04-5040 (CSCS) Title 24TITLE 24 REPORT
Ai Y
Title 24 R�port for:
Lamppost Pizza and.Backstreet Brewery
One Eleven La Quinta Center
La Quinta, CA 92253
Project Designer:
�Carl Cox, A,.I.A. Architect
81-557 Dr. Carreon Boulevard
Indio, CA 92201
760-347-4007
. I
Report Prepared By:
Dave Cel I mer, P.E.
EquitySoec Consultilng Engineers, Inc.
4508 N. Sierra Way Suite 115
San Bernardino, CA 92407
(909) 881-7278
Job Nuinber: CITY OF LA QUINT..'
I . BUILDING & SAFETY DEP"
03025
APPROVED
FOR CONSTRUCTION
Date:
DATE* BYZ!
10/12/2003 7b-77,2 /it
The En6rj'yPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency -Standards.
This program developed by Ener gySoft, LLC (415) 883-5900.
'EnergyPro 3.1 By EnergySoft Job Number: 03025 User Number: 4582
lot cs
CON
N
TABLE OF CONTENTS
Cover Page
Table of Contents
Nonresidential Performance Title 24 Forms
Form ENV-M,M Envelope Mandatory Me6sures
Form MECH-MM Mechanical Mandatory -Measures
1
2
3
12
13
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1
!PROJECT NAME
Lamppost Pizza and Backstreet Brewery
,PROJECT ADDRESS
One Eleven La Quinta Center La Quinta
PRINCIPAL DESIGNER - ENVELOPE
Carl Cox, A.I.-A. Architect
00CUMENTATION AUTHOR
I EquitySpec Consulting Engineers, Inc.
TELEPHONE
760-347-4007
TELEPHONE
(909) 881-7278
DATE
10/12/2003
Building Permit #
Checked by/Date
Enforcement Aciencv Use
lGENERAL INFORMATION
I
DATE OF PLANS it), 1+0 IBUILDING CONDITIONED FLOOR AREA
-4-194k�
5,33OSq CLIMATE ZONE 15
Ft.
BUILDING TYPE X1 NONRESIDENTIAL
HIGH RISE RESIDENTIAL E] HOTEL/MOTEL GUEST ROOM
PHASE OF CONSTRUCTION [X] NEW CONSTRUCTION
E] ADDITION F-1
ALTERATION EXISTING + ADDITION
is Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and
of the State Building Code. This certificate applies only to a BuiIdi9&'th5iA',The� performance compliance approach.
I nnwin (,nIr-nnr 1--) 97
DATE
IN I & -.-2
The Principal Designers hereby certify that the proposed building design represented in the construction document�;nd m'od W-1
for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this
permit application. The proposed building as designed meets'the energy efficiency requirements of the State Building Code, Title
124, Part 6.
ENV. LTG. MEC
F-]F—sign thisxbLument as the person responsible for its preparation; and that I am licensed as a civil engineer,
L —1 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
CZ;6-c�aniical engineer,3ectrical engineer or architect.
2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor preparing documents for work that I have'contracted to perform.
F-1 F-1 17 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pusuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in
full in the Nonresidential Manual.)
JENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Require
I � �0 s E Njq/1'
PRINCIPAL ENVELOPE DESIGNER - NAME SIG C 0 QnT E
Carl Cox, A.I.A. Architect IX I
ILIGHTING COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures ILighting Compliance Not In The Scope Of
Required Forms FThis�-S'ubm-iftal
PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE
IMECHA NICAL COMPLIANCE —7
IIndicate location on plans of Note Block for Mandatory Measures
Required Forms IMEQH 1 1, MECH-2, MECH-3 -
PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE JILIC NO. DATE
'�Equ#tySpec Consultin En ineers., In
lEnergyPro 3.1 By EnergySoft User Number: 4582 Job Number: 03025 Page: 3 of 14
PERFORMANCE C.ERTIFICATE OF COMPLIANCE faft 2 of 3 PERF -11
DATE
Lamppost Pizzaand Backstreet br'6"w'ery 10/12/
ANNUAL SOURCE ENERGY USE SUMMARY, (IkBtu/sqft-yr)�
Standard
Proposed
1 Compliance
ENERGY COMPONENT
Design
Design
Margin
ffflffi.-.di�aZ�� mtp----
Space Heating
3.43
0.68
-Q
Space Cooling
82.63
61.58
21.05
11ndoor Fans
40.19
48.41
-8.22
_2 x
Heat Rejection
0.00
0100
i 0.00
g�g
Pumps & Misc.
0.00
0.00
0.00
Domestic Hot Water
0.00
0.00
0.00
Lighting'
38.67
38.67
0.00
00
Receptacle
14.52
14.52
0.00
Process
0.00
0.00
0.00
-191
MM
10INTIM A 'i
TOTALS;
179.44
165.93
13.51
0"S"BRO-61R.-ML
LO
BUILDING
COMPLIES
GENERAL INFORMATION
Building Orientation (North) 0 de� Conditioned Floor Area 5,330 sqft.
Number of Stories 11 Unconditioned Floor Area 0 sqft.
..Number of Systems 6 Conditioned Footprint Area 0 sqft.
Number of Zones
Orient.a.tion Gross Area Glazing Area Glazing Ratio
Front Elevation i
(North) 1,080 sqft. 162 sqft. 15.0%
Left, Elevation (East) 810 sqft. �324 sqft. 40.0%
Rear Elevation (South) 1,080 sqft. 0 sqft. 0.0%
Pight Elevation (West) 36 sqft. 1201 sqft. 27.5%
Total sqft. 6061 sqft.
Roof sqft. sqft.
Standard Proposed
Lighting Power Density 1.314 'Nlsqft. 1.314 W/sqft.
Prescriptive Env. Heat Loss 836� 783
Prescriptive Env. Heat Gain 97,172 98,124
Remarks:
Run Initiation Time: 10/12/03 13:38:46 Run Code: 1065991126
Energypro 3.1 By EnergyS. ft User Number: 4582 - Job Number: 03025 PageA of 14
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1
PROJECT NAME
Lamppost Pizza and Backstreet Brewery
DATE '
10/12/2003
IZONE INF5—RMATION
Sys - tem Name Zone Name Occupancy Type
Floor
Area
(sqft.)
Inst.
LPD
(W/sf)l
Port.
LPD
(W/Sf)l
Ctrl. Tailored
Credits LPD
(W/Sf)2 (W/So 3
Proc.
Loads
(W/Sf)
HP -1 Dining north HP -1 Dining Area
1,000
*1.100
HP -2 Dining west HP -2 Dining Area
930
*1.100
HP -3 Dining east -- HP -3 Dining Area
500
*11.100
HP -4 Interior HP -4 Dining Area
1,000
*1.100
HP -5 Kitchen HP -5 Kitchen & Food Prep
1,000
*1.700
HP -6 Kitchen and Brewery HP -6 Kitchen & Food Prep
900
*1.700
Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3
I
3. See LTG -4
Items
I
above require special
documentation
1EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
T1,- 1-1 --9
'-j — -- f--.7 --9 ILI ". I — L I � L— I� I PMAIMILI III L111b W11OUK115E. i nese nems require special written
justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines
---.y —J— IU11 L910L VLIIVIWMU ILVIII1JIIt:b UdtjUU Un Ene auequacy oT Tne sp cia ius i ication
and documentation submitted. I �Ian Field
The HVAC System "Bryant 549BEX090" includes an Economizer. This system has a cooling output < 75,000 btuh or a supply cfm < 2 �00.
The HVAC System "Bryant 549BPX060" includes an Economizer. This system has a cooling output < 75,000 btuh or a supply cfm < A
The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and
documentation for their use have been provided by the applicant.
Authorized Signature or Stamp
Kun initiation lime: 10/1 Z/Q3 13:38:46 Run Code: 1065991126
3.1 By EnergySoft User Number: 4582 Job Number: 03025 Page:5 of 14
JENVELOPE COMPLIANCE SUMMARY Performance EN:V]-1
��ECT 14AME
Lamppost Pizza and Backstreet Brewery
DATE
10/12/2003
OPAQUE SURFACES
Glazing Type
Location Comments
1 Window
60 0.720
270
0.60
Double Metal Tinted Default
Surface Framing
d4 Type Type
Act.
Area U -Fac- Azm.
Tilt
Solar
Gains
Y/N Form 3 Reference
Location'/ Comments
1 Wall
Wood
150
0.065
270
90
1X1 IR-19Wall
(W.19.2x6.16)
HP -1
2 Wa—llW—ood
90
918
0.065
0 —
90
IXI IR-19Wall
(W.19.2x6.16)
HP -1
3 Wall
Wood
210
0.065
90
90
1X1 IR-19'Wall
(W.19.2x6.16)
HP -11
4 Roof
Wood
1,000
0.031
0
0
IX I
R-30 Roof(R.30.2x4.24)
HP -1
5 Wall
Wood
150
0.065
270
90
X I
R-1 9 Wall (W. 1 9.2x6.16)
HP -2
6 Roof
Wood
930
0.031
0
0
X
R-30 Roof(R.30.2x4.24)
HP -2
7 Wall
Wood
210
0.065
180
90
R-19 Wall (W.19.2x6.16)
HP -3
8 Wall
Wood
138
0.065
90
90
x
1
R-19Wall (W.19.2x6.16)
HP -3
9 Roof
Wood
500
0.031
0
1 0
X
R-30 Roof(R.30.2x4.24)
HP -3
10 lWall
lWood
210
1 0.065
180
90
X
R-19 Wall (W.19.2x6.16)
HP -4
11 Poof
lWood
1,000
1 0.031
0
0
X
R-30 Roof(R.30.2x4.24)
HP -4
12 lWall
Wood
500
0.065
180
90
X11 JR-19Wall
(W.119.24.116)
HP -5
13 Wall
Wood
16
0.065
270
90
X I IR-19Wall
(W.19.2x6.16)
HP -5
14 Roof
Wood
1,000
0.031
0
0
X I I
R-30 Roof(R.30.2x4.24)
HP -5
15 Wall
Wood
160
0.065
180 1
90
_X JR-19Wall
(W.19.2x6.16)
HP -6
16 Wall
Wood
138
0.06�
90
90
X
R-19Wall ( .19.24.16)
HP -6
17 Roof
Wood
900
0.031
0
0
R-30 Roof(R.30.2x4.24)
HP -6
FENESTRATION SURFACES
— — . .
. . .
__j
Site Assembled Glazing [_j 1111CLA UVA 1 DU 1U 119 ib — iuu,uuv squ OT L.FA ana — iu,uuu sqrt verticai glazing then NFRC Certification is required.
Fnllnw NF�lr 11n1n'-SR procedurac on't C"I'Mif KIP!Dr, 1 k 1 e, �;C 4 C
# Type
Area U -Fac. Act. Azm.
SHGC
Glazing Type
Location Comments
1 Window
60 0.720
270
0.60
Double Metal Tinted Default
-lP-1
2 Window
162 0.720
0
0.60
Double Metal Tinted Default
-iP-1
3 Window
60 0.720
27b
0.60
Double Metal Tinted Default
-P-2
4 Window
162 0.720
90
0.60
Double Metal Tinted Default
-P-3
5 Window
162 0.720
90
0.60 1
Double Metal Tinted Default
HP -6
EXTERIOR SHADING
# Exterior Shade Type
SHGC
Window
Hgt. Wd.
Overhan_q Left Fin Right Fin
Len. Hat. LExt.RExt. Dist. Len. Hgt. Len. Hgt.
1 None
0.76
---DList.
2 None
0.76
3 None
0.76
4 None
0.76
5 None
0.76
Run Initiation Time: 10/12/0313:38:46 Run Code: 1065991126
EnergyPro 3.1 By EnergySoft
User Number: 4582
Job Number: 03025
Page:6 of 74
CERTIFICATE OF COMPLIANCE Performance MECH
PROJECT NAME Lamppost Pizza and Backstreet Brewery —[DATEJ 0/12/2003
FSY-STEM FEATURES
ISYSTEM NAME I
TIME CONTROL
SETBACK CONTROL
ISOLATION ZONES
HEAT PUMP THERMOSTAT?
ELECTRIC HEAT?
FAN CONTROL
VAV MINIMUM POSITION CONTROL?
SIMULTANEOUS HEAT/COOL?
HEATING SUPPLY RESET
COOLING SUPPLY RESET
HEAT REJECTION CONTROL
VENTILATION
OUTDOOR DAMPER CONTROL
ECONOMIZER TYPE
DESIGN O.A. CFM (MECH-3, COLUMN 1)
HEATING EQUIPMENT TYPE
HEATING EQUIPMENT EFFICIENCY
COOLING EQUIPMENT TYPE
COOLING EQUIPMENT EFFICIENCY
MAKE AND MODEL NUMBER
PIPE INSULATION REQUIRED?
PIPE/DUCT INSULATION PROTECTED?
HEATING DUCT LOCATION I R -VALUE
COOLING DUCT LOCATION1 R-VALU
VERIFIED'SEALED DUCTS IN
CEILING/ROOF SPACE
MECHANICAL SYSTEMS
HP -1 Dining north HP -2 Dining west I I HP -3 ining east
Programmable Switch
Heating & Cooling Required
n/a
Yes
0.0 kW
Constant Volume
No
No
Constant Temp
Constant Temp
n/a
Air Balance
Auto
Fixed Temp (Integrated)
300 cfm
Heat Pump
7.20 HSPF
Packaged DX
10.3 EER
Bryant 549BEX090
No
No
Ducts in Conditioned
n/a
Ducts in Conditioned
n/a
No
Programmable Switch
Heating & Cooling Required
n/a
Yes
0.0 kw
Constant Volume
No
No
Constant Ternp
Constant Temp
n/a
Air Balance
Auto
Fixed Temp (Integrated)
279 cfm
Heat Pump
7.60 HSPF
Packaged DX
11.9 SEER / 11.9 EER
Bryant 549BPX060
No—
No
Ducts in Conditio
n/a
Ducts in Conditio
n/a
No—
Programmable Switch
Heating & Cooling Require
n/a
Yes
0.0 kW
Constant Volume
No
No
Constant Temp
Constant Temp
nia
Air Balance
Auto
Fixed Temp (integrated)
150 cfm
Heat Pump
7.60 HSPF
Packaged Dx
11.9 SEER / 11.9 EER
Bryant 549BPX060
No
No
Ducts in Conditioned
n/a
Ducts in Conditioned
n/a
No
NOTETO
FIELD__
Run Initiation Time: 10/12/03 13:38:46 Run Code: 1065991126
EnergyPro 3.1 By EnergySoft User Number: 4582 . Job Number: 03025 Page: 7 of 14
CODE TABLES: Enter code from table below into columns above.
HEAT PUMP THERMOSTAT?
Y: Yes
N: No
TIME CONTROL
SETBACK CTRL.
ISOLATION ZONES
FAN CONTROL
ELECTRIC HEAT?
S: Prog. Switch
0: Occupancy
Sensor
M: Manual Timer
H: Heating
C: Cooling
B: Both
Enter Number of
Isolation Zones.
1: Inlet Vanes
P: Variable Pitch
V: VFD
0: Other C: Curve
VAV MINIMUM POSITION CONTROL?
SIMULTANEOUS HEAT / COOL?
HEAT AND COOL SUPPLY RESET?
VENTILATION
OUTDOOR DAMPER
ECONOMIZER
O.A. CFM
HIGH EFFICIENCY?
B: Air Balance
C: Outside Air Cert.
M: Out. Air Measure
D: Demand Control
N: Natural
A: Auto
G: Gravity
A: Air
W: Water
N: Not Required
EC: Economizer
Control See Section
144(e)3
Enter Outdoor Air
CFM. 'no
Note: This shall be
less than Col. H on
MECH-3.
PIPE INSULATION REQUIRED?
PIPE/DUCT INSULATION PROTECTED?
SEALED DUCTS IN CEILING/ROOF SPACE
__jj
.INOTES TO FIELD - For Buildina Department Use Only
Run Initiation Time: 10/12/03 13:38:46 Run Code: 1065991126
EnergyPro 3.1 By EnergySoft User Number: 4582 . Job Number: 03025 Page: 7 of 14
CERTIFICATE OF COMPLIANCE Performance MECH-1
PROJECT NAME DATE
Lamppost Pizza and Backstreet Brewery 10/12/2003�1
FS-YSTEM FEATURES
MECHANICAL SYSTEMS I
HP -4 Interior I I HP -5 Kitchen I I HP -6 Kitchen and Brewery
Programmable Switch
Heating & Cooling Required
n/a
Yes
0.0 kW
Constant Volume
No
No
Constant Temp
Constant Temp
. n/a
Air Balance
Auto
Fixed Temp (Integrated)
740 cfm
Heat Pump
7.60 HSPF
Packaged DX
11.9 SEER / 11.9 EER
Bryant 549BPX060
No
No
Ducts in Attic 4.2
Ducts in Attic
No
Programmable Switch
Heating & Cooling Required
n/a
Yes
0.0 kW
Constant Volume
No
No
Constant Temp
Constant Temp
n/a
Air Balance
Auto
Fixed Temp (Integrated)
75 cfm
Heat Pump
7.20 HSPF -
Packaged DX
10.3 EER
Bryant 549BEX-090
No
No
Ducts in Attic 4.2
Ducts in Attic 4.2
No—
Programmable Switch
Heating & Cooling Require
n/a
Yes -
0.0 kW
Constant Volume
No
No
Constant Temp
Constant Temp
n/a
Air Balance
Auto
Fixed Temp (Integrated)
45 cfm
Heat Pump
7.60 HSPF
Packaged DX
—11.9 SEER / 11.9 EER
Bryant 549BPX060
No
No
Ducts in Attic 4.2
Ducts in Attic 4.2
No
NOTE TO,
FIELD
CODE TABLES: Enter code from table below into columns above. I
HEAT PUMP THERMOSTAT?
Y: Yes
N: No
—TIME CONTROL
SETBACK CTRL.
ISOLATION ZONES
FAN CONTROL
ELECTRIC HEAT?
S: Prog. Switch
0: Occupancy
Sensor
M: Manual Timer
—
H: Heating
C: Cooling
B: Both
Enter Number of
Isolation Zones.
1: Inlet Vanes
P: Variable Pitch
V: VFD
0: Other C: Curve
VAV MINIMUM POSITION CONTROL?
SIMULTANEOUS HEAT/ COOL?
HEAT AND COOL SUPPLY RESET?—
VENTILATION I
OUTDOOR DAMPERI
ECONOMIZER
O.A. CFM
!A_i�r
HIGH EFFICIENCY?
�B Air Balance I
A: Auto JA:
Air JEnter
Outdoor
PIPE INSULATION REQUIRED?
Outside Air Cert.
Out. Air Measure
Demand Control
N- Natural
G: Gravity
W: Water
N: Not Required
EC: Economizer
Control See Section
CFM.
Note: This shall be no
less than Col. H on
MECH-3.
PIPE/DUCT INSULATION PROTECTED?
SEALED DUCTS IN CEILING/ROOF SPACE'o
_j
144(e)3
-JTFq TO FIFI r) - P -r R,dirlinn
Run Initiation Time: 10/12/0313:38:46 Run Code: 1065991126
EnergyPro 3A By EnergySoft User Number: 4582 Job Number: 03025 Page:8 of 14
IMECHANICAL EQUIPMEN4 SUMMARY Part 1 of 2 MECH-72
PROJECT N . AME -La m I p I DATE,
-- __post Pizza and Backstreet Brewery 0/12/ZO03
AND TOWER SUMMARY
,ICHILLER
Efficiency
Au..
kW
0.01
PUMPS
I Out
76,0001
ISensiblel
62,0001,10.3
Equipment Name
Equipment'Type
ty.
Tot.
GPM
BHP
Motor
Eff.
Drive
Eff.
�u
Pump
Control
41,300111.9
SEER 11.9 EE
1 R
i
Fixed Temp (Integrated
i j
f
I QHW BOILER SUMMARY
TANKINSUD
Energy Factor
or Recovery
Efficiency
Standby
Loss or
Pilot
System Na me
System Type
Distri bution Type
(��j
Rated
Input
Vol.
(Gal s
Ex
. I
R -Val.
ICENTRAL SYSTEM RATINGS
Svstern Name
Bryant 549BEX090
S— e
y1tern Ty p
IPackaged DX
Qt,.
21
j Out. u
89,200
Au..
kW
0.01
Eff.
—pyt—I
7.20 HSPFI
I Out
76,0001
ISensiblel
62,0001,10.3
Efficienc y
EER
Economizer Type I
IFixed Temp (Int� U.0LUL
Bryant 549BPX060
IPackaged DX
41
59,3001
O.Oi
730 HSPFI
46,3001
41,300111.9
SEER 11.9 EE
1 R
i
Fixed Temp (Integrated
i j
Drive
Eff.
I
ICENTRAL SYSTEM FAN SUMMARY
—LY
CFM
1 2,2501
1 2,0001
FAN
11 F—RETURN FAN
S
Bryant 549BEXO 90
Bryant 549BPX060
Fan lype
Iconstant Volume
lConstant Volume
Motor Location
-- i -
IDraw-Through
h
BHP
1.001_.82.5%1
1.001
Motorl
Eff.
82.5%1
Drive
Eff.
97.0%11
97.0%1
CFM
none
nonel
I BHP
Motor
Eff.
I
Drive
Eff.
I
EnergyPro 3.1 By EnergySoft User Number: 4582 Job Number: 03025 Paqe:9 of 14 1
4
IMECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH 2]
PROJECT NAME Lamppost Pizza and Ba*ckstreet Brewery DFATE10/12/2003
ZONE TERMINAL SUMMARY
AL BOX ERMI AL FA14
CFM Reheat Coil Motor Drive
tio Type DeltaT CFM BHP Eff. Eff.
A
E A T AN
Room Name
-
Qty.
I CFM
I BHP
Motor
Eff.
Drive
Eff.
Room Name
Qty.
CFM
BHP
Motor
Eff.
Drive
Eff.
HP -4
11
7401
0.25
77 0
97.0%
EnergyPro 3.1 . By EnergySoft User Number: 4582 Job Number: 03025 Page: 10 of 14 1
�MECHANICAL VENTILATION MECH-3
PROJECT NAME I I DATE
Lamppost Pizza and Backstreet Brewe�y 10/12/2003
MECHANICAL VENTILATION
A] FP1 i[E FEI Ed E—H] E I Ri 5-1
K
FnergyPro 3.1 By EnergySoft User Number: 4582 Job Number: 03025 Paqe: 11 of 14
AREA BAS
S
; OCCUPANCY
ASIS
REQ'D
O.A.
(MAX OF
D OR G)
DESIGN
OUTDOOF
AIR
CFM
VAV
MIN.
RATIO
TRANS.
FER
AIR
ZONE/SYSTEM
COND.
AREA
(SF)
CFM
PER SF
MIN.
CFM
(B x C)
'NO.
OF
PEOPLEI
I CFM
PER
PERSON
MIN.
CFM
(ExF)
HP -1
1,000
0.50
500
500
300
200
HP -1 Dining north
Total
500
300
HP -2
930
0.50
465
465
279
186
HP -2 Dining west
Total
465
279
HP -3
500
0.50
250
250
150
100
HP -3 Dining east
Totall
250
150
HP -4
1,000
0.50
:550]0
500
740
.
HP -4 Interior
Total
500
740
HP -5
1,0001
.0.15
1501
150
75
75
HP -5 Kitchen
Total
150
75
HP -6
900
0.15
1.35
1
135
45
90
HP -6 Kitchen and Brewery
Total
135
45
-------------
C
E
I
K
Minimum Ventilation Rate per Section 121, Table 1-F.
Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density.
Must be ' greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans.
Must be greater than or equal to (H minus 1), and, for VAV, greater thar� or equal to (H -J).
FnergyPro 3.1 By EnergySoft User Number: 4582 Job Number: 03025 Paqe: 11 of 14
ENVELOPE MANDATORY MEASURES' ENV -MM
I
VKUJtk; I NAML Lamp DATE
post Pizza and Backstreet Brewe�y 10/12/2003
DESCRIPTION
Designer
jEnforcement
'118(a) Installed Insulating Material shall have been certified by t he manufacturer to comply
with the California Quality Standards for insulating material, Title 20, Chapter 4, Article
3.
]EX] § 118 (c) All Insulating materials shall be installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 767 of Title 24, Part 2.
1XI § 117(a) All Exterior Joints and openings in the building that , are observable sources of air
leakage shall be caulked, g�asketed, weatherstripped or oiherwise sealed.
116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except fo� unframed glass doors and
fire doors).
LLI,j § 116(a)l Manufactured Doors and Windows installed shall have air infiltration rates not
exce ' eding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products must be labeled for U -value according to NFRC procedures.
§118(e) Dernising Walls in 'Nonresidential Buildings:
The opaque portions of framed dernising walls in nonresidential buildings shall have
insulation with an installed R -value of no lessthan R-1 I between framing members.
Ene yPro 3.1 By EnergySoft User Number: 4582 Job Number: 03025 Page: 12 of 14
IMECHANICAL MANDATORY MEASURES Part 1. of 2 MECH-MM
PROJECT NAME Lamppost Pizza and Backstreet Brew� . ry DATE 10/12/200
DESCRIPTION II
Enforcement
Equipment and Systems Efficiencies
[_XI §111 Any.appliance for which there is a California standard !established in the Appliance
Efficiency Regulations will comply with the applicable standard.
1
§ 115(a) Fan type central furnaces shall not have a pilot light.
F] § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be insulated in accordance with
Standards Section 123.
124 Air handling duct systems shall be installed and insulated in compliance with
Sections 601, 603 and 604 of the Uniform Mechanical Code.
i
Controls
§ 122(e) Each space conditioning system shall be installed with one of the following:
IFv § 122(e)IA Each space conditioning system serving building type's such as offices and
manufacturing facilities (and all others not explicitly exempt from the requirements
of Section 112 (d)) shall be installed with an automatic time switch with an
accessible manual override that allows operation of the system during off -hours for
up to 4 hours. The time switch shall be capable of programming different
schedules for weekdays and weekends; incorporate an automatic holiday "shut-
off"feature that turns off all loads for at least 24 hours, then resumes the normally
scheduled operation; and has program backup capabilities that prevent the loss of
the device's program and time setting for at least 10 hours if power is interrupted;
or
122(e)l B An, occupancy sensor to control the operating period of the system; or
F -I 122(e)1C A 4- - hour timer that can be manually operated to control the operating period of the
system.
122(e)2 Each space conditioning system shall be installed with controls that temporarily
restart and temporarily operate the system as required to maintain a setback
heating and/or a setup c.poling thermostat setpoint.
122(g) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with isolation
zones. Each zone: shall not exceed 25,000 square feet; shall be provided with
isolation devices, such as valves or dampers, that allow the supply of heating or
cooling to be setback or shut off independently of. other isolation areas; and shall
be controlled by a time control device as described above.
fvl 122(a&b) Each space conditioning system shall be controlled by an individual thermostat
'At
that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the control
shall be adjustable up'to 85 degrees F or higher. Where used for both heating and
cooling, the control shall be capable of providing a deadband of at least 5 degrees
F within which the supply of heating and cooling is shut off or reduced to a
minimum.
FX 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable
setpoint stops accessible only to authorized personnel.
1! 17 § 112(b) Heat pumps shall be installed with controls to preventelectric resistance
supplementary heater operation when the heating load can be met by the heat
pump alone.
EnergyPro 3.1 By EnergySoft User Number: 4582 I Job Number: 03025 Page: 13 of 14
I
MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM
F-UTNAME
Lamppgst Fizza and Backstreet B
DATE
10/12/2003
Description
er
IlEnforcement]
Ventilation
JX, § 121(,) Controls shall be provided ' to allow outside air dampeis or devices to be operated at
the ventilation rates as specified on these plans. i
X] § 122(f) Gravity or automatic dampers interlocked and closed ?In fan shutdown shall be
provided on the outside air intakes and discharges of all space conditioning and
exhaust systems.
§ 122( All gravity ventilating systems shall be provided with automatic or readily accessible
manually operated dampers in all openings tothe outside, except for combustion air
openings.
[X § 121(f)l Air Balancing: The system shall be balanced in accordance with the National
'Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1989); or
FV_I
JAI 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be me s'ured and certified by the
installing licensed C-20 mechanical contractor and%rtified by (1) the design
mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the
person with overall responsibility for the design of the' I ventilation system; or
F� § 121(03 Outside Air Measurement: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity.of outside air on a continuous
basis and displaying that quantity on a readily accessible display divice; or
§.121(04 Another method approved by the Commission.
Service Water Heating Systems
§ 113(b)2 if a circulating hot water system is installed, it shall have a control capable of
automatically turning off the circulating pu mp(s) wheri-hot water is not required.
F -I § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the
outlet temperature to 110 degrees F.
§ 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the
following:
Outlet devices that limit - the flow of hot water to a maxi 'mum of 0.5 gallons per
minute.
'Foot actuated control valves, and outlet devices that limit the flow of hot water to a
maximum of 0.76 gallons per minu te.
Proximity sensor actuated control valves, and outlet de'�ices that limit the flow of hot
water to a maximum of 0.75 gallons per minute.
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.25 gallons/cycle (circulaiting system).
Self-closing 4ves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.50 gallons/cycle (non-ci,rculating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.75 gallons/cycle (foot s -witches and proximity sensor
controls). -
EnergyPro 3.1 By EnergySoft User Number 4582 Job Number: 03025 Page: 14 of 14
bb -A
02/07/2005 12:52 7147777773 INLAND ENG PAGE 01
y
x
6.453k
Loads. LC 2, DL+LL4-LAT
Resufts for LC 2, DL+LL+LAT
Reaction units are k 6nd k -ft
Inland Engineering, Inc.
REZA MEHRANPOUR
03616
LAMPPOST PIZZA
I
February 7. 2005
12:44 PM
FRAME 92-r2d
02/07/2005 12:52 7147777773 INLAND ENG PAGE 02
Company Inland Engineering, Inc. February 7, 2005
Designer REZA MEHRANPOUR 12:43 PM
Job Number: 03616 LAMPPOST PIZZA Checked By:
Member ASO AISI 99 Code Checks, By Combination
LC Member Label Code Chk Loc Shear Chk Loc ASD Eqn. Message
Data to Print... . .....
Basic Load Case Data
BLC No. Basic Load Case Category
LL
Boundary Condhions
Joint Label X Translation Y Translation Rotation
Reaction
Gravity Load Type Totals
Y Joint Point Direct Dist
Steel Design/ NDS ParafflefeM
Member Section Length Lb out Lb in L comp Cb $way
Label set Is out to in le–bend K out K in CH Cm 5 out in R
Iftl (ft) (ft) (ftl
F- M1
SEC1 1
Allowable Stress Increase Factor (ASIF)
1.333
InrAude Shear Deformation
0.
I M2
SECI 1
,Redesign Sections
Yes
1P-Defta_Ana!)TLs Tolerance
10,50%
F- M3
SEC2.__ I
Member Direct Distributed Loads, Catemoty: DL, BLC I : DL
Member Label Dinaction start Magnitude End Magnitude Start Location End Location
(kft F) (ft or %)
D (ft or %)
Y -.24 1 0 1 0
Member Direct Distributed Loads. Catecorv: LL. BLC 2., LL
Member Label obwtion Start Magnitude End Magnitude Start Location rind Location
(lofft, F) (ft or %) (ft or
0 0
Materials Menem
Material Label Young's Modulus Shear Modulus Polason's Thermal CwL Weight Density Y-wid Stress
(ksi) Ratio per 1 DA5 F) (kW3) ft
F 29000 1 11154 1 .3 .65 .49 —T---'36---]
Global
Steel Code
ASD: AISC 9th, AlSl 99
Allowable Stress Increase Factor (ASIF)
1.333
InrAude Shear Deformation
Yes
No. of Sections for Member CaIcs
3
,Redesign Sections
Yes
1P-Defta_Ana!)TLs Tolerance
10,50%
RISA -2D Basic Ver5lon S.S [C*\RISA\JOBS-03kCOMMERICAL\03616\FRAME #2.r2d] Page I
02/07/2005 12:52 7147777773
INLAND ENG
PAGE 03
Company Inland Engineering, Inc. February 7, 2005
Designer REZA MEHRANPOUR 12:43 PM
Job Number: 036 16 LAMPPOST PIZZA Checked By:
joint Coordinates
Joint Label X Coordinate Y Co6dinato Joint Temperature
/a% fff% 1171
N1
0
0
0
N2
0
9
0
N3
10
0
0
N4
10
9
0
Joint Disp
Lacements, By Combination
LO joint Label X Translation Y Tronslat * an Rotation
A-% 1;�% fr2dinnrA
2
N1
0
0
0
2
N2
.503
a
-2.157e-3
2
N3
0
0
0
2.
N4
'501
--.007
-1.335e-4
Joint LoadsAEnforced Displacements, Q0go"; DL, BLC I - DL
Joint Label [L]oad or Direction Magnitude
N4
L
Joint LoadstEnforced Displacements, Category : LL, SLC 2 - LL
Joint Label [Lload or Directlon Magnitude
N4
Joint Loads)Enforced Displacemenft, Cafeaory: EL, BLC 3: LAT
Joint Label [Qoed or Direction Magnitude
N2 --..-JPJisp cement x (K L -t in radl--,
Reactions e
-c By Combination
LC Joint Label X Force Y ro, Moment
Load Combinations
Num Description Env WS PD CD BLC Factor BLC Factor BLC Factor BLC Factor
I I I DL+LL y I I 1 1 1 6[7 1 1 1 LL 1 1 1
1 2 1 UL+LL+LAT " I- Y I 1 1 1 DL 1 1 1 LL I I I EL I I I I I
Matedal rakeoff
Matarial Shape Length Weight
(ft) (k)
RISA -21) Basic rsion 5.5 [C:\RISA�jOBS-03\COMMERICAL\03616\FRAME #2.r2d] Page 2
k)
M (k -ft)
2
N1
-2.834
1.801 14.058
2
N3
-3.619
16.232 16.364
2
Totals:
-6.453
18.033
2
COG (ft):
X: 7.468
Y, 8.872
Load Combinations
Num Description Env WS PD CD BLC Factor BLC Factor BLC Factor BLC Factor
I I I DL+LL y I I 1 1 1 6[7 1 1 1 LL 1 1 1
1 2 1 UL+LL+LAT " I- Y I 1 1 1 DL 1 1 1 LL I I I EL I I I I I
Matedal rakeoff
Matarial Shape Length Weight
(ft) (k)
RISA -21) Basic rsion 5.5 [C:\RISA�jOBS-03\COMMERICAL\03616\FRAME #2.r2d] Page 2
02/07/2005 12: 52 7147777773 INLAND ENG PAGE 04
Company Inland Engineering, Inc. February 7, 2005
Designer REZA MEHRANPOUR 12:43 PM
Job Number: 03616 LAMPPOST PIZZA Checked By:
Matedal Takeoff Lconfinuegi
Member Deflegfons
.1 & Combination
LC member Label Section x -Translation y -Translation (n) Uy Ratio
1;-% A�%
1 - -----------
2:::F M1
0
0
NC
2
0
-.222
485.578
3
0
-.503
214.683
M2 1
0
0
NC
2
-.004
-.249
434.472
3
-.007
-.501
215.572
2 M3 1
.503
0
NC
2
.602
-.046
2878.553
3
.501
-.007
1 NC
Member Section Forces, By Combination
LC Member Label Section A)dal Shear Moment
(ki W (k -ft)
2 M1 1
1.801----
2.834
14.058
2
3
1.673
1.545
2.834
2.834
1.303
-11.452
2 M2 1
16.232
3.619
16.364
2
16.104
3.619
.081
3
1$.976
3.619
-16.203
2 M3 1
3.619
1.545
-11.452
2
3,619
-2.765
-8.4
3
3.619
-7.076
16.203
Member Stresses, By Combination - V
LC Member Label Section Axial Show Bending top Bending bot
(kai) (ksi) (k9i (ksi)
2 N111 1
.215
.68
-15.62
1 15.62
2
.2
.68
-1.448
1,448
3
.185
68
12.724
-12.724
2 1
1.942
.868
-18.183
18.183
2
1.926
.868
-.09
.09
3
1.911
1 .868
18.003
-18.003
2 M3 1
.558
.76
5.922
1 -5.922
2
.558
-1.36
1 4.1"
-4.344
3
.558
-1.
MemberData
shape I Material Phys End Releases End Offset; Inactive
Member Label ' I Joint J Joint Rotate Section Set Memb I -End J -End I -End J -End Code Length
4
__ 7
RMA -W Basic Version 5.5 [C:\RISA\.JOBS-03\COMMERICAL\03616\FRAME #2.r2d] Page 3
02/07/2005 12: 52 7147777773 INLAND ENG PAGE 05
Febnja%7, 2005
Company Inland Engineering, Inc.
Designer REZA MEHRANPOUR 12:43 P
Job Number: 03616 LAMPPOST PIZZA Checked By --
Sections
Per -Ann Datab298 Material Ar" SA SA 1(9O.Z70)
MernberAISC ASD 9th Code Checks, By Combination
LC Member LaW Code Chk 1.00 Shear Chk Loc ASD Eqn. Message
Member AISC ASD 9th Code Details, ft Combination
LC Member Label Fa Ft rb Cb CM
RISA -2D Basic Verslon� 5.5 [C:\R1SA\J08S-03\C0M_ -ME_R_lCAL\03616\FRAME #2.r2d) PaQ;1_4
I Project: Lamp Post Pizza Type: C1
C -r Bivillms Location: La Quinta, CA Qty: 10
TJ-0penWeb- v4.21.1 Release: R1 Project Number: SC06J04008
i 1 /9/2004 4:16:37 PM PAGE 1' Rel. Desc.: Roof
THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED
Reference Span = 18'6.000"
0.25"
T 3.00"
14.000" TJLXTM OPEN WEB TRUSS
_7.
Parallel Profile
11A
5.2 5- 5.25"
7_1
Top Chord Slope -.25/12
0,75" 0.75"
All dimensions are horizontal.
TJ-0penWeb, TJ " and Trus JoIst",
ate lr@de
Product diagram is conceptual.
LOADS:
DATE
77
Analysis for Open -web Member Supporting ROOF Structural
Classification.
Loads (psf): 20 Roof at 125% duration, 18 Dead (top
chord), 0 Dead (bottom
chord), @
24.000" O.C. and:
LOAD GROUP #1 @ 24.000" O.C.-Wind load
TYPE CLASS LIVE DEAD
LOCATION (1)
APP L
APPLIED TO
COMMENT
Point(plf) W(I.33) -54 0
4'0.000"
Addsto
TC, on chord(s)
Wind load from parapet
Uniform(psf) W(1.33) -24 11.7
4'0.000" to 16'10.188" Replaces
TC
Wind uplift
LOAD GROUP #2 @ 24.000" O.C.-Typical truss
TYPE CLASS LIVE DEAD
LOCATION (1)
APPIL
APPLIED TO
COMMENT
Point(plf) W(1.33) 54 0
4'0.000"
Addsto
TC, on chord(s)
Wind load from parapet
Point(lbs) R(1.25) 0 30
T0.000"
Adds to
TIC, on chord(s)
Load per
fl't*S�f
LOAD GROUP #3 @ 24.000" O.C.- ' Parapet load (parallel)
CJJM1;F-15
TYPE CLASS LIVE DEAD
LOCATION (1)
APPL
APPLIED TO
COMMENT
Point(plf) W(1.33) 54 0
4'0.000"
Adds to
TC, on chord(s)
Wind load from parapet
Uniform(plf) W(1.33) 54 0
4'0.000" to 18'5.625"
Adds to
TIC
Wind load from parapet
Point(lbs) R(1.25) 0 30
LOAD GROUP
T0.000"
Adds to
TC, on chord(s)
Load per
#4 @ 24.000" O.C.-Strap load (check)
I
TYPE CLASS LIVE DEAD
LOCATION (1)
APPL
APPLIED TO
COMMENT
Strap(lbs) E(I.33) 2580 0
Right End
Addsto
TC
Due to strap load
1) Location is specified from left reference point unless noted otherwise.
SUPPORTS: LEFT SUPPORT (Angle: Oo)
RIGHT SUPPORT (Angle: 0')
Material: Wo6d Beam
Material:
Wood Beam
Bearing Clip: 6" No -Notch
Bearing Clip:
6" No -Notch
Reinforcement: Chord(s) only
Reinforcement: Chord(s) only
DE'SIGN CONTROLS:
Truss Member's Critical Design Component Value: 86.2% (Design / Allowable)
A repetitive member increase was applied to applic�tion load group and @ load group(s): 1, 2, 3. 4!
Truss design includes consideration for partial span application live load.
REACTIONS: LEFT MAXIMUM LEFT MINIMUM RIGHT MAXIMUM
Total Load (lbs) 7157 W (1.33) -133 W (1.33) 827 W (1.33)
Live Load (Ibs) 395 -358
DEFLECTIONS & CAMBER: CITY OF LA QUINTA
Deflection (Total Load) Span: 0.271" (L/786) BUILDING &SAFETY DEPT.
Deflection (Live Load) Span: 0.16i" (L/1323) APPROVED
Center Span Camber: 0. 135",. Matched to C2 FOR CONSTRUCTION
Cop,;ight Q 2002 by Trus Joist TJLX".
TJ-0penWeb, TJ " and Trus JoIst",
ate lr@de
DATE
77
Busineis, Boise. Idaho,
ff it
0��,fw
Project: Lamp Post Pizza Type: C1
15;VWA\*Ycrhae'user Busineg
TJ-0peiiWebUl v4.21.1
11 /9/20(14 4:16:37 PKA PAGE 2
ADDiTiONAL NOTES:
-IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). Allowable prodlict
values shown are in accordance with current TJ materials and code accepted design values. TJ. Engineerii ig has verified
the analysis. The input loads �an'd dimensions have been provided by others and must be verified and approved for the specific
application by the design professional for the project. Truss design values have been accepted by the following ag encies:
NES Rc ' oort No. NER-148, ICBO ES Report No. PFC-4354, LAC RR 22614, and DSA.
-Allowablu Stress Design methodology was used for Code ICBO analyzing the TJ Custom products listed above with
chords analyzed using Don Sharp's analysis.
-Pricing Load = 85.8 plf
OPERATOR INFORMATION
Henry Navarro
(949)885-5927
copyright @ 2002 by Trus Joist TJLX'", TJ-01)enWeb `. TJ - and Trus joist'" are trademarks of Trus Joist, A Weyerhaeuser BUsiness, Boise, Icialio, USA,