Loading...
0112-182 (CSCS) Title 24TITLE 24 Energy Conservation, Standards Compliance Report STAPLES OFFICE SUPERSTORE ONE ELEVEN LA QUINTA CENTER LA QUINTA December 212001 o Job Number: 20250A 1 Prepared For. - DESERT CITIES DEVELOPMENT 40, A&46753 ADAMS CITY OF LA QUINTA LA QUINTA, CA 92253 BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAA BY Madan s enterprises ♦®®v® Catherine M. Madlin, Certified Energy Analyst Post Office Box 1443 v Palm Springs, CA 92263 x 760-322-5004 / 323-3644 (fax) E-mail: CMadlin@aol.com Madlin's en terpfises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) Title 24 Energy Conservation Standards Compliance Report This proposed project has been reviewed for compliance with the 1998 State of California Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design described in this compliance portfolio is in conformance with the standards as outlined in the attached compliance forms and documentation. Date: December 21, 2001 Job Number: 20250A Prepared For: DESERT CITIES DEVELOPMENT Owner's Name: WASHINGTON PLAZA Project Name: STAPLES OFFICE SUPERSTORE Project Location: ONE ELEVEN LA QUINTA CENTER - LA QUINTA Method of Compliance: ENERGYPRO CERTIFIED COMPUTER PROGRAM Orientation Of Entry: SOUTH Certified Energy Analyst Catherine M. Madlin . NR 98-90-544 r r r r R 98-90-144 CADEC ' wz� • California Association of Building Energy Consultants • Post Office Box 1443 v Palm Springs, Ca 92263 v TABLE OF CONTENTS Table of Contents 1 Nonresidential Performance Title 24 Forms 2 Form ENV -3 Proposed Construction Assembly 14 Form ENV -MM Envelope Mandatory Measures 16 Form LTG -MM Lighting Mandatory Measures 17 Form MECH-MM Mechanical Mandatory Measures 18 HVAC System Heating and Cooling Loads Summary 20 EnergyPro 3.1 By EnergySoft Job Number: 20250A User Number: 1069 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME Staples Office Superstore This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE 12/21/01 PROJECT ADDRESS Highway 111 - La Quinta Center La Quinta DATE OF PLANS DATE Catherine M. Madlin PRINCIPAL DESIGNER - ENVELOPE Carl Cox, AIA, Architect TELEPHONE 760-347-4007 Building Permit # DOCUMENTATION AUTHOR Madlin's Enterprises TELEPHONE (760) 322-5004 Checked by/Date Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR DATE OF PLANS DATE Catherine M. Madlin BUILDING CONDITIONED FLOOR AREA 24,106 Sq.Ft CLIMATE ZONE 15 BUILDING TYPE for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION KI 5?1 X 1. I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to NEW CONSTRUCTION F—] ADDITION u ALTERATION U EXISTING +ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR SIGNATUR DATE Catherine M. Madlin /�-a/o/. The Principal Designers hereby certify that the proposed building design represented in the construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. KI 5?1 X 1. I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. F1 n F1 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures EW - Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATU NO. IAT / Carl Cox AIA Architect 0 LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures / Required Forms L 'G-1 PRINCIPAL LIGHTING DESIGNER - NAME SIGNATUR _ LIC.. NO D T Carl Cox AIA Architect LG- �� MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures M EH -1 MECH-2 MECH-3 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATU LIC. N DA Carl Cox AIA Architect Cr �-� 00 Energy*o 3.1 By EnergySoft User Number. 1069 Job Number: 20250A Page:2 of 23 PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 of 3 PERF -1 Staples Office Superstore I DATE12/21/01 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r ENERGY COMPONENT Standard Design Proposed Design Compliance Margin ❑ SWdam ❑ Proposed Space Heating Space Cooling Indoor Fans Heat Rejection Pumps& Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: 1.99 3.60 -1.61 s°°` H-brc 1 55.47 49.52 5.95 Go -C -*V 40.96 44.37 -3.41 ""-"- 0.00 0.00 0.00 Heat Rejwion 0.00 0.00 0.00 ftP5awm 18.79 18.28 0.51 °HW 52.18 44.30 7.88 10 20 30 4D 50 kBtu/sgft•yr 14.93 14.93 0.00 ReOCpmda 0.00 0.00 0.00 p- 0 184.32 175.00 9.32 BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (South) 180 deg Conditioned Floor Area 24,106 sqft. Unconditioned Floor Area o sgfL Conditioned Footprint Area 24,106 sqft. 1 10 13 Orientation Front Elevation (South) Left Elevation (West) Rear Elevation (North) Right Elevation (East) Total Roof Gross Area sqft. sqft. sqft. sgft. sqft. Glazing Area Glazing sqft. sqft. sgfL sqft. sqft. sgft. Ratio 2,733 444 16.2% 2,552 0 0.0% 2,255 0 0.0% 295sgft. 0 0.0% 7,835 444 5.7% 24,106 0.0% Standard Proposed Lighting Power Density 1.772 W/sgft. 1.504 W/sgft. Prescriptive Env. Heat Loss 4,530 6,751 Prescriptive Env. Heat Gain 381,015 430,892 Remarks: Run Initiation Time: 12/21/01 12:41:36 Run Code: 1008967296 EnergyPro 3.1 By EnergySoft User Number. 1069 Job Number. 20250A Page:3 of 23 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 Of 3 PERF -1 PROJECT NAME Staples Office Superstore DATE 12/21/01 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. f)1 (W/ D Ctrl. Credits (Wlsf)2 Tail red Proc. Loads (W/sf) LPD (Wlsf)3 Vent. (cfmisf) Zones 1-7 Entry Lobby (Main Entry & Assembly 210 1.329 1.67 Sales Retail/Wholesale Sales 19,623 1.673 0.27 Zones 8 Cash Bank/Financial Institution 105 0.88E 0.15 Percision Work Precision Industrial 70 0.88E 0.15 Offices Office 95 0.97E 0.15 Lockup Industrial Storage 200 0.62C 0.15 Hallway Corridor/Restroom/Support 74 1.257 0.15 Zones 9 Receiving Industrial Storage 2,198. 0.491 0.15 Zone 10 Electrical/Mechanical Electrical & Mechanical 260 0.596 0.15 Training Room Classroom 144 0.646 0.38 Kitchen Kitchen & Food Prep 187 1.989 0.15 Janitor / Storage Industrial Storage 144 0.43 0.15 Restrooms & Corridors Corridor/Restroom/Support 7961 1.166 0.15 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST lu�al crnvitemenL aycrwy snvuru pay specrai aaennon to tne items specmea m tors cnecKnst. i hese items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. __ The HVAC System "Lennox LGA -060H" was manufactured prior to 10/29/2001 - provide date of manufacture. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp Run Initiation Time: 12121/01 12:41.36 Run Code: 1008967296 EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number. 20250A PageA of 23 ENVELOPE COMPLIANCE SUMMARY ' Performance ENV -1 PROJECT NAME Staples Office Superstore Area U -Fac. Act. Am. SHGC Glazing Type DATE 12/21/01 OPAQUE SURFACES 54 1.220 180 0.83 NR Site Built Sn I Mtl Or Entry 2 Window ' I Surface # Type i Framing I TypeArea 1 Act. U -Fac. Azm, I Tilt Solar Gains y/N Form 3 Reference Location I Comments 1 IRoof IMetal 210 1 0.050 0 1 0 X11 IR-19Ri id Insul - Mtl Deck Entry 2 lWall ;None 262 1 0.690: 180 190 X11 18" Solid CMU Wall Entry 3 Wall INone 11 367 1 0.690 1 180 I 90 X 8" Solid CMU Wall Sales 1 4 Roof IMetal 19623 1 0.050 1- 0=0 X I R-19 Ri id Insul - Mtl Deck Sales j 5 Wall 1None 1,459 1 0.690 1 270 1 90 X 18" Solid CMU Wall Sales 1 6 jDoor None 1 21 1 0.581 1 270 90 X I Hollow Metal Door Sales 7 ,Wall jNone 1 40 0.690 1 270 90 X 18" Solid CMU Wall Cash 1 8 IRoof Metal 1 105 0.050 1 0 0 X I R-19 Rigid Insul - Mtl Deck Cash 1 9 1Wall (None 1160 1 0.690 1 270 90 X 18" Solid CMU Wall Percision Work 10 lRoof jMetal 1 70 1 0.050 1 0 0 X R-19 Rigid Insul - Mtl Deck Percision Work j 11 iWall None 1 300 1 0.690 1 180 j 90 8" Solid CMU Wall Offices I 12 Roof Metal 1 95 0.050 I 0 1 0 X R-19 Rigid Insul - Mtl Deck Offices 13 !Roof jMetal ; 200 1 0.050 1 0 0 2LR-19 Rigid Insul - Mtl Deck Lockup 14 jWall 15 (Wall 16 IRoof INone ;None jMetal 210 1 360 1 74 1 0.690 1 1 0.690 1 1 0.050 1 270 1 180 1 0 1 90 90 0 X IXII 18" XII I 8" Solid CMU Wall Solid CMU Wall R-19 Ri id Insul - Mtl Deck Lockup Lockup Hallway 17 iWall (None 11,296 1 0.690 1 0 1 90 X 8" Solid CMU Wall Receiving i 18 (Roof IMetal 12,198 1 0.050 1 0 ; 0 A R-19 Rigid Insul - Mtl Deck Receiving 19 !Wall jNone 1215 j 0.69090 90 8" Solid CMU Wall Receiving 20 IDoor 1None 1 80 1 0.581 90 90 X Hollow Metal Door Receiving FENESTRATION SURFACES Run Site Assembled Glazing U %.neuK oox it aunamg is- -Iuu,uuu sqn or l:rA ano - 10,000 sqft vertical glazing then NFRC Certification is required. FAllnlu rJFRR 1nn_CR -4 -k-; nicor+, _i _, # I Type Area U -Fac. Act. Am. SHGC Glazing Type Location / Comments__ 1 Window 54 1.220 180 0.83 NR Site Built Sn I Mtl Or Entry 2 Window 84 1.250 180 0.80 Single Mtl Clear Default 3 Window 153 1.220 180 0.83 NR Site Built Sn I Mtl Cir -Entry Sales 4 Window 153 1.220 180 0.83 NR Site Built Sn I Mtl Clr Sales EXTERIOR SHADING # Exterior Shade Type SHGCJ Window Hgt. Wd. Overhang Len. Hat, LExt RExt. Dist. Left Fin Len. Ht. Right Fin Di t. en. H t. 1 None 0.76 4.5 12.0 13.0 0.5 13.0 13.0 2 None 0.76 7.0 12.0 13.0 5.0 13.0 13.0 3 None _ 0.76 4.5 12.0 13.0 0.5 13.0 13.0 4 None 0.76 4.5 12.0 13.0 0.5 13.0 13.0 _ Run Initiation TiMe: 121 2:4 Run1008967296 EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20250A Page:5 of 23 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME Staples Office Superstore "11U ^ """" L30'""'y " -- -"",uuu syn ui v rm anu — i u,uuu sqn vemcai glazing inen Nt-KL; cerutication is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form. # Type AreaIU-Fac. Act. Azm. DATE 12/21/01 OPAQUE SURFACES I i I Surface Framing # Type Type I i Act. I Area IU -Fac. Azm I Tilt Solar Gains y/N Form 3 Reference Location / Comments .21 Iwall (None 641 1 0.690 1 270 1 90 XII 18" Solid CMU Wall Receivin 22 IDoor None 21 i 0.581 1 270 1 90 XII I Hollow Metal Door Receiving 23 (Roof IMetal 117 0.050 0 0 X I R-19 Ri id Insul - Mtl Deck Electrical/Mechanical 24 IWall INone 177 0.690 , 0 90 X 18" Solid CMU Wall Electrical/Mechanical 25 (Roof IMetal 143 0.050 0 0 X I R-19 Rigid Insul - Mtl Deck Electrical/Mechanical 26 IWall INone 1345 0.690 1 0 1 90 X 8" Solid CMU Wall Electrical/Mechanical 27 Roof Metal 1144 1 0.050 1 0 1 0 X I R-19 Rigid Insul - Mtl Deck Training Room 1 28 IRoof IMetal 1 187 1 0.050 1 0 1 0 X I R-19 Rigid Insul - Mtl Deck Kitchen 29 Poof IMetal 144 0.050 1 0 I 0XII I R-19 Ri id Insul - Mtl Deck Janitor / Storage 1 30 lWall INone 328 0.690 1 0 1 90 XII 18" Solid CMU Wall Restrooms & Corridors 31 IRoof IMetal 1311 , 0.050 1 0 1 0 x1l I R-19 Ri id Insul - Mtl Deck Restrooms & Corridors I 32 (Wall (None 1 109 j 0.690-T 0 1 90 XII 18" Solid CMU Wall Restrooms & Corridors 133 lRoof IMetal 1485 1 0.050 1 0 1 0 XII I R-19 Ri id Insul - Mtl Deck Restrooms & Corridors i I i i i ' I I •4 Run Code: 1008967226 EnergyPro 3.1 By Energysoft User Number: 1069 Job Number. 20250A Page:6 of 23 . I I I I I I I 1 FENESTRATION SURFACES Site Assembled Glazing "11U ^ """" L30'""'y " -- -"",uuu syn ui v rm anu — i u,uuu sqn vemcai glazing inen Nt-KL; cerutication is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form. # Type AreaIU-Fac. Act. Azm. SHGC Glazing Type Location / Comments EXTERIOR SHADING ## Exterior Shade Type Window SHGC Hgt. Wd. Overhang Left Fin Len. Hgt. LExt.RExt. Dist. Len. H Right Fin t. Dist. Len. H t. Run Initiation Ti 12/21101 •4 Run Code: 1008967226 EnergyPro 3.1 By Energysoft User Number: 1069 Job Number. 20250A Page:6 of 23 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 PROJECT NAME DATE Staples Office Superstore 12/21/01 I eftenc I II 1 umin�iro Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per Lamp y^��v v DESCRIPTION (Lamp + Ballast)l Total Waw Watts B 4 ft Fluorescent T8 Elec F32T8 2 32 Electronic 1.0 130 62.0 8,060 131 (2) 4 ft Fluorescent T8 Elec F32T8 ___2 32 Electronic 1.0 14 62.0 868 B1 E 2 4 ft Fluorescent T8 Elec F32T8 2 32 Electronic 1.0 51 62.01 310 132 f4_4 ft Fluorescent T8 Elec F32T8 4 32 Electronic 2.0 28 124.0 3,472 62EM (4) 4 ft Fluorescent T8 Elec 4 32 Electronic 2.0' 10 124.0 _ 1,240 B3 S4) 4 ft Fluorescent T8 Elec F32T8 4 32 Electronic 2.0 13 124.0 1,612 BE 2) 4 ft Fluorescent T8 Elec F32T8 9 32 Electronic 1.01 121 62.0 744 C (2) 4 ft.Fluorescent T8 Elec F32T8 2 32 Electronic 1.0 7 62.0 434'I E & E1 (3 4 ft Fluorescent T8 (Tandem) Elec F32TS 3 32 Electronic 1.5 27 93.0 2,511 K 400w Metal Halide MH400 1 4001 Magnetic Standard 1.0 35 461.01 16,135 L 45w Track Light 45 w per Foot Track Lights 1 45 No Ballast 16 45.0 720 W 150w Surface Mount Incandescent 1150W 1 150 No Ballast 1 150.0 150 36,256 Lightin Schedule on Plans Subtotal from this Page Show �xterior Lighting Meets Total 3s,25s 1-1 Efficacy and Control Requirement of S30(c) Portable Lighting (From LTG -1) =] ❑.Control Requirements of 031(f) Less Control Credit Watts (From LTG -3) Adjusted Actual Watts 36,256 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION I I CONTROL (Room # or Dwg. #) IDENTIFICATION CONTROLTYPE (Occupant, Dayliqht, Dimming, etc.) 1919 NOTE TOl FIELD NOTE TO FIELD I EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20250APaae:7 of 23 (LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 PROJECT NAME DATE Staples Office Superstore 12/21/01 TABLE 18 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET D D K F 0 D D LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID Description FIXT. FIXTURE (SF) AREAS (D x E) (C x E) TOTAL ROOM # TOTAL AREA OR ZONE ID (SF) Designer needs to provide detailed documentation that the lig/ level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTAL 1 0 BUILDING SUMMARY - PORTABLE LIGHTING BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1 B+1 C) TOTAL WATTS (FROM TABLES 1A+1B) BUILDING TOTAL 0 0 Run Initiation Time: 12/21/01 12:41:36 Run Code: 1008967296 EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number. 20250A Page:8 of 23 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Staples Office Superstore 12/21/01 SYSTEM FEATURES SYSTEM NAME TABLES: TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN AIR CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE PIPEIDUCT INSULATION PROTECTED? PIPE TYPE (SUPPLY, RETURN, ETC.) PIPE INSULATION REQUIRED? VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS TABLES: DHW Heater ( Zones 1-7 _ Zones 8 NOTE TO FIELD HEAT PUMP THERMOSTAT? TIME CONTROL n/a Programmable Switch Programmable Switch ELECTRIC HEAT? n/a Heating & Cooling Required Heating & Cooling Require _ l: Inlet Vanes P: Variable Pitch n/a n/a n/a Sensor n/a n/a n/a n/a n/a n/a n/a Constant Volume Constant Volume n/a No No HEAT AND COOL SUPPLY RESET? n/a No No ECONOMIZER n/a Constant Temp Constant Tem A: Auto G: Gravity n/a Constant Temp Constant Temp n/a n/a n/a n/a Outside Air Cert. Outside Air Cert. n/a Auto Auto n/a — Fixed Tem (Integrated) No Economizer n/a 5702 cfm 82 cfm Electric Res Gas Furnace Gas Furnace 100% 78% AFUE 78% AFUE AO SMITH ELJF-20 Packaged DX Packaged DX n/a 11.0 EER 9.7 SEER / 8.6 EER n/a Lennox LGA -120H Lennox GCS16-024 n/a n/a Ducts in Attic 4.2 Ducts in Attic4.2 n/a n/a Ducts in Attic 4.2 Ducts in Attic 4.2 Yes Yes Yes Supply HW Yes Yes Yes n/a No No CODE TABLES: Enter code from table below into columns above. —� HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy H: Heating C: Cooling Enter Number of Isolation Zones. _ l: Inlet Vanes P: Variable Pitch _ VAV MINIMUM POSITION CONTROL? Sensor B: Both V: VFD SIMULTANEOUS HEAT/ COOL? Y: Yes N: No M: Manual Timer 0: Other C: Curve --- HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert M: Out Air Measure A: Auto G: Gravity : Air : Water N: Not Required Enter Outdoor Air CFM. Note: This shall be no PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? D: Demand Control N: Natural EC: Economizer Control See Section * less than Col. H on MECH-3. SEALED DUCTS IN CEILING/ROOF SPACE? EnergyPro 3.1 By EnergySoft User Number. 1069 Job Number: 20250A Paoe:9 of 23 1 'ERTIFICATE OF COMPLIANCE Performance MECH-'I PROJECT NAME DATE Staples Office Superstore 12/21/01 SYSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL _ ECONOMIZER TYPE DESIGN AIR CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE _ COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE PIPE/DUCT INSULATION PROTECTED? PIPE TYPE (SUPPLY, RETURN, ETC.) PIPE INSULATION REQUIRED? VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE ' Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Tem Constant Temp n/a Outside Air Cert. Auto No Economizer 330 cfm Gas Furnace 78% AFUE Packaged DX 10.3 SEER / 10.3 EER Lennox LGA -060H Ducts in Attic 4.2 Ducts in Attic 4.2 Yes Yes No Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Temp Constant Temp n/a Outside Air Cert. Auto _ Fixed Tem (Integrated) 263 cfm Gas Furnace 78% AFUE Packaged DX 10.2 EER Lennox LGA -088H Ducts in Attic 4.2 Ducts in Attic 4.2 Yes Yes No NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. 71 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME =ATESta les Office Superstore 2/21/01 ICUILLEED T SUMMA!3Y SUPPLY FAN RETURN FAN System Name Efficiency Tons PUMPS BHP Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 4,000 3.00 86.5% 97.0% none 77.0% 100.0% none Lennox GCS16-024 Constant Volume Blow -Through 800 0-U Blow -Through 2,000 1.50 84.0% 97.0% none Lennox LGA -088H Constant Volume Blow -Through 2,860 2.00 84.0% 97.0% none BOILER51AMMARY TANK INSUL. Energy Factor or Recovery Efficiency Standby Loss or Pilot System Name ' System Type Distribution Type Qty Rated Input (Gals.) Vol. Ext. R -Val. O SMITH ELJF-20 Storage Elec. Standard 1 20,478 19 0.93 n/a n/a CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qty. output Aux. kW I Eff. Output Sensible Efficiency Economizer Type Lennox LGA -120H Packaged DX 7 115,000 0.0 78%AFUE 120,000 96,00 11.0 EER Fixed Temp (Integrate( Lennox GCS 16-024 packaged DX 1 40,000 0.0 78% AFUE 24,000 19,20 9.7 SEER /8.6 EER No Economizer Lennox LGA -060H Packaged DX 1 98,800 0.0 78%AFUE 57,000 39,90 10.3 SEER / 10.3 EER No Economizer Lennox LGA -088H Packaged DX 1 100,000 0.0 78%AFUE 90,000 72,00 10.2 EER Fixed Temp Integrate ; CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Lennox LGA -120H Constant Volume Blow -Through 4,000 3.00 86.5% 97.0% none 77.0% 100.0% none Lennox GCS16-024 Constant Volume Blow -Through 800 0-U Blow -Through 2,000 1.50 84.0% 97.0% none Lennox LGA -088H Constant Volume Blow -Through 2,860 2.00 84.0% 97.0% none EnergyPro 3.1 By 77.0% 100.0% none Lennox LGA -060H Constant Volume Blow -Through 2,000 1.50 84.0% 97.0% none Lennox LGA -088H Constant Volume Blow -Through 2,860 2.00 84.0% 97.0% none EnergySoft User Number: 1069 Job Number: 20250A Paae:11 of 23 MECHANICAL EQUIPMENT SUMM4RY Part 2 of 2 MECH-2 PROJECT NAME Staples Office Superstore DATE 17/71 /(11 VA V TERMINAL BOX__ Min. CFM il System Type _ Qty. _Ratio Type DeltaT MARY _ EXHAUST FAN Room Name _9ty, CFM BHP Motor Eff. Drive Eff. Motor Drive CFM I BHP Eff. Eff. Tvoe Output _. EXFIAI�S'T FAN Room Name _y, CFM BHP Motor Eff. Drive Eff. EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number. 20250A Page: 12 of 23 MECHANICAL VENTILATION MECH-31 NAME es Office Su DATE 12/21/01 MECHANICAL VENTILATION o a© 0 0 0© 0 0 0 0 OCCUPANCY BASIS AREA BASIS MIN. CFM (ExF) ZONEISYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) Entry 210 1.07 225 Sales 19,6231 0.25 4,906 Zones 1-7 15.0 11 0.9 Cash 105 0.15 16 Percision Work 70 0.15 10 Offices 951 0.15 14 Lockup 200 0.15 30 Hallway 74 0.15 11 Zones 8 15.0 55 1.9 Receiving 2,198 0.15 330 Zones 9 8.0 15.0 119 Electrical/Mechanical 260 0.15 39 Training Room 144 0.38 55 Kitchen 187 0.15 28 Janitor / Storage 144 0.15 22 Restrooms & Corridors 796 0.15 119 Zone 10 OCCUPANCY BASIS NO. I OF PEOPLE CFM PER PERSON MIN. CFM (ExF) 23.3 15.0 350 356.8 15.0 5,352 Total 1.0 15.0 16 0.7 15.0 11 0.9 15.0 14 2.01 15.0 30 0.7 15.0 11 30 30 Total 22.0 15.0 330 Total 2.6 15.0 39 3.7 15.0 55 1.9 15.0 28 1.4 15.0 22 8.0 15.0 119 55 55 Total 28 28 22 22 1191 119 263 263 REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO TRANS - FER AIR 350 350 5,352 5,352 5,702 5,702 16 16 11 11 14 14 30 30 Ill 11 82 82 330 330 330 330 391 39 55 55 28 28 22 22 1191 119 263 263 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20250A Page:13 of 23 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 ECT NAME Office DATE 12/21/01 COMPONENT DESCRIPTION ASSEMBLY NAME R-19 Ri id Insul - Mtl Deck `HEAT ASSEMBLY Floor THICK- NESS (in.) CAVITY R -VALUE (Rc) TYPE (check one) Wall SPECIFIC HEAT (Btu/F-Ib) p Uj X Ceiling 1 Roof OUTSIDE SURFACE AIR FILM ❑ El ❑ ❑ ❑ ❑ ❑ ❑ ❑ FRAMING MATERIAL Metal O Z FRAMING %° 0 �o 1 Roofing, Buiit-Up 0.375 0.330 Framing 2.19 0.351 0.77' 15% (16" o.c. Wall) Insulation, Cellular Polyisocyan u rate .2.650 19.080 12% (24" o.c. Wall) 0.44 0.22 0.10 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 0.060 0.000 7% (24" o.c. Floor/Ceil.) CONSTRUCTION COMPONENTS R -VALUE `HEAT CAPACITY (Optional) THICK- NESS (in.) CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (BtWF-sf) DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ El ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 0.170 — — — 1 Roofing, Buiit-Up 0.375 0.330 2.19 0.351 0.77' 2 Insulation, Cellular Polyisocyan u rate .2.650 19.080 0.44 0.22 0.10 3 Roofing, Sheet Metal 0.060 0.000 2.44 0.12 ' 0.29 4 5 _ 6 7 8 — 9 *NOTE: INSIDE SURFACE AIR FILM — 0,610 — — — Weight and Specific Heat values for materials penetrated SUBTOTA by wood 20.191 Rc framing include Rf the effects TOTAL HC members. 1 2 of the framing x + [�— x ��] = 0.050 11 Rc 1 - (Fr% /100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE COMMENTS This assembly contains metal framing. The Assembly U -Value has been calculated using the ASHRAE/CEC Zonal Cavity Method. EnergyPro 3.1 By Energy Soft User Number: 1069 Job Number: 20250A Page: 14 of 23 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME les Office Superstore DATE 12/21/01 COMPONENT DESCRIPTION A B ASSEMBLY NAME g" Solid CMU Wall *HEAT ASSEMBLY Floor THICK- NESS (in.) CAVITY R -VALUE (Rc) TYPE (check one) x Wall SPECIFIC HEAT (Btu/F-Ib) LU W Ceiling I Roof OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El 2 FRAMING MATERIAL None — Z — 1 O FRAMING % ° �0 Framing 83.33 0.20 16.67 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) CONSTRUCTION COMPONENTS A B R -VALUE *HEAT CAPACITY (Optional) THICK- NESS (in.) CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC IA X (Btu/F-sf) DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El — 0.170 — — — 1 Conc Block, Normal Weight, Conc Filled 8.000 0.600 83.33 0.20 16.67 2 3 4 5 _ 6 7 _ 8 9 *NOTE: INSIDE SURFACE AIR FILM — 0,680 1.45 Rc framing include Rf the effects — — — Weight and Specific Heat values for materials penetrated SUBTOTA by wood 83.31 TOTAL HC members. 16.7 of the framing X L + [E= X 11 Rc 1 - (Fr/° / 100) 1 / Rf Fr% 1100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20250A Page: 15 of 23 ENVELOPE MANDATORY MEASURES ENV -MM • (PROJECT NAME DATE Staples Office Superstore 12/21/01 DESCRIPTION Designer Enforcement IX § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. I� § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. JX]u § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). JAI§ 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20250A Page: 16 of 23 1 [LIGHTING MANDATORY MEASURES LTG -MM (PROJECT NAMEDATE Staples Office Superstore 12/21/01 DESCRIPTION Designer Enforcement I ^J § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device Capable of automatically shutting off the lighting. § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the tights. The area of override is not to exceed 5,000 square feet. § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. FX�§ 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. A§ 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. I § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel. u ' § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. _ EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20250A Page: 17 of 23 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-IV M PROJECT NAME DATE _ Sta Imes Office Superstore _ 12/21 /01 DESCRIPTION __ Designer Enforcement Equipment and Systems Efficiencies I^ I §111 Any appliance for which there Is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be Insulated in accordance with Standards Section 123. 0 § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint u § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. a§ 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. n§'l 22(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. 1^1§ 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20250A Page: 18 of 23 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-IVIIidI NAME les Office Superstore DATE 12/21/01 Description Designer Ventilation _Enforcement § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. n§ 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. (❑ § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or n § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or §121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or ❑ § 121(f)4 Another method approved by the Commission. Service Water Heating Systems ❑ § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. 1A I § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot Water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number. 20250A Page: 19 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY r NAME _ Staples Office Su NAME Zones 1-7 GC Number of Systems Heating System Output per System 115,000 Total Output (Btuh) 805,000 Output (Stuh/sgft) 40.6 Cooling System Output per System 120,000 Total Output (Btuh) 840,000 Total Output (Tons) 70.0 Total Output (Btuh/sqft) 42.4 Total Output (sgft/Ton) 283.3 Air System CFM per System 4,000 Airflow (cfm) 28,000 Airflow (cfm/sgft) 1.41 Airflow (cfm/Ton) 400.0 Outside Air (%) 20.4 Outside Air (cfm/sqft) 0.29 4ote: values above given at ARI conditions EATING SYSTEM PSYCHROMETRI Outside Air 5702 cfm Supply Fan 28000 cfm Outside Air 5702 cfm DATE 12/21/01 FLOOR AREA 19,833 COIL COOLING PEAK COIL HTG. PEAK CFM Sensiblel Latent CFM Fsensible Total Room Loads I 29,317 435,731 97,708 Return Vented Lighting 0 Return Air Ducts 21,787 Return Fan 0 Ventilation 5,702 229,456 74,393 Supply Fan o Supply Air Ducts 21,787 TOTAL SYSTEM LOAD 708:8:719 17210 a82 s7a HVAC EQUIPMENT SELECTION Lennox LGA -120H 689,310 89,778 805,000 Total Adjusted System Output689,310 89,778 805,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 3 pm an 12 am 'earn Temperatures at Time of Heatino Peakl Heating Coil RICS Supply Fan 28000 cfm Cooling Coil h Return Air Ducts `I at Time h Return Air Ducts 4 EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number. 20250A Supply Air Ducts ROOMS Supply Air Ducts 59.3% R.H. ROOMS 20 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY � rNAME Staples Office Superstore_ NAME T Zones 8 ENGINEERING CHECKS (Number of Systems Heating System Output per System 40,000 Total Output (Btuh) 40,000 Output (Btuh/sqft) 73.5 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 44,1 Total Output (sgfUTon) 272.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 1.47 Airflow (cfm/Ton) 400.0 Outside Air (%) 10.2 _ Outside Air (cfm/sgft) 0.15 Note: values above given at ARI conditions TING Outside Air 82 cfm _J1 rstream Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 12/21/01 FLOOR AREA 544 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,470 41,700 1,125936 37,846 0 2,085 1,892 0 0 82 3,135 1,756 82 3,859 0 0 2,085 1,8921 49,005 2,881 45 490 Lennox GCS16-024 20,812279 40,1 L Total Adjusted System Output 20,812 279 40,1 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F I nm] Supply Fan Heating Coil 800 cfm Supply Air Ducts �IROOMS b Return Air Ducts COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak O Supply Air Ducts Outside Air 82 cfm Supply Fan Cooling Coil 800 cfm 49.7% R.H. ROOMS Return Air Ducts EnergyPro 3.1 ey EnergySoft User Number: 1089 Job Number: 20250A Paae:21 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Staples Office Superstore 12/21/01 SYSTEM NAME FLOOR AREA Zones 9 _ 2,198 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 11,385 91,559 4,396 2,192 82,075 0 4,578 4,104 0 0 330 12,450 1,36 330 15,696 0 0 4,578 1 4,104 113,165 5,757 105 979 Lennox LGA -060H 37,691 17,026 98,800 Total Adjusted System Output 37,691 17,026 98,800 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 4 pm Jan 12 am LHEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak) Outside Air 330 cfm Supply Fan 2000 cfm Outside Air 330 cfm Heating Coil Supply Fan Cooling Coil 2000 cfm Supply Air Ducts ROOMS I% Return Air Ducts `S at Time Supply Air Ducts 69.5% R.H. ROOMS Return Air Ducts ` I EnergyPro 3.1 By EnergySoft User Number: 1069 . Job Number: 20250A Paae:22 of 23 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Staples Office Superstore _ 12/21/01 SYSTEM NAME FLOOR AREA Zone 10 1,531 SYSTEM LOAD EATING Outside Air 263 cfm M Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 2,105 45,430 4,425 1,317 38,340 0 2,272 1,917 0 0 263 10,598 6,700 263 12,906 0 0 2,272 1 1,917 60,57:6=11 55 080 Lennox LGA -088H 76,865 0 100,000 Total Adjusted System Output 76,865 —� 100,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK pm L-- Jan 12 am 0 Supply Fan Heating Coil 2860 cfm K Return Air Ducts `{ Supply Air Ducts ROOMS (COOLING SYSTEM PSYCHROMETRICS (Airstream Temneratures at Time of Cooling Peakl Outside Air 263 cfm 3.1 Supply Fan 2860 cfm User Number: 1069 Cooling Coil Return Air Ducts Job Number: 20250A Supply Air Ducts 45.2% R.H. ROOMS of 23 • Madlin ,S' enteiptises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 1323-3644 (fax) ..... . IT Addendum's and Notes Madlin -s enterprises Catherine M. Madlin, Certified Energy Analyst • 760-322-5004 / 323-3644 (fax) ...... V D. Shut -Off Controls (§131(d)) The Standards require that most buildings, or separately metered space greater than 5,000 square feet of conditioned space, have an automatic control to shut off the lights. Additionally, if the building has more than one floor, each floor shall have all of the lights on the floor controlled by a separate automatic control device (or control point if a multiple point control system). The areas exempted from automatic shut-off a re: • Areas that must be continuously lit imply 24 hour operation, such as hotel lobbies and 24-hour, 365 day/year grocery stores where lights are never turned off. • Corridors, guest rooms, and lodging quarters of high-rise residential buildings or hotel/motels The shut-off control need not be a single control, but may include automatic time switches, occupancy sensors, or other automatic controls (see Figures 5-8 and 5-9.) When an occupant -sensing device is used to meet the automatic shut-off requirement, it is required to be installed in accordance with manufacturer's instructions with regard to placement of the sensors. Automatic time switches with programmable solid state perpetual calendar control devices can also be used to meet the shut-off requirement. These devices are typically available with multiple channels of control, and may also be used to meet the mechanical system automatic time switch control requirements. If an automatic time switch control device is used for shut-off control, it must be certified, incorporate an automatic holiday shut-off that turns off all lighting loads for at least 24 hours and then resume normal scheduled operation. Holiday scheduling is not required for: retail stores and associated malls, restaurants, grocery stores, churches, and theaters. Areas lit in a manner requiring manual operation of the lighting system such as spaces which always have varying and unpredictable operating schedules, or spaces with lighting systems equipped with high intensity discharge (HID) lamps AND where the use of the space results in unpredictable on/off operation. The space requires manual operation because of the long er'sta rt/resta rt time of HID lamps coupled with the unpredictable schedule. NOTE.: most facilities equipped with HID lighting will not fall under this exception because an operating schedule will be reasonable to predict. A facility with a predictable operating schedule and metal halide lighting could still use automatic shut-off without posing a risk to people working or conducting business in the building. Security or emergency egress lighting that must be continuously lit, provided it does not exceed 1/2 watt per square foot and the area is controlled by switches accessible only to authorized personnel (the security or egress area must be documented on the plans) • P.O. Box 1443 v Palm Springs, Ca 92263-1443 v E-mail. Cmadlin@aol.com v rigure -)-u: limed Manual Override To Enclosed Areas or Floor if Multipoint Control Main Madlin's Panel enterpises Catherine M. Madlin, Certified Enemy Analyst v 760-322-5004 / 323-3644 (fax) ...... If an automatic time switch control device is used for shut off, the control is required to be designed with override switching devices. The Automatic ime override switching devices shall: s Switch for Enclosed • Control an area not exceeding 5,000 Building Space square feet on a single floor. For —Til malls and arcades, auditoriums, single ' tenant retail spaces, industrial facilities, and arenas, the area controlled may not exceed 20,000 square feet. • Be readily accessible • Be manually operated • Allow the operator to see the lights or area controlled or be annunciated (see definition in Section 5.1.2C) • Provide an override for not more than 2 hours. In malls and arcades, auditoriums, single tenant retail spaces, industrial facilities, and arenas -where captive -key override (see definition in Section 5.1.2C) is utilized, a 2 hour override limit is not required. rigure -)-u: limed Manual Override To Enclosed Areas or Floor if Multipoint Control Main Panel Box P A N E Automatic ime s Switch for Enclosed Building Space —Til < 5000 sf Timed Manua! verride. Manual Switch and Override . are only one device. P.O. Box 1443 v Palm Springs, Ca 92263-1443 • E-mail: Cmadlin@aol.com •