Darby Estates TR 31087 (Plans 1 & 2) 2013 Codes - Title 244
I
Title 24 Energy Report
9 at D.'arb
La Quinta
Climate Zone #15
RF-CEIVED
NOV 0 6 2014
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
12013 Build in Energy'
ner Efficiency Standards
BEG Project No.: 13174U
GHA Companies
Len Nobel Company
Heritage Energy Group, LLC
November 4, 2014
Tel: (949) 789-7221 / Fax: (949) 789-7222
4 �r
CITY OF LA QUINTA
BUILDING &SAFETY cEPT.
APPROVED
"FOR CONSTRUCTION
DATIR 119 14 By .
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24. Analysis Input File Name: 13174UP1.xml
iy
CF1 R-PRF-01
Page 1 of 9
.GENERAL INFORMATION
01
Project Name
Plan 1
02
Calculation Description
Title 24 Analysis
03
Project Location
Darby Lane
04
A City
La Quinta
05
Standards Version
Compliance 2014
06
Zip code
07
Compliance Manager Version
BEMCmpMgr 2013-3 (651)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.3
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
2359
15
Number of Zones
1
16
Slab Area (FT2)
2359
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (FT2)
N/A
21
Glazing Percentage ("/o)
16.30%
COMPLIANCE RESULTS `' sk �•-+ `" 2,Ya €' Yr:,:
01
Building Complies with Computer PeIrfo mance
02
This building incorporates,features that �egwre;f'eld testing-anWor`venfication by a`certified HERS'ratTenunde Ft�he�supen!ision of a CEC-approved HERS
provider.
03
This building incorporates one or more SpecialFeatures shownbelow
Registration Number: 214-N0132967A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2014-11-04 22:02:48
Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-04 20:13:22
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml
kw
CF1 R-PRF-01
Page 2 of 9
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating 1.41
2.58
-1.17
-83.0%
Space Cooling 101.63
100.58
1.05
1.0%
IAQ Ventilation 1.16
1.16
0.00
0.0%
Water Heating 11.25
10.20
1.05
9.3%
PV Credit ----
0.00
0.00
--
North Facing Compliance Total 115.45
114.52
0.93
0.8%
Space Heating 1.41
2.66
-1.25
-88.7%
Space Cooling 101.63
99.60
2.03
2.0%
IAQ Ventilation 1.16
1.16
0.00
0.0%
Water Heating 11.25
10.20
1.05
9.3%
PV Credit ---
0.00
0.00
----
East Facing Compliance Total 115.45
113.62
1.83
1.6%
Space Heating '^ 1.4:1, 3 12
Space Cooling t s' 101: 3 4, 1 0:52'^
-1.71
-121.3%
IAQ Ventilation 1 16 a
r y16, Q °�
Water Heating1.125 r
10 20 { j. ff�
0.00
0.0%
�, ;�
PV Credit�'
_ r y
0.00
1.05
0.00
9.3%
South Facing Compliance Total' 115.45
115.00
0.45
0.4%
Space Heating ` 1.41
2.75
-1.34
-95.0%
Space Cooling v 101.63
96.38
5.25
5.2%
IAQ Ventilation 1.16
1.16
0.00
0.0%
Water Heating 11.25
10.20
1.05
9.3%
PV Credit ----
0.00
0.00
----
West Facing Compliance Total 115.45
110.49
4.96
4.3%
Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-04 20:13:22
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD -
Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml
a:
s
CFIR-PRF-01 '
Page 3 of 9
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. '
• Window overhangs and/or fins -
HERS FEATURE SUMMARY - W
The following is a summary of the features that must be field -verified by -a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• Building Envelope Air Leakage
• IAQ mechanical ventilation `
Cooling System Verifications: •, s ,;
;Verified EER _ e
Verified SEER
• Refrigerant Charge t �+
• Fan Efficacy Watts/CFM .
HVAC Distribution System Verifications: t r
• Duct Sealing
Domestic Hot Water System Verifications. ;-
.--None-. `.
. .. , �,,.tin..e�C,acr.. _ ��l,.i/..�:a .`�....��,� :�r:��,..�b�ss...:y-fan s�,bs�.K.,. r:-f�:w. r-•r:
ENERGY DESIGN RATING=y .-17 $1%rlxpf
;°� j
This is the sum of the annual TDV energyensumption forreenergy use componentsmcl�uded in the performance c*m pliance;app oachtfor the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by,Title 24, Part-6-(such-as
domestic appliances and consumerelectromcs) and accounting for the annual TDV energy offset by an
on -site renewable energy system. J ' `zr_ = ' ' "§ ` . r'` w,. �}
,T, , ^•.• ° ".:`
i
Reference Energy Use
Margin
Percent Improvement
Total Energy (kTDV/f2)"
'Sa ; 160.42.
j`.yt r fi' N 's159 97,_7.
0.45
0.3%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
. Number of Zones
, Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
- Plan 1
2359
1
4
1
0
1
ZONE INFORMATION
01
02
03
04
05
-06
07
`
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling.
Height
Water Heating System 1
Water Heating System 2
Plan 1 2`
Conditioned
Res HVAC1
2359 r
10.
DHW Sys 1
Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651' Report Generated at: 2014-11-04 20:13:22
f
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP1.xml
CF1 R-PRF-01
Page 4 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window Area (ft)
Tilt(deg)
Back Wall
Plan 1 2
R-13 Wall
180
Back
305
78
90
Back Wall 2x6
Plan 1 2
R-19 Wall
180
Back
195
96
90
Right Wall
Plan 1 2
R-13 Wall
270
Right
520
91
90
Right Wall 2
Plan 1 2
R-19 Wall
270
Right
100
0
90
Front Wall
Plan 1 2
R-13 Wall
0
Front
90
20
90
Left Wall
Plan 1 2
R-13 Wall
90
Left
688
100
90
Front Wall -Garage
Plan 1 2
Garage R-13 Wall
0
Front
412
0
90
Right Wall Garage
Plan 1 2
Garage R-13 Wall
270
Right
69
0
90
Left Wall 2
Plan 1 2
Garage R-13 Wall
90
Left
40
0
90
Roof
Plan 1 2
R-38 Roof RB
2359
ATTIC
r
01
l4 00 �'r
='D3 of
04 St
_OS
06
07
Name
V41 Construction ayr' sue.
/t._/.,Roof_Risek
--' Iko6fke,64cdnce X/
Roof Emittance
Radiant Barrier
Cool Roof
Attic
Attic Roof Cons" t w'
" 4.._,
F 0.1
0.85
Yes
No
WINDOWS f .
01
02
03
04
05
06
07
08
09
10 "
Name
YP
Type
Surface Orientation -Azimuth
( )
Width ft
( )
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
Window
Window
Back Wall (Back-180)
----
----
1
18.0
0.34
0.24
Insect Screen (default)
Window 2
Window
Back Wall (Back-180)
----
---
1
60.0
0.30
1 0.26
Insect Screen (default)
Door
Window
Back Wall 2x6 (Back-180)
12.0
8.0
1
96.0
0.42
0.23
Insect Screen (default)
Window 3
Window
Right Wall (Right-270)
----
----
1
67.0
0.34
0.24
Insect Screen (default)
French Door
Window
Right Wall (Right-270)
3.0
8.0
1
24.0
0.27
0.18
Insect Screen (default)
Window 4
Window
Front Wall (Front-0)
4.0
5.0
1
20.0
0.34
0.24
Insect Screen (default)
Window 5
Window
Left Wall (Left-90)
---
----
1
26.0
0.30
0.26
Insect Screen (default)
Window 6
Window
Left Wall (Left-90)
----
----
1
50.0
0.34
0.24
Insect Screen (default)
French Door 2
Window
Left Wall (Left-90)
3.0
8.0
1
24.0
0.27
0.18
Insect Screen (default)
Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP1.xml
CF1 R-PRF-01
Page 5 of 9
DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door 2
Front Wall
24.0
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Door
10
0.1
10
10
1
0
0
0
0
0
0
0
0
French Door
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 4
5
0.1 °t
6
6
0
0
0
0
0
0
0
0
0
French Door 2
10
0.1
10
10
1
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
��`. �.
0102
�'
:. 03
.' 04
05�
06
Construction Name
Surface Type
) f �: Constructior Type"
" Framing "`-'
To'tal CavityR val uZ
V Assembly Layers
'
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of
Roof Deck: Wood Siding/sheathing/decking
Roof Truss @ 24 in.
Tile Gap: present
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: 10 PSF (Rooffile)
r
Inside Finish: Gypsum Board
• Cavity/Frame: R-9.1 /2x4
R-38 Roof RB
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R- 13 / 2x4
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/Frame: R-19/2x6
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
Garage R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Exterior Finish: Wood Siding/sheathing/decking
Registration Number: 214-No132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP1.xml
CF1 R-PRF-01
Page 6 of 9
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Covered Slab
Plan 1 2
2359
242
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Required
1179.5
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
4-
Standard
DHW Heater 1
1
.0%
WATER HEATERS /� l'g.'-f
e`( t r l
01
02j•
,ter �v
-1P' /.
�,r
.-1 ..04 :.
05__..
06
07
08
Name
Heater Element Type
Tank Type
Tank'Volume
(gal)
Energy F ctor-orA
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
' —Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
N/A
N/A
N/A
N/A
N/A
N/A
HVAC SYSTEMS
01
02
03
04
05
06
07
Name
System Type
Heating System
Name Ducted
Cooling System
Name Ducted
Distribution
System
Fan System
Floor Area
Served
Res HVAC1
Other Heat/Cool
Heating Component 1
Yes
Cooling Component 1 1
Yes
Air Distribution
System 1
2359
Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 Calculation Datel'Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml
CF1 R-PRF-01
Page 7 of 9
HVAC -HEATING SYSTEMS .. ,
01.
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE `
HVAC - COOLING SYSTEMS
01
02
-03
04
05
06
07
_ Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
g p
SplitAirCond - Split air conditioning
12.5
-
15
No
No
Cooling Component
system..
1-hers-cool
HVAC COOLING - HERS VERIFICATION �-
01
; 02i't_
03
Oq
05 -
06
Name
R Verified Airflow?_, '
•'"•v-r -
Airflow Target
a
Verified EER
aw +mow
[ Verified SEER
Verified Refrigerant
Charge
g
Cooling Component 1-hers-6001'
Required 4 _,M{
} .3..5„0 ,x
SFequired
.'Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
`, 05
06
07
08
Name
A,Duct
Supply Duct
..
Leakage
Insulation R-value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1.
Ducts located in attic
Sealed and tested
.r
6
Attic
Attic
None
Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION -HEIRS VERIFICATION
01"
02..
` . -. :' 03
04
05
06
0
Name
Duct Leakage
Verification
Duct Leakage Target (%)
Verified Duct Location
Verified Duct Design
Return. Supply
Low -leakage
Air Handler
Air Distribution System
1-hers-dist
Required
6.0
Not Required
q
Not Required
q.
Not Required
q
---
7 .
Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 t ' HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance _ Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22
T
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1.xml
CFI R-PRF-01
Page 8 of 9
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS.- HERS VERIFICATION
01
02
03
Name
Verified FanWatt Draw
Required Fan Efficiency (Watts/CFM
HVAC Fan 1-hers-fan
Required
1 0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Name
IAQ CFM
IAQ Watts/CFM
_ IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
DwellingUnit
61.09
0.25
Default
0
Required
Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 Calculation Date/Time: 20:11, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP1.xml
CF1 R-PRF-01
Page 9 of 9
DOCUMENTATION'AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Rudy Sains
�G"`�✓�acscd
Company:
Signature Date:
Heritage Energy Group
2014-11-04 21:48:48
Address:
CEA/HERS Certification Identification (If applicable):
470 Wald
City/State/Zip:
Phone:
Irvine, CA 92618
949 584 1052
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility. for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system.design features identified.on this�Certificate of.Compliance,are.consistent.with the information provided on other applicable compliance documents,
worksheets, calculations, plans and eciGtions submit`�'ted,t ee a foreement age cy fo ;appro wi h tfiis build rg permit application.
Responsible Designer Name:
Responsible Designer Signature:
"Alex Gonzales°
Company: Kx . , - `'
Date Signed: "
GHA Companies �'""
2014-11-04 22;02.48
Address:
License:
30-875 Date Palm Drive `'
N/A
City/State/Zip:
Phone:
Cathedral City, CA 92234
(760) 969-1400
Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 214-N0132967A-000000000-0000 Registration Date/Time: 2014-11-04 22:02:48 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:13:22
CERTIFICATE OF COMPLIANCE. RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 041 2014 Page 1 of 9
Calculation Description: Title 24 Analysis Input File Name: 131.74UP1 M.xml _
GENERAL INFORMATION" ti
01'
Project Name
Plan 1 M '
02
Calculation Description
,Title 24 Analysis -
03
Project Location
Darby Lane,
04
A City
La Quinta
05
Standards Version
,Compliance 2014 `w _
06
r ' Zip code
07
Compliance Manager Version,
'BEMCmpMgr 2013-3 (651)
08
_ Climate Zone
CZ15
09 -
Software Version
'EnergyPro 6.3 "
10
b Building Type
Single Family
11
Front Orientation (deg/Cardinal)
,Cardinal
12 .
Project Scope
Newly Constructed
13
Number of Dwelling Units
,1
- 14
Total Cond. Floor Area (FT2)
2415
'15
Numl er of Zones,
16
Slab Area (FT2)
2415
17
Number of Stories
1',
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
; Addition Slab -Area (FTZ)
N/A
:.
21
Glazing Percentage (%)
16.1 % `
COMPLIANCE RESULTS ��{�'`�w/�s r�}ram w
`�'-• �w�.. Ixl, �:r` .•+�' . s, "A'..
01
Building Complies with Coni titer Perfo mr ance� y. , �s :'AM-1701
02
This buildin incor orates features4that re uve fietes4n and/orwenfication by a certified HERS'trater underttFieupervision of a CEC-approved HERS provider. ,
9 P 4 9� _ 4•-v! tat'
03
This building incor orates one ormore S ecial Features shown below '
o
Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:25:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD -
Project Name: Plan I Calculation Date/Time: 20:23; Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1M.xml
e •
CF1 R-PRF-01 ~
`Page 2 of 9
ENERGY USE SUMMARY_ .
Energy Use
Standard
Proposed, •
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin.
Improvement
Space Heating 1.22 2.36
1.14
93.4%
° - Space Cooling �. 98.70 ` 96.77 .
- 1.93 ., �;
2.0%
_
- IAQ Ventilation - 1.14 1.14
0.00
0.0%
Water Heating ' ' 11.08 : 10.06
1.02'
. 9.2%
PV Credit 0.00 ..
0.00
--
North Facing Compliance Total ,, 112.14 110.33
1.81'
1.6%
Space Heating 1.22 2.56
.-1.34
-109.8%
! Space Cooling 98.70 i' 96.15 _
2.55
2.6%
IAQ Ventilation 1.14 1.14
_ 0.00
0.0%
Water Heating r 11.08' r t.- 10.06 ` s=.
' •,`
1.02
9.2% 'r : <�
. .. r
PV Credit s -- 0.00 '
0.00
_=
East Facing Compliance Total 112.14 ' - 109.91,
`'
2.23 ''
2.0% '
Space Heating 1 22 2-92
s tx i . Lgp ,e� rj kiasx
Space Cooling 98 7s07 4�r �96.51�, _
IAQ Ventilation' 1 1i-A�4,�,��
-1.70
2.19
0.00
=139.3%
2.2% ,
°
Water Heating tr 118' �� 006i_�
1.02
9.2%
PV Credit. - a '� :.... 3.• ;:� ., _ � �.. ,� , '+�
0.00
0.00
. .
• ='
South Facing Compliance Total '• 112.14 •110.63 , ` t -
..
1.51 �-
r
1.3%
,.-_ -- - - n ..,.•
Space Heating?' 1.22 ' ' 2.47
-1.25
-102.5%
-Space Cooling 98.70 93.26
5.44
5.5%
IAQ Ventilation 1.14 ` 1.14 •
0.00
- 0.0%
Water Heating-- 11.08 10.06
1.02
9.2%
' PV Credit - 0.00
0.00 -
West Facing Compliance Total - ' ' - 112.14 106.93 _ _
5.21
4.6%
Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651
s � •
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-04 20:25:55
ti '
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1M Calculation Date/Time: 20:23, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1Kxml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
CFI R-PRF-01
Page 3 of 9
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• Building Envelope Air Leakage
• IAQ mechanical ventilation
Cooling System Verifications:
Verified EER
Verified SEER
• Refrigerant Charge r
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications: "
• --None --
ENERGY DESIGN RATING xis 0,r�{ % s
This is the sum of the annual TDV energy�Consumption for energy use components,included'in the;performance:compl ance app oa �h for tt4rStandard Design Building (Energy Budget) and the annual
4�ia%:.t�, i.. �
TDV energy consumption for lighting and components not regulated by Title 24 Part6 (such as domestic appliances an -consume r.- electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.',
Reference Energy Use
.,.
"a. =Energy Design Rating ; _
Margin
Percent Improvement
Total Energy (kTDV/f2)•
156.77
155.26 - _
1.51
1.0%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1M
2415
1
4
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 1M 2
Conditioned
Res HVAC1
2415
10
DHW Sys 1.
Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R.10172014-651 Report Generated at: 2014-11-04 20:25:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1 M.xml
CF1 R-PRF-01
Page 4 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft)
Tilt(deg)
Back Wall
Plan 1M 2
R-13 Wall
180
Back
305
78
90
Back Wall 2x6
Plan 1M 2
R-19 Wall,
180
Back
195
96
90
Right Wall
Plan 1M 2
R-13 Wall
270
Right
520
91
90
Right Wall 2
Plan 1M 2
R-19 Wall
270
Right
100
0
90
Front Wall
Plan 1 M 2
R-13 Wall
0
Front
290
40
90
Left Wall
Plan 1M 2
R-13 Wall
90
Left
688
85
90
Front Wall -Garage
Plan 1M 2
Garage R-13 Wall
0
Front
212
0
90
Right Wall Garage
Plan 1M 2 �•.
Garage R-13 Wall
270
Right
69
0
90
Roof -
Plan 1M 2
R-38 Roof RB
2415
ATTIC tE •,�a_
01
05
06
07
Name
t Constructiori' „'
j�' �_ �, _ )#.'y,.
RooYRise
L _F
'" ` " ' "
Roof Reflectan_ ce M
��t -
Roof E_mittance
Radiant Barrier
Cool Roof
AtticAttis%Roof,Consy:f,1+'01
0.85
Yes
No
WINDOWS
01
'02
03
�..`.
04
05
06
07
08
09
10
Name
Type
rd,
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
Window
Window
Back Wall (Back-180)
----
----
1
18.0
0.34
0.24
Insect Screen (default)
Window 2
Window
Back Wall (Back-180)
12.0
5.0
1
60.0
0.30
0.26
Insect Screen (default)
Door
Window
Back Wall 2x6 (Back-180)
12.0
8.0
1•
•96.0
0.42
0.23
Insect Screen (default)
Window 3
Window
Right Wall (Right-270)
----
----
1
67.0
0.34
0.24
Insect Screen (default)
French Door
Window
Right Wall (Right-270)
3.0
8.0
1
24.0
0.27
0.18
Insect Screen (default)
Window 4
Window
Front Wall (Front-0)
4.0
5.0
2
40.0
0.34
0.24
Insect Screen (default)
Window 5
Window
Left Wall (Left-90)
----
----
1
26.0
0.30
0.26
Insect Screen (default)
Window 6
Window
Left Wall (Left-90)
----
----
1
35.0•
0.34
0.24
Insect Screen (default)
French Door 2
Window
Left Wall (Left-90)
3.0
8.0
1
24.0
0.27
0.18
Insect Screen (default)
Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance ReportVersion - CF1R-10172014-651 Report Generated at: 2014-11-04 20:25:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1M.xml
CF1 R-PRF-01
Page 5 of 9
OVERHANGS AND FINS -
01
02
03
04-
05
06
07
08
09
10
11
12'•
13
14
Overhang
Left Fin r
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up�
Dist R
Bot Up
Window 2
1.5
1.25
2
2
0
0
0
0
0
0
0
0
0
Door
10
0.1
10
10
1
0
0
0
0
0
0
0
0
French Door
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 4
5
0.1
6
6
0
0
0
0
0.
0
0
0
0
French Door 2
10
0.1
10
10
1
0
0
0 .. •
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01,
02
• 03
04
OS
06
Construction Name
Surface Type ,
Construction Type"
' Framing
Total Cavity R-value
Assembly Layers
Cavity/Frame: no insul. /2x4 Top Chrd
*1R
'f
-+2x4ZTop Cy horclofK
Roof Truss @ 241- .
7,
Roof Deck: Wood Siding/sheathing/decking
Tile Gap: present'
Attic Roof Cons
Attic Roofs �
,
Wood Framed Ceilmg7}p.C,?�
r none" - -
•. Roofing: 10 PSF (RoofTile)
"� 4r ram`
l `
Inside Finish: Gypsum Board
R-38 Roof RB
�.
Ceilings (below attic) ,
Wood Framed Ceiling r
-" 2x4 @ 24 in. O.C.
R 38
Cavit /Frame: R-9.1 /2x4
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
R-13 Wall
Exterior Walls`
; "Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Cavity/Frame: R-13/2x4
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
'
Cavity /Frame: R-19 / 2x6 •
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C:
R 19
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/ Frame: R-13 / 2x4
Garage R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Exterior Finish: Wood Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Covered Slab
Plan 1M 2
2415
242
None
0.8
No
Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54
CA Building Energy Efficiency Standards - 2013 Residential Compliance . Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-04 20:25:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1 M.xml
CF1 R-PRF-01
Page 6 of 9
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Required
1207.5
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Tank Exterior
Tank Volume
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
(gal)
Efficiency
Input Rating
R-value
(Fraction)
DHW Heater 1
Neural Gas k.,,$mall
Storage
� 5.0
�0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATIC`N .t�q
01
�,02 Jjf \;
+'�_. ... %U3� „�
-- < s
05
06
07
Name
_r--,Pipe lnsulationi
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
N/A f
N/A
N/A
N/A
N/A
N/A
HVAC SYSTEMS
01
02
03
04
05
06
07
" Name
System Type
Heating System
Name Ducted
Cooling System
Name Ducted
Distribution
System
Fan System
Floor Area
Served
Res HVAC1
Other Heat/Cool
Heating Component 1
Yes
Cooling Component 1
Yes
Air Distribution
System 1
2415
HVAC - HEATING SYSTEMS
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 l Report Generated at: 2014-11-04 20:25:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
•Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1 M.xml -
CF1 R-PRF-01
Page 7 of 9
HVAC - COOLING SYSTEMS
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Coolin Com onent 1
g P
SplitAirCond - Split air conditioning
12;.5
15
No
NoCooling.
Component
system
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
•
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS• ' -
01
02
�t; 03
04
05,
06
07
08
Name "
A -
r TYpe0,-.
1!4L
Duct Leakag
.. At+ +!;
Insulation R
Supply Duct
' 4 ,
,
valuedtLocation
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in attic
Sealed and tested '"4
�6+r I
Attic' .�
"Attic
None
Air Distribution
u Ar°::
System 1-hers-list
_4�-` r.o-• 1 �+v�� :x �alv�-:.�" .•,r:.�-� �—'-•.f �' �-.a...-� kr� i�F a� �.v -
HVAC DISTRIBUTION - HERS VERIFICATION75 .
01
02
I; 03
04
0506
07
Duct Leakage
g r
''
Verified Duct Design
Low -leakage
Name
Verification •
Duct Leakage Target (%)
Verified Duct Location
Return Supply
Air Handler
Air Distribution System
1-hers-dist
Required
�
6.0
Not Re uired
q
Not Re uired
q
Not Re uired
q
---
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: • 2014-11-04 22:03:54
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-04 20:25:55
. -CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 M
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:23, Tue, Nov 04, 2014,
Input File Name: 13174UP1 M.xml
HVAC Fan 1-hers-fan Required 0.58
CF1 R-PRF-01
Page 8 of 9
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Name
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%a)
HERS Verification
DwellingUnit
61.65
0.25
Default
0
Required
Registration Number: 214-N0132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:25:55
CERTIFICATE OF. COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 M Calculation Date/Time: 20:23, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP1M.xml
CF1 R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATIONSTATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Rudy Sains
!'a
CG"`�✓�acsca
Company:
Signature Date:
Heritage Energy Group .
2014-11-04 21:50:55
Address:
CEA/HERS Certification Identification (If applicable):
470 Wald
City/State/Zip:
Phone:
Irvine, CA 92618
949 584 1052
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system,design features identified.on-this Certificate of,Compliance.are.consistent-with the information provided on other applicable compliance documents,
worksheets, calculations, plans ands ecifications submi` t d to the enfor ement agency ford app o al with this building permit application.
Responsible Designer Name: �� F �"' -�
Responsible Designer Signature: .
Alex Gonzales ,rt-''j'
Company: - - - ° '
Date Signed:
GHA Companies
2014-11-04 22 03:54
Address:
License:
30-875 Date Palm Drive �,+.
N/A
City/State/Zip:
Phone:
Cathedral City, CA 92234
(760) 969-1400
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 214-No132968A-000000000-0000 Registration Date/Time: 2014-11-04 22:03:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:25:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD; '
Project Name: Plan.1X . - Calculation Date/Time: 20:43, Tue, Nov 04,.2014,'
Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml
CFIR=PRF-01 -
Page 1 of.10
GENERAL INFORMATION--
'' 01
-Project Name
Plan 1X -
02
Calculation Description
Title 24 Analysis- a
03•
�- ° • - .Project Location
Darby Lane
04
A City
La Quinta
05
, Standards Version
Compliance 2014
06
- Zip code
07
Compliance Manager Version
BEMCmpMgr 2013-3.(651) +
08
Climate Zone
CZ15 •
09
Software Version
EnergyPro 6.3
10
Building Type
Single Family
11 r
Front Orientation (deg/Cardinal)
Cardinal
12.
4 Project Scope
Newly Constructed
13
Number of Dwelling Units
1 E .�
14
Total Cond. Floor Area (FT?)
2698 ; ;.
15
` ' t Number of Zones
1
•.16
t Slab Area (FT2)
2698
417 .
Number of Stories
1
-. 18
, Addition Cond. Floor Area
N/A jam."' ,
19
Natural Gas Available
Yes
20
,Addition Slab.Area (FT?)
N/A
21
y Glaiing Percentage (%)
17.1% r
COMPLIANCE RESULTS "�/M��I{p/y*j��' -1i ^^ (����� T ' 1 rj ' � _ .- }�1
ry/' f t w 3JJ1.�`7 ii'aity.L I! • , , t
`01
•
Buildin Com lies with Com uter Performance; M '� ' �'
,rd.
• 02
This building incorporates features that'require=fell testing'yand/or'venfiCaton by a certified HERS rates urde��t�he�upervision of a CEC-approved HERS provider. _
'•03
This building incorporates one or more Special}Featu�e"s shown below
- qV
- , ,. ± s ..: • ..v � ,,,,. :... s ,.. .� � .t Yy • w � •,. _� •� .•, a N- , « •.. ♦ `+
Registration Number: 214-No132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaiCERTS inc.
CA Building Energy. Efficiency Standards 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17;
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP1X.xml
CFI R-PRF-01
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.39
2.40
-1.01
-72.7%
Space Cooling
99.24
97.73
1.51
1.5%
IAQ Ventilation
1.07
1.07
0.00
0.0%
Water Heating
10.05
9.12
.0.93
9.3%
PV Credit
----
0.00'
0.00
--
North Facing Compliance Total
111.75
110.32
1.43
1.3%
Space Heating
1.39
2.50
-1.11
-79.9%
Space Cooling
99.24
93.63
5.61
5.7%
IAQ Ventilation
1.07
1.07
0.00
0.0%
Water Heating
10.05
9.12
0.93
9.3%
PV Credit
i
0.00
0.00
East Facing Compliance Total
` 111.75
106.32
5.43
4.9%
Space Heating 1 39 .
Space Cooling ;_" 99 24.
IAQ Ventilation 1.07, ',.,
2<92
96.98
i
1 07
-1.53
2.26
' 0.00
-110.1%
2.3%
wl
Water Heating ; _ /�L4 1:< L `710,05,.'
�7 �"
9,.12r ,:
0.93
0.0%
9.3%
�.a
PV Credit
..ti
-"
r
0:00
0.00
----
South Facing Compliance Total-
111.75
110.09
1.66
1.5%
Space Heating
1.39
2.37
-0.98
-70.5%
Space Cooling
99.24
91.09
8.15
8.2%
IAQ Ventilation
1.07
1.07
0.00
0.0%
Water Heating
10.05
9.12
0.93
9.3%
PV Credit
0.00
0.00
----
West Facing Compliance Total
111.75
103.65
8.10
7.2%
Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014
'Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
CF1 R-PRF-01-
Page 3of 10
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications: '
• Building, Envelope Air Leakage
• IAQ mechanical ventilation
Cooling System Verifications: • `
• Verified EER
• Verified SEER ,
• Refrigerant Charge
• Fan Efficacy Watts/CFM k - -
HVAC Distribution System Verifications:
Duct Sealing id ,
Domestic Hot Water System Verifications
• --None u w
�i:�.r.._V:- ;/rci! .�.Y::Y Y- a :c'�t_�.. e�•-i -�..f.v. 3-4 t.c.,. �•::�:.ry ,.s,r,-....
ENERGY DESIGN RATING
This is the sum of the annual .TDV energy consumption for energy use components'included'in the performance compliance approach,for tFie Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and compo en ni of regulated by Title 24tPart 6 (such as domestic appliances`and'consumer electronics) and accounting for the annual TDV energy offset by an
on site renewable energy system. ,u ,� - "' " ?, -- . 'f; _r, ' .- .' �. �iaE . w7•'=
•' ,r
"` Reference Energy Use
vi. `,.; Energy Design Ratirg'A, ;i± -:
Margin '
Percent Improvement
Total Energy (kTDV/f2)•
T.,
i�'ti• �,..
154.80-
`%' _i n '' rx- 153.37 ti::: -, a #� '„
1.43
o
0.9 /a
kF'
` includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01 •'
02
03
04
05
- 06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1X
2698
1
4
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling.
Height
Water Heating System 1
Water Heating System 2
Plan 1X 2
Conditioned
Res HVAC1
2698
10
DHW Sys 1
Registration Number: 214-1\10132969A-00o000000-0000 Registration Date/Time: 2014-11-0422:04:34
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-10172014-651
HERS Provider: CalCERTS inc.
Report Generated at: 2014-11-04 20:46:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis _ Input File Name: 13174UP1X.xml
CF1 R-PRF-01
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area(ft)
' Window Area (ft)
Tilt(deg)
Back Wall
Plan 1X 2
R-13 Wall
180
Back
305
78
90
Back Wall 2x6
Plan 1X 2
R-19 Wall
180
Back
195
96
90
Right Wall
Plan 1X 2
R-13 Wall
270
Right
720
135
90
Right Wall 2
Plan 1X 2
R-19 Wall
270
Right
100
0
90
Front Wall
Plan 1X 2
R-13 Wall
0
Front
90
20
90
Left Wall
Plan 1X 2
R-13 Wall
90
Left
888
107.997
90
Front Wall -Garage
Plan 1X 2
Garage R-13 Wall
0
Front
208
0
90
Right Wall Garage
Plan 1X 2
Garage R-13 Wall
270
Right
29
0
90
Front Wall 2
Plan 1X 2 l
R-19 Wall
0
Front
200
25
90
Roof
Plan 1X 2
R-38 Roof RB
2698
ATTIC 77-
01
03,40T `f ¢
`"0f /
. % 04 w� 0;
_ _ , . 05
06
07
Name
> e Coristr`ucti6 i;k-
-Rise"
i Rdof Refflectence
frRooffrnittance
Radiant Barrier
Cool Roof
Attic
',Attid Roof Cons `
" 4 "F
" `` 0.1 "`
0.85
Yes
No
Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name:13174UP1X.xml
CF1 R-PRF-01
Page 5 of 10
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
Window
Window
Back Wall (Back-180)
----
--
1
18.0
0.34
0.24
Insect Screen (default)
Window 2
Window
Back Wall (Back-180)
12.0
5.0
1
60.0
0.30
0.26
Insect Screen (default)
Door
Window
Back Wall 2x6•(Back-180)
12.0
8.0
1
96.0
0.31
0.23
Insect Screen (default)
Window 3
Window
Right Wall (Right-270)
13.4
5.0
1
67.0
0.34
0.24
Insect Screen (default)
French Door
Window
Right Wall (Right-270)
3.0
8.0
1
24.0
0.27
0.18
Insect Screen (default)
Window 4
Window
Right Wall (Right-270)
4.0
5.0
1
20.0
0.34
0.24
Insect Screen (default)
French Door 2
Window
Right Wall (Right-270)
----
----
1
24.0
0.27
0.18
Insect Screen (default)
Window 5
Window
Front Wall (Front-0)
4.0
5.0
1
20.0
0.34
0.24
Insect Screen (default)
Window 6
Window
t Left Wall (Left-90)
----
----
1
26.0
0.30
0.26
Insect Screen (default)
Window 7
Window
4�Left Wall (Left-90)
11.8
5.0
0.983
58.0
0.34
0.24
Insect Screen (default)
French Door 3
Window
Left Wall (Left-90) ..�....
3.0
8.0
1
24.0
0.27
0.18
Insect Screen default
( )
Window 8
Window
_
` 1` ^ Fpnt,W!ll.2 (Front-0)
14.0_
r is S.Of
1.25
25.0
0.34
0.24
Insect Screen default
OVERHANGS AND FINS /tMe{fir..
01
,`02 '
'� ' 03 ; -
04
`. 05
06 T
07'
`' 08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
r
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window 2
1.5
1
3
3
0
0
0
0
0
0
0
0
0
Door
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 3
1.5
1
3
3
0
0
0
0
0
0
0
0
0
French Door
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 4
1.5
1
3
3
0
0
0
0
0
0
0
0
0
Window 5
5
0.1
6
6
0
0
0
0
0
0
0
0
0
Window 7
1.5
1
3
3
0
0
0
0
0
0
0
0
0
French Door 3
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 8
5
0.1
6
6
0
0
0
0
0
0
0
0
0
Registration Number: 214-N0132969A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2014-11-04 22:04:34
Report Version - CF1R-10172014-651
HERS Provider: CaiCERTS inc.
Report Generated at: 2014-11-04 20:46:17
• CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1X
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:43, Tue, Nov 04, 2014
Input File Name: 13174UP1X.xml
CF1 R-PRF-01
Page 6of10
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of
Roof Deck: Wood Siding/sheathing/decking
Roof Truss @ 24 in.
Tile Gap: present
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: 10 PSF (RoofTile)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-9.1 /2x4
R-38 Roof RB
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/ Frame: R- 13 / 2x4
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/Frame: R-19/2x6
R-19 Wall
Exterior Walls`.
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
Garage R-13 Wall
Exte iio-FW5lls
vWood,Framed>Wall .V
h
-1k2z41@X16°ui�Q:C''t
F M
Y R 13
Exterior Finish: Wood Siding/sheathing/deckin
g
r I i /, +
SLAB FLOORS f It m V " k �! w--," e7+St r�°t
01
'` 102 ` .
i Z 03
„ll..
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Covered Slab
Plan 1X 2;'
2698
282
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Required
1349.0
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1
1
.0%
Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1X Calculation Date/Time: 20:43, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml
CFI R-PRF-01
Page 7 of 10
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
N/A
N/A
N/A
N/A
N/A
N/A
HVAC SYSTEMS )
01
02
03
04
05
06
07
Heating System
Cooling System
Distribution
Floor Area
Name
ISyst" pe 7
Name 7'_ - Ducted
'_7 VyrNaImT"e Ducted
System
Fan System
Served
Res HVAC1
4 �
j r
JOther HeaUCool . ;
Heating Component 1� Yes
` �*
Cooling•Component 1 Yes
Air Distribution
2698
.1 . Nr pry. / it fit;
System 1
HVAC - HEATING SYSTEMS
01 r'
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING SYSTEMS
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
12.5
7 15
No
No
Cooling Component
system
1-hers-cool
Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17
CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1X - Calculation Date/Time: 20:43, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml
CFI R-PRF-01
Page 8 of 10
HVAC COOLING -HERS VERIFICATION
'
01 02
03 04 05 06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified RefrigerantCharge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07.
08
Name `
Type
Duct Leakage
Insulation R-value
Supply Duct
Location
Return Duct
Bypass Duct -
HERS Verification
Air, Distribution System 1
Ducts located in attic
Sealed and tested
6 -
Attic
•
Attic
None
Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION +
01
� 02
'+ 03
04
05
06
07
Duct L-eakage
r
Verified Duct Design
Low -leakage
Name
Verification ~
? ; Duct Leakage Target (%) Tia.
Verified -Duct Location_
Return Supply
Air Handler
Air Distribution System
+ ,
1-hers-dist
dr IRe uire
6 0 zf�r...
•�-.,:
Not Required
Not Required
/,.r�
HVAC-FAN SYSTEMS -+
01
02
03
04'
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency
y (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
IAQ Recovery
Name IAQ CFM IAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification
DwellingUnit 64.48 0.25 Default . .0 Required
Registration Number: 214-No132969A-000000000-Q0o0 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: CaiCERTS inc.
�CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Plan 1X 1, Calculation Date/Time: 20:43, Tue, Nov 04, 2014 Page 9 of 10
Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xm1
` r °'. > � �� .. !i gw�� y9 "-., � if�wy z"r'*� 3 � ,,,y �� '� � .��''s"� h . • — � a � • _
( "p $ �� '"'�P .� t:��y�CTT�, t �+f fe i.` R•�. y ,•,.hcr. •'^r(�.
.. � , f J ' � • � 4fyy . -' "9'" •y�.. �+�' � 4 £- , z�- t�-•���'N'"_n y�,C, _ a f y'• i'. r r-,sj fir - - '• ., � r ♦ , .
• � sue, �•-';,y e.*3 :, ,i .- !
.. , t.. ) • _ � ' fit{ +.f • • } a - '
Registration Number: 214-N0132969A-000000000-0000 Registration. Date/Time: 2014-11-04 22:04:34 - HERS Provider: CaICERTS inc. '
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version CF1R 10172014-651 Report Generated at: 2014-11-04 20:46:17
CERTIFICATE OF COMPLIANCE: RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1X Calculation DatelTime: 20:43, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP1X.xml
r
CF1R-PRF-01'.
Page 10 of 10
DOCUMENTATION. AUTHOR'S DECLARATION STATEMENT ;.
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Rudy Sains-
Company:
Signature Date:
Heritage Energy Group
2014-11-04 21:52:49
Address:
CEA/HERS Certification Identification (If applicable):
470 Wald
City/State/Zip:
Phone:
Irvine, CA92618 _ �.
949 584 1052 ,
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
•.1. _ 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. '
2. 1 certify that the energy featuies and performance specifcations identified on this Certificate of Compliance conform to the requirements Title 24, Part 1 Part 6 the California Code "
of and of of
Regulations.
'The
3. building design features or system design features identified on this Certificate of Compliance.: are. consistent -with the information rovided on other a licable com liance documents,
it,
worksheets, calculations, plans an clspe_cifications submitted to<the enforcement a e approval with this building permit application. '
pcy;for
Res onsible Designer Name:
P 9
RR6ssp6Hsible Designn6ir Signature .- �+
Alex Gonzales '> ..`_
�Peai�asteaeea
Company:s.�
Date Signed' .. -
n
GHA Companies ,.��„
2014-11-04 22:04':34.
Address: t
ice
L 'n se:.
^� 30-875 Date Palm Drive
N/A' • ' `
City/State/Zip:
Phone:
Cathedral City, CA 92234
(760) 969-1400 .
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information. ,
Registration Number: 214-N0132969A-000000000-0000 Registration Date/Time: 2014-11-04 22:04:34 HERS Provider: ` CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance ,Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:46:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml
CF1 R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Plan 2
02
Calculation Description
Title 24 Analysis
03
Project Location
'Darby Lane
04
A City
La Quinta
05
Standards Version
Compliance 2014
06
Zip code
07
Compliance Manager Version
BEMCmpMgr 2013-3 (651)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.3
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
2709
15
Number of Zones
1
16
Slab Area (FT2)
1418 .
17
Number of Stories
2
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
Yes
20
Addition Slab Area (FT2.)
N/A
21
Glazing Percentage (%)
17.0%
COMPLIANCE RESULTS
01
Building Complies with Com uter Performances'
02
This building incorporates features thafyrequire' field testing and/or venfication by a certified HERS`rater under',the�supervision of a CEC-approved HERS provider.
03
This building incorporates one or mope Sliecial features shown below
N
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R'-PRF-01
Project Name: Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Input File Name: 13174UP2.xml
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ftz-yr)
Design
Design
Margin
Improvement
Space Heating
1.77 2.73
-0.96
-54.2%
Space Cooling
98.93 94.92
4.01
4.1%
IAQ Ventilation
1.19 1.19
0.00
0.0%
Water Heating
10.01 9.09
0.92
9.2%
PV Credit
---- 0.00
0.00
----
North Facing Compliance Total
111.90 107.93
3.97
3.5%
Space Heating
1.77 2.88
-1.11
-62.7%
Space Cooling
98.93 98.00
0.93
0.9%
IAQ Ventilation
1.19 1.19
0.00
0.0%
Water Heating
101.01 9.09
0.92
9.2%
PV Credit
0.00
0.00
East Facing Compliance Total .
111.90 111.16
0.74
0.7%
Space Heating 1:77 120
Space Cooling - < 98.93 94:91
P 9
IAQ Ventilation +-- € 1.19 t 1y;19�,=
-1.43
4.02
0.00
-80.8%
4.1%
0.0%
Water Heating }fi
Y#
10.01 = �,
0.92
9.2%
PV Credit
A9
0.00
w111.90
0.00
---
South Facing Compliance•Total"�
108.39
3.51
3.1%
Space Heating ":
1.77 2.99
-1.22
-68.9%
Space Cooling
98.93 94.71
4.22
4.3%
IAQ Ventilation
1.19 1.19
0.00
0.0%
Water Heating
10.01 9.09
0.92
9.2%
PV Credit
--- 0.00
0.00
----
West Facing Compliance Total
111.90 107.98
3.92
3.5%
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins ,
CF1R-PRF-01 '
Page 3 of 10
HERS FEATURE SUMMARY f
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• Building Envelope Air Leakage
• IAQ mechanical ventilation
.Cooling System Verifications_:
• Verified EER
• Verified SEER
•; Refrigerant Charge -
• Fan Efficacy Watts/CFM'
HVAC Distribution System Verifications:. -
• .Duct Sealing
Domestic Hot Water System Verifications:"
-- None
ENERGY DESIGN RATING 4,.rz1
dam' syr If i,n -
T `
This is the sum of the annual TDV energy onsumptio forr energyuse components included i the performance c pliance app�roR �h5forethe Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and compo'n`ents not.regulated bymTitle 24, Part-6 (such as domesbcappliancesTand consumerelectronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system. - ,... �r < .," "' rs':r« ., , w-..,-•s
4�;""n•
"`,y Reference Energy Use '3
Energy Design Rating X ;)
Margin
Percent Improvement
Total Energy (kTDV/f2)'
155.04"-}154
30
0.74
0.5%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
(
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2
2709
1
5
1
0
1
ZONE INFORMATION s
01:
02
-03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Plan 2 2
Conditioned
Res HVAC1
2709
10
DHW Sys 1
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 - Report Generated at: 2014-11-04 20:20:30
4
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml
Y
CFI R-PRF-01
Page 4 of 10
OPAQUE SURFACES
01
02
03
04
05.
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tilt(deg).
Back Wall
Plan 2 2
R-13 Wall
180
Back
560
125
90
Back Wall 2
Plan 2 2
R-19 Wall
180
Back
240
126
90
Right Wall
Plan 2 2
R-13 Wall
270
Right
648
61
90
Right Wall 2
Plan 2 2
R-19 Wall
270
Right
100
0
90
Front Wall
Plan 2 2
R-13 Wall
0
Front
564
64
90
Left Wall
Plan 2 2
R-13 Wall
90
Left
783
83.5
90
Front Wall -Garage
Plan 2 2
Garage R-13 Wall
0
Front
80
0
90
Right Wall Garage
Plan 2 2
Garage R-13 Wall
270
Right
64
0
90
Front Wall-Garage6
Plan 2 2,
R-19 Wall
0
Front
154
0
90
Roof
Plan 2 2
R-38 Roof RB
1738
Raised Floor
Plan 2 2
R-19 Floor Crawlspace
320
ATTIC
`//1`
01
.�/02_0?iFa•!`V.+.
Il'.a 03i F
�04: 'a.:IIItr,W.U5
06
07
Name
'11°Construction ,. J
w,Roof Rise
Roof Reflectance'
Roof Emittance
Radiant Barrier
Cool Roof
Attic
-.--.--^Attic"Roof Cons_
4
0.1
0.85
Yes
No
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-'04 22:05:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml
CF1 R-PRF-01
Page 5 of 10
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
_
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
Window.
Window
Back Wall (Back-180)
----
-
1
9.0
0.34
0.24
Insect Screen (default)
Window 2
Window
Back Wall (Back-180)
----
-
1
30.0
0.30
0.26
Insect Screen (default)
Window 3
Window
Back Wall (Back-180)
----
----
1
86.0
0.34
0.24
Insect Screen (default)
SGD
Window
Back Wall 2 (Back-180)
12.0
8.0
0.5
48.0
0.31
0.23
Insect Screen (default)
Window 4
Window
Back Wall 2 (Back-180)
12.0
5.0
1
60.0
0.30
0.26
Insect Screen (default)
Window 5
Window
Back Wall 2 (Back-180)
12.0
1.5
1
18.0
0.34
0.24
Insect Screen (default)
Window 6
Window
Right Wall (Right-270)
----
----
1
28.0
0.34
0.24
Insect Screen (default)
Window 7
Window
Right Wall (Right-270)
6.6
5.0
1
33.0
0.34
0.24
Insect Screen (default)
Window 8
Window
(Front Wall (Front-0)
12.2
5.0
1
61.0
0.34
0.24
Insect Screen (default)
Window 9
Window.
Front Wall (Front-0)
----
----
1
3.0
0.30
0.26
Insect Screen (default)
Window 10
Window
Left Wa11 (L9W)
M
1
33.5
0.30
0.26
Insect Screen (default)
Window 11
Window
d
IX" 1'` Left'Wall Left-90 ,- � , '
r jp , _ ( F) . � .' ".� '
�8.0 k
�- 5.l)
1.25
50.0 1
0.34
0.24
Insect Screen (default)
OVERHANGS AND FINS k .�# { 1: '' �...� F .` T .4avF,
01
' 62'
�_103
'- 64 `
_ 057". 717,
7 06-
07
- 08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
�-
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
SGD
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 4
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 5
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 7
1.5
1
3
3
0
0
0
0
0
0
0
0
0
Window 8
1
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 11
1.5
1
3
3
0
0
0
0
0
0
0
0
0
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Plan 2
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Input File Name: 13174UP2.xml
Page 6 of 10
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of
Roof Deck: Wood Siding/sheathing/decking
Roof Truss @ 24 in.
Tile Gap: present
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofing: 10 PSF (RoofTile)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-9.1 / 2x4
R-38 Roof RB
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R- 13 / 2x4
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/Frame: R-19/2x6
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
Garage R-13 Wall
Exteri6FW51ls
T7Wood'FFaMed-Wall-r,7
-2z4-@\16!inYO-C--S
j R 13
Exterior Finish: Wood Siding/sheathing/decking
F
1+
Floor Surface: Carpeted
•gFloor Deck: Wood Siding/sheathing/decking
R-19 Floor Crawlspace
Floors'IOJer C {awlsp
Wood Frame/Flo ,/'@
24 ir�O.0
RA19� I
Cavity/Frame: R-19 /2x8
SLAB FLOORS ..--
01
02
03
04
05
06
07
Name
Zorie. ;
Area (ft)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Covered Slab
Plan 2 2 -
1418
152
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Required
1354.5
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1
1
.0%
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis' Input File Name: 13174UP2.xml
CF1 R-PRF-01
Page 7 of 10
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R_-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
N/A
N/A
N/A
N/A
N/A
N/A
HVAC SYSTEMS
01
02
03
04
05
06
07
Heating System
Cooling System
Distribution
Floor Area
Name
Sy Ist pe
Name x _ '`, Ded uct
Name Ducted
System
Fan System
Served
Res HVAC1
r+
Other HeaUCool /j.
#
o '-� `
Heating Component 1 {
? [Yes /f
n , t+
'Cooling Gompon,ent 1
`
Yes
Air Distribution
2709
it ,4 _'
t ;�
w s"'.
y ..�,J
..a-.-4. 'lll�
did'
System 1
Y
HVAC -HEATING SYSTEMS
01 , -
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING SYSTEMS
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification.
Cooling Component 1
SplitAirCond - Split air conditioning
12.5
15
No
No
Cooling Component
system
1-hers-cool
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP2.xml
CF1 R-PRF-01
Page 8 of 10
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Name
Type
Duct Leakage
Insulation R-value
Supply Duct
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in attic
Sealed and tested
6
Attic
Attic
None
Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION �.
01
02
03
04
05
06
07
Name
Duct Leakage'
Verification
TargeT4, '
Verified Duct Design
Low -leakage
j )Jf��('fJ Duct Leakage r
Verified -Duct. Location
Return Supply
Air Handler
Air Distribution System
dist
Required f
6r--k
.01-hers
roj:R,e Zuired .
Not Required
Not Required^
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Name
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
DwellingUnit
72.09
0.25
Default
0
Required
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 Calculation Date/Time: 20:18, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP2.xml
r
7,77,77
otj
Registration Number: 214-NO132970A-000000000-0000 Registration Date/Time: 2014-11-04 22:05:41
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
CF1R,-PRF-01
Page 9 of 10
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 Calculation Date/Time: 20:18, Tue,`Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP2.xml
- 1
CF1 R-PRF-01
Page 10 of 10
DOCUMENTATION: AUTHOR'S DECLARATION STATEMENT •' - �,
1. 1 certify that this, Certificate of Compliance documentation is accurate and complete:
Documentation Author Name:
Documentation Author Signature:
Rudy Sains
Company:
Signature Date:
Heritage Energy Group . , -
2014-11-04 2.1:54:52 ,
Address:
CEA/HERS Certification Identification (If applicable): .,
470 Wald
City/State/Zip:
Phone:
Irvine, CA 92618
949 584 1052•
RESPONSIBLE PERSON'S DECLARATION STATEMENT 3
I certify the following under penalty of perjury, under the IavJsof•the State of California:
1.. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. c
2.: I certify that the energy features and pe;rformance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part land Part 6 of the California Code of
Regulations.'t
3. The building design features or:system.design features dentifieed--oon-this Certificate of Compliance.arexonsistent-with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specification submitted to�the enfor agency f ppr a w t hi buihding
cement permit application.
Responsible Designer Name:
w •k t�',. '�,'� may. #` �r
F4
Responsible Designer Signature -
�*'.•^r - ..�•
Q1W
Alex Gonzales ! �- t�
i.. .
>..
r . ,
_.-_:=
Company:y Mz
N
Date Signed: ,.= a
GHA Companies
2014-11-04 22:05:41 i
Address:' f
License:
30-875 Date Palm Drive •
N/A
City/State/Zip:
Cathedral City, CA 92234
rPhone:
60) 969-1400
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for theaccuracy of the
information.
y
Registration Number: 214-NO13297OA-000000000-0000 Registration Date/Time: 2014'11-04 22:05:41 HERS Provider: - CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CFiR-10172014-651 Report Generated at: 2014-11-04 20:20:30
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01'
Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014 Page 1 of 9
Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml !'
GENERAL INFORMATION -
01
Project Name
Plan 2X
02
Calculation Description
Title 24 Analysis
03
Project Location
Darby Lane
04
A City
La Quinta
05''
Standards Version
Compliance 2014
06
Zip code
07
Compliance Manager Version
BEMCmpMgr 2013-3 (651)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.3 t
-10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
- Total Cond. Floor Area (FT2)
2709
15
Number of Zones
1
16
Slab Area (FT2)
1418
17
Number of Stories
2 -
18
Addition Cond. Floor Area
N/A�, ,
19
Natural Gas Available
Yes "
20
Addition Slab Area (FT?)
.;
N/A f'
."21
• Glazing Percentage (%)
16.6%
COMPLIANCE RESULTSJ1.0C Yw
01
Building Complies with Computer Performance}`•��4
� f,'..�,..�,-�,•-lei;� �:•,.�.s:�r� i6FY�r1���c'� !•�„�--„-•�� �rwt•:.r� Gtt:`
" 02
This building incorporates`;features that 'regwre field testing"yand/oQenfication by a certified HERSlratet urid(5ti44s vision of a CEC-approved HERS provider.
- -
03
This building incorporates one'or more `Speciali eatures shown below '' "' t
' f
Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 - Report Generated at: 2014-11-04 20:51:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis
Input File Name: 13174UP2X.xml
CF1 R-PRF-01
Page 2 of 9
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.77
2.89
-1.12
-63.3%
Space Cooling
98.31
94.60
3.71
3.8%
IAQ Ventilation
1.19
1.19
0.00
0.0%
Water Heating
10.01
9.09
0.92
9.2%
PV Credit
----
0.00
0.00
----
North Facing Compliance Total
111.28
107.77
3.51
3.2%
Space Heating
1.77
2.95
-1.18
-66.7%
Space Cooling
98.31
97.27
1.04
1.1
IAQ Ventilation
1.19
1.19
0.00
0.0%.
Water Heating
10.01
9.09
0.92
9.2%
PV Credit
�: `.
----
0.00
0.00
----
East Facing Compliance Total
111.28
110.50
0.78
0.7%
Space Heating 1:77 3:25�. -1.48
Space Cooling 8 31 94.92 � 3.39
IAQ Ventilation 1 - 1.19 0.00
-83.6%
3.4%
0.0%
Water Heating%•
10r01
_ .. �. '.�
�a'{ C-P
0.92
9.2%
PV Credit
- --
.. 0:00
0.00
---
South Facing Compliance -Total'
111.28
108.45
2.83'
2.5%
Space Heating
1
1.77
3.06
-1.29
-72.9%
Space Cooling
\
98.31
94.19
4.12
4.2%
IAQ Ventilation
1.19
1.19
0.00'
0.0%
Water Heating
10.01
9.09
0.92
9.2%
PV Credit
--
0.00
0.00
----
West Facing Compliance Total
111.28
107.53
3.75
3.4%
J
Registration Number: 214-No132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:51:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
CF1 R-PRF-01,
Page 3 of 9
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
'
Building -level Verifications:
• Building Envelope Air Leakage
• IAQ mechanical ventilation
Cooling System Verifications:
_
• Verified EER
r
• Verified SEER
• Refrigerant Charge
'
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
`
• Duct Sealing. . •...
1.
Domestic Hot Water System Verifications:
;
• --None - :�
i•
V 4,. Y x..air,f�.,•....4.3=rgYr-�.�.:r��r.W.:.rr.,.
ENERGY DESIGN RATING`
psi 3r.. • ,. 4
..v8 A .1'.. -' _.._.,.--
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliahce approach for the Standard Design Building (Energy Budget) and the annual '
TDV energy consumption for lighting and components not-regulated�by Title 24, Part 6 (such as domestic appliances an`d consume�.6 ec`tronics) and accounting for the annual TDV energy offset liy an
� T s ��' •s 'lr. T .� ..,.+> ::;fif: ,�
.tom E4 c rill
on -site renewable energy system.i -
-
Reference Energy Use
Energy Design Rating•'. _„ "VC=
Margin
Percent Improvement
Total Energy (kTDV/f2)*
'ti j� 154.42
°-a: r. , „ 153 64 - t
0.78
0.5%
* includes calculated Appliances and.Miscellaneous Energy Use'(AMEU)
BUILDING - FEATURES INFORMATION
01
02.
0S.
04
05
06 -
07-
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2X .
2709
1
5
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07'
Zone Name '
ZonerType
HVAC System Name
Zone Floor Area
(ft)
- Avg. Ceiling
Height
Water Heating System 1.
Water Heating System 2
•Plan 2X 2
Conditioned
Res HVAC1
2709
10
DHW Sys 1
Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-04 20:51:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2X
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:49, Tue, Nov 04, 2014
Input File Name: 13174UP2X.xml
CFI R-PRF-01
Page 4 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window Area (ft)
Tilt(deg)
Back Wall
Plan 2X 2
R-13 Wall
180
Back
800
240.5
90
Right Wall
Plan 2X 2
R-13 Wall
270
Right
648
61
90
Right Wall 2
Plan 2X 2
R-19 Wall
270
Right
100
0
90
Front Wall
Plan 2X 2
R-13 Wall
0
Front
564
64
90
Left Wall
Plan 2X 2
R-13 Wall
90
Left
783
83.5
90
Front Wall -Garage
Plan 2X 2
Garage R-13 Wall
0
Front
80
0
90
Right Wall Garage
Plan 2X 2
Garage R-13 Wall
270
Right
64
0
90
Front Wall-Garage6
Plan 2X 2
R-19 Wall
0
Front
154
0
90
Roof
Plan 2X 2 `t
R-38 Roof RB
1738
Raised Floor
Plan 2X 2
R-19 Floor Crawlspace
320
ATTIC /r Y /� A,. .__V i.
01
� i
0.7
0Y
04 t., ... 0
_05
06
07
Name
Constr'uctionjtf k• =;/
Roof..Rise" _'
"`Roof Reflectance,rf
FjRoof Emittance
Radiant Barrier
Cool Roof
Attic
' Attic Roof Cons -
=' 4
0.1
0.85
Yes
No
WINDOWS
01
02
t 03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
Window
Window
Back Wall (Back-180)
----
----
1
13.5
0.34
0.24
Insect Screen (default)
Window 2
Window
Back Wall (Back-180)
9.0
5.0
1
45.0
0.30
0.26
Insect Screen (default)
SGD
Window
Back Wall (Back-180)
12.0
8.0
1
96.0
0.31
0.23
Insect Screen (default)
Window 3
Window
Back Wall (Back-180)
----
----
1
86.0
0.34
0.24
Insect Screen (default)
Window 4
Window
Right Wall (Right-270)
----
----
1
28.0
0.34
0.24
Insect Screen (default)
Window 5
Window
Right Wall (Right-270)
6.6
5.0
1
33.0
0.34
0.24
Insect Screen (default)
Window 6
Window
Front Wall (Front-0)
12.2
5.0
1
61.0
0.34
0.24
Insect Screen (default)
Window 7
Window
Front Wall (Front-0)
----
1
3.0
0.30
0.26
Insect Screen (default)
Window 8
Window
Left Wall (Left-90)
-
1
33.5
0.30
0.26
Insect Screen (default)
Window 9
Window
Left Wall (Left-90)
8.0
5.0
1.25
50.0
0.34
0.24 1
Insect Screen (default)
Registration Number: 214-No132971A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2014-11-04 22:06:44
Report Version - CF1R-10172014-651
HERS Provider: CaICERTS inc.
Report Generated at: 2014-11-04 20:51:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Plan 2X
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:49, Tue, Nov 04, 2014
Input File Name: 13174UP2X.xml
Page 5 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
Window 2
10
0.1
10
10
1
0
0
0
0
0
0
0
0
SGD
10
0.1
10
10
1
0
0
0
0
0
0
0
0
Window 5
1.5
1
3
3
0
0
0
0
0
0
0
0
0
Window 6
1
0.1
2
2
0
0
0
0
0
0
0
0
0
Window 9
1.5
1
3
3
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
r
��.
f
" +1 \ -
)2x4 Top Chord of
Roof russ @�24 in.
7
p -
Cavity/Frame: no insul. /2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Tile Gap: present
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
none
Roofin 10 PS RoofTile
�'':r`Cy C- '
':. `c.i, d°"'t- `` =
- �+'-K�.a`- '. f..
1�1/s
• Inside Finish: Gypsum Board
• Cavity / Frame: R-9.1 / 2x4
R-38 Roof RB
Ceilings-(below.attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
R-13 Wall
Exterior Walls
+ Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/Frame: R-19/2x6
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity / Frame: R-13 / 2x4
Garage R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Exterior Finish: Wood Siding/sheathing/decking
• Floor Surface: Carpeted
• Floor Deck: Wood Siding/sheathing/decking
R-19 Floor Crawlspace
Floors Over Crawlspace
Wood Framed Floor
2x8 @ 24 in. O.C.
R 19
Cavity/Frame: R-19/2x8
Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:51:33
. r
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2X _ Calculation Date/Time: 20:49, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml
CFI R-PRF-01
Page 6 of 9
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated ,
Covered Slab
Plan 2X 2
1418
152
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Required
1354.5
WATER HEATING SYSTEMS ,
01
02 i_
03
04
05
06
Name
System Type,.*'
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0%
WATER HEATERS
Ir����*F,r:.�.e
01
� ` 02 �1`tF''
)t +fin 03
►i�"' .04 J. ai
05 , '
•�06'
07
08
Name
Heater Element Type
F Tank Type
A 3r-
Tank`Volume.
+ �t� 59
Energy Factoror -
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
- ^"TNatural Gas f.
j` Small Storage
50
0:62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys`1 - 1/1
N/A
N/A
N/A
• N/A
N/A
N/A ' `
HVAC SYSTEMS '
01
02
03
04
05
06
07
Name
System Type
Heating System
Name Ducted
Cooling System
Name: Ducted
Distribution
System
Fan System
Floor Area
Served
Res HVAC1
Other Heat/Cool
Heating Component 1T
Yes
Cooling Component 1
Yes
Air Distribution
System 1
2709
Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651
HERS Provider:' - CaICERTS inc.
Report Generated at: 2014-11-04 20:51:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2X Calculation DatetTime: 20:49, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis F Input File Name: 13174UP2X.xml
-r
CF1 R-PRF-01
Page 7 of 9
HVAC.-HEATING SYSTEMS �•
01
02
03
Name
? Type
f Efficiency
' Heating Component 1,
CntrlFurnace - Fuel -fired central furnace'
80 AFUE r
HVAC - COOLING SYSTEMS
01
02
03
04 ''
05
06 •
07
Efficiency
f
Multi -speed
Name :
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
r
SplitAirCond - Splitcond
- itioning' ditioning'
'
12.5
; '
15
No
No,
Conlin
_ 9 Component
.
system -
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02 :: ..
-
03
04
05
06'
Name
y
Verified Airflow =.r.+rrw...•
Airflow Target
.r> : w
Verified EER
y.v.•,.+► 4�
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool�Te*350`�`,
Required
Required
Required
HVAC -:DISTRIBUTION SYSTEMS �"
�' f"5e+"'}'`�fj
_"•`
�x 01 -
-02f'o.
a 03hrbv�s�
04r"r
"s+';05
06
07
08
Name
Supply Duct
;Type
a Duct Leakage
Insulatiori R-value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in attic ''
Sealed and tested
6
Attic
Attic
None
Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
" Name
Duct Leakage
Verification
Duct Leakage Target (%)
Verified Duct Location
Verified Duct Design
Return Supply"
Low -leakage
Air Handler
Air Distribution System
' 1-hers-dirt•
Required
6.0
Not Required
Not Re uired
Not Required
---
{. Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: ° ` 2014-11-04 22:06:44
CA Building Energy Efficiency Standards - 2013 Residential Compliance w Report Version - CF1R-10172014-651
HERS Provider: ' CaICERTS inc.
Report Generated at: 2014-11-04 20:51:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml
CFI R-PRF-01
Page 8 of 9
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04 1
05
06
Name
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
DwellingUnit
72.09
0.25
Default
0
Required
Registration Number: 214-No132971A-000000000-0000 Registration Date/Time: 2014-11-0422:06:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-04 20:51:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2X Calculation Date/Time: 20:49, Tue, Nov 04, 2014
Calculation Description: Title 24 Analysis Input File Name: 13174UP2X.xml
CF1 R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Rudy Sains
Company:
Signature Date:
Heritage Energy Group
2014-11-04 21:57:19
Address:
CEA/HERS Certification Identification (If applicable):
470 Wald
City/State/Zip:
Phone:
Irvine, CA 92618
949 584 1052
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. 1
3. The building design features or system -design features identified •on.this Certificate of Compliance.are.consistent-with the information provided on other applicable compliance documents,
worksheets, calculations, plans and 'specifications subm ed-t to he a for ement age cy foru approval with this buihdhg permit application, pp p
Responsible Designer Name: t
Responsible Designer Signature:_'
Alex Gonzales
�Pe�ri�a�c¢aeea-
Company:
Date�Signed:-
GHA Companies -�
2014-11-04 22:06:44
Address:
License:
30-875 Date Palm Drive h`�t.
!
N/A
City/State/Zip:
Phone:
Cathedral City, CA 92234
(760) 969-1400
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 214-N0132971A-000000000-0000 Registration Date/Time: 2014-11-04 22:06:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-10172014-651 Report Generated at: 2014-11-04 20:51:33
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Plan 1
Date
11/5/2014
System Name
Res HVAC
Floor Area
2,359
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
. COIL
CFM
Total Room Loads 1,264
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
,
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
25.584
2,t35
- 782
-
28,361
Total Output Btuh
89.000
0
Output Btuh/s tt
37.7
1,746
1,636
Cooling System
0
0
Output per System
46,500
0
0 0
0
Total Output Btuh
46,500
0
.
2,135
0
Total Output(Tons)
3.9
1,746
1,636
Total Output Btuh/s ft
19.7
Total output s ttrron
606.E
1 29,076
31.632
Air System
CFM per System
1.680
HVAC EQUIPMENT SELECTION
Airflow cfm
1,680
15/12/80%
31.981
7,489.
89,000
Airflow cfm/s ft
0.71
Airflow cfm/Ton
433.5
Outside Air %
0.0 %
Total Adjusted System Output 31,981
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
7,489 89,000
Aug.3 PM I Jan 1 AM
Outside Air cfm/s tt
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating,Peak
26 IF '69 IF
Outside Air O
O'cfm Supply Fan
1,680 cfm
69 OF
69 OF 105 IF
Heating Coil
t
'
104 IF
ROOM a
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112178 IF 76 / 62 IF 76 / 62 OF 55 / 54 °F
=='
Outside Air c�,
0 cfm Supply Fan Cooling Coil 56 / 54 IF
1,680 cfm
47.5 % ( ROOM
76162 IF 75 / 62 OF
I
EnergyPro 6.3 by EnergySoff User Number: 7244 RunCode: 2014-11-05T10:06:10 ID: 13174U
Page 1 of 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Plan 1 M
Date
11/5/2014
System Name
Res HVAC
Floor Area
2,415
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,252
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Out ut erSystem
89,000
25,364
2,186
770
27.943
Total Output Btuh
89.000
0
Output Btuhfs ft
36.9
1.731
1,612
Cooling System
0
0
Output perSystem
46.500
01
0 0
0
Total Ou ut Btuh
46.500
01
2,186
0
Total Output(Tons)
3.9
1,731
1,612
Total Output Btuh/s ri
19.3
Total Output s riITon
623.2
1 28,826
31,167
Air System
CFM per System
1,680
HVAC EQUIPMENT SELECTION
Airflow cfm
1,680
15/12/80%
31,955
7,521
89,000
Airflow cfm/s ri
0.70
Airflow cfmfTon
433.5
Outside Air /
0.0 %
Total Adjusted System Output 31,955
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
7.521 89,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s tt
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 IF 69 IF
0'
Outside Air
0 cfm Supply Fan
1,680 cfm
69 OF
69 IF 105 OF
Heating Coil
104 IF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Tem eratures at Time of Cooling Peak
112/78IF 76/62OF 76/62IF 55/54IF
Outside Air c
0 cfm Supply Fan Cooling Coil 56 / 54 IF
1,680 cfm
47.5 i ( ROOM
76/62OF 75162IF
EnergyPro 6.3 by Energ SoR User Number. 7244 RunCode: 2014-11-05T10:06:36 ID: 13174U
Page 1 of 1 -
M
±
7
J
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Plan 1X
Date
11/5/2014
System Name
Res HVAC
Floor Area
2,698
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,453
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
-
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
29,196
2,442
871
31,484
Total Output Btuh
89,000
0
Output Btuh/s ft
•33.0
1,992
1,816
Cooling System
0
0
Output per System
46,500
0
01 0
0
Total Output Btuh
46,500
0
2.442
0
Total Output(Tons)
3.9
1,992
1,816
Total Output Btuh/s tt
17.2
Total Output s f rron
696.3
1 33.1811
35,116
Air System
CFM per System
1,680
HVAC EQUIPMENT SELECTION.
Airflow cfm
1,680
15/12/80%
32,048
7.488
-89,000
Airflow cfm/s ft
0.62
Airflow cfm[Ton
433.5
Outside Air /
0.0 %
Total Adjusted System Output 32,048
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
7,488 89,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 IF 69 IF
Outside Air
0 cfm Supply Fan'
1,680 cfm
69 IF
69 IF 105 OF
'
Heating Coil
-
104 IF
ROOM
70 IF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 IF 76 / 62 IF 76 l 62 OF 55 / 54 OF
As 0' c
Outside Air
0 cfm Supply Fan Cooling Coil 56 / 54 IF
1,680 cfm .
47.7 % ( ROOM
76162°F 75/62°F
EnergyPro 6.36 EnergySoR User Number 7244 RunCode: 2014-11-05T10:09:06 ID: 13174U
Page 1 o/ 1
r
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Plan 2
Date
11/5/2014
System Name
Res HVAC
Floor Area
2,709
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,468
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
.89,000
29,799
_ 2,866
829
-
30,203
Total Output Btuh
89.000
0
Output(Btu h/s tt
32.9
1,649
1,340
Cooling System
0
0
Output perS stem
46,500
0
0 0
0
Total Output Btuh
46,500
0
2,866
0
Total Out ut(Tons)
3.9
1,649
1,340
Total Output Btuh/s tt
17.2
Total Output s ft/Ton
699.1
1 33,0981
32,884
Air System
CFM perSystem
1,680
HVAC EQUIPMENT SELECTION
Airflow cfm
1.680
15/12/80%
31.684
7,875
89,000
Airflow cfm/s ff
0.62
Airflow cfm/Ton
433.5
Outside Air %
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
' TIME OF SYSTEM PEAK
31,684
7,875 89,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s tt
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 IF 69 IF
Outside Air
0 cfm Supply Fan
1,680 cfm
69 IF
69 IF 105 IF
Heating Coil
104 IF
ROOM
70 IF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 ! 78. OF 76 / 62 IF 76 / 62 IF 55 / 54 IF
Outside Air c
0 cfm Supply Fan Cooling Coil
1,680 cfm
76 / 62 OF
56 / 54 IF
48.1 % ROOM
75 / 62 IF
EnergyPro6.3 b EnergySoR User Number. 7244 RunCode: 2014-11-OST10:09:46
ID: 13174U
Page 1 of 1
f
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Plan 2X
Date
11/5/2014
System Name
Res HVAC
Floor Area
2,709
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,463
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
29,699
2,866
830
30,249
Total Output Stuh
89,000
0
Output Btuh/s tt
32.9
1,644
1,343
CoolingSystem
0
0
Output per System /
46,500
01
0 _ 0
0
Total Output Btuh
46,500
0
2,866
0
Total Output(Tons)
3.9
1,644
1,343
Total Output Bluh/s tt
17.2
Total Output s ft/Ton
699.1
32,987
32,935
Air System
CFM per System
1.680
HVAC EQUIPMENT SELECTION
Airflow cfm
1,680
15/12/80%
31,680
7,878
89,000
Airflow cfm/s ft
0.62
Airflow cfmrron
` 433.5
-
Outside Air %
0.0 %
Total Adjusted System Output 31,680
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
7,878 89,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Tem eratures at Time of Heating Peak
26 OF 69 IF
Outside Air C•~
0 clm Supply Fan
1,680 dm
69 IF
69 IF 105 IF
,
Heating Coil
104 IF
ROOM
70 IF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112178 IF 76 / 62 IF 76 / 62 IF 55 / 54 IF
c ,
Outside Air c
0 clm Supply Fan Cooling Coil 56 / 54 IF
1,680 drn
_ 48.1 % ROOM
76 / 62 OF 75 162 IF
I
EnergyPro 6.3 by EnergySoft User Number. 7244 RunCode: 2014-11.05T1O:10:34 ID: 13174U
Page 1 or 1