NO PERMIT Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: Custom Residence for Desert Ring, LLC Lot 19A, 52-740 Ross Ave., Madison Club La Quinta, CA 92253 Project Designer: South West Concepts 78-115 Calle Estado La Quinta, CA 92253 (760) 564-4707 Report Prepared by: Tim Scott Scott Design and Title 24, 1 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: Date: 2/20/2013 CITY OF LA QUINTz� BUILDING & SAFETY DEFT. APPROVED FOR CONSTRUCTION; DA W01-1> 13y*tyl�5S [ Z-1 d"-I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. FE-nergyPro 5, 1 by EnergySoR User Number. 6712 Run Code: 2013-02-20T17:10.35 ID: I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 14 HVAC System Heating and Cooling Loads Summary 17 Room Load Summary 23 Room Heating Peak Loads 29 Room Cooling Peak Loads 37 EnergvPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Custom Residence for Desert Ring, LLC Building Type m Single Family ❑ Addition Alone Date ❑ Multi Family ❑ Existing+ Addition/Alteration 1212012013 Project Address Lot 19A, 52-740 Ross Ave., Madison Club California Energy Climate Zone CA Climate Zone 15 Total Cord. Floo 7,394 r Area Addition n/a 7#of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Roof Wood Framed Attic R-38 4,853 Radiant Barrier New Wall Wood Framed R-21 8,277 New Slab Unheated Slab -on -Grade None 4,990 Perim = 622' New Door Opaque Door None 21 New Floor Wood Framed w/Crawl Space R-13 81 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (NE) 289.5 0.350 0.33 none none Bug Screen New Left (SE) 295.1 0.350 0.33 none none Bug Screen New Rear (SW 848.2 0.350 0.33 none none Bug Screen New Right (NVIO 203.0 0.350 0.33 none none Bug Screen New Front (NE) 8.0 0.350 0.33 22.0 none Bug Screen New Front (NE) 45.0 0.350 0.33 11.0 none Bug Screen New Front (NE) 54.0 0.350 0.33 12.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 15.2 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15 0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC 1 Ducted HVAC 2a & 2b Ducted Ducted Attic, Ceiling Ins, vented 8.0 New Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Large Gas 75 0.82 All Pipes Ins New 1 Large Gas 75 0.82 All Pipes Ins New EnergyPro 5.1 by EnBrgySoft User Number. 6712 Run Code: 2013-02-20T17.,10:35 ID: Pane 3 of 46 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Custom Residence for Desert Ring, LLC Building Type m Single Family ❑ Addition Alone Date ❑ Multi Family ❑ Existing+ Addition/Alteration 212012013 Project Address Lot 19A, 52-740 Ross Ave., Madison Club California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7,394 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (fi) Features (see Part 2 of 5) Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15 0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 6 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySaft User Number: 6712 RunCode: 2013.02-20T}7:10:35 ID: Pa e 4 of 46 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Building Type ® single Family ❑ Addition Alone Date Custom Residence for Desert Ring, LLC 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 212012013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White M-1-75S6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 776.0 fP Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 220.0 fl' Exposed Slab Floor. 3.500" thick at Master Bedroom The HVAC System HVAC 2a & 2b must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential A endix RA3.3 must be met. HIGH MASS Design - ft Verify Thermal Mass: 190.0 ' Covered Slab Floor, 3.500"thick at Great RoomlKitcahon N1GH MASS Design - Verify Thermal Mass: 1, 752, 0 ft Exposed Slab Floor, 3.500' thick at Great RoomlKitchen HIGH MASS Design - Verify Thermal Mass: 815.0 IF Covered Slab Floor, 3.500" thick at Bedroom #2 & 3 HIGH MASS Design - Verify Thermal Mass: 124.0 ft2 Exposed Slab Floor, 3.500"thick at Bedroom #2 & 3 The DHW System Bradford White M-1-75SOBN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 4 must serve only Living Areas. The non-Iosabis area between zones cannot exceed 40 sf and each zone must have a se orate thermostat. In addition the air flow ulrements and fan watt draw r uiremenfs in Residential A endix RA3.3 must be met. HIGH MA55 Design -Verify Them7al Mass: 375.0 ft' Exposed Slab Ffoar, 3.500" thick at Gym HIGH MASS Design - Verify Thermal Mass.' 299.0 ft' Exposed Slab Floor, 3.500" thick at Garage HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24HCB636 / 56C VX070 includes credit for a 11.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC i incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 24ABC636 / 58CVX060 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser. The HVAC System HVAC 2a & 2b incorporates HERS Verified Refrigerant Charge or Charge Indicator Display The HVAC System HVAC 2a & 2b incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24HCB636 / 58CVX070 Includes credit fora 11.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge ore Charge indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24HCB660 / 58CVX110 includes credit for a 11.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 Incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Enem vPro 5.1 by Energ ySoft t/serNumbar: 6712 RunCade: 2013-02-20T17:10:35 ID: Page 5 of46 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Custom Residence for Desert Ring, LLC Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 212012013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 375.0 ft2 Exposed Slab Floor, 3.500" thick at Guest Beddroom 1 HIGH MASS Design - Venfy Thermal Mass: 64.0 ft2 Exposed Slab Floor, 3.500" thick at Guest Bedroom 2 The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential A,opendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given, The Cooling System 24HCB624 / 58CVX070 includes credit for a 12.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24HCB660 / 58CVX110 includes credit for a 11.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. FnemvPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-20T17:10:35 ID: Page 6 of 46 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Custom Residence for Desert Ring, LLC ❑ Multi Family ❑ Existing+ Addition/Alteration 212012013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV (kBtu/ft2-_yr) Space Heating 5.85 4.78 1.07 Space Cooling 56.93 5496 1.96 Fans 11.45 1577 -4.31 Domestic Hot Water 4.64 2.98 1.67 Pumps 0.00 0.00 0.00 Totals 78.87 78.49 0.38 Percent Better Than Standard: 0.5 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 65 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 2,395 397 Fuel Available at Site: Natural Gas (SE) Z407 295 Raised Floor Area: 81 (SKO 2,672 848 Slab on Grade Area: 4,990 (NM 2,567 203 Average Ceiling Height: 11.7 Roof 4,853 0 Fenestration Average U-Factor: 0.35 TOTAL: 1,743 Averse SHGC: 0.33 Fenestration/CFA Ratio: 23.6 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author 4� Company Scott Design and Title 24, Inc, 220/2013 Address 77-085 Michigan Drive Name Tim Scott City/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date _ The individual with overall design responsibility hereby certifies that the proposed building design repre nted in this set of construction documents is consistent with the other compliance forms and worksheets, with the sp i cations, and with any other calculations submitted with this permit application, and recognizes that compliance u; g uct design, �g duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sfiali require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) 417-815 Company South West Concepts Address 78-115 Calle Estado Name Stephen Nieto City/State/Zip La Quinta, CA 92253 Phone (760) 564-4707 Signed License # Date Ere Pro 5.1 by Enera Soft user Number: 6712 RunCode: 2013-02-20T17:10.35 ID. Page 7 of 46 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Custom Residence for Desert Ring, LLC Building Type O Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 212012013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulatior Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Roof 996 0.025 R-38 45 0 New 4.2.1-A21 Master Bedroom #1 Wall 212 0.069 R-21 65 90 New 4.3.1-A6 Master Bedroom #1 Wall 192 0.069 R-21 155 90 New 4.3.1-A6 Master Bedroom #1 Wall 237 0.069 R-21 245 90 New 4.3.1-A6 Master Bedroom #1 Wall 535 0.069 1 R-21 335 90 New 4.3.1-A6 Master Bedroom #1 Slab 776 0.730 None 0 180 New 4.4.7-A1 Master Bedroom #1 Slab 220 0.730 1 None 0 180 New 4.4.7-A1 Master Bedroom #1 Roof 820 0.025 R-38 45 0 New 4.2.1-A21 Great Room/Kitchen Wall 382 0.069 R-21 65 90 New 4.3.1-A6 Great Room/Kitchen Wall 304 0.069 R-21 155 90 New 4.3.1-A6 Great Room/Kitchen Wall 722 0.069 R-21 245 90 New 4.3.1-A6 Great Room/Kitchen Door 21 1.450 None 245 90 New 4.5.1-A1 Great Room/Kitchen Wall 289 0.069 R-21 335 90 New 4.3.1-A6 Great Room/Kitchen Slab 190 0.730 None 0 180 New 4.4.7-A1 Great Room/Kitchen Slab 1,752 0.730 None 0 180 New 4.4.7-A1 Great Room/Kitchen Roof 80 0.025 R-38 45 0 New 4.2.1-A21 Bedroom #2 & 3 FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 8.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Master Bedroom #1 2 Window 4.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Master Bedroom #1 3 Window 120.0 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Master Bedroom #1 4 Window 3.0 0.350 NFRC 0.33 NFRC 245 New Dual Nan Metal Tinted Master Bedroom #1 5 1 Window 9.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Master Bedroom #1 6 Window 9.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Master Bedroom #1 7 Wndow 9.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Master Bedroom #1 8 Window 4.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Master Bedroom #1 9 Wndow 8.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Great Room/Kitchen 10 Window 45.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Great Room/Kitchen 11 Window 54.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Great Room/Kitchen 12 Window 45.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Great Room/Kitchen 13 Window 22.5 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Great Room/Kitchen 14 Window 4.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Great Room/Kitchen 15 Window 120.0 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Great Room/Kitchen 16 Window 290.0 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Great Room/Kitchen (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Tyne SHGC Window Ove hang Left Fin Ri Iht Fin -H-g-t7 Wd Len H t LExt RExt Dist Len Hg t (Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10.01 17.0 22.0 0.11 22.0 22.0 10 Bug Screen 0.76 4.01 10.0 11.0 0.1 11.0 11.0 11 Bug Screen 0.76 4.01 6.7 12.0 0.1 12.0 12.0 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76� EnerqyPio 5 1 by EnergySoff User Number: 6712 RunCode: 2013-02-20T17:10:35 ID: Page 8 of 46 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Custom Residence for Desert Ring, LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 212012013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame I Interiorl Frame Wall 250 0.069 R-21 65 90 New 4.3.1-A6 Bedroom #2 & 3 Wall 313 0.069 ,R-21 155 90 New 4.3.1-A6 Bedroom #2 & 3 Wall 123 0.069 .R-21 245 90 New 4.3.1-A6 .Bedroom #2 & 3 Wall 172 0.069 .R-21 335 90 New 4.3.1 A6 .Bedroom #2 & 3 Slab 815 0.730 .None 0 180 New 4.4.7-A1 .Bedroom #2 & 3 Slab 124 0.730 None 0 180 New 4.4.7-A1 .Bedroom #2 & 3 Roof 75 0.025 R-38 45 0 New 4.2.1-A21 G Garage/Guest 1 Wall 130 0.069 R-21 65 90 New .4.3.1-A6 Gym/Garage/Guest 1 Wall 73 0.069 R-21 155 90 New 4.3.1-A6 G m/Gars e/Guest 1 Wall 131 0.069 R-21 245 90 New 4.3.1-A6 G m/Gars a/Guest 1 Wall 327 0.069 R-21 335 90 New 4.3.1-A6 Gym/Garage/Guest 1 Slab 375 0.730 None 0 180 New 4.4.7 Al G m/Gars a/Guest 1 Roof 39 0.025 R-36 45 0 New 4.2.1-A21 G m/Gana e/Guest 1 Wall 130 0.069 R-21 65 90 New 4.3.1-A6 Gym/Garage./Guest 1 Wall 214 0.069 R-21 155 90 New 4.3.1-A6 G m/Gars a/Guest 1 Wall 66 0.069 R-21 245 90 New 4.3.1-A6 G m/Gars a/Guest 1 FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 17 'Wndow 10.0 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Great Room/Kitchen 18 'Wndow 48.0 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Great Room/Kitchen 19 'Window 10.0 0.350 NFRC 0.33 NFRC 2451 New Dual Non Metal Tinted Great Room/Kitchen 20 'Wndow 48.0 0.350 NFRC 0.33 NFRC 1551 New Dual Non Metal Tinted Bedroom #2 & 3 21 IWindow 8.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Bedroom #2 & 3 22 'Wndow 8.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Bedroom #2 & 3 23 'Window 48.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Bedroom #2 & 3 24 'Window 20.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Bedroom #2 & 3 25 'Wndow 40.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Bedroom #2 & 3 26 'Wndow 20.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Bedroom #2 & 3 27 Window 48.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Bedroom #2 & 3 28 Window 16.5 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Gym/Garage/Guest 1 29 IWindow 8.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Gym/Garaga/Guest 1 30 Window 12.6 0.350 NFRC 0.33 NFRC 2451 New dual Non Metal Tinted GymlGaragelGuest 1 31 Window 40.0 0.350 NFRC 0.33 NFRC 2451 New Dual Non Metal Tinted GymlGarage/Guest 1 32 Window 12.8 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Gym/Garage/Guest 1 (1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len HqA LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 .Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bua Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 [Bug Screen 0.76 32 1Buq Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013.02-20717.10:35 ID: Page 9 of46 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Custom Residence for Desert Ring, LLC Type m Single Family ❑ Addition Alone Date ❑ Multi Family ❑ Existing+ Addition/Alteration 1212012013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavit Exterior Frame Interior] Frame. Slab 299 0.730 None 0 180 New 4.4.7-A1 GVm/Gars e/Guest 1 Roof 547 0.025 R-38 45 0 New 4.2.1-A21 Gym/Gana a/Guest 1 Wall 210 0.069 R-21 65 90 New 4.3.1-A6 G m/Gara e/Guest 1 Wall 227 0.069 R-21 155 90 New 4.3.1-A6 Gym/Garage/Guest 1 Wall 204 0.069 R-21 245 90 New 4.3.1-A6 G m/Gara a/Guest 1 Wall 246 0.069 R-21 335 90 New 4.3.1-A6 G mlGara elGuesl 1 Slab 375 0.730 None 0 180 New 4.4.7-A1 G m/Gara e/Guest 1 Roof 465 0.025 R-38 45 0 New 4.2.1-A21 Guest Bedroom 2 Wall 199 0.069 R-21 65 90 New 4.3.1-A6 Guest Bedroom 2 Wall 351 0.069 R-21 155 90 New 4.3.1-A6 Guest Bedroom 2 Wall 195 0.069 R-21 245 90 New 4.3.1-A6 Guest Bedroom 2 Wall 355 0.069 R-21 335 90 New 4.3.1-A6 Guest Bedroom 2 Floor 81 0.046 R-13 0 180 New 4.4.1-A3 Guest Bedroom 2 Slab 64 0.730 None 0 160 New 4.4.7-A1 Guest Bedroom 2 Roof 1,8311 0.025 .R-38 451 0 New 4.2.1-A21 Master Bedroom 2 Wall 486 0.069 R-21 65 90 New 4.3.1-A6 Master Bedroom 2 FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 33 endow 8.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Gym/Garage/Guest 1 34 IWindow 6.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted GymlGaragelGuest 1 35 'Window 40.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted G m/Garage/Guest 1 36 'LMndow 11.3 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted GymlGarage/Guest 1 37 'Window 11.3 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Gym/Garage/Guest 1 38 Yl<ndow 12.8 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted GymlGarage/Guest 1 39 V><ndow 20.0 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Gym/Garage/Guest 1 40 Window 12.8 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Gym/Garage/Guest 1 41 Window 4.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted GymlGarage/Guest 1 42 Window 18.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Guest Bedroom 2 43 Window 18.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Guest Bedroom 2 44 Window 24.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Guest Bedroom 2 45 Window 40.0 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Guest Bedroom 2 46 Window 10.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Guest Bedroom 2 47 Window 10.0 0.350' NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Guest Bedroom 2 48 Window 24.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal 'tinted Master Bedroom 2 (1 ) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2j SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade T e SHGC Window Overhan Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len Hot Dist Len H t 33 ,Bug Screen 0.76 34 ,Bug Screen 0.76 35 Bug Screen 0.76 36 BugScreen 0.76 37 Bug Screen 0.76 38 BugScreen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bu Screen 0.76 46 Buo Screen 0.76 47 Bug Screen 0.76 48 IBug Screen 0.76 Ene Pro5.1 6 Ens Soft User Number: 6712 RanCode: 2013.02-20T17':10:35 ID: Page 10of46 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Custom Residence for Desert Ring, LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 212012013 OPAQUE SURFACE DETAILS Surface Type I Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interiorl Frame Wall 438 0.069 R-21 155 90 New 4.3.1-A6 Master Bedroom 2 Wall 124 0.069 R-21 245 90 New 4.3.1-A6 Master Bedroom 2 Wall 440 0.069 R-21 335 90 New 4.3.1-A6 Master Bedroom 2 1 FENESTRATION SURFACE DETAILS ID Type Area U-Factor'I SHGC Azm Status Glazing Type Location/Comments 49 Window 48.0 0. 3501 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Master Bedroom 2 50 Window 24.0 0.3501 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Master Bedroom 2 51 Window 32.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Master Bedroom 2 52 Window 8.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Master Bedroom 2 53 Window 8.0 0.350 NFRC 0.33 NFRC 65 New Dual Non Metal Tinted Master Bedroom 2 54 Window 4.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Master Bedroom 2 55 Window 4.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Master Bedroom 2 56 Window 42.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Master Bedroom 2 57 Window 16.0 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Master Bedroom 2 58 Window mo 0.350 NFRC 0.33 NFRC 155 New Dual Non Metal Tinted Master Bedroom 2 59 Window 96.0 0.350 NFRC 0.33 NFRC 245 New Dual Non Metal Tinted Master Bedroom 2 60 Window 10.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Master Bedroom 2 61 Window 10.0 0.350 NFRC 0.33 NFRC 335 New Dual Non Metal Tinted Master Bedroom 2 (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin Hcjt Wd Len Hat LExt RExt Dist Len H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 F-� EnergyPro6lbyEnergySoft User Number: 6712 RunCode: 2013.02.20T17:10:35 ID: Page 11 of 46 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Custom Residence for Desert Ring, LLC Building Type ❑ Single Family ❑ Addition Alone Date ❑ Multi Family ❑ Existing+ Addition/Alteration 212012013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area 'ft') Volume Year Built New Existing Altered Removed HVAC 1 Master Bedroom 996 10,956 HVAC 2a & 2b Great RoomR<itchen 1,942 31.072 HVAC 3 Bedroom #2 & 3 939 9,390 HVAC 4 Gym 375 3,750 Garage 299 2.990 Guest Berdroom 1 547 5,470 HVAC 5 Guest Bedroom 2 465 4,650 HVAC 6 Master Bedroom 2 1,831 18,310 Totals 7,3941 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat T De Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC 2a & 2b 2 Central Furnace 80% AFUE Split Air Conditioner 15.2 SEER Setback New HVAC 3 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE I Split Air Conditioner 15.0 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Cooling Duct Location Duct R-Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2a & 2b Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 4 Ducted Ducted Attic, Ceiling Ins. vented 1 8.01 IZI New HVAC 5 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btuh) Tank Cap. (gal Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White M-1-75S6B 1 Large Gas All Pipes Ins 76,000 75 0.82 0.00 % 0.0 New Bradford White M-1-706B 1 1 Large Gas I All Pipes Ins 76,000 75 0.82 0.00 % 0.0 New 1 MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o ¢ System Name Pipe Length Pipe Diameter Insul. Thick. Q [HP Plenum Outside Buried FnetgyPro 5.1 by EnergySoft User Number: 6712 RunCade: 2013-02-20717:10:35 ID: Page 12 of 46 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Custom Residence for Desert Ring, LLC Building Type ❑ Single Family ❑ Addition Alone Date ❑ Multi Family ❑ Existing+ Addition/Alteration 1212012013 BUILDING ZONE INFORMATION Svstem Name Zone Name Floor Area Volume Year Built New Existing Altered Removed Totals 1 7,3941 0 0 0 HVAC SYSTEMS System Name 0 . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 6 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION S stem Name Heating Cooling Duct Location Duct R-Value Ducts Tested? Status HVAC 6 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS Svstem Name City. Ty2e Distribution Rated Input (Btuh) Tank Cap. (al) Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status f MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 i6 v�i Q System Name Pipe Len th Pipe Diameter Insul. Thick. City. HP Plenum Outside Buried EnergyPro 5.1 by EnerqySoft User Number. 6712 RunCode: 2013.02-20T17:10:35 ID Page 13 of 46 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Date Custom Residence for Desert Ring, LLC 212012013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- I R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Materlal. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 1 50: Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 1 13c 5. §115. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 1 12c . §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater, §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recfrculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated.to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(')3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned s ace. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2013-02-20T17:10:35 ID: Page 14 of 46 MANbATORY MEASURES SUMMARY: Residential (Page 2 of 3) MF-1 R Project Name Date Custom Residence for Desert Ring, LLC 1212012013 §150(m)1: All air-distrlbution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and E ui ment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat um or gas heater shall have a raver. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential LiShting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 154(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting In kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-02-20T17:10:35 ID: Page 15 of 46 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3) MF-1 R Project Name Date Custom Residence for Desert Ring, LLC 212012013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §i50(k)11: Permanently installed luminaires tocated in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently Installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting In detached storage building less than 1000 square feet located on a residential site is not req uired to cam I y with 5150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)f 3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occu ant sensors certified to comeIy with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2013-02-20T17:10.35 ID: Page 16 of 46 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence for Desert Ring, LLC Date 2/20/2013 System Name HVAC 1 Floor Area 996 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 537 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 11,069 1,035 240 14,305 Total Output (Btuh) 71,000 0 Output Btuh/s ft 71.3 522 546 Cooling System 0 01 Output perSystem 35,200 0 0 0 0 Total Output (Btuh) 35,200 1,675 1,035 -1.675 Total Output(Tons) 2.9 i 522tj 546 Total Output (Btuh/s ft) 35.3 Total Output s ft/Ton 339.5 1 13,787 13,722 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24HCB636 / 58CVX070 27,450 3,191 71,000 Airflow cfm/s ft 1.20 Airflow (cfm/Ton) 409.1 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 27,450 3,191 1 71.000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 of 70 OF 125 IF 126 OF 0 Heating Coil Supply Fan 1,200 cfm 126 IF FR6*'A 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF Outside Air 0 cfm 78164 IF 78/64°F 57/56°F 58156°F 771 n Cooling Coil Supply Fan 59 / 56 OF 1,200 cfm 45.4 % ROOM —z 78 / i 64 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-20T17:10:35 ID: Page 17 of 46 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence for Desert Ring, LLC Date 2/20/2013 System Name HVAC 2a & 2b Floor Area 1,942 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,482 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 51,000 29,837 2,028 650 28,394 Total Output Btuh 102,000 0 Output (Btuh/s ft) 52.5 1,406 1,084 Cooling System 0 0 Output perSystem 35,500 0 0 0 0 Total Output Btuh 71,000 4,960 2,028 -4.960 Total Output (Tons) 5.9 j 1,4061 1,084 Total Output Btuh/s ft 36.6 Total Output s ft/Ton 328.2 37,609 25,602 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 2,400 24ABC636 / 58CVX060 56,090 5,567 102,000 Airflow cfm/s ft 1.24 Airflow (cfm/Ton 405.6 a Outside Air (/o) 0.0 % Adjusted System Output Total Ad (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 56,090 5,567 102,000 Aug 3 PM I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCH ROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm Ar 70 OF 70OF 110 °F 111 OF Heating Coil Supply Fan 111 OF 2,400 cfm ROOM 70 OF l COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 1121 Outside Air 0 cfm 79 / 64 OF 79164 OF 57 / 55 OF 59 / 56 OF - Cooling Coil Supply Fan 59 / 56 °F 2,400 cfm �y 44.8 % ROOM 78 / 63 OF EnergyPro 5.1 by EnergySoR User Number., 6712 RunCode: 2013-02-20T17:10:35 ID: Page 18 of 46 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence for Desert Ring, LLC Date 2/20/2013 System Name HVAC 3 Floor Area 939 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 534 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 10,954 1,187 213 12,737 Total Output (Btuh) 71,000 0 Output Btuh/s ft 75.6 516 486 Cooling System 0 0 output per System 35,200 0 0 0 0 Total Output Btuh 35,200 1,675 516 13,661 1,187 -1,675 Total Output(Tons) 2.9 486 Total Output (Btuh/s ft) 37.5 Total Output s ft/Ton 320.1 12,034 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24HCB636 / 58CVX070 27,336 3,350 71,000 Airflow cfm/s ft 1.28 Airflow (cfm/Ton 409.1 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 27,336 31350 71,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air Ok 0 cfm 70 of 70 OF 125 °F 127 OF Heating Coil Supply Fan 126 OF 1,200 cfm ROt7M 70 °F COOLING SYSTEM PSYCH ROM ETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF Outside Air 0 cfm 78 / 64 OF 78/64OF 57/56OF 58/56OF Q Cooling Coil Supply Fan 59 / 56 OF 1,200 cfm 45.7 % ROOM 78 / 64 OF f Energ Pro5.1 by EnergySoft User Number.- 6712 RunCode: 2013-02-20T17:10:35 ID: Page 19 of 46 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 2/20/2013 System Name Floor Area HVAC 4 1,221 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 786 Return Vented Lighting COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 110,000 14,249 1.223 386 21,490 Total Output (Btuh) 110,000 0 Output Btuh/s ft 90.1 Return Air Ducts Return Fan Ventilation 0 Supply Fan 671 820 Cooling System 0 0 Output erSystem 55,500 0 0 0 0 Total Output (Btuh 55,500 2,978 -2.978 Total Output (Tons)4.6 Supply Air Ducts 671 820 Total Output (Btuh/s ft) 45.5 Total Output s ft/Ton 264.0 TOTAL SYSTEM LOAD 18,570 1,223 20.153 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24HCB660 / 58CVX110 40,570 8,725 110,000 Airflow cfmis ft 1.64 Airflow (cfm/Ton) 432.4 Outside Air % 0.0 % Total Adjusted System Output 40,570 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK r 8,725 Aug 3 PM 1 110,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 121 OF 123 OF Q' Outside Air 0 cfm Heating Coil Supply Fan 122 OF 2,000 cfm ['"R'.........' OOM 70 OF 44 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Conlin Peaky 112/78IF 78/65OF 59/58OF 61/59OF Outside Air 0 cfm Cooling Coil Supply Fan 61 159 °F 2,000 cfm 49.6 % ROOM 78 165 IF 78165 °F 4 :01, FTA EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-20T17:10:35 ID: Page 20 of 46 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence for Desert Ring, LLC Date 2/20/2013 System Name HVAC 5 Floor Area 465 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 402 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent I CFM Sensible Output perSystem 71,000 7,779 590 94 8,428 Total Output (Btuh) 71,000 0 Output Btuh/s ft 152.7 367 322 Cooling System 0 0 Output perSystem 22,800 0 0 0 0 Total Output (Btuh) 22,800 995 590 -995 Total Output(Tons) 1.9 367 322 Total Output Btuh/s ft) 49.0 Total Output s ft/Ton 244.7 1 9,507 8,077 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 24HCB624 / 58CVX070 17,210 2,864 71,000 Airflow cfm/s ft 1.72 Airflow Wrn/Ton) 421.1 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 17,210 2,864 71,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 153 IF 154 IF Heating Coil Supply Fan 154 OF 800 cfm ...................... ROt7M 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 0 cfm 78164 IF 78/64°F 58/57°F 59158°F Cooling Coil Supply Fan 60 f 5.3 - F 800 cfm 47.7 % ROOM W _ EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-02-20T17:10:35 ID: Page 21 of 46 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence for Desert Ring, LLC Date 2/20/2013 System Name HVAC 6 Floor Area 1,831 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,137 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 110,000 20,145 1,735 320 17,851 Total Output Btuh 110,000 0 Output Btuh/s ft 60.1 949 681 Cooling System 0 0 Output perSystem 55,500 0 0 0 0 Total Output Btuh 55,500 2,978 1.735 -2,978 Total Output (Tons) 4.6 949 681 Total Output Btuh/s ft 30.3 Total Output s ft/Ton 395.9 25,021 16,236 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24HCB660 / 58CVX110 40,304 9,208 110,000 Airflow cfm/s ft 1.09 Airflow cfm/Ton) 432.4 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 40,304 9,208 110,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCH ROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 of 70 OF 121 OF 123 OF Heating Coil Supply Fan 122 IF 2,000 cfm ROOM 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 0 cfm 78 / 65 OF 78/65OF 60/58OF 61/59OF IJ Cooling Coil Supply Fan 61 159 OF 2,000 cfm 50.3 % ROOM 78165 °F EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-20T17.10:35 ID: Page 22 of 46 ROOM LOAD SUMMARY Project Name Custom Residence for Desert Ring, LLC Date 212012013 System Name HVAC 1 Floor Area 996 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Bedroom #1 Master Bedroom 1 537 11,069 1,035 537 11,069 1,035 240 14,305 PAGE TOTAL 1 5371 11,0691.035 240 14,305 TOTAL 1 537 11,069 1,035 240 14,305 ' Total includes ventilation load for zonal systems. Enera Pro 5.1 by EneruvSoft User Number: 6712 RunCode: 2013-02-20T17:10:35 ID: Page 23 of 46 M LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 212012013 System Name Floor Area HVAC 2a & 2b 1,942 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent CFM Sensible GreatRoom/Kitchen GreatRoom/Kitchen 1 1,482 29,837 2,028 1,482 2.9,8371 2,028 650 28,394 PAGE TOTAL TOTAL* 1,462 29.637 2,028 650 28,394 1,482 29,837 2,028 650 28,394 EnergyPro 5 1 by EnergySoft User Number. 6712 Run Co de: 2013-02-24T17:10:35 ID: Page 24 of 46 1 ROOM LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 212012013 System Name Floor Area HVAC 3 939 ROOM LOAD SUMMARY Zone Name Room Name Bedroom #2 & 3 Bedroom #2 & 3 Total includes ventilation load for zonal FnemyFro 5.1 by EneryySaR User N ROOM COOLING PEAK Mult. CFM Sensible Latent 1 534 10,954 1,187 PAGE TOTAL TOTAL* 2 RunCode:2013.02-20T17:10:35 COIL COOLING PEAK CFM Sensible I Latent 5341 10,9541 1,18 COIL HTG. PEAK CFM I Sensible 2131 12,737 534 10,954 1,187 213 12,737 534 10,954 1,187 213 12,737 ROOM LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 212012013 System Name Floor Area HVAC 4 1,221 ROOM LOAD SUMMARY ROOM COOLING PEAK I COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible I Latent CFM Sensible Gym/Garage/Guest 1 Gym 1 271 4,912 314 271 4,912 314 129 7,189 Garage 1 108 1,964 251 108 1,964 251 90 4,994 Guest Berdroom 1 1 407 7,373 658 407 7,373 658 167 9,306 PAGE TOTAL TOTAL" 786 14,249 1,223 386 21.490 786 14,249 1,223 386 21.490 Total includes ventilation load for zonal systems. Ene Pm 5.1 by EnerqVScift User Number: 5712 Run Code: 2013-02-20 T1 7:10:35 ID: F'a a 26 of 46 ROOM LOAD SUMMARY Project Name Custom Residence for Desert Ring, LLC Date 212012013 System Name HVAC 5 Floor Area 465 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM Sensible Latent CFM Sensible Guest Bedroom 2 Guest Bedroom 2 1 402 7, 779 590 402 7,779 590 94 8,428 PAGE TOTAL 1 4021 94 8,428 TOTAL 1 402 7,779 590 94 8,428 * Total includes ventilation load for zonal systems. EnerqyPm 5.1 b y En erg Soft User Number., 6712 Run Co de: 2013-02.20T17:10:35 ID: Page 27 of 46 ROOM LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 212012013 HVAC 6 1 1, 831 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible Master Bedroom 2 Master Bedroom 2 1 1,1371 20,1451 1, 735 1,1371 20,1451 1, 735 320 17, 851 PAGE TOTAL TOTAL* 1,137 20,145 1.7351 320 17,851 1,137 20,145 1,735 320 17,851 * Total Includes ventilation load for zonal systems. EnarqyPtip 5.1 by EnergySoft User Number, 6712 RunCode: 2013-02.20T77:10.35 ID: Page 28 of 46 ROOM HEATING PEAK LOADS Project Name Date Custom Residence for Desert Ring, LLC 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 996.0 ftz Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Attic 996.0 0.0250 44 1,096 R-21 Wall 1,176.0 0.0690 44 3,570 Dual Non Metal Tinted 166.0 0.3500 44 2,556 Slab -On -Grade perm = 118.0 0.7300 44 3,790 Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X Schedule Alr Sensible Fraction through an interior surface 1.064 X 996 X Area another room 11.00 X 0.385 Height ACH Page Total / 60 ] X AT 11,012 = 3,292 14.305 TOTAL HOURLY HEAT LOSS FOR ROOM EnergyPro 5.1 by EnergySott User Number: 6712 RunCode. 2013.02-20T17:10:35 ID: Pace 29 of 46 ROOM HEATING PEAK LOADS Project Name Date Custom Residence for Desert Ring, LLC 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room/Kitchen Floor Area 1,942.0 ft2 Indoor D Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btulhr R-38 Roof Attic 820.0 0.0250 44 902 R-21 Wall 1,696.9 0.0690 44 5,152 Dual Non Metal Tinted 656.5 0.3500 44 10,110 Wood Door 20.6 1.4500 44 1,314 Slab -On -Grade perim = 140.0 0.7300 44 4,497 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an Interlor surface X 1,942 X Area another room 16.00 X 0.265 Height ACH Page Total / 60 X AT 21,975 = 6,419 TOTAL HOURLY HEAT LOSS FOR ROOM 28,394 EnargyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-02-20T17:10.35 ID., Page 30 of 46 ROOM HEATING PEAK LOADS Project Name Custom Residence for Desert Ring, LLC Date 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom #2 & 3 Floor Area 939.0 ftz Indoor Dry Bulb Temperature 70 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x to Ceiling U-Value X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R 36 Roof Attic 80.0 0.0250 44 88 R-21 Wall 658.0 0.0690 44 2,605 Dual Non Metal Tinted 240.0 0.3500 44 3,696 Slab -on -Grade perim = 101.0 0.7300 44 3,244 Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 x 1.064 Schedule Air Sensible Fraction through an interior surface x 939 x Area another room 10.00 x 0.424 Heigh[ ACH Page Total / 60 ] X AT 9,633 = 3,104 TOTAL HOURLY HEAT LOSS FOR ROOM 12,737 EnergyPro 5.1 by EnergySaft User Number: 6712 RunCode: 2013-02-20T17:10:35 ID: Page 31 of 46 ROOM HEATING PEAK LOADS Project Name Custom Residence for Desert Ring, LLC Date 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name GYM Floor Area 375.0 ftZ Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x to Ceiling U-Value X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr P-35 Roof Attic 75.0 0.0250 44 83 R-21 Wall 660.9 0.0690 44 2,006 Dual Non Metal Tinted 90.1 0.3500 44 1,388 Slab -On -Grade perim = 77.0 0.7300 44 2,473 Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 x Schedule Air Sensible Fraction through an interior surface x 375 x Area another room 10.00 x 0.424 Height ACH Page Total / 60 ] X AT 5,950 = 1,240 TOTAL HOURLY HEAT LOSS FOR ROOM 7,189 Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 3013.02-20T17:10:35 ID: Page 32 of 46 ROOM HEATING PEAK LOADS Project Name Date Custom Residence for Desert Ring, LLC 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage Floor Area 299.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Celling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr R-38 Roof Attic 39.0 0.0250 44 = 43 R-21 Wall 409.6 0.0690 44 = 1,244 Dual Non Metal Tinted 16.0 0.3500 44 = 246 Slab -On -Grade perim = 77.0 0.7300 44 = 2,473 = = = = = = = = = = = = = = = = = = = = = = = = = = = 4,006 44 4 988 Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X [711064 Schedule Air Sensible Fraction through an interior surface X 299 X Area another room 10.00 X 0.424 Height ACH Page Total / 60 ] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 4.994 FnRmvPrn 5.1 by EneravSoft User Number. 6712 RunCode: 2013-02.20T17:10:35 ICJ: Page 33 of 46 ROOM HEATING PEAK LOADS Project Name Custom Residence for Desert Ring, LLC Date 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Berdroom 1 Floor Area 547.0 f' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to 1 Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Attic 547.0 0.0250 44 602 R-21 Wall 887.8 0.0690 44 2,695 Dual Non Metal Tinted 112.2 0.3500 44 1.728 Slab -On -Grade perim = 77.0 0.7300 44 2,473 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 54i X Area another room 10.00 X 0.424 Height ACH Page Total / 60 ] X AT 7,498 = 1,808 TOTAL HOURLY HEAT LOSS FOR ROOM 9.306 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-02-20Tf7:10,35 10. Page 34 of46 ROOM HEATING PEAK LOADS Project fame Custom Residence for Desert Ring, LLC Date 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bedroom 2 Floor Area 465.0 ft2 Indoor- Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof Attic 465.0 0.0250 44 512 R-21 Wall 1,100.0 0.0690 44 3,340 Dual Non Metal Tinted 120.0 0.3500 44 1,848 R-19 Floor Crawlspace 81.0 0.0460 44 164 Slab -On -Grade perim = 32.0 0.7300 44 1,028 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 465 X Area another room 10.00 X 0.424 Height ACH Page Total / 60 J X AT 6,891 TOTAL HOURLY HEAT LOSS FOR ROOM 8,4281 En ergyPro 5.1 by En erVySoft User Number.- 6712 RunCode: 2013.02-20T1710:35 ID. Page 35 of 40 ROOM HEATING PEAK LOADS Project Name Custom Residence for Desert Ring, LLC Date 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom 2 Floor Area 1,831.0 ftz Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Attic 1.831.0 0.0250 44 2,014 R 21 Wall 1,488.0 0.0690 44 4,518 Dual Non Metal Tinted 342.0 0.3500 44 5,267 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 1,831 X Area another room 10.00 X 0.424 Height ACH Page Total / 60 ] X AT 11,798 = 6,052 TOTAL HOURLY HEAT LOSS FOR ROOM 17.851 EnergyPro 5.1 by Ens Soft User Number: 6712 RunCode: 2013-02-20T17;10:35 1D. Page 36 of 46 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring. LLC 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 996.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range; 34 OF opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic (NE) 996.0 X 0.0250 X 56.0 = 1,394 R-21 Wall (NE) 212.0 X 0.0690 X 30.8 = 450 R-21 Wall (SE) 192.0 X 0.0690 X 28.8 = 381 R-21 Wall (SIM 237.0 X 0.0690 x 31.9 = 521 R-21 Wall (NW) 535.0 X 0.0690 x 29.0 = 1,071 X X = x x x x = x x Page Total 3,618 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 1 (NE) 0.0 X 19.2 + 8.0 X 33.8 = 271 Window 2 (SE) 0.0 X 19.2 + 4.0 X 23.5 = 94 Window 3 (SW) 0.0 X 19.2 + 120.0 X 28.0 = 3,355 Window 4 (SW) 0.0 X 19.2 + 3.0 X 28.0 = 84 Window 5 (NM 0.0 X 19.2 + 9.0 X 29.9 = 269 Window 6 (NW) 0.0 X 19.2 + 9.0 X 29.9 = 269 Window 7 (NW) 0.0 X 19.2 + 9.0 X 29.9 = 269 Window 8 (NW) 0.0 X 19.2 + 4.0 X 29.9 = 119 X + X = Page Total 4,729 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,60o Btu = 0 Infiltration: 1.064 X 1.16 X 54.50 x 34 = 2,292 Alr Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,069 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 54.50 X 0.00276 = 835 Air Sensible CFM ELA ❑W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,035 �FneivvPro 5.1 by EneMvsoft User Number: 6712 Run Code: 20-02-20T1T:10:35 la: Pa a 37 of 46.1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room/Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1,942.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces R 38 Roof Attic R-21 Wall R 21 Wall R-21 Wall Wood door R 21 Wall Orientation (NE) (NE) (SE) (SK9 (SW) (NIA9 Area X X X X X X X x x U-Factor X X X X X X x x x CLTD' = = = = = = = = = 820.0 0.0250 56.0 382.0 0.0690 30.8 303.5 0.0690 28.8 722.4 0.0690 31.9 20.6 1.4500 31.9 289.0 0.0690 29.0 Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanpstratinn Window 9 Wndow 10 Window 11 Window 12 Ohndow 13 Window 14 Window 15 Window 16 Window 17 Orientation (NE) (NE) (NE) (NE) (SE) (SE) (SW) (SW) (SW) Area X X X x X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 6.2 19.2 1.8 33.8 42.9 19.2 2.1 33.8 54.0 19.2 0.0 33.8 0.0 19.2 45.0 33.8 0.0 19.2 22.5 23.5 0.0 19.2 4.0 2a5 0.0 19.2 120.0 28.0 0.0 19.2 290.0 28.0 0.01 19.2 10.01 28.0 Page Total Btu/hr 1,148 811 603 1,590 953 578 Btu/hr 181 897 1.039 1,523 529 94 3,355 8,107 280 Internal Gain Btu/hr Occupants 2•0 Occupants X 230 Btuh/occ. Equipment 11.0 Dwelling Unit X 1,600Btu = 1 Infiltration: 1.064 X 1.16 X 106.27 X 34 = C Air Sensible CFM EL+ AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,837 Latent Gain Btu/hr flcCu ants 2•0 Occupants X 200 Btuh/occ. - 400 Infiltration: 4,771 X 1.16 X 106.27 X 0.00276 = 1,628 Air Sensible CFM ELA .7W DOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2 028 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 1 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room/Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1,942.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF O a ue Surfaces Orientation Area U-Factor CLTD' Btu/hr x x = x x = x x = x x = x x = x x = x x = x x = x x = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. t. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 18 (SM 0.0 X 19.2 + 48.0 X 28.0 = 1,342 Window 19 (Sly 0.0 X 19.2 + 10.0 X 28.0 = 280 X + X = X + X = X + X = X + X = X + X = X + X = X + I X = Page Total 1,621 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. _ 460 Eclulpment 1.0 Dwelling Unit X 1,600 Btu _ 1,600 Infiltration: 1.064 X 1.16 X 106.27 x 4,469 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,637 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 X 1.16 X 106.27 X 0.00276 = 1,628 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,028 Ens Pro 5.1 by EnemvSoff User Number: 6712 Ru Cod : 2013.42.20T17:1 .35 ID Page 39 of 46 ESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom #2 & 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 939.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic (NE) 80.0 x 0.0250 X 56.0 = 112 R-21 Wall (NE) 250.0 X 0.0690 X 30.8 = 531 R-21 Wall (SE) 313.0 X 0.0690 X 28.8 = 622 R-21 Wall (SIM 123.0 X 0.0690 x 31.9 = 271 R 21 Wall (NW) 172.0 X 0,0690 X 29.0 = 344 x X = X x = x x = x x = E1,879 Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr MAdow 20 (SE) 0.0 X 19.2 + 48.0 X 23.5 = 1.128 Window 21 (SE) 0.0 X 19.2 + 8.0 X 23.5 = 188 Window 22 (SE) 0.0 X 19.2 + 8.0 X 23.5 = 186 Window 23 (SE) 0.0 X 19.2 + 48.0 X 23.5 = 1,128 Window 24 (NW) 0.0 X 19.2 + 20.0 X 29.9 = 597 Window 25 (NW) 0.0 X 19.2 + 40.0 X 29.9 = 1,194 Window 26 (NW) 0.0 X 19.2 + 20.0 X 29.9 = 597 Wrndow 27 (NW) 0.0 X 19.2 + 48.0 X 29.9 = 1,433 x + x = Page Total s,454 Internal Gain Btu/hr- Occupants 2•0 Occupants X 230 Btuh/occ. = 460 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 x 1.16 x 51.38 x 31 2,181 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,954 Latent Gain Btu/hr Occu 2•0 Occupants x 200 Btuh/acc. = 400 ants Infiltration: 4,771 x 1.16 x 51.38 x 0.00276 = 787 AirSenslble CFM ESA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 187 Erie Pro 5.1 by EnerqvSoft User Number., 6712 RunCode: 201-02-20717:10.35 ID: Pa a 40 of 413 'ESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 1 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Gym Outdoor Dry Bulb Temperature 112 OF Floor Area 375.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orlentation Area U-Factor CLTD' Btu/hr R-38 Roof Attic (NE) 75.0 X 0.0250 X 56.0 = 105 R-21 Wall (NE) 129.5 X 0.0690 X 30.8 = 275 R-21 Wall (SE) 73.01 X 0.0690 X 28.8 = 145 R-21 Wall (SlM 131.4, X 0.0690 X 31.9 = 289 R-21 Wall (NtM 327.0 X 0.0690 X 29.0 = 654 X X = X X = X X = X X = Page Total 1,466 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 28 (NE) 0.0 X 19.2 + 16.5 X 33.8 = 559 Window 29 (SE) 0.0 X 19.2 + 8.0 X 23.5 = 188 Window 30 (SW) 0.0 X 19.2 + 12.6 X 28.0 = 358 Window 31 (SlM 0.0 X 19.2 + 40.0 X 28.0 = 1,118 Window 32 (SlM 0.0 X 19.2 + 12.8 X 28.0 = 358 X + X = X + X = X + X = X + X = Page Total 2,580 Internal Gain Btu/hr Occu ants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1.600 Btu = 0 Infiltration: 1.064 X 1.16 X 20.52 X 34 = 863 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4.912 Latent Gain Btu/hr Occupants 0.o Occupants X 200. Btuh/occ. = 0 Infiltration: 4,771 X 1.16 X 20.52 X 0.00276 = 314 Air Sensible CFM ELA ❑W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 314 EnercvPra 5.1 by EnemySoft User Number: 6712 RunCode: 2 1-02-20T17:?4:35 10-- Page 41 of 48 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 1 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage Outdoor Dry Bulb Temperature 112 OF Floor Area 299.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-36 Roof Attic (NE) 39.0 X 0.0250 X 56.0 = 55 R-21 Wall (NE) 130.0 x 0.0690 X 30.8 = 276 R-21 Wall (SE) 214.0 X 0.0690 X 28.8 = 425 R-21 Wall (Sl9 65.6 x 0.0690 X 31.9 = 144 x x = x x = X x = x x = x x = Page Total 900 Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 33 (SE) 0.0 X 19.2 + 8.0 X 23.5 = 188 Wrndow 34 (SE) 0.0 X 19.2 + 8.0 X 23.5 = 188 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 376 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 16.36 X 34 = 688 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 1,964 Latent Gain Btu/hr Occupants 0 Occupants X 200 Btuh/occ. = o Infiltration: 4,771 X 1.16 X 16.36 X 0.00276 251 AirSenslble CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 251 EnemvPro 5.1 by EneravSoft user Number- 6712 RunCode: 2013-02-20T17:10:35 0: Pa a 42 of 46 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Berdroom 1 Outdoor Dry Bulb Temperature 112 OF Floor Area 547.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic (NE) 547.0 X 0.0250 X 56.0 = 766 R-21 Wall (NE) 210.0 X 0.0690 X 30.8 = 446 R-21 Wall (SE) 227.4 X 0.0690 X 28.8 = 452 R-21 Wall (SW) 204.41 X 0.0690 X 31.9 = 450 R-21 Wall (NW) 246.0 X 0.0690 X 29.0 = 492 X X = X X = X X = X X = Page Total 2,605 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window35 (NE) 0.0 X 19.2 + 40.0 X 33.8 = 1,354 Window 36 (SE) 0.0 X 19.2 + 11.3 X 23.5 = 266 Window 37 (SE) 0.0 X 19.2 + 11.3 X 23.5 = 266 Window 38 (SlM 0.0 X 19.2 + 12.8 X 28.0 = 358 Window 39 (SW) 0.01 X 19.2 + 20.0 X 28.0 = 559 Window 40 (SW) 0.0 X 19.2 + 12.8 X 28.0 = 358 Window 41 (NM 0.0 X 19.2 + 4.0 X 29.9 = 119 X + X = X + X = Page Total 3,279 Internal Gain Btu/hr Cccu ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 29.93 X 34 = 1,259 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7.373 Latent Gain Btu/hr 1.0 Occupants X 200 Btuh/occ. 200 Occupants Infiltration: 4,771 X F 1.16 X 29.93 X 0.00276 = 458 Alr Sensible CFM ESA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 658 Ene Pro .1 by Ene Sot? User Numher. 6712 RunCode: 2013-02-20717:10:35 11): Page 43 ot46 'FEE IDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 465.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic (NE) 465.0 X 0.0250 X 56.0 = 651 R-21 Wall (NE) 199.0 x 0.0690 X 30.8 = 423 R-21 Wall (SE) 351.0 X 0.0690 x 28.8 = 697 R-21 Wall (SW) 195.0 X 0.0690 X 31.9 = 429 R-21 Wall (NW) 355.0 X 0.0690 X 29.0 = 710 R-19 Floor Crawlspace 81.0 x 0.0460 X 19.0 = 71 x x = x x = x x = Page Total Z981 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 42 (NE) 0.0 X 19.2 + 18.0 X 33.8 = 609 Window 43 (NE) 0.0 X 19.2 + 18.0 X 33.8 = 609 Window 44 (SE) 0.0 X 19.2 + 24.0 X1 23.5 = 564 Window 45 (SW) 0.0 X 19.2 + 40.0. X 28.0 = 1,118 Window 46 (NK9 0.0 X 19.2 + 10.0 X 29.9 = 299 Window 47 (NM 0.0 x 19.2 + 10.0 X 29.9 = 299 X + X = X + X = X +1 X = Page Total 3,498 Internal Gain Btu/hr X Occupants 1.0 Occupants 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 x 1.16 x 25.44 x 34 = 1,070 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7.779 Latent Gain Btu/hr Occupants 1•0 Occupants X 200 J Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 25.44 X 0.00276 = 390 Air Sensible CFM EL4 AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 590 Ene Pro 5.1 by EnamvSoft User Number: 6712 R nCode: 2013.02.20T17:10. fD: Page 44 of46 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC I 212012013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,831.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic (NE) 1,831.01 X 0.0250 X 56.0 = 2, 563 R-21 Wall (NE) 486.0 X 0.0690 X 30.8 = 1,032 R-21 Wall (SE) 438.0 X 0.0690 X 28.8 = 870 R-21 Wall (SW) 124.0 X 0.0690 X 31.9 = 273 R-21 Wall (NV4 440.0 X 0.0690 X 29.0 = 860 X X = X X = X X = X X = Page Total 5,619 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 48 (NE) 0.0 X 192 + 24.0 X 33.8 = 812 Window 49 (NE) 0.0 X 19.2 + 48.0 X 33.6 = 1.625 Window 50 (NE) 0.0 X 19.2 + 24.0 X 33.8 = 812 Window 51 (NE) 0.0 X 19.2 + 32.0 X 33.8 = 1,083 Window 52 (NE) 0.0 X 19.2 + 8.0 X 33.8 = 271 Window 53 (NE) 0.0 X 19.2 + 8.0 X 33.8 = 271 Window 54 (SE) 0.0 X 19.2 + 4.0 X 23.5 = 94 Window 55 (SE) 0.0 X 19.2 + 4.0 X 23.5 = 94 Window 56 (SE) 0.01 X 1 19.2 + 42.0 X 1 23.5 = 967 Page Total s,o49 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X X 34 = 4,214 Air Sensible Et1e00.19 CFM �T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,145 Latent Gain Btu/hr 1.o Occupants X 2001, Btuh/occ. = 200 Occupants Infiltration: 4,771 X 1.16 X 100.19 X 0.00276 = 1,535 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,735 EherovPro 5.112y EneravSoft Vwr Number: 6712 RunCode: 2013.02-20T17:10:35 ID-- Pacie 45 of 46 � r=!91DENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence for Desert Ring, LLC 2/20/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,831.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor X X CLTD' = Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window 57 (SE) 0.0 X 19.2 + 16.0 X 23.5 = 376 Window 58 (SE) 0.0 X 19.2 + 16.0 X 23.5 = 376 Window 59 (SW) 0.0 X 19.2 + 96.0 X 28.0 = 2,684 Window 60 (NVIO 0.0 X 19.2 + 10.0 X 29.9 = 299 Window 61 (NIAO 0.0 X 19.2 + 10.0 X 29.9 = 299 X + X - X + X - X + X - X + X - Page Total 4,033 Internal Gain Btulhr Occupants 1.0 Occupants X 230 Btuh/occ. _ 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 100.19 X 34 = 4.214 Alr 5enslble CFM EI.A AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,145 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 100.19 X 0 00276 = f 1.5.35 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.735 EneruvPro 5.1 by EnemvSoff User Number 6712 RunCode: 2013-02-20T17:10:35 ID: Pace 46 of 46