Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations Page 1 of 5
Project Name: DZIADYK RESIDENCE ClimateZo5 # 1 of stories
General Information
Site Address:80-395 CAMARI LLO WAY
Enforcement Agency:
Date:
Building Type Single Family [] Multi Family
Circle the Front Orientation: N; E, , W, or degrees
Conditioned Floor Area (CFA): 2,811
Project Type: x Alterations Envelope[] Fenestration Roof HVAC
Replacement or Change Out Duct Replacement 0 Water Heater
NOTE: Thu form is not to be used for Newly Constructed Buildings or Additions
Insulation Values For Opaque Surfaces (for Furring use the Mass and Furring Strips Construction table below)
Assembly Alteration
Im Opening of framed cavity alone—Alterations that involve the opening of the framed cavity ofa wall, ceiling, or floor must install the
mandatory minimum insulation value per §150 for the altered assembly. Fill in Columns A —C and enter mandatory insulation value in Column H.
Replacement of entire assembly— Replacement of an entire wall, ceiling, or floor assembly requires the installation of Component
Package- D insulation values in Table 151-C. Fill in Columns A — J.
Opaque Surface Details For the furred portioned of Mass Walls see Furring Strips Construction Table below.
A B I C D
E
F G I H I I J
Proposed ee ore
Standard
Values From JA4
Table
Framing Thickness,
in Furring Space from Reference
Framed Continuous
JA4
Proposed
Tag/ Assembly Name
ID' or Type 2
Material Spacing,
and Size or Other'
U-
factor4
JA4 Table Cavity Insulation
Numbers R-value6 R -Value
Assembly
Row/Cols
Assembly
U -factor'
WALL
2x6
U
U �
Q G
d >
!O
AssemblyA
U
E- o 0
9
>
Final
Mass
Name or JA4 Table
Note: For furred assemblies, accounting for Continuous Insulation R -value, see Page JA4-3 and Equation 4-1. For calculating furred walls use the Mass and
Furring Construction table below.
1. For Tag/ID indicate the identification name that matches the building plans.
2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc ... Indicate in column G the Frame
material and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies.
3. Enter the thickness for mass in inches or Spacing between framing members enter; 16 "or 24 "OC; or Other for all other assembly description
such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel and etc....
4. Based on the Climate Zone; enter the equivalent U factor found in JA4 Table based on the R -Value from Table 151-B, C, or D
5. Enter the Table number that closely resembles the proposed assembly.
6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise, enter "0".
7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter "0 ".
8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J
9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply.
Furring Strips Construction Table for Mass Walls Onl
A I B I C I D I E
F I G I H I J I K
L
M
Proposed Properties of Masonry and Concrete
Added Interior or Exterior Insulation
Walls From Reference
in Furring Space from Reference
Joint A ppendix Table 4.3.5 4.3.6 4.3.7
Joint Appendix Table 4.3.13
$
U
U �
Q G
d >
!O
AssemblyA
U
E- o 0
9
>
Final
Mass
Name or JA4 Table
,no, g N
E
E c t
Assembly
Thickness
Type Number'
¢ >
.5 a
Q >
U-factor6'�
Comment
N/A
-Registration Number: Registration Date/Time: HERS Provider:
2008 Residential Compliance Forms
March 2010
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations Page 2 of 5
Project Name: DZ IA DY K RESIDENCE Climate Zone #151 # of Stories
Mass and Furring Strips Construction(footnotes)
1. Indicate the type of assembly to include; Hollow Unit Masonry Walls, Solid Unit Masonry, Solid Concrete Walls, Etc. Additional assemblies can
be found Reference Joint Appendix JA4.
2. This is the U -Factor based on the thickness of the assembly in inches.
3. The R -value of the insulation to be added on the interior or exterior of the assembly.
4. The Calculated R- Value is the R -value of the furred out section of the assembly.
-6. The Final Assembly is calculated using Equation 4-2 or Equation 4-4of the Reference Joint Appendix JA 4. The equation is the inverse of Column
added to Column I. Column K is the inverse from column J.
7. Insert the calculated U- actor value on to the Opaque Sur ace Details in Column J
FENESTRATION PROPOSED AREAS
Replacing window alone — Replacement windows shall meet the U -Factor and SHGC Value requirements of Component Package D in
Table 151-C. The Total Fenestration and West facing Area requirements are not applicable.
Q Adding 50ft2 or less of window area — Newly installed windows shall meet the U -Factor and SHGC Value requirements of Component
Package D in Table 151-C.
0 Adding more than 50ft2 of window area — Newly installed windows shall meet the U -Factor and SHGC Value and the Fenestration
Area requirements of Component Package D in Table 151-C. Complete the Altered Fenestration Allowed Area Table on Page 2 of the CF -IR -AL T
Orientation
D
Fenestration Type and Frame (North, East, PropsedAreal Maximum Maximum
(Window, Glass Door or Skylight) South, West) (ft U -factor , 3 SHGC2' 1,4
NFRC or Default
Values
17'x10' SLIDING GLASS DOOR SOUTH 170 .40 .33
G
CFA of
Allowed
Existing
Allowed
1. Fenestration area is the area of total glazed product (i.e. glass plus frame). Exception: When a door is less than 50% glass, the fenestration
area may be the glass area plus a "2 inch frame" around the glass.
2. Enter value from Component Package D Requirements in Table 151-C.
3. Actual fenestration products installed and as indicated in CF -6R -ENV Form shall be equivalent to or have a lower U factor and/or a lower
SHGC value than that specified on the CF -IR ALT Form.
4. Submit a completed WS -3R Form if a reduced SHGC is calculated with exterior shading.
5.1f applicable at this stage enter "NFRC" or NFRC Certified windows or are CEC "Default " valuesfound in Table 116-A or B.
ALTERED FENESTRATION
ALLOWED AREAS
(Complete if more than 50ftr
of fenestration is added)
A
B
C
D
E
F
G
CFA of
Allowed
Existing
Allowed
Entire
% of
Fenestration
Area
Fenestration
Area
Proposed Area' 4
Dwelling
CFA','
Area4
Removed
Area Added
A x B)
(E -D) + C
Total Fenestration
N/A
>
Area"(ft') ft
West Fenestration Area
(Required In
>
CZ's 2,4&7-15
1. The Proposed West Fenestration Area includes West -sloping skylight area and any other skylight area with a pitch less than 1:12.
2. Enter 20% when no West orientation restriction or 15% when West fenestration is being installed in Climate Zones 2, 4, & 7-15. Note that the
maximum allowed fenestration can only be 5% of the CFA as indicated in Column F. Column G must be equal to or less than Column F.
3. In climate zones 2, 4, 7-15, no more than 5% of the CFA is allowed for west facing glazing.
4. Existing Fenestration area must be counted toward the maximum allowed 15% or 20% of the whole building and caiculated in Column G. The
Proposed Area must be less than or equal to Column F.
5. Enter the fenestration removed as part of the alteration if any in column D.
6. Enter the Fenestration area that is being added as part of the alteration.
Registration Number_ __- - -_ _ Registration Date/Tim_ e_, HERSProvuler:
2008 Residential Compliance Forms March 2010
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations Page 3 of 5
DZIect Name: ADYK RESIDENCE 151tmate Zone # 1 of Stories
ROOFING PRODUCTS (COOL ROOFS) §151(1)12
When the area of exterior roofsurface to be replaced exceeds more than 50% of the existing roof area, or more than 1,000.f?, whichever is
less, the new roofing area must meet the roofing product "Cool Roof" requirements of §152(b)l i, 152(b)IHii, or 152(b)1Hi L
Check applicable alternative or exception below if the roof alteration is exempt from the roofing product "Cool Roof' requirements. Note: If any
one of the alternatives or exception below is checked, the Aged Solar Reflectance and Thermal Emittance requirements for roofing products in
§118(1) are not applicable. Do not fill table below.
EJ Cool Roofs Not Required in Climate Zones 1-12, 14, and 16 with a Low Sloped. Less or 2:12 pitch.
Cool Roofs Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped Roofs (pitch greater than 2:12) and product unit weight less
than 5lb/ft
Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch > 2:12)
E] Insulation with a thermal resistance of at least 0.85 heft •°FBtu or at least a 3/4 inch air -space is added to the roof deck
over an attic; or
Existing ducts in the attic are insulated and sealed according to § 151(f)10; or
In climate zones 10, 12 and 13, with 1 ft of free ventilation area of attic ventilation for every 150 f12 of attic floor area, and
where at least 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge; or
Building has at least R-30 ceiling insulation; or
Building has radiant barrier in the attic meeting the requirements of § 151(f)2; or
Building has no ducts in the attic; or
In climate zones 10, 11, 13 and 14, R-3 or greater roof deck insulation above vented attic.
Exception to §152(b)1Hiii, Low -slope roof (pitch <_ 2:12)
Building has no ducts in the attic.
Other Exceptions
Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the below Cool Roof criteria.
_ Roof constructions that have thermal mass over the roof membrane with at least 25 lb/ft2 is exempt from the below Cool Roof criteria.
Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise,
Check the applicable box below if Exem t from the Roofing Products "Cool Roof' Re uirement:
Roof Slope
Product Weight
Product
Aged
Solar
Thermal
CRRC Product ID Number'
< 2:12 > 2:12
< 5lb/ft2 > 5lb/ft2
Type 2
Reflectance''4
Emittance
SRIS
N/A
0 1
n
0
0
1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at tivww.coolroofs.org/products/search.
2. Indicate the type of product is being used for the rooftop, i.e. single ply roof, asphalt roof, metal roof, etc.
1. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same
directory and use the equation (0.2+01(pi„igia1— 0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance.
4. Check box if the Aged Reflectance is a calculated value using the equation above.
5. Calculate the SRI value by using the SRI- Worksheet at http:lAviviv.energv.ca.vov/title24/and enter the resulting value in the SRI Column above and attach acopy of
the SRI- Worksheet to the CF -JR.
o apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
ecommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)4. Select the applicable coating:
:1 Aluminum -Pigmented Asphalt Roof Coating
0 Cement -Based Roof Coating
� Other
Registration Numbers Registration Date/Time: HERS Provider:
2008 Residential Compliance Forms March 2010
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations Page 4 of 5
Project Name -, RESIDENCE Climate Zone#1 C 1 of Stories
HVAC SYSTEMS - HEATING
List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. Individual dwelling DHW heaters must be
gas or propane fired. Hot water pipe insulation from the DHW heater to the kitchen (s) and on all underground hot water pipes is required in all
Minimum
Duct or Piping
Configuration
Heating Equipment
Efficiency
Distribution Insulation
Thermostat
(Central, Split,
Type and Capacity', 2,3
AFUE or HSPF
Type and Location R -Value
Type
Space, Package or H dronic
EXISTING
System
Capacity (gal)
Thermal Efficiency
R-Value3
EXISTING
1. Indicate Heating Type (Central Furnace, Wall Furnace, Heat pump, Boiler, Electric Resistance, etc.)
2. Electric resistance heating is allowed only in Component Package C, or except where electric heating is supplemental (i.e., if total capacity
< 2 KW or 7,000 Btu/hr electric heating is controlled by a time -limiting device not exceeding 30 minutes). See §151(b)3 exception.
3. Refer to the HERS Verification section on Page 4 of the CF -IR -ALT Form for additional requirements and check applicable boxes.
4. Indicate Type or Location (Ducts, Hydronic in Floor, Radiators, etc.)
HVAC SYSTEMS - COOLING
Minimum
2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do
not allow the installation of a recirculating water heating system for single dwelling units.
3. The external water heating tank and i es shall be insulated to meet the requirements o 150 ' .
Efficiency
Duct or Piping
Configuration
Cooling Equipment
(SEER/EER or
Distribution
Insulation
Thermostat
(Central, Split,
Type and Capacity', 2
COP)
Type and Location
R -Value
Type
Space, Package or H dronic
EXISTING
1. Indicate Cooling Type (A/C, Heat pump, Evap. Cooling, etc)
2. Refer to the HERS Verification section on Page 4 of the CF-/R-ALTForm for additional requirements and check applicable boxes.
3. Indicate Type or Location Ducts, H dronic in Floor, Radiators, etc.
WATER HEATING
List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. Individual dwelling DHW heaters must be
gas or propane fired. Hot water pipe insulation from the DHW heater to the kitchen (s) and on all underground hot water pipes is required in all
component packages in all climate zones.
External Tank
Water Heater Type/Fuel
Distribution Type
Number In
Tank
Energy Factor or
Insulation
Type'
(Standard, Recirculating)2
System
Capacity (gal)
Thermal Efficiency
R-Value3
EXISTING
1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc.)
2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do
not allow the installation of a recirculating water heating system for single dwelling units.
3. The external water heating tank and i es shall be insulated to meet the requirements o 150 ' .
SPECIAL FEATURES The enforcement agency should pay special attention to the Special Features specified in this checklist below.
These items may require written 'usti kation and documentation and special verification.
NEW ROOF ASSEMBLY - Radiant Barrier
The radiant barrier requirement of § 151 2 does not apply to roof alterations.
Slab Edge (Perimeter) Insulation YES JxJNO
YES: In Climate Zone 16 in Component Packages D, R-7 insulation is required.
Heated Slab Insulation [:] YES ENO
YES: Slab edge insulation required for all heated slabs in all Climate Zones. See details in Table 118-A of the standards.
Raised Slab Insulation - YES ®x NO
YES: In Climate Zones 1, 2, 11, 13, 14 & 16, R-8 insulation is required; in Climate Zones 12 & 15, R-4 is required under component Package D.
Thermal Mass
To obtain Compliance Credit for the installation of thermal mass, use the Performance Approach.
2008 Residential Compliance Forms March 2010
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations Page 5 of 5
Project Name:DZIADYK RESIDENCE Climate Zone #1 5 1 of Stories
HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this
checklist below. A completed and signed CF -4R Form for all the measures specified shall be submitted to the building inspector before final
inspection.
Duct Sealing & Testing HERS verification is required for this measure.
El YES NO YES: In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned
space, the ducts are to be sealed per §152(b)1Dii and the newly installed ducts are to be insulated per §151(f)10.
EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos.
OYES ONO YES: In Climate Zones 2 and 9-16, if the existing space -conditioning system (HVAC equipment and ducting) is replaced, the
ducts are to be sealed per § 152(b)1 Di.
OYES ONO YES: In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including the replacement of the air handler,
outdoor condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) the ducts are to be
sealed per §152(b)IE.
EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS
verification in accordance with procedures in the Reference Residential Appendix RA3.
EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space.
EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos.
Refrigerant Charge - Split System HERS verification is required for this measure.
YES 0 NO YES: In Climate Zones 2 and 8-15, when the existing HVAC equipment is replaced (including the replacement of the air
handler, outdoor condensing unit of a split system A/C or heat pump, cooling or heating coil, or the furnace heat
exchanger) a refrigerant charge measurement shall be verified per 152(b)1F.
Central Fan Integrated (CFI) Ventilation System and Fan Watt Draw
The ventilation requirements of §150(o) do not apply to existing residential homes.
Ducted Split Systems - Air Conditioners and Heat Pumps: Airflow HERS verification is required for is measure.
0 YES 0 NO YES: In Climate Zones 10 through 15, when the existing space -conditioning system (HVAC el 'pment and ducting) is
replaced, the airflow and fan watt draw shall be verified per 152 lCi to meet the re rements of 151(f)7B.
F/A
Documentation Author's Declaration Statement
• I certify that this Certificate of Compliance documentation is accurate and complete. /11
Name: STEPHEN R. NIETO
Signature:
Company: SOUTH WEST CONCEPTS
te.06/19/2011
Address: CALLE ESTADO, STE 105
If Applicable 'CEA or CEPE
(Certification #):
City/State/Zip: A QUINTA, CA 92253
Phone: 760-564-4707
Responsible Building Designer's Declaration Statement
• I am eligible under Division 3 of the California Business and Professions Code to accept responsibility r the building design identified on
this Certificate of Compliance.
• I certify that the energy features and performance specifications for the building design identified on Certificate of Compliance conform
to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations.
• The building design features identified on this Certificate of Compliance are consistent with the in ation provided to document this
building design on the other applicable compliance forms, worksheets, calculations, plans a ations submitted to the enforcement
agency for approval with this building permit application.
Name: STEPHEN R. NIETO
signature:
Company: SOUTH WEST CONCEPTS
Date:06/19/2011
Address: 78-115 CALLE ESTADO, STE 105
License:
rity/State/Zip:LA QUINTA, CA 92253
Phone: 760-564-4707
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at. 1-800-772-3300.
Registration Number: Registration Date/Time: HERS Provider:
2008 Residential Compliance Forms
March 2010