12-0536 (RER) Title 24J,
si
BUILDING ENERGY ANALYSIS REPORT
PROJECT: '
Recore Residence
81555 Carboneras
La Quinta, CA
Project Designer:
Curt Shupe.
MAY 14 2012
By Report Prepared by:
Joan D. Hacker
lnsu-form, Inc.
77-810 Las Montanas Road; Suite 201
Palm Desert, Ca 92211
760-345-1352
CITY OF LA QUINTA
BUILDING. & SAFETY DEPT.
Job Number: APPROVED
FOR CONSTRUCTION
' OATS 5 W 2812 gY ® -
t . Date:
3/30/2012
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This.program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Enefg Pro 5.1-b Ene Soft User Number: 2655 RunCode: 2012-03-30T11:28:16 !D:
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures. Summary
1
2
3
8 �
PERFORMANCE CERTIFICATE: Residential. Part 1 of 5)'
CF -1 R
Project Name
Recore Residence
Building Type ® Single Family ❑ Addition Alone
O Multi Family ® Existing+ Addition/Alteration
Date
313012012
Project Aooress
81555 Carboneras La Quinta
calitornia Energy climate zone
CA Climate Zone 15
Total Gond. Floor Area
235
Addition
914
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade None 121 Perim = 320' Existing .
Wall Wood Framed R-11 518 Existing
Roof. Wood Framed Attic R-22 121. Existing
Slab Unheated Slab -on -Grade None 114 Perim = 15' New
Wall Wood Framed R-13 384 New
Roof Wood Framed Attic R-38 114 New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status ,
Front (SVIO 24.0 0.710 0.73 2.0 none Bug Screen New
Left (N149 4.0. 0.710 0.73 2.0 none Bug Screen Exisfing
Left (NVtq 4.0 0.710 0.73 2.0 none Bug Screen Existing
Rear (NE) 6.0 0.710 0.73 2.0 none Bug Screen New
HVAC SYSTEMS
QW. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE Packaged Air Condition 12.0 SEER Setback
Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
Living Zone Ducted Ducted Attic, Ceiling ins, vented 4.2
Existin g
WATER HFATIAir
ui . I ype Gallons Min. Eff Distribution : Status
1 Instant Gas 0 0.63 No Pipe Insulation
Altered
of 11
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Recore Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
3/30/2012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater.. The inspector must receive a
completed CF -4R form for each of the measures listed below. for final to be given.
The HVAC System Living Zone incorporates HERS Verified Refrigerant Chan7e or a Charge Indicator Display.
Energypro 5.1 by EnergySoft User Number.- 26AA v....�...,.,. ��� � .,....,,�..
P0109 4 of 11
PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R
Project Name.
Building Type m-Sindle Family ❑ Addition Alone
Date
Recore Residence •
I ❑ Multi Family m -E)dsting+ Addition/Alteration
1313012012
ANNUAL ENFRGY USE SUMMARY
Standard Proposed Margin
TDV MuMf -Y6
Space Heating 54.31 49.99 4.32
Space Cooling 24x70 25924 -18.54
Fans 6247 66.00 -353
Domestic Hot Water 74.57 55.84 18.73.
Pumps 0.00 0.00 0.00
Totals 432.05 431.07 a98
Percent Better Than Standard: 0.2%
BUILDING COMPLIES -HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (SHO 2Wdog Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S VV) 150 24
Fuel Available at Site: Natural Gas (NtM 320 8
Raised Floor Area: 0 (NE) 150 6
Slab on Grade Area: 235 (SE) 320 0
Average Ceiling Height: 8.0 Roof 235 0
Fenestration Average U -Factor: 0.71. TOTAL: 38
Average SHGC: 0.73 Fenestration/CFA Ratio: 16.2%
REMARKS..
STATEMENT OF COMPLIANCE
This certificate of compliance r'ists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of. Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
Address 77=810 Las Montanas Road, Suite 201 Name Joan D. Hacker 3/30/2012
City/State/ZipCity/State/Zip Palm Desert Ca 92211. Ptsm 780.345-1352
Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in
this set
of construction documents is consistent with the other compliance forms and worksheets,
with the specifications, and
with any other calculations submitted with this permit application,:and recognizes that compliance duct
using design,
duct sealing,. verification of refrigerant charge, insulation installation
quality, and building envelope sealing require
installer testing and certification and field verification
by an approved HERS rater.
Designer or Oiarner (per Business & Professions Code)
Company Curt Shupe
Address Name
QWState/Zip . Phone
Signed . License 4 Date
Ene=Pro5.1 by EnemySofl UserNumh4r• 9a-9 o....._�_..,,.... __ _
-vo-wi n:ca:7b 10. Pago 5 of 11
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF-1 R
Project Name
Recore Residence
Building Type ®. Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
13/30/2012
BUILDING ZONE INFORMATION
Floor Area
System Name Zone Name New Existing Altered Removed Volume Year Built
Living Zone Existing Living 121
968 1981
Addition 114
912
Totals 114 121 0 0
HVAC SYSTEMS
System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Living Zone 1 Centra! Fumace 78% AFUE Packaged Air Conditione 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Duct
System Name Heating Cooling Duct-Location R-Value
Ducts
Tested? Status
Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
13
WATER HEATING SYSTEMS
S stem Name
AQUASTAR 125 VP
Standard Gas 50 gal or Le
Q
1
1Small
_—TvDa
Instant Gas
Gas
Distribution
NO-Pipe Insulation
prealtered for Above
Rated
Input
Btuh
125,000
40,000
Tank
Cap.
al
0
50
Energy Standby
Factor Loss or
or RE Pilot
0.63 n1a
0.53 n/a
Ext.
Tank
Insul. R-
Value
n/a
n/a
PIPING
Status
Altered
MULTI-FAMILY WATER
Control
HEATING DETAILS HYDRONIC HEATING SYSTEM
Hot Water Piping Length
ft �
0
Pipe
-Qtv. HP Plenum Outside Buried Q — System Name Len th
Pipe
Diameter
Insul.
Thick.
❑
❑
User Number. 2655 a,...r_..ae.
Ens Pro5.1 b EnergySoft
Page 7 of 11
UANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name Date
Recore Residence 1313012012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
Fe —compliance -approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 -R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (`) below. This Mandatory Measures Summaryshall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures: .
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the'
installation of a Cool Roof is specified on the CF -1 R Form.
150(a): Minimum R-19 insulation in wood -frame ceiling ore uivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed desi n labeled R -Value.
150(c): Minimum R-13 insulation in wood -frame wall ore uivalent U -factor.
!§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor.
150 : Air retarding wrap is tested labeled and installed according to ASTM El 677-95(2000) when specified on the CF -1 R Form.
§150(g): Mandatory Vapor barrier installed in'Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%'; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or. lass door covering the entire opening of the firebox.
§150(e)l B: Masonry or factory -built fireplaces have a combustion outside air Intake, which is at least six square inches in area and is
equipped with a with a readily accessible, o erable and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150(h): Heatin and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA.
§150(1): Heating systems are equipped with thermostats that meet the setback requirements of .Section 1 12 c .
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulatiori where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water Pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table .150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§1 50(1)3A: Insulation is protected from damage including that due to sunlight, moisture equipment maintenance, and wind
§1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation
EnergyPro 5.1 by EnergySoff User Number. 2655 RunCode: 2012-03-30711:28:16 /D:
.Page 8 of 11
MANDATORY MEASURES SUMMARY: Residential.. (Page 3 of 3 MF -1 R
Project Name
Date
Recore Residence
1313012012
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
.EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION. 1: Permanently installed low efficacy luminaires. shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site isnot required to comply with §150 k 11. .
§150(k)12: Luminaires recessed into insulated ceilings shall be listed.for.zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air.
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off. switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the phbtocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:.Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor i5 automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five wafts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134 and 146..
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
5.1 by EnergySoti User Number. 2655 RunCode: 2012-03-30T`11:28:16 Q
Page 10 of 11
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
project Name
Date
Recore Residence
3/30/2012 .
System Name
Floor Area
Living Zone.
235
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 713
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perS tem 56,000
11,026
1,766 417
17,181
Total Output Stuh 56,000
0
Output Btuh! ft 238.3
935
1,221
Cooling System..
0
0
Output perSystem 36,000
0
0 0
0
Total Output Btuh 36,O
0
1,766
.0
Total Output ons 3.0
935
1,221
Total Output Btuh/s ft 153.2
Total Output s ftlTon 78.3
12,896
19,622
Air System
CFM per System
1.300
HVAC EOUIPMENT SELECTION
Alrflow cfm
1,300
Existing HVAC 21,975
11,349
56,000
56,000
Jan 1 AM
Airflow cfm/s ft 5.53
Airflow cfm/Ton 433.3
Outside Air % 0.0%
_ Total Adjusted System Output 1 21,9751.
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
11,349
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
69 OF 110 OF 110 OF
A
M
Outside Air
-4 r-
0 cfm
Heating Coil Supply Fan
1,300 c fm
109 OF
°
69F"
Reil
r
70 OF
COOLING SYSTEM PSYCHROMETICS Alm Cream Tem tures at Time of CoolIng Peak
112/78°F
79%67°F 63/62°F 63!62°F
'EITT
Outside Air
0 cfin
Cooling Coil Supply Fan
OF
1,300 cfm
63 / 62
57.7%
79/67°F
78/67°F
5.1 by EnergySoR User Number. 2655 RunCode• 2012-03-307112816 ID
Page 11 of 11