0007-108 (SFD) Title 24Carole Christensen, Certified Energy Analyst Title -24 Energy Calculations August 9, 2000 ENERGY CALCULATIONS FOR: Sammy Labastida 51-505 Ave. Ramirez La Quinta, CA 92253 PROJECT: Labastida Residence Carranza La Quinta, CA 92536 Standard Proposed Compliance 63.59 61.03 +2.56 CTZ-15,12.4% fenestration Dual Aluminum fenestration, Default, Std. Drape Walls R-13; Roof R-30; Duct R-4.2 FAU 78%, SEER 12.0 One 50 gal or less gas water heater to meet minimum CEC standards Table of Contents CF -1R MF -IR C -2R 3-R HVAC CITY OF LA QUINTA BUILDING & SAFE -TY DEPT. FOR CONSTRUCTION DATE_ BY ►ce $51 47-596 Lake Canyon Drive, Aguanga, CA 92536 Off 1-800-735-8152 Member CABEC - California Association of Building Energy Consultants CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Labastida Residence Date..08/09/00 14:55:07 P t Add C ******* rojec ress........ arranIf. a La Quinta, CA 92253 *v5.10* Documentation Author... Carole Christensen ******* Building Permit Carole Christensen 47-596 Lake Canyon Drive Plan _CTFe_cT7 Date Aguanga, CA 92536 800-735-8152 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc. MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen Run - GENERAL INFORMATION Conditioned Floor Area..... 1392 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 12.4 % of floor area Average Glazing U -value.... 0.86 Btu/hr-sf-F Average Glazing SHGC....... 0.7 Average Ceiling Height..... 9.5 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R -value R -value R -value U -value Location/Comments Wall Wood R-13 R-0 R-13 0.088 Wall Wood R-13 R-0 R-13 0.086 To garage Roof Wood R-11 R-19 R-30 0.031 attic Door n/a R-0 R-n/a R-0 0.330 SlabEdge n/a R-0 R-n/a F2=0.720 to outside Slab9dge n/a R-0 R-n/a F2=0.500 to garage FENESTRATION ' Over - Area U- Interior Exterior hang/ Orientation (sf) Value SHGC Shading Shading Fins Window Front (W) 5.0 0.720 0.730 Standard Standard None Window Front (W) 3.0 0.720 0.730 Standard Standard None Window Front (W) 20.0 0.870 0.700 Standard Standard None Window Right (SW) 10.0 0.870 0.700 Standard Standard None window Front (NW) 10.0 0.870 0.700 Standard Standard None Window Left (N) 24.0 0.870 0.700 Standard Standard None Window Left (N) 16.0 0.870 0.700 Standard Standard None Window Back (E) 16.0 0.870 0.700 Standard- Standard None Door Back (E) 40.0 0.850 0.700 Standard Standard None Window Right (S) 16.0 0.870 0.700 Standard Standard None Window Right (S) 4.0 0.870 0.700 Standard Standard None Window Right (S) 9.0 0.870 0.700 Standard Standard None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Labastida Residence Date..08/09/00 14:55:07 MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen Run - Equipment Type Furnace ACSplit SLAB SURFACES Area Slab Type (sf) Standard Slab 1392 HVAC SYSTEMS Minimum Duct Duct Tested Duct ACCA Thermostat Efficiency Location R -value Leakage Manual D Type 0.780 AFUE Attic R-4.2 No No Setback 12.00 SEER Attic R-4.2 No No Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value Water Heater to meet minimum CEC Standards ' r REMARKS ' CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Labastida Residence Date..08/09/00 14:55:07 MICROPAS5 x5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen Run - COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... Sammy Labastida Company. Owner/Builder Address. 51-505 Ave. Ramirez La Quinta, CA 92253 Phone... (760) 771-4339 License. Signed.. ate ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed. date DOCUMENTATION AUTHOR Name.... Carole Christensen Company. Carole Christensen Address. 47-596 Lake Canyon Drive Aguanga, CA 92536 Phone... 800-735-8152 Signed.. ate Cott�e Seetel Aftefrot Carole Christensen, CEPE r r R 98-99.239 LC r CAB California Association of Building Energy Consultants MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page I of 2) MF -1R Note: 1,owrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used ms marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures: ' §150(a): Minimum R-19 ceiling insulation. t� § 150(b): Loose fill insulation manufacturer's labeled R -Value. N f • §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-valuc in metal frame walls / (does not apply to exterior mass walls). (/ §150(d): Minimum R-13 raised floor insulation in framed floors. N § 150(I) : Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. / ✓ §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls I. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field-fabricated)have label with certified U -value, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors-aad windows weatherstripped; all joints and penetrations caulked and sealed. §15(,,`. Vapor barriers mandatory in Climate Zones 14 and 16 only. N p- § 150(f): Special infiltration barrier installed to comply with § 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. I. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gats pilot lights allowed. Space Conditioning, Water Heating and Plumbing System Measures: § 110-§ 113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Pipe and tank insulation I . Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All huried or exposed piping insulated in recirculating sections of hot water systems. 5. L erg system piping below 55° F insulated. 6. Piping insulated between heating source and indirect hot water tank. July 1, 1999 MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page 2 of 2) MF -1R Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) • § 150(m): Ducts and Fans I. All ducts and plenums constructed, installed, insulated, fastened, and scaled to comply with the ICBO 1997 UMC sections 601 and 603; ducts insulated to a minimum installed R-4.2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant or other duct closure system that meets the applicable requiremetns of UL181, UL181A, or UL181B and other applicable specified tests for longevity given in §150(m).. 2. Exhaust fan systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, / / manually operated dampers. ►►►/// § 114: Pool and Spa Heating Systems and Equipment. I. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 6L/ § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no / continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) I/ Lighting Measures: §150(k)I.: Luminaires for general lighting in kitchens shall have lamps with an efficacy of40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a / switch on a readily accessible lighting control panel at an entrance to the kitchen. 1/ t 50(k)2.. Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in § 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. July 1, 1999 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... Labastida Residence Date..08/09/00 14:55:07 ******* Project Address........ Carranza La Quinta, CA 92253 *v5.10* Documentation Author... Carole Christensen ******* Building Permit -79 Carole Christensen 47-596 Lake Canyon Drive Plan Check Date Aguanga, CA 92536 800-735-8152 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc. MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run- MICROPAS5 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 3.17 3.10 0.07 Space Cooling.......... 43.81 41.32 2.49 Water Heating.......... 16.61 16.61 0.00 Total 63.59 61.03 2.56 *** Building complies with Computer Performance *** Zone Type HOUSE Residence GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -value.... Average Glazing SHGC....... Average Ceiling Height..... 1392 sf Single Family Detached New Front Facing 270 deg (W) 1 1 ReducedYear Slab On Grade 1 13224 cf 1392 sf 12.4 % of floor area 0.86 Btu/hr-sf-F 0.7 9.5 ft BUILDING ZONE INFORMATION Floor # of Area Volume Dwell Cond- (sf) (cf) Units itioned 11 Vent Vent Air Thermostat Height Area Leakage Type (ft) (sf) Credit 1392 13224 1.00 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title'.......... Labastida Residence Date..08/09/00 14:55:07 MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run - OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 66 0.088 13 270 90 Yes W.13.2X4.16 2 Wall 18 0.088 13 225 90 Yes W.13.2X4.16 3 Wall 18 0.088 13 315 90 Yes W.13.2X4.16 4 Wall 268 0.088 13 0 90 Yes W.13.2X4.16 5 Wall 324 0.088 13 90 90 Yes W.13.2X4.16 6 Wall 178 0.088 13 180 90 Yes W.13.2X4.16 7 Wall 268 0.086 13 270 90 No GWALL.R13 To garage 8 Roof 1392 0.031 30 n/a 0 Yes R.30.2X4.24 attic 9 Door 20 0.330 0 270 90 Yes None 10 Door 20 0.330 0 270 90 No None Right (S) 4.0 0.870 0.700 PERIMETER LOSSES 90 Surface HOUSE 11 SlabEdge 12 SlabEdge Orientation HOUSE 1 Window 2 Window 3 Window 4 Window 5 Window 6 Window 7 Window 8 Window 9 Door 10 Window 11 Window 12 Window Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments 133 0.720 R-0 No to outside 36 0.500 R-0 No to garage FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC Front (W) 5.0 0.720 0.730 270 90 Standard/0.76 Standard/0.68 Front (W) 3.0 0.720 0.730 270 90 Standard/0.76 Standard/0.68 Front (W) 20.0 0.870 0.700 270 90 Standard/0.76 Standard/0.68 Right (SW) 10.0 0.870 0.700 225 90 Standard/0.76 Standard/0.68 Front (NW) 10.0 0.870 0.700 315 90 Standard/0.76 Standard/0.68 Left (N) 24.0 0.870 0.700 0 90 Standard/0.76 Standard/0.68 Left (N) 16.0 0..870 0.700 0 90 Standard/0.76 Standard/0.68 Back (E) 16.0 0.870 0.700 90 90 Standard/0.76 Standard/0.68 Back (E) 40.0 0.850 0.700 90 90 Standard/0.76 Standard/0.68 Right (S) 16.0 0.870 0.700 180 90 Standard/0.76 Standard/0.68 Right (S) 4.0 0.870 0.700 180 90 Standard/0.76 Standard/0.68 Right (S) 9.0 0.870 0.700 180 90 Standard/0.76 Standard/0.68 SLAB SURFACES Area Slab Type (sf) HOUSE Standard Slab 1392 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Labastida Residence Date..08/09/00 14:55:07 MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run - HVAC SYSTEMS Water Heater to meet minimum CEC Standards REMARKS Minimum Duct Duct Tested Duct ACCA Duct System Type Efficiency Location R -value Leakage Manual D Eff HOUSE ' Furnace 0.780 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 • WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value Water Heater to meet minimum CEC Standards REMARKS CONSTRUCTION ASSEMBLY Page 1 3R Project Title.......... Labastida Residence Date..08/09/00 14:55:07 MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run - Parallel Path Method Reference Name . W.13.2X4.16 Description .... Wall R-13 2x4 16oc Type ........... Wall R -Value ........ 13 Hr-sf-F/Btu Framing Material ..... FIR.2X4 Type ......... Wood Description .. 2x4 fir Spacing ...... 16 inches on center Framing Frac.. 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Name Description O. FILM.EX Exterior air film: winter value 1. STUCCO.0.88 0.875 in stucco 2. BLDG.PAPER Building paper (felt) 3c. BATT.R13 R-13 batt insul (cavity = 3.5 in) 3f. FIR.2X4 2x4 fir 4. GYP.0.50 0.50 in gypsum or plaster board I. FILM.IN.WLL Inside air film: heat sideways Total Unadjusted R -Values I.FRAMING ADJUSTMENT CALCULATION Cavity Framing U -Value: (1 / 14.53 x 0.85) + (1 / 5.00 x 0.15) _ Cavity R -Value U.1/ 0.17 0.06 13.00 0.45 0.68 Frame R -Value 0.17 0.17 0.06 3.46 0.45 0.68 14.53 5.00 Total 0.088 Btu/hr-sf-F Total R -Value: 1 / 0.088 = 11.30 hr-sf-F/Btu CONSTRUCTION ASSEMBLY Page 2 3R Project Title........:. Labastida Residence Date..08/09/00 14:55:07 MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run - Parallel Path Method Reference Name . GWALL.R13 Description .... Wall R-13 2x4 16oc Type ........... Wall R -Value ........ 13 Hr-sf-F/Btu Framing Material ..... FIR.2X4 Type ......... Wood Description .. 2x4 fir Spacing ...... 16 inches on center Framing Frac.. 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS I -FRAMING ADJUSTMENT CALCULATION Cavity I U -Value: (1 j 14.75 x 0.85) + (1 / Total R -Value: Framing 5.21 x 0.15) Total 0.086 Btu/hr-sf-F 1 / 0.086 = 11.58 hr-sf-F/Btu Material Cavity Frame Name Description R -Value R -Value O. FILM.EX Exterior air film: winter value 0.17 0.17 1. GYP.0.50 0.50 in gypsum -or plaster board 0.45 0.45 3c. BATT.R13 R-13 batt insul (cavity = 3.5 in) 13.00 -- 3f. FIR.2X4 2x4 fir -- 3.46 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 14.75 5.21 I -FRAMING ADJUSTMENT CALCULATION Cavity I U -Value: (1 j 14.75 x 0.85) + (1 / Total R -Value: Framing 5.21 x 0.15) Total 0.086 Btu/hr-sf-F 1 / 0.086 = 11.58 hr-sf-F/Btu CONSTRUCTION ASSEMBLY Page 3 3R Project Title.......... Labastida Residence Date..08/09/00 14:55:07 MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run - Parallel Path Method Reference Name . R.30.2X4.24 Description .... Roof R-30 2x4 24oc Type Roof R -Value ........ 30 Hr-sf-F/Btu Framing Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Name Description 0. FILM. EX 1. SHNGL.ASPHLT 2. BLDG.PAPER 3. PLY -0.50 4. AIR.RF.3.50 5. BATT.RI9.0 6c. BATT.RII.0 6f. FIR.2X4 7. GYP.0.50 I. FILM.IN.RF Material ..... FIR.2X4 Type ......... Wood Description .. 2x4 fir Spacing ...... 24 inches on center Framing Frac.. 0.07 Exterior air film: winter value Asphalt shingle roofing Building paper (felt) 0.50 in plywood 3.5 in & greater air space: heat flow up R-19 batt insul (cavity > 5.5 in) R-11 batt insul (cavity > 3.5 in) 2x4 fir , 0.50 in gypsum or plaster board Inside air film: heat flow straight up I'FRAMING ADJUSTMENT CALCULATION Cavity Total Unadjusted R -Values Framing Cavity R -Value 0.17 0.44 0.06 0.62 0.80 19.00 11.00 0.45 0.61 33.15 Total Frame R -Value U -Value: (1 / 33.15 x 0.93) + (1 / 25.62 x 0.07) = 0.031 Btu/hr-sf-F Total R -Value: 1 / 0.031 = 32.48 hr-sf-F/Btu 0.17 0.44 0.06 0.62 0.80 19.00 3.46 0.45 0.61 M671K..10 HVAC SIZING Page 1 HVAC Project Title.......... Labastida Residence Date..08/09/00 14:55:07 P rod e t Addr C ******* c ess........ arranza La Quanta, CA 92253 *v5.10* Documentation Author... Carole Christensen ******* Carole Christensen 47-596 Lake Canyon Drive Aguanga, CA 92536 800-735-8152 Climate Zone 15 Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc. MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen Run - GENERAL INFORMATION Floor Area ................. 1392 sf Volume ..................... 13224 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ PALM DESERT Latitude ................... 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range ............... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Bui i.ng Permit Plan Check Date Field -Check/ Date Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc. MICROPAS5 v5.10 File-LABASTDA Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen Run - GENERAL INFORMATION Floor Area ................. 1392 sf Volume ..................... 13224 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ PALM DESERT Latitude ................... 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range ............... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 10265 5716 Glazing Conduction ................ 5643 5049 Glazing Solar .................... n/a 7333 • Infiltration ..................... 6983 4621 Internal Gain .................... n/a 2550 • Ducts ............................ 2289 2527 Sensible Load .................... 25180 27797 Latent Load ...................... n/a 5559 Minimum Total Load 25180 33356 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment.