05-1070 (AR) Title 24I TITLE 24 REPORT Title 24 Report for: Ken Phillips 44-445 Camino Lawanda La Quinta, Ca 92253 Project Designer: Wade Ritchie Palm Springs, CA 760.808.1446 Report Prepared By: Mike King Mike King Company D m n 28295 Avenida La Paz #3 o� .. Cathedral City, CA 92234 N 0 ,.-u z (760) 322-6123 W p.0 G)O !o n C<V rn G z0 mZ Job Number: .> 0050 Date: 5/10/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. I__ EnergyPro 3.1 By EnergySoft Job Number: 0050 User Number: 5672 l I TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form C -2R Computer Method Summary 2 3 5 I EnergyPro 3.1 By EnergySoft Job Number. 0050 User Number: 5672 Certificate of Comoliance: Residential (Part 1 of 2) CF -1 R Ken Phillips 5/10/2005 Project Title Date 44-445 Camino Lawanda La Quinta Project Address Building Permit # Mike King Company (760) 322-6123 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 358 fl? Average Ceiling Height: 8.0 ft Total Conditioned Slab Area: 358 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Tvae Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof R-13 Wall (W.13.2(4.16) Wood 0.088 Exterior Wall Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins S U- actor SHGC Shading Yes / No Yes / No Front 30.0 0.60 0.53 Bug Screen x❑ ❑ x❑ ❑ Front 50.0 0.60 0.53 Bug Screen ❑ x❑ ❑ x❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El El El F-1 El El ❑❑ F] El El F1 El El F1 1:1 El El 1:1 El El Ed Run Initiation Time: 05/10/05 10:36:08 Run Code: 1115746568 Ener Pro 3.1 By Ener oft User Number: 5672 Job Number: 0050 Pa e:3 of 7 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Ken Phillips 5/10/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Equipment Minimum Distribution HeatingType and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Cooling Equipment Minimum Type (air conditioner, Efficiency heat pump, evap. cooling) (SEER) Duct Location Duct Thermostat Location/ (attic, etc.) R -Value Type Comments WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value 1 For small gas storage (rated inputs of less than or equal to 75,000 Btuthr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,0130 Btufhr); list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Mike Kng Title/Firm: Wade Ritchie Title/Firm: Mike Kng Company Address: Address: 28295 Avenida La Paz #3 Palm Springs, CA Cathedral City, CA 92234 Telephone: 760.808.1446 Lic. #:� (signature) (date) Enforcement Agency Name: Title/Firm: _ Address: Telephone: Telephone: (760) 322-6123 dr (signature) date) IEnergvPro 3.1 By EnergvSoft User Number. 5672 Job Number. 0050 Page:4 of 7 1 Comouter Method Summary (Part 1 of 3) C -2R Ken Phillips 5/10/2005 Project Title Date 44-445 Camino Lawanda La Quinta Project Address Building Permit # Mike King Company (760) 322-6123 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 3.30 Facing North Margin ❑ Facing East Margin Wall 179 0 088 a go Wall 100 0088 0 Facing South Margin ❑ ❑ El Facing West Margin 2.61 0.69 0.50 2.80 0.18 3.12 1.47 1.84 Space Cooling 64.27 48.18 16.09 65.39 -1.12 57.58 6.70 58.06 6.21 Domestic Hot Water 50.58 0.00 50.58 F-1 0.00 50.58 ❑❑ ❑❑ 0.00 50.58 0.00 50.58 50.79 67.36 65.90 52.25 57.75 60.39 59.53 58.62 Totals 118.15 El Run Initiation Time: 05/10/05 10:36:08 Run Code: 1115746568 This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 358 ft 2 Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 22.3% Number of Dwelling Units: 1.00 Total Conditioned Volume: 2,864 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 358 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Rnnf 515 0.024 0 a Wall 70 0 088 _�_ go ®LJ ® ❑ Rig Roof (.g 38 2x4 94) 1 ct Floor 1 9Y416) 1 st Floor Wall 179 0 088 a go Wall 100 0088 0 EN IN ❑ ❑ El R_1� 132416 1st Eloor R -1s Wall /tn/ 1s 2x416) 1ct Flnnr R-13Wall pN 132x41R� 1 s Floor _ _90 Wall 16 0.088 a g 0 ❑ ❑ ❑❑ n F-1 ❑❑ ❑❑ ❑❑ ❑❑ ❑❑ ❑❑❑ El Run Initiation Time: 05/10/05 10:36:08 Run Code: 1115746568 3.1 By EnergySoft User Number: 5672 0050 Page:5 of 7 Computer Method Summary (Part 2 of 3) C -2R Kett Phillips 5/10/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J— Window Front (North) 3n n 06M O.53 O _QQ Qoubte NonMtl Tinted) -fa uIt 1st Floor 2 Window Front (North) 50.0 0.600 0.53 0 90 Double NonMd Tinted Default 1st Floor 3 Window Front (North) 0.0 0.000 1.00 0 90 1st Floor INTERIOR AND EXTERIOR SHADING Window Overhand Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 6.0 6.0 0.1 6.0 6.0 0.1 2.0 0 0.1 2.0 0 2 Buq Screen 0.76 3 Bug Screen 0.76 EnergyPro 3.1 By EnergvSoft User Number: 5672 Job Number: 0050 Page:6 of 7 Computer Method Summary Duct R -Value (Part 3 of 3) C -2R Location / Comments Hydronic Piping Pipe Pipe Keri Phillips 5/10/2005 Project Title Diameter Thick. Date THERMAL MASS FOR HIGH MASS DESIGN Cooling Equipment Minimum Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Site in Mortar 515 Is — 24 -0-67- R -.-U9 Roof (R 38 2x_4_.2.4) 2 1 st Floor / Exterior Mass _name Wall Stucco 70 0_50 21 00.47 R-13 Wall (W.13.2x4.16) 2 1 st Floor / Exterior Mass Frame Wall Stucco 179 0.50 —21 O47 R-13 Wall QN.13.2x4.16) 2 1 st Floor / Exterior Mass Mme Wall Stucco 100 0_50 21 0_47 R-13 Wall (V11.13.2x4.16) 2 1st Floor / Exterior Mass _Frame Wall, Stucco _16 0.50 —21 0.47 R-13 Wall (W.132(4.16) _2 1 st Floor / Exterior Mass PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter T6 0.76 0.0 _ 0 1st Floor HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location pump, etc.) (AFUE/HSPFXducts/attic, etc.) Duct R -Value Thermostat Type Location / Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments WATER HEATING SYSTEMS Rated' Tank Energy Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 05/10/05 10:36:08 Run Code: 1115746568 Ener Pro 3.1 By Ener Soft User Number: 5672 Job Number: 0050 Pa e:7 of 7