Loading...
9604-031 (SFD) Title 24i TITLE 24 REPORT FOR: a' BELNAP CONSTRUCTION EISHENHOWER, LA QUINTA 1410 S9.FT:/N_ORTH FACE PROJECT DESIGNER: BELNAP CONSTRUCTION REPORT PREPARED BY: GINA TROOLINES MJT Construction Services 4277 Main St. Riverside, Calif. 92501--3822 ( 909 ) 369-1700 Job Number: 5364-1 Date= 11/26/1995 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This program has.approval arid is authorized by the California Energy Commission for- use with both the Residential and Nonresidential.Bui.lding Energy Efficiency Standards. TLh; nrr.riram .-J�­1l r,aA by (Zmk� I n^rA i_N on ; atcc ( r,1 n ) A -->s -05: nO q Table Of Contents for Title 24 Report CoverPage .......................................................: 1 Table .of Contents .............................. .................... 2 Form CF --1P, Certificate of.Compliance: Residential ................... 3 Form MF -1R Mandatory Measures Checklist: Residential ................ S Form P -2R Point System Summary .... ................................. 7 HVAC Zone & Space Loads Summary ..................................... a. :-ERTIFICATE OF COMPLIANCE. Residential (part. 1 of 2) CF -1R Page 3 of 10 --------------------------------------------------------------------------- lroject Name:.BELNAP CONSTRUCTION oDate: 11i26/1995 Address: EISHENHOWER, LA QUINTA o 1410 SQ.FT./NORTH FACE 6Building Permit No 6 Designer: BELNAP' CONSTRUCTION 6Checked by / Date 6 Docume-ntation: MJT Construction Services .6COMPLY 24 User 1160 ------------------------------------------------------------------------------ GENERAL INFORMATION Compliance Method: Climate -Zone= Conditioned Floor- Area: Building Type: Building Front Orientation: Number of Dwelling Units: Floor Construction Type: BUILDING SHELL INSULATION Component ------------------------ R-15 -------------------- R-15 Wall w/1" EPS R-38 Roof(R .38 .2x14.16 ) Slab Perimeter w/R-0.0 Slab Perimeter w/R-0.0 FENESTRATION Orient. Area U -Val Type --------- Front ( N ) ------ S1.5 ----- 0.55 ------ Double Front ON) 31.0 0.55 Double Left (E) 6.0 0.55 Double Left (E) S6.0 0.55 Double Back (S) 37.3' 0.55 Double Right ( W ) 9.0 0.55 Double Right ( W ) 48.0 0.55 Double Right ( W ) 40.0 0.6s Double Skylight 16..0 0.80 Double THERMAL MASS Type ---------------------- Concrete, Heavyweight Concrete, Heavyweight Tile in Mortar COMPLY 24 version 4.10 1S .1410 sqft Single Fam Det 0 deg ( N ) 1 Slab on Grade U -Value Location/Comments ------- ------------------------------------ 0.065 WHOLE HOUSE. 0.028 WHOLE HOUSE 0.900 WHOLE HOUSE 0.720 WHOLE. HOUSE Shading Devices 4 Frame OH Interior Exterior N N ---------------- Std DrapeStandard --------------- Bug Scr Std Drape Standard Bug Scr Std Drape Standard Bug Scr Light Blind Standard Bug Scr Light Blind Standard Bug Scr Std Drape Standard Bug Scr Light Blind Standard Bug Scr Std.Drape. Standard Bug Scr none none - Area Thick Covering (sf ) (in) Exposed 980 3.50 Covered 430 3.50 Exposed 58 1.50 Location/Description- ----------- ocation/Description Slab on Grade Slab on Grade WHOLE HOUSE/Int Mass 4 Frame OH SF Type N N Vinyl Y N Vinyl Y N Vinyl N N Vinyl N N.Vinyl Y N Metal N N ViTryl Y N Wood N N Metal . Location/Description- ----------- ocation/Description Slab on Grade Slab on Grade WHOLE HOUSE/Int Mass I 'k 0 CERTIFICATE OF COMPLIANCE: Residential (part 2 of 2) CF" -1R page 4 of 10 Project Name. BELNAP CONSTRUCTION 6Date: 11/26/1995 6 Documentation: MJT Construction Services 6COMPLY 24 User 1160 ---------------------- =------ ------------------------=--------------------- HVAC SYSTEMS Minimum Distrib Type Duct TStat `yst.em.Type Efficiency and Location RVal Type Location/Comments -------------------------------------- ---- ------ ----------------------- Furnace 0.785 AFUE Ducts in Attic 4.2 SetBck WHOLE HOUSE Sp1t.AirCond12.000 SEER Ducts in Attic 4.2 SetBck Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution Type Type Sys Factor (gal) R• -Val AMERCIAN/OR EQUAL Standard StorGas 1 0.62 50.0 0-0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light AMERCIAN/OR EQUAL DomesticHW 0.790 50000 0.032 16.0 01, SPECIAL FEATURES/REMARKS COMPLIANCE STATEMENT This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 & 6 of the Califor- r,ia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed.by the individual with overall . design responsibility. When this certificate of compliance is submitted for a.single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section DESIGNER or OWNER ( Per Business &Professions Code) BELNAP CONSTRUCTION Lic #: (signature) (date) ENFORCEMENT AGENCY Name: Titie: Agancy:_ Telephone: DOCUMENTATION AUTHOR GINA TROOLINES MJT Construction Services 4277 Main St. Riverside, Calif. 92501-3822 (90 69-170 ( signat re ) (date) (signature/stamp) ( date ) MANDATORY MEASURES C.'HECKLIST ( part 1. of 2; MF -1R page 5 of 10 Project Name: BELNAP CONSTRUCTION . .6Date: 11;/26/1995 _ o Documentation: MJT Construction Services- 6COMPLY 24 User 1160 --------------------------------------------------------------------------- NO TE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements lisr_ed on the Certificate of Compliance. When.this checklist is incorporated into the permit documents, the features noted shall be considered.by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES o Sec. 150(a): Minimum R-19 ceiling insulation. o Sec. 1SO(b): Loose fill insulation manufacturers labeled R -Value. o Sec. 150(c): Minimum R-13 wall insulation in.framed walls (does not apply to exterior mass walls).* o Sec. 150(d): Minimum R-13 raised floor insulation in framed floors; Minimum R-8 in concrete raised floors. * o Sec. 150(1): Slab edge insulation —water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. o Sec. 118: Insulation specified.or installed meets California Energy Commission quality standards. Indicate Type & form. o Sec. e. b. c.. Enforcement 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. Manufactured fenestration products have label w/certified U -Value Exterior doors and windows weatherstripped;.all joints and -penetrations caulked and sealed.. __ o Sec. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16• only. o Sec. 1SO(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. o Sec...15O(e)': Installation of Fireplaces, Decorative Gas Appliances.and Gas Logs 1. Mlasonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control ?. No continuous burning gas pilots allowed. 'A. MA=NDATORY MEASURES CHECKLIST (part 2 of -2) MF -1R page 6 of 10 --------------------------------------------------------------------------- Project Name: BELNAP CONSTRUCTION 6Date: 11/26/1995 Documentation: MJT Construction Services 6COMPLY 24 User 1160 --------------------------------------------------------------------------- SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement o Sec. 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. _ o Sec. 150(i): Setback thermostat on all applicable heating systems. o • Sec. 1 o Sec. 1. 2. 3. 150(j): Pipe and Tank Insulation Indirect hot water tanks (eg unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16.or greater). First 5 feet of pipes closest to water heater tank, non -recirculation systems, insulated (R-4 or greater. All buried or exposed piping insulated in recircula.tio.n sections of hot water system. Cooling system piping below 55 F insulated. Piping insulated between heating source and indirect hot water tank. _ 15,0(m) Ducts and Fans * Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated -to a minimum R-4.2 or ducts.enclosed entirely within conditioned space.. Exhaust systems have backdraft or automatic dampers. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers. _ o Sec. 114:Pool and Spa Heating Systems and Equipment 1. System is certified with 78m thermal efficiency, on-off switch, weatherproof oper.ating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a..At least-.3&pipe between filter and heater for future solar heati.ng":,- 'b. Cover, for outdoor pools or outdoor spas 3. Pool system has directional inlets and a circulation pump time switch. o Sec. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light. (Exception: Non -electrical cooking . appliance with pilot < 150 Btuh) LIGHTING - MEASURES o Sec. 150(k): Lighting.- 40 lumens/watt or greater for general lighting in kitchens•and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. F-,�, I POINT SYSTEM SUMMARY P -2R cage 7 of 10 Project. Name= BEL -NAP CONSTRUCTION 6Date= 11/26/1995 0 Documentation: MJT Construction Services .6COMPLY 24 User 1160 BUILDING DATA Conditioned Floor area 1410 sgft Number of Stories '1 .Occupancy Type Single Fam Det 5.9 x SCORE CARD Measure 0.86 -1 1. Roof Insulation ------- 0 .02.83 (U -Value) 0.67 = 2. Wall Insulation 0.0645 (U -Value) . 37 .3 3. Raised Floor Insulation 0.0000 (U -Value) o 1 West 97.0 6.9 6 3a. Controlled Vent Crawlspace 0.0 (R -Value) o-> 16.0 1.1 x 0.79 = 6 4. Slab Edge Insulation 0.7946 (f2 factor) -6 S. Infiltration Standard 6. Glass Heat Loss .0.56 20.9% 7. Fenestration Heat Gain SC Orientation Area % Glass Open Eff % SER Points .0 North 82.5 5.9 x 0.68 _ 4.0 0.86 -1 East 62.0 4.4 x 0.67 = 2.9 0.65 -2 South- . 37 .3 2-6-- x 0.68 = 1.8 0.64 1 West 97.0 6.9 x 0.60 4.1 0.71 -5 Skylight 16.0 1.1 x 0.79 = 0.9 1.00 -5 8. Interior.Thermal Mass 3.84 9. Exterior Wall Mass 0.00 10. Heating System Zonal Control: No '11. Cooling System 12. Water Heating Point Total -2 0 -2 Sum 1-6? 9 0 Sum 7-9 -5 -7 0 9 3 0 HVAC =ONE HEATING & COOLING LOAD SUMMARY page 8 of 10 Project Name: BELNAP CONSTRUCT ION 6Date: 11/26/1995 _ o Documentation: MJT Construction Services 6COMPLY 24 User 1160 HVAC ZONE DESCRIPTION HVAC Zone Name: Heating System Name: Cooling System Name: System Multiplier: Fan Schedule: Peak Load Method: Relative Humidity: WHOLE HOUSE Day&Night 398BAZO42071 Day&Night 597BNO42-A 1 Day Fans STD NONCOINCT_DENT 50 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible arid Latent Cooling Loads -are indicated to allow for accurate comparison with manufacturer's output data. COOLING SPACES IN THIS ZONE PEAK HEATING PEAK SENSIBLE LATENT ----------------------- WHOLE ---- HOUSE (Jan 12am) ------- 31.507 ------------ (Aug 2pm) 30855 ------ 858 TOTAL SPACE LOAD 31507 30855 858 Duct Gains & Losses: 3151 3086 - Return Air Lighting Gain ------- 0 -------- ---TOTAL - TOTAL SYSTEM LOAD 34658 33941 858 SYSTEM OUTPUT AT DESIGN CONDITIONS 71000 27216 9967 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible arid Latent Cooling Loads -are indicated to allow for accurate comparison with manufacturer's output data. l - RESIDENTIAL ;PACE HEATING LOAD SUMMARY page 9 of 10. Project Name: BELNAP CONSTRUCTION 6Date: 11/26/1995 Documentation: MJT Construction Services 6COMPLY 24 User 1160 Space Name= WHOLE HOUSE Design Indoor Dry Bulb Temperature: 70 F Design Outdoor Winter Dry Bulb Temperature: 29 F Design Temperature Difference: 41 F Conduction R-15 Wall w/1" EPS Double Clear (NR Std) Double Clear (Res Std) .R-38 Roof(R.38.2x14.16) Double Clear ( Res Dflt ) Slab on Grade Slab on Grade Infiltration: 1.00 x' 0.018 x Ventilation:, 1.080 x TOTAL HOURLY HEAT. LOSS FOR SPACE 'x1507 Heating AirFlow: 31507 Btu/hr / A1.08 x 35 F DeltaT)O = 834 cfm Area U -Value TD Btu/hr 1865.2 x 0.0645 x 41.0 - 4933 238.8. x 0.5500 x 41.0 = 5385 40.0 -x 0.6500 x-41.0 = 1066 1394.0 x 0.0283 x 41.0 = 1620. 16.0..x 0.8000 x 41.0. = 525 Perim = 63.0- x 43. = 2709 Perim = 89.0 x 43 = :.3827 1410 sf x 11.0 ft x 1.00 AC x 41.0.'.=':; 11442 1410 sf x 0.0 cfm / 333.0 x 41.0 ==- 0 TOTAL HOURLY HEAT. LOSS FOR SPACE 'x1507 Heating AirFlow: 31507 Btu/hr / A1.08 x 35 F DeltaT)O = 834 cfm J r` F:E',:';IDF-NTIAL =•PACS CC-OLING LOAD SUMMARY page iO of 10 ---------------------- * Name: BELNAP CONSTRUCTION 6Date: 11/26/1995 o Documentation: ----------------------------------- MJT Construction Services 6COMPLY 24 User 1160 ,pace Name: WHOLE HOUSE Design Indoor Dry Bulb Temperature: 78 F Design Outdoor Summer Dry Bu1b'Temperatu.re: 112 F Design Temperature Difference- 34 F Conduction Area U-Value DETD Btu/hr ----------------------- R.-15 Wall w/1" .EPS ------ 1865.2 x ------- 0.0645 x ----- 29.h ----- 31562 Double Clear (NR Std) 238.8 x 0.5500 x 34.0 - 446 Double Clear (Res Std)- ' 40.0- x 0.6500 x 34 .0 . = 884 R-38 Roof(R.38.2x14.16) 1394.0 x 0.0283 x 50.0 = 1976 Double Clear (Res Dflt) 48.0 x 0.8000 x 34.0 = 1306 Infiltration: 1.00,x 0.018 x 1410 sf x 11.0 ft x 1.00 AC x 34.0 = 9488 Ventilation: 1.080.x 1410 sf x 0.0 cfm:/ 333.0 x 34.0 = 0 Shaded Unshaded So:lar Gain Orient. Area SGF Area SGF Sc ---------=-------------- Double Clear (NR --------- Std) North A ---- --- 0.0 x 15 + ---- --- 51.5 x 150 ---- is 0.59 = 452 Double Clear (NR Std) North A 0.0 x 15 + 31.0 x 150 x 0.59 = : 272 Double Clear (NR Std) South A .0.0 x 15'+ 37.3 x 320 x 0.44 = 520 Double Clear (NR Std) West A 0.0 x 15 + 48.0 x 730 x 0.44 = 1526 Double Clear (NR Std) East A 22.4 x.15 + 33.6 x 730 x 0.44 = 1214 Double Clear (NR Std) East A 3.3 x 15 + 2.7 x 730 x 0.S9 = 143 Double Clear (NR Std)-West A 5.9 x 15 + 3.1 x 730 x 0.66 = 209 Double Clear (Res Std) West A 22.3 x 15 + 17.7 x 730 x 0.56 = 905 Double Clear (Res Dflt) Skylight A 0.0 x 1S + 16.0 x1520 x 0.79 = 1926 Internal Gain --------------------- Op-Frac. ---------- Area ------ Heat --------- Gain Conv. ----- Lighting 1.00 x 1410.0 x 0.200 x 3.413 = 962 Equipment" 1.00.. x 1410.0 x 0.100 x 3.413 = .481 Occupants .1.00 x 1410.0 x 225 / 333 = 953 TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE 308SS Latent Gain Op Frac. Area Heat --------- Gain Conv. ----- Btu/hr ------ ----------------------- Equipment -------- 1.00 x ------ 1410.0 x 0.000 x 3.413 = 0 Occupants 1.00 x 1410.0. x 225 / 333 = 953 Infiltration: 1.00 x 0.018 x 1410 sf x 11.0 ft x 1.00 AC x -0.3 = ---87 Ventilation: 1.080 x 1410 sf x 0.0 cfm / 333.0 x --0.3 - -0 TOTAL HOURLY LATENT HEAT GAIN FOR SPACE 858 Cooling AirFlow: 30855 Btu/hr / A1.08 x 23 F DeltaT)O = 1243 cfm