Loading...
0001-034 (SFD) Title 24FROM Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 20eO 11:51AM P3 Carole Christensen, Certified Energy Analyst Title -24 Energy Calculations January 4, 2000 ENERGY CALCULATIONS FOR: Lendel Ventures, laic. P.O. Box 450 La Quinta, CA 92253-0450 PROJECT: Plan Taos -1696 sq.ft. LaQuinta, CA 92253 Standard Proposed COMIDliance East 60.94 60.19 +0..75 West 60.94 57.67 +3.27 CTZ-15 16.8% fenestration Dual Aluminum fenestration, Philips or better, Walls R- 13+1 "Falcon; Roof R-38. Duct RA.2 AFUE 80%, SEER 12.0 One 50 gal gas water heater, EF .58 Table of Contents CFA R MF -IR C -2R 3-R HVAC Fenestration Specifications This plan run in Cardinal orientations but will be built East and West only. 47.5Y6 Lake C•anywm Drive. Aguanga. CA Y2536 1-800-735-8152 (:ABCC Ce.fined EnerV Anolysr - Ca(ifornio Asnclarion of Building V-ncrry Con»drano FROM : Christensen/T-24/CASEC FAX NO. : 909 763 0522 Jan. 04 2000 11:52AM P4 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Plan Taos 1696 Date.-. 01/04/0-0 10:17:52 Project Address........ ******* La Quinta, Ca Documentation Author... Carole Christensen ******* Building ermit Carole Christensen 47-596 Lake Canyon Drive Plan Check Date Aguanga, CA 92536 800-735-8152 Field Check/ate Climate Zone. 15 Compliance Method...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc. MICROPASS v5.00 File-TAOS1696 Wth-CTZ1SS92 Program -FORM CF -1R User#-MP1.017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type.... Glazing -Percentage ......... Average Glazing U -value.... Average Glazing SHGC....... 1696 sf Single Family Detached New Cardinal - N,E,S,W 1 1 . Slab On Grade 16.8 : of floor area 0.75 Btu/hr-sf-F 0.69 BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R -value R -value R -value U -value Location/Comments Wall Wood R-13 R-4.61 R-17.61 0.060 Wall Wood R-13 R-0 R-13 0.086 Door None R-0 R-0 R-0 0.330 To garage Roof Wood R-11 R-27 R-38 0.025 Flat S1abEdge None R-0 R-0 F2=0.760 to outside S16bEdge None R-0 R-0 F2=0.510 To garage FENESTRATION Over - Area U- Interior Exterior hang/ Orientation (st) Value SHGC Shading Shading Fins Window Front (N) 6.0 0.630 0.720 Standard Standard Yes Door Front (N) 33.3 0.850 0.700 Standard Standard None Window Front (N) 10.0 0.630 0.720 Standard Standard None Window Left (E) 25.0 0.720 0.670 Standard Standard None Window Left (E) 9.0 0.720 0.670 Standard Standard None Window Left (E) 30.0 0.720 0.670 Standard Standard None Door Left (E) 33.3 0.850 0.700 Standard Standard None Window Left (E) 24.0 0.630 0.720 Standard Standard None Door Back (S) 33.3 0.850 0.700 Standard Standard None Window Back (S). 10.0 0.630 0.720 Standard Standard None Window. Back (S) 10.0 0.630 0.720 Standard Standard None Window Right (W) 4.0 0.720 0.670 Standard Standard None Window Right (W) 12.4 0.550 0.700 Standard Standard None Window Right (W) 16.0 0.720 0.670 Standard Standard None Window Right (W) 16.0 0.720 0.670 Standard Standard None FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:52AM P5 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title........... Plan Taos 1696. Date'. .01/04/00 10:17:52. MICROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM CF -1R User#-MP101.7 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 Orientation Skylight Horz Skylight Horz Skylight Horz Equipment Type Furnace ACSplit WATER HEATING SYSTEMS Tank Type Heater Type Distribution Type Storage Gas Standard Number FENESTRATION External in Energy Size Insulation System Factor (gal) Over - Area U- Interior Exterior hang/ (sf) value SHGC Shading Shading Fins 4.0 0.940 0.730 None None None 4.0 0.940 0.730 None None None 4.0 0.940 0.730 None None None SLAB SURFACES Area Slab Type (sf) Standard Slab 1696 HVAC SYSTEMS Minimum Duct Duct Tested Duct ACCA Thermostat Efficiency Location R. -value Leakage Manual D Type 0.800 AFUE Attic R-4.2 No No Setback 12.00 SEER Attic R-4.2 No No Setback WATER HEATING SYSTEMS Tank Type Heater Type Distribution Type Storage Gas Standard Number Tank External in Energy Size Insulation System Factor (gal) R -value 1 0..58 SO R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building ,with no orientation restrictions. This printout is for the front facing North. REMARKS Philips Fenestration or better FROM Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:53AM P6 CERTIFICATE OF.COMPLIANCE: RESIDENTIAL Page 3 CF -1R, Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:52 MICROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen Run7VbF80.10.R13Falc38.4EF60 COMPLIANCE STATEMENT This certificate of compliance lists the building features.and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has-been signed by the of with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... A.P. Lench, II, President Name.... Carole Christensen Company. Lendel Ventures, Inc. Company. Carole Christensen Address. P.O. Box 450 Address. 47-596 Lake Canyon Drive La Quinta, Ca 92253-0450 Aguanga, CA 92536 Phone... (760) 5 -1866 Phone... 800-735-8152 - - License. #638 35 Signed.. Signed.. a/te ate E FORCEMENT AGENCY ! el - a G Name ... Title... Agency.. Phone... Signed. ate Certified anergy AAAIyst', Comte Christe,wen, CEPS r r R 9&99,239 r r ICAIEC -- Californio association or tb0idirig Energy COMUltm-A FROM ChriS.tenSen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:54AM P7 , MANDATORY MEASURES CHECKLIST: RESIDENTIAL (page 1 of 2) Iff-IR Note: Lowrise residential building subject to the Standards must contain these measures rogardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the C rtiftcatc of Compliance. When this checklist is incorporated into the permit documents, the ledurt:s noted iiWl be considered by all parties to minimum component performemcc spcciftcatioas for the mandatury measures whether they, are shown clscwhem in the documents or on this checklist only. Instructions: Check or initial .applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures: • §150(4): Minimum R- 19 ceiling insulation. §150(b): Goosc fill insulation manufacturer's labeled R-Valuc. • § 1 SOW: Minimums R-13 wall insulation in wood framed walls or equivalent U -value in metal fnhrne wails dots not apply to exterior trues walls). 4150(d): Minimum R-13 raised floor insulation in fsw r.W (Soon. 41 §15W): Slab edge insulation - water absorption rate no greats than 0.3%, water vapor transmission rate no rester than 2.0 permlinch. / V ¢1l9: Insulation specified or installed meets insulation quality standards. Indicate type and form. § 116-17: Fenestration Products, Exterior Doors, and lnfiltmion/Ex41tration Controls 1. Doors and windows between conditioned and unconditioned wets designed to limit air )eakagt. 2. Fenestration products (except field•fabcicaad)h3ve label with certified 11 -value, ceniticd Solar Heat Gain Coefficient (SHCC), and infiltration certification / 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and scaled. ¢ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. q/ ¢ 150(0: Special infiltration barrier installed.to comply with ¢ 151 meas Commission quality standards. §150(e): installation ofFimplaccs, Decorative Gas Appliances and Gas Logs. 1. Masonry and fsctory-buh7t fireplaces have: a. Closable metal or glass door b. Outside air intake with damper and control e. Flue damper and control 2. No continuous burning gas pilot lights allowed. Space Conditioning, Water Heating and Plumbing System Measures: HVAC cquipmcro, orator heaters, showerheads and teuects certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with A.SHRAE, SMACNA or ACOA. §00(i); Setback thermostat oo all applicable hentiag and/or cooling systems. §L506): Pipe and tank insulation 1. Storage gas water haters rated with an Energy Factor less than 0.59 must be exttmally wrapped with. insulation having an installed thermal resistance of R-12 or grater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systema, insulated (R4 or greater) 3. Backup tanks for solar systcrn, untircd smsagc tanks, or other indirect hot water tanks have k-12 external insulation or R-16 combined internaUtmemal insulation. 4. All buried or exposed piping insulated in recirculating scstions of hot water systems. 5. Calling systehn piping below 55" F insulated. & Piping insulated between heating source and mditect hot water tank. July 1, 1999 FROM F ChriStenSer✓T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:54AM PS MANDATORY MEASURES CHECKLIST: RESIDENTIAL(page 2 of 2) MF -1R Note: Lowrise residential buildings subject to the Standards must contain that mcmntres regardless of the compliance approach used. Items marked with an asterisk (a) may be superseded by more stringent t ompliancc requirancttts listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents. the features rated shall be considered by all parties as minimum component performance specifications for the mxndrwhry me "ores whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or Initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Space Conditioning, Water Heating and plumbing System Measures: (continued) • § 150(m): Ducts and Fans I. All ducts and plenums constructed. itutalkd, iasulased, fastened, and sealed to comply with the 1CBO 1997 UMC sections 601 and 603; ducts inpdaied to a minimum installed R-41 or ducts enclosed entirely within conditioned space. Openings shall be scaled with mastic, tape, aerosol sealant or other duct closure system that meets the applicable requiremetas ofUL181, UL 191 A, or UL 18IB and other applicable specified tests for longevity given in §Iwm).. 2. Exhaust fan systems have back dn8 or autonsatic dampcts. 3. Gravity ventilating systems serving conditioned space have tither automatic or readily accessible, manually / operated dampers. § 114: Pool and Spa Heating Systcau and Equipment. 1. System is crd&d with 78% thermal efficiency. un -off swiOL wtsihaproof operating . instructions, no electric resistance beating Gad no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor poets or outdoor spas. 3. Pool system las directional inlets and a circulation pump time switch. § t IS: Gas find antral furnaces, pool beatats, spa heaters or bousebold cooking appliances have no continuously burning pilot light. (Exce rptioni Non -electrical cooking appliances with pilot < 150 Bturlhr Lighting Measures: §150(k)l.: Luminaires for getieral lighting in kitchens shall have lamps with an efficacy of40lumens/wan or greater for general lighting in kitcheiu. This gatesl lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. § I Wk)2.: Rooms with a shower or bathtub must either have at lcaat one luminaire with lamp with an efficacy of 40 lumenVwati or greater switched at the entrance to the room or one of the attematives to this requirement allowed in j 150(k)2.: and recessed Ceiling fixtures arc IC insulation cover) (4pproved. July 1, 1999 FROM :- Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:55AM P9 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title:..•.....•. Plan Taos 1696 Date. .01/04/00 10.1'7:52 Project Addre:ss........ ******* La Quinta,'Ca *v5.00* Documentation; Author,.. Carole Christensen ******* Building Permit Carole Christensen 47-596 Lake Canyon Drive Plan Check 7 Date Aguanga, CA 92536 800-735-8152 FieTZ1 Che-ER7Date Climate Zone. ..... 15 Compliance Me;thod...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc. MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 GENERAL INFORMATION Conditioned Floor Area..... 1696 sf Building Type .............. Single Family Detached. Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type........... ReducedYear. Floor Construction Type.... Slab On Grade Number of Building Zones... 1 MICROPAS5 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin. Space Heating.......... 3.24 2.39 0.85 Space Cooling.......... 43.20 45.9 -2.73 Water Heating.......... '14.50 13.06 1.44 North Total 60.94 61.38 -0.44 Space Heating.......... 3.24 2.37 0.87 Space Cooling.......... 43.20 44.76 -1.56 Water Heating.......... 14.50 13.06 1.44 East Total 60.94 60.19 0.75 Space Heating.......... 3.24 2.87 0.3.7 SpaCe Cooling.......... 43.20 45.16 -1.96 Water Heating.......... 14.50 13.06 1.44 South Total 60.94 61.09 -0.15 Space Heating.... 3.24 2.96 0.28 Space Cooling.......... 43.20 41.65 1.55 Water Heating.......... 14.50 13.06 1.44 West Total 60.94 57.67 3.27 **:* Building does not comply with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... 1696 sf Building Type .............. Single Family Detached. Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type........... ReducedYear. Floor Construction Type.... Slab On Grade Number of Building Zones... 1 FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:56AM P10 COMPUTER METHOD SUMMARY Page 2 C -2R Project Title........... Plan Taos 1696 Date..01/04/00 10:17:52 MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 Zone Type HOUSE Residence Conditioned Volume......... 16960 cf Slab -Ori -Grade Area......... 1696 sf Glazing Percentage......... 16.8 t of floor area Average Glazing TJ -value .... 0.75 Btu/hr-sf-F Average Glazing SHGC....... 0.69 Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage (sf) (cf) Units itioned Type (ft) (s£) Credit 1696 16960 1.00 Yes Setback 2.0 Standard No Location/ Comments To garage Flat Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE 9 S1abEdge 160 10 SlabEdge 28 orientation HOUSE 1 Window Front (N) 2 Door Front (N) OPAQUE SURFACES Front (N) 4 Area U- Insul Act Solar Form 3 Surface (sf) value R-val Azm Tilt'Gains Reference HOUSE (E) 8 Window' Left (E) 9 1 Wall 131 0.060 17.61 0 90 Yes W13.2X4.16FA 2 Wall 459 0.060 17.61 90 90 Yes W13.2X4.16FA 3 Wall 347 0.060 17.61 180 90 Yes W13.2X4.16FA 4 Wall 392 0.060 17.61 270 90 Yes W13.2X4.16FA 5 Wall 263 0.086 13 0 90 No GARWALLR13 6 Door 20 0.330 0 270 90 No None 7 Door 17 0.330 0 0 90 No None 8 Roof 1684, 0.025 38 n/a 0 Yes R.38.2X4.24 PERIMETER LOSSES Location/ Comments To garage Flat Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE 9 S1abEdge 160 10 SlabEdge 28 orientation HOUSE 1 Window Front (N) 2 Door Front (N) 3 Window Front (N) 4 Window Left (E) 5 Window Left (E) 6 Window Left (E) 7 Door Left (E) 8 Window' Left (E) 9 Door Back (S) 10 Window Back (S) 0.760 R-0 No to outside 0.510 R-0 No To garage FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC 6.0 0.630 0.720 0 90 Standard/0.76 Standard/0.68 33.3 0.850 0.700 0 90 Standard/0.76 Standard./0.68 10.0 0.630 0.720 0 90 Standard/0.76 Standard/0.68 25.0 0.720 0.670 90 90 Standard/0.76 Standard/0.68 9.0 0.720 0.670 90 90 Standard/0.76 Standard/0.68 30.0 0.720 0.670 90 90 Standard/0.76 Standard/0.68 33.3 0.850 0.700 90 90 Standard/0.76 5tandard/0.68 24.0 0.630 0.720 90 90 Standard/0.76 Standard/0.68 33.3 0.850 0.700 180 90 Standard/0.76 8tandard/0.68 10.0 0.630 0.720 180 90 Standard/0.76 Standard/0.68 FROM ChriStensen/T-24/CABEC FAX N0. : 909 763 0522 Jan. 04 2000 11:56AM P11 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:5.2 MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 Orientation 11 Window Back (S) 12 Window Right (W) 13 Window Right (W) 14 Window Right M 15 Window Right (W) 16 Skylight Horz 17 Skylight Horz 18 Skylight Horz FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC 10.0 0.630 0.720 180 90 Standard/0.76 Standard/0.68 4.0 0.720 0.670 270 90 Standard/0.76 Standard/0.68 12.4 0.550 0.700 270 90 Standard/0.76 Standard/0.68 16.0 0.720 0.670 270 90 Standard/0.76 Standard/0.68 16.0 0.720 0.670 270 90 Standard/0:76 Standard/0.68 4.0 0.940 0.730 0 0 None/1 None/1 4.0 0.940 0.730 0 0 None/1 None/1 4.0 0.940 0.730 0 0 None/1 None/1 OVERHANGS AND SIDE FINS Window--- ---Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 6.0 2.0 3.0 4.0 0.5 0.5 0.5 0.5 4.0 0.5 0.5 4.0 0.5 SLAB SURFACES This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. Area Slab Type (sf) HOUSE Standard Slab 169.6 HVAC SYSTEMS Minimum Duct Duct Tested Duct ACCA Duct System Type Efficiency Location R -value Leakage Manual D Eff HOUSE Furnace 0.800 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R. -value 1 Storage Gas Standard 1 0.58 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installcd to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. FROM :` Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:57AM P12 COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... Plan Taos 1696 Date..01/04/00 10:17:52 MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 REMARKS Philips Fenestration or better FROM ' Christensen/T-24/CASEC FAX NO. : 909 763 0522 Jan. 04 2000 11:57AM P13 CONSTRUCTION ASSEMBLY Page 1 3R Project Title.......... Plan Taos 1696 Date. .'01/04/00 10:17:52 MI'CROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 Parallel Path Method Reference Name . W13.2X4.16FA Description .... WallR-13 2x4 16oclinFalc Type ........... Wall R -Value ........ 17.61 Hr-sf-F/Btu Framing Material ..... FIR.2X4. Type ......... Wood Description .. 2x4 fir Spacing 16 inches on center Framing Frac.. 0.15 'Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Total R -Value: 1 / 0.060 = 16.66 hr-sf-F/Btu Material Cavity Frame Name Description R -Value R -Value O. FILM.EX Exterior air film: winter value 0.17 0.17 1. STUCC0.0.88 0..875 in stucco 0.17 0.17 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. R 4.61 RIGID R-4.61 Insulated Sheathing 4.61 4.61 4c. BATT.R13 R-13 batt insul (cavity = 3.5 in) 13.00 -- 4f. FIR.2X4 2x4 fir -- 3.46 5. GYP.0.50 0.50 in.gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL .Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 19.15 9.61 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 19.15 x 0.85) + (1 / 9.61 x 0.15) 0.060 Btu/hr-ef-F Total R -Value: 1 / 0.060 = 16.66 hr-sf-F/Btu FROM : Christensen/T-24/CABEC FAX NO. : 909763 0522 Jan. 04 2000 11:59AM P14 CONSTRUCTION ASSEMBLY Page 2 3R Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:52 MICROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 Parallel•Path Method Reference Name . GARWALLRI3 Description .... Wall R711 2x4 16oc Type ........... Wall R -Value ........ 13 Hr-sf-F/Btu Framing Material ..... FIR.2X4 Type ......... Wood Description .. 2x4 fir Spacing ...... 16 inches on center Framing Frac.. 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS FRAMING ADJUSTMENT CALCULATION . Cavity Total Unadjusted R -Values Framing U -Value: (1 / 14.81 x 0.85) + (1 / 5.27 x 0.15) = Cavity Material R -Value R -Value 0.17 Name Description 0.45 0. FILM.EX Exterior air film: winter value 1. GYP.0.50 0.50 in gypsum or plaster board 2. BLDG.PAPER Building paper (felt) 3t. BATT.R13 R-13 batt insul (cavity = 3.5 in) 3f. FIR.2X4 2x4 fir 4. GYP.0.50 0.50 in gypsum or plaster board I. FILM.IN.WLL Inside air film: heat sideways FRAMING ADJUSTMENT CALCULATION . Cavity Total Unadjusted R -Values Framing U -Value: (1 / 14.81 x 0.85) + (1 / 5.27 x 0.15) = Cavity Frame R -Value R -Value 0.17 0.17 0.45 0.45 0.'06 0.06 13.00 -- -- 3.46 0.45 0.45 0.68 0.68 14.81 5.27 Total 0.086 Btu/hr-sf-F Total R -Value: 1 / 0.086 11.6.5 hr-sf-F/Btu FROM ; Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:59AM P15 CONSTRUCTION ASSEMBLY Page 3 3R Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:52 MICROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 Parallel Path Method Reference Name . R.38.2X4.24 Description .... Roof R-38 2x4 24oc Type ........... Roof R -Value ........ 38 Hr-sf-F/Btu Framing Material ..... FIR.2X4 Type wood Description 2x4 fir Spacing ...... 24 inches on center Framing Frac.. 0.07 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 40.92 x 0.93) + (1 / 33.39 x 0.07.) = 0.025 Btu/hr-sf-F Total R -Value: 1 / 0.025 = 40.28 hr-sf-F/Btu Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX Exterior air film: winter value 0..17 0.17 1. SHNGL.CEMENT Asphalt -cement shingles 0.21 0.21 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. PLY.0.50 0.50 in plywood 0.62 0.62 4. ATR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 0.80 5. BATT.R27.0 R-27 batt insulation 27.00 27.00 6c. BATT.RII.0 R -1i batt insul (cavity > 3.5 in) 11.00 -- 6f.. FIR. 2X4 2x4 fir -- 3.46 7. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61 Total Unadjusted R -Values 40.92 33.39 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 40.92 x 0.93) + (1 / 33.39 x 0.07.) = 0.025 Btu/hr-sf-F Total R -Value: 1 / 0.025 = 40.28 hr-sf-F/Btu .FROM Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:59AM P16 HVAC SIZING Page 1 HVAC Project Title.......... Plan Taos 1696 Date -01/04/00 10:17:52 Project Address........ ******* La Quinta,, Ca *v5.00* Documentation Author... Carole Christensen ******* Building Permit Carole Christensen 47-596 Lake Canyon Drive an Check ate Aguanga, CA 92536 800-735-8152 Field Che—c— Date Climate Zone.... ..... 15 Compliance Method...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc. MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 GENERAL INFORMATION Floor Area ................. Volume ..................... Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design,..... Summer Outside Design...... Summer Inside Design....... Summer Range........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 1696 sf 16960 cf Front Facing 0 deg (N) PALM DESERT 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Heating (Btuh) Opaque Conduction and Solar...... 11101 Glazing Conduction ............... 8091 Glazing Solar .................... n/a Infiltration ..................... 8956 Internal Gain .................... n/a Ducts ............................ 2815 Sensible Load .................... 30962 Latent Load....... ............... n/a Minimum Total Load 30962 Cooling (Btuh) 5647 7239 13777 5927 2550 3514 38654 7731 46385 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. ,FROM Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 12:00PM P17 HVAC SIZING Page 2 HVAC Project Title.......... Plan Taos 1696 Date..01/04/00 10:17:52 MICROPAS5 x5.00 File-TAOS1696 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 GENERAL INFORMATION Floor Area ................. 1696 sf Volume.....................16960 cf Front Orientation.......... Front Facing Sizing Location............ PALM DESERT. Latitude... ..... ........ 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range............... 34 F Interior Shading Used...... No Exterior Shading -Used ...... No Overhang Shading. Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING .LOAD SUMMARY Heating Description (Btuh) Opaque Conduction and Solar...... 11101 Glazing Conduction ............... 8091 Glazing Solar .......... ........... n/a Infiltration ..................... 8956 Internal Gain .................... n/a Ducts ............................ 2815 Sensible Load .................... 30962 Latent Load..'. ................... n/a Minimum Total Load 30962 90 deg (E) Cooling (Btuh) 5647 7239 11680 5927 2550 3304 36347 7269 43617 Note: The loads shown,are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc.., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 12:00PM P18 HVAC SIZING Page 3 HVAC Project Title........... Plan Taos 1696 Date..01/.04/00 10:17:52 MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -HVAC SIZING User#-MP.1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60 GENERAL INFORMATION Floor Area ................. 1696 sf Volume..: .... *............ 16960 cf Front Orientation.......... Front Facing Sizing Location............ PALM DESERT Latitude... .... ........ 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design........ 78 F Summer Range ............... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction........ 0.20 Description HEATING AND COOLING LOAD SUMMARY Heating (Btuh) Opaque Conduction and Solar...... 11101 Glazing Conduction ............... 8091 Glazing Solar..................... n/a Infiltration ..................... 8956 Internal Gain .................... n/a Ducts .................. I......... 2815 Sensible Load .................... 30962 Latent Load ...................... n/a 180 deg (S) Cooling (Btuh) 5647 7239 13719 5927 2550 3508 38590 7718 Minimum Total Load 30962 46308. Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered., It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. „FROM Christensen/T-24/CAHEC FAX NO. : 909 763 0522 Jan. 04 2000 12:01PM P19 HVAC SIZING Page 4 HVAC Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:52 MICROPAS5 v5.00 File-TAOS16.96 Wth-CTZ15S92 Program -HVAC SIZING User4-MP1017 User -Carole Christensen Ruh-VbF80.10.R13Falc38.4EF60 GENERAL INFORMATION Floor Area .................. volume ..................... Front Orientation.......... Sizing Location............. Latitude... ............. Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 1696 s£ 16960 cf Front Facing 270 deg (W) PALM DESERT 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Stuh) (Etuh) Opaque Conduction and Solar...... 11101 5647 Glazing Conduction ............... 8091 7239 Glazing Solar .................... n/a 10653 Infiltration ..................... 8956 5927 Internal Gain .................... n/a 2550 Ducts ............................ 2815 3202 Sensible Load .................... Latent Load ...................... 30.962 n/a 35217 7043 Minimum Total Load 30962 42261 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. FROM ChristenSen/T-24/CABEC FAX NO. 909 763 0522 Jan. 04 2000 12:01PM P20 ' v"' ' ',•U44 DLSMI w1NLUQW.5 PA& 67 08�OIr'6p 11.12 FAT 2IS2000016 X904CIUSupporc ®ooZ PNI 1:1�M 7.99 U0 Al W'n V U2" S u. 24011S 110riz0atti SUder Cicar/Air/C1ear .72 Clear/Ar;on/Clou .70 Cktr/i,owE/Our .57 Clr/LowE/Arg/Clr .53 Z405H 240F SintIt Hung Clear/Air/Clctr .72 Ctetr/Argon/Clear .70 Clenr/LOw-VCleai .57 Or/LowE/Ar^g/Cir 13 .67 W/ Grids .61 .67 W/ Grids .61 .38 w/ Grids .35 .3b wt Grids .35 .6; w/ Grids .61 .65 w/ Grids .61 .38 w/ Grids .35 .S8 w/ Gads .3; Picture Window Citar/Air/Clear .63 .72 wt Grids .66 Cleor/Argoa/Cltsr .60 72 w/ Grids .66 Clctr/LowFlCkir .43 . .40 w/ Grids .37 . C(r/LowEJA,rgfClr .41 .40 W/ Grids .3' Philips Products uses Spectrally Sclec&t Lo+wE Cum`ings