14-0515 (AR) Title 24�i I 11 BUILDING ENERGY ANALYSIS REPORT I 0= PROJECT: Mr. & Mrs. Randy Eifler 81-695 Brown Deer Park La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: ARTim.-Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 LDA-rE ®`F' LA QUA�- LDING & SAF AP m,� OR C h°UCT C Job Number: ApR 22�h4 BY _ .,pcakt9T� Date: 4/28/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. RunCode: 20140428709:05:16 ID: l • CJ PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Randy Eifler Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/28/2014 Project Address 81-695 Brown Deer Park La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,209 Addition 304 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-30 3,905 Existing Wall Wood Framed R-19 2,777 Existing Door Opaque Door None 24 Existing Slab Unheated Slab -on -Grade None 4,209 Perim = 358' Existing Roof Wood Framed Attic R-38 3 Ext=R-7.0 New Wall Wood Framed R-19 196 New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Front (N) 26.4 1.040 0.63 none none Bug Screen Existing Front (N) 8.6 0.550 0.55 none none Bug Screen Existing Front (N) 43.0 0.550 0.55 none none Bug Screen Removed Left (E) 126.0 0.550 0.55 none none Bug Screen Existing Left (E) 82.0 0.550 0.55 none none Bug Screen Removed Rear (S) 18.0 0.550 0.55 none none Bug Screen Removed Rear (S) 278.4 0.550 0.55 none none Bug Screen Existing Right (W) 137.6 0.550 0.55 none none Bug Screen Existing Left (E) 24.0 0.550 0.55 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Fumace 80% AFUE Split Air Conditioner 12.0 Setback Existing rSEER r y LA /�'� C7A ee• r % .Ii HVAC DISTRIBUTION Location HeatingCoolingR, �� � & MvctTy DE A Duct LoaationAPPP,'Value� Status HVAC 1 existing Ducted Cy Ducted Attic, Ceiling IA s, vented" H CONS 4r2(W ir`TA, , Existib UH WATER HEATING Qt Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-04-28709:05:16 /D: Page 3 of 21 17J r-1 L-A t J PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Mr. & Mrs. Randy Eifler Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 4/28/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Cil - --7-A BUILDING & QU /-AHPR0 C %aUNSTRUCTION ` DATE By I Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 20140428709:05:16 /D: Page 4 of 21 0 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. & Mrs. Randy Eifler ❑ Multi Family m Existing+ Addition/Alteration 4/28/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.55 2.69 0.86 Space Cooling 110.55 102.87 7.68 Fans 23.69 22.00 1.70 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 137.80 127.56 10.24 Percent Better Than Standard: 7.4% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 630 35 Fuel Available at Site: Natural Gas (E) 1,123 150 Raised Floor Area: 0 (S) 648 278 Slab on Grade Area: 4,209 (K9 1,197 138 Average Ceiling Height: 10.5 Roof 3,908 0 Fenestration Average U -Factor: 0.57 TOTAL: 601 Average SHGC: 0.55 Fenestration/CFA Ratio: 14.3% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author C1 F U, (�(��NT/� Company Scott Design and Title 24, Inc, E3U1e t °„;��t , — 282014 Address 77-085 Michigan Drive Name Tim Scott Uri4`' , p City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 1 ed VED Date The individual with overall design responsibility hereby certifies that the propose building derprWrt:estt t' b in th's set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, Ad with any other calculations submitted with this permit application, and recolgnizes:that compliance{using duct desig , duct sealing, verification of refrigerant charge, insulation installation quality; -and building envelope sealing -require - installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Robert Pitchford 1 Address Name City/State/Zip Palm Desert Ca 92211 Phone (760) 346-2856 Signed License # Date Ene Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 20140428709:05:16 ID: Page 5 of 21 F--1q lu C6 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Mr. & Mrs. Randy Eifler Building Type m Single Family O Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/28/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 3,905 0.031 R-30 0 20 Existing 4.2.1-A20 Existing Residence Wall 571 0.074 R-19 0 90 Existing 4.3.1-A5 Existing Residence Door 24 0.500 None 0 90 Existing 4.5.1-A4 Existing Residence Wall 136 0.074 R-19 0 90 Removec 4.3.1-A5 Existing Residence Wall 777 0.074 R-19 90 90,Existing 4.3.1-A5 Existing Residence Wall 167 0.074 R-19 90 90 Removec 4.3.1-A5 Existing Residence Wall 161 0.074 R-19 180 90 Removec 4.3.1-A5 Existing Residence Wall 370 0.074 R-19 180 90 Existing 4.3.1-A5 Existing Residence Wall 1,059 0.074 R-19 270 90 Existing 4.3.1-A5 Existing Residence Slab 3,905 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 3 0.022 R-38 7.0 None 0 20 New 4.2.1-A9 Once Addition Wall 196 0.074 R-19 90 90 New 4.3.1-A5 Office Addition Slab 304 0.730 None 0 180 Existing 4.4.7-A 1 Office Addition FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 26.4 1.040 Default . 0.63 Default 0 Existing Entry Door Existing Residence 2 Window 8.6 0.550 Default 0.55 Default 0 Existing Double NonMetal Tint Existing Residence 3 Window 40.0 0.550 Default 0.55 Default 0 Removed Double NonMetal Tint Existing Residence 4 Window 3.0 0.550 Default 0.55 Default 0 Removed Double NonMetal Tint Existing Residence 5 Window 18.0 0.550 Default 0.55 Default 901 Existing Double NonMetal Tint Existing Residence 6 Window 18.0 0.550 Default 0.55 Default 90 Existing Double NonMetal Tint Existing Residence 7 Window 3.0 0.550 Default 0.55 Default • 90 Existing Double NonMetal Tint Existing Residence 8 Window 18.0 0.550 Default 0.55 Default 90 Existing Double NonMetal Tint Existing Residence 9 Window 18.0 0.550 Default 0.55 Default 90 Existing Double NonMetal Tint Existing Residence 10 Window 3.0 0.550 Default 0.55 Default 90 Existing Double NonMetal Tint Existing Residence 11 Window 12.0 0.550 Default 0.55 Default 90 Existing Double NonMetal Tint Existing Residence 12 Window 12.0 0.550 Default 0.55 Default 90 Existing Double NonMetal Tint Existing Residence 13 Window 24.0 0.550 Default 0.55 Default 90 Existing Double NonMetal Tint Existing Residence 14 Window 64.0 0.550 Default 0.55 Default 90 Removed Double NonMetal Tint Existing Residence 15 Window 18.0 0.550 Default 0.55 Default 180 Removed Double NonMetal Tint Existing Residence 16 Window 192.0 0.550 Default 0.55 Default 1801 Existing Double NonMetal Tint Existing Residence (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID ID Exterior Shade Type SHGC Window H t Wd Overhanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 1 Bug Screen 0.76 r 2 Bug Screen 0.76 1 K; Y V f- r r ,� ,- ' l 3 Screen 0.76 4 Bu Screen 0.76 A ��.�r-Yi11vi & S,AO=FTr 5 Bug Screen 0.76 6 Bu Screen 0.76 �� ' vt b 1 1 7 Bug Screen 0.76 L . S -h 8 Bug Screen 0.76 y -11 9 Bug Screen 0.76 _ 10 Bug Screen 0.76 I ✓" C - -_ Bly 11 Bug Screen 0.76 - ---- - -- -_ _- - 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 1 0.761 1 EnergyPro, 5.1 by EnemySoft User Number: 6712 RunCode: 20140428709:05:16 ID: Page 6 of 21 • Ll CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Mr. & Mrs. Randy Eifler Building Type m Single Family ❑ Addition Alone ❑ Multi Family la Existing+ Addition/Alteration Date 1412812014 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 36.0 0.550 Default 0.55 Default 180 Existing Double NonMetal Tint Existing Residence 18 Window 21.6 0.550 Default 0.55 Default 180 Existing Double NonMetal Tint Existing Residence 19 Window 3.6 0.550 Default 0.55 Default 180 Existing Double NonMetal Tint Existing Residence 20 Window 21.61 0.550 Default 1 0.55 Default 1 180 Existing Double NonMetal Tint Existing Residence 21 Window 3.6 0.550 Default 0.55 Default 180 Existing Double NonMetal Tint Existing Residence 22 Window 3.0 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 23 Window 3.0 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 24 Window 3.0 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 25 Window 20.0 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 26 Window 3.0 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 27 Window 13.2 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 28 Window 13.2 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 29 Window 13.2 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 30 Window 6.0 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 31 Window 18.0 0.550 Default 0.55 Default 270 Existing Double NonMetal Tint Existing Residence 32 Window 1 18.01 0.550 1 Default 1 0.55 Default 2701 Existing Double NonMetal Tint Existing Residence (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 ,- 19 Bug Screen 0.76 ; ' • + I r - r .ji ' " 20 Bug Screen 0.76 _ 21 Bu Screen 0.76 ( `' "��' r L SPT 1 22 Bug Screen 0.76 �= 1- 23 Bug Screen 0.76 p c - "v 24 Bug Screen 0.76 ' 1V IIU 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 - 29 Bug Screen 0.76 30 Bug Screen 0.76 31 1Bug Screen 0.76 32 IBug Screen 0.76 EnergyPro 5.1 ;-y EnergySoft User Number: 6712 RunCode: 2014-04-28709:05:16 /D: Page 7 of 21 1� CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Mr. & Mrs. Randy Eifler Building Type 0 Single Family O Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/28/2014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 24.0 0.550 1 Default 0.55 Default 270 Existing Double NonMeta/ Tint Existing Residence 34 Window 24.0 0.550 Default 0.55 Default 90 New Double NonMeta) Tint Office Addition 35 Window 18.0 0.550 Default 0.55 Default 90 Removed Double NonMeta/ Tint Office Addition (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Ri ht Fin ID Exterior Shade Type SHGC H t Wd Len H t I LExt I RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 ; I tA7 e- r— 35 Bug Screen 0.76 R� ,� �Y� (� M�\ITA -� IVUN r° �;, " "'� o .I:z - 3 Y ►. �- " "' RV 1 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-04-28T09:05:16 ID: Page 8 of 21 • L_I 0 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Mr. & Mrs. Randy Eifler Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1412812014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC 1 existing Existing Residence 3,905 41,003 2002 Office Addition 304 3,040 Totals 1 3041 3,9051 01 0 HVAC SYSTEMS System Name Qty. Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 existing 3 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC 1 existing Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard r— - I toff I I OF 1 A QI IIN11-a— rr MULTI -FAMILY WATER HEATING DETAILS HYDRONI,C HEATING`$YSTEM PIPING Control Hot Water Piping Length (ft) o y Q /1t`-` 1 FOR CONS Sem Name t -RUCTI Pipe 11Ce.n Jh N Pipe -aametei Insul. Thick. Qty. HP Plenum Outside Buried -EnemyAro 5.1 by EnemySoft User Number. 6712 RunCode: 2014-04-28T09:05:16 ID: Page 9 of 21 4 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Mr. & Mrs. Randy Eifler Date 1412812014 NOT Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 4150(b): Loose fill insulation shall conform with manufacturer's installed desi n labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent LI -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e uipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)l B: Unfired storage tanks, such as storage tanks or backup tanks for solar w�ter"� eating=syptlm4or kotherlindi rec( hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insO-Qtion R -value is inti cate1d�on the exterior of the tank. N BUILDING & SAFFTY nI §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculatin�g)systern djestir, ength of recirculatingsections of hot water pipes are insulated per Standards Table 150-B. �r U V E 11 I §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated%betQe a t�.iUoj(col'qd indir ct hot water tank shall be insulated to Table 150-B and Equation 150-A. I §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Stand rds Table 123-A. I DATE BY 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture a ui ment-maintenance=and-wimd. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2014-04-28709:05:16 /D: Page 10 of 21 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date r. & Mrs. Randy Eifler 1412812014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction or built -u connections for future solar heatin . utdoor ools ors as that have a heat um or as heater shall have a cover. Lreturnnes ools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or d to run onl Burin off eak electric demand eriods. sidential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as -determined by §130(d), and shall not contain a medium screw -base socket. n►-.- K 4150(k)6: Li htin integral to exhaust fans, in rooms other than kitchens, shall meet ithe_avy licable(re uirements of; 15Q k ._ X`0l " if' Y 1 V 150(k)7: All switchingdevices and controls shall meet the requirements of 150 k 7. �fl�(� $� �A` 4. . _ r §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lightinglin kitchens s shall b`e'hgli efficacy. s �M y EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for -dwelling units largerltha 2,500 ftz ay be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kit(hen aree controlled by a•ma Aural on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and a�I p��maneritly installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utilityjpoi s are high efficacy and controlled by a manual -on occupant sensor. 1 §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than`20 watts=of power pe inear-foot_of illuminated cabinet. EnergyPro5.1 by EnergySoft User Number: 6712 Run Code: 20140428709:05:16 /D: Page 11 of 21 r 4 i MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date r. & Mrs. Randy Eifler 4/28/2014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT, APPROVED P PROVED RUCTION DATE _�� By EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 20140428709:05:16 /D: Page 12 of 21 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. & Mrs. Randy Eifler Date 4/28/2014 System Name HVAC 1 existing Floor Area 4,209 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 2.792 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 55,761 0 4,728 01 0 0 4,728 1 65,217 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 71,000 6,887 1,321 56,416 Total Output Btuh 213,000 Output Btuh/s ft 50.6 4,008 Cooling System 0 Output perSystem 48,000 0 0 0 Total Output Btuh 144,000 6,887 0 Total Output Tons 12.0 4,008 Total Output Btuh/s ft 34.2 Total Output s ft/Ton 350.8 1 64,432 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 4,800 Existing HVAC 105,319 9,729 213,000 Airflow cfm/s ft 1.14 Airflow cfm/Ton 400.0 213,000 F Jan 1 AM Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 105,319 9,729 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 71 OF Outside Air 0 cfm Supply Fan 4,800 cfm 71 OF 71 OF 113 OF Heating Coil 112 OF ROOM 72 OF CI T 1 �� 1 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 1 DIAIr-, " Ui -r 112 / 78 OF 71 / 58 OF 71 / 58 OF 50 / 49 °F/-��PR®VE p c Outside Air c 0 cfm Supply Fan Cooling Coil 4,800 cfm 71 / 58 OF 4 DEpT CON f ►v A7E N —'�� gy 51 / 50 OF 48.0% R 70 / 58 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201404-28T09:05:16 ID: Page 13 of 21 C • ROOM HEATING PEAK LOADS Project Name Mr. & Mrs. Randy Eifler Date 4/28/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Floor Area 3,905.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT *F Btu/hr R-30 Roof Attic 3,905.0 0.0310 X 46 = 5,569 R-19 Wall (W. 19.2x6.16) 2,777.0 0.0740 X 46 = 9,453 Entry Door 26.4 1.0400 X 46 = 1,263 Wood Door 24.0 0.5000 X X X X X 46 = 46 = 46 = = = 552 Double NonMetal Tint 550.6 0.5500 13,930 Slab -On -Grade perim = 336.0 0.7300 11,283 X X = = X = X X X X X = = = = = X = X X = = X X = = X X X X -X = = = = = r--/_ B P,L Wtv 1, FXV,PIOVE x b��� FE ; �'`'Pi111is. ► STRU DF i n► 2,049 through an interior surface X 3,905 X Area another room DATE L _�� 10.50 X 0.342/ Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction Page Total By igp AT 6 = 1,458 TOTAL HOURLY HEAT LOSS FOR ROOM 53,507 EnergyRro 5.1 by EnergySoft User Number.- 6712 RunCode: 20140428709:05:16 /D: Pae 15 of 21 • • ROOM HEATING PEAK LOADS Project Name Mr. & Mrs. Randy Eifler Date 4/28/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Addition Floor Area 304.0 ft' Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area U -Value AT °F Btu/hr 46 = 3 46 = 667 46 = 607 46 = 739 = = -� In •" 1:)T. ED= n i8D� l 2,017 g /10_461 _46 = 892 R-38 Roof(R.38.2x14.16) 3.4 X X X 0.0220 X 0.0740 X 0.5500 X R-19 Wall (W. 19.2x6.16) 196.0 Double NonMetal Tint 24.0 Slab -On -Grade perim = 22.0 X X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X �r r X x FO to anot er room DATE 10.-00"X--0,36,0_ Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 304 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 2,909 Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 20140428709:05:16 /D: Pae 16 of 21 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Randy Eifler 1 4128/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,905.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Orientation R-30 Roof Attic R-19 Wall (W. 19.2x6.16) Wood Door R-19 Wall (W. 19.2x6.16) R-19 Wall (W. 19.2x6.16) R-19 Wall (W 19.2x6.16) (N) (N) (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 3,905.0 0.0310 56.0 571.0 0.0740 23.0 24.0 0.5000 23.0 777.0 0.0740 33.0 369.6 0.0740 26.0 1,059.4 0.0740 33.0 0.0 31.4 3.0 64.1 0.0 31.4 18.0 64.1 0.0 31.4 18.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenectratien Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Internal Gain Orientatinn (N) (N) (E) (E) (E) (E) (E) (E) (E) Btu/hr 6,779 972 276 1,897 711 2,587 I 13,2231 Shaded Area X X X X X X X X1 X GLF + + + + + + + + + Unshaded Area X X X X X X X X X GLF = = = = = = = = 0.0 44.2 26.4 44.2 0.0 31.4 8.6 31.4 0.0 31.4 18.0 64.1 0.0 31.4 18.0 64.1 0.0 31.4 3.0 64.1 0.0 31.4 18.0 64.1 0.0 31.4 18.0 64.1 0.0 31.4 3.0 64.1 0.0 31.4 12.0 Page Total Occupants 4.0 Occupants X 230 Btuh/occ. _ Equipment 1.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.94 X 241.80 X 2 - Ty OF ' ^ QUINT, Sensible CFM ELA AT BUILDING &SAF _ ETY DPP - TOTAL HOURLY SENSIBLE HEAT GAIN FOR R Latent Gain CONSTRUCTION Occupants 4.0 Occupants X DATE 200 Btuh/occ. Infiltration: 4,771 X 0.94 X 241.80 X 0.00523 = Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM biumr 1,166 270 1,153 1,153 192 1,153 1,153 192 769 7.202 Btu/hr 920 1,600 10107 52,954 Btu/hr 800 5,647 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Randy Eifler 1 4/28/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,905.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranoe: 34 OF Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = I= = = = = = GLF = = = = = = = = = 0.0 31.4 12.0 64.1 0.0 31.4 24.0 64.1 0.0 31.4 192.0 31.5 0.0 31.4 36.0 31.5 0.0 31.4 21.6 31.5 0.0 31.4 3.6 31.5 0.0 31.4 21.6 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fpnpctratinn Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Oripntatinn (E) (E) (S) (S) (S) (S) (S) (S) (tM Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 31.4 12.0 64.1 0.0 31.4 24.0 64.1 0.0 31.4 192.0 31.5 0.0 31.4 36.0 31.5 0.0 31.4 21.6 31.5 0.0 31.4 3.6 31.5 0.0 31.4 21.6 31.5 0.0 31.4 3.6 31.5 0.0 31.4 3.0 64.1 Page Total Btu/hr 01 Btu/hr 769 1,538 6,055 1,135 681 114 681 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X ,t-1;600 ,B(u = 1,600 CITY OF LA QUIN Infiltration: 1.064 X 0.94 X 241.80 X 42 = BUILDING &,SAFE 0,107 Air Sensible CFM ELA eT N DEPT, TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM I r'vH UONVgTR► 152,9541 Latent Gain Occupants 4.0 Occupants X-200 _gtu, BY - 800 Infiltration: 4,771 X 0.94 X 241.80 X 0.00523 = 5,647 Air Sensible CFM ELA AW •TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6.447 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name7412812014 ate Mr. & Mrs. Randy Eifler ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,905.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranoe: 34 OF ue Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = = 0.0 31.4 3.0 64.1 0.0 31.4 3.0 64.1 0.0 31.4 20.0 64.1 0.0 31.4 3.0 64.1 0.01 31.4 13.2 64.1 0.0 31.4 13.2 64.1 0.0 31.4 13.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Existing Window Existing Window Existing -Window Existing Window Existing Window Existing Window Existing Window Existing Window Existing Internal Gain Orientation r►M (►M (KO (tM (tM (tM (►M (►M (►M Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 31.4 3.0 64.1 0.0 31.4 3.0 64.1 0.0 31.4 20.0 64.1 0.0 31.4 3.0 64.1 0.01 31.4 13.2 64.1 0.0 31.4 13.2 64.1 0.0 31.4 13.2 64.1 0.0 31.4 6.0 64.1 0.0 31.4 18.0 64.1 4.0 Occupants X 1.0 Dwelling Unit X Infiltration: 1.064 X 0.94 X 241.80 X Air Sensible CFM ELA AL HOURLY SENSIBLE HEAT GAIN FOR ROOM Page Total Btu/hr 171 Btu/hr 192 192 1,281 192 846 846 846 384 1,153 tsiwnr 230 Btuh/occ. = 920 ]l,�IY OF LA QUIIN =BUILDING & SAFETY DE I APPROVED Latent Gain I DATE gY Occupants 4.0 Occupants X z 200"Btuhfocca-- Infiltration: 4,771 X 0.94 X 241.80 X 0.00523 = Air Sensible CFM ELA AW 1,600 10,107 52,954 I/hr 800 5,647 • 0 4. 4 .i RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name7412812014 ate Mr. & Mrs. Randy Eifler ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,905.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window Existing (VV) 0.0 X 31.4 + 18.0 X 64.1 = 1,153 Window Existing (IM 0.0 X 31.4 + 24.0 X 64.1 = 1,538 X + X = X + X - X + X = X + X - X + X - X + X - X + X = Page Total 2,691 Internal Gain Btu/hr— tu/hrOccu ants 4.0 Occupants X Occupants 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 241.80 X 42 = 10,107 Air Sensible CFM ELA AT ff!T� ®F LA . C -I 11h TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM ClUILUI fG & Latent Gain APPROVED - NSTF3lIC Occupants 4.0 Occupants X 100 Btuh/occ. �QN 800 Infiltration: 4,771 X 0.94 X 241.80 X 0.00523 = DATE-- BY 5,6471 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,447 EneravPro 5.1 by Ene-mySoft User Number: 6712 Run Code: 20140428709:05:16 /D: Page 20 of 21 • 4 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Randy Eifler 1 4/28/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 304.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (N) 3.4 X 0.0220 X 56.0 = 4 R-19 Wall (W. 19.2x6.16) (E) 196.0 X 0.0740 X 33.0 = 479 X X = X X = X X = X X = X X = X X = X X = Page Total 1 483 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window New (E) 0.0 X 31.4 + 24.0 X 64.1 = 1,538 X + X - X + X - X + X - X + X = X + X - X + X - X + X - X + X = Page Total 1,538 Internal Gain Btu/hr— tu/hrOccu ants 0.0 Occupants X Occupants 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 18.82 X 42 = 787 Air Sensible CFM ELA AT CITY OE AQf III\ I -t - TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM ILU - & c, ter-, —_ -' _ ''2, 07 Latent Gain APPROVED Btu/h Occupants o.0 Occupants X 'dfuED hPocRNSTRUCTa 0 Infiltration: 4,771 X 0.94 X 18.82 X 0.00523 - D-�_ BY 440 fTE Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 440 EnergyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2014 04-28 70 9:05:16 /D: Page 21 of 21