15720 (BLCK) Title 24TITLE 28 REPORT FOR: CORONEL CONST. OFFICE ADDITION LA QUINT&, CAL. PROJECT DESIGNER: CORONEL CONSTRUCTION P. O. BOX 389 LA QUINTA, CA. 92253 REPORT PREPARED BY: WENDELL W. VEITH INSU-FORM, INC. 68487 HIGHWAY 111, SUITE 56 CATHEDRAL CITY, CA 92264 (619) 324-0216 JQb Number: Date: .9/10/1997 G The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. This program developed by Gabel Dodd Associates (510) 428-0803. I. I Table of Contents for Title 24 Report ----------------------------- Cover Page.......................................................... 1 Table of Contents 2 Form ENV -1 Envelope Certificate of compliance ........................ 3 Form ENV -2 Envelope Summary ........................................ 5 Form ENV -3 Construction Assemblies .................................. 8 Form LTG -1 Lighting Certificate of Compliance ........................ 11 Form.LTG-2 Lighting Compliance summary .............................. 13. Form MECH-1 Mechanical Certificate of Compliance 14 Form MECH-3 Mechanical Equipment Summary .... 17 HVACZone & Space Loads Summary ..................................... 18 e 320 P. 04 CERTIFICATE OF COMPLIANCE (part 1 of 2) ENV -1 page 3 of 19 ------------------;------------- - -- ----------------------�-- Project Name: CORONEL CONST. OFFICE ADDITION - Date: 9/10/1997. Address: Envelope LA QUINTA, CAL. Building Permit No Designer: CORONEL CONSTRUCTION Checked :by / Date Documentation: INSU-FORM INC. COMPLY 24 user 2655 ---------------------------,---------------- ------------------------- ---- GENERAL INFORMATION Date of Plans: Building conditioned Floor Area: 500 sf, Building Type: Nonresidential Climate Zone: 15 Phase of Construction: O New Construction O Addition O Alteration Method of Envelope Compliance: Performance - COMPLY 24 v 4.11 STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Part 6, Chapter 1 and Title 20, Chapter 2, Subchapter 4, Article i of the California Code of Regula- tions. This certificate applies only to building envelope requirements. The Principal Envelope Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in sections 110, 116 through 118, and 143 or 149 of Tittle 24,. Part 6, Chapter 1. Please check one: O I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a -.civil engineer or architect. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537,2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform, 0 I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reason: PRINCIPAL ENVELOPE DESIGNER CORONEL CONSTRUCTION lgna ure) (Lic.. ig) `., (Date) ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures: 5EP-10-57 THU 14:L0 HAVE A NICE DAY!! 615 320 9887 F.t-D5 CERTIFICATE OF COMPLIANCE (part 2 of 2) ENV -1 page 4 ----------------------------------------------------------------------- Project Name: CoRONEL CONST. OFFICE ADDITION Date: 9/10/1997 Documentation: INSU-FORM, INC. COMPLY 24 User 2655 ------------------------ ------------------------------------------------- .OPAQUE SURFACES Const Note to .Assembly -Name Type Location/Comments Field ->------------------------ ------ R-13 Wall (W.13.2x4.16) Wood - R-38 Roof (TRUSSES) Wood Solid Wood Door None FENESTRATION Frame orient Panes Type Exterior shade ----------------------- OH Glazing Type Left. (N) 2 Metal Standard Bug Screen -- Y --------------.---------- Double Clear Default(N) Back (E). 2 Metal Standard Bug Screen Y Double Clear Default(N) Front (W) 2 Metal None Y Double Clear Default(N) SEP -10-97 THU 14:20 HAVE A NICE DAY!! 619 320 9887 P.06 r PERFORMANCE ENVELOPE SUMMARY Part 1 of 3 ENV -2 Paige 5 of 19 -----------------------------------------------------------------•---------- Project.Name: CORONEL CONST. OFFICE ADDITION Date: 9/7.0/1997 Documentation: INSU-FORM, INC. COMPLY 24: User 2655 GENERAL INFORMATION BY SPACE. FIr Floor Display Space Name Occupancy No Area Volume Perim. ----------------------- ---------------------- --- ----- ------- ------- OFFICE ADDITION Comp Bldg Office 1 500 '4000 0 k----- Total 500 0 SEP -10-97 THU 14:21 HAVE A NICE DAY!! 619 320 9887 P.07 PERFORMANCE ENVELOPEFart 2 of 3 ENV -2 g 6 of 19 SUr1MARY a page -- --------------...- •----------------- Project Name: -------------------------------- CORONEL CONST. OFFICE ADDITION Date: 9/10/1997 Documentation: INSU-FORM, INC. COMPLY 24 User 2655 OPAQUE SURFACES Act Solar Type Area U -Val Atm Tilt Gains Form 3 Reference Location/Comments Wall 125 0.088 270 90 Yes R-13 Wall (W.13.2x4.15) OFFICE ADDITION Wall Wall 200 0.088 180 . 90 . Yes R-13 Wall (W.13.2x4.16) OFFICE ADDITION Wall 120 0.088 90 90, Yes, R-13 Wall. (W.13.2x4.16) OFFICE ADDITION Wall 175 0.088 0 90 Yes, R-13 Wall (W.13.2x4.'16) OFFICE ADDITION Roof 500 0.029 270 22 Yes R-38 Roof (TRUSSES) OFFICE ADDITION Slb 500 0.000 0 180. No .OFFICE Exposed Slab OFFICE ADDITION PERFORMANCE ENVELOPE SUMMARY Part 3 of 3 ENV -2 page -7 0f 19 -------------------------------------------------- Project Name: CORONEL CONST. OFFICE ADDITION Date: 9/1.0/1997 Documentation: INSU-FORM, INC. COMPLY 241 User 2655 ---------------------------------------------------------------------------- FENESTRATION SURFACES SC Act Glass 0 Type Area Frame Div U -Val Azm Tilt Only Location/Comments -- --- ---- ----- 1 Wdw Front (W) 7.5 Metal No 0.72 270 90 0.88 OFFICE'ADDITION 2 Wdw Front (W) 7.5 Metal No 0.72 270 90 0.88 OF'F'ICE ADDITION 3 Wdw Hack (E) 40.0 Metal No 0.76 90 90 0.88 OFFICE ADDITION 4 Wdw Left (N). 25.0 Metal No 0.77 0 90 0.68 OFFICE ADD]:TION OVERHANGS/SIDE FINS --Window-- -----Overhang------ ---Left Fin--- ---Right: Fin -- if Type Ht Wd Len Ht LExt RExt Dist Len Ht Dist Len Ht .. ---- ---- ---- ---- --- - ---- 1 Wdw 5.0 1.5 4.0 0.1 4.0 4.0 2 Wdw 5.0 1.5 4.0 0.1 4.0 4.0 3 Wdw 6.7 6.0 10.0 0.1 10.0 10.0 4 Wdw 5.0 5.0 2.0 0.1 2.0 2.0 r• aq;LY HAVE A NICE DAY!! w ir.�r�� ". ■w r� nr619 320 9887 P.09 PROPOSED CONSTRUCTION ASSEMBLY ENV_3 page 8 of 19 --------- r------------------------------- ------------------------•--------- Project Name: CORONEL CONST. OFFICE ADDITION Date: 9/10,11997 Documentation: INSU-FORM, INC. COMPLY 24 User 2655 COMPONENT DESCRIPTION ------------------------------- Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly Name: R-13 Wall (W.13.2X4.16) Assembly Type: Wall Assembly Tilt: 90 deg (Vertical) Framing Material: Wood Framing Spacing: " 0. C. Framing Percent: 15.0 4 Absorptivity: 0.70 Roughness: Stucco, Wood Shingles ADJUSTMENT FOR FRAMING (1 /14.53) X (0.85) + (1 / 5.00) X (0.15) Weight: Heat Capacity: 12.3 lb/sqft 2.87 0.088 TOTAL U -VALUE - TOTAL R -VALUE 0.088 11.30 Th R• -Value Construction Components Fr (in) Cavity Frame Outside Air Film 0.17 - ~ 0.17 1. Stucco 0.875 0.17 0.17 2. Membrane, Vapor -Permeable Felt 0.010 0.06 0.06' 3. Insulation, Mineral Fiber, R--13 * 3.500 13.00 3.46 4. Gypsum or Plaster Board 0.500 0.45 0.45 5. 6. 7. 8. - 9. Inside Air Film --------------------------------------------------------------------------- 0.68 0.68 Unadjusted R -Values 14.53 5.00 ADJUSTMENT FOR FRAMING (1 /14.53) X (0.85) + (1 / 5.00) X (0.15) Weight: Heat Capacity: 12.3 lb/sqft 2.87 0.088 TOTAL U -VALUE - TOTAL R -VALUE 0.088 11.30 •� •�� nr�vc H N1i E L _ 20 98$7 P. 10 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 pago 9 of 19 --------------------------------------------- -------------.-.---------v - Project Name: CORONEL CONST, OFFICE ADDITION Date: 9/10/1997 Documentation: INSU-FORM, INC. COMPLY 24 User 2655 ----.... ----------------------------------- -----. ------------ COMPONENT DESCRIPTION Assembly Name: R-38 Roof (TRUSSES) ------------------------------- ------------------------------- Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly Type: Roof Assembly Tilt: 22 deg (Tilted Up) Framing Material: Wood Framing Spacing: ^" O.C. Framing Percent: 10.0 $ Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles TOTAL R -VALUE = 34.94 Weight: 14.3 lb/sgft Heat Capacity: 4.47 Th R• -Value construction Components ---------------------------------------------------------------------------- Fr (in) Cavity Frame Outside Air Film 0.17 0.17' 1. Roofing, Slate 0.500 0.05 0.05 2. Membrane, Vapor -Permeable Felt 0.01.0 0.06 0.06 3. Plywood 0.500 0.62 0.62 4. Air Space * 2.000 0.78 1.98 5. Insulation, Mineral Fiber, R-38 * 11.500 38.00 11.39 6. Gypsum or Plaster Board 0.500 0.45 0.45 7. 8. 9. Inside Air Film 0.61 0.61 --------------------------------------------------------------------------- Unadjusted R -Values 40.74 15.32 ADJUSTMENT FOR FRAMING (1 /40.74) x (0.90) + (1 /15.32) X (0.10) 0.029 TOTAL U -VALUE = 0,.029 TOTAL R -VALUE = 34.94 Weight: 14.3 lb/sgft Heat Capacity: 4.47 SEP -10-97 THU 14:23 HAVE A NI Y!! - 619 320 9887 P.11 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 10 of 19 -------------- ~---------- Project Nazae:CORONELCONST OFFICE ADDITION - [)ate 9/10/1997 --r Documentation: INSU-FORM, INC. COMPLY 24 User 2655 --------------------------------------- COMPONENT DESCRIPTION Assembly Name: Solid Wood Door, ------------------------------- Sketch of Construction Assembly Assembly Type: Door Assembly Tilt: 90 deg (Vertical) Framing Material: None Framing Spacing: �" O.C. Framing Percent: 0.0 Absorptivity: 0.70 Roughness:*Glass, Paint on Pine ASSEMBLY U -VALUE Th R: -Value construction Components Fr (in) Cavity Frame ------------------------------------------------- Outside Air Film 0.17 0.17 1. Softwood, Douglas Fir -Larch 1.750 1.73 1.73 2. 3.' 4. 5. 6. 7. 8. _ 9. Inside Air Film 0 68 ------------------------------------ -----------68------- - --- Unadjusted R -Values 2.58 2.58 ADJUSTMENT FOR FRAMING (1 / 2.58) x (1.00) + (1 / 2.58) x (0.00) - Weight: Heat Capacity: 5.1 lb/sqft 1.99 0.387 TOTAL U -VALUE TOTAL R -VALUE = 0.387 2.58 :ti. r.n vc H N1 t_; CERTIFICATE OF COMPLIANCE (part 1 of 2) LTG -1 page 11 of 19 ---------------------------------------------- -------------------- I ----_---- Project Name: CORONEL CONST. OFFICE ADDITION Date: 9/10/1997 Address: LA QUINTA, CAL. Lighting Designer: CORONEL CONSTRUCTION Building Fsrmi-No Checked by / Date Documentation: INSU-FORM, INC. COMPLY 24 User 2655 --------------------------------------------------------------------------- GENERAL INFORMATION Date of Plans: Building Conditioned Floor Area: 500 sf Building Type: Nonresidential Climate Zone: 15 Phase of Construction: O New Construction 0 Addition 0 Alteration Method of Lighting Compliance: Performance - COMPLY 24 v 4.11 STATEMENT OF COMPLIANCE This Certificate of -Compliance lists the building features and performance specifications needed to comply with Title 24, Part 6, Chapter 1 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Code of Regula- tions. This certificate applies only to building lighting requirements. The Principal Lighting Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance Forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in sections 110, 119, 130 through 132 and 146 or 149. Please check one: 0 I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign .this document as the person responsible for its preparation; and that I am a civil engineer, electrical engineer or architect. 0 I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reaso . PRINCIPAL LIGHTING DESIGNER ��a CORONEL CONSTRUCTION (Si e} (i.�c. ) (Date) ti. LIGHTING MANDATORY MEASURES indicate location on plans of Note Block for Mandatory Measurers: -•�� � n v C M 1 CERTIFICATE OF COMPLIANCE (part 2 of 2) LTG -1 page 12 of 19 - - e ------ S --------------------------------------- ---------------------------- Project ------------------------- Project Name: CORONEL CONST. OFFICE ADDITION Date: 9/1011997 Documentation: INSU-FORM, INC. COMPLY 24 User 2655 --------------------------------------------------------------------------- INSTALLED LIGHTING SCHEDULE No of Watts/ Ballast Ballasts/ No of Note -to - Nave Lamp Type ---------------- Lamps ------ Lamp ------ Type ---------- Luminaire --------- Fixt. Field ------- Fluorescent 1 34 Standard 1.0 1 Incandescent 1 75 n/a n/a 3 Incandescent 1 100 n/a n/a 4 MANDATORY AUTOMATIC CONTROLS Control Note.to Control Location ID Control Type Space Controlled Field CONTROLS FOR CREDIT Control Note to Control Location ----------- ------- ------- ID Control ---------------- Type Space ---------------------- Controlled Field `------ P-10-97 THU 14:24 HAVE.A NICE DAY!! 619 320 9887 P.14 LIGHTING COMPLIANCE SUMMARY LTG -2 page 13 of 19 -------------------------------------------------- --- ----------- --------- Project Name: CORONEL CONST. OFFICE ADDITION Date: 9/10/1997 Documentation: INSU-FORM, INC. COMPLY 24 User 2655 --.: ------------------------------------------------------------------------ ACTUAL LIGHTING POWER No of Watts Total Name Description Lumin per Default Watts 48" T-12 Low Watt /I Lamp (Not Tndm) 1 43.0_ 43 75 w Surface Mount Incandescent 3 75.0 _ 225 100 w Surface Mount Incandescent 4 100.0 400 SubTotal 668 Less Control Credits (LTG -3) 0 Total Proposed Watts 668 * If not CEC Default value,please provide supporting documentation. MODELLED LIGHTING POWER BY SPACE Modelled Floor LPD Total Tailored Space Name Occupancy Area (w/sf) (watts) (watts) OFFICE AUDITION Comp Bldg Office 500 1.500 750 0 --- ----- ----------------- TOTALS 500 1.500 750 0 * Note: Tailored Allotment requires supporting documentation on form LTG -4. CERTIFICATE OF COMPLIANCE (part 1 of 3) MECH-1 page 14 of 19 Project Name: CORONEL CONST OFFICE ADDITIONDate: 9/10/1997 i Address: LA QUXNTA, CAL. Mechanical Designer: CORONEL CONSTRUCTION Building Permit No checked b,y / Date Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655 --------------------------------------------------------------------------- GENERAL INFORMATION. Date of Plans: Building Conditioned Floor Area: 500 sf Building Type: Nonresidential Climate Zone: 15 Phase of Construction: O New Construction O Addition O Alteration Method of Mechanical Compliance: Performance - COMPLY 24 v 4.11. Proof of Envelope Compliance: O Previous Permit, O Compliance Attached STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Part 6, Chapter 1 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Code of Regula- tions. This certificate applies only to building mechanical requirements. The Principal Mechanical Designer hereby certifies.that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in sections 110 through 115, 120 through 124, 140 through 142,144 and 145. Please check one: 0 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as. the person responsible for its preparation; and that I am a civil. engineer mechanical engineer or architect. O I affirm that I am eligible under the exemption to Division 3. of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. 0 I affirm that I am eligible under the exemption to Division 2, of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following rea on: PRINCIPAL MECHANICAL DESIGNER / CORONEL CONSTRUCTIONal �k/), ? lgna ure) (L1c.) (Date) MECHANICAL MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures: ` CERTIFICATE OF COMPLIANCE (part 2 Of 3) MECH--1 page 15 of -19 --------------------------------------------------------------------------- Project Name: CORONEL CONST. OFFICE ADDITION Date: 9/10/1997 Documentation: INSU--FORM, INC. COMPLY 24 User 2655 ----------------------------------------------------------------- SYSTEM FEATURES Zone Name OFFICE ADDITION Time 'Control -------------------------------------------------- Time Control Setback Control Both # of isolation Zonesn/a HP Thermostat Yes Electric Neat 5.0 KW Fan Control Constant Volume VAV Min Position n/a Simul. Heat/Cool n/a Heat Supply Reset Constant Temp Cool Supply Reset Constant Temp ventilation OA Damper Control Economizer Type No Economizer Outdoor Air CFM 75 Heat Equip Type Heat Pump Make & Model No. Day&Night 693CN024-A Cool Equip Type DX Make and Model Note to Field Code 'fables -------------------------------------------------- Time Control Ventilation OA Damper .. S:Prog Switch B:Air Balance A:Auto O:Occ Sensor C:OA Cert. G:Gravity H: kllAn Timer M: OA Measure D:Demand Cont N:14atural 387 P. 04 CERTIFICATE OF COMPLIANCE (part 3 of 3) MECH-1 page 16 of 19 Project Name: CORONEL CONST. OFFICE ADDITION Date: 9/10/1997 Documentation: INSb -FORM, ----------------------- 7 INC. -------------------------------------------------- --------------- --------- COMPLY ----------------------- 24 User 2655 DUCT INSULATION DUCT Duct Tape Insul Note to System Name Type Duct Location Allowed R -Val Field Day&Night 693CN024-A Heating ~ Ducts in Attic ~ Y / N 4:2 Cooling Ducts in Attic Y / N 4.2 PIPE INSULATION Insul Note to System Name Pipe Type Required Field Domestic Hot Water Y / N NOTES TO FIELD - For Building Department Use Only --------------------------------------------------------------------------- 9 •�—� iMV 14:32 HAVE is NICE DAY! 6 1 5 3 2 0 9867 MECHANXCAL EQUIPMENT SUMMARY MECH-3 page 17 of 19 ------------------------------------------ -------------------- ---- Project Name: CORONEL CONST. OFFICE ADDITION Date: 9/10/1997 Documentation: INSU-FORM, INC. COMPLY 24 User 2655 PLANT EQUIPMENT SUMMARY Fuel Elec Total No. Input Input Output Equipment Name Equipment Type Sys .(KBtu) (KW) (KBtu). -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------ ---- ------ Std ----- Std Gas 50 gal or Less Gas Fired 1 40.0 0.0 31.2 CENTRAL SYSTEM SUMMARY Sys No No System Name System Type Sys Economizer Type. 1 Day&Night 693CN024-A Packaged Neat Pu 1 No Economizer CENTRAL SYSTEM RATINGS Sys------- Heating ------------------ ---------------- Cooling ----------- No Type . Output Aux KW EFF Type Output Sensible EER SEER 1 Heat Pump 20800 5.0 7.20 DX 22400 15660 13.90 10.00 CENTRAL FAN SUMMARY ------------- Supply Fan ----------- ---- Return Fan --- SES Mtr Dry Mtr Dry No Fan Type Motor Location CFM BHP Eff Eff CFM Blip Eff Eff 1 Constant Volume Draw -Through 765 0.33 64 100 None ZONAL FAN SUMMARY --------- Zonal Fan ------------ Exhaust Fan ----- -Mtr Dry Mtr Drv- Space Name No CFM BHP Eff Eff No CFM BHP Eff Eff None 0-97 THU 14:36 HAVE A.NICE DAY!! 619 320 9887 P.01' . 4.1 HVAC ZONE HEATING & COOLING LOAD SUMMARY page 18 of 19 -----------------------------------------------------------------•---------- project Name: CORONEL CONST. OFFICE ADDITION Date: 9/1.0/1997 Documentation: INSU-FORM, INC. ICOMPLY 24 User 2655 -------------------------------------------------------------------•---------- HVAC ZONE DESCRIPTION HVAC Zone Name: Heating System Name: Cooling System Name: System Multiplier: Fan Schedule: Peak Load Method: Relative Humidity: SPACES IN THIS ZONE PEAK HEATING OFFICE ADDITION (Jan 12am) .10.977 TOTAL SPACE LOAD 10977 Duct Gains & Losses:. 1098 Ventilation: ( 75 CFM) 3320 Return Air Lighting Gain TOTAL SYSTEM LOAD 15395 SYSTEM OUTPUT AT DESIGN CONDITIONS 31594 OFFICE ADDITION Day&Night 693CN024-A i All On Load Cal.cs COINCIDENT 50 & COOLING PEAK SENSIBLE: LATENT (Aug 3pm) 11399, 400 11399 400 1140 2672 -27' C! 15211. . 373 15089 5581 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool .this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity reguiired to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data.. ..r,c 1v1 L.0 b SPACE HEATING & COOLING LOAD SUMMARY page 19 of 19 ------------------------------------------------------------------..--------- Project Name: CORONEL CONST. OFFICE ADDITION Date; 9/10/1947 Documentation: INSU-FORM, INC. COMPLY 24 User 2655 ---------------------------------------------------------------------------- SUMMARY OF PEAK HOUR LOADS FOR SPACE Space Name: OFFICE ADDITION COOLING DESIGN CONDITIONS HEATING SENSIBLE LATENT Peak Hour: Jan 12am Aug 4pm Indoor Conditions: 70 F DB 78 F DB 50 % RH Outdoor Conditions: 29 F DB 109 F DB 72 F VIB LOAD COMPONENT --------------------- Quantity ------------ Btu/hr ----- Btu/hr ------- Btu/hr --- Wall Conduction 620.0 sqft - 2249 2215 -- Window Conduction 60.0 sqft 2478 1401 Door Conduction 20.0 sqft 318 518 Roof Conduction 500.0 sqft 587 444 Skylight Conduction 0.0 sqft 0 0 Floor Conduction 0.0 sqft 0 0 Slab Conduction 500.0 sqft 3870 0 Interior Conduction 0.0 sqft 0 0 Infiltration 0.5 AC/hr 1475 0 Solar Gain 80.0 sqft 0 2237 Lighting 750.0 watts 0 2482 Receptacle 500.0 watts 0 1707 Process 0.0 watts 0 0 Occupants 2.0 oces 0 500 400 SPACE LOADS 10977 11503 400 Heating AirFlow: 10977 Btu/hr / (1.08 x 35 F DeltaT)] = 291 cfm Cooling AirFlow: 11503 Btu/hr / [1.08 x 23 F DeltaT)) = 463 cfm ,l.