BWFE2015-0038 Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:
R.W. Real Estate
Avenida Carranza
La Quinta, CA
Project Designer:
11
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
Cisme OF LA
BUILPIrING & SAFE-P(D p�
APPROVED
FOR CONSTRUCTION
DATE%Z��BY �_
Job Number:
Date:
RECEIVED
SEP 1 12014
9/9/2014 CITY OF LA QUINTA
COMMUNITY DEVELOPMENT,
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft,' LLC — www.energysoft.com.
User
TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
EnergyPro 6.3 by EnergySoft Job Number: ID: User Number: 2655
1
2
3
13
16
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CFI R -PRF -01
Page 1 of 10
GENERAL INFORMATION
01
Project Name Single Family Residence
02
Calculation Description Title 24 Analysis
03
Project Location Avenida Obregon
04
A City La Quinta
05
Standards Version Compliance 2014
06
Zip code
07
Compliance Manager Version BEMCmpMgr 2013-3 (650)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.3
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) Cardinal
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FTZ) 1992
15
Number of Zones 1
16
Slab Area (FTZ) 1992
17�
Number of Stories 1
18
Addition Cond. Floor Area NA
®AS's
Natural Gas Available Yes
20
Addition Slab Area (FTZ) NA
Glazing Percentage (%)'15.4%
e+o
COMPLIANCE RESULTS _®
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown belo
U1LD1 OF OUN-
�G & SAFETY � �
AP '���T.
FOR ONS7-{gVED
UCT1ON
_ ABY I
P
AV
Registration
Registration Number:
CA Building Energy Efficiency Stands - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 2 of 10
Registration Number:
CA Building Energy Efficiency Stands - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
3.70
4.33
-0.63
-17.0%
Space Cooling
104.49
105.74
-1.25
-1.2%
IAQ Ventilation
1.12
1.12
0.00
0.0%
Water Heating
12.58
10.49
2.09
16.6%
PV Credit
-
0.00
0.00
-
North Facing Compliance Total
121.89
121.68
0.21
0.2%
Space Heating
3.70
.50
-0.80
-21.6%
Space Cooling
104.49002.93
1.56
1.5%
IAQ Ventilation
1.12
1.12
0.00
0.0%
Water Heating
12.58
0 10.49
2.09
16.6%
PV Credit
-
a 0.00
0.00
-
East Facing Compliance Total
121.89
119.04
2.85
2.3%
Space Heating
3.70
3.85
-0.15
-4.1%
Space Cooling
104.49
® 102.67
1.82
1.7%
IAQ Ventilation
1.12
1.12
0.00
0.0%
Water Heating
12.58
a�� 10.49
2.09
16.6%
PV Credit
- 0.00
0.00
-
South Facing Compliance Total
121.89
118.13
3.76
3.1%
Space Heating
3.fW
3.74
-0.04
-1.1%
Space Cooling
1A09'
101.81
2.68
2.6%
IAQ Ventilation
4.12
1.12
0.00
0.0%
Water Heating
12.58
10.49
2.09
16.6%
PV Credit
0 -
0.00
0.00
-
West Facing Compliance Total.
Q 121.89.
117.16
4.73 •
3.9%
Registration Number:
CA Building Energy Efficiency Stands - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tilt(deg)
Front Wall
Whole House
R-21 Wall
270
Right
1000
171.999
90
Left Wall
Whole House
R-21 Wall
0
Front
1000
40
90
Rear Wall
Whole House
R-21 Wall
90
Left
1000
28.4976
90
Right Wall
Whole House
R-21 Wall
180
Back
1000
65.5056
90
Roof
Whole House
R-38 Roof Attic
1992
ATTIC
01 02 03 b4 05 06 - 07
Name Construction Roof Rise R f'Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Attic Roof Cons 0 0.1 0.85 Yes No
e
®-N
e
Registration Number:
CA Building Energy Efficiency Stands - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation DatelTime: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 5 of 10
WINDOWS
01
02
03
04
05
06
07
08
09 10
Name
Type
Surface (Orientation -Azimuth)
Width(ft
)
Height
(ft)
Multiplier
Area
(1`1:2)
U -factor
SHGC Exterior Shading
Window
Window
Front Wall (Right -270)
4.9
10.0
0.837
41.0
0.40
0.30
Window 2
Window
Front Wall (Right -270)
6.0
10.0
1
60.0
0.40
0.30
Window 3
Window
Front Wall (Right -270)
4.5
10.0
0.911
4.1.0
0.40
0.30
Window
Window
Front Wall (Right -270)
3.9
10.0
0.769
30.0
0.40
0.30
Window 5
Window
Left Wall (Front -0)
4.0
5.0
1
20.0
0.40
0.30
Window
Window
Left Wall (Front -0)
4.0 g ijw5.0
1
20.0
0.40
0.30
Window 7
Window
Rear Wall (Left -90)
4.�
1.5
1
6.0
0.40
0.30
Window 8
Window
Rear Wall (Left -90)
.09 0?
1.2
0.972
10.5
0.40
0.30
Window 9
Window
Rear Wall (Left -90)
.0
1.5
1
6.0
0.40
0.30
Window 10
Window
Rear Wall (Left -90)
4.0
1.5
1
6.0
0.40
0.30
Window 11
Window
Right Wall (Back -180)
1.9
9.0
0.936
16.0
0.40
0.30
Window 12
Window
Right Wall (Back -180)
3.0
8.0
1
24.0
0.40
0.30
Window 13
Window
Right Wall (Back -180)
3.0
1.0
1
3.0
0.40
0.30
Window 14
Window
Right Wall (Back -180) oa�
5.0
1.5
1
7.5
0.40
0.30
Window 15
Window
Right Wall (Back -180)
5.0
1.5
1
7.5
0.40
0.30
Window 16
Window
Right Wall (Back -1 8Or4
5.0
1.5
1
7.5
0.40
0.30
Registration Number:
CA Building Energy Efficiency Stanch ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CFI R -PRF -01
Page 6 of 10
OVERHANGS AND FINS
01
02
03
04
05
06
Construction Name
Surface Type
Type
Framing
Total Cavity R -value
Assembly Layers
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Roof Truss @ 24 in.
Roof Deck: Wood Siding/sheathing/decking
Overhang
Attic Roofs
Wood Framed Ceiling
O.C.
Left Fin
Roofing: Light Roof (Asphalt Shingle)
.IV•
vlki
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Distl-
Bot Up
Depth
Top Up Dist R
Bot Up
Window
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 3
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 4
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 5
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 6
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 7
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 8
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Window 9
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 10
2
0.1
2
2
0
0
0
0
0
0
0
0
Window 11
16
0.1
16
16
�`v0
0
0
0
0
0
0
0
0
Window 12
16
0.1
16
16 <
0
0
0
0
0
0
0
0
0
Window 13
16
0.1
16
16,,.0
0
0
0
0
0
0
0
0
0
Window 14
2
0.1
2
0
0
0
0
0
0
0
0
0
Window 15
2
0.1
2
0
0
0
0
0
0
0
0
0
Window 16
2
0.1
2
2
0
0
0
0
0
0
0
0
0
zl%lr
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Type
Framing
Total Cavity R -value
Assembly Layers
Construction
2x4 Top Chord of
Cavity /Frame: no insul. / 2x4 Top Chrd
Roof Truss @ 24 in.
Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: Light Roof (Asphalt Shingle)
.IV•
vlki
Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall
Exterior Walls'
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
Exterior Finish: Wood Siding/sheathing/decking
Inside Finish: Gypsum Board
0
Cavity / Frame. R-9.1 / 2x4
R-38 Roof Attic
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
NA
AV
Registration Number: ot t4
CA Building Energy Efficiency Stan bids - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CFI R -PRF -01
Page 7of10
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated
Slab -on -Grade Whole House 1992 16 None 0.8 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required —
t9
WATER HEATING SYSTEMS
A
01 02 �_ 03 04
Name Distribution Type �'r Number of Heaters Solar Fraction (°k)
DHW Sys 1 Pipe Insulation, All Lines ��� 1 0.0%
01
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
P�
Tank Type a®vim
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage,
50
0.65
43000-Btu/hr
0
0
Aw0"
WATER HEATING - HERS VERIFICATION
s
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1-hers-dhw
n/a
Na
n/a
n/a
n/a
_R
HVAC SYSTEMS ,PA,.
01
02 ��
03
04
05
06
07
�.
e �r
Heating System
Cooling System
%
Distribution
Floor Area
Name
Syy"tem Type
Name Ducted
Name Ducted
System
Fan System
Served
Whole House1
Other Heat ng and Cooling System
Heating Component 1
Yes
Cooling
Yes
Air Distribution
HVAC Fan 1
1992
R
Component 1
System 1
.0
Registration Number:
CA Building Energy Efficiency Stands - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
CF1 R -PRF -01
Page 8of10
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Name
Verified Airflow
Efficiency
Verified EER
Multi -speed
Verified Refrigerant
Charge
Name
System Type
EER SEE
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond -Split air conditioning
12.5
1.
No
No
Cooling Component
Not Required Not Required
system
1 -hers -cool
L 7u
HVAC COOLING - HERS VERIFICATION Ao
01
02
03
04
05
06
Name
Verified Airflow
xv
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
35,0
Required
Required
Required
N
HVAC - DISTRIBUTION SYSTEMS J2
01
02
03
04
05
06
07
08
Name
Type
Duct Leak age-"��
Insulation R -value
Supply Duct
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in attic
Specified L�e�
Leakage get
8
Attic
Attic
None
Air Distribution
System 1 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
010
01
02 f"
1%"W 03
04
05 06
61
Verified Duct Design
Name
Duct Leakage VerificA�tt',on
Duct Leakage Target (°k)
Verified Duct Location
Return Supply
Air Distribution System 1 -hers -dist
Required 1
6.0
Not Required
Not Required Not Required
HVAC -FAN SYSTEMS
01 02 03 04
Name g'/ Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1` Single Speed PSC Furnace Fan 0.58 Required
Registration Number:,�� Registration Date/Time:
CA Building Energy Efficiency Standa ds - 2013 Residential Compliance Report Version - CF1R-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 9of10
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan Required 0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Name
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
49.92
0.25 AWDefault
0
Required
14PRegistration Number:
CA Building Energy Efficiency Stand`afds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 13:55, Tue, Sep 09, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CFI R -PRF -01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Aut or Signature:
Joan D. Hacker
Company:
Signature Date:
Insu-form, Inc.
9/9/2014
Address:
CEA/HERS Certification Identification (If applicable):
77810 Las Montanas Road, Suite 201
City/Stat ip:
Falco Desert, Ca 92211
Phone:
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California: o��
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility %tee building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this CertificateCompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency��for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Company: �y, `
Date Signed:
Address: ��
License:
City/State/Zip: Q
1
Phone:
0
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-09042014-650
HERS Provider:
Report Generated at: 2014-09-09 13:58:56
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 WAR
Project Name
Date
R.W. Real Estate
191912014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown, elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets therequirements of 10-111 (a).
110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form.
§110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor.
150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 24orequivalent U -factor.
*§1 50.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor.
150.0 : Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form.
150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0 ern -/inch and shall be protected from physical damage and UV light deterioration.
§150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the
requirements of either Item 1 or 2 below:
1. Fenestration, including skylight products, must have a maximum U -factor of 0.58.
2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58.
EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is
reater, is exempt from the maximum U -factor requirement.
150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device.
§150.0(e)2: Continuous buming pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building,are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §110.3(c)5.
§110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA.
150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c .
§150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally
wrapped with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
EnergyPro 6.3 by EnergySoft User Number: 2655 /D: Page 13 of 16
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
R.W. Real Estate
191912014
§150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE
120.3-A.
i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank.
ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger.
iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter.
iv. Piping from the heating source to storage tank or between tanks.
v. Piping buried below grade.
vi. All hot water pipes from the heating source to the kitchen fixtures.
§150.06)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards
Table 120.3-A.
150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§150.06)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
§150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC
Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed
level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that
meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic
or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150.0(m)7: Exhaust fans stems have back draft or automatic dampers.
§150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150.0(m)10: Flexible ducts cannot have porous inner cores.
§150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include
all the following components :
A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions;
B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water
heater is installed;
C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining
without pump assist,
D. A gas supply line with a capacity of at least 200,000 Btu/hr.
§150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality
in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150.0 : Residential pool systems orequipment meet the pump sizing,flow rate piping,filters and valve requirements of §150.0(p).
Residential Lighting Measures:
§150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance
with TABLE 150.0-A or TABLE 150.0-B as applicable.
150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c).
150.0 k 1 D: Ballasts for fluorescent lams rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz.
§150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume
no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not
be required to be controlled by vacancy sensors.
EnergyPro 6.3 by EnergySoft User Number: 2655 ID: Page 14 of 16
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
R. W. Real Estate
1911912014
150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens shall meet the applicable requirements of §150.0(k).
150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2.
§150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts
for dwelling units larger than 2,500 ftz may be exempt from the 50 percent high efficacy requirement when all
lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also
controlled by vacancy sensors or dimmers.
§150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
§150.0(k)5: Lighting installed in bathrooms shall meet the following requirements:
A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and
B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be
high efficacy, or shall be controlled by either dimmers or vacancy sensors.
EXCEPTION 1: Luminaires in closets less than 70 square feet.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site.
§150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air
leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on
the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items
ii or iii below, and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and
automatically reactivates the motion sensor within 6 hours
iii. Controlled by one of the following methods:
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and
which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements:
At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9;
meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in
Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
§150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and
outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with Section 150.0(k)9A; or
ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or
Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall
comply with the applicable requirements in Sections 110.9 130.0 130.2 130.4 140.7 and 141.0.
§150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume
no more than five watts of power as determined according to §130.0(d).
§150.0(k)11: Lighting for residential parking garages for eight or more
vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,
130.4 140.6 and 141.0.
§150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent
or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
§150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than
20 percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
EnergyPro 6.3 by EnergySoft User Number: 2655 ID: Page 15 of 16
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
R.W. Real Estate
Date
9/9/2014
System Name
Whole House
Floor Area
1,992
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
1,029
0
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 70,000
24,524
2,073 648
23,781
Total Output Btuh 70,000
0
Output Btuh/ ft 35.1
1,416
1,169
Cooling System
01
0
Output per System 58,000
0
0 0
0
Total Output Btuh 58,000
0
2,073
0
Total Output ons 4.8
1,416
1,169
Total Output Btuh/s ft 29.1
Total Output s ft/Ton 412.1
27,355
26,118
Air System
CFM per System
2,210
HVAC EQUIPMENT SELECTION
Airflow ctm
2,210
BDP CO. 561AJ060-"
43,872 5,839
70,000
Airflow cfm/s ft
1.11
70,000
Jan 1 AM
Airflow cfm/Ton 457.2
Outside Air °/6 0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
43,872 5,839
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 70 OF
O
Outside Air
0 cfm Supply Fan
2,210 cfm
70 OF
70 OF 105 OF
Heating Coil
_
105 OF
'ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 79/63°F 79/63°F 55/54°F
•
Outside Air
0cfm Supply Fan Cooling Coil
2,210 cfm
79/63 OF
1
CITY OF IA QUINTA4 OF
BUILDING & SAFETY DE
AP OR
FOR CONSTRUCTION7t3/s3 F
DATE BY
Energ Pro 6.3 by Ener Soft User Number: 2655 RunCode: 2014-09-09T14:00:35 /D: Pae 16 of 16
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence
Calculation Description: Title 24 Analysis
Calculation Datefrime: 15:03, Tue, Nov 25, 2014
Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 1 of 9
GENERAL INFORMATION
01
Project Name Single Family Residence
02
Calculation Description Title 24 Analysis
03 This building Incorporates one or more Special Features shown below
03
Project Location 54640 Avenida Carranza, 54310 Avenida Obregon
04
A City La Quinta
05
Standards Version Compliance 2014
06
Zip code
07
Compliance Manager Version BEMCmpMgr 2013-3 (651)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.3
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 180
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 1992
15
Number of Zones 1
16
Slab Area (FT2) 1992
17
Number of Stories 1
18
Addition Cond. Floor Area N/A
19
Natural Gas Available Yes
20
Addition Slab Area (FT2) N/A
21
Glazing Percentage (°k) 15.4%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building Incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building Incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04 05
06
07
08
Energy Use Standard
(kTDV/ft) Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 3.70
4.33
-0.63
-17.0%
Space Cooling 104.49
105.74
-1.25
-1.2%
IAO Ventilation 1.12
1.12CITY
:0'0
0.0%
Water Heating 12.58
10.49?T-
RAFT1 nPPT
I 16.6%
Photovoltaic Offset ----
0.00
D17r0 % /I` Q
—
Compliance Energy Total 121.89
121.68O
Q�. 1 `T T RLjr
0.2%
EO
tel 14.Yk
Registration Number: 214-No147237A-000000000-0000 Registration Date/Time: 2014-12.02 22:39:25 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26
'-
s �nfr�'..�3+� a ,,)�. r.+�i�i �t ► i ' i fIt
In
}rr
141.2
t
,.i aL t f + i t
ily
Ir I
rr
C1 r� •' I 1 ,+ ,r `' ' ?; t :I � e: .". � r �? � � � , j •c } n } :' it j f ( ! { �
ili } t rl , r � s•': ! � � n: 1 ,-. 1 _.. s (t + (.. «Y � 4 1 i j 1 � , 1
i T 4l l
{ir
�_
is
p i
rr
I Mwt.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence
Calculation Description: Title 24 Analysis
Calculation Datelrime: 15:03, Tue, Nov 25, 2014
Input File Name: RW Real Estate Residence.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ducts with high level of Insulation
• Window overhangs and/or fins
HERS FEATURE SUMMARY
CF1 R -PRF -01
Page 2 of 9
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
IAQ mechanical ventilation
Cooling System Verifications:
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
•
—None — ' «�, '7 r. �..: a ,wr •. -. /! .. ,-w p 7�"�ry
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach forthe Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating MarginPercent Improvement
Total Energy (kTDV/f2)• 169.72 169.51 0.21 0.1%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Family Residence
1992
1
3
1
0
1
Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation DaterrIme: 15:03, Tue, Nov 25, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 3 of 9
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Whole House
Conditioned
Whole Houses
1992
11
DHW Sys 1
Gross Area (ft2)
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tllt(deg)
Front Wall
Whole House
R-21 Wall
270
Left
1000
171.999
90
Left Wall
Whole House
R-21 Wall
0
Back
1000
40
90
Rear Wall
Whole House
R-21 Wall
90
Right
1000
28.4976
90
Right Wall
Whole House
R-21 Wall
180
Front
1000
65.5056
90
Roof
Whole House
R-38 Roof Attic
1992
ATTIC
> 1
01 02 t 03;. _ �i 04 ` 05 06 07
Name t Construction �� , Roof Rise- Roof Reflectance.` Roof Emittance Radiant Barrier Cool Roof
Attic Attic Roof Cons . 0 0.1 0.85 Yes No
Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance. Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 4 of 9
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multiplier
Area
(W)
1.1 -factor
SHGC
Exterior Shading
Window
Window
Front Wall (Left -270)
4.9
10.0
0.837
41.0
0.40
0.30
Insect Screen (default)
Window 2
Window
Front Wall (Left -270)
6.0
10.0
1
60.0
0.40
0.30
Insect Screen (default)
Window 3
Window
Front Wall (Left -270)
4.5
10.0
0.911
41.0
0.40
0.30
Insect Screen (default)
Window 4
Window
Front Wall (Left -270)
3.9
10.0
0.769
30.0
0.40
0.30
Insect Screen (default)
Window 5
Window
Left Wall (Back -0)
4.0
5.0
1
20.0
0.40
0.30
Insect Screen (default)
Window 6
Window
Left Wall (Back -0)
4.0
5.0
1
20.0
0.40
0.30
Insect Screen (default)
Window 7
Window
Rear Wall (Right -90)
4.0
1.5
1
6.0
0.40
0.30
Insect Screen (default)
Window 8
Window
Rear Wall (Right -90)
9.0
1.2
0.972
10.5
0.40
0.30
Insect Screen (default)
Window 9
Window
Rear Wall (Right -90)
4.0
1.5
1
6.0
0.40
0.30
Insect Screen (default)
Window 10
Window
Rear Wall (Right -90)
4.0
1.5
1
6.0
0.40
0.30
Insect Screen (default)
Window 11
Window
Right Wall a(Fro.nt-180)
1.9- _
_9.0
0.936
16.0
0.40
0.30
Insect Screen (default)
Window 12
Window
r Right-VVall (Front -180)
3.0. ``
8.0%;_
1
24.0
0.40
0.30
Insect Screen (default)
Window 13
Windowght
Wall (Front7180) ' r
3.0
1".0
1
3.0
0.40
0.30
Insect Screen (default)
Window 14
Window
' / 1 '' Right Wall (Front -180)
5.0*.,.."
;1:5
' ,k 1, :_ ,
7.5
0.40
0.30
Insect Screen (default)
Window 15
Window
Flight Wall (Front -180)
5.0
1.5
1
7.5
0.40
0.30
Insect Screen (default)
Window 16
Window
Right Wall (Front -1 80)5.0
1.5
1
7.5
0.40
0.30
Insect Screen (default)
Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Datefrime: 15:03, Tue, Nov 25, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 5 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R -value
Assembly Layers
01
02
03
04
05
06
07
O6
09
10
11
12
13
14
O.C.
none
- Roofing: Light Roof (Asphalt Shingle)
Overhang
Left Fin
- Inside Finish: Gypsum Board
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
Top Up Dist R
Bot Up
Window
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 3
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 4
10
0.1
10
10
0
0
0
0
0
0
0
0
0
Window 5
2
0.1
2
2-
0
0
0
0
0
0
0
0
0
Window 6
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 7
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 8
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Window 9
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 10
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 11
, "16:.
0.1)
16 i
16 ... ,.
10' ',
0 : "
, 0
0
0
0
0
0
0
Window 12
16
° 0.1.1
16
16 ,. a
0
0
0
0
0
0
0
0
0
Window 13
16,4/
0.1 i
160 ,
16'
0
01,
0.
0
0
0
0
0
0
Window 14
2
0.1-:
2
2
0
0
0
0
0
0
0
0
0
Window 15
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 16
2
0.1
2
2
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R -value
Assembly Layers
2x4 Top Chord of
- Cavity/Frame: no insul. /2x4 Top Chrd
Roof Truss @ 24 in.
- Roof Deck: Wood Siding/sheathing/decking
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
- Roofing: Light Roof (Asphalt Shingle)
- Inside Finish: Gypsum Board
- Cavity/Frame: R-21 /2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
- Exterior Finish: Wood Siding/sheathing/decking
- Inside Finish: Gypsum Board
- Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
- Over Floor Joists: R-28.9 insul.
Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014
Calculation Description: Title 24 Analysis
Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
-Page 6 of 9
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated
Slab -on -Grade Whole House 1992 16 None 0.8 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required ---
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0%
WATER HEATERS
t -
01
02 ' �'
03 1
04 '
05
06
07
08
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
Tank Exterior
WA
WA
- '
N/A
Tank Volume
Energy Factor or-
Other Heat/Cool
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
(gal)
Efficiency
Input Rating
R -value
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.65
43000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
WA
WA
WA
N/A
N/A
WA
HVAC SYSTEMS
01
02
03
04
05
06
07
Heating System
Cooling System
Distribution
Floor Area
Name
System Type
Name Ducted
Name Ducted
System
Fan System
Served
Whole Housel
Other Heat/Cool
Heating Component 1
Yes
Cooling Component 1
Yes
Air Distribution
System 1
1992
Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence
Calculation Description: Title 24 Analysis
Calculation Datefrime: 15:03, Tue, Nov 25, 2014
Input File Name: RW Real Estate Residence.xml
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
CF1 R -PRF -01
Page 7 of 9
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Name
}., Verified Airflow
Efficiency
Verified EER
Muld-speed
Verified Refrigerant
Charge
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
12.5
15
No
No
Cooling Component
Ducts located in attic
system
8
Attic
Attic
None
1 -hers -cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
}., Verified Airflow
,-, Air(Iow,Targetr__ _
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
'i- Requiredi.
+ i 350 ]
=Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04`
05
06
07
08
Verified Duct Design
Low -leakage
Supply Duct
Verification
Duct Leakage Target (%)
Verified Duct Location
Name
Type
Duct Leakage
Insulation R -value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in attic
Specified Lower
8
Attic
Attic
None
Air Distribution
Leakage Target
System 1 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
07
Duct Leakage
Verified Duct Design
Low -leakage
Name
Verification
Duct Leakage Target (%)
Verified Duct Location
Return Supply
Air Handler
Air Distribution System
Required
6.0
Not Required
Not Required
Not Required
Required
1 -hers -dist
Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-02 22:39:25 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Datefrime: 15:03, Tue, Nov 25, 2014
Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml
CF1 R -PRF -01
Page 8 of 9
HVAC -FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan Required 0.58
IAO (Indoor Air Quality) FANS
01
02
03
04
05
06
Name
IAQ CFM
IAO Watts/CFM
[AQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
DwellingUnit
49.92
0.25
Default
0
Required
Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Single Family Residence Calculation Date/Time: 15:03, Tue, Nov 25, 2014 Page 9 of 9
Calculation Description: Title 24 Analysis Input File Name: RW Real Estate Residence.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
7�
Joan Hacker
ta
J"un c!-cr7er
Company:
Signature Date:
Joan Hacker
2014-12-02 09:01:47
Address:
CEA/HERS Certification Identification (If applicable):
77810 Las Montanas Road, Suite 201
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified ornthis Certificate ofCompliance are consistent. with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this.building permit application.
Responsible Designer Name: i ?
Responsible DesignerSignature:.
Gabriel Rios
o
Company:
Date Signed:
Rios Designs
2014-12-02 22:39:25
Address:
License:
49-901 Cinnabar Lane
na
City/State/Zip:
Phone:
Coachella, CA 92236
760-485-7431
CITY OF LA QUINT -A
BUILDING�y�&�SAAFET�—Y�DEPT.
Digitally signed by CaICERTS. This digital signature is provided in order to secure PEonte"nt'of°thi r stpr�'d docum nt and in noway implies Registration Provider responsibility for the accuracy of the
IV CONSTRUCTION
information.
[DATE_. BY
Registration Number: 214-N0147237A-000000000-0000 Registration Date/Time: 2014-12-0222:39:25 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-25 15:05:26