Loading...
Darby Estates TR 31087 (Plans 1 & 2) 2013 Codes - Title 244 I Title 24 Energy Report 9 at D.'arb La Quinta Climate Zone #15 RF-CEIVED NOV 0 6 2014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT 12013 Build in Energy' ner Efficiency Standards BEG Project No.: 13174U GHA Companies Len Nobel Company Heritage Energy Group, LLC November 4, 2014 Tel: (949) 789-7221 / Fax: (949) 789-7222 4 �r CITY OF LA QUINTA BUILDING &SAFETY cEPT. APPROVED "FOR CONSTRUCTION DATIR 119 14 By . CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24. Analysis Input File Name: 13174UP1.xml iy CF1 R-PRF-01 Page 1 of 9 .GENERAL INFORMATION 01 Project Name Plan 1 02 Calculation Description Title 24 Analysis 03 Project Location Darby Lane 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2359 15 Number of Zones 1 16 Slab Area (FT2) 2359 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) N/A 21 Glazing Percentage ("/o) 16.30% COMPLIANCE RESULTS `' sk �•-+ `" 2,Ya €' Yr:,: 01 Building Complies with Computer PeIrfo mance 02 This building incorporates,features that �egwre;f'eld testing-anWor`venfication by a`certified HERS'ratTenunde Ft�he�supen!ision of a CEC-approved HERS provider. 03 This building incorporates one or more SpecialFeatures shownbelow Registration Number: 214-N0132967A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-11-04 22:02:48 Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-04 20:13:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml kw CF1 R-PRF-01 Page 2 of 9 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.41 2.58 -1.17 -83.0% Space Cooling 101.63 100.58 1.05 1.0% IAQ Ventilation 1.16 1.16 0.00 0.0% Water Heating 11.25 10.20 1.05 9.3% PV Credit ---- 0.00 0.00 -- North Facing Compliance Total 115.45 114.52 0.93 0.8% Space Heating 1.41 2.66 -1.25 -88.7% Space Cooling 101.63 99.60 2.03 2.0% IAQ Ventilation 1.16 1.16 0.00 0.0% Water Heating 11.25 10.20 1.05 9.3% PV Credit --- 0.00 0.00 ---- East Facing Compliance Total 115.45 113.62 1.83 1.6% Space Heating '^ 1.4:1, 3 12 Space Cooling t s' 101: 3 4, 1 0:52'^ -1.71 -121.3% IAQ Ventilation 1 16 a r y16, Q °� Water Heating1.125 r 10 20 { j. ff� 0.00 0.0% �, ;� PV Credit�' _ r y 0.00 1.05 0.00 9.3% South Facing Compliance Total' 115.45 115.00 0.45 0.4% Space Heating ` 1.41 2.75 -1.34 -95.0% Space Cooling v 101.63 96.38 5.25 5.2% IAQ Ventilation 1.16 1.16 0.00 0.0% Water Heating 11.25 10.20 1.05 9.3% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 115.45 110.49 4.96 4.3% Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-04 20:13:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD - Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml a: s CFIR-PRF-01 ' Page 3 of 9 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. ' • Window overhangs and/or fins - HERS FEATURE SUMMARY - W The following is a summary of the features that must be field -verified by -a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • Building Envelope Air Leakage • IAQ mechanical ventilation ` Cooling System Verifications: •, s ,; ;Verified EER _ e Verified SEER • Refrigerant Charge t �+ • Fan Efficacy Watts/CFM . HVAC Distribution System Verifications: t r • Duct Sealing Domestic Hot Water System Verifications. ;- .--None-. `. . .. , �,,.tin..e�C,acr.. _ ��l,.i/..�:a .`�....��,� :�r:��,..�b�ss...:y-fan s�,bs�.K.,. r:-f�:w. r-•r: ENERGY DESIGN RATING=y .-17 $1%rlxpf ;°� j This is the sum of the annual TDV energyensumption forreenergy use componentsmcl�uded in the performance c*m pliance;app oachtfor the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by,Title 24, Part-6-(such-as domestic appliances and consumerelectromcs) and accounting for the annual TDV energy offset by an on -site renewable energy system. J ' `zr_ = ' ' "§ ` . r'` w,. �} ,T, , ^•.• ° ".:` i Reference Energy Use Margin Percent Improvement Total Energy (kTDV/f2)" 'Sa ; 160.42. j`.yt r fi' N 's159 97,_7. 0.45 0.3% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms . Number of Zones , Number of Ventilation Cooling Systems Number of Water Heating Systems - Plan 1 2359 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 -06 07 ` Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling. Height Water Heating System 1 Water Heating System 2 Plan 1 2` Conditioned Res HVAC1 2359 r 10. DHW Sys 1 Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651' Report Generated at: 2014-11-04 20:13:22 f CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml CF1 R-PRF-01 Page 4 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft) Tilt(deg) Back Wall Plan 1 2 R-13 Wall 180 Back 305 78 90 Back Wall 2x6 Plan 1 2 R-19 Wall 180 Back 195 96 90 Right Wall Plan 1 2 R-13 Wall 270 Right 520 91 90 Right Wall 2 Plan 1 2 R-19 Wall 270 Right 100 0 90 Front Wall Plan 1 2 R-13 Wall 0 Front 90 20 90 Left Wall Plan 1 2 R-13 Wall 90 Left 688 100 90 Front Wall -Garage Plan 1 2 Garage R-13 Wall 0 Front 412 0 90 Right Wall Garage Plan 1 2 Garage R-13 Wall 270 Right 69 0 90 Left Wall 2 Plan 1 2 Garage R-13 Wall 90 Left 40 0 90 Roof Plan 1 2 R-38 Roof RB 2359 ATTIC r 01 l4 00 �'r ='D3 of 04 St _OS 06 07 Name V41 Construction ayr' sue. /t._/.,Roof_Risek --' Iko6fke,64cdnce X/ Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons" t w' " 4.._, F 0.1 0.85 Yes No WINDOWS f . 01 02 03 04 05 06 07 08 09 10 " Name YP Type Surface Orientation -Azimuth ( ) Width ft ( ) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Window Window Back Wall (Back-180) ---- ---- 1 18.0 0.34 0.24 Insect Screen (default) Window 2 Window Back Wall (Back-180) ---- --- 1 60.0 0.30 1 0.26 Insect Screen (default) Door Window Back Wall 2x6 (Back-180) 12.0 8.0 1 96.0 0.42 0.23 Insect Screen (default) Window 3 Window Right Wall (Right-270) ---- ---- 1 67.0 0.34 0.24 Insect Screen (default) French Door Window Right Wall (Right-270) 3.0 8.0 1 24.0 0.27 0.18 Insect Screen (default) Window 4 Window Front Wall (Front-0) 4.0 5.0 1 20.0 0.34 0.24 Insect Screen (default) Window 5 Window Left Wall (Left-90) --- ---- 1 26.0 0.30 0.26 Insect Screen (default) Window 6 Window Left Wall (Left-90) ---- ---- 1 50.0 0.34 0.24 Insect Screen (default) French Door 2 Window Left Wall (Left-90) 3.0 8.0 1 24.0 0.27 0.18 Insect Screen (default) Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml CF1 R-PRF-01 Page 5 of 9 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 2 Front Wall 24.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Door 10 0.1 10 10 1 0 0 0 0 0 0 0 0 French Door 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 4 5 0.1 °t 6 6 0 0 0 0 0 0 0 0 0 French Door 2 10 0.1 10 10 1 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS ��`. �. 0102 �' :. 03 .' 04 05� 06 Construction Name Surface Type ) f �: Constructior Type" " Framing "`-' To'tal CavityR val uZ V Assembly Layers ' Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Tile Gap: present Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: 10 PSF (Rooffile) r Inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 R-38 Roof RB Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R- 13 / 2x4 R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/Frame: R-19/2x6 R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 Garage R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: Wood Siding/sheathing/decking Registration Number: 214-No132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml CF1 R-PRF-01 Page 6 of 9 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Covered Slab Plan 1 2 2359 242 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Required 1179.5 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW 4- Standard DHW Heater 1 1 .0% WATER HEATERS /� l'g.'-f e`( t r l 01 02j• ,ter �v -1P' /. �,r .-1 ..04 :. 05__.. 06 07 08 Name Heater Element Type Tank Type Tank'Volume (gal) Energy F ctor-orA Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 ' —Natural Gas Small Storage 50 0.62 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 Name System Type Heating System Name Ducted Cooling System Name Ducted Distribution System Fan System Floor Area Served Res HVAC1 Other Heat/Cool Heating Component 1 Yes Cooling Component 1 1 Yes Air Distribution System 1 2359 Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 Calculation Datel'Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml CF1 R-PRF-01 Page 7 of 9 HVAC -HEATING SYSTEMS .. , 01. 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE ` HVAC - COOLING SYSTEMS 01 02 -03 04 05 06 07 _ Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 g p SplitAirCond - Split air conditioning 12.5 - 15 No No Cooling Component system.. 1-hers-cool HVAC COOLING - HERS VERIFICATION �- 01 ; 02i't_ 03 Oq 05 - 06 Name R Verified Airflow?_, ' •'"•v-r - Airflow Target a Verified EER aw +mow [ Verified SEER Verified Refrigerant Charge g Cooling Component 1-hers-6001' Required 4 _,M{ } .3..5„0 ,x SFequired .'Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 `, 05 06 07 08 Name A,Duct Supply Duct .. Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1. Ducts located in attic Sealed and tested .r 6 Attic Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION -HEIRS VERIFICATION 01" 02.. ` . -. :' 03 04 05 06 0 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return. Supply Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required q Not Required q. Not Required q --- 7 . Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 t ' HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance _ Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22 T CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml CFI R-PRF-01 Page 8 of 9 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS.- HERS VERIFICATION 01 02 03 Name Verified FanWatt Draw Required Fan Efficiency (Watts/CFM HVAC Fan 1-hers-fan Required 1 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM _ IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 61.09 0.25 Default 0 Required Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml CF1 R-PRF-01 Page 9 of 9 DOCUMENTATION'AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains �G"`�✓�acscd Company: Signature Date: Heritage Energy Group 2014-11-04 21:48:48 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949 584 1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility. for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system.design features identified.on this�Certificate of.Compliance,are.consistent.with the information provided on other applicable compliance documents, worksheets, calculations, plans and eciGtions submit`�'ted,t ee a foreement age cy fo ;appro wi h tfiis build rg permit application. Responsible Designer Name: Responsible Designer Signature: "Alex Gonzales° Company: Kx . , - `' Date Signed: " GHA Companies �'"" 2014-11-04 22;02.48 Address: License: 30-875 Date Palm Drive `' N/A City/State/Zip: Phone: Cathedral City, CA 92234 (760) 969-1400 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22 CERTIFICATE OF COMPLIANCE. RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 041 2014 Page 1 of 9 Calculation Description: Title 24 Analysis Input File Name: 131.74UP1 M.xml _ GENERAL INFORMATION" ti 01' Project Name Plan 1 M ' 02 Calculation Description ,Title 24 Analysis - 03 Project Location Darby Lane, 04 A City La Quinta 05 Standards Version ,Compliance 2014 `w _ 06 r ' Zip code 07 Compliance Manager Version, 'BEMCmpMgr 2013-3 (651) 08 _ Climate Zone CZ15 09 - Software Version 'EnergyPro 6.3 " 10 b Building Type Single Family 11 Front Orientation (deg/Cardinal) ,Cardinal 12 . Project Scope Newly Constructed 13 Number of Dwelling Units ,1 - 14 Total Cond. Floor Area (FT2) 2415 '15 Numl er of Zones, 16 Slab Area (FT2) 2415 17 Number of Stories 1', 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 ; Addition Slab -Area (FTZ) N/A :. 21 Glazing Percentage (%) 16.1 % ` COMPLIANCE RESULTS ��{�'`�w/�s r�}ram w `�'-• �w�.. Ixl, �:r` .•+�' . s, "A'.. 01 Building Complies with Coni titer Perfo mr ance� y. , �s :'AM-1701 02 This buildin incor orates features4that re uve fietes4n and/orwenfication by a certified HERS'trater underttFieupervision of a CEC-approved HERS provider. , 9 P 4 9� _ 4•-v! tat' 03 This building incor orates one ormore S ecial Features shown below ' o Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:25:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD - Project Name: Plan I Calculation Date/Time: 20:23; Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1M.xml e • CF1 R-PRF-01 ~ `Page 2 of 9 ENERGY USE SUMMARY_ . Energy Use Standard Proposed, • Compliance Percent (kTDV/ft2-yr) Design Design Margin. Improvement Space Heating 1.22 2.36 1.14 93.4% ° - Space Cooling �. 98.70 ` 96.77 . - 1.93 ., �; 2.0% _ - IAQ Ventilation - 1.14 1.14 0.00 0.0% Water Heating ' ' 11.08 : 10.06 1.02' . 9.2% PV Credit 0.00 .. 0.00 -- North Facing Compliance Total ,, 112.14 110.33 1.81' 1.6% Space Heating 1.22 2.56 .-1.34 -109.8% ! Space Cooling 98.70 i' 96.15 _ 2.55 2.6% IAQ Ventilation 1.14 1.14 _ 0.00 0.0% Water Heating r 11.08' r t.- 10.06 ` s=. ' •,` 1.02 9.2% 'r : <� . .. r PV Credit s -- 0.00 ' 0.00 _= East Facing Compliance Total 112.14 ' - 109.91, `' 2.23 '' 2.0% ' Space Heating 1 22 2-92 s tx i . Lgp ,e� rj kiasx Space Cooling 98 7s07 4�r �96.51�, _ IAQ Ventilation' 1 1i-A�4,�,�� -1.70 2.19 0.00 =139.3% 2.2% , ° Water Heating tr 118' �� 006i_� 1.02 9.2% PV Credit. - a '� :.... 3.• ;:� ., _ � �.. ,� , '+� 0.00 0.00 . . • =' South Facing Compliance Total '• 112.14 •110.63 , ` t - .. 1.51 �- r 1.3% ,.-_ -- - - n ..,.• Space Heating?' 1.22 ' ' 2.47 -1.25 -102.5% -Space Cooling 98.70 93.26 5.44 5.5% IAQ Ventilation 1.14 ` 1.14 • 0.00 - 0.0% Water Heating-- 11.08 10.06 1.02 9.2% ' PV Credit - 0.00 0.00 - West Facing Compliance Total - ' ' - 112.14 106.93 _ _ 5.21 4.6% Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 s � • HERS Provider: CaICERTS inc. Report Generated at: 2014-11-04 20:25:55 ti ' CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1M Calculation Date/Time: 20:23, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1Kxml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins CFI R-PRF-01 Page 3 of 9 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • Building Envelope Air Leakage • IAQ mechanical ventilation Cooling System Verifications: Verified EER Verified SEER • Refrigerant Charge r • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: " • --None -- ENERGY DESIGN RATING xis 0,r�{ % s This is the sum of the annual TDV energy�Consumption for energy use components,included'in the;performance:compl ance app oa �h for tt4rStandard Design Building (Energy Budget) and the annual 4�ia%:.t�, i.. � TDV energy consumption for lighting and components not regulated by Title 24 Part6 (such as domestic appliances an -consume r.- electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system.', Reference Energy Use .,. "a. =Energy Design Rating ; _ Margin Percent Improvement Total Energy (kTDV/f2)• 156.77 155.26 - _ 1.51 1.0% ' includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 1M 2415 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Plan 1M 2 Conditioned Res HVAC1 2415 10 DHW Sys 1. Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R.10172014-651 Report Generated at: 2014-11-04 20:25:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1 M.xml CF1 R-PRF-01 Page 4 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft) Tilt(deg) Back Wall Plan 1M 2 R-13 Wall 180 Back 305 78 90 Back Wall 2x6 Plan 1M 2 R-19 Wall, 180 Back 195 96 90 Right Wall Plan 1M 2 R-13 Wall 270 Right 520 91 90 Right Wall 2 Plan 1M 2 R-19 Wall 270 Right 100 0 90 Front Wall Plan 1 M 2 R-13 Wall 0 Front 290 40 90 Left Wall Plan 1M 2 R-13 Wall 90 Left 688 85 90 Front Wall -Garage Plan 1M 2 Garage R-13 Wall 0 Front 212 0 90 Right Wall Garage Plan 1M 2 �•. Garage R-13 Wall 270 Right 69 0 90 Roof - Plan 1M 2 R-38 Roof RB 2415 ATTIC tE •,�a_ 01 05 06 07 Name t Constructiori' „' j�' �_ �, _ )#.'y,. RooYRise L _F '" ` " ' " Roof Reflectan_ ce M ��t - Roof E_mittance Radiant Barrier Cool Roof AtticAttis%Roof,Consy:f,1+'01 0.85 Yes No WINDOWS 01 '02 03 �..`. 04 05 06 07 08 09 10 Name Type rd, Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Window Window Back Wall (Back-180) ---- ---- 1 18.0 0.34 0.24 Insect Screen (default) Window 2 Window Back Wall (Back-180) 12.0 5.0 1 60.0 0.30 0.26 Insect Screen (default) Door Window Back Wall 2x6 (Back-180) 12.0 8.0 1• •96.0 0.42 0.23 Insect Screen (default) Window 3 Window Right Wall (Right-270) ---- ---- 1 67.0 0.34 0.24 Insect Screen (default) French Door Window Right Wall (Right-270) 3.0 8.0 1 24.0 0.27 0.18 Insect Screen (default) Window 4 Window Front Wall (Front-0) 4.0 5.0 2 40.0 0.34 0.24 Insect Screen (default) Window 5 Window Left Wall (Left-90) ---- ---- 1 26.0 0.30 0.26 Insect Screen (default) Window 6 Window Left Wall (Left-90) ---- ---- 1 35.0• 0.34 0.24 Insect Screen (default) French Door 2 Window Left Wall (Left-90) 3.0 8.0 1 24.0 0.27 0.18 Insect Screen (default) Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance ReportVersion - CF1R-10172014-651 Report Generated at: 2014-11-04 20:25:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1M.xml CF1 R-PRF-01 Page 5 of 9 OVERHANGS AND FINS - 01 02 03 04- 05 06 07 08 09 10 11 12'• 13 14 Overhang Left Fin r Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up� Dist R Bot Up Window 2 1.5 1.25 2 2 0 0 0 0 0 0 0 0 0 Door 10 0.1 10 10 1 0 0 0 0 0 0 0 0 French Door 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 4 5 0.1 6 6 0 0 0 0 0. 0 0 0 0 French Door 2 10 0.1 10 10 1 0 0 0 .. • 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01, 02 • 03 04 OS 06 Construction Name Surface Type , Construction Type" ' Framing Total Cavity R-value Assembly Layers Cavity/Frame: no insul. /2x4 Top Chrd *1R 'f -+2x4ZTop Cy horclofK Roof Truss @ 241- . 7, Roof Deck: Wood Siding/sheathing/decking Tile Gap: present' Attic Roof Cons Attic Roofs � , Wood Framed Ceilmg7}p.C,?� r none" - - •. Roofing: 10 PSF (RoofTile) "� 4r ram` l ` Inside Finish: Gypsum Board R-38 Roof RB �. Ceilings (below attic) , Wood Framed Ceiling r -" 2x4 @ 24 in. O.C. R 38 Cavit /Frame: R-9.1 /2x4 Over Floor Joists: R-28.9 insul. Inside Finish: Gypsum Board R-13 Wall Exterior Walls` ; "Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Cavity/Frame: R-13/2x4 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board ' Cavity /Frame: R-19 / 2x6 • R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C: R 19 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/ Frame: R-13 / 2x4 Garage R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: Wood Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Covered Slab Plan 1M 2 2415 242 None 0.8 No Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 CA Building Energy Efficiency Standards - 2013 Residential Compliance . Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-04 20:25:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1 M.xml CF1 R-PRF-01 Page 6 of 9 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Required 1207.5 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Tank Exterior Tank Volume Energy Factor or Insulation Standby Loss Name Heater Element Type Tank Type (gal) Efficiency Input Rating R-value (Fraction) DHW Heater 1 Neural Gas k.,,$mall Storage � 5.0 �0.62 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATIC`N .t�q 01 �,02 Jjf \; +'�_. ... %U3� „� -- < s 05 06 07 Name _r--,Pipe lnsulationi Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A f N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 " Name System Type Heating System Name Ducted Cooling System Name Ducted Distribution System Fan System Floor Area Served Res HVAC1 Other Heat/Cool Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 2415 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 l Report Generated at: 2014-11-04 20:25:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD •Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1 M.xml - CF1 R-PRF-01 Page 7 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Coolin Com onent 1 g P SplitAirCond - Split air conditioning 12;.5 15 No NoCooling. Component system 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name • Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS• ' - 01 02 �t; 03 04 05, 06 07 08 Name " A - r TYpe0,-. 1!4L Duct Leakag .. At+ +!; Insulation R Supply Duct ' 4 , , valuedtLocation Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Sealed and tested '"4 �6+r I Attic' .� "Attic None Air Distribution u Ar°:: System 1-hers-list _4�-` r.o-• 1 �+v�� :x �alv�-:.�" .•,r:.�-� �—'-•.f �' �-.a...-� kr� i�F a� �.v - HVAC DISTRIBUTION - HERS VERIFICATION75 . 01 02 I; 03 04 0506 07 Duct Leakage g r '' Verified Duct Design Low -leakage Name Verification • Duct Leakage Target (%) Verified Duct Location Return Supply Air Handler Air Distribution System 1-hers-dist Required � 6.0 Not Re uired q Not Re uired q Not Re uired q --- HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: • 2014-11-04 22:03:54 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-04 20:25:55 . -CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 M Calculation Description: Title 24 Analysis Calculation Date/Time: 20:23, Tue, Nov 04, 2014, Input File Name: 13174UP1 M.xml HVAC Fan 1-hers-fan Required 0.58 CF1 R-PRF-01 Page 8 of 9 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%a) HERS Verification DwellingUnit 61.65 0.25 Default 0 Required Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:25:55 CERTIFICATE OF. COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1M.xml CF1 R-PRF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATIONSTATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains !'a CG"`�✓�acsca Company: Signature Date: Heritage Energy Group . 2014-11-04 21:50:55 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949 584 1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system,design features identified.on-this Certificate of,Compliance.are.consistent-with the information provided on other applicable compliance documents, worksheets, calculations, plans ands ecifications submi` t d to the enfor ement agency ford app o al with this building permit application. Responsible Designer Name: �� F �"' -� Responsible Designer Signature: . Alex Gonzales ,rt-''j' Company: - - - ° ' Date Signed: GHA Companies 2014-11-04 22 03:54 Address: License: 30-875 Date Palm Drive �,+. N/A City/State/Zip: Phone: Cathedral City, CA 92234 (760) 969-1400 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-No132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:25:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD; ' Project Name: Plan.1X . - Calculation Date/Time: 20:43, Tue, Nov 04,.2014,' Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml CFIR=PRF-01 - Page 1 of.10 GENERAL INFORMATION-- '' 01 -Project Name Plan 1X - 02 Calculation Description Title 24 Analysis- a 03• �- ° • - .Project Location Darby Lane 04 A City La Quinta 05 , Standards Version Compliance 2014 06 - Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3.(651) + 08 Climate Zone CZ15 • 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 r Front Orientation (deg/Cardinal) Cardinal 12. 4 Project Scope Newly Constructed 13 Number of Dwelling Units 1 E .� 14 Total Cond. Floor Area (FT?) 2698 ; ;. 15 ` ' t Number of Zones 1 •.16 t Slab Area (FT2) 2698 417 . Number of Stories 1 -. 18 , Addition Cond. Floor Area N/A jam."' , 19 Natural Gas Available Yes 20 ,Addition Slab.Area (FT?) N/A 21 y Glaiing Percentage (%) 17.1% r COMPLIANCE RESULTS "�/M��I{p/y*j��' -1i ^^ (����� T ' 1 rj ' � _ .- }�1 ry/' f t w 3JJ1.�`7 ii'aity.L I! • , , t `01 • Buildin Com lies with Com uter Performance; M '� ' �' ,rd. • 02 This building incorporates features that'require=fell testing'yand/or'venfiCaton by a certified HERS rates urde��t�he�upervision of a CEC-approved HERS provider. _ '•03 This building incorporates one or more Special}Featu�e"s shown below - qV - , ,. ± s ..: • ..v � ,,,,. :... s ,.. .� � .t Yy • w � •,. _� •� .•, a N- , « •.. ♦ `+ Registration Number: 214-No132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaiCERTS inc. CA Building Energy. Efficiency Standards 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17; CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml CFI R-PRF-01 Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.39 2.40 -1.01 -72.7% Space Cooling 99.24 97.73 1.51 1.5% IAQ Ventilation 1.07 1.07 0.00 0.0% Water Heating 10.05 9.12 .0.93 9.3% PV Credit ---- 0.00' 0.00 -- North Facing Compliance Total 111.75 110.32 1.43 1.3% Space Heating 1.39 2.50 -1.11 -79.9% Space Cooling 99.24 93.63 5.61 5.7% IAQ Ventilation 1.07 1.07 0.00 0.0% Water Heating 10.05 9.12 0.93 9.3% PV Credit i 0.00 0.00 East Facing Compliance Total ` 111.75 106.32 5.43 4.9% Space Heating 1 39 . Space Cooling ;_" 99 24. IAQ Ventilation 1.07, ',., 2<92 96.98 i 1 07 -1.53 2.26 ' 0.00 -110.1% 2.3% wl Water Heating ; _ /�L4 1:< L `710,05,.' �7 �" 9,.12r ,: 0.93 0.0% 9.3% �.a PV Credit ..ti -" r 0:00 0.00 ---- South Facing Compliance Total- 111.75 110.09 1.66 1.5% Space Heating 1.39 2.37 -0.98 -70.5% Space Cooling 99.24 91.09 8.15 8.2% IAQ Ventilation 1.07 1.07 0.00 0.0% Water Heating 10.05 9.12 0.93 9.3% PV Credit 0.00 0.00 ---- West Facing Compliance Total 111.75 103.65 8.10 7.2% Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014 'Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins CF1 R-PRF-01- Page 3of 10 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: ' • Building, Envelope Air Leakage • IAQ mechanical ventilation Cooling System Verifications: • ` • Verified EER • Verified SEER , • Refrigerant Charge • Fan Efficacy Watts/CFM k - - HVAC Distribution System Verifications: Duct Sealing id , Domestic Hot Water System Verifications • --None u w �i:�.r.._V:- ;/rci! .�.Y::Y Y- a :c'�t_�.. e�•-i -�..f.v. 3-4 t.c.,. �•::�:.ry ,.s,r,-.... ENERGY DESIGN RATING This is the sum of the annual .TDV energy consumption for energy use components'included'in the performance compliance approach,for tFie Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and compo en ni of regulated by Title 24tPart 6 (such as domestic appliances`and'consumer electronics) and accounting for the annual TDV energy offset by an on site renewable energy system. ,u ,� - "' " ?, -- . 'f; _r, ' .- .' �. �iaE . w7•'= •' ,r "` Reference Energy Use vi. `,.; Energy Design Ratirg'A, ;i± -: Margin ' Percent Improvement Total Energy (kTDV/f2)• T., i�'ti• �,.. 154.80- `%' _i n '' rx- 153.37 ti::: -, a #� '„ 1.43 o 0.9 /a kF' ` includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 •' 02 03 04 05 - 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 1X 2698 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling. Height Water Heating System 1 Water Heating System 2 Plan 1X 2 Conditioned Res HVAC1 2698 10 DHW Sys 1 Registration Number: 214-1\10132969A-00o000000-0000 Registration Date/Time: 2014-11-0422:04:34 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-10172014-651 HERS Provider: CalCERTS inc. Report Generated at: 2014-11-04 20:46:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis _ Input File Name: 13174UP1X.xml CF1 R-PRF-01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area(ft) ' Window Area (ft) Tilt(deg) Back Wall Plan 1X 2 R-13 Wall 180 Back 305 78 90 Back Wall 2x6 Plan 1X 2 R-19 Wall 180 Back 195 96 90 Right Wall Plan 1X 2 R-13 Wall 270 Right 720 135 90 Right Wall 2 Plan 1X 2 R-19 Wall 270 Right 100 0 90 Front Wall Plan 1X 2 R-13 Wall 0 Front 90 20 90 Left Wall Plan 1X 2 R-13 Wall 90 Left 888 107.997 90 Front Wall -Garage Plan 1X 2 Garage R-13 Wall 0 Front 208 0 90 Right Wall Garage Plan 1X 2 Garage R-13 Wall 270 Right 29 0 90 Front Wall 2 Plan 1X 2 l R-19 Wall 0 Front 200 25 90 Roof Plan 1X 2 R-38 Roof RB 2698 ATTIC 77- 01 03,40T `f ¢ `"0f / . % 04 w� 0; _ _ , . 05 06 07 Name > e Coristr`ucti6 i;k- -Rise" i Rdof Refflectence frRooffrnittance Radiant Barrier Cool Roof Attic ',Attid Roof Cons ` " 4 "F " `` 0.1 "` 0.85 Yes No Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name:13174UP1X.xml CF1 R-PRF-01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Window Window Back Wall (Back-180) ---- -- 1 18.0 0.34 0.24 Insect Screen (default) Window 2 Window Back Wall (Back-180) 12.0 5.0 1 60.0 0.30 0.26 Insect Screen (default) Door Window Back Wall 2x6•(Back-180) 12.0 8.0 1 96.0 0.31 0.23 Insect Screen (default) Window 3 Window Right Wall (Right-270) 13.4 5.0 1 67.0 0.34 0.24 Insect Screen (default) French Door Window Right Wall (Right-270) 3.0 8.0 1 24.0 0.27 0.18 Insect Screen (default) Window 4 Window Right Wall (Right-270) 4.0 5.0 1 20.0 0.34 0.24 Insect Screen (default) French Door 2 Window Right Wall (Right-270) ---- ---- 1 24.0 0.27 0.18 Insect Screen (default) Window 5 Window Front Wall (Front-0) 4.0 5.0 1 20.0 0.34 0.24 Insect Screen (default) Window 6 Window t Left Wall (Left-90) ---- ---- 1 26.0 0.30 0.26 Insect Screen (default) Window 7 Window 4�Left Wall (Left-90) 11.8 5.0 0.983 58.0 0.34 0.24 Insect Screen (default) French Door 3 Window Left Wall (Left-90) ..�.... 3.0 8.0 1 24.0 0.27 0.18 Insect Screen default ( ) Window 8 Window _ ` 1` ^ Fpnt,W!ll.2 (Front-0) 14.0_ r is S.Of 1.25 25.0 0.34 0.24 Insect Screen default OVERHANGS AND FINS /tMe{fir.. 01 ,`02 ' '� ' 03 ; - 04 `. 05 06 T 07' `' 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth r Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 2 1.5 1 3 3 0 0 0 0 0 0 0 0 0 Door 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 3 1.5 1 3 3 0 0 0 0 0 0 0 0 0 French Door 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 4 1.5 1 3 3 0 0 0 0 0 0 0 0 0 Window 5 5 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 7 1.5 1 3 3 0 0 0 0 0 0 0 0 0 French Door 3 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 8 5 0.1 6 6 0 0 0 0 0 0 0 0 0 Registration Number: 214-N0132969A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-11-04 22:04:34 Report Version - CF1R-10172014-651 HERS Provider: CaiCERTS inc. Report Generated at: 2014-11-04 20:46:17 • CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1X Calculation Description: Title 24 Analysis Calculation Date/Time: 20:43, Tue, Nov 04, 2014 Input File Name: 13174UP1X.xml CF1 R-PRF-01 Page 6of10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Tile Gap: present Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: 10 PSF (RoofTile) • Inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 R-38 Roof RB Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/ Frame: R- 13 / 2x4 R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/Frame: R-19/2x6 R-19 Wall Exterior Walls`. Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 Garage R-13 Wall Exte iio-FW5lls vWood,Framed>Wall .V h -1k2z41@X16°ui�Q:C''t F M Y R 13 Exterior Finish: Wood Siding/sheathing/deckin g r I i /, + SLAB FLOORS f It m V " k �! w--," e7+St r�°t 01 '` 102 ` . i Z 03 „ll.. 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Covered Slab Plan 1X 2;' 2698 282 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Required 1349.0 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 1 .0% Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml CFI R-PRF-01 Page 7 of 10 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.62 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A N/A N/A N/A N/A N/A HVAC SYSTEMS ) 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name ISyst" pe 7 Name 7'_ - Ducted '_7 VyrNaImT"e Ducted System Fan System Served Res HVAC1 4 � j r JOther HeaUCool . ; Heating Component 1� Yes ` �* Cooling•Component 1 Yes Air Distribution 2698 .1 . Nr pry. / it fit; System 1 HVAC - HEATING SYSTEMS 01 r' 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 12.5 7 15 No No Cooling Component system 1-hers-cool Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17 CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1X - Calculation Date/Time: 20:43, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml CFI R-PRF-01 Page 8 of 10 HVAC COOLING -HERS VERIFICATION ' 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified RefrigerantCharge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07. 08 Name ` Type Duct Leakage Insulation R-value Supply Duct Location Return Duct Bypass Duct - HERS Verification Air, Distribution System 1 Ducts located in attic Sealed and tested 6 - Attic • Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION + 01 � 02 '+ 03 04 05 06 07 Duct L-eakage r Verified Duct Design Low -leakage Name Verification ~ ? ; Duct Leakage Target (%) Tia. Verified -Duct Location_ Return Supply Air Handler Air Distribution System + , 1-hers-dist dr IRe uire 6 0 zf�r... •�-.,: Not Required Not Required /,.r� HVAC-FAN SYSTEMS -+ 01 02 03 04' Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency y (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 IAQ Recovery Name IAQ CFM IAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification DwellingUnit 64.48 0.25 Default . .0 Required Registration Number: 214-No132969A-000000000-Q0o0 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaiCERTS inc. �CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Plan 1X 1, Calculation Date/Time: 20:43, Tue, Nov 04, 2014 Page 9 of 10 Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xm1 ` r °'. > � �� .. !i gw�� y9 "-., � if�wy z"r'*� 3 � ,,,y �� '� � .��''s"� h . • — � a � • _ ( "p $ �� '"'�P .� t:��y�CTT�, t �+f fe i.` R•�. y ,•,.hcr. •'^r(�. .. � , f J ' � • � 4fyy . -' "9'" •y�.. �+�' � 4 £- , z�- t�-•���'N'"_n y�,C, _ a f y'• i'. r r-,sj fir - - '• ., � r ♦ , . • � sue, �•-';,y e.*3 :, ,i .- ! .. , t.. ) • _ � ' fit{ +.f • • } a - ' Registration Number: 214-N0132969A-000000000-0000 Registration. Date/Time: 2014-11-04 22:04:34 - HERS Provider: CaICERTS inc. ' CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version CF1R 10172014-651 Report Generated at: 2014-11-04 20:46:17 CERTIFICATE OF COMPLIANCE: RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1X Calculation DatelTime: 20:43, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml r CF1R-PRF-01'. Page 10 of 10 DOCUMENTATION. AUTHOR'S DECLARATION STATEMENT ;. 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains- Company: Signature Date: Heritage Energy Group 2014-11-04 21:52:49 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA92618 _ �. 949 584 1052 , RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: •.1. _ 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. ' 2. 1 certify that the energy featuies and performance specifcations identified on this Certificate of Compliance conform to the requirements Title 24, Part 1 Part 6 the California Code " of and of of Regulations. 'The 3. building design features or system design features identified on this Certificate of Compliance.: are. consistent -with the information rovided on other a licable com liance documents, it, worksheets, calculations, plans an clspe_cifications submitted to<the enforcement a e approval with this building permit application. ' pcy;for Res onsible Designer Name: P 9 RR6ssp6Hsible Designn6ir Signature .- �+ Alex Gonzales '> ..`_ �Peai�asteaeea Company:s.� Date Signed' .. - n GHA Companies ,.��„ 2014-11-04 22:04':34. Address: t ice L 'n se:. ^� 30-875 Date Palm Drive N/A' • ' ` City/State/Zip: Phone: Cathedral City, CA 92234 (760) 969-1400 . Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. , Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: ` CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance ,Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml CF1 R-PRF-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Plan 2 02 Calculation Description Title 24 Analysis 03 Project Location 'Darby Lane 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2709 15 Number of Zones 1 16 Slab Area (FT2) 1418 . 17 Number of Stories 2 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FT2.) N/A 21 Glazing Percentage (%) 17.0% COMPLIANCE RESULTS 01 Building Complies with Com uter Performances' 02 This building incorporates features thafyrequire' field testing and/or venfication by a certified HERS`rater under',the�supervision of a CEC-approved HERS provider. 03 This building incorporates one or mope Sliecial features shown below N Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R'-PRF-01 Project Name: Plan 2 Calculation Description: Title 24 Analysis Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Input File Name: 13174UP2.xml Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ftz-yr) Design Design Margin Improvement Space Heating 1.77 2.73 -0.96 -54.2% Space Cooling 98.93 94.92 4.01 4.1% IAQ Ventilation 1.19 1.19 0.00 0.0% Water Heating 10.01 9.09 0.92 9.2% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 111.90 107.93 3.97 3.5% Space Heating 1.77 2.88 -1.11 -62.7% Space Cooling 98.93 98.00 0.93 0.9% IAQ Ventilation 1.19 1.19 0.00 0.0% Water Heating 101.01 9.09 0.92 9.2% PV Credit 0.00 0.00 East Facing Compliance Total . 111.90 111.16 0.74 0.7% Space Heating 1:77 120 Space Cooling - < 98.93 94:91 P 9 IAQ Ventilation +-- € 1.19 t 1y;19�,= -1.43 4.02 0.00 -80.8% 4.1% 0.0% Water Heating }fi Y# 10.01 = �, 0.92 9.2% PV Credit A9 0.00 w111.90 0.00 --- South Facing Compliance•Total"� 108.39 3.51 3.1% Space Heating ": 1.77 2.99 -1.22 -68.9% Space Cooling 98.93 94.71 4.22 4.3% IAQ Ventilation 1.19 1.19 0.00 0.0% Water Heating 10.01 9.09 0.92 9.2% PV Credit --- 0.00 0.00 ---- West Facing Compliance Total 111.90 107.98 3.92 3.5% Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins , CF1R-PRF-01 ' Page 3 of 10 HERS FEATURE SUMMARY f The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • Building Envelope Air Leakage • IAQ mechanical ventilation .Cooling System Verifications_: • Verified EER • Verified SEER •; Refrigerant Charge - • Fan Efficacy Watts/CFM' HVAC Distribution System Verifications:. - • .Duct Sealing Domestic Hot Water System Verifications:" -- None ENERGY DESIGN RATING 4,.rz1 dam' syr If i,n - T ` This is the sum of the annual TDV energy onsumptio forr energyuse components included i the performance c pliance app�roR �h5forethe Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and compo'n`ents not.regulated bymTitle 24, Part-6 (such as domesbcappliancesTand consumerelectronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. - ,... �r < .," "' rs':r« ., , w-..,-•s 4�;""n• "`,y Reference Energy Use '3 Energy Design Rating X ;) Margin Percent Improvement Total Energy (kTDV/f2)' 155.04"-}154 30 0.74 0.5% ' includes calculated Appliances and Miscellaneous Energy Use (AMEU) ( BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 2 2709 1 5 1 0 1 ZONE INFORMATION s 01: 02 -03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Plan 2 2 Conditioned Res HVAC1 2709 10 DHW Sys 1 Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 - Report Generated at: 2014-11-04 20:20:30 4 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml Y CFI R-PRF-01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05. 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg). Back Wall Plan 2 2 R-13 Wall 180 Back 560 125 90 Back Wall 2 Plan 2 2 R-19 Wall 180 Back 240 126 90 Right Wall Plan 2 2 R-13 Wall 270 Right 648 61 90 Right Wall 2 Plan 2 2 R-19 Wall 270 Right 100 0 90 Front Wall Plan 2 2 R-13 Wall 0 Front 564 64 90 Left Wall Plan 2 2 R-13 Wall 90 Left 783 83.5 90 Front Wall -Garage Plan 2 2 Garage R-13 Wall 0 Front 80 0 90 Right Wall Garage Plan 2 2 Garage R-13 Wall 270 Right 64 0 90 Front Wall-Garage6 Plan 2 2, R-19 Wall 0 Front 154 0 90 Roof Plan 2 2 R-38 Roof RB 1738 Raised Floor Plan 2 2 R-19 Floor Crawlspace 320 ATTIC `//1` 01 .�/02_0?iFa•!`V.+. Il'.a 03i F �04: 'a.:IIItr,W.U5 06 07 Name '11°Construction ,. J w,Roof Rise Roof Reflectance' Roof Emittance Radiant Barrier Cool Roof Attic -.--.--^Attic"Roof Cons_ 4 0.1 0.85 Yes No Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-'04 22:05:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml CF1 R-PRF-01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) _ Multiplier Area (ft) U-factor SHGC Exterior Shading Window. Window Back Wall (Back-180) ---- - 1 9.0 0.34 0.24 Insect Screen (default) Window 2 Window Back Wall (Back-180) ---- - 1 30.0 0.30 0.26 Insect Screen (default) Window 3 Window Back Wall (Back-180) ---- ---- 1 86.0 0.34 0.24 Insect Screen (default) SGD Window Back Wall 2 (Back-180) 12.0 8.0 0.5 48.0 0.31 0.23 Insect Screen (default) Window 4 Window Back Wall 2 (Back-180) 12.0 5.0 1 60.0 0.30 0.26 Insect Screen (default) Window 5 Window Back Wall 2 (Back-180) 12.0 1.5 1 18.0 0.34 0.24 Insect Screen (default) Window 6 Window Right Wall (Right-270) ---- ---- 1 28.0 0.34 0.24 Insect Screen (default) Window 7 Window Right Wall (Right-270) 6.6 5.0 1 33.0 0.34 0.24 Insect Screen (default) Window 8 Window (Front Wall (Front-0) 12.2 5.0 1 61.0 0.34 0.24 Insect Screen (default) Window 9 Window. Front Wall (Front-0) ---- ---- 1 3.0 0.30 0.26 Insect Screen (default) Window 10 Window Left Wa11 (L9W) M 1 33.5 0.30 0.26 Insect Screen (default) Window 11 Window d IX" 1'` Left'Wall Left-90 ,- � , ' r jp , _ ( F) . � .' ".� ' �8.0 k �- 5.l) 1.25 50.0 1 0.34 0.24 Insect Screen (default) OVERHANGS AND FINS k .�# { 1: '' �...� F .` T .4avF, 01 ' 62' �_103 '- 64 ` _ 057". 717, 7 06- 07 - 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth �- Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up SGD 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 4 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 5 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 7 1.5 1 3 3 0 0 0 0 0 0 0 0 0 Window 8 1 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 11 1.5 1 3 3 0 0 0 0 0 0 0 0 0 Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 Project Name: Plan 2 Calculation Description: Title 24 Analysis Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Input File Name: 13174UP2.xml Page 6 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Tile Gap: present Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: 10 PSF (RoofTile) • Inside Finish: Gypsum Board • Cavity / Frame: R-9.1 / 2x4 R-38 Roof RB Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R- 13 / 2x4 R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/Frame: R-19/2x6 R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 Garage R-13 Wall Exteri6FW51ls T7Wood'FFaMed-Wall-r,7 -2z4-@\16!inYO-C--S j R 13 Exterior Finish: Wood Siding/sheathing/decking F 1+ Floor Surface: Carpeted •gFloor Deck: Wood Siding/sheathing/decking R-19 Floor Crawlspace Floors'IOJer C {awlsp Wood Frame/Flo ,/'@ 24 ir�O.0 RA19� I Cavity/Frame: R-19 /2x8 SLAB FLOORS ..-- 01 02 03 04 05 06 07 Name Zorie. ; Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Covered Slab Plan 2 2 - 1418 152 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Required 1354.5 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 1 .0% Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis' Input File Name: 13174UP2.xml CF1 R-PRF-01 Page 7 of 10 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R_-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.62 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name Sy Ist pe Name x _ '`, Ded uct Name Ducted System Fan System Served Res HVAC1 r+ Other HeaUCool /j. # o '-� ` Heating Component 1 { ? [Yes /f n , t+ 'Cooling Gompon,ent 1 ` Yes Air Distribution 2709 it ,4 _' t ;� w s"'. y ..�,J ..a-.-4. 'lll� did' System 1 Y HVAC -HEATING SYSTEMS 01 , - 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification. Cooling Component 1 SplitAirCond - Split air conditioning 12.5 15 No No Cooling Component system 1-hers-cool Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml CF1 R-PRF-01 Page 8 of 10 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Name Type Duct Leakage Insulation R-value Supply Duct Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Sealed and tested 6 Attic Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION �. 01 02 03 04 05 06 07 Name Duct Leakage' Verification TargeT4, ' Verified Duct Design Low -leakage j )Jf��('fJ Duct Leakage r Verified -Duct. Location Return Supply Air Handler Air Distribution System dist Required f 6r--k .01-hers roj:R,e Zuired . Not Required Not Required^ HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 72.09 0.25 Default 0 Required Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml r 7,77,77 otj Registration Number: 214-NO132970A-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 CF1R,-PRF-01 Page 9 of 10 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 Calculation Date/Time: 20:18, Tue,`Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml - 1 CF1 R-PRF-01 Page 10 of 10 DOCUMENTATION: AUTHOR'S DECLARATION STATEMENT •' - �, 1. 1 certify that this, Certificate of Compliance documentation is accurate and complete: Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group . , - 2014-11-04 2.1:54:52 , Address: CEA/HERS Certification Identification (If applicable): ., 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949 584 1052• RESPONSIBLE PERSON'S DECLARATION STATEMENT 3 I certify the following under penalty of perjury, under the IavJsof•the State of California: 1.. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. c 2.: I certify that the energy features and pe;rformance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part land Part 6 of the California Code of Regulations.'t 3. The building design features or:system.design features dentifieed--oon-this Certificate of Compliance.arexonsistent-with the information provided on other applicable compliance documents, worksheets, calculations, plans and specification submitted to�the enfor agency f ppr a w t hi buihding cement permit application. Responsible Designer Name: w •k t�',. '�,'� may. #` �r F4 Responsible Designer Signature - �*'.•^r - ..�• Q1W Alex Gonzales ! �- t� i.. . >.. r . , _.-_:= Company:y Mz N Date Signed: ,.= a GHA Companies 2014-11-04 22:05:41 i Address:' f License: 30-875 Date Palm Drive • N/A City/State/Zip: Cathedral City, CA 92234 rPhone: 60) 969-1400 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for theaccuracy of the information. y Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014'11-04 22:05:41 HERS Provider: - CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CFiR-10172014-651 Report Generated at: 2014-11-04 20:20:30 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01' Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014 Page 1 of 9 Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml !' GENERAL INFORMATION - 01 Project Name Plan 2X 02 Calculation Description Title 24 Analysis 03 Project Location Darby Lane 04 A City La Quinta 05'' Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 t -10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 - Total Cond. Floor Area (FT2) 2709 15 Number of Zones 1 16 Slab Area (FT2) 1418 17 Number of Stories 2 - 18 Addition Cond. Floor Area N/A�, , 19 Natural Gas Available Yes " 20 Addition Slab Area (FT?) .; N/A f' ."21 • Glazing Percentage (%) 16.6% COMPLIANCE RESULTSJ1.0C Yw 01 Building Complies with Computer Performance}`•��4 � f,'..�,..�,-�,•-lei;� �:•,.�.s:�r� i6FY�r1���c'� !•�„�--„-•�� �rwt•:.r� Gtt:` " 02 This building incorporates`;features that 'regwre field testing"yand/oQenfication by a certified HERSlratet urid(5ti44s vision of a CEC-approved HERS provider. - - 03 This building incorporates one'or more `Speciali eatures shown below '' "' t ' f Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 - Report Generated at: 2014-11-04 20:51:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml CF1 R-PRF-01 Page 2 of 9 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.77 2.89 -1.12 -63.3% Space Cooling 98.31 94.60 3.71 3.8% IAQ Ventilation 1.19 1.19 0.00 0.0% Water Heating 10.01 9.09 0.92 9.2% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 111.28 107.77 3.51 3.2% Space Heating 1.77 2.95 -1.18 -66.7% Space Cooling 98.31 97.27 1.04 1.1 IAQ Ventilation 1.19 1.19 0.00 0.0%. Water Heating 10.01 9.09 0.92 9.2% PV Credit �: `. ---- 0.00 0.00 ---- East Facing Compliance Total 111.28 110.50 0.78 0.7% Space Heating 1:77 3:25�. -1.48 Space Cooling 8 31 94.92 � 3.39 IAQ Ventilation 1 - 1.19 0.00 -83.6% 3.4% 0.0% Water Heating%• 10r01 _ .. �. '.� �a'{ C-P 0.92 9.2% PV Credit - -- .. 0:00 0.00 --- South Facing Compliance -Total' 111.28 108.45 2.83' 2.5% Space Heating 1 1.77 3.06 -1.29 -72.9% Space Cooling \ 98.31 94.19 4.12 4.2% IAQ Ventilation 1.19 1.19 0.00' 0.0% Water Heating 10.01 9.09 0.92 9.2% PV Credit -- 0.00 0.00 ---- West Facing Compliance Total 111.28 107.53 3.75 3.4% J Registration Number: 214-No132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:51:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins CF1 R-PRF-01, Page 3 of 9 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. ' Building -level Verifications: • Building Envelope Air Leakage • IAQ mechanical ventilation Cooling System Verifications: _ • Verified EER r • Verified SEER • Refrigerant Charge ' • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: ` • Duct Sealing. . •... 1. Domestic Hot Water System Verifications: ; • --None - :� i• V 4,. Y x..air,f�.,•....4.3=rgYr-�.�.:r��r.W.:.rr.,. ENERGY DESIGN RATING` psi 3r.. • ,. 4 ..v8 A .1'.. -' _.._.,.-- This is the sum of the annual TDV energy consumption for energy use components included in the performance compliahce approach for the Standard Design Building (Energy Budget) and the annual ' TDV energy consumption for lighting and components not-regulated�by Title 24, Part 6 (such as domestic appliances an`d consume�.6 ec`tronics) and accounting for the annual TDV energy offset liy an � T s ��' •s 'lr. T .� ..,.+> ::;fif: ,� .tom E4 c rill on -site renewable energy system.i - - Reference Energy Use Energy Design Rating•'. _„ "VC= Margin Percent Improvement Total Energy (kTDV/f2)* 'ti j� 154.42 °-a: r. , „ 153 64 - t 0.78 0.5% * includes calculated Appliances and.Miscellaneous Energy Use'(AMEU) BUILDING - FEATURES INFORMATION 01 02. 0S. 04 05 06 - 07- Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 2X . 2709 1 5 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07' Zone Name ' ZonerType HVAC System Name Zone Floor Area (ft) - Avg. Ceiling Height Water Heating System 1. Water Heating System 2 •Plan 2X 2 Conditioned Res HVAC1 2709 10 DHW Sys 1 Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-04 20:51:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2X Calculation Description: Title 24 Analysis Calculation Date/Time: 20:49, Tue, Nov 04, 2014 Input File Name: 13174UP2X.xml CFI R-PRF-01 Page 4 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft) Tilt(deg) Back Wall Plan 2X 2 R-13 Wall 180 Back 800 240.5 90 Right Wall Plan 2X 2 R-13 Wall 270 Right 648 61 90 Right Wall 2 Plan 2X 2 R-19 Wall 270 Right 100 0 90 Front Wall Plan 2X 2 R-13 Wall 0 Front 564 64 90 Left Wall Plan 2X 2 R-13 Wall 90 Left 783 83.5 90 Front Wall -Garage Plan 2X 2 Garage R-13 Wall 0 Front 80 0 90 Right Wall Garage Plan 2X 2 Garage R-13 Wall 270 Right 64 0 90 Front Wall-Garage6 Plan 2X 2 R-19 Wall 0 Front 154 0 90 Roof Plan 2X 2 `t R-38 Roof RB 1738 Raised Floor Plan 2X 2 R-19 Floor Crawlspace 320 ATTIC /r Y /� A,. .__V i. 01 � i 0.7 0Y 04 t., ... 0 _05 06 07 Name Constr'uctionjtf k• =;/ Roof..Rise" _' "`Roof Reflectance,rf FjRoof Emittance Radiant Barrier Cool Roof Attic ' Attic Roof Cons - =' 4 0.1 0.85 Yes No WINDOWS 01 02 t 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Window Window Back Wall (Back-180) ---- ---- 1 13.5 0.34 0.24 Insect Screen (default) Window 2 Window Back Wall (Back-180) 9.0 5.0 1 45.0 0.30 0.26 Insect Screen (default) SGD Window Back Wall (Back-180) 12.0 8.0 1 96.0 0.31 0.23 Insect Screen (default) Window 3 Window Back Wall (Back-180) ---- ---- 1 86.0 0.34 0.24 Insect Screen (default) Window 4 Window Right Wall (Right-270) ---- ---- 1 28.0 0.34 0.24 Insect Screen (default) Window 5 Window Right Wall (Right-270) 6.6 5.0 1 33.0 0.34 0.24 Insect Screen (default) Window 6 Window Front Wall (Front-0) 12.2 5.0 1 61.0 0.34 0.24 Insect Screen (default) Window 7 Window Front Wall (Front-0) ---- 1 3.0 0.30 0.26 Insect Screen (default) Window 8 Window Left Wall (Left-90) - 1 33.5 0.30 0.26 Insect Screen (default) Window 9 Window Left Wall (Left-90) 8.0 5.0 1.25 50.0 0.34 0.24 1 Insect Screen (default) Registration Number: 214-No132971A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-11-04 22:06:44 Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-04 20:51:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 Project Name: Plan 2X Calculation Description: Title 24 Analysis Calculation Date/Time: 20:49, Tue, Nov 04, 2014 Input File Name: 13174UP2X.xml Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 2 10 0.1 10 10 1 0 0 0 0 0 0 0 0 SGD 10 0.1 10 10 1 0 0 0 0 0 0 0 0 Window 5 1.5 1 3 3 0 0 0 0 0 0 0 0 0 Window 6 1 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 9 1.5 1 3 3 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers r ��. f " +1 \ - )2x4 Top Chord of Roof russ @�24 in. 7 p - Cavity/Frame: no insul. /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Tile Gap: present Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofin 10 PS RoofTile �'':r`Cy C- ' ':. `c.i, d°"'t- `` = - �+'-K�.a`- '. f.. 1�1/s • Inside Finish: Gypsum Board • Cavity / Frame: R-9.1 / 2x4 R-38 Roof RB Ceilings-(below.attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Exterior Walls + Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/Frame: R-19/2x6 R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 Garage R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: Wood Siding/sheathing/decking • Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking R-19 Floor Crawlspace Floors Over Crawlspace Wood Framed Floor 2x8 @ 24 in. O.C. R 19 Cavity/Frame: R-19/2x8 Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:51:33 . r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2X _ Calculation Date/Time: 20:49, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml CFI R-PRF-01 Page 6 of 9 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated , Covered Slab Plan 2X 2 1418 152 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Required 1354.5 WATER HEATING SYSTEMS , 01 02 i_ 03 04 05 06 Name System Type,.*' Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 1 0% WATER HEATERS Ir����*F,r:.�.e 01 � ` 02 �1`tF'' )t +fin 03 ►i�"' .04 J. ai 05 , ' •�06' 07 08 Name Heater Element Type F Tank Type A 3r- Tank`Volume. + �t� 59 Energy Factoror - Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 - ^"TNatural Gas f. j` Small Storage 50 0:62 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys`1 - 1/1 N/A N/A N/A • N/A N/A N/A ' ` HVAC SYSTEMS ' 01 02 03 04 05 06 07 Name System Type Heating System Name Ducted Cooling System Name: Ducted Distribution System Fan System Floor Area Served Res HVAC1 Other Heat/Cool Heating Component 1T Yes Cooling Component 1 Yes Air Distribution System 1 2709 Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider:' - CaICERTS inc. Report Generated at: 2014-11-04 20:51:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2X Calculation DatetTime: 20:49, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis F Input File Name: 13174UP2X.xml -r CF1 R-PRF-01 Page 7 of 9 HVAC.-HEATING SYSTEMS �• 01 02 03 Name ? Type f Efficiency ' Heating Component 1, CntrlFurnace - Fuel -fired central furnace' 80 AFUE r HVAC - COOLING SYSTEMS 01 02 03 04 '' 05 06 • 07 Efficiency f Multi -speed Name : System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 r SplitAirCond - Splitcond - itioning' ditioning' ' 12.5 ; ' 15 No No, Conlin _ 9 Component . system - 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 :: .. - 03 04 05 06' Name y Verified Airflow =.r.+rrw...• Airflow Target .r> : w Verified EER y.v.•,.+► 4� Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool�Te*350`�`, Required Required Required HVAC -:DISTRIBUTION SYSTEMS �" �' f"5e+"'}'`�fj _"•` �x 01 - -02f'o. a 03hrbv�s� 04r"r "s+';05 06 07 08 Name Supply Duct ;Type a Duct Leakage Insulatiori R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic '' Sealed and tested 6 Attic Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 " Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply" Low -leakage Air Handler Air Distribution System ' 1-hers-dirt• Required 6.0 Not Required Not Re uired Not Required --- {. Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: ° ` 2014-11-04 22:06:44 CA Building Energy Efficiency Standards - 2013 Residential Compliance w Report Version - CF1R-10172014-651 HERS Provider: ' CaICERTS inc. Report Generated at: 2014-11-04 20:51:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml CFI R-PRF-01 Page 8 of 9 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 1 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 72.09 0.25 Default 0 Required Registration Number: 214-No132971A-000000000-0000 Registration Date/Time: 2014-11-0422:06:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:51:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml CF1 R-PRF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2014-11-04 21:57:19 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949 584 1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 1 3. The building design features or system -design features identified •on.this Certificate of Compliance.are.consistent-with the information provided on other applicable compliance documents, worksheets, calculations, plans and 'specifications subm ed-t to he a for ement age cy foru approval with this buihdhg permit application, pp p Responsible Designer Name: t Responsible Designer Signature:_' Alex Gonzales �Pe�ri�a�c¢aeea- Company: Date�Signed:- GHA Companies -� 2014-11-04 22:06:44 Address: License: 30-875 Date Palm Drive h`�t. ! N/A City/State/Zip: Phone: Cathedral City, CA 92234 (760) 969-1400 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-10172014-651 Report Generated at: 2014-11-04 20:51:33 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 1 Date 11/5/2014 System Name Res HVAC Floor Area 2,359 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 . COIL CFM Total Room Loads 1,264 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts , TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 25.584 2,t35 - 782 - 28,361 Total Output Btuh 89.000 0 Output Btuh/s tt 37.7 1,746 1,636 Cooling System 0 0 Output per System 46,500 0 0 0 0 Total Output Btuh 46,500 0 . 2,135 0 Total Output(Tons) 3.9 1,746 1,636 Total Output Btuh/s ft 19.7 Total output s ttrron 606.E 1 29,076 31.632 Air System CFM per System 1.680 HVAC EQUIPMENT SELECTION Airflow cfm 1,680 15/12/80% 31.981 7,489. 89,000 Airflow cfm/s ft 0.71 Airflow cfm/Ton 433.5 Outside Air % 0.0 % Total Adjusted System Output 31,981 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 7,489 89,000 Aug.3 PM I Jan 1 AM Outside Air cfm/s tt 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating,Peak 26 IF '69 IF Outside Air O O'cfm Supply Fan 1,680 cfm 69 OF 69 OF 105 IF Heating Coil t ' 104 IF ROOM a 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112178 IF 76 / 62 IF 76 / 62 OF 55 / 54 °F ==' Outside Air c�, 0 cfm Supply Fan Cooling Coil 56 / 54 IF 1,680 cfm 47.5 % ( ROOM 76162 IF 75 / 62 OF I EnergyPro 6.3 by EnergySoff User Number: 7244 RunCode: 2014-11-05T10:06:10 ID: 13174U Page 1 of 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 1 M Date 11/5/2014 System Name Res HVAC Floor Area 2,415 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,252 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Out ut erSystem 89,000 25,364 2,186 770 27.943 Total Output Btuh 89.000 0 Output Btuhfs ft 36.9 1.731 1,612 Cooling System 0 0 Output perSystem 46.500 01 0 0 0 Total Ou ut Btuh 46.500 01 2,186 0 Total Output(Tons) 3.9 1,731 1,612 Total Output Btuh/s ri 19.3 Total Output s riITon 623.2 1 28,826 31,167 Air System CFM per System 1,680 HVAC EQUIPMENT SELECTION Airflow cfm 1,680 15/12/80% 31,955 7,521 89,000 Airflow cfm/s ri 0.70 Airflow cfmfTon 433.5 Outside Air / 0.0 % Total Adjusted System Output 31,955 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 7.521 89,000 Aug 3 PM Jan 1 AM Outside Air cfm/s tt 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF 69 IF 0' Outside Air 0 cfm Supply Fan 1,680 cfm 69 OF 69 IF 105 OF Heating Coil 104 IF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Tem eratures at Time of Cooling Peak 112/78IF 76/62OF 76/62IF 55/54IF Outside Air c 0 cfm Supply Fan Cooling Coil 56 / 54 IF 1,680 cfm 47.5 i ( ROOM 76/62OF 75162IF EnergyPro 6.3 by Energ SoR User Number. 7244 RunCode: 2014-11-05T10:06:36 ID: 13174U Page 1 of 1 - M ± 7 J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 1X Date 11/5/2014 System Name Res HVAC Floor Area 2,698 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,453 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts - TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 29,196 2,442 871 31,484 Total Output Btuh 89,000 0 Output Btuh/s ft •33.0 1,992 1,816 Cooling System 0 0 Output per System 46,500 0 01 0 0 Total Output Btuh 46,500 0 2.442 0 Total Output(Tons) 3.9 1,992 1,816 Total Output Btuh/s tt 17.2 Total Output s f rron 696.3 1 33.1811 35,116 Air System CFM per System 1,680 HVAC EQUIPMENT SELECTION. Airflow cfm 1,680 15/12/80% 32,048 7.488 -89,000 Airflow cfm/s ft 0.62 Airflow cfm[Ton 433.5 Outside Air / 0.0 % Total Adjusted System Output 32,048 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 7,488 89,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF 69 IF Outside Air 0 cfm Supply Fan' 1,680 cfm 69 IF 69 IF 105 OF ' Heating Coil - 104 IF ROOM 70 IF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 IF 76 / 62 IF 76 l 62 OF 55 / 54 OF As 0' c Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 IF 1,680 cfm . 47.7 % ( ROOM 76162°F 75/62°F EnergyPro 6.36 EnergySoR User Number 7244 RunCode: 2014-11-05T10:09:06 ID: 13174U Page 1 o/ 1 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 2 Date 11/5/2014 System Name Res HVAC Floor Area 2,709 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,468 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System .89,000 29,799 _ 2,866 829 - 30,203 Total Output Btuh 89.000 0 Output(Btu h/s tt 32.9 1,649 1,340 Cooling System 0 0 Output perS stem 46,500 0 0 0 0 Total Output Btuh 46,500 0 2,866 0 Total Out ut(Tons) 3.9 1,649 1,340 Total Output Btuh/s tt 17.2 Total Output s ft/Ton 699.1 1 33,0981 32,884 Air System CFM perSystem 1,680 HVAC EQUIPMENT SELECTION Airflow cfm 1.680 15/12/80% 31.684 7,875 89,000 Airflow cfm/s ff 0.62 Airflow cfm/Ton 433.5 Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) ' TIME OF SYSTEM PEAK 31,684 7,875 89,000 Aug 3 PM Jan 1 AM Outside Air cfm/s tt 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF 69 IF Outside Air 0 cfm Supply Fan 1,680 cfm 69 IF 69 IF 105 IF Heating Coil 104 IF ROOM 70 IF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 ! 78. OF 76 / 62 IF 76 / 62 IF 55 / 54 IF Outside Air c 0 cfm Supply Fan Cooling Coil 1,680 cfm 76 / 62 OF 56 / 54 IF 48.1 % ROOM 75 / 62 IF EnergyPro6.3 b EnergySoR User Number. 7244 RunCode: 2014-11-OST10:09:46 ID: 13174U Page 1 of 1 f HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Plan 2X Date 11/5/2014 System Name Res HVAC Floor Area 2,709 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,463 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 29,699 2,866 830 30,249 Total Output Stuh 89,000 0 Output Btuh/s tt 32.9 1,644 1,343 CoolingSystem 0 0 Output per System / 46,500 01 0 _ 0 0 Total Output Btuh 46,500 0 2,866 0 Total Output(Tons) 3.9 1,644 1,343 Total Output Bluh/s tt 17.2 Total Output s ft/Ton 699.1 32,987 32,935 Air System CFM per System 1.680 HVAC EQUIPMENT SELECTION Airflow cfm 1,680 15/12/80% 31,680 7,878 89,000 Airflow cfm/s ft 0.62 Airflow cfmrron ` 433.5 - Outside Air % 0.0 % Total Adjusted System Output 31,680 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 7,878 89,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Heating Peak 26 OF 69 IF Outside Air C•~ 0 clm Supply Fan 1,680 dm 69 IF 69 IF 105 IF , Heating Coil 104 IF ROOM 70 IF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112178 IF 76 / 62 IF 76 / 62 IF 55 / 54 IF c , Outside Air c 0 clm Supply Fan Cooling Coil 56 / 54 IF 1,680 drn _ 48.1 % ROOM 76 / 62 OF 75 162 IF I EnergyPro 6.3 by EnergySoft User Number. 7244 RunCode: 2014-11.05T1O:10:34 ID: 13174U Page 1 or 1