1st Floor 1117 1 150 1 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a Registration Number: 418-P010089220A-000-000-0000000-0000 Registration Date/Time: 11/11/2018 10:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-11-11 10:27:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 44185 Carmen PL Calculation Date/Time: 10:27, Sun, Nov 11, 2018 Calculation Description: Title 24 Analysis Input File Name: 18-520.ribd16x WATER HEATING SYSTEMS 03 04 05 01 02 Name System Type DHW Sys 1 DHW WATER HEATERS 01 02 03 04 Heater Element Number Name Type Tank Type I of Units DHW Heater 1 Gas Small Storage 1 Number of Distribution Type Water Heater Heaters Standard I DHW Heater 1 1 CF1 R-PRF-01 Page 6 of 8 06 07 08 Solar Fraction Verified Existing (%) Status Condition 0 Altered No 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Tank Uniform Energy Pilot / Insulation Loss / First Hour Tank Location Volume Factor / Energy Thermal R-value Recovery Rating / NEEA Heat Pump or Ambient (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Brand I Model Condition 50 0.65 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 08 01 02 03 04 05 06 07 Distribution Verified Existing SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Name Status Condition Other Heating and Cooling HeatingComponent 1 p Cooling Component 1 Air Distribution HVAC Fan 1 System 1 Altered No HVAC Systeml System HVAC - HEATING UNIT TYPES 02 03 04 01 System Type Number of Units Efficiency Name 1 80 AFUE Heating Component 1 CntrlFurnace HVAC - COOLING UNIT TYPES 08 01 02 03 04 05 06 07 Efficiency System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Name Cooling Component Cooling Component 1 SplitAirCond 1 11.7 14T Not Zonal Single Speed 1-hers-cool Registration Number: 418-P010089220A-000-000-0000000-0000 Registration Date/Time: 11/11/2018 10:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-11-11 10:27:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 44185 Carmen PL Calculation Date/Time: 10:27, Sun, Nov 11, 2018 Calculation Description: Title 24 Analysis Input File Name: 18-520.ribd16x HVAC COOLING - HERS VERIFICATION 01 02 Name Verified Airflow Cooling Component 1-hers-cool Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 Name Type Duct Leakage Air Distribution Ducts located in attic System 1 (Ventilated and Sealed and tested Unventilated) HVAC DISTRIBUTION - HERS VERIFICATION 01 1 02 Duct Leakage Name Verification Air Distribution System 1-hers-dist Required HVAC - FAN SYSTEMS & HERS VERIFICATION 01 Name HVAC Fan 1 IAQ (Indoor Air Quality) FANS 01 02 Dwelling Unit IAQ CFM SFam IAQVentRpt 0 03 Airflow Target 350 04 Verified EER Not Required 05 Verified SEER Not Required CF1 R-PRF-01 Page 7 of 8 06 Verified Refrigerant Charge Required 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS R-value Location Location Bypass Duct Status Condition Verification 6.0 Attic Attic None Altered No Air Distribution System 1-hers-dist 03 04 05 06 07 08 Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low -leakage Target (%) Location Design 9 Ducts Ducts Air Handler 5.0 Not Required Not Required Not Required Not Required n/a 02 03 04 Type Fan Power (Watts/CFM) EHER Verification Single Speed PSC Furnace Fan 0.58 Required 03 04 F 05 06 IAQ Recovery IAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification 0.25 Default 0 Not Required Registration Number: 418-P010089220A-000-000-0000000-0000 Registration Date/Time: 11/11/2018 10:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2016-11-11 10:27:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 44185 Carmen PL Calculation Date/Time: 10:27, Sun, Nov 11, 2018 Calculation Description: Title 24 Analysis DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Robert Gonzales Company: Design 4 Building Address: 7755 Center Ave. Suite 1100 City/State/Zip: Huntington Beach , CA 92648 RESPONSIBLE PERSON'S DECLARATION STATEMENT Input File Name: 18-520.ribdl6x Documentation Author Signature: RoveYtGonVaies- Signature Date. 11/11/2018 CEA/HERS Certification Identification (If applicable): Phone: 562-981-4890 CF1 R-PRF-01 Page 8 of 8 I certify the following under penalty of perjury, under the laws of the State of California. 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents. worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name Robert Gonzales Company: Design 4 Building Address: 7755 Center Ave. Suite 1100 City/State/Zip: Huntington Beach , CA 92648 Responsible Designer Signature Robei^tGow5alew Date Signed: 11/11/2019 License: Phone: 562-981-4890 Registration Number: 418-P010089220A-000-000-0000000-0000 Registration Date/Time: 11/11/2018 10:32 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-11-11 10:27:56 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type m Single Family ❑ Addition Alone Date Fire Damage ❑ Multi Family m Existing+ Addition/Alteration 111111201 Project Address California Energy Climate Zone Total Cond. Floor Area Addition j # of Units 44185 Carmen PL La Quinta CA Climate Zone 15 1, 935 0 1 INSULATION Area Construction Type Cavity ft Special Features Status Wall Wood Framed R 13 208 Altered Wall Wood Framed R 13 264 Altered Wall Wood Framed R 13 192 Altered Wall Wood Framed R 13 260 Altered Roof Wood Framed Attic R 30 818 Altered Demising Wood Framed w/o Crawl Space - no insulation 818 Existing Wall Wood Framed R 13 235 Altered Door Opaque Door - no insulation 42 New FENESTRATION Total Area: 259 Glazing Percentage: 13.4 % New/AlteredAvera a U-Factor: 0.00 Orientation Area(ff2) U-Fac SHGC Overhang Sidefins Exterior Shades Status Left (S) 60.0 0.550 0.67 none none Bug Screen Existing Rear (W) 88.0 0.550 0.67 none none Bug Screen Existing Right (N) 76.0 0.550 0.67 none none Bug Screen Existing Front (E) 35.0 0.550 0.67 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating 1 Central Furnace HVAC DISTRIBUTION Location Heath HVAC System Ducted WATER HEATING Qty. Type 1 Small Storage Gas Min. Eff Cooling Min. Eff Thermostat Status 80% AFUE Split Air Conditioner 14.0 SEER Setback Altered Cooling Duct Location n„,ro.4 n*#r.. Gallons Min. Eff Distribution 50 0.65 Standard Duct R-Value 6.0 Status Altered Status Altered 7.2 by En&rqySo# User Number. 20180 ID: 18-520 Pape 10 of 12 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type m Single Family ❑ Addition Alone Date Fire Damage ❑ Multi Family m Existing+ Addition/Alteration �1111112018 Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units 44185 Carmen PL La Quinta CA Climate Zone 15 1,935 0 I 1 INSULATION Area Construction Type Cavity (ft) Special Features Status Wall Wood Framed R 13 268 Existing Wall Wood Framed R 13 240 Altered Wall Wood Framed R 13 256 Altered Roof Wood Framed Attic R 19 1,117 Existing Slab Unheated Slab -on -Grade - no insulation 1,117 Perim = 150' Existing FENESTRATION I Total Area: 259 Glazing Percentage: 13.4 New/Altered Average U-Factor: 0.00 Orientation Area(ff) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qtv. Heating HVAC DISTRIBUTION Location Heati WATER HEATING Min. Eff Coolin Cooli Min. Eff Duct Location Gallons Min. Eff Distribution Thermostat Status Duct R-Value Status Status 7.2 by EnaoySoft User Number. 20180 ID: 18-520 Pape 1177 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Fire Damage 11/11/2018 System Name Floor Area HVAC System 1,935 Cw1!!IK10C13IAIl- t UC!`LFQ QVQTGnn 1 nnn Number of Systems 1 COIL CFM Total Room Loads 1,629 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 33,019 638 700 27,079 Total Output (Btuh) 80,000 0 Output Btuh/s ft) 41.3 1,827 1,202 Cooling System 0 0 Output per System 60,000 0 0 0 0 Total Output Btuh 60,000 0 638 0 Total Output (Tons) 5.0 1,827 1,202 Total Output (Btuh/sqft) 31.0 Total Output s ft/Ton 387.0 1 36,674 29,482 Air System CFM per System 1,800 HVAC EQUIPMENT SELECTION Airflow cfm 1,800 Furnace - A/C 31,803 18,856 80,000 Airflow cfm/s ft 0.93 Airflow (cfm/Ton) 360.0 Outside Air %Ia 0•0 % Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 31,803 18,856 80,000 Outside Air cfm/s ft 0.00 Note: values above givan at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF 67 OF 105 OF Outside Air 0 cfm Supply Fan Heating Coil 1,800 cfm 67 OF 104 OF ROOM 7 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/73OF 76/62OF 76/62OF 55/54OF Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,800 cfm 46.4 % ROOM = I 76/62OF 75161 OF ` I