Loading...
2016-2-8 - 5-YR SPK CERT - PASSTestitig, and MaintenAnte, CoveyInspect)", NFPA25 property Infosxtialion: -as amended. by CCR,T10e IS • wl ti: r Name: One Eleven La Quinta Center Occupancy/Use: M Address: 78700, 78710, & 78982 Hwy 111 Construction Type: Type II-B OF CA {� - �4r City. La Quinta 0 No. Stories: ZIP: 92253 Year Constructed: 2003 Luann ►�Ill�'` Contact: Telephone: (760) 771-3354 Contractat tnfaren�ytio�i; ` ;-'' _? �lturiiar of 5ysem FfiSers Name: Desert Fire Extinguisher Co., Inc Copy sent to: Address: 558 E Industrial Place E] Owner Date: City: Palm Springs ❑ Fire AHJ Date: State: CA ❑ Contractor Date: 02/08/16 Telephone: (760)322-0995 NOTES: 1) For specific inspection, testing, and maintenance C16-563921 requirements and information, see NFPA 25, 2011 CA License#: Edition as amended by California Code of Regulations, Title 19, §901 to §906. Job #: 5 year 2) Inspection items may be performed by the owner in Performed by: Paul Smith accordance with California Code of Regulations, Title 19, §904.1(a) Cbedik boKf6r'bkh System inspected and etiter the number. of forms. used .3iacl :poxes (i 3i-ar (&ss) #.n indiCate.atatµs af,irtspepted system 4t end Forms Includedwab this Reporte Chapter iJ Automatic Sprinkler System 5 3 for Inapvctien. - of i ns ctlon. ❑ Standpipe and Hose System 6 0 EL ❑ Private Water Supply System 7 0 ❑ Fire Pump 8 0 ❑ Water Storage Tank 9 0 ❑ ❑ Water Spray System 10 0 ❑ Foam Water Sprinkler System 11 0 1:1 EL ❑ Water Mist System 12 0 El 1:1 ❑ Concerns that are not deficiencies (i.e. Non-Sprinklered Areas) ❑ Yes ® No L.ataw urrnotpnumm..;Priq- QinmeniS NC110n ai:2ntl. OT.eaCh ►e$P..0CUVe for n.. AES 1 September 3, 2013 ,�v ss Rlser No, r Main Drain' Di.arneter Initial Static Residual Final Static P i' IVIA 1 Pressure Pressure Pressure Location Riser Diameter 1 Big 5- south east 4" 2" 80 75 80 P 2 AT&T- north west 3" 1 1/4" 90 80 90 P 3 Ross- South West 4" 2" 95 85 95 P This building has more than 5 risers. See additional AES 2.9 form attached Number of AES 2.9 forms attached: "�i•. ,.Sky �er��•����•.�,' }�� '�� � '�f,: ' . = Inspection T = Test M = Maintenance P = Pass F = Fail N/A = Not Applicable T Item Description NFPA 25 CA 0& Reference Date Comments Orgy .. P, F, NIA; 1.1 1 Control Valves — Identification Sign 133.1 02/08/16 P 1.2 1 Control Valves — Inspection 133.2 P 1,3 1 Waterflow Alarm Devices 5.2.5 P 1.4 I Supervisory Devices 5.2.5 P 1.5 1 Gauges (Wet Pipe Systems) 5.2.4.1 P 1.6 1 Hydraulic Design Information Sign (For hydraulically designed systems) 5 2 6 P 1.7 1 Enter Water Supply Pressure Below Riser Check 5.2.4.1 psi NA 1.8 1 Enter Water Supply Pressure Above Riser Check 5.2.4.1 psi P 1.9 1 Pressure Readings Acceptable 5.2,4.1 P 1.10 1 General Information Sign (not required for system prior to 2007 Edition NFPA 13) 5.2 8 NA 1.11 1 Heat Tape 5.2.7 NA 1.12 1 Spare Sprinklers 5.2.1.4 P 1.13 1 Fire Department Connections 13.7 P 1 14 1 Alarm Valves — Exterior Inspection 13.4.1 NA 1.15 1 Pressure Reducing Valves 13.5.1.1 NA 1.16 I Backflow Preventers 13.6.1 P Form AES 2.2 Sept. 3. 2013 = Inspection T = Test M = Maintenance P = Pass F = Fail N/A = Not Applicable item Dosc►lptinn NFPA 25 CA ed. Reference pate comments Only P,F,NIA 1.17 1 Small Hose Connections - Hose Valve` 5.1.6, 13.5.2 02/08/16 N/A 13.5.5.1 1.18 I JPRV — Fire Sprinkler Systems 13.5.1.1 N/A 1.19 1 Buildings (Freeze Protection) 4.1.1.1 Owner's Responsibility N/A 1,20 1 Sprinklers 5 2 1 P 1 21 1 Sprinklers - Accessible Concealed Space 5.2.1.1.6 p 1.22 1 Pipe and Fittings 5.2.2 P 1.23 1 Pipe and Fittings - Accessible Concealed Space 5.2.2.3 p 1.24 1 Hangers 5.2,3 P 1.25 1 Hangers - Accessible Concealed Space 5.2.3.3 P 1.26 1 Seismic Braces 5.2.3 P 1.27 1 Seismic Braces - Accessible Concealed Space 5.2-3 3 P 1.28 1 Unsprinklered Areas CFC 901.4 []Yes ® No 2 1 T Field Service Test Required 5.3.1 If REQUIRED, Enter'F' until Send Report to Fire Code Official results are returned from Lab 2.2 T Recalled Sprinklers Title 19 If not present = Pass; If present = Fail 904.1(c) P 2.3 T Water Flow Alarm Devices 5.3.3 90 secs max. Enter time 13.2.6 45 sec. P 2.4 T Main Drain Test 13.2.5 (Enter data on Page 9 of this form) 13.3.3.4 P 2.5 T Control Valve - Position 13.3.3.2 P 2.6 T Control Valve — Operation 13 3.3.1 p 2.7 T Supervisory Devices 13.3.3.5 p 2.8 T Backflow Preventer Assemblies 13.6.2 N/A 2.9 T Small Hose Connections" 13.5.2.3 w/PRV Hose Valves — Partial Flow Test 13.5.3.3 NIA 2.10 T PRV — Fire Sprinkler Systems 13.5.1.3 N/A 2.11 T Pressure Gauges - Calibration 5.3.2 P 2.12 T Small Hose Connections* 13.5.6.2.2 N/A ' Small hose connections are hose valves and optional hose supplied by the fire sprinkler system. They do not include Class I, II, or III standpipe systems. Form AES 2.2 Sept. 3, 2013 Property Information ' CAS Contractor or Licensed Owner Information a uilding Name One Eleven La Quinta Center r Name Desert Fire Extinguisher CO., INC ddress 78700, 7810 & 78982 Hwy 111 iah # ity La Quinta - :,': Ct"' � r•.... .:,�.,y �' -,y::•:_ „�'- r a• •'v?- x.:y � r. I; :�.-� Y:.:�; .-� • - - 4Y ram. :rig` '"-3'r 'f i.c :cam="`-.?' :�: =Inspection+ T = Test M =Maintenance P = Pass F = Fail N/A = Not Applicable Item Description P NFPA 25 CA ed. Reference Bate Comments Only i ,t',fFiA 3.1 M Check Valves - Internal inspection 13.4.2 02/08/16 P 3.2 M Control Valves 13.3.4 P 3.3 M FDC - Backflush 14.3.2.3 14.3.2.4 P 3.4 M Internal Pipe Inspection - See Deficiencies and Comments Section for Results. 14.2 ,/ Yes P No 3.5 M Obstruclion Investigation Required. If "Yes", see Deficiencies and Comments Section for Results 14'3 P 3.6 M System Returned to Service 4.5.3 Yes 1 No P i hereby certify that the fire protection equipment listed above has been Ailly inspected, tested, and maintained on this date by the company indicated above, in accordance with CCR, Title 19, Sections 901 to 906 and that the equipment is fully operable except as noted in the "Deficiencies and Comments" section of this form. Print Name Paul Smith Signature Paul Smith Date 2016082509s6320700' Date 02/08/16 Form AES 2.2 Sept. 3, 2013