0001-034 (SFD) Title 24FROM Christensen/T-24/CABEC
FAX NO. : 909 763 0522 Jan. 04 20eO 11:51AM P3
Carole Christensen, Certified Energy Analyst
Title -24 Energy Calculations January 4, 2000
ENERGY CALCULATIONS FOR:
Lendel Ventures, laic.
P.O. Box 450
La Quinta, CA 92253-0450
PROJECT: Plan Taos -1696 sq.ft.
LaQuinta, CA 92253
Standard Proposed COMIDliance
East 60.94 60.19 +0..75
West 60.94 57.67 +3.27
CTZ-15 16.8% fenestration
Dual Aluminum fenestration, Philips or better,
Walls R- 13+1 "Falcon; Roof R-38. Duct RA.2
AFUE 80%, SEER 12.0
One 50 gal gas water heater, EF .58
Table of Contents
CFA R
MF -IR
C -2R
3-R
HVAC
Fenestration Specifications
This plan run in Cardinal orientations but will be built East and West only.
47.5Y6 Lake C•anywm Drive. Aguanga. CA Y2536
1-800-735-8152
(:ABCC Ce.fined EnerV Anolysr - Ca(ifornio Asnclarion of Building V-ncrry Con»drano
FROM : Christensen/T-24/CASEC FAX NO. : 909 763 0522 Jan. 04 2000 11:52AM P4
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... Plan Taos 1696 Date.-. 01/04/0-0 10:17:52
Project Address........ *******
La Quinta, Ca
Documentation Author... Carole Christensen ******* Building ermit
Carole Christensen
47-596 Lake Canyon Drive Plan Check Date
Aguanga, CA 92536
800-735-8152 Field Check/ate
Climate Zone. 15
Compliance Method...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc.
MICROPASS v5.00 File-TAOS1696 Wth-CTZ1SS92 Program -FORM CF -1R
User#-MP1.017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Stories..........
Floor Construction Type....
Glazing -Percentage .........
Average Glazing U -value....
Average Glazing SHGC.......
1696 sf
Single Family Detached
New
Cardinal - N,E,S,W
1
1 .
Slab On Grade
16.8 : of floor area
0.75 Btu/hr-sf-F
0.69
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing Total Assembly
Type
Type
R -value
R -value R -value
U -value
Location/Comments
Wall
Wood
R-13
R-4.61 R-17.61 0.060
Wall
Wood
R-13
R-0
R-13
0.086
Door
None
R-0
R-0
R-0
0.330
To garage
Roof
Wood
R-11
R-27
R-38
0.025
Flat
S1abEdge
None
R-0
R-0
F2=0.760
to outside
S16bEdge
None
R-0
R-0
F2=0.510
To garage
FENESTRATION
Over -
Area
U-
Interior
Exterior
hang/
Orientation
(st)
Value
SHGC
Shading
Shading
Fins
Window
Front (N)
6.0
0.630
0.720
Standard
Standard
Yes
Door
Front (N)
33.3
0.850
0.700
Standard
Standard
None
Window
Front (N)
10.0
0.630
0.720
Standard
Standard
None
Window
Left (E)
25.0
0.720
0.670
Standard
Standard
None
Window
Left (E)
9.0
0.720
0.670
Standard
Standard
None
Window
Left (E)
30.0
0.720
0.670
Standard
Standard
None
Door
Left (E)
33.3
0.850
0.700
Standard
Standard
None
Window
Left (E)
24.0
0.630
0.720
Standard
Standard
None
Door
Back (S)
33.3
0.850
0.700
Standard
Standard
None
Window
Back (S).
10.0
0.630
0.720
Standard
Standard
None
Window.
Back (S)
10.0
0.630
0.720
Standard
Standard
None
Window
Right (W)
4.0
0.720
0.670
Standard
Standard
None
Window
Right (W)
12.4
0.550
0.700
Standard
Standard
None
Window
Right (W)
16.0
0.720
0.670
Standard
Standard
None
Window
Right (W)
16.0
0.720
0.670
Standard
Standard
None
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:52AM P5
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title........... Plan Taos 1696. Date'. .01/04/00 10:17:52.
MICROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP101.7 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
Orientation
Skylight Horz
Skylight Horz
Skylight Horz
Equipment Type
Furnace
ACSplit
WATER HEATING SYSTEMS
Tank Type Heater Type Distribution Type
Storage Gas Standard
Number
FENESTRATION
External
in
Energy Size
Insulation
System
Factor (gal)
Over -
Area
U-
Interior
Exterior
hang/
(sf)
value SHGC
Shading
Shading
Fins
4.0
0.940 0.730
None
None
None
4.0
0.940 0.730
None
None
None
4.0
0.940 0.730
None
None
None
SLAB SURFACES
Area
Slab Type
(sf)
Standard
Slab 1696
HVAC SYSTEMS
Minimum
Duct
Duct Tested Duct ACCA
Thermostat
Efficiency
Location
R. -value
Leakage Manual
D Type
0.800 AFUE
Attic
R-4.2
No No
Setback
12.00 SEER
Attic
R-4.2
No No
Setback
WATER HEATING SYSTEMS
Tank Type Heater Type Distribution Type
Storage Gas Standard
Number
Tank
External
in
Energy Size
Insulation
System
Factor (gal)
R -value
1
0..58 SO
R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This is a multiple orientation building ,with no orientation restrictions.
This printout is for the front facing North.
REMARKS
Philips Fenestration or better
FROM Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:53AM P6
CERTIFICATE OF.COMPLIANCE: RESIDENTIAL Page 3 CF -1R,
Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:52
MICROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User -Carole Christensen Run7VbF80.10.R13Falc38.4EF60
COMPLIANCE STATEMENT
This certificate of compliance lists the building features.and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has-been signed by the of
with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER
DOCUMENTATION AUTHOR
Name.... A.P. Lench, II, President Name.... Carole Christensen
Company. Lendel Ventures, Inc. Company. Carole Christensen
Address. P.O. Box 450 Address. 47-596 Lake Canyon Drive
La Quinta, Ca 92253-0450 Aguanga, CA 92536
Phone... (760) 5 -1866 Phone... 800-735-8152 - -
License. #638 35
Signed.. Signed..
a/te ate
E FORCEMENT AGENCY ! el - a G
Name ...
Title...
Agency..
Phone...
Signed.
ate
Certified anergy AAAIyst',
Comte Christe,wen, CEPS
r r R 9&99,239
r r
ICAIEC --
Californio association or tb0idirig Energy COMUltm-A
FROM ChriS.tenSen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:54AM P7
,
MANDATORY MEASURES CHECKLIST: RESIDENTIAL (page 1 of 2) Iff-IR
Note: Lowrise residential building subject to the Standards must contain these measures rogardless of the compliance approach used.
Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the C rtiftcatc of
Compliance. When this checklist is incorporated into the permit documents, the ledurt:s noted iiWl be considered by all parties
to minimum component performemcc spcciftcatioas for the mandatury measures whether they, are shown clscwhem in the
documents or on this checklist only.
Instructions: Check or initial .applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION
DESIGNER
ENFORCEMENT
Building Envelope Measures:
• §150(4): Minimum R- 19 ceiling insulation.
§150(b): Goosc fill insulation manufacturer's labeled R-Valuc.
• § 1 SOW: Minimums R-13 wall insulation in wood framed walls or equivalent U -value in metal fnhrne wails
dots not apply to exterior trues walls).
4150(d): Minimum R-13 raised floor insulation in fsw r.W (Soon.
41
§15W): Slab edge insulation - water absorption rate no greats than 0.3%, water vapor transmission rate no
rester than 2.0 permlinch.
/
V
¢1l9: Insulation specified or installed meets insulation quality standards. Indicate type and form.
§ 116-17: Fenestration Products, Exterior Doors, and lnfiltmion/Ex41tration Controls
1. Doors and windows between conditioned and unconditioned wets designed to limit air )eakagt.
2. Fenestration products (except field•fabcicaad)h3ve label with certified 11 -value, ceniticd Solar Heat Gain
Coefficient (SHCC), and infiltration certification
/
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and scaled.
¢ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
q/
¢ 150(0: Special infiltration barrier installed.to comply with ¢ 151 meas Commission quality standards.
§150(e): installation ofFimplaccs, Decorative Gas Appliances and Gas Logs.
1. Masonry and fsctory-buh7t fireplaces have:
a. Closable metal or glass door
b. Outside air intake with damper and control
e. Flue damper and control
2. No continuous burning gas pilot lights allowed.
Space Conditioning, Water Heating and Plumbing System Measures:
HVAC cquipmcro, orator heaters, showerheads and teuects certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with A.SHRAE, SMACNA or ACOA.
§00(i); Setback thermostat oo all applicable hentiag and/or cooling systems.
§L506): Pipe and tank insulation
1. Storage gas water haters rated with an Energy Factor less than 0.59 must be exttmally wrapped with.
insulation having an installed thermal resistance of R-12 or grater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systema, insulated (R4 or greater)
3. Backup tanks for solar systcrn, untircd smsagc tanks, or other indirect hot water tanks have k-12 external
insulation or R-16 combined internaUtmemal insulation.
4. All buried or exposed piping insulated in recirculating scstions of hot water systems.
5. Calling systehn piping below 55" F insulated.
& Piping insulated between heating source and mditect hot water tank.
July 1, 1999
FROM F ChriStenSer✓T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:54AM PS
MANDATORY MEASURES CHECKLIST: RESIDENTIAL(page 2 of 2) MF -1R
Note: Lowrise residential buildings subject to the Standards must contain that mcmntres regardless of the compliance approach used.
Items marked with an asterisk (a) may be superseded by more stringent t ompliancc requirancttts listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents. the features rated shall be considered by all parties
as minimum component performance specifications for the mxndrwhry me "ores whether they are shown elsewhere in the
documents or on this checklist only.
Instructions: Check or Initial applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and plumbing System Measures: (continued)
• § 150(m): Ducts and Fans
I. All ducts and plenums constructed. itutalkd, iasulased, fastened, and sealed to comply with the 1CBO 1997
UMC sections 601 and 603; ducts inpdaied to a minimum installed R-41 or ducts enclosed entirely within
conditioned space. Openings shall be scaled with mastic, tape, aerosol sealant or other duct closure system
that meets the applicable requiremetas ofUL181, UL 191 A, or UL 18IB and other applicable specified
tests for longevity given in §Iwm)..
2. Exhaust fan systems have back dn8 or autonsatic dampcts.
3. Gravity ventilating systems serving conditioned space have tither automatic or readily accessible, manually
/
operated dampers.
§ 114: Pool and Spa Heating Systcau and Equipment.
1. System is crd&d with 78% thermal efficiency. un -off swiOL wtsihaproof operating
. instructions, no electric resistance beating Gad no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor poets or outdoor spas.
3. Pool system las directional inlets and a circulation pump time switch.
§ t IS: Gas find antral furnaces, pool beatats, spa heaters or bousebold cooking appliances have no
continuously burning pilot light. (Exce
rptioni Non -electrical cooking appliances with pilot < 150 Bturlhr
Lighting Measures:
§150(k)l.: Luminaires for getieral lighting in kitchens shall have lamps with an efficacy of40lumens/wan or
greater for general lighting in kitcheiu. This gatesl lighting shall be controlled by a switch on a readily
accessible lighting control panel at an entrance to the kitchen.
§ I Wk)2.: Rooms with a shower or bathtub must either have at lcaat one luminaire with lamp with an efficacy
of 40 lumenVwati or greater switched at the entrance to the room or one of the attematives to this requirement
allowed in j 150(k)2.: and recessed Ceiling fixtures arc IC insulation cover) (4pproved.
July 1, 1999
FROM :- Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:55AM P9
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title:..•.....•. Plan Taos 1696 Date. .01/04/00 10.1'7:52
Project Addre:ss........ *******
La Quinta,'Ca *v5.00*
Documentation; Author,.. Carole Christensen ******* Building Permit
Carole Christensen
47-596 Lake Canyon Drive Plan Check 7 Date
Aguanga, CA 92536
800-735-8152 FieTZ1 Che-ER7Date
Climate Zone. ..... 15
Compliance Me;thod...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc.
MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
GENERAL INFORMATION
Conditioned Floor Area..... 1696 sf
Building Type .............. Single Family Detached.
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type........... ReducedYear.
Floor Construction Type.... Slab On Grade
Number of Building Zones... 1
MICROPAS5
ENERGY USE SUMMARY
Energy
Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin.
Space
Heating..........
3.24
2.39
0.85
Space
Cooling..........
43.20
45.9
-2.73
Water
Heating..........
'14.50
13.06
1.44
North Total
60.94
61.38
-0.44
Space
Heating..........
3.24
2.37
0.87
Space
Cooling..........
43.20
44.76
-1.56
Water
Heating..........
14.50
13.06
1.44
East Total
60.94
60.19
0.75
Space
Heating..........
3.24
2.87
0.3.7
SpaCe
Cooling..........
43.20
45.16
-1.96
Water
Heating..........
14.50
13.06
1.44
South Total
60.94
61.09
-0.15
Space
Heating....
3.24
2.96
0.28
Space
Cooling..........
43.20
41.65
1.55
Water
Heating..........
14.50
13.06
1.44
West Total
60.94
57.67
3.27
**:* Building does not comply with
Computer Performance ***
GENERAL INFORMATION
Conditioned Floor Area..... 1696 sf
Building Type .............. Single Family Detached.
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type........... ReducedYear.
Floor Construction Type.... Slab On Grade
Number of Building Zones... 1
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:56AM P10
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title........... Plan Taos 1696 Date..01/04/00 10:17:52
MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
Zone Type
HOUSE
Residence
Conditioned Volume......... 16960 cf
Slab -Ori -Grade Area......... 1696 sf
Glazing Percentage......... 16.8 t of floor area
Average Glazing TJ -value .... 0.75 Btu/hr-sf-F
Average Glazing SHGC....... 0.69
Average Ceiling Height..... 10 ft
BUILDING ZONE INFORMATION
Floor
# of
Vent
Vent
Air
Area Volume
Dwell Cond- Thermostat
Height
Area
Leakage
(sf) (cf)
Units itioned Type
(ft)
(s£)
Credit
1696 16960
1.00 Yes Setback
2.0
Standard
No
Location/
Comments
To garage
Flat
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
HOUSE
9 S1abEdge 160
10 SlabEdge 28
orientation
HOUSE
1 Window Front (N)
2
Door
Front
(N)
OPAQUE
SURFACES
Front
(N)
4
Area
U-
Insul
Act
Solar
Form 3
Surface
(sf)
value
R-val
Azm
Tilt'Gains
Reference
HOUSE
(E)
8
Window'
Left
(E)
9
1
Wall
131
0.060
17.61
0
90 Yes
W13.2X4.16FA
2
Wall
459
0.060
17.61
90
90 Yes
W13.2X4.16FA
3
Wall
347
0.060
17.61
180
90 Yes
W13.2X4.16FA
4
Wall
392
0.060
17.61
270
90 Yes
W13.2X4.16FA
5
Wall
263
0.086
13
0
90 No
GARWALLR13
6
Door
20
0.330
0
270
90 No
None
7
Door
17
0.330
0
0
90 No
None
8
Roof
1684,
0.025
38
n/a
0 Yes
R.38.2X4.24
PERIMETER LOSSES
Location/
Comments
To garage
Flat
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
HOUSE
9 S1abEdge 160
10 SlabEdge 28
orientation
HOUSE
1 Window Front (N)
2
Door
Front
(N)
3
Window
Front
(N)
4
Window
Left
(E)
5
Window
Left
(E)
6
Window
Left
(E)
7
Door
Left
(E)
8
Window'
Left
(E)
9
Door
Back
(S)
10
Window
Back
(S)
0.760 R-0 No to outside
0.510 R-0 No To garage
FENESTRATION SURFACES
Area U- Act Exterior Shade Interior Shade
(sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC
6.0 0.630 0.720 0 90 Standard/0.76 Standard/0.68
33.3 0.850 0.700 0 90 Standard/0.76 Standard./0.68
10.0 0.630 0.720 0 90 Standard/0.76 Standard/0.68
25.0 0.720 0.670 90 90 Standard/0.76 Standard/0.68
9.0 0.720 0.670 90 90 Standard/0.76 Standard/0.68
30.0 0.720 0.670 90 90 Standard/0.76 Standard/0.68
33.3 0.850 0.700 90 90 Standard/0.76 5tandard/0.68
24.0 0.630 0.720 90 90 Standard/0.76 Standard/0.68
33.3 0.850 0.700 180 90 Standard/0.76 8tandard/0.68
10.0 0.630 0.720 180 90 Standard/0.76 Standard/0.68
FROM ChriStensen/T-24/CABEC FAX N0. : 909 763 0522 Jan. 04 2000 11:56AM P11
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:5.2
MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
Orientation
11 Window Back (S)
12 Window Right (W)
13 Window Right (W)
14 Window Right M
15 Window Right (W)
16 Skylight Horz
17 Skylight Horz
18 Skylight Horz
FENESTRATION SURFACES
Area U- Act Exterior Shade Interior Shade
(sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC
10.0 0.630 0.720 180 90 Standard/0.76 Standard/0.68
4.0 0.720 0.670 270 90 Standard/0.76 Standard/0.68
12.4 0.550 0.700 270 90 Standard/0.76 Standard/0.68
16.0 0.720 0.670 270 90 Standard/0.76 Standard/0.68
16.0 0.720 0.670 270 90 Standard/0:76 Standard/0.68
4.0 0.940 0.730 0 0 None/1 None/1
4.0 0.940 0.730 0 0 None/1 None/1
4.0 0.940 0.730 0 0 None/1 None/1
OVERHANGS AND SIDE FINS
Window--- ---Overhang Left Fin Right Fin -
Area Left Rght
Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
HOUSE
1 Window 6.0 2.0 3.0 4.0 0.5 0.5 0.5 0.5 4.0 0.5 0.5 4.0 0.5
SLAB SURFACES
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
Area
Slab Type (sf)
HOUSE
Standard Slab 169.6
HVAC SYSTEMS
Minimum Duct Duct Tested Duct ACCA
Duct
System Type
Efficiency Location R -value Leakage
Manual
D Eff
HOUSE
Furnace
0.800 AFUE Attic R-4.2 No
No
0.743
ACSplit
12.00 SEER Attic R-4.2 No
No
0.596
WATER HEATING SYSTEMS
Number
Tank
External
in Energy
Size
Insulation
Tank Type
Heater Type Distribution Type System Factor
(gal)
R. -value
1 Storage
Gas Standard 1 0.58
50
R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
***
Items in this section should be documented on the
plans,
***
***
installcd to manufacturer and CEC specifications,
and
***
***
verified during plan check and field inspection.
***
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
FROM :` Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:57AM P12
COMPUTER METHOD SUMMARY Page 4 C -2R
Project Title.......... Plan Taos 1696 Date..01/04/00 10:17:52
MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
REMARKS
Philips Fenestration or better
FROM ' Christensen/T-24/CASEC FAX NO. : 909 763 0522 Jan. 04 2000 11:57AM P13
CONSTRUCTION ASSEMBLY Page 1 3R
Project Title.......... Plan Taos 1696 Date. .'01/04/00 10:17:52
MI'CROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
Parallel Path Method
Reference Name . W13.2X4.16FA
Description .... WallR-13 2x4 16oclinFalc
Type ........... Wall
R -Value ........ 17.61 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4.
Type ......... Wood
Description .. 2x4 fir
Spacing 16 inches on center
Framing Frac.. 0.15
'Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Total R -Value: 1 / 0.060 = 16.66 hr-sf-F/Btu
Material
Cavity
Frame
Name
Description
R -Value
R -Value
O.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
STUCC0.0.88
0..875 in stucco
0.17
0.17
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
R 4.61 RIGID
R-4.61 Insulated Sheathing
4.61
4.61
4c.
BATT.R13
R-13 batt insul (cavity = 3.5 in)
13.00
--
4f.
FIR.2X4
2x4 fir
--
3.46
5.
GYP.0.50
0.50 in.gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL .Inside
air film: heat sideways
0.68
0.68
Total Unadjusted R -Values 19.15
9.61
FRAMING
ADJUSTMENT
CALCULATION
Cavity Framing
Total
U -Value:
(1 / 19.15
x 0.85) + (1 / 9.61 x 0.15)
0.060 Btu/hr-ef-F
Total R -Value: 1 / 0.060 = 16.66 hr-sf-F/Btu
FROM : Christensen/T-24/CABEC FAX NO. : 909763 0522 Jan. 04 2000 11:59AM P14
CONSTRUCTION ASSEMBLY Page 2 3R
Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:52
MICROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
Parallel•Path Method
Reference Name . GARWALLRI3
Description .... Wall R711 2x4 16oc
Type ........... Wall
R -Value ........ 13 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type ......... Wood
Description .. 2x4 fir
Spacing ...... 16 inches on center
Framing Frac.. 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
FRAMING ADJUSTMENT CALCULATION
. Cavity
Total Unadjusted R -Values
Framing
U -Value: (1 / 14.81 x 0.85) + (1 / 5.27 x 0.15) =
Cavity
Material
R -Value
R -Value
0.17
Name
Description
0.45
0.
FILM.EX
Exterior air film: winter
value
1.
GYP.0.50
0.50 in gypsum or plaster
board
2.
BLDG.PAPER
Building paper (felt)
3t.
BATT.R13
R-13 batt insul (cavity =
3.5 in)
3f.
FIR.2X4
2x4 fir
4.
GYP.0.50
0.50 in gypsum or plaster
board
I.
FILM.IN.WLL
Inside air film: heat sideways
FRAMING ADJUSTMENT CALCULATION
. Cavity
Total Unadjusted R -Values
Framing
U -Value: (1 / 14.81 x 0.85) + (1 / 5.27 x 0.15) =
Cavity
Frame
R -Value
R -Value
0.17
0.17
0.45
0.45
0.'06
0.06
13.00
--
--
3.46
0.45
0.45
0.68
0.68
14.81 5.27
Total
0.086 Btu/hr-sf-F
Total R -Value: 1 / 0.086 11.6.5 hr-sf-F/Btu
FROM ; Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:59AM P15
CONSTRUCTION ASSEMBLY Page 3 3R
Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:52
MICROPAS5 v5.00 File-TAOS1696 Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
Parallel Path Method
Reference Name . R.38.2X4.24
Description .... Roof R-38 2x4 24oc
Type ........... Roof
R -Value ........ 38 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type wood
Description 2x4 fir
Spacing ...... 24 inches on center
Framing Frac.. 0.07
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
U -Value: (1 / 40.92 x 0.93) + (1 / 33.39 x 0.07.) = 0.025 Btu/hr-sf-F
Total R -Value: 1 / 0.025 = 40.28 hr-sf-F/Btu
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0..17
0.17
1.
SHNGL.CEMENT
Asphalt -cement shingles
0.21
0.21
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
PLY.0.50
0.50 in plywood
0.62
0.62
4.
ATR.RF.3.50
3.5 in & greater air space: heat flow up
0.80
0.80
5.
BATT.R27.0
R-27 batt insulation
27.00
27.00
6c.
BATT.RII.0
R -1i batt insul (cavity > 3.5 in)
11.00
--
6f..
FIR. 2X4
2x4 fir
--
3.46
7.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.RF
Inside air film: heat flow straight up
0.61
0.61
Total Unadjusted R -Values
40.92
33.39
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
U -Value: (1 / 40.92 x 0.93) + (1 / 33.39 x 0.07.) = 0.025 Btu/hr-sf-F
Total R -Value: 1 / 0.025 = 40.28 hr-sf-F/Btu
.FROM Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 11:59AM P16
HVAC SIZING Page 1 HVAC
Project Title.......... Plan Taos 1696 Date -01/04/00 10:17:52
Project Address........ *******
La Quinta,, Ca *v5.00*
Documentation Author... Carole Christensen ******* Building Permit
Carole Christensen
47-596 Lake Canyon Drive an Check ate
Aguanga, CA 92536
800-735-8152 Field Che—c— Date
Climate Zone.... ..... 15
Compliance Method...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc.
MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
GENERAL INFORMATION
Floor Area .................
Volume .....................
Front Orientation..........
Sizing Location............
Latitude... .... ........
Winter Outside Design......
Winter Inside Design,.....
Summer Outside Design......
Summer Inside Design.......
Summer Range........ .....
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
Description
1696 sf
16960 cf
Front Facing 0 deg (N)
PALM DESERT
33.7 degrees
32 F
70 F
112 F
78 F
34 F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating
(Btuh)
Opaque Conduction and Solar...... 11101
Glazing Conduction ............... 8091
Glazing Solar .................... n/a
Infiltration ..................... 8956
Internal Gain .................... n/a
Ducts ............................ 2815
Sensible Load .................... 30962
Latent Load....... ............... n/a
Minimum Total Load 30962
Cooling
(Btuh)
5647
7239
13777
5927
2550
3514
38654
7731
46385
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
,FROM Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 12:00PM P17
HVAC SIZING Page 2 HVAC
Project Title.......... Plan Taos 1696 Date..01/04/00 10:17:52
MICROPAS5 x5.00 File-TAOS1696 Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
GENERAL INFORMATION
Floor Area .................
1696
sf
Volume.....................16960
cf
Front Orientation..........
Front
Facing
Sizing Location............
PALM
DESERT.
Latitude... ..... ........
33.7
degrees
Winter Outside Design......
32 F
Winter Inside Design.......
70 F
Summer Outside Design......
112 F
Summer Inside Design.......
78 F
Summer Range...............
34 F
Interior Shading Used......
No
Exterior Shading -Used ......
No
Overhang Shading. Used......
No
Latent Load Fraction.......
0.20
HEATING AND COOLING .LOAD SUMMARY
Heating
Description (Btuh)
Opaque Conduction and Solar...... 11101
Glazing Conduction ............... 8091
Glazing Solar .......... ........... n/a
Infiltration ..................... 8956
Internal Gain .................... n/a
Ducts ............................ 2815
Sensible Load .................... 30962
Latent Load..'. ................... n/a
Minimum Total Load 30962
90 deg (E)
Cooling
(Btuh)
5647
7239
11680
5927
2550
3304
36347
7269
43617
Note: The loads shown,are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc.., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Jan. 04 2000 12:00PM P18
HVAC SIZING Page 3 HVAC
Project Title........... Plan Taos 1696 Date..01/.04/00 10:17:52
MICROPASS v5.00 File-TAOS1696 Wth-CTZ15S92 Program -HVAC SIZING
User#-MP.1017 User -Carole Christensen Run-VbF80.10.R13Falc38.4EF60
GENERAL INFORMATION
Floor Area ................. 1696 sf
Volume..: .... *............
16960 cf
Front Orientation..........
Front Facing
Sizing Location............
PALM DESERT
Latitude... .... ........
33.7 degrees
Winter Outside Design......
32 F
Winter Inside Design.......
70 F
Summer Outside Design......
112 F
Summer Inside Design........
78 F
Summer Range ...............
34 F
Interior Shading Used......
No
Exterior Shading Used......
No
Overhang Shading Used......
No
Latent Load Fraction........
0.20
Description
HEATING AND COOLING LOAD SUMMARY
Heating
(Btuh)
Opaque Conduction and Solar...... 11101
Glazing Conduction ............... 8091
Glazing Solar..................... n/a
Infiltration ..................... 8956
Internal Gain .................... n/a
Ducts .................. I......... 2815
Sensible Load .................... 30962
Latent Load ...................... n/a
180 deg (S)
Cooling
(Btuh)
5647
7239
13719
5927
2550
3508
38590
7718
Minimum Total Load 30962 46308.
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered., It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
„FROM Christensen/T-24/CAHEC FAX NO. : 909 763 0522 Jan. 04 2000 12:01PM P19
HVAC SIZING Page 4 HVAC
Project Title.......... Plan Taos 1696 Date. .01/04/00 10:17:52
MICROPAS5 v5.00 File-TAOS16.96 Wth-CTZ15S92 Program -HVAC SIZING
User4-MP1017 User -Carole Christensen Ruh-VbF80.10.R13Falc38.4EF60
GENERAL INFORMATION
Floor Area ..................
volume .....................
Front Orientation..........
Sizing Location.............
Latitude... .............
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range........ .....
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
1696 s£
16960 cf
Front Facing 270 deg (W)
PALM DESERT
33.7 degrees
32 F
70 F
112 F
78 F
34 F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating Cooling
Description (Stuh) (Etuh)
Opaque Conduction and Solar......
11101
5647
Glazing Conduction ...............
8091
7239
Glazing Solar ....................
n/a
10653
Infiltration .....................
8956
5927
Internal Gain ....................
n/a
2550
Ducts ............................
2815
3202
Sensible Load ....................
Latent Load ......................
30.962
n/a
35217
7043
Minimum Total Load 30962 42261
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
FROM ChristenSen/T-24/CABEC FAX NO. 909 763 0522 Jan. 04 2000 12:01PM P20
' v"' ' ',•U44 DLSMI w1NLUQW.5 PA& 67
08�OIr'6p 11.12 FAT 2IS2000016 X904CIUSupporc
®ooZ
PNI
1:1�M
7.99
U0 Al
W'n V
U2" S u.
24011S 110riz0atti SUder Cicar/Air/C1ear .72
Clear/Ar;on/Clou .70
Cktr/i,owE/Our .57
Clr/LowE/Arg/Clr .53
Z405H
240F
SintIt Hung
Clear/Air/Clctr .72
Ctetr/Argon/Clear .70
Clenr/LOw-VCleai .57
Or/LowE/Ar^g/Cir 13
.67
W/ Grids .61
.67
W/ Grids .61
.38
w/ Grids .35
.3b
wt Grids .35
.6;
w/ Grids .61
.65
w/ Grids .61
.38
w/ Grids .35
.S8
w/ Gads .3;
Picture Window Citar/Air/Clear .63 .72
wt Grids .66
Cleor/Argoa/Cltsr .60 72
w/ Grids .66
Clctr/LowFlCkir .43 . .40
w/ Grids .37 .
C(r/LowEJA,rgfClr .41 .40
W/ Grids .3'
Philips Products uses Spectrally Sclec&t Lo+wE Cum`ings