BWFE2015-0038 Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: R.W. Real Estate Avenida Carranza La Quinta, CA Project Designer: 11 Report Prepared by: Joan D. Hacker Insu-form, Inc. 77810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 Cisme OF LA BUILPIrING & SAFE-P(D p� APPROVED FOR CONSTRUCTION DATE%Z��BY �_ Job Number: Date: RECEIVED SEP 1 12014 9/9/2014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT, The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft,' LLC — www.energysoft.com. User TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary EnergyPro 6.3 by EnergySoft Job Number: ID: User Number: 2655 1 2 3 13 16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CFI R -PRF -01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Single Family Residence 02 Calculation Description Title 24 Analysis 03 Project Location Avenida Obregon 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3 (650) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FTZ) 1992 15 Number of Zones 1 16 Slab Area (FTZ) 1992 17� Number of Stories 1 18 Addition Cond. Floor Area NA ®AS's Natural Gas Available Yes 20 Addition Slab Area (FTZ) NA Glazing Percentage (%)'15.4% e+o COMPLIANCE RESULTS _® 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown belo U1LD1 OF OUN- �G & SAFETY � � AP '���T. FOR ONS7-{gVED UCT1ON _ ABY I P AV Registration Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 2 of 10 Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 3.70 4.33 -0.63 -17.0% Space Cooling 104.49 105.74 -1.25 -1.2% IAQ Ventilation 1.12 1.12 0.00 0.0% Water Heating 12.58 10.49 2.09 16.6% PV Credit - 0.00 0.00 - North Facing Compliance Total 121.89 121.68 0.21 0.2% Space Heating 3.70 .50 -0.80 -21.6% Space Cooling 104.49002.93 1.56 1.5% IAQ Ventilation 1.12 1.12 0.00 0.0% Water Heating 12.58 0 10.49 2.09 16.6% PV Credit - a 0.00 0.00 - East Facing Compliance Total 121.89 119.04 2.85 2.3% Space Heating 3.70 3.85 -0.15 -4.1% Space Cooling 104.49 ® 102.67 1.82 1.7% IAQ Ventilation 1.12 1.12 0.00 0.0% Water Heating 12.58 a�� 10.49 2.09 16.6% PV Credit - 0.00 0.00 - South Facing Compliance Total 121.89 118.13 3.76 3.1% Space Heating 3.fW 3.74 -0.04 -1.1% Space Cooling 1A09' 101.81 2.68 2.6% IAQ Ventilation 4.12 1.12 0.00 0.0% Water Heating 12.58 10.49 2.09 16.6% PV Credit 0 - 0.00 0.00 - West Facing Compliance Total. Q 121.89. 117.16 4.73 • 3.9% Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) Front Wall Whole House R-21 Wall 270 Right 1000 171.999 90 Left Wall Whole House R-21 Wall 0 Front 1000 40 90 Rear Wall Whole House R-21 Wall 90 Left 1000 28.4976 90 Right Wall Whole House R-21 Wall 180 Back 1000 65.5056 90 Roof Whole House R-38 Roof Attic 1992 ATTIC 01 02 03 b4 05 06 - 07 Name Construction Roof Rise R f'Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 0 0.1 0.85 Yes No e ®-N e Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation DatelTime: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft ) Height (ft) Multiplier Area (1`1:2) U -factor SHGC Exterior Shading Window Window Front Wall (Right -270) 4.9 10.0 0.837 41.0 0.40 0.30 Window 2 Window Front Wall (Right -270) 6.0 10.0 1 60.0 0.40 0.30 Window 3 Window Front Wall (Right -270) 4.5 10.0 0.911 4.1.0 0.40 0.30 Window Window Front Wall (Right -270) 3.9 10.0 0.769 30.0 0.40 0.30 Window 5 Window Left Wall (Front -0) 4.0 5.0 1 20.0 0.40 0.30 Window Window Left Wall (Front -0) 4.0 g ijw5.0 1 20.0 0.40 0.30 Window 7 Window Rear Wall (Left -90) 4.� 1.5 1 6.0 0.40 0.30 Window 8 Window Rear Wall (Left -90) .09 0? 1.2 0.972 10.5 0.40 0.30 Window 9 Window Rear Wall (Left -90) .0 1.5 1 6.0 0.40 0.30 Window 10 Window Rear Wall (Left -90) 4.0 1.5 1 6.0 0.40 0.30 Window 11 Window Right Wall (Back -180) 1.9 9.0 0.936 16.0 0.40 0.30 Window 12 Window Right Wall (Back -180) 3.0 8.0 1 24.0 0.40 0.30 Window 13 Window Right Wall (Back -180) 3.0 1.0 1 3.0 0.40 0.30 Window 14 Window Right Wall (Back -180) oa� 5.0 1.5 1 7.5 0.40 0.30 Window 15 Window Right Wall (Back -180) 5.0 1.5 1 7.5 0.40 0.30 Window 16 Window Right Wall (Back -1 8Or4 5.0 1.5 1 7.5 0.40 0.30 Registration Number: CA Building Energy Efficiency Stanch ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CFI R -PRF -01 Page 6 of 10 OVERHANGS AND FINS 01 02 03 04 05 06 Construction Name Surface Type Type Framing Total Cavity R -value Assembly Layers 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Roof Truss @ 24 in. Roof Deck: Wood Siding/sheathing/decking Overhang Attic Roofs Wood Framed Ceiling O.C. Left Fin Roofing: Light Roof (Asphalt Shingle) .IV• vlki Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up Window 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 4 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 Window 11 16 0.1 16 16 �`v0 0 0 0 0 0 0 0 0 Window 12 16 0.1 16 16 < 0 0 0 0 0 0 0 0 0 Window 13 16 0.1 16 16,,.0 0 0 0 0 0 0 0 0 0 Window 14 2 0.1 2 0 0 0 0 0 0 0 0 0 Window 15 2 0.1 2 0 0 0 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 zl%lr OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Type Framing Total Cavity R -value Assembly Layers Construction 2x4 Top Chord of Cavity /Frame: no insul. / 2x4 Top Chrd Roof Truss @ 24 in. Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) .IV• vlki Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall Exterior Walls' Wood Framed Wall 2x6 @ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking Inside Finish: Gypsum Board 0 Cavity / Frame. R-9.1 / 2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Over Floor Joists: R-28.9 insul. NA AV Registration Number: ot t4 CA Building Energy Efficiency Stan bids - 2013 Residential Compliance Registration Date/Time: Report Version - CFiR-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CFI R -PRF -01 Page 7of10 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Slab -on -Grade Whole House 1992 16 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — t9 WATER HEATING SYSTEMS A 01 02 �_ 03 04 Name Distribution Type �'r Number of Heaters Solar Fraction (°k) DHW Sys 1 Pipe Insulation, All Lines ��� 1 0.0% 01 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type P� Tank Type a®vim Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage, 50 0.65 43000-Btu/hr 0 0 Aw0" WATER HEATING - HERS VERIFICATION s 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a Na n/a n/a n/a _R HVAC SYSTEMS ,PA,. 01 02 �� 03 04 05 06 07 �. e �r Heating System Cooling System % Distribution Floor Area Name Syy"tem Type Name Ducted Name Ducted System Fan System Served Whole House1 Other Heat ng and Cooling System Heating Component 1 Yes Cooling Yes Air Distribution HVAC Fan 1 1992 R Component 1 System 1 .0 Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE CF1 R -PRF -01 Page 8of10 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEE Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond -Split air conditioning 12.5 1. No No Cooling Component Not Required Not Required system 1 -hers -cool L 7u HVAC COOLING - HERS VERIFICATION Ao 01 02 03 04 05 06 Name Verified Airflow xv Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 35,0 Required Required Required N HVAC - DISTRIBUTION SYSTEMS J2 01 02 03 04 05 06 07 08 Name Type Duct Leak age-"�� Insulation R -value Supply Duct Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Specified L�e� Leakage get 8 Attic Attic None Air Distribution System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 010 01 02 f" 1%"W 03 04 05 06 61 Verified Duct Design Name Duct Leakage VerificA�tt',on Duct Leakage Target (°k) Verified Duct Location Return Supply Air Distribution System 1 -hers -dist Required 1 6.0 Not Required Not Required Not Required HVAC -FAN SYSTEMS 01 02 03 04 Name g'/ Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1` Single Speed PSC Furnace Fan 0.58 Required Registration Number:,�� Registration Date/Time: CA Building Energy Efficiency Standa ds - 2013 Residential Compliance Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 9of10 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 49.92 0.25 AWDefault 0 Required 14PRegistration Number: CA Building Energy Efficiency Stand`afds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CFI R -PRF -01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Aut or Signature: Joan D. Hacker Company: Signature Date: Insu-form, Inc. 9/9/2014 Address: CEA/HERS Certification Identification (If applicable): 77810 Las Montanas Road, Suite 201 City/Stat ip: Falco Desert, Ca 92211 Phone: 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: o�� 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility %tee building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this CertificateCompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency��for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Company: �y, ` Date Signed: Address: �� License: City/State/Zip: Q 1 Phone: 0 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-09042014-650 HERS Provider: Report Generated at: 2014-09-09 13:58:56 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 WAR Project Name Date R.W. Real Estate 191912014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown, elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets therequirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor. 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 24orequivalent U -factor. *§1 50.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 ern -/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is reater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous buming pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number: 2655 /D: Page 13 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date R.W. Real Estate 191912014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.06)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §150.06)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0(m)10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components : A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.0 : Residential pool systems orequipment meet the pump sizing,flow rate piping,filters and valve requirements of §150.0(p). Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B as applicable. 150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lams rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number: 2655 ID: Page 14 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date R. W. Real Estate 1911912014 150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ftz may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below, and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9 130.0 130.2 130.4 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4 140.6 and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.3 by EnergySoft User Number: 2655 ID: Page 15 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name R.W. Real Estate Date 9/9/2014 System Name Whole House Floor Area 1,992 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,029 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 70,000 24,524 2,073 648 23,781 Total Output Btuh 70,000 0 Output Btuh/ ft 35.1 1,416 1,169 Cooling System 01 0 Output per System 58,000 0 0 0 0 Total Output Btuh 58,000 0 2,073 0 Total Output ons 4.8 1,416 1,169 Total Output Btuh/s ft 29.1 Total Output s ft/Ton 412.1 27,355 26,118 Air System CFM per System 2,210 HVAC EQUIPMENT SELECTION Airflow ctm 2,210 BDP CO. 561AJ060-" 43,872 5,839 70,000 Airflow cfm/s ft 1.11 70,000 Jan 1 AM Airflow cfm/Ton 457.2 Outside Air °/6 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 43,872 5,839 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF O Outside Air 0 cfm Supply Fan 2,210 cfm 70 OF 70 OF 105 OF Heating Coil _ 105 OF 'ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/63°F 79/63°F 55/54°F • Outside Air 0cfm Supply Fan Cooling Coil 2,210 cfm 79/63 OF 1 CITY OF IA QUINTA4 OF BUILDING & SAFETY DE AP OR FOR CONSTRUCTION7t3/s3 F DATE BY Energ Pro 6.3 by Ener Soft User Number: 2655 RunCode: 2014-09-09T14:00:35 /D: Pae 16 of 16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Datefrime: 15:03, Tue, Nov 25, 2014 Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 1 of 9 GENERAL INFORMATION 01 Project Name Single Family Residence 02 Calculation Description Title 24 Analysis 03 This building Incorporates one or more Special Features shown below 03 Project Location 54640 Avenida Carranza, 54310 Avenida Obregon 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1992 15 Number of Zones 1 16 Slab Area (FT2) 1992 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) N/A 21 Glazing Percentage (°k) 15.4% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building Incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building Incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use Standard (kTDV/ft) Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.70 4.33 -0.63 -17.0% Space Cooling 104.49 105.74 -1.25 -1.2% IAO Ventilation 1.12 1.12CITY :0'0 0.0% Water Heating 12.58 10.49?T- RAFT1 nPPT I 16.6% Photovoltaic Offset ---- 0.00 D17r0 % /I` Q — Compliance Energy Total 121.89 121.68O Q�. 1 `T T RLjr 0.2% EO tel 14.Yk Registration Number: 214-No147237A-000000000-0000 Registration Date/Time: 2014-12.02 22:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 '- s �nfr�'..�3+� a ,,)�. r.+�i�i �t ► i ' i fIt In }rr 141.2 t ,.i aL t f + i t ily Ir I rr C1 r� •' I 1 ,+ ,r `' ' ?; t :I � e: .". � r �? � � � , j •c } n } :' it j f ( ! { � ili } t rl , r � s•': ! � � n: 1 ,-. 1 _.. s (t + (.. «Y � 4 1 i j 1 � , 1 i T 4l l {ir �_ is p i rr I Mwt. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Datelrime: 15:03, Tue, Nov 25, 2014 Input File Name: RW Real Estate Residence.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of Insulation • Window overhangs and/or fins HERS FEATURE SUMMARY CF1 R -PRF -01 Page 2 of 9 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: IAQ mechanical ventilation Cooling System Verifications: • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • —None — ' «�, '7 r. �..: a ,wr •. -. /! .. ,-w p 7�"�ry ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach forthe Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating MarginPercent Improvement Total Energy (kTDV/f2)• 169.72 169.51 0.21 0.1% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Family Residence 1992 1 3 1 0 1 Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation DaterrIme: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 3 of 9 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned Whole Houses 1992 11 DHW Sys 1 Gross Area (ft2) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tllt(deg) Front Wall Whole House R-21 Wall 270 Left 1000 171.999 90 Left Wall Whole House R-21 Wall 0 Back 1000 40 90 Rear Wall Whole House R-21 Wall 90 Right 1000 28.4976 90 Right Wall Whole House R-21 Wall 180 Front 1000 65.5056 90 Roof Whole House R-38 Roof Attic 1992 ATTIC > 1 01 02 t 03;. _ �i 04 ` 05 06 07 Name t Construction �� , Roof Rise- Roof Reflectance.` Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons . 0 0.1 0.85 Yes No Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance. Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (W) 1.1 -factor SHGC Exterior Shading Window Window Front Wall (Left -270) 4.9 10.0 0.837 41.0 0.40 0.30 Insect Screen (default) Window 2 Window Front Wall (Left -270) 6.0 10.0 1 60.0 0.40 0.30 Insect Screen (default) Window 3 Window Front Wall (Left -270) 4.5 10.0 0.911 41.0 0.40 0.30 Insect Screen (default) Window 4 Window Front Wall (Left -270) 3.9 10.0 0.769 30.0 0.40 0.30 Insect Screen (default) Window 5 Window Left Wall (Back -0) 4.0 5.0 1 20.0 0.40 0.30 Insect Screen (default) Window 6 Window Left Wall (Back -0) 4.0 5.0 1 20.0 0.40 0.30 Insect Screen (default) Window 7 Window Rear Wall (Right -90) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 8 Window Rear Wall (Right -90) 9.0 1.2 0.972 10.5 0.40 0.30 Insect Screen (default) Window 9 Window Rear Wall (Right -90) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 10 Window Rear Wall (Right -90) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 11 Window Right Wall a(Fro.nt-180) 1.9- _ _9.0 0.936 16.0 0.40 0.30 Insect Screen (default) Window 12 Window r Right-VVall (Front -180) 3.0. `` 8.0%;_ 1 24.0 0.40 0.30 Insect Screen (default) Window 13 Windowght Wall (Front7180) ' r 3.0 1".0 1 3.0 0.40 0.30 Insect Screen (default) Window 14 Window ' / 1 '' Right Wall (Front -180) 5.0*.,.." ;1:5 ' ,k 1, :_ , 7.5 0.40 0.30 Insect Screen (default) Window 15 Window Flight Wall (Front -180) 5.0 1.5 1 7.5 0.40 0.30 Insect Screen (default) Window 16 Window Right Wall (Front -1 80)5.0 1.5 1 7.5 0.40 0.30 Insect Screen (default) Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Datefrime: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 01 02 03 04 05 06 07 O6 09 10 11 12 13 14 O.C. none - Roofing: Light Roof (Asphalt Shingle) Overhang Left Fin - Inside Finish: Gypsum Board Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DIstL Bot Up Depth Top Up Dist R Bot Up Window 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 4 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2- 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 11 , "16:. 0.1) 16 i 16 ... ,. 10' ', 0 : " , 0 0 0 0 0 0 0 Window 12 16 ° 0.1.1 16 16 ,. a 0 0 0 0 0 0 0 0 0 Window 13 16,4/ 0.1 i 160 , 16' 0 01, 0. 0 0 0 0 0 0 Window 14 2 0.1-: 2 2 0 0 0 0 0 0 0 0 0 Window 15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 2x4 Top Chord of - Cavity/Frame: no insul. /2x4 Top Chrd Roof Truss @ 24 in. - Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none - Roofing: Light Roof (Asphalt Shingle) - Inside Finish: Gypsum Board - Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 - Exterior Finish: Wood Siding/sheathing/decking - Inside Finish: Gypsum Board - Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 - Over Floor Joists: R-28.9 insul. Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 -Page 6 of 9 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Slab -on -Grade Whole House 1992 16 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% WATER HEATERS t - 01 02 ' �' 03 1 04 ' 05 06 07 08 Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 Tank Exterior WA WA - ' N/A Tank Volume Energy Factor or- Other Heat/Cool Insulation Standby Loss Name Heater Element Type Tank Type (gal) Efficiency Input Rating R -value (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.65 43000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 WA WA WA N/A N/A WA HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served Whole Housel Other Heat/Cool Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 1992 Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Datefrime: 15:03, Tue, Nov 25, 2014 Input File Name: RW Real Estate Residence.xml HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE CF1 R -PRF -01 Page 7 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name }., Verified Airflow Efficiency Verified EER Muld-speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 12.5 15 No No Cooling Component Ducts located in attic system 8 Attic Attic None 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name }., Verified Airflow ,-, Air(Iow,Targetr__ _ Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool 'i- Requiredi. + i 350 ] =Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04` 05 06 07 08 Verified Duct Design Low -leakage Supply Duct Verification Duct Leakage Target (%) Verified Duct Location Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Specified Lower 8 Attic Attic None Air Distribution Leakage Target System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 Duct Leakage Verified Duct Design Low -leakage Name Verification Duct Leakage Target (%) Verified Duct Location Return Supply Air Handler Air Distribution System Required 6.0 Not Required Not Required Not Required Required 1 -hers -dist Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Datefrime: 15:03, Tue, Nov 25, 2014 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml CF1 R -PRF -01 Page 8 of 9 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAO (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAO Watts/CFM [AQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 49.92 0.25 Default 0 Required Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Page 9 of 9 Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: 7� Joan Hacker ta J"un c!-cr7er Company: Signature Date: Joan Hacker 2014-12-02 09:01:47 Address: CEA/HERS Certification Identification (If applicable): 77810 Las Montanas Road, Suite 201 City/State/Zip: Phone: Palm Desert, CA 92211 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified ornthis Certificate ofCompliance are consistent. with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this.building permit application. Responsible Designer Name: i ? Responsible DesignerSignature:. Gabriel Rios o Company: Date Signed: Rios Designs 2014-12-02 22:39:25 Address: License: 49-901 Cinnabar Lane na City/State/Zip: Phone: Coachella, CA 92236 760-485-7431 CITY OF LA QUINT -A BUILDING�y�&�SAAFET�—Y�DEPT. Digitally signed by CaICERTS. This digital signature is provided in order to secure PEonte"nt'of°thi r stpr�'d docum nt and in noway implies Registration Provider responsibility for the accuracy of the IV CONSTRUCTION information. [DATE_. BY Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26