13-1148 (RER) Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Meyer's Guest House Addition
46370 Cameo Palms Dr.
La Quinta, CA 92253
Project Designer:
AA Design
81-692 Rancho Santana Dr.
La Quinta, CA 92253
760-272-4285
Report Prepared by:
Gina Rose -Starkey
EQS, Inc.
P.O. Box 170
Gold Hill, OR 97525
760-218-3350
Job Number:
Date:
10/29/201
The EnergyPro computer program has been used to perform the calculations summ
authorized by the California Energy Commission for use with both the Residential
This program developed by EnergySoft, LLC
5.1 by EnergySoft User Number.
I—P, ()UaNTA
& sAFEV DEPT.
��O ��N
FdR C�Ngi
zed in this c li repop his p cet
id Nonresi i I BuiPi
DPSE
and is I
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
Eiv ®
gUkt°jr4G &
VIOVED
oR CpNSTR
gY
QATE ��
EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 5862
1
2
3
9
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Meyer's Guest House Addition
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existin + Additio Alteration 11012912013
Date
Project Address
46370 Cameo Palms Dr. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Tota ond.FloorAreaY
1,444
Addition
0
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be pr ed per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Wall Wood Framed R-19 1,701 Existing
Door Opaque Door None 40 New
Slab Unheated Slab -on -Grade None 1,444 Perim = 246' Existing
Roof Wood Framed Attic R-30 1,453 Existing
Wall Wood Framed R-21 308 New
Door Opaque Door lnsul 20 Existing
Roof Wood Framed Attic R-38 135 New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Left (N) 308.3 0.400
0.26 none none Bug Screen New
Right (S) 96.0 0.400
0.26 none none Bug Screen New
HVAC SYSTEMS
Qtv. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE
Split Air Conditioner 14.0 SEER Setback
New
HVAC DISTRIBUTION
Location HeatingCoolingDuct
Du
Location �- -Vall T
t tus
HVAC System Ducted
Ducted Attic, Ceiling"I uen(01 Ot- "r~8-9,; Ne
••
i rrM
WATER HEATING
Qty. Type Gallons Min. Eff Distribution St�tG
1 Instant Gas 1
0.95 Point ofxUse
ew
�j 0,
EnergyPro 5.1 by EnergySoft User Number: 5862
RunCode: 2013-10-29T16:57:0 ID:
Page 3 of 11
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Meyer's Guest House Addition
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ® Existing+ Addition/Alteration
Date
11012912013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 956.0 ft -Exposed Slab Floor, 3.500" thick at Zone 1
HIGH MASS Design - Verify Thermal Mass: 488.0 ft2 Covered Slab Floor, 3.500" thick at Zone 1
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The HVAC System HVAC System incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specified criteria.
asnnkril
Cj+;D
�4(*FE�
f O DONS r�
gY
ppCE
EnemyPro 5.1 by EnerqySoft User Number., 5862 RunCode: 2013-10-29T16:57:0 ID: Page 4 of 11
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Meyer's Guest House Addition
❑ Multi Family 10 Existing+ Addition/Alteration
10/29/201
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kgtu/ft2- r
Space Heating 10.08 8.00 2.08
Space Cooling 88.21 96.32 -8.11
Fans 17.68 21.87 -4.19
Domestic Hot Water 19.85 9.22 10.64
Pumps 0.00 0.00 0.00
Totals 135.82 135.40 0.42
Percent Better Than Standard: 0.3%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (tM 100 0
Fuel Available at Site: Natural Gas (N) 1,123 308
Raised* Floor Area: 0 (E) 910 0
Slab on Grade Area: 1,444 (S) 340 96
Average Ceiling Height: 9.0 Roof 1,588 0
Fenestration Average U -Factor: 0.40 TOTAL: 404
Average SHGC: 0.26 Fenestration/CFA Ratio: 28.0%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation. is accurate and complete.
Documentation Author
..
Company EQS, Inc.G`(—
10/29/2013
Address P.O. Box 170 Name Gina Rose -Starkey
City/State/ZipCity/State/Zip Gold Hill, OR 97525 Phone 760-218-3350 Signed N D e
The individual with overall design responsibility hereby certifies that the propose_d.buildln�d s'ig 1re°p er'd this set
wits iiica lbn and
of construction documents is consistent with the other compliance for s-atidw
ork9ROets, Ye-�p ,
with any other calculations submitted with this permit application, and recognizes t�iatcorttplra c� us'Nact de ign,
duct sealing, verification of refrigerant charge, insulation installation qualit�rand buil8ing n q"P,e s�irequir
installer testing and certification and field verification by an approved HERS rate ro, V?'00-
`
N
Designer or Owner (per Business & Professions Code) �4R
Company AA Design �(
Rancho Santana Dr.
Address 81-692 Name
City/State/Zip La Quinta, CA 92253 Phone 760-272-4285 Signed License # Date
EnerqvPro 5.1 by EnemySoft User Number- 5862 RunCode: 2013-10-29T16:57.0 /D: Pa e 5 of 11
CERTIFICATE OF COMPLIANCE: Residential
FENESTRATION SURFACE DETAILS
(Part 4 of 5)
CF -1 R
Project Name
Meyer's Guest House Addition
Building Type m Single Family
❑ Multi Family
❑ Addition Alone
M Existing+ Addition/Alteration
Date
11012912013
OPAQUE SURFACE DETAILS
Window 48.3
0.710 Default '
0.73 Default
0 Removed
Double Metal Clear
Surface
Type
Area
U- Insulation
Factor Cavit Exterior Frame Interior Frame Azm I Tilt Status
Joint Appendix
4
Location/Comments
Wall
224
0.074 R-19
01
90 Existing
4.3.1-A5
Zone 1
0.400 NFRC
Door
38
0.700 None
0
90 Removec 4.5.1-A2
Zone 1
Window 34.0
Wall
810
a074 R-19
90
90.Existing
4.3.1-A5
Zone 1
Window 34.0
Wall
70
0.074.R-19
180
90 Existin
4.3.1-A5
Zone 1
Window 40.0
Door
40
0.700 1 None
180
90 Removec 4.5.1-A2
Zone 1
8
Door
20
0.500 None
180
90 New
4.5.1-A4
Zone 1
9
Wall
437
0.074 R-19
0
90 Existing
4.3.1-A5
Zone 1
10
Door
40
0.700 None
0
90 Removec 4.5.1-A2
Zone 1
Slab
956
0.730 None
0
180 Existing
4.4.7-A1
Zone 1
Slab
488
0.730 None
0
180 Existing
4.4.7-A 1
Zone 1
Roof
1,453
0.031.R-30
0
0 Existing
4.2.1-A20
Zone 1
Wall
154
0.069 R-21
0
90 New
4.3.1-A6
Zone 1
Wall
80
0.074 R-19
90
90 Existing
4.3.1-A5
Zone 1
Door
20
0.500 None
90
90 New
4.5.1-A4
Zone 1
Wall
154
0.069 R-21
180
90 1 New
14.3.1-A6
Zone 1
Wall
RO 1
0.074 R-19
270
90 1 Existino
14.3.1-A5
Zone 1
Ove hang
Len Ftclt LExt
PER I
FENESTRATION SURFACE DETAILS
A3.01
ID I Type Area I U -Factor SHGC Azm I Status Glazing Type Location/Comments
1
lWindow 37.51
0.400 NFRC 1
0.26 NFRC
1 0 New I
Per Contractor
Zone 1
2
Window 48.3
0.710 Default '
0.73 Default
0 Removed
Double Metal Clear
Zone 1
3
Window 3.8
0.400 NFRC
0.26 NFRC
0 New
Per Contractor
Zone 1
4
Window 29.0
0.400 NFRC
0.26 NFRC
0 New
Per Contractor
Zone 1
5
Window 34.0
0.400 NFRC
0.26 NFRC
0 New
Per Contractor
Zone 1
6
Window 34.0
0.400 NFRC
0.26 NFRC
0 New
Per Contractor
Zone 1
7
Window 40.0
0.400 NFRC
0.26 NFRC
0 New
Per Contractor
Zone 1
8
Window 34.0
0.400 NFRC
0.26 NFRC
0 New
Per Contractor
Zone 1
9
Window 96.0
0.400 NFRC
0.26 NFRC
0 New
Per Contractor
Zone 1
10
Window 96.0
0.400 NFRC
0.26 NFRC
180 New
Per Contractor
Zone 1
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang
Len Ftclt LExt
Left Fin
RExt Dist Len
H t Dist
Right Fin
Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
v r
VO
9
Bu Screen
0.76
10
Bug Screen
0.76
-
r_
M nAT
Ener Pro 5.1 by Ener Soft
User Number: 5862
RunCode: 2013-10-29T16:57:0 ID:
Page 6 of 11
CE-R-TIFICATE OF • •-
of
Project Name
Meyer's House Addition
Building Type 0 Single Family
1:1 Multi Family
0 Addition Alone
r. .Addition/Alteration
OPAQUE
Joint Appendix
4 Location/Comments
FENEST ATION SURFACE DETAILS
0fi9`S�
�� ... .
.Standards=Labeled Value
._Standards:
.- SHADING DETAILS
Exterior Shade Type
IV
M
w-F—Ewd
121ml MIN NJ an mm
�r�:�EW�Mmk�
Ener-qyPro
Page 7 .
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Meyer's Guest House Addition
Building Type
® Single Family ❑ Addition Alone
❑ Multi Family 91 Existing+ Addition/Alteration
Date
10/29/201
BUILDING ZONE INFORMATION
System Name Zone Name New
Floor Area
Existinq Altered Removed Volume Year Built
HVAC System Zone 1
1,444 12,996 1995
Totals
01 01 1,4441 0
HVAC SYSTEMS
System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System 1 Central Furnace 78% AFUE Split Air Conditioner 14.0 SEER Setback New
HVAC DISTRIBUTION
System Name Heatin' Cooling
Duct Ducts
Duct Location R -Value Tested? Status
HVAC System Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Ext.
Standby Tank
Loss or Insul. R-
Pilot Value Status
State GAX190
1
Instant Gas
Point of Use
180,000
1
0.95
n/a n/a New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATINGsSYSTElJlI JN 5
w
Hot Water Piping Length
¢
LIPDff �j 5& ipedN InsuControl
S stem Name`°.: Len`tfiFr Thic
Qt . HP
Plenum Outside
Buried
❑
❑
❑
❑
pri�i
❑
❑
Ene Pro 5.1 by EnerqySoft User Number: 5862 RunCode: 2013-10-29T16:57:0 ID: Pa e 8 of 11
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Meyer's Guest House Addition
Date
11012912013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
.Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
e ui ed with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect ho er
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on AV the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating s ste and'�n ' e* nathv�
recirculatingsections of hot water pipes are insulated per Standards Table 150-B. ��
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping ins lateT,etw6en a rce d ne irect hot
water tank shall be insulated to Table 150-B and Equation 150-A. \
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 p415,e'e the, reui�es` nt t ards Tab e
123-A. 6
150 • 3A: Insulation is protected from damage, including that due to sunlight, moisture, a ui n-er aintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclose y i
conditioned space.
§1500K Solar water -heating systems and/or collectors are certified by the Solar Rating a'dC rt Pica ' or oration.
EnergyPro5.1 by EnergySof7 User Number- 5862 RunCode: 2013-10-29T16:57:08 1D: Page 9 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name
Date
Meyer's Guest House Addition
11012912013
§150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal o enin s greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and $ a Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line-
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw-base socket.
150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
be-V* etc
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitc i n pige'
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 fizor 100 watts f r d 'e ling itr'ia� gy%m be
exempt from the 50%high efficacy requirement when: all low efficacy luminaires int isle aecontrofa�aanu l on occu nt
dimmer, tl installe
sensor, energy management system (EMCS), or a multi-scene programmable cbnt7o sys�emapra'd'�fl er�r� �ara
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility r�bom'sLa?b-ft�g e ick Dori �.' a
V� °1`
manual-on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more th' n 20 W�'S?O� O Oer linear foot of
illuminated cabinet.
gY
EnergyPro 5.1 by EnergySoft User Number: 5862 RunCode: 2013-10-29T16:57:08 ID: Page 10 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Meyer's Guest House Addition
11012912013
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the Iumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
-y ®V7- LA QU1NTA
C11
SAF�'�EPT-
BUILDIN
PFIO\]F-D
FOR ONSTRUCTION
DATE
EnergyPro 5.1 by EnergySoft User Number. 5862 RunCode: 2013-10-29716:57:08 ID: Page 11 of 11