05-1343 (SFD) Title 24TITLE 24 REPORT Title 24 Report for: MTB, Inc Avenida Carranza La Quinta, CA 92253 5/- 11105'466o CAfEMA14ZA Project Designer: Mark Tuvell 11 Report Prepared By: Jason Campanella 50-855 Washington St. #149 La Quinta, CA 92253 (760) 590-9501 Job Number: 0005 Date: 3/21/2005 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATEY- /A -'5 BY -S -Z- 0 © FF�C& The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 0005 User Number: 5961 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2.R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary R 1 2 3 6 8 12 13 EnergyPro 3.1 By EnergySoft Job Number: 0005 • User Number: 5961 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R MTB, Inc 3/21/2005 Project Title Date Avenida Carranza La Quinta Project Address Building Permit # Jason Campanella (760) 590-9501 Plan Check ! Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,778f? Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 1,778 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor FENESTRATION Shading Devices Type Orientation Area Const. Fenestration Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-15 Wall (W.15.2x4.16) Wood 0.081 Exterior Wall R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U - Factor Shading Yes / No Yes / No Front 33.4 0.74 0.66 Bug Screen ❑ X❑ ❑ ❑X Front 4.5 0.46 0.37 Bug Screen ❑ X❑ ❑ x❑ Left 32.0 0.61 ' 0.39 Bug Screen ❑ X❑ ❑ ❑x Left 12.0 0.46 0.37 Bug Screen ❑ x❑ ❑ ❑X Rear 6.0 0.61 0.39 Bug Screen❑ X❑ ❑ x❑ Rear 12.0 0.46 0.37 Bug Screen❑ X❑ ❑ ❑x Rear 33.4 0.74 0.66 Bug Screen ❑ x❑ ❑ a Right 33.4 0.74 0.66 Bug Screen ❑ X❑ ❑X❑ Right 26.7 0.46 0.37 Bug Screen ❑ x❑ ❑ ❑x Right 72.0 0.61 0.39 Bug Screen ❑ x❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 03/21106 22:04:23 Run Code: 111147 463 Ener Pro 3.1 By Ener Soft User Number: 5961 Job Number: 0005 Page: 3 of 13 Certificate of Compliance: Residential (Part 2 of 2) . CF -1 R MTB. Inc 3/21/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heatingg Equipment Minimum Type and Duct or Type (fumace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 92% AFUE Ducts in Attic 4.2 Setback HVAC System Cooling Equipment Minimum' Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Setback HVAC q tam WATER HEATING SYSTEMS Water Heater Water Heater System Name Type Distribution Type Rated 1 # in Input Syst. Btu/hr Tank Cap. (gal) Energy Fact! 1 Extemal or Recovery Standby Tank Insul. Efficiency Loss (%) R -Value STATE S••-52-1 HP Heat Pump_ Standard 1 15-359 —47 1.90 n/a- n/a For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 BbAr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Mark Tuvell Address: Telephone: Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: . EneravPro 3.1 By EneravSof User Number: 5961 (date) Name: Title/Firm Address: Jason Campanella 50-855 Washington St. #149 La Quinta, CA 92253 Telephone: (760) 590-9501 /� G (si ature) � ' date) /I Job Number: 0005 4of13 Certificate of Compliance: Residential (Addendum) CF -1 R MTB, Inc 3/21/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Plan I Field provider. The KERS rater must document the field verification and diagnostic testing of these measures on a form CF -61R. Plan Field The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. 1 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number. 0005 Pane:5 of 13 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures `§150(.): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does 1^1 not apply to exterior mass walls). E] ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no Elgreater than 2.0 punch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116.17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. El§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ® §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. a§1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0005 Page:6 of 13 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X❑ -§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181 A, or UL181 B. If mastic or tape is used to seal openings greater than 114 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4, Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36' of pipe between finer and heater for future solar, cover for outdoor pools or spas. a. At least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑§118 (f): Cool Roof material meet specked criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumensAvatt or greater for general lighting in kitchens. This general fighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 IumensMratt or greater switched at the entrance to the room or one of the aftemative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5961 Job Number: 0005 Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R MTB Inc 3/21/2005 Project Title Date Avenida Carranza La Quinta Project Address Building Permit # Jason Campanella (760) 590-9501 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 0.83 Facing North Margin ❑ ❑ Facing East Margin _Q Facing South Margin Facing West Margin 0.16 0.67 0.28 0.55 0.11 0.73 0.05 0.78 Space Cooling 31.85 29.13 2.72 26.76 5.09 M 30.28 1.57 30.73 1.12 Domestic Hot Water 14.06 11.31 2.75 ❑ 11.31 2.75 11.31 2.75 ❑ 11.31 2.75 40.60 6.14 38.35 8.39 41.70 5.04 42.08 4.66 Totals 46.74 HH This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 1,778 ft 2 Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 14.9% Number of Dwelling Units: 1.00 Total Conditioned Volume: 16,002 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 1,778 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC System 77s 1_ 6,_.nm gyp_ Cnnditioned Seffiark -2 n/ OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Wall _ 124 0 081 _0 go Wall- 388 0.081 An _go Wall 318 0.081 180 _g0 Wall 309 0.081 270 90 Roof 1 778 0.024 270 ®❑ ❑ ❑ ❑ R-15 Wall ON 15 2Y4 16) 1st Flnnr _15 all (jN 15 2Y4 1 1St Flnnr R_15Wall t1L11152Y41F) 1stEinnr R-15 Wall Opl_15 2Y4 16) 1 st Flnnr R-38 Ronf (R 38 2Y4 24) 1ct Finnr _Q El ❑ M ❑ ❑ ❑ ❑ ❑ HH 00 °❑❑ ❑❑ Run Initiation Timea 0 •0Run Code: 1111471463 3.1 By EnergySoft User Number. 5961 0005 Page:8 of 13 Computer Method Summary (Part 2 of 3) C -2R MTB, Inc 3/21/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1 Window Front (North) 33.4 0.740 0.66 -Q 90 Mtl Thermal Brk Clear Default 1st Floor 2 Window Front (North) 4.5 0.460 0.37 0 90 Mb Thermal Brk Clear Default 1st Floor 3 Window Left (East 16.0 0.610 0.39 90 90 Mtl Thermal Brk Clear Default 1st Floor 4 Window Left (East) 16.0 0.610 0.39 90 90 Mtl Thermal Brk Clear Default 1st Floor 5 Window Left (East) 12.0 0.460 0.37 90 90 Mb Thermal Brk Clear Default 1st Floor 6 Window Rear (South) 6.0 0.610 0.39 180 90 Mtl Thermal Brk Clear Default 1st Floor L Window Rear oath) 12.0 0.460 0.37 180 90 Mb Thermal Brk Clear Default 1st Floor 8 Window Rear (South) 33.4 0.740 0.66 180 90 Mb Thermal Brk Clear Default 1st Floor 6 Window Right oNeo 33.4 0.740 0.66 270 90 Mb Thermal Brk Clear Default 1 st Floor -W Window Right ONe4 26.7 0.460 0.37 270 90 Mb Thermal Brk Clear Default 1st Floor Al Window Right (West) 35.0 0.610 0.39 270 90 Mt! Thermal Brk Clear Default 1st Floor 12 Window Right (West) 12.0 0.610 0.39 270 90 Mtl Thermal Brk Clear Default 1st Floor la Window Right est) 25.0 0.610 0.39 270 90 Mtl Thermal Brk Clear Default 1st Floor INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Buq Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 I EnerovPro 3.1 By EneravSoft User Number: 5961 Job Number. 0005 Paae:9 of 13 1 Computer Method Summary Minimum (Part 3 of 3) C-2R MTB Inc Efficiency and Location 3/21/2005 Project Title Location / pump, etc.) Date THERMAL MASS FOR HIGH MASS DESIGN Comments Central Furnace 92%AFUE Area Thick. Heat 4.2 Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R-Val. Comments Frame WaL Stucco _124 0.88 _21 0"47 R-15 Wall (1N.15.2x4.16) -2 1 st Floor / Exterior Mass Frame Wall. Stucco 388 0_88 21 0_47 R-15 Wall (V1/.15.2x4.16) 2 1 st Floor/ Exterior Mass Frame Wall Stucco 318 0,88 21 0.47 R-15 Wall (W.15.2x4.16) _ 2 1 st Floor/ Exterior Mass Frame Wall. Stucco 309 0_88 21 0.47 R-15 Wall (W.15.2x4.16) 2 1st Floor/ Exterior Mass PERIMETER LOSSES F2 Insulation Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 92%AFUE Ducts in Attic 4.2 Setback HVAC System Pipe Pipe Hydronic Piping Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12.0 SEE $ Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater, Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. STATE S"-52-1 HP Heat Pump Standard 1 15,359 47 1.90 n/a n/a 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 03/21/05 22:04:23 Run Code: 1111471463 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number. 0005 Page:10 of 13 Computer Method Summary (Addendum) C -2R MTB, Inc 3/21/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. I EnerpvPro 3.1 By EnergySoft User Number: 5961 Job Number. 0005 Paoe:11 or 13 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE MTB Inc 3/21/2005 SYSTEM NAME FLOOR AREA HVAC System 1,778 Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sgft) 31.5 Cooling System Output per System 35,000 Total Output (Stub) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sqft) 19.7 Total Output (sgftrron) 609.6 Air System CFM per System 1,300 Airflow (cfm) 1,300 Airflow (cfm/sqft) 0.73 Airflow (cfmrron) 445.7 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 OF 69.1 OF Outside o cfm Supply Fan 1300 cfm 69.1 OF 11.0 / 77.6 of o—> —7 utside Air 0 cfm 79.2/69.4 of M Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11 COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 2,640 33,563 4,177 627 25,780 0 1,678 1,289 0 0 0 0 0 0 0 0 1,678 1,289 36,9191 4,1771 BDP CO. 563AN036-A 19,884 13,752 Total Adjusted System Output19,884 13,752 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 69.1 of n 109.5 of Heating Coil k R'etum Air Ducts 4 79.2 / 69.4 of 79.2 / 69.4 of 64.8 / 64.1 of Supply Fan Cooling Coil 1300 cfm User Number: 5961 Retum Air Ducts Job Number. 0005 56,000 56,000 Jan 12 am Supply Air Ducts 108.6 of ROOMS 70.0 OF I P- Supply Air Ducts 66.1 / 64.5 of 64.4% R.H. ROOMS 78.0/69.1OF 12 of 13 ROOM LOAD SUMMARY PROJECT NAME MTB, Inc DATE 3/21/2005 SYSTEM NAME HVAC System FLOOR AREA 1,778 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE 1 st Floor 1 st Floor 1 2,640 33,563 4,177 2,640 33,563 4,177 627 25,780 PAGE TOTAL 1 2,640 33,563 4,177 627 25,780 TOTAL 1 2,640 33,563 4,177 627 25,780 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0005 Page: 13 of 13