Loading...
Mountain View Country Club Villas TR 30357 (Plans C-1 & C-2) Title 24TITLE 24 REPORT t Title 24 Report for: o Mountain View Count 'Club 2 rY Q Q Plan C-1 & C-2 La-Quinta; C—A Project Designer: Toll Architecture 8.901 E. Mountain View, Suite 210 _ Scottsdale, AZ 85258 480-367-8307 { Repo rt,,Prepared By: 'Joan, D. Hacker Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234, r - - (760) 324=0216 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. -- APPROVED ;FOR CONST�TIDate:�� DA4 / S �%�By . . ' 4/4/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is '% authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By-EnergySoft Job Number: User Number: 2655 EnergyPro 3.1 ` By EnergySoft, Job Number: User Number: 2655 Certificate of Compliance: Residential (Part 1 of 2) CF-1 R Mountain View Country Club 4/4/2005 Project Title Date Plan C-1 & C-2 La Quinta Project Address Building Permit # Insu-Form Inc. (760) 324-0216 Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check/ Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,946 f? Total Conditioned Slab Area: 2,252 ft2 Building Type: (check one or more) Average Ceiling Height: 10.0 ft ❑ Single Family Detached ❑ Addition X❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Number of Dwelling Units: 1.00 Number of Stories: 2 Floor Construction Type: ® Slab Floor Component Type Frame . Type Const. Assembly U-Value Slab On Grade n/a 0.756 R-19 with 1 ° Power Wall _ Wood 0.045 Solid Wood Door None 0.387 R-1 3 Floor (F.1 3.2x6.16) Wood 0.067 R-38 Roof (R.38.2x14.16) Wood 0.028 FENESTRATION ® Raised Floor Location/Comments 6Lic, garage, typical, etc.) Covered Slab w/R-0.0 Perimeter Insulation Exterior Wall f Exterior Door Exterior Floor / Over Open Space Exterior Roof Sharfinn fipvirpc Type Orientation Area Fenestration Exterior Overhang Side Fins SF U-Factor SHGC Shading Yes / No Yes / No Front 67.5 0.39 0.35 Bug Screen X❑ ❑ ❑ X❑ Left 376.8 0.39 0.35 Bug Screen X❑ ❑ ❑ X❑ Left 3.8 0.35 0.37 Bug Screen x❑ ❑ ❑ x❑ Rear 230.0 0.39 0.35 Bug Screen ❑x ❑ ❑ x❑ Rear 84.0 0.35 0.37 Bug Screen 0 ❑ ❑ 0 Right 80.9 0.39 0.35 Bug Screen x❑ ❑ ❑. ❑x Front 2.3 0.35 0.37 Bug Screen x❑ ❑ ❑ ❑x ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 04/04/05 10:31:34 Run Code: 1112635894 EnergyPro 3.1 By Energ ySoft User Number. 2655 Job Number. Pa e:3 of 14 Certificate of Compliance:. Residential (Part 2 of 2)' - CF-1 R Mountain View Country Club 4/4/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution r Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Pipingg Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R-Vafue Type Comments rpntral Fumarp 80% AFUE Ducts in Attic 49 Setback C-1 ; Central Furnace 80% AFUE Ducts in Attir. 49 Sethack C-2 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R-Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Spthar-k r-1 Split Air Conditioner 12 0 SEER Ducts in Attic 49 'Spthnr-k r-9 WATER HEATING SYSTEMS Rated 1 Tank Energy Fact1 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery. Standby Tank Insul: System Name 'Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R-Value A O SMITH PGCG-50-226 Small Gas Standard 40,000 50 0.62 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS' ' This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the'administrative regulations to implement them. This certificate has been signed by the individual with' overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Joan D. Hacker Title/Firm: Toll Architecture Title/Firm: Insu-Form Inc. Address: 8901 E. Mountain View, Suite 210 Address: 68255 Corta Road Scottsdale, AZ 85258 Cathedral City, CA 92234 Telephone: 480-367-8307 Telephone: (760) 824-0216 Lic. #: Kdt,S(signature) (date) (sign lure) Enforc ent Agency Name: Title/Firm: Address: Telephone: . ItnergyPro 11 By EnergySoft User Number. 2655 Job Number. Page:4 of 14 f 'Mandatory Measures Checklist: Residential (Page 1 of 2) MFA R NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an + asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter WA if not applicable. DESIGNER ENFORCEMENT Building •Envelope Measures + ❑X '§ 150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R-Value. f § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-value in metal frame walls (does ❑X not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. i ❑§ 150(1): Slab edge insulation -water absorption rate no greater than 0.3%; water vapor transmission rate no greater than 2.0 permhnch: a§ 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doois and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. h + ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control > ' 2. No continuous burning gas pilots allowed. ' Space Conditioning, Water Heating and Plumbing System Measures ❑X § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. ' § 150(i):, Setback thermostat on all applicable heating and/or cooling systems. + ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All bused or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. r EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:5 of 14 Mandatory Measures Checklist: Residential ..(Page 2 of 2) MF-1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER S ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ' X] I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CIVIC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in ' r conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181 A, or UL181 B. If mastic or tape is used to seal openings r greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not . be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. , 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support plafforms may contain ducts. Ducts installed in cavities and support platforms shall not be ` compressed to cause reductions in the cross -sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. • 4. Exhaust fan systems have back draft or automatic dampers. s 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible," manually operated dampers. } 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, ' equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by'aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. M ❑ § 114: Pool and Spa Heating Systems and Equipment ` 1. Certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between fitter and heater for future solar, cover for outdoor pools or - spas. T a. At least 36" of pipe between fitter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. FRI§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. a§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/waft or greater switched at the entrance to the room or one of the alternative to this requirement i allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 .'By EnergySoft User Number. 2655 Job Number: Page:6 of 14 Computer Method Summary (Part 1 of 3) C-2R Mountain View Country Club 4/4/2005 Project Title Date Plan C-1 & C-2 La Quinta Project Address Building Permit # Insu-Form Inc. (760) 324-0216 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 2.91 Facing North Margin Facing East Margin Facing South' Margin Facing West Margin 2.79 0.12 2.87 0.04 3.38 -0.47 3.36 -0.45 Space Cooling 29.68 29.45 0.23 28.88 0.80 28.28 1.40 28.73 0.95 Domestic Hot Water 5:76 6.10 -0.34 6.10 -0.34 6.10 -0.34 6.10 -0.34 38.34 0.01 37.84 0.51 37.75 1 38.19 0.16 Totals 38.35 This C-2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 4,946 ft2 Building Type: Single Fam Attached Floor Construction Type: ❑X Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 17.1 Number of Dwelling Units: 1.00 Total Conditioned Volume: 49,460 ft 3 Number of Stories: 2 Total Conditioned Slab Area: 2,252 ft 2 BUILDING ZONE INFORMATION - # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area C-1 259 29 52n5�n 046 Conditioned Setback 8 nLa r-2 P a9aaaa 26 aan _p 5_4 Condifinned Setback 8 -n/a OPAQUE SURFACES Solar Act. Gains Type Area U-Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Wall 841 0.045 0 go ® R-19 with 1" Pnwar Wall C -1 nnnr_ 24 0.387 0 go ®❑ snlid Wood noor 1'-1 Wall 216 n-045 AR qn ®❑ R-19 with 1° Power Wall C-1 Wall 243 0.045 180 90 ®❑ A-19 with 1 ° Pnwar Wall r_1 WRIT 504 0-045 270 90 EX El R-19 with 1" Pnwar Wall r:-1 Floor 2,694 0-067 -0 1 Rn ❑ ® _R-13 Finnr (F 13 2x6 16) r-2 Wall 795 0� .045 Q o Ex El �19 with 1 ° Power Wall r-2 Wall 303 0.045 gQ gQ ®❑ R-19 with 1° Pnwar Wall r-2 Wall 163 0-045 1R0 An ®❑ R-19 with 1° Power Wall S;_2 Wall 435 0-045 270 90 ®❑ R-1 9 withOwpr Wg11 S _2 Rnnf 2 fj94 0.028 270 _0 :1 R-38 Rnnf (R 38 2x14 16.) C-2 N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑o °❑a ❑❑❑ ❑❑ Run Initiation Time: 04/04/05 10:31:34 Run Code: 1112635894 3.1 By EnergySoft User Number: 2655 Page:7 of 14 Computer Method Summary (Part 2 of 3) C-2R Mountain View Country Club 4/4/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1 Window Front (North) 15.0 n_gao 0.35 0 90 Dual Pane Windows C-1 2 Window Left (East) 36.0 0.390 0.35 90 90 Dual Pane Windows C-1 3 Window Left (East) 3.8 0.350 0.37 90 90 Dual Pane Windows C-1 4 Window Left (East) 36.0 0.390 0.35 90 90 Dual Pane Windows C-1 5 Window Left (East) 54.0 0.390 0.35 90 90 Dual Pane Windows C-1 6 Window Left (East) 64.0 0.390 0.35 90 90 Dual Pane Windows C-1 L Window Rear (South) 64.0 0.390 0.35 180 90 Dual Pane Windows C-1 8 Window Rear (South) 36.0 0.390 0.35 180 90 Dual Pane Windows C-1 .9- Window Rear (South) 42.0 0.350 0.37 180 90 Dual Pane Windows C-1 1Q Window Rear (South) 15.0 0.390 0.35 180 90 Dual Pane Windows C-1 11 Window Right (West) 3.8 0.390 0.35 270 90 Dual Pane Windows C-1 12 Window Right (West) 18.0 0.390 0.35 270 90 Dual Pane Windows C-1 13_ Window Right(West) 3.8 0.390 0.35 270 90 Dual Pane Windows C-1 14 Window Front (North) 2.3 0.350 0.37 0 90 Dual Pane Windows C-2 15 Window Front (North) 15.0 0.390 0.35 0 90 Dual Pane Windows C-2 16 Window Front (North) 30.0 0.390 0.35 0 90 Dual Pane Windows C-2 17 Window Front (North) 7.5 0.390 0.35 0 90 Dual Pane Windows C-2 18 Window Left (East) 14.0 0.390 0.35 90 90 Dual Pane Windows C-2 _1a Window Left (East) 60.0 0.390 0.35 90 90 Dual Pane Windows C-2 20 Window Left (East) 3.8 0.390 0.35 90 90 Dual Pane Windows C-2 21 Window Left (East) 45.0 0.390 0.35 90 90 Dual Pane Windows C-2 2_?_ Window Left (East) 64.0 0.390 0.35 90 90 Dual Pane Windows C-2 23' Window Rear (South) 64.0 0.390 0.35 180 90 Dual Pane Windows C-2 24 Window Rear (South) 36.0 0.390 0.35 180 90 Dual Pane Windows C-2 25 Window Rear (South) 42.0 0.350 0.37 180 90 Dual Pane Windows C-2 26 Window Rear (South) 15.0 0.390 0.35 180 90 Dual Pane Windows C-2 27 Window Right (West) 24.0 0.390 0.35 270 90 Dual Pane Windows C-2 28 Window Right (West) 3.8 0.390 0.35 270 90 Dual Pane Windows . C-2 29 Window Right (West) 13.5 0.390 0.35 270 90 Dual Pane Windows C-2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REM. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 2 Buq Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 2.5 1.5 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 5 Buq Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 8.0 8.0 12.0 0. 2, 12.07 Bug Screen 0.76 8.0 8.0 12.0 0.1 12.0 . 12.0 8 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 9 Buq Screen 0.76 6.0 7.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 2.5 1.5 2.0 . 0.1 2.0 2.0 12 Bug Screen 0.76 6.0 . 1.5 10.0 0.1 10.0 10.0 13 Bug Screen 0.76 2.5 1.5 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 1.5 1.5 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 4.0 2.5 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 2.5 1.5 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 4.0 3.5 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 2.5 1.5 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 6.0 7.0 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 27 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 28 Bug Screen 0.76 2.5 1.5 2.0 0.1 2.0 2.0 29 Buq Screen 0.76 3.0 1.5 2.0 0.1 2.0 2.0 Run Initiation Time: 04/04/05 10.31.34 Run Code: 1112635894 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 14 Computer Method Summary (Part 2 of 3) C-2R Mountain View Country Club 4/4/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments kT11 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 4.0 3.5 2.0 0.1 2.0 2.0 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:9 of 14 1 Computer Method Summary (Part 3 of 3) '`.e C-2R Mountain View Country Club 4/4/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat 'Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference • R-Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor* R-Val. Depth Location / Comments Slab Perimeter - 18 0.76 0.0 0 • C-1 ' HVAC SYSTEMS` a { Heating Equipment Minimum Distribution. Type Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/attic, etc) . R-Value Type Comments Central Furnace ' 80%AFUE Ducts in Attic 4.2 .. Setback C-1 Central Furnace 80%AFUE Ducts in Attic 4.2 Setback C-2 Hydronic Piping Pipe Pipe Insul. ' System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency, Location, Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R-Value ,Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4"2 Setback C-1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback C-2 t WATER HEATING SYSTEMS Ratedl Tank Energy Fact' 1 Tank Insul. Water Heater r ' Water Heater Distribution # in Input ' Cap. or: Recovery Standby R-Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A O SMITH PGCG-50-226 Small Gas Standard \ 2 40,000 50 0.62 n/a n/a t 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters; list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. ' For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 04/04/05 10.31.34 Run Code: 1112635894 EnerpyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page•10 of 14 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mountain View Country Club 4/4/2005 SYSTEM NAME FLOOR AREA C-1 2,252 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 39.5 Cooling System Output per System 60,500 Total Output (Btuh) 60,500 Total Output (Tons) 5.0 Total Output (Btuh/sgft) 26.9 ,Total Output (sgft/Ton) 446.7 Air System CFM per System , 2,055 Airflow (cfm) 2,055 Airflow (cfm/sgft) 0.91 Airflow (cfm/Ton) 407.6 Outside Air (%) . 0.0 Outside Air (cfm/sgft) 0.00 ote: values above given at ARI conditions . :ATING SYSTEM PSYCHROMETRICS 26.0OF 69.3OF 69.3OF Outside Air 0 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,897 33,176 5,369 696 29,148 0 1,659 1,457 0 0 0 0 0 0 0 0 0 1,659 1,457 TOTAL SYSTEM LOAD 1 36 493 5 369 32 063 AMANA RCC60Ai2- 39,257 . 16,114 89,000 Total Adjusted System Output 39,257 16,114 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ,earn Temperatures at Time of Heating Peak) 109.7 of Supply Air Ducts 1 of . Supply Fan Heating Coil 09.1 2055 cfm ROOMS 70.0 of 69.3 of Return Air Ducts :DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 11.0/77.4OF 78.8/66.6OF 78.8/66.5OF 60.9/59.8OF Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling, Coil 61.7 / 60.1 of 2055 cfm ROOMS 54.6% R.H. 78.8/66.60F 78.0/66.3OF Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:11 of 14' _ IHVAC. SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mountain View Country Club, 4/4/2005 SYSTEM NAME FLOOR AREA C-2 2,694 SYSTEI t Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation' Supply Fan Supply Air Ducts COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 2,552 47,499, 6,423 1,195 43,529 0 2,375 2,176 0 0 0 0 0 0 0 • 0 0 2,375 2,176 TOTAL SYSTEM LOAD 52,249 s,a23 47 882 HVAC EQUIPMENT SELECTION AMANA RCC42A2' 56,680 19,270 106,000 Total Adjusted System Output 5s,68o 19,270 1 os,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0OF 69.3OF 69.3OF 104.7OF Supply Air Ducts Outside Air 0 cfm 104.0 of Supply Fan Heating Coil 2790 cfm ROOMS 69.3 of 70.0 OF Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolin Peak 111.0/77.4OF 78.8/65.8OF 78.8/65.8OF 59.8/58.7OF Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 60.6 / 59.0 of 2790 cfm 52.0% R.H. ROOMS 78.8 / 65.8 of 4 78.0 / 65.6 of Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:12 of 14 ROOM LOAD SUMMARY PROJECT NAME Mountain View Country Club DATE 4/4/2005 SYSTEM NAME C-1 FLOOR AREA 2,252 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE C-1 C-1 1 1,897 33,176 5,369 1,897 33,176 5,369 .696 29,148 PAGE TOTAL 1 1,8971 33,1765,369 696 29,148 TOTAL 1 1,897 33,176 5,369 696 29,148 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Pagel of 14 ROOM LOAD SUMMARY PROJECT NAME Mountain View Country Club DATE 4/4/2005 SYSTEM NAME C-2 FLOOR AREA 2,694 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE C-2 C-2 1 2,552 47,499 6,423 2,552 47,499 6,423 1,195 43,529 t PAGE TOTAL 1 2,552 47,499 6,423 1,195 43,529 TOTAL 1 2,552 47,499 6,42311 1,195 43,529 EnergyPro 3.1 By EnergySoft_ User Number. 2655 Job Number. Page: 14 of 14 A II � PATIO q -0• 6 CIO"` 0 II p BR.3 o . 2 O GPr - BA 13 m CPT N �I C-2 I I II II GAR cor+c FENESTRATION SCHEDULE # WINDOW SIZE FENESTRATION AREA 1 3'-0" x 5'-0" 15 SF 2 2 x 3'-0" x 6'-0" 36 SF 3 1'-6" x 2'-6" 3.8 SF 4 2 x 3'-0" x 6'-0" 36 SF 5 3 x 3'-0" x 6'-0" 54 SF 6 8'-0" x 8'-0" 64 SF 7 8'-0" x 8'-0". 64 SF 8 2x3'-0"x6'-0" 36 SF 9 T-0" x 6'-0" 42 SF 10 3'-0" x,5'-0" 15 SF 11 1'-6" x 2'-6" 3.8 SF 12 2xV-6"x6-0" 18SF 13 1'-6" x 2'-6" 3.8 SF 24 25 24 30605H -TO60FX 50605H g 30505H x I KIT. O 10 DW 22 d) GREAT RM. I I EALST 0 q'—O' . C.PT . � ao23s� — --� r — x _ 3: .. PD_R z M 3R— I of q'-0• oPr I I MBA 21 m � x I �� FOYER q'°'; I cL I I m a s I L • 19 I T- BR3 19 in I .0 29 I B-0 BONUS RM q'-0' # VOL. 20 N I CPT q _ 4 305011 5H �..1616RNDtl����� -------- 15 14 O .19p NIBR —2 m CPT cv II ® DECK BA I CL EL,—oA5T CPT z _ I� _ _ — .I . r q 7/-r-r T ,. 1J/L11 16265H 16265H � 17 117 � I � x d. I m (3) 2 405H m I FENESTRATION SCHEDULE , # WINDOW SIZE FENESTRATION AREA 14 1'-6" x 1'-6" 2.3 SF 15 T'0"x5'-0" 15 SF 16 3 x 2'-6" x 4'-0" 30 SF 17 2 x 1'-6" x 2'-6" 7.5 SF 18 T-6" x 4'-0" 14 SF 19 4 x T-0" x 5'-0" 60 SF 20 1'-6" x 2'-6" 3.8 SF 21 .3 x T-0" x 5'-0" 45 SF 22 8'-0" x 8'-0" 64 SF 23 8'-0" x 8'-0" 64 SF 24 2 x 3'-0" x 6'-0" 36 SF 25 T-0" x 6'-0" 42 SF 26 T-0" x 5'-0" 15 SF 27 T-0" x 8'-0" 24 SF 28 1'-6" x 2'-6" 3.8 SF '29 `3 x 1'-6"-z-3'-0".. _ �. 13.5'SF 30 3'-6" x 4'-0" 14 SF