04212 (SFD) Title 24-T I -r L_ E--: �-fla- lr%.l E—_ F--,: If—s, V �����LJ 9-- ir--h -T- I C3 N1 F_ -c E -E 4=� 1. !!f � JOHN H. HACKER, CIVIL ENGINEER, PALM SPRINGS 327-4565 LATITUDE 33.0 WINTER TEMP, 31 DEG SUMMER TEMP. 110 DEG NAME ------- PACIFIC HABITAT ADDRESS ---- PLAN NO. 1369 CITY ------- LA QUINTA / CALIF. REF.CAL.ENERGY CONSERVATION DESIGN MANUAL, FORM 2, HEATING LOSSES MANUAL J FOR COOLING LOSSES AREA BLDG 1369 SQ. FT. PERIMETER 152.1111 SQ. FT. INSULATION R VALUES .FLOOR 0 ..CEILING 30 ..WALL 11 AREA NORTH WINDOWS 24 SQ.FT. PERCENT OF AREA 1.753105 AREA EAST WINDOWS 109 SQ.FT. PERCENT OF AREA 7.962016 AREA SOUTH WINDOWS 65 SQXT. PERCENT OF AREA 4.747991 AREA WEST WINDOWS 22 SQ.FT. PERCENT OF AREA 1.607012 AREA SKYLIGHTS 0 SQ.FT. PERCENT OF AREA 0 TOTAL WINDOW AREA 220 SQ.FT. PERCENT OF AREA 16.07012 THE U VALUE OF THE WINDOWS IS .65 DUAL PANE THIS BLDG USES DRAPES & FLAT SHADING DEVICES* ON WINDOWS (*mini -blinds, rollar shades, venetian blinds or vertical blinds) THE TOTAL S.C. OF THE WINDOWS IS 0.30 SOUTH OVERHANG LENGTH 2 INTERIOR THERMAL MASS AREA = 300 SQ. FT. ATTIC AREA = 1369 SQ FT INFILTRATION (STD 0.018, MED 0.014, TIGHT 0.012) = .014 HEAUNG LOSSES FOOTING LOSSES... 5281.298 BTU CEILING LOSSES... 1347.27 BTU WINDOW LOSSES.. 4433 BTU WALL LOSSES.... 2472.285 BTU INFILTRATION LOSSES... 4753.169 BTU TOTAL HEAT LOSSES BTU/HR.. 18287.02 ' GAS FURNANCE SIZE 37463.13 BTU OR 45,000 BTU COOLING LOSSES INFILTRATION LOSSES... 6133.12 BTU FOOTING LOSSES... 6814.578 BTU CEILING LOSSES... 1738.413 BTU WINDOW LOSSES... 18015.05 BTU WALL LOSSES..., 3183.645 BTU INFILTRATION LOSSES... 6133.12 BTU NO. OF PEOPLE... 5 COOLING LOSSES... 2000 KITCHEN... 1500 BTU DUCT LOSSES INCLUDED IN TOTAL TOTAL COOLING LOSSES 39384.81 BTU COMPLIANCE CHECK LIST PER DESIGN DATA SLAP OR FLOOR , -4 POINTS MALL INSULATION, _.F, POINTS CEILING INSULATION, --4 POINTS ATTIC, 4 POINTS NORTH WINDOWS GLAZING ^ POINTS EAST WINDOWS GLAZING -10 POINTS SOUTH WINDOWS GLAZING POINTS WEST WINDOWS GLAZING 6 POINTS SKYLIGHT GLAZING 0 POINTS EAST SHADING COEFFICIENT --4 POINTS SOUTH SHADING COEFFICIENT --1 POINTS WEST SHADING COEFFICIENT --1 POINTS NORTH SHADING COEFFICENT 0 POINTS SKYLIGHT SHADING COEFFICIENT 0 POINT i INFILTRATION =1 POINTS h THERMAL MASS ZOO SQ. FT . 8 POINTS OUT1-1 OVERHAND 2 FT. 0 POINTS GAS FURNANCE 71 SE AND REFRIGERATION COOLING THE EER OF THE COOLING SYSTEM IS 9.100001. COOLING 9 POINTS THE ALLOWABLE POINTS PER AD 163 IS -4 FOR AREA 15 THE TOTAL POINTS ARE -4 THE FOLLOWING MANDATORY FEATURES/DEVICES ARE REPUIRED PERCAC TITLE 24 ELECTRIC RE=SISTANCE WATER HEATING NOT PERMITTED INSULATION AS SPECIFIED: PER MANUFACTURES LADLE INFILTRATRION CONTROL. DOORS, WINDOWS FULLY WEATHER^TRIPPED OPENINGS CAULKED AND SEALED AROUND JOINTS I N WINDOW AND WALL SOLE PLATES AND ELECTRICAL OUTLET PLATE GASKETS MANUFACTURED DOORS SHALL MEET APPLICABLE STANDARDS BACK DRAFT DAMPERS ON EXHAUST FAN FIREPLACES MUST HAVE TIGHT FITTING , CLOSEABLE DOORS COVERING FIREBOX PROVIDE COMUST I ON A I. R INTAKE DUCTS (6 SGS . I N " ) WITH TIGHT FITTII'•.IG DAMPER DUCTS; BUILT PER `CHAPTER 10 U. M: C. GAS FURNANCE S T. ZA TO 1 . Z DESIGN LOSS+1 0 BTUH PEP GO. FT „ OR 43,000 BTU SETBACK THERMOSTATS SHALL HAVE AUTOMATIC SETBACK CAPABILITY /2 PERIODS PER 24 WATER HEATER TO HAVE R-12 INSULATION WRAPPIPIG, AND R-7 ON FIRST 5 ' OF PIPE PIAT. GAS STOVES SF -TALL NOT HAVE CONT. PURN I NO PILOTS') LIGHT I N KITCHEN AND PATH TO FSE::: FLOURE'CENT , EXCEPT PATH MIRROR I : I T SINK, TAnLE CERT I F I ED E+Y Ono ShGonic 1 -----_ �� ---_-- --_--_