Loading...
08-0366 (SFD) Title 24TITLE 24 REPORT Title 24 Report for: SINGLE HOUSE, LOT 2 o - �f565+ BREVA LA QUINTA, CA Project Designer: STEVEN PHILLIPS - ARCHITECT, A.I.A. 23817 LA CADENA DR., #101 LAGUNA HILLS, CA 92653 (949) 768-7244 9 Report Prepared By: RAYMOND M. ZHONG PERFECT DESIGN & ENGINEERING, INC. 2416 W. Valley Blvd. Alhambra, CA 91803 (626) 289-8808 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA BY Job Number: P061676R Date: 11/19/2007 N01V -2 .1 2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: P061676R User Number: 1919 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 11 13 14 19 24 30 I " EnergyPro 4.3 by EnergySoft Job Number: P061676R User Number: 1919 1 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R _SI.NG.L.E_NO-U_S.E.,_L.O_T_2 628 MA I.N_EL00R,_EAU_3 AREA 11./_1.9/_200-7 Project Title 2,466 OPAQUE SURFACES Date -5-65-BRE-V-A- -L Q.U_INTA Cay. Cont. Azm. Tilt Project Address Wood_ 0_ Building Permit # -PER F_EC_T_DESI_G_N_&_ENGI.N.E.E.RI.NG,J.NC. (626)-289-8808 Wall_ Documentation Author 30_ Telephone Plan Check/Date _Ene.r_g_y_P_r_o 90 15 Field Check/Date Compliance Method _0_.0.6.9_ _None_.R-1.3...0_ Climate Zone 8 _n/a TDV Standard Proposed Compliance _0.102 (kBtu/sf-yr) Design Design Margin Wall_ Space Heating 2.70 3.11 -0.40 _9.0_9.0 Space Cooling 54.09 52.13 1.97 1.20_ Fans 7.69 7.43 0.27 9.0. Domestic Hot Water 3.03 2.26 0.78 _0.0.69_ -None-R-13.0- Pumps 0.00 0.00 0.00 None_ Totals 67.52 64.92 2.60 1.80_-9.0 Percent better than Standard: ,Roof 3.9% 628_ _0..0.3.5 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: [] Single Family ❑ Addition Total Conditioned Floor Area: 7,964 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (E) 90 deg Fuel Type: Natural Gas Fenestration: Area: 1,047 ft2 Avg. U: 0.34 Ratio: 13.1% Avg. SHGC: 0.27 BUILDING ZONE INFORMATION Zone Name Floor Area Volume 13ASEMEN_T_EL.,EAU_2_AREA 1.,595 .MAI N_ELO0.R,_EAU_1_AREA 628 MA I.N_EL00R,_EAU_3 AREA 1.,345 .MAI.N_F_LOOR,_EAU-4.AREA 2,466 OPAQUE SURFACES I 1 t' A t 4 1,355 6.,28.0 1.3,450 _24.6.6.0 Raised Floor Area: .02:A1.0 0 ft2 New nsU a Ion C . 5,401 ft2 Type Frame Area U -Fac. Cay. Cont. Azm. Tilt ,Roof Wood_ 0_ _0.0.35_ -R_30_ _R=O..0_ 0_ 22 Wall_ Wood_ 30_ 0.1.02 -R=13_ _R-0..0_ _2.7.0_ 90 Wall_ None_ 3.92_ _0_.0.6.9_ _None_.R-1.3...0_ _2.7.0__9.0 8 _n/a Wall_ Wood_ 21. _0.102 -R1.3_ _R:0..0_ -9.0_ 9.0 Wall_ None_ 4.0.0_ _0.0.6.9 None_ _13-1.1.0_ _9.0_9.0 N.ew Wall- Wood- 1.20_ _0102_ _R-1.3_ _R=0...0_ 0 9.0. Wall_ None_ 251. _0.0.69_ -None-R-13.0- 0__9.0 _0.9=A3 Wall_ None_ 49.0_ -0.069- -None-.R--13.0- 1.80_-9.0 NE.W_MAIN_ELOOR ,Roof Wood_ 628_ _0..0.3.5 _R-3.0_ _R=0...0 0__22 New Wall_ Wood_ 1.97_ _0102_ _13_1-3_ _R=0.0_ _2.7.0__9.0 Wall_ Wood_ 265_ _0.102_ -R=t3_ _R=0_0_ _9.0__9.0 Wall_ Wood_ _2.48. 0.102 -R=13_ _ERO._0_ 0_ 9.0 Wall_ Wood_ 232 0.102-R=13- -ER0-0- 1.80_9.0 .Roof Wood_ 1,3_4.5_ _0._0.35 -R:.3-0- -R--O-..O- -0--22 Wall_ Wood_ x_92_ _01.02_ _R-1.3.08=0...0_ _2.7_0__9.0. Wall_ Wood_ 25.5_ -0-1-02- -R_1.3__R 0..0_-9.0__9.0. Wall_ Wood_ 35Z _0 1.02_ _R=t3_ --3=0..0_ 0__90 Wall_ Wood_ 845_ _01.02 -R43_ _R=0_0_ 1.80__9.0 .Roof Wood_ _2,386_ -0_0.35_ -EL30_ _R=0..0_ 0_ 22 Wall_ Wood_ 1_4.9_ _0..1.02. _R=13_ _R-0..0_ _2.7.0.9.0. Wall_ Wood_ 23.0_ _0.102_ _R--]_3_ _R-0..0_ 90_9.0 ,Wall_ Wood_ 528_ _0.102 -13_1-3_ _R=0...0_ 0__9.0 .Wall_ Wood_ 1.26_ _0.102. _R_1 -3__R-0..0_ 1.8.0__9.0. Roof_ Wood_ 7_4_ _0.0.35_ -R=30_ _R=0..0_ 0_ 22 Wall_ Wood_ 20_ _0.1.02_ _R=1.3_ _R=0_0_ _2.7.0__9.0 Raised Floor Area: .02:A1.0 0 ft2 New Slab on Grade Area: NEW -BASEMENT -El -R. 5,401 ft2 1.2=A9 Average Ceiling Height: New 9.6 ft NEW -BASEMENT -El -R. Number of Dwelling Units: 1.00 .NEW BASEMENT ELR. Number of Stories: _0.9=A3 3 New # of Thermostat Vent 12A9 Units Zone Type Type Hgt. Area -0.20_ Conditioned -Setback_ 8 -n/a NE.W MAIN_ELO-OR _0._0.8_ Conditioned_ -Setback_ 8 _n/a New 01.7 Conditioned_ _Setback_ 8 _n/a 09=A3 0.31_ Conditioned_ Setback_ 8 _n/.a NE.W MAIN_EL.00R - Gains Condition Y / N Status JA IV Reference Location / Comments New .02:A1.0 NEW -BASEMENT -El -R. New 0.9=A3 NEW -BASEMENT -El -R. N.ew 1.2=A9 NE.W BASEMENT ELR. New _09=A3 NEW -BASEMENT -El -R. N.ew 1.2=A9 .NEW BASEMENT ELR. N.ew _0.9=A3 NEW-BAS.EMEN_T_ELR. New 1.2=A9 NEW -BASEMENT -El -R. New 12A9 NEW -BASEMENT -El -R. New _02=A_1.0 NEW -MAIN -EI -0-013 N.ew _0.9=A3 NE.W MAIN_ELO-OR New .0.9=A3 NEW -MAIN -EI -0.0,B New .0.9=A3 .NEW MAIN_EL.O.OR N.ew 09=A3 NEW. -MAIN -F -1 -10 -OR New _02=A10 NE.W MAIN_EL.00R - N.ew _0.9=A3 NE.W__MAIN_EL.00R N.ew _0.9=A3 NE.W__MAIN_ELOOR New .09=A3 NE.W. _MAIN_ELO.O.R New _0.9=A3 NE.W_ _MAIN_ELO.O.R New _02=A1.0 .NEW MAIN_ELO.O.R_ New _0.9=A3 NEW MAIN_F_LOOR _ New .0.9=A3 NE.W_MAIN_EL0013 New _0.9=A3 NE.W_MAIN_ELOOR N.ew _0.9=A3 .NEW MAIN_ELOOR New _02=A1.0 .NEW MAIN_ELOO.R_ New _0.9=A3 NEW MAIN_ELO.OR_ Run Initiation Time: 11/19/07 17:23:42 Run Code: 1195521822 ' EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:3 of 35 _ i Certificate Of Compliance : Residential ❑ Addition (Part 1 of 4) CF -1 R _SI.NG.LE_MGU_S_E,_LC2T_2 ft2 Frame 111_1.9/_2QQ7 Project Title Existing Floor Area: n/a Date 56.5_B.RE_V_A-LA QUI.N_T_A (E) 90 deg Raised Floor Area: 0 Project Address Fuel Type: New Building Permit # EEC_T_DESI_GN_&_ENG I.N.E.E.R.ING,_ NC. (626)-289-8808 -- -PER Documentation Author Telephone Plan Check/Date _En.e.r_g_y_P_r_o Area: 15 I Field Check/Date Compliance Method Wood_ Climate Zone _0..035_ TDV Standard Proposed Compliance Wall_ (kBtu/sf-yr) Design Design Margin _R_1.3_ _R=0...0_ Space Heating 2.70 3.11 -0.40 Wood_2.4_4_ Space Cooling 54.09 52.13 1.97 -9.0--g.0 Fans 7.69 7.43 0.27 Z04_ Domestic Hot Water 3.03 2.26 0.78 Pumps 0.00 0.00 0.00 _0.1.02_ Totals 67.52 64.92 2.60 Percent better than Standard: Building Type: n Single Family ❑ Addition Total Conditioned Floor Area: 7,964 ft2 Frame ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (E) 90 deg Raised Floor Area: 0 ft2 Fuel Type: New Natural Gas Slab on Grade Area: 5,401 ft2 Fenestration: 0_-9.0 Average Ceiling Height: 9.6 ft Area: 1,047 ft2 Avg. U: 0.34 Number of Dwelling Units: 1.00 Wood_ Ratio: 13.1% Avg. SHGC: 0.27 Number of Stories: 3 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area FAU_5_AREA 1 930 11,945 _0.24_ Conditioned, Setback_ 8 - _n/a OPAQUE SURFACES _0.9=A3 Insulation Act. _0.9=A3 Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall_ Wood_ 308_ _0..1.02_ _R_1.3_ _R=0..0_ -9.0_-9.0 New ,Wall_ Wood_ 3.32 _0..1.02_-R_1.3__R=0...0 LO.F_T_SP_ACE 0_-9.0 Wall_ Wood_ 2]4 -0-1.02- _R_1.3_ _R=0...0_ 1.80_-9.0. Roof Wood_ 9.68_ _0..035_ -R=30_ _R=0...0_ 0_-22 Wall_ Wood_ 32.7_ _0..102. _R_1.3_ _R=0...0_ -27-0--9-0 Wall_ Wood_2.4_4_ _0..1.02_ -R_1.3_ _R=0..0_ -9.0--g.0 Wall_ Wood_ Z04_ _0.1.02_ _R_1.3_ _R=0_0_ 0__9.0 Wall- Wood- 69.5_ _0.1.02_ _R_1.3_ _R=0.0_ 1.80_ -9.0 Gains Condition Y / N Status JA IV Reference Location / Comments New _0.9=A3 .NEW MAIN_ELOOR N.ew _0.9=A3 NEW MAIN_ELOQR N.ew _0.9_A3 .NEW MAIN_F_LOO.R New _02=A1.0 LO.F_T_SEACE N.ew 0.9=A3 GET-SP New _0.9=A3 LQF_T_S.P_ACE New _09m13 LO.F_T_SP_ACE New 0.9=A3 LO.F_T_SP_ACE Run Initiation Time: 11/19/07 17:23:42 Run Code: 1195521822 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:4 of 35 i Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R SINGLE HOUSE, LOT 2 11/19/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 1_ Window Rear(_W)_ 1.5_.0 _0.3_4.0_NERC_0-2.7 NERC _2.7.0_ _9.0_ N.ewDouble_N.on_M.etal_Clear_(.5) _NEW BAS.EMEN_T_ELR._ 2 Window Front (E_ 15.0 0.340 NFRC 0_27 NFRC 90 90 New Double Non Metal Clear (5) NEW BASEMENT FLR. 3 Window Right (N) 118.0 0.340 NFRC 0_27 NFRC 0 90 New Double Non Metal Clear (5) NEW BASEMENT FLR. 4 Window Left (S) 0.0 0.340 NFRC 0_27 NFRC 180 90 New Double Non Metal Clear (5) NEW BASEMENT FLR. 5 Window Rear (W)_ 68.0 0.340 NFRC 0_27 NFRC 270 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 6 Window Front (Q- 0.0 0.340 NFRC 0_27 NFRC 90 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 7 Window Right (N)_ 0.340 NFRC 0_27 NFRC _� �Q New Double Non Metal Clear (5) NEW MAIN FLOOR 8 Window Left 24.0 0.340 NFRC 0.27 NFRC 180 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 9 Window Rear 76.0 0.340 NFRC 0_27 NFRC 270 94 New Qoubie Non Metal Clear (5) NEW MAIN FLOOR 10- Window Front (E)_ _ 0.0 0_340 NFRC 0_27 NFRC 90 9Q New Double Non Metal tear (5) NEW MAIN FLQOR 11 Window Right (N� 0.0 0.340 NFRC 0_27 NFRC 0 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 12 Window Left (S)_ 55.0 0.340 NFRC 0_27 NFRC 180 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 13 Window Reaf-(W)- -236,Q -0,3-4.0 -NER- -C 0.2.7. -NERC _2.7_0_ 90 New Double_Non-Metal_Clear_(5) _NE.W MAI.N_ELQOR 14 Window Front (E)_ 0.0 0.340 NFRC 0_27 NFRC 90 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 15 Window Right (N) 92.0 0.340 NFRC 0_27 NFRC 0 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 16 Window Left (S) 69.8 0.340 NFRC 0_27 NFRC 180 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 17 Window Rear (W) 0.0 0.340 NFRC 0_27 _NER.C. 270 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 18 Window Front (E) 0.0 0.340 NFRC 0_27 NFRC 90 90 New Double Non Metal Clear (5) NEW MAIN FLOOR 19 Window Right (N)_ 43.0 0.340 NFRC 0.27 NFRC _0 9Q New Double Non Metal Clear (5) NEW MAIN FLQOR 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade -Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 _ 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Tvoe (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Slab Perimeter Insulation None No Insulation 26-A1 New NEW BASEMENT FLR. Slab Perimeter PERIMETER LOSSES None No Insulation 26-A1 New Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 206 None No Insulation 26-A1 New NEW BASEMENT FLR. Slab Perimeter 104 None No Insulation 26-A1 New NEW MAIN FLOOR Slab Perimeter 178 None No Insulation 26-A1 New NEW MAIN FLOOR Slab Perimeter 153 None No Insulation 26-A1 New NEW MAIN FLOOR Slab Perimeter 96 None No Insulation 26-A1 New NEW MAIN FLOOR EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:5 of 35 , Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R SINGLE HOUSE, LOT 2 Project Title 11/19/2007 _ Date FENESTRATION SURFACES # Type Area True U -Factor' SHGCZ Azm. Tilt Cond. Location/ Stat. Glazing Type Comments .20. Wind.ow_Left_(.S)_ X1.0_ —0;.340 BERG 0.27 _NERC. X80_ 90_ NewDoub.I.eSlon-Metal_Ctear_(.5.) _NE1V MAIN_F_LOOR 21 Window Rear (W) 16.8 0.340 NFRC 0`27 NFRC 270 90 New Double Non Metal Clear (5) LOFT SPACE 22 Window Front (E)_ 100.0 0.340 NFRC 0_27 NFRC 90 90 New Double Non Metal Clear (5)� LOFT SPACE 23 Window Right (N) 30.0 0.340 NFRC 0_27 NFRC 0 90 New Double Non Metal Clear (5) LOFT SPACE 24 Window Left (S)_ 39.8 0.340 NFRC 0_27 NFRC 180 90 New Double Non Metal Clear (5) LOFT SPACE 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Tve SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. _ Hgt. 20 Bug Screen 0.76 _ 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Twe (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Tvoe Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments r Run Initiation Time: 11/19/07 17:23:42 Run Code: 1195521822 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P06167614 Page:6 of 35 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R SINGLE HOUSE, LOT 2 Project Title Condition Ducts Date 11/19/2007 HVAC SYSTEMS Heating Location Type Minimum Eff Cooling Type Minimum Eff Condition Status Thermostat Type BASEMENT FL.,FAU-2 AREA Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback MAIN FLOOR, FAU-1 AREA Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback MAIN FLOOR, FAU-3 AREA Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr gal) Status or RE Loss (%) Ext. _'PRONTO" RTG-42PVN (INDOOR) Large Gas All Pipes Ins 3 118,000 0 New 0.81 3.80% 12.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ftL Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: STEVEN PHILLIPS - ARCHITECT, A.I.A. Address: 23817 LA CADENA DR., #101 LAGUNA HILLS, CA 92653 Telephone: (949) 768-7244 Lic. #: Documentation Author Name: RAYMOND M. ZHONG Title/Firm: PERFECT DESIGN & ENGINEERING, INC. Address: 2416 W. Valley Blvd. _ Alhambra, CA 91803 Telephone: (signature) (date) (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: m 50 (date) (signature) (date) Run Initiation Tomeo 11/19/07 17*23*42 Run Code* 1195521822 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:? of 35 Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? BASEMENT FL.,FAU-2 AREA Ducted Ducted Attic 6.0 New Yes MAIN FLOOR, FAU-1 AREA Ducted Ducted Attic 6.0 New Yes MAIN FLOOR, FAU-3 AREA Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr gal) Status or RE Loss (%) Ext. _'PRONTO" RTG-42PVN (INDOOR) Large Gas All Pipes Ins 3 118,000 0 New 0.81 3.80% 12.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ftL Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: STEVEN PHILLIPS - ARCHITECT, A.I.A. Address: 23817 LA CADENA DR., #101 LAGUNA HILLS, CA 92653 Telephone: (949) 768-7244 Lic. #: Documentation Author Name: RAYMOND M. ZHONG Title/Firm: PERFECT DESIGN & ENGINEERING, INC. Address: 2416 W. Valley Blvd. _ Alhambra, CA 91803 Telephone: (signature) (date) (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: m 50 (date) (signature) (date) Run Initiation Tomeo 11/19/07 17*23*42 Run Code* 1195521822 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:? of 35 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R SINGLE HOUSE, LOT 2 Project Title Tested? MAIN FLOOR, FAU-4 AREA Ducted Ducted Attic Date 11/19/2007 HVAC SYSTEMS Heating Location Type Minimum Eff Cooling Type Minimum Eff Condition Status Thermostat Type MAIN FLOOR, FAU-4 AREA Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback FAU-5 AREA Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? MAIN FLOOR, FAU-4 AREA Ducted Ducted Attic 6.0 New Yes FAU-5 AREA Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. Btu/hr) _(gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: RAYMOND M. ZHONG Title/Firm: STEVEN PHILLIPS - ARCHITECT, A.I.A. Title/Firm: PERFECT DESIGN & ENGINEERING, INC. Address: 23817 LA CADENA DR., #101 Address: 2416 W. Valley Blvd. LAGUNA HILLS, CA 92653 Alhambra, CA 91803 Telephone: (949) 768-7244 Lic. #: Telephone: (626) 289-8808 Q pFESS (signature) (date) (signature) �O oND 1%4ENG (date) Enforcement Agency CID Name: uu rmn Title/Firm: C Exp. 11 Address: - Telephone: l'9l ChANtC �Q- Or CALIF (signature) (date) I EneravPro 4.3 by EnerovSoft User Number: 1919 Job Number P061676R Pane -8 of 35 1 _ Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R SINGLE HOUSE, LOT 2 11/19/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justitication and documentation submitted. I Plan i Field The DHW System ""PRONTO" RTG-42PVN (INDOOR)" is a Large Gas water heater with Pilot Loss = 0 btuh. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using t.t=t, approved testing andior verification methods and must be reported on the CF -4R installation certificate. Plan I Field The HVAC System "BASEMENT FL.,FAU-2 AREA" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "BASEMENT FL.,FAU-2 AREA" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. i The HVAC System "MAIN FLOOR, FAU-1 AREA" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "MAIN FLOOR, FAU-1 AREA" incorporates a HERS verified Refrigerant Charge test or a HERS verified jThermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The HVAC System "MAIN FLOOR, FAU-3 AREA" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "MAIN FLOOR, FAU-3 AREA" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The HVAC System "MAIN FLOOR, FAU-4 AREA" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "MAIN FLOOR, FAU-4 AREA" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The HVAC System "FAU-5 AREA" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "FAU-5 AREA" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:9 of 35 1 _ Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R SINGLE HOUSE, LOT 2 11/19/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- Plan I Field EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 10 of 35 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent, U -factor in metal frame ceiling. ❑ Q ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ElEl ❑X El�§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ R ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ 0 ❑ 1. Masonry and factory -built fireplaces have: , ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(9): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ Q ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ Q ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ Q ❑ Coefficient (SHGC), and infiltration certification. ❑ R ❑ 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. ❑ ER ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ 0 ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ Q ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ 0 ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1, First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ N ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ Q ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ Q ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ 1z ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ Q ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft . User Number: 1919 Job Number: P061676R Page: 11 of 35 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ o ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ X❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ O ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ o ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ X❑ ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ Q ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ Q ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section ill 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ 0 ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:12 of 35 Residential Kitchen Lighting Worksheet WS -5R SINGLE HOUSE, LOT 2 11/19/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts High Efficacy Quantity Watts Other Watts (2)13w Com pactFluo.Quad 4Pin(6"Recessed) Yes FX No 7 34.0 x 12 = 408 or 200w Recessed Incandescent - Yes I No. X1 2000. x 1 or 200 (1) 14w Linear Fluorescent T5 Elec Yes X1 No 1 18.0 x 5 _ 90 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No i x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes I No x = or YesNo x = or Yes No x - or Yes No x = or Yes No x = or • Yes No x = or Yes I No I_ x = or Yes 7 No x = or Total A: 498 B: 200 COMPLIES IF A _> B YES n NO ❑ 1 EnergyPro 4.3 by EnergySoft User Number: 1919 , Job Number: P061676R Page:13 of 35 1 MVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE SINGLE HOUSE, LOT 2 11/19/2007 SYSTEM NAME FLOOR AREA BASEMENT FL.,FAU-2 AREA 1,595 ENGINEERING CHECKS Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sqft) 55.8 Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 35.7 ` Total Output (sgft/Ton) 335.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.25 Airflow (cfm/Ton) 421.1 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 of Outside Air 0 cfm 69.4 of 69.4 of 0 Supply Fan 2000 'cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 573 12,186 139 501 18,666 0 1,127 1,250 01 0 0 0 011 0 0 0 0 1,127 1,250 14,440 139 21,165 CARRIER 38TXA-060/58STA-110-22 39,801 8,657 89,000 Total Adjusted System Output 39,801 8,657 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.40F ]0 105.0 of Heating Coil K Return Air Ducts 'I Supply Air Ducts 104.4 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0/72.5OF 75.5/61.5OF 75.5/61.6OF0 55.0/53.9OF %� J -1 Outside Air 0 cfm 75.5161.5 of Supply Fan 2000 cfm Cooling Coil h Return Air Ducts "I Supply Air Ducts 55.5 / 54.1 of 46.1% R.H. ROOMS 75.0/61.4OF EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 14 of 35 -IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE SINGLE HOUSE, LOT 2 11/19/2007 SYSTEM NAME FLOOR AREA MAIN FLOOR, FAU-1 AREA 628 GIN Number of Systems 1 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sqft) 55.7 Cooling System Output per System 22,400 Total Output (Btuh) 22,400 t 0 01 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 48 10,247 297 316 11,783 0 948 789 0 0 0 0 0 0 01 0 i 0 789., 948 12,143 297 CARRIER 38TXA-024/58STA-045-08 15,831 3,295 Total Adjusted System Output 15,831 3,295 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 13,361 35,000 35,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.1 OF 69.1 OF 105.0 OF Supply Air Ducts O Outside Air 0 cfm 104 1 cF. Supply Fan Heating Coil 800 I cfm ROOMS 70.0 of 69.1 of ' Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak I 110.0 / 72.5 of 76.1 / 61.8 of 76.1 / 61.9 OF 55.0 / 53.8 of Supply Air Ducts O Outside Air 0 cfm Supply Fan Cooling Coil 56.1 / 54.3 of 800 cfm FROOMS 46.4% R.H. 76.1/61.8 of 75.0 / 61.4 of h Return Air Ducts `i EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 15 of 35 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY :PROJECT NAME DATE SINGLE HOUSE, LOT 2 11/19/2007 SYSTEM NAME FLOOR AREA MAIN FLOOR, FAU-3 AREA 1,345 j .Number of Systems I 11 ;Heating System i Output per System 54,000 Total Output (Btuh) 1 54,000 Output (Btuh/sgft) 40.1 Cooling System Output per System 34,000 Total Output (Btuh) 34,000 Total Output (Tons) 2.8 Total Output (Btuh/sqft) 25.3 Total Output (sgft/Ton) 474.7 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM Sensible l i 741 15,766F---18 0 561 20,8871 0 j 1,3991 0 1,458 0 0 0 0 1 0 j 0� 11399 1,458 18,683 180 i i 23,684 Air System IHVAC EQUIPMENT SELECTION s i CFM per System 1,200 j . CARRIER 38TXA-036/58STA-070-12 24,194 4,803 j 54,000; ' Airflow (cfm) 1,200 Airflow (cfm/sqft) 0.89 I Airflow (cfm/Ton) 423.5 I Outside Air % ( ) 0.0 Total Adjusted System Output 24,194 4,803 54,000 j (Adjusted for Peak Design Conditions) Outside Air (cfm/sgft) 0.00 TIME OF SYSTEM PEAK Aug 2 pm F Jan 12 am j Note: values above given at ARI conditions ; EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak) 26.0 OF 68.9 OF 68.9 OF ■ 105.0 OF —T ir _ Out,, Air 0 cfm Supply Fan Heating Coil 1200 cfm 68.9 °F >, Return Air Ducts 14 b Supply Air Ducts `S 103.9 of ROOMS 70.0 OF ! DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0 / 72.5 OF _ 76.1 / 61.8 OF 76.1/61.80F . 55.0 / 53.8 °F Outside Air 0 cfm 76.1/61.8 of Supply Fan Cooling Coil 1200 cfm Supply Air Ducts 56.1 / 54.3 of 46.1% R.H. ROOMS 75.0 161.4 OF Return Air Ducts I I EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 16 of 35 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE SINGLE HOUSE, LOT 2 11/19/2007 SYSTEM NAME FLOOR AREA MAIN FLOOR, FAU-4 AREA 2,466 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sqft) 36.1 (Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 23.1 Total Output (sgft/Ton) 519.2 Alr $yStem CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 0.81 Airflow (cfm/Ton) 421.1 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF 69.2 OF 69.2 OF Outside Air 0 cfm 69.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 1,207 25,681 4 699 26,033 0 2,375 1,743 0 0 0 0 0 1 0 0 0 0 2,375 1,743 30,4321 -4 CARRIER 38TXA-060/58STA-110-22 40,668 7,896 Total Adjusted System Output 40,668 7,896 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 105.0 of Supply Fan Heating Coil 2000 cfm h Return Air Ducts `i 29,520 89,000 89,000 Jan 12 am Supply Air Ducts 104.2 of ROOMS 70.0 of (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 110.0 / 72.5 of 76.1 / 61.7 of 76.1 / 61.7 of 55.0 / 53.8 of O4 Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 56.1 / 54.3 of 2000 cfm 45.9% R.H. ROOMS 76.1 /61.7OF 75.0/61.30F Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 17 of 35 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME SINGLE HOUSE, LOT 2 'SYSTEM NAME FAU-5 AREA DATE 11/19/2007 i FLOOR AREA 1,930 ENGINEERING CHECKS SYSTEM LOAD iNumber of Systems 1 COIL CFM Total Room Loads 1,168 Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK I COIL HTG. PEAK! Sensible Latent I CFM I Sensible 24,853 484 721 26,858' '. 0 2,299 1,798; 0 0! 0 0 Oil 0i 0; o I-- o' i 2,299 11,798 1129,450 484 30,4_551 ; 'Heating System Output per System 89,000 Total Output (Btuh) 1 89,000 _ Output (Btuh/sgft) 46.1 !Cooling System Output per System 57,000 Total Output (Btuh) 57,000 ` Total Output (Tons) 4.8 Total Output (Btuh/sgft) 29'5 Total Output (sgft/Ton) 406.3 --- Air System HVAC EQUIPMENT SELECTION CFM per System 2,000 !CARRIER 38TXA-060/58STA-110-22 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 40,456 8,168 1 40,456 8,1681 Aug m -- f 89,000', --- - - 1 89,000 . Jan 12 am' Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.04 Airflow (cfm/Ton) 421.1 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions J i EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.2 of 69.2 OF ■ 105.0 of I Outside Air 0 cfm Supply Fan Heating Coil 2000 cfm 69.2 of Supply Air Ducts 104.2 of ROOMS 70.0 of a Return Air Ducts `j I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0 / 72.5 of 76.1 / 61.8 of 76.1 / 61.8 of . 55.0 / 53.8 of Outside Air 0 cfm 76.1 / 61.8 of Supply Fan Cooling Coil 2000 cfm Supply Air Ducts 56.1 / 54.3 of 46.2% R.H. LROOMSL 75.0 161.4 of Return Air Ducts i EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 18 of 35 ROOM LOAD SUMMARY PROJECT NAME SINGLE HOUSE, LOT 2 DATE 11/19/2007 SYSTEM NAME BASEMENT FL.,FAU-2 AREA FLOOR AREA 1,595 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE NEW BASEMENT FLR. NEW BASEMENT FLOOR 1 573 12,186 139 573 12,186 139 501 18,666 PAGE TOTAL 1 573 12;186 139 501 18,666 TOTAL 1 573 12,186 139 501 18,666 EnergyPro ' By EnergySoft User Number: User Job Number: P061676R Page:19 of 35 ROOM LOAD SUMMARY PROJECT NAME SINGLE HOUSE, LOT 2 DATE 11/19/2007 SYSTEM NAME MAIN FLOOR, FAU-1 AREA FLOOR AREA 628 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE NEW MAIN FLOOR NEW MAIN FLOOR 1 481 10,247 297 481 10,247 297 316 11,783 PAGE TOTAL 1 481 10,247 297 316 11,783 TOTAL 1 481 10,247 29711 316 11,783 EnergyPro By EnergySoft User Number: User Job Number: P061676R Page:20 of 35 ROOM LOAD SUMMARY PROJECT NAME SINGLE HOUSE, LOT 2 DATE 11/19/2007 SYSTEM NAME MAIN FLOOR, FAU-3 AREA FLOOR AREA 1,345 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT . CFM SENSIBLE LATENT CFM SENSIBLE NEW MAIN FLOOR NEW MAIN FLOOR 1 741 15,766 180 741 15,766 180 561 20,887 PAGE TOTAL 1 741 15,766 180 561 20,887 TOTAL 1 741 15,766 18011 561 20,887 EnergyPro. By EnergySoft User Number: User . Job Number: P061676R Page:21 of 35 ROOM LOAD SUMMARY PROJECT NAME SINGLE HOUSE, LOT 2 DATE 11/19/2007 SYSTEM NAME MAIN FLOOR, FAU-4 AREA FLOOR AREA 2,466 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE NEW MAIN FLOOR NEW MAIN FLOOR 1 1,207 25,681 -4 1,207 25,681 -4 699 26,033 PAGE TOTAL 1 1,207 25,681 -4 699 26,033 TOTAL 1 1,207 25,681 -4 699 26,033 EnergyPro By EnergySoft User Number: User Job Number: P061676R Page:22 of 35 IROOM LOAD SUMMARY PROJECT NAME DATE SINGLE HOUSE, LOT 2 11/19/2007 SYSTEM NAME FLOOR AREA FAM AREA 1,930 EnergyPro By EnergySoft User Number: User Job Number: P061676R Pege:23 of 35 ROOM HEATING PEAK LOADS Rroject Title Date (SINGLE HOUSE, LOT 2 11i19/2007 Room Information Design Conditions !Room Name NEW BASEMENT Time of Peak Jan 12 am Floor Area FL0595 Outdoor Dry Bulb Temperature 260E Indoor Dry Bulb Temperature 70°F ; Conduction Area U -Value 30.0 X 1 X x x X X x X x x X X x x X X X X X X x X X X X X X X X X X x x X X X X x x 0.1020 x X X x x x x X x x x x x x X X X X X x X X X x X X X X X x X X X x X X X X x 15.0 0.3400 391.5 0.0688 21.0 0.1020 15.0 0.3400 400.5 0.0688 120.5 0.1020 118.0 0.3400 251 1 0_0-6$8 489.6 0.0688 _perimeter = 205.8 0.7300 items shown with an asterisk (') denote conduction through an interior surface to another room. Infiltration: [ 1.00 x 1.064 x 1 595 x 9.00 x 0.396 / 6] x Schedule Air Sensible Area Ceiling Height ACH Fraction AT OF Page Total 44 OT Btu/hr 135' i_ 224, 1,185{ 94i 2241 ' 1,2121 541{ 1 7651 r -may 760; 1,482' L 6,610; = I i = I I = 1 I i = 1 i _ I 1� = 1 = 1 i _ it i 14,2331 4,4331 TOTAL HOURLY HEAT LOSS FOR ROOM 18,666 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 24 of 35 ROOM HEATING PEAK LOADS Title Date lRoom Information Design Conditions j Room Name NEW MAIN FLOOR Time of Peak Jan 12 am i `Floor Area 628 Outdoor Dry Bulb Temperature 26OFj Indoor Dry Bulb Temperature 70°F Conduction Area U -Value 628.0 X x x x x x x x X x x x X X x x x x x x x X x X x x x X X X X x x x x x x X x 0.0350 x X x x X x x x X x x X x x x x x x x x x x x x x X X x x x X x X x x X x x X 197.0 0.1020 68.0 0.3400 265.0 0.1020 248.0 0.1020 8.0 0.3400 232.0 0.1020 24.0 0.3400 perimeter = 104.2 Q -73-M Items shown with an asterisk (') denote conduction through an interior surface to another room. Infiltration: [ 1.001X 1.064 x 628 x 10.00 x 0.356 / 60] x Schedule Air Sensible Area Ceiling Height ACH Fraction OT OF Page Total 44 ,L^),T Btu/hr 9671, 8841 _ 1,189 1.,1131 120; = i 1,0411 359' 3,347; c I� _ c I _ 10,038; iL 1,745 TOTAL HOURLY HEAT LOSS FOR ROOM 11,783 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 25 of 35 ROOM HEATING PEAK LOADS Project Title Ill/19/2007 DateSINGLE HOUSE LOT 2 Room Information Design Conditions Room Name NEW MAIN FLOOR Time of Peak Jan 12 am Floor Area 1,345 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value nT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17,149 Infiltration: [ 1.001 x 1.064 x 1 345 x 10.00 x 0.356 / 60] x 44 = 3,738 Schedule Air Sensible Area Ceiling Height ACH ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,887 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 26 of 35 1,345.0 X X X X X x x X x x X X x X X X X X X X x X x X X x x X x X X X X X X X x X X 0.0350 X x X X x X x X x x x X X x X X X X X X x X X x X X X x x x X x X X X x X X x 44 = = = = = - = = = = = = = = = = = = = = = = = = = = = = = = = = — = = = — = 192.0 0.1020 44 76.0 0.3400 44 255.0 0.1020 44 357.0 0.1020 44 845.0 0.1020 44 55.0 0.3400 44 _perimeter= 178.0 0.7300 44 I I Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17,149 Infiltration: [ 1.001 x 1.064 x 1 345 x 10.00 x 0.356 / 60] x 44 = 3,738 Schedule Air Sensible Area Ceiling Height ACH ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,887 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 26 of 35 ROOM HEATING PEAK LOADS !Project Title Date }SINGLE HOUSE, LOT 2 111/19/2007 Room Name NEW MAIN FLOOR Time of Peak Jan 12 am! IFloor Area 2,466 Outdoor Dry Bulb Temperature 26OF I Indoor Dry Bulb Temperature 70 OF Conduction surface Area Area x x x x x X X X x X X X X X X x x x x x x x x x x x x x x x x x x x x x x x X U -Value X x x x x x x X X x x X X X X x x x x x x x x x x x x x x x x x x X x x x X X AT of = = = = = i = j- = I = = = = _ = = = = = - _ = = = = = = = = = = = = = Btu/hr R-30 Roof(R.30.2x12.16) 2,386.0 0.0350 44 3,674j R-13 Wall 149.0 0.1020 44 6691 Double-Non_Metal_CJear_(.5a 236.0 0.3400 44 3,531 R-13 Wall 230.0 0.1020 44 1,032 _13-1_3_Wa!! 528.0 0.1020 44 2,370, Double Non Metal Clear f5) 92.0 0.3400 44 1,376. R-13 Wall 126.2 0.1020 44 5671 Double Non Metal Clear U 69.8 0.3400 44 1,0431 _Slab=On_Grade perimeter = 153.1 7300 44 4,918 _� —1 `i _ ' ! ! 1 J Items shown with an asterisk (') denote conduction through an interior Infiltration: [ 1 1.0o x 1.064 X2,466 Schedule Air Sensible Fraction to another room. x 10.00 Ceiling Height 0.356 / 60] ACH Page Total: 44 DT 19,1801 6,854 TOTAL HOURLY HEAT LOSS FOR ROOM 26,033 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 27 of 35 ROOM HEATING PEAK LOADS --71 Project Title 11/19/2007 (Room Information Design Conditions I Room Name NEW MAIN FLOOR Time of Peak Jan 12 am [Floor Area 962 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area 74.0 20.0 308.0 332.0 43.0 214.0 41.0 perimeter = 95.8 U -Value OT of Btu/hr 0.0350 X 44 = 1141 0.1020 X 44 901 0.1020 X 44 - 1,3 0.1020 X 44 1,490 0.3400 X 44 = 643j 0.1020 X 44 = I 9601 0.3400 x 44 _ 6131 0.7300 X 44 3 077 X X = I X = x = x c x = X = x = _ X = 1 ~ X = x = x = X = x _ X = ' x = i X X = �� X = X = x X = X = X X = X X = X = X = x Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: E::::! 8,33 01 Infiltration: CSchedul1.0e x Air Sensible x Area Ceiling X Ceiling HelgOtx A H356 / 60� x OT 44 = L 6 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,044 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 28 of 35 ROOM HEATING PEAK LOADS project Title Date ISINGLE HOUSE, LOT 2 11/19/2007 Room Information Design Conditions Room Name LOFT SPACE Time of Peak Jan 12 am Floor Area 968 Outdoor Dry Bulb Temperature 26OF I ;Indoor Dry Bulb Temperature 70°F Conduction Area 968.0 327.2 16.8 244.0 100.0 704.4 30.0 694.7 39.$ LI -Value 0.0350 0.1020 0.3400 0.1020 0.3400 0.1020 0.3400 0.1020 —0-3 400 AT OF Btu/hr i 1,491 1,469 2511 1,095 1,4961 3,162` 449; 3.118! = 595 _ _ = I = 1 _ = _ 1 x x x x = x x = i x x = i x x = _ Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13,124 1 Infiltration: I .001X 1.064 x 968 x 8.60 x 0.414 / 60] x 44 = I 2,690] Schedule Air Sensible Area Calling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,814 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page 29 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title iSINGLE HOUSE. LOT 2 (Room Information Design Conditions I Room Name: NEW BASEMENT FLOOR Outdoor Dry Bulb Temperature: 1110F ` Floor Area: 1,595 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F i Opaque Surfaces 8" Solid Grout CMU Wall W/ R-13 RIGID R-13 Wall 8" Solid Grout CMU Wall W/ R-13 RIGID R-13 Wall 8" Solid Grout CMU Wall W/ R-13 RIGID 8" Solid Grout CMU Wall W/ R-13 RIGID Orientation Area 30.0 X 391.5 X 21.0 X 400.5 X 120.5 X 251.11 X 489.6 X 23.0 x 26.0 x LN) X 16.8+ x 16.8= X Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration WIN WIN Lrdll►i U -Factor X X X X X X x x X X X X CLTD 1 = = 1 = = = = = = 0.1020 33.0 0.0688 33.0 0.1020 33.0 0.0688 33.0 0.1020 23.0 0.0688 23.0 0.0688 26.0 32.9 LN) 0.0x 16.8+ 118.0X 16.8= S 0.0 16.8 0.0 16.9 Page Total Orientation Shaded Area 1 x X Ix X x X X x x GLF + + + + + + + + + Unshaded Area x x xI x X X X X x Page GLF 32.9= = = I= (W) 0.0x 16.8+ 15.0x1 (E) 0.0 16.8 15.0 32.9 LN) 0.0x 16.8+ 118.0X 16.8= S 0.0 16.8 0.0 16.9 Total Btu/hr Btu/hr Internal Gain Btu/hr Occupants X Occupants X 230 BtUh/OCC. 4601 Equipment1i 1x Dwelling Units x 1 600 Watts/sgft = 1,600 Infiltration: 1.064 x 0.94 x 101.06 x 36 = 3 627_.) Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,1861 Latent Gain Btu/hr Occupantsr72 X Occupants x 200 Btuh/OCC. = 400 Infiltration: 4,771 x 0.94 x 101.06 x 0.00058 = -26J1 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 139 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 30 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date SINGLE HOUSE, LOT 2 111/19/2007 Room Information Design Conditions Room Name: NEW MAIN FLOOR Outdoor Dry Bulb Temperature: 111°F ;Floor Area: 628 sf Outdoor Web Bulb Temperature: 73°F j !Indoor Dry Bulb Temperature: 75OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area x x x X X X X X X X X x U -Factor x x x x X X X X X X X X CLTD 1 = = = = = = = = 628.0 0.0350 56.0 197.0 0.10201 33.0 265.0 0.1020 33.0 248.0 0.1020 23.0 232.0 0.1020 26.0 16.8 8.0 16.8 (S) 0.0X 16.8+ 24.0X 16.9 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration F'age Total Page Total Internal Gain Occupants 2 X Occupants X 230 Btuh/occ. = qui ment 1 X Dwelling Units X 1,600J Watts/sgft = Btu/hr Btu/hr 2,236 0 135 406 _ 2,776 Btu/hr 460 1 1,600! Infiltration: 1.064 x 0.94 x 39.79 x 36 = 1,428 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,247 Latent Gain Occupants I E--21 X Occupants X 200 Btuh/occ. _ Btu/hr I 400 Infiltration: 4,771 x 0.94 x 39.79 x 0.00058 = -103 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 297 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:31 of 35 Orientation Shaded Area X x X x x X X x X X GLF + + + + + + + + +X I +I Unshaded Area 68.0 X x X x X X X X X GLF (W) 0.0 16.8 32.9 (E) 0.0 16.8 0.0 32.9 N 0.0 16.8 8.0 16.8 (S) 0.0X 16.8+ 24.0X 16.9 i F-1 Page Total Internal Gain Occupants 2 X Occupants X 230 Btuh/occ. = qui ment 1 X Dwelling Units X 1,600J Watts/sgft = Btu/hr Btu/hr 2,236 0 135 406 _ 2,776 Btu/hr 460 1 1,600! Infiltration: 1.064 x 0.94 x 39.79 x 36 = 1,428 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,247 Latent Gain Occupants I E--21 X Occupants X 200 Btuh/occ. _ Btu/hr I 400 Infiltration: 4,771 x 0.94 x 39.79 x 0.00058 = -103 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 297 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:31 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title SINGLE HOUSE. LOT Room Name: Floor Area: i Indoor Dry Bulb Temperature: NEW MAIN FLOOR Outdoor Dry Bulb Temperature: 1,345 sf Outdoor Web Bulb Temperature: 75 of Outdoor Daily Range: Orientation Area U -Factor CLTD 1 N) 1,345.0 X 0.0350 X 56.0 = (W) 192.0 X 0.1020 X 33.0 = L) 255.0 X 0.1020 X 33.0 = (� 357.0 X 0.1020 X 23.0 = (S) 845.0 X 0.1020 X 26.0 = x x = x x = x x = x x = x x = x x = x x = Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration LUTIN, rage I otal Orientation Shaded Area X x X X X X x x GLF + + + + + + + + Unshaded Area X x X X X X x X Page GLF 32.9= 32.9= = = = = = = W 0.0X 16.8+ 76.0X L 0.0x 16.8+ 0.0x (N 0.0 16.8 0.0 16.8 S 0.0x 16.8+ 55.0X 16.9= 400 Infiltration: 4,771 x 0.94 x 85.22 x 0.00058 = -220 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 180 Total 111-F 730F 340F I Btu/hr Btu/hr Internal Gain Btu/hr Occupants 2X Occupants x 230 Btuh/occ. = 460 'Equipment 1 X Dwelling Units X 1,6001 Watts/Sgft = 1 6001 Infiltration: 1.064 x 0.94 x 85.22 x 36 = i 3,058 Air Sensible CFM ELA 4W TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,7 Latent Gain Btu/hr Occupants IF 2] X Occupants x 200 Btuh/occ. = 400 Infiltration: 4,771 x 0.94 x 85.22 x 0.00058 = -220 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 180 ` EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 32 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date J 'SINGLE HOUSE. LOT 2 111/19/2007 Room Name: NEW MAIN FLOOR Outdoor Dry Bulb Temperature: 111" F Floor Area: 2,466 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F ue surraces R-13 R-13 Wall Orientation Area X X X X X x x X X x x X U -Factor X X X X X x X X X X X x CLTD 1 56.0 = = = = = = = = = = (� 2,386.0 0.0350 (M 149.0 0.1020 33.0 (E) 230.0 0.1020 33.0 (� 528.0 0.1020 23.0 (S) 126.2 0.1020 26.0 92.0X 16.8= 1,550 S) 0.0 16.8 69.8I 16.9 1,179 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration r� Page 1 otal Btu/hr Orientation Shaded Area X x X x X x X X x GLF + + + + + + + + + Unshaded Area X X x x x x X X x Page GLF = = = -1 =L Btu/hr W) 0.0 16.8 236.0 32.9 7,7591. (E) 0.0x 16.8+ 0.0x 32.9= 0 (N) 0.0x 16.8+ 92.0X 16.8= 1,550 S) 0.0 16.8 69.8I 16.9 1,179 I Total 1o,ass Internal Gain Btu/hr Occupants 2 X Occupants X 230 Btuh/ocC. = 460 Equipment 1 X Dwelling Units X 1,600] Watts/sqft = 1,6001 Infiltration: 1.064 X 0.94 x 156.25 x36 = L 5 607 15 607 j Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25681 Latent Gain Btu/hr Occupants 0 X Occupants X 200 Btuh/oCC. = 4001 Infiltration: 4,771 x 0.94 x 156.25 x 0.00058 = -404 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM -a EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page:33 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date {SINGLE HOUSE, LOT 2 111/19/2007 Room Information Design Conditions ;Room Name: NEW MAIN FLOOR Outdoor Dry Bulb Temperature: 111°F Floor Area: 962 sf Outdoor Web Bulb Temperature: 73°F I Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F j opaque burtaces IR -3r 0 Roof(R.30.2A2.16) R-13 Wall R-13 Wall R-13 Wall R-13 Wall Orientation Area X X X X X X x X X X X X U -Factor X X X X X x x X X XI X X CLTD 1 = = = = = = = (N) 74.0 0.0350 56.0 (W) 20.0 0.1020 33.0 (E) 308.0 0.1020 33.0 (� 332.0 0.1020 23.0 �(S) 214.0 0.1020 26.0 242 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration (WINDOWS I rage I otal Btu/hr Shaded Unshaded Orientation Area GLF Area GLF Btu/hr (W) 0.0x 16.8+ 0.0x 32.9= 0 (E) 0.0 X 16.8 + 0.0 x 32.9 = 0 (N) 0.0 X 16.8 + 43.0 X 16.8 = I 724. (S) 0.0x 16.8+ -41.0 X 16.9= 693 x + x X + X I= X + x X + X = X + X X + X X + X Page Total 1,4181 Internal Gain Btu/hr Occupants P 2 x Occupants x 230 Btuh/occ. = P 460 Equipment 1 X Dwelling Units x 1 600 Watts/sqft = 1 600 Infiltration: 1.064 x 0.94 x 60.95 x 36 = 8 Air Sensible CFM ELA �W TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,2611 Latent Gain Btu/hr Occupants L_.J X Occupants x 200 Btuh/occ. = 400 Infiltration: 4,771 x 0.94 x 60.95 x 0.00058 = -158 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 242 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 34 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY (Project Title Date I (SINGLE [Room HOUSE, LOT 2 11/19/2007 ' om Information Design- Conditions I Room Name: LOFT SPACE Outdoor Dry Bulb Temperature: 111OF Floor Area: 968 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-30 Roof(R.30.2x12.16 N 968.0 X 0.0350 X 56.01 = 1,897 R-13 Wall (W) 327.2 X 0.10201 X 33.0 = 1,1021 R-13 Wall (E) 244.0 X 0.10201 X 33.0 = 821 R-13 Wall (� 704.4 X 0.1020 X 23.0 = 1,653' R-13 Wall 694.7 X 0.1020 X 26.0 = 1,842 X X x X = X X = X X =i X X = X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 7,315. 1. Cooling Load Temperature Difference (CLTD) Fenestration Shaded Unshaded Orientation Area GLF Area GLF Btu/hr (-W) 0.0 x 16.8 + 16.8 x 32.9 = 551 (E 0.0 X 16.8 + 100.0 x 32.9 = 3,288 (N) 0.0 X 16.8 + 30.0 X 16.8 = 505 (� 0.0 x 16.8 + 39.8 X 16.9 = 672 X + X X + X = X + X = X + X X + X X + X = X + X = Page Total 5,o1s Internal Gain Btu/hr Occupants 122 X Occupants X 230 Btuh/OCC. = 460 Equipment 1 X Dwelling Units X 1 600 Watts/sqft = 1,6001 Infiltration: 1.064 x 0.94 x 61.33 x 36' = 2,201 Air Sensible CFM ELA Z�'T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,592 Latent Gain Btu/hr Occupants��2 X Occupants X 200 I Btuh/occ. = 400 Infiltration: 4,771 x 0.94 x 61.33 x 0.00058 = -1591 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 241 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: P061676R Page: 35 of 35 DATA SHEETS ProntaLankless Gas Water Heater 10 Year Limited Warranty on Heat Exchanger* 3 Year Limited Warranty on Parts* (residential applications) • Continuous hot water • Energy saving design • Compact, space saving design • Intelligent electronic controls designed to increase energy efficiency and safety • Self diagnostic program • Digital display shows temperature setting and maintenance codes • Exclusive oxygen depletion sensor • Exclusive film wrap overheat limiter • Built-in electric blower • Indoor units use Category III stainless steel vent • Pressure relief valve included • Supplied with a 120 volt power cord • Low NOx emissions meet SCAQMD rule 1121 requirements See Residential Warranty Information Brochure for complete warranty information. m"^"• How It Works 1 Open hot water tap. 2 Cold water enters unit. 3 Fan turns on. 4 Gas enters unit. 5 Burner turns on. 6 Cold water is heated in the heat exchanger. 7 Hot water is mixed with bypassed cold water for final outlet temperature. ISM sroe-ww sou Indoor models vent horizontally through side wall This water heater has a built-in electric blower to force exhaust gas to the outside. Category III stainless steel vent is (UL1738 certified) required in order to avoid damage from possible condensation. Type "B vents are not permitted. A Rheem stainless steel vent adaptor (or equivalent) is required for vent connection for both models. • Factory set maximum temperature is 120° F. • For installations above 3,280 feet the connector on PC board must be replaced. Refer to Rheem price list or consult factory for details. • Consult factory for information on sizing the application. These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, BOCA Code and all state energy efficiency performance criteria for energy consuming appliances. Before purchasing this appliance, read important energy cost and efficiency information available from your supplier. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. There is no equal:" Printed in U.SA 03!04 WP Fonn No.101-4 Rev.1 Rheem Water Heaters • 101 Bell Road • Montgomery, AL 36117-4305.800-621-5622 • sales@rheem.com • www.rheem.com RTG-42PVN 31,500 1000 to Indoor 2.4 3/4 1/2 22-1/4 13-3/4 5-1/8 3 35 .81 (NAT. GAS) 118,000 140` F RTG-42PVP 31,500 Indoor 100° to 2.4 3/4 1/2 22-1/4 13-3/4 5-1/8 3 35 (LP GAS) 118,000 140' F .81 RTG-74PVN 19,000 Indoor 100° to 4.2 3/4 3/4 25-3/8 14-5/8 10-7/8 4 55 (NAT. GAS) 199,000 140° F .82 RTG-74PVP (LP GAS) 19,000 199,000 Indoor 1000 to 1400 F 4.2 3/4 3/4 25-3/8 14-5/8 10-7/8 4 55 .82 RTG. GAS) (NAT. GAS - 199 19,,000 Outdoor to 100' F 140 F000 25-3/8 4.2 3/4 3/4 14-5/8 10-7/8 WA 55 .82 RTG-74XP 19,000- ' Outdoor 100'to 4.2 3/4 3/4 25-3/8 14-5/8 10-7/8 N/A 55 (LP GAS) 199,000 140 F .82 ISM sroe-ww sou Indoor models vent horizontally through side wall This water heater has a built-in electric blower to force exhaust gas to the outside. Category III stainless steel vent is (UL1738 certified) required in order to avoid damage from possible condensation. Type "B vents are not permitted. A Rheem stainless steel vent adaptor (or equivalent) is required for vent connection for both models. • Factory set maximum temperature is 120° F. • For installations above 3,280 feet the connector on PC board must be replaced. Refer to Rheem price list or consult factory for details. • Consult factory for information on sizing the application. These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, BOCA Code and all state energy efficiency performance criteria for energy consuming appliances. Before purchasing this appliance, read important energy cost and efficiency information available from your supplier. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. There is no equal:" Printed in U.SA 03!04 WP Fonn No.101-4 Rev.1 Rheem Water Heaters • 101 Bell Road • Montgomery, AL 36117-4305.800-621-5622 • sales@rheem.com • www.rheem.com Product Data HEATING 8 COOLING Performance TM 13 38TXA (60 Hz) Air Conditioner with Puron° Refrigerant Sizes 024 thru 060 Copyri„hl 2004 Carrier Corporation Carrier's PerformanceT” 13 Air Conditioners with Puron© refrigerant provide a collection of features unmatched by any other family of equipment. The 38TXA has been designed utilizing Carrier's Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth's ozone layer. Carrier's PerformanceTM 13 system with Puron refrigerant meets the Energy Star~J guidelines for energy efficiency. FEATURES Puron Environmentally Sound Refrigerant — Is Carrier's exclusive refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. The most important advantage of Puron refrigerant is that it has not been banned in future air conditioning systems as the traditional refrigerant R-22 has been. Puron refrigerant is in service in thousands of systems providing highly reliable, environmentally sound performance. Carrier's Infinity® Con trots — These industry-leading controls, when installed with Carrier's Ideal HurnidityTM variable - speed furnaces or fan coils, provide the homeowner with: –Unparalleled control of temperan:rc,' - humidity, indoor air quality, and zoning –unprecedented ease of use –simple operation through on-screen, text - based service reminders Optional remote access through telephone orIntemet is also available when combined with a remote connectivity kit. WeatherArmorTM III Protection Package —This three-part protection system begins with the galvanized steel cabinet. Once coated with a layer of zinc phosphate, a modified polyester powder • coating is then applied and baked on, r providing each unit with a hard, s: tooth finish that will last for many years. Additionally, the coil protector, made of a coated steel wire grid with vertical 3/8 in. spacing, is designed to help protect the coil from inclement weather, vandalism and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil cleaning. Form 38TXA-10PD Combination . ratings FACTORY- SEER SUPPLIED Carrier' `UNrT INDOOR TOT. CAP. ENHANCE- Standard Pas Furnace or Accessorryy SIZE -SERIES UNIT BTUH MENT Rating AccessoryTDRt PuronTXvt EER CC5A/CD5AW030 CE3AA024 CE3AA030 CF5AA024 CK38AO24 CK38AO30 CKSA/CK5BA024 CKSA/CK5BA030 CK5A/CK58W024 CK5A/01<58W030 CK5PA024 CK5PA030 CKSPW024 CK5PWO30 F(A,B)4BN(F,C)Q24 F((A,B)))4448N F,C)030 F CN 024 FC-4CNF030 FE4ANF002 _. FE4AMF003. FF I DNA024 . FF1DNA030 _ FFIDNE024 - _ FFIDNE030-. F03AAA024 - FK4DNFQ91 FK4DNF002 FK4DNF003 FV4BNF002 - FV4BNF003 FX48NF030 ' CC5A/CO5AW024 CC$A/CO5AW030 CE3AA024 CE3AA030 ' 024.34 CK38AO24 CK38AO30 CK5A/CK58A024 CK5A/CK5BA030- CK5A/CK5B W024 CK5A/CK58W030. CK5PA024 CK5PA030 • CKSPW024 CK5PW030 CC5A/C05AW024 CC5AIC05AW030 CE3AA024 ' CE3AA030 CK3BA024 CK38AO30 -CKSA/CK5BA024 CK5A/CK58AO30 . CK5A/CK5BW024 CKSA/CK5BW030 CK5PA024 CK5PA030 CK5PWO24 CK5PW030 CE3AA024 CE3AA030' CK3BA024 CK3BA030 CKSA/CK5 B WO24 CK5A/CK58W,30 CK5PW024 CE3AA024 CE3AA030 See notes on pg. 22. 8 23,000 NONE - 13.00. 13.00 11.25 22,800 NONE' - 12.50 12.50 11.15 22,800 NONE - 12.50 12.50 11.15 23,000 NONE - 13.00. 13.00 11.25 22,800 NONE - 12.50 12.50. 11.25 23,000 NONE - 13.00 13.00 11.35 '22,800 NONE - .12.50 12.50 11.13 22,800 NONE - 12.50. 12.50 11.30 23,000 NONE - 13.00 13.00 11.35 22;800 NONE - 12.50 12.50 11.30 23,000 NONE - 13.00 13.00 11.35 .22,800 NONE - .12.50 . 12.50 11.30 23,000 NONE .. - " 13.00 13.00 11.05 22,800 TXV- - 12.50 - 11.30- 1.30_23,000 23,000. TXV - 13.00 - 11.35 22,800 TXV - 12.50 _ - 11.30 23,000 TXV - 13.00 - 11.35. - 23,000 TDR 13.00 - 13.00 11.40 ' '"' 23,400 TOR.- 13.00 - 13.00 11.50 23,000 TDR&TXV. "... 13.00' - - '11.40 23,400 TDR&TXV 13.00 - - 1'1_55. 23,600 TDR&TXV 14:50 - - 12.85 23,600. TDR&TXV 14.50. - _ t 13.00 23,000 TOR' 12.50 - =12.50 11.2, 23,400• TDR ' 13.00 13.00 11.35 - 23,000 '.. TDR&TXV 12.50 - - 11.20 " 23,400 TDR&TXV 13.00 ' - - 11.35. 22,000-. NONE - .12.50. 12.50 .11.00 ' •23,400 TDR&TXV .14.00 - - 12.65 23,600 TDR&TXV. 14.50 - - 12.85 - 23,600 TDR&TXV 14.50 - - 13.00 " 23,600 TDR&TXV ..14.50 - - - 12.85 - 23,600 TDR&TXV 14.50 - 13.00 •. 23,400 TDR4TXV ' ' 13.00 • - - 11.70 I •E • 22,400 _ TDR14.00 - •14.00 12.15 22,800 TDR 14.00 - 14.00' .42.35 .22,400 TOR 14.00 _ - 14.00 12.20 22,800 TDR 14.00 - 14100 12.35 '22,400 TDR 14.00 - - -14.00 1225 22,800 TOR ' 14.00.• - •14.00 12.45 22,400 TOR 14.09 - . 14.00' 12.50 _ 22,800 TDR 14.00 - - 14:00 12.55' 22,400 TDR .14.00 14.00 12.35 22,800 TDR .. 14.00 - 14.00 12.45 22,400 TDR 14.00 14.00 -12.35 ' 22,800 TDR 14.00 = 14.00 12,50 . 22,400 TDR&TXV 14.00 - - 12.25 22,600 TDR&TXV 14.00 - - 12.35 22,400 TDR&TXV. •14.00 - ._12.25 22,800 TDR&TXV 14,00 - = 12.40 �DIft 22,400 TOR, 14.00 - .--14.00• 12.25 22,800 TDR._ 14.00' - 12.50 22,400 TDR.. 14.00: _14.00 14.00.- 12.35 - 22,800 TDR 14.00 - 14.00 '12.50 22,400 TDR14.00 - - 14.00 12.35 22,800 TDR 14.00" - 14.00- 12;55 22,400TDR 14.00 - -14.00 12.60 22,800 TDR .14.00 -14.00 12.65 22,400 TDR _ 14.00'.. ,- _ _ 14.00-' 12.45 22,800 TDR 14,00: - 14.00 12.55 22,400 TDR - -' 14.00 . - - - 14.00 12.45. 22,800 TDR -. 1.4.00 - .14:00 _12.60- . 22,400 TDR&TXV' . __ 14.00. - - -- 12.35- 22,800 TDR&TXV. 14.00- 12.50. 22,400 TDR&TXV 14:00 -- 12.40' 22,800 TDR&TXV 14.00 ' ' - 12.55 22,400 TDR 14.00. _. - _14.00-'. 1225 22,800 TDR 14.00." - 14.00 12.40; 22,400 TDR 14.00 .. - -7 14:0012.20 22,800 TOR14.00 - - - 14.001 2.10 22,400 TDR "' 14.00 - - 14.00 . X2.55- 22,800 TDR 14:00_ - - _ .14.00 12.60 22,400 TDR 14.00 - _ 14.00 12.35 22,800 TDR 14.00 - - 14.0012.55 22,400 TDR&TXV . 14.00 - - -12.30 22,800 TDR&TXV 14.00 - _ - 12.45 22,400 TDR 14.00 - 14.00 12.25 22,800 TDR 14.00 - 14.00 1250 _ ....... . i ,gyp ' a. tag°y ��a `j,•,. (P+. pR {] / _ .6i � c In''. +�$ 0 t{ 6' ll.s'� J tl =.... SEER.. . �', '`SlJk?.PLI,ED'st: •.;.tcr ..,v.•;: ":;�'� nti �Yn..�Ci f[l0fe,•.'. ,>i;; �•ai .§ . '=G8s;F4rnace`0� %[ Acoassory fOT. CAP.. ENHANCEr. `.:,}",'Standard'';;. r PuronTXY#' '.'EER .` UNIT INDOOR' BT UH� MENT6::.: . ~ .Rating' ' Accessory:7DRf: 512E -SERIES " UNIT':: �i h ! . ; ...Y :•,_.:.:.... v.:; • 14.00 ::..: •' - 12.30 709 14,00'° - 1400 12.55 CE3AA024 22 800 7OR 14,00 CE3AA030 KGOL�;S 1AMYPQAQa74,JI,A..:5 sPi +'•.p,as�FCo yr"E �,v:,,,• TOR 14.00 - 14,00 12.20 CE3AA024 22,400 22^800 TDR • 14.00 14,00 12.45 , i CE3AA,030 ON , _ % 12.15 CC5A/CD5AA024c TDR ' TDR 14.00 14.00 14.00 - 14,00 •14,00 12.40 12.25 22,400 C5A/CO5AA030 CC5A/C05AW024 22.400 TOR TDR 14.00 14.00 _ 1400 12.40 12.25 CC5AlCD5AW030 1 22800 22 400 TDR 14.00 - 14.00 14.00 . 12.45 CE3AA024' 22,800 TOR TDR:" 14.00 1.4.00: - 14.00 12.55 CK3 AO24 22,400. 22,800 . TDR' , .. ': ? 14:00' .:. 14.00 ' 1:4.00 12.60 12.35 CK38A030 jCKWCK58A024 22,400 ... TDR; • .:::TDA`.:;,,,.:, 14.00:'...:. ':+ _ . ',;' :. '._. �. 14.00.. .ri2.45:. ,. ! CK5A/CKSBA030 - 22,800:. .. 22,400' `:. :' TDR ', ':" .:•.14.00; ::.';:14.00;,'.::. - 1`4,00 `' ' :'; ' '.'-.. 14.00.. t `' 12;40' , y CKSAICK58W024 .. GKSA/CK5BW030... 22,800'. TDR .;.:' ' 'TDR&TXV ::' '::'.'':14:00;:•' -: ....~i400..,s.. ..: .r .'.::;:=- 12,30 1 CK5PA024'. 22,400.. 22,800 70R&TXV, '`' '- • :.14:00': :. , `.: ' .. - 12.40 12.30 CK5PR030•. CK5PW024 22,400 TDR&TXV .:.., ° :: 14.00 ..'... ": 14.00' - _ :_, ' .:. - 12.45 j CKSPW030` 22,800' TDR&TXV`' x.» - 4.00 ' ...12.20"-:-TOR_"­"-'14:00' y CCSACD5AW024'.: CC5A/CDSAW030 22,400 22,800 TOR 14.00 - 14.00 14.00 12.35 12.20 II CE3AA024 22,400 22,600 TDR TDR 14.00 14.00 14.00 12.45 12.50 f CE3AA030 I CK3BA024 22,400 TDR TDR 14.00 14.00 - •14.00 - 14,00 .12.55 024 3=> CK3BA030 . CK5A/CK513W024 22;800 22,400. : T.DR::.,' 14.00 , ' - 14,00 - : 14.00 12.35 12.50 CKSA/CK58W030 22,800 , . ' 22,400 TDR '.'': TDXV.::• R&T 14,00. ':;::.14.00 " 12.30 CKSPW024. CK5PW030 22,800 TDR&TXV 14.00' - 12.40 r •' " 14 .00 14.00 14.00 1400 12.25 12,40 1 CC5A/CD5AW024 22,400' TDA` I [ CC5A/CO5AW030 22,800 22,400 TDR TOR 14.00 1400 12.25 CE3AA024 CE3AA030 22,800 TDR 14.00 - 14.00 1400 12.45 12.50 CK3BA024 22,400 22,800 TDR 14.00 14.00 _ 14.00 12.55 CK38AO33 CK5A/CK5BW024 22,400 .TDR TDR 14,00 _ 14;00 14.00. 12.40 12.50 CK5A1CK58W030 . '• 22,800 ' 22,400 TDR " TDR&TXV: 14,00 ' , . 12.30 ` CK5PW024 CK5PW030.: 22,800 TDA&TXV•' .,::14.00' , 14.00 - - 12.45 , , .'' 22,400 'TDR-.. ' ' T4.00 ` CC5A/CD5AW024 . ."..;.. 14.00 14,00 12.25 12.40 CC5A/CO5AW030 22,800 22,400 TOR TDR 14.00 14.00 - - 1400 12.25 CE3AA024 CE3AA030 22,800 TOR 14.00 - 1400 14.00 12,50 12.55 CK38A024 22,400 22,800 TDR TDR 14.00 14,00 - . - 14:00 12.60 i CK38AO30 ' CK5A/CK5BW024 22,400 :. TOR 14.00'..: '!; _ = 14.00 14.00. 12.40 12,50 ' j CKSA/CKSSW030. 22,800 22,400 TDR,' ', TDR&TXVI .' .''}4.00. .' '14.00,';,. ::,, 12.30 ' f CK5PW024'' .,:'::..:. CK5PW030 . 22.800 TDR&TXV'' 14.00' }2.45 22,400 TOR. 12.20 12.45 CE3AA024 ': 14.00 - 14:00 14:00 CE3AA030 22,800 TDR 14.00 - 'CCSA/CD5AA036 29,000 NONE - 13.00 13.00 11.20 12.50 12.50 10,85 CC5A/CDSAA030 28,000 NONE - CC5A/CO5AW030 28,000 NONE - .12.50 12.50 10.85 13.00 11.20 CC5A/CO5AW036 29,000 NONE 13.00 I j •3,000 NONE - 12.50 12.50 11.00 CE3AA030 I CE3AA036 28,400 NONE - 12.50 12:50 11.10 11.15 I CF5AA036 28,400 NONE - - 12,50 12:50 1 28,000 NONE - 12.50, 12:50 11.95 CK36A030 1 CK38AO36 29,006 NONE - 13.00 13.00 11.25 12.50 12,50 10.95 l CK5A/CK58A030 28,000 NONE CK5A/CK5BA036. 29,000 NONE '13.00 13.00 11.25 11.25 030-33 (j - CK5A/CK587036 29,000 NONE :13,00 13.00 NONE12.50'. 12.50 10.95 CK5A/CKSBW030 26,000 . .NONE1.25 CI<5A/CK5BW036 29,000 NONE "13.00 13.00 1 0.95 4 TXV 12.50 CKSPA030 28,000 1125 29,000 TXV - 13.00 CKSPA036 11,25 CK51TO36 29,000 TXV , }3.00, : 10.95 CK5PYV030 I 26,000 TXV' .:12.50 - - CKS?4V036" 23,000 TXV - :13,00 . " : - 11,25 t 'A,3))4�A,6))NjF,C 030 23,600 ,'TDR ' : 12.50:-"'.--: ...::;.` ?''-- 12.50 11.10. 29,000 TDR 12:50 = :` : : ' `. 12.50 10.95 . F�A,B)4,A,8)N(F,C;G36 LFEAANF002 27 000 TDR&TXV 13.50 12.05 See notes on P9•'2• ; . 9 s Combination ratings continued 030-33 CC5A/CD5AA036 29,600 CC5A/CD5AW030 28,400 CE3AA030 29,000 CE3AA036 29,200 CK3BA030 28,40 CK33AO36 29,600 CK5A/CK5BA036 29,600 CK5A/CK5BT036 29,600 CK5A/CK5BW030 28,400 CK5PA036 29,600 CK5PT036 29,600 CK5PW030 28,400 WROMMIMM CC5A/CD5AW030 28,600 CC5A/C05AW036 29,600 CE3AA030 29,000 CE3AA036 29,200 CK3BA030 28,600 CK38AO36 29,600 CK5A/CK58W030 28,600 CK5A/CK5BW036 29,600 CK5PW030 28,600 CK5PW036 29,600 FACTORY- SUPPLIED SEER - 13.50 - 13.20 _ 13.20 13.50 -0 13.20. - 13:50 - 13.50 - 13.50 - 13.20 - _ - - - 13.50 - 14.00 - 13.50 - 13.50 - 13.20 - 14.00 - 13.20 - 14.00 - - - - 11.90 11.50 11.65 11.75 11.45 11.95 11.95 11.95 11.45 11.95 11.95 11.45 11.65 12.10 11.80 11.90 11.55 12.10 11.55 12.10 11.55 12.10 Carrier UNIT INDOOR TOT. CAP. ENHANCE- Standard Gas Furnace or Accessory AccessoryTDRt PuronTXV* EER SIZE -SERIES UNIT STUH MENT Rating 13.50 11.95 CE3AA036 CK3BA036 29,600 28,400 TDR TDR 13.50 13.00 - 13.00 11.45 CE3AA042 CK5A/CK5BW030 CK5A/CK5BW036 29,600 TDR 13.50 - 13.50 11.95 W45 CF5AA036 CK5PW030 28,400 TDR&TXV 13.00 13.50 - - - - 11.95 CK3BA036 CK5PW036 29,600 TDR&TXV 13.00 13.00 11.20 030-33 CC5A/CD5AA036 29,600 CC5A/CD5AW030 28,400 CE3AA030 29,000 CE3AA036 29,200 CK3BA030 28,40 CK33AO36 29,600 CK5A/CK5BA036 29,600 CK5A/CK5BT036 29,600 CK5A/CK5BW030 28,400 CK5PA036 29,600 CK5PT036 29,600 CK5PW030 28,400 WROMMIMM CC5A/CD5AW030 28,600 CC5A/C05AW036 29,600 CE3AA030 29,000 CE3AA036 29,200 CK3BA030 28,600 CK38AO36 29,600 CK5A/CK58W030 28,600 CK5A/CK5BW036 29,600 CK5PW030 28,600 CK5PW036 29,600 TDR TDR TDR TDR TDR TDR TDR TDR TDR TDR&TXV TDR&TXV TDR&TXV TDR TDR TDR TDR TDR TDR TDR TDR TDR&TXV TDR&TXV 13.50 13.20 13.20 13.50 13.20 13.50 13.50 13.50 13:20 13.50 13.50- 13.20 13.50 14.00 13.50 13.50 13.20 14.00 13.20 14.00 13.20 14.00 - 13.50 - 13.20 _ 13.20 13.50 -0 13.20. - 13:50 - 13.50 - 13.50 - 13.20 - _ - - - 13.50 - 14.00 - 13.50 - 13.50 - 13.20 - 14.00 - 13.20 - 14.00 - - - - 11.90 11.50 11.65 11.75 11.45 11.95 11.95 11.95 11.45 11.95 11.95 11.45 11.65 12.10 11.80 11.90 11.55 12.10 11.55 12.10 11.55 12.10 -CC5A/CD5AA036 35,000 NONE - 13.00 13.00 13.00 11.20 13.00 11.20 CC5A/CD5AA042 CC5A/CD5AW036 35,000 35,000 NONE - NONE - 13.00 13.00 11.20 CE3AA036 35,000 NONE - 12.50. 12.50 11.05 CE3AA042 35,000 NONE - 13.00 13.00 11.30 CF5AA036 35,000 NONE - 13.00 13.00 11.15 CK3BA036 35,000 NONE - 13.00 13.00 11.20 CK38AO42 35,000 NONE - 13.00 13.00 11.20 CK5A/CK5BA036 35,000 NONE - 13.00 13.00 11.20 CK5A/CK5BA042 35,000 NONE - 13.00 13.00 11.20 CK5A/CK5BT036 35,000 NONE - 13.00 13.00 11.20 CK5A/CK5BT042 35,000 NONE - 13.00 13.00 11.20 CK5A/CK5BW0.36 35,000 NONE - 13.00 13.00 11.20 CK5PA036 35,000 TXV - 13.00 - 11.20 CK5PA042 35,000 TXV - 13.00 - . 11.20 CK5PT038 35,000 TXV -. 13.00 - 11.20 CKSPT042 35,000 TXV - 13.00 - 11.20 CK5PW036 35,000 TXV - 13.00 - 11.20 F(Av%4(A,B)N(F,B,C)042 35,000 TDR 13.00 - 13.00 11.25 F(A, �4(A,B)N(F,C)036 35,000 TDR 12.50 _ 12_50 11.15 11.75 E4ANNF002 FE4ANF003 35,000 35,000 TDR&TXV 13.00 TDR&TXV 13.50 - - 12.05 FE4ANF005 36,000 TDR&TXV 14.00 - - 12.20 F03AAA036 35,000 NONE - 12.20 12.20 10.95 FK4 C,D NF002 35,000 TDR&TXV 13.00 - - 11.75 FK4 C,D NF003 35,000 TDR&TXV 13.50 - - 12.05 FK4 C,D NF005 36,000 TDR&TXV 14.00 - - 12.20 .036.33 FV4 A,B NF002 35,000 TDR&TXV 13.00 - - 11.75 FV4 A,B NF003 35,000 TDR&TXV 13.50 - - 12.05 FV4 A,B NF005 36,000 TDR&TXV 14.00 - - 12.20 FX4 A,B NF038 34,000 TDR&TXV 12.25 - - 10.95 FX4 A,B NF042 35,000 TDR&TXV 13.00 - - 11.20 eUri CC5A/CD5AA036 35,000 TDR 1.3.50 - 13.50 11.80 CE3AA036 35,000 TDR 13.20 - 13.20 11.70 CE3AA042 35,000 TDR 13.50 - 13,50 11.95 CK3BA036 35,000 TDR 13.50 - 13.50 11.90 CK5A/CK5BA036 35,000 TDR 13.50 - 13.50 11.90 CK5A/CK5BE042 35,000 TDR 13.50 - 13.50 12.00 CK5A/CKSBT036 35,000 TDR 13.50 - 13.50 11.90 CK5PA036 35,000 TDR&TXV 13.50 - - 11.90 CK5PE042 35,000 TDR&TXV 13.50. - - 12.00 CK5PT035 35,000 TDR&TXV 13.50 - - 11.90 CC5A/C05AA036 c 35,000 ' TDR 13.50 - 13.50 12.00 CC5A/C05AA042 35,000 TDR 14.00 - 14.00 12.15 CC5A/CD5AW036 35,000 TDR 13.50 - 13.50 12.00 CE3AA036 35,000 TDR 13.20 - 13.20 11.90 CE3AA042 . 35,000 TDR 14.00 - 14.00 12.15 CK3BA036 35,000 TDR 13.50 - 13.50 ' 12.10 CK3BA042 35,000 TDR 14.00 - 14.00 12.15 CKSA/CK5BA036 35,000 TDR 13.50 13.50 12.10 CK5A/CK5BA042 35,000 TDR 14.00 - 14.00 12.15 See notes on pg. 22. 11 Combination ratings continued SEER FACTORY- Carrier SUPPLIED • Standard Gas Furnace or Accesso INDOOR TOT. CAP. ENHANCEry UNIT BTUH MENT Rating AccessoryTORt PuronTX t EER UNIT Siz&SERIES 080 B.0 E D� U N C z;, t' • t U '';' ts 13.50 35,000 TDR 13.50 13.20 CC5A/C05AA042 35,000 TOR 13.20 CCSA/CD5AW036 35,000 TDR 13.00 - 13.00 CE3AA036 35,000 TDR 13.50 - 13.50 11.65 CE3AA042 35,000 TDR 13,20 - 13.20 11.60 CK3BA036 - 35,000 TDR 13.50 - 13.50 11.75 CK36A042 35,000 TOR' 13.50 13.50 11.75 CK5A/CK58A042 35,000 TOR 13.50 - 13.50 t t.7; CKSAJCK56T042 13,20 - 13.20 11.60 CKSAJCK5BW036 35,000 TOR - - , 1 7 CK5PA042 35,000 TOR&TXV 13.50 - - 1:75 CK5PT042 35.000 TDR&TXV 13.50 CK5PW036 35,000 .. TDR&TXV - � •,,t� 13.20 , - 13.50 CCSNCD5AA042 F 35,000 TDR 13.50 - 35,000 TOR 13.50 13.50 t ..75 GC5N3AA036 36 - 35,000 TDR 13.00 - 13.00 11'51: CE3AA036 _ ' 35;000 TOR 13.50 - 13.50 i t.4 ` CE3AA042 TOR 13.00 - 13.00 1145 CK3BA036 35,000 13.00 - 13.00 11'6` CK3BA042 35,000 TDR - X3.00 1t 6^ CK5A./CK5BA042 .35.000 TDR 13.00 - 13.00TOR 13.00 CK5A/CKSBT042 35,000 TDR 13.00 13.00 CKSA/CK5BW036 -35,000 13.00 - - 'CK5PA042 35,000 TOR&TXV - CKS?7042: 35,000 TDR&TXV' 13.00 CK5PW036 35,000 TDR&TXV 13.00 - t - 1 '� oL . •Yt w Stii 036.33 - 13.50 CC5NC05AA042 35,000 TDR 13.507 - 13.50 CC5AX05AW036 35,000 TOR 13.50 1300 1 �� CE3AA036 35,000 TDR . 13.00 13.50 CE3AA042 35,000 TDR 13.50 - 35,000 TOR 13.50 - 13.50 11.60 CK3BA036 TDR 13.50 13.50 12.60 CK38A042 35,000 13.50 12.01 CK5A/CK5BA042 35,000 TDR 13.50 - 13.50 12.0,- CKSA/CK5BT042 35,000 TDR 13.50 -13.50 11.60 CK5NCK5BW036 35,000' TDR 13.50 - - 12 00 CK5PA042. 35.006- TDR&TXV 13.50 12 UC CK5PT042.. 35,000 TDR&TXV 13.50 - - 11 e:• CK5PW036 35,000 ' TDR&TXV 13.50 - - 18t" ''cjlMzjq?rfx< i:? CCSA/C05AA042 35,000 TDR 13.50 13.50 - CC5A/C05AW036 35,000 TDR 13.50 - 13.50 t CE3AA036 35,000 TDR 13.00 - t 3.00 t ' CE3AA042 35,000 TDR 13.50 - 113.50 ;;.5 CK3BA036 35,000 TDR 13.50 - 13.50 •6: CK38A042 35,000 TDR 13.50 - 13.50 12 OC CK5A/CK5BA042 35,000 TOR 13.50 - 13.50 12.0 CK5A/CK5BT042 35,000 TDR 13.50 - 13.50 2. G,', CK5A/CK56W036 35,000 TOR 13.50 - 13.50 11.6: CK5PA042 35,000 TORBTXV 13.50 - - i2•0'• CK5PT042 35,000 TOR&TXV 13.50 CK5PW036 35,000. TDR&TXV 13.50 7CC5NC05AA036' 35,000 NONE - 13.00 13.0c CC5NCD5AA042 35,000 NONE - 13.00 13.00 1 ?` CC5NC05AW036 35,000 NONE •- 13.00 i�.vJ CC5NCD5AW042 34,600 NONE - 12.50 12.50 CE3AA036 34,600 NONE - 12.50 12.50 CE3AA042 35,000 NONE - 13.00 13.00 1'•3i CF5AA036 35,000 NONE - 12.50 12.50 CK3BA036 35,000 NONE - 13.00 13.00. t 1.3i CK38A042 .35,000 NONE - 13.00 13.00 11.3 CK5NCK5BA036 35.000 NONE - 13.00 13.00 CI<SNCKSBA0:2 35,000 NONE - 13.00 CK5NCK5BE042 35,000 NONE - 13.00 13.0' CK5A/CK58T036 35,000 NONE - 13.00 13.00 t CK5NCK58T042 35,000 NONE ' - 13.00 0.00 036.34 CK5NCK5BW036 35,000 , NONE - 13.00 13. GJ 3•: CK5PA036 35,000 TXV - 13.00 - �= CK5PA042 35,000 TXV - 13.00 CK5PE042 35,000 TXV - 13.00 - 1 CK5PT036 35,000 TXV - 13.00 - CK5PT042 35,000 TXV - 13.00 - CKSPW036 35,000 TXV - 13.00 F(A,B)4BN(F,C)036 34,600 TOR 12.50 - 12.50 FC4CNF036 34.600 TDR&TXV 12.50 - - FG3AAA036 34,006 NONE - 12.50 12.50 F(A.B;46N(F,B,C)042 35,600 TOR 12.50 - :2.50 FC4CN(F.8)042 35,000 TOR&TXV 12.50 - - "' FG3AAA048 35,000 t. ONE - 12.50 12.50 FX48NF036 35.000 x4,1 -:„i -^_•_- 12.50 - - ' 1 FX46NF042 35,600 l L}x :;t 13.00 - - •i. M x A f� A`N Combination ratings continued Standard ti 1 FACTORY - Rating SUPPLIED UNIT INDOOR TOT.'CAP. ENHANCE - SIZE -SERIES UNIT BTUH 1 MENT 13.50 FK4DNF001 34,600 TDR&TXV 13.50 FE4ANF002 35,000 TDR&TXV 13.50 FK4DNF002 35,000 TDR&TXV 14.00 FV4BNF002 35,000 TDR&TXV 14.00 FE4ANF003 35,000 TDR&TXV 14,00 FK4DNF003 35,000 TDR&TXV 14.50 FV4BNF003 35,000 TDR&TXV 14.50 FE4ANF005 36,000 TDR&TXV 14.50 FK4DNF005 36,000 TOR&TXV 14.50 FV4BNF005 36,000 TDR&TXV 14.50 FE4ANB006 36,000 TDR&TXV 14.50 FK4DNB006 36,000 TDR&TXV 13.50 FV4BNB006 36,000 TDR&TXV 13.50 - 13.50 11.70 13.50 CC5A/CD5AA036 34,400 TDR 13.50 CE3AA036 34,000 TDR 13.50 CE3AA042 34,600 I TDR 13.50 CK36AO36 34,600 TDR 14.00 CK5A/CK5BA036 34,600 TDR 13.50 CK5A/CK5BT036 34,600 TDR 13.50 CK5A/CK5BE042 34,600 TDR 13.50 CK5PA036 34,600 TDR&TXV CK5PT036 34,600 TDR&TXV 13.50 CK5PE042 34,600 TDR&TXV 14.00 - 14.00 12.10 14.00 CC5A/CD5AA036 34,400 TDR ' 13.50 CC5A/CD5AA042 34,400 TDR 14.00 CC5A/CD5AW036 34,400 TDR 14.00 CE3AA036 34,000 TDR 14.00 CE3AA042 34,600 TDR 14.00 CK3BA036 34,600 TOR 14.00 CK3BA042 34,600 TDR 14.00 CK5A/CK5BA036 34,600 TDR 14.00 CK5A/CK5BA042 34,600 TDR 14.00 CK5A/CK5BE042 34,600 I TDR 14.00 CK5A/CK5BT036 34,600 TDR 14.00 CK6A/CK5BT042 34,600 TDR 14.00 CK5A/CK5BW036 34,600 TDR 14.00 CK5PA036 34,600 TDR&TXV 14.00 CK5PA042 34,600 TDR&TXV 036-34 CK5PE042 34,600 TDR&TXV 14.00 CK5PT036 34,600 TDR&TXV CK5PT042 34,600 TDR&TXV - CK5PW036 34,600 TDR&TXV 14.00 12.10 14.00 - 14.00 12.10 CCSA/CD5AA036 34,400 TPR 14.00 12.00 13.50 CCSA/CD5AA042 34,400 TOR 14.00 CC5A/CD5AW036 34,400 TDR 14.00 CC5A/CD5AW042 34,200 I TDR 14.00 CE3AA036 34,000 TDR 14.00 CE3AA042 34,600 TDR 14.00 CK3BA036 34,$00 TDR 14.00 CK3BA042 34,600 TDR 14.00 CK5A/CK5BA036 34,600 TDR 14.00 CK5A/CKSBA042 34,600 TDR 14.00 CK5A/CK5BE042 34,600 TDR 14.00 CK5A/CK5BT036 34,600 TDR 14.00 CK5A/CK5BT042 34,600 TDR 14.00 CK5A/CK5BW036 34,600 TDR 14.00 CK5PA036 34,600 TDR&TXV 14.00 . CK5PA042 34,600 TDR&TXV 14.00 CK5PE042 34,600 TDR&TXV 14.00 CK5PT036 34,600 TDR&TXV 14.00 CK5PT042 34,600 TDR&TXV' 14.00 CK5PW036 1 34,600 TDR&TXV 13.50 - -M " 14.00 34,400 TDR CCSA%CD5AA042 14.00 CC5A/CD5AW036 34,400 TOR 14.00 CCSA/C05AW042 34,200 TDR 14.00 CE3AA036 34,000 TDR 14.00 CE3AA042 34,600 TDR 14.00 CK3BA042 34,600 TDR 14.00 CK5A/CK5BA042 34,600 TOR. 14.00 CK5A/CK5BT042 34,600 TDR 4.00 14.00", CK5A/CK5BW036 34,600 TDR 14.00 CK5PA042 34,600 TDR&TXV CK5PT042 34,600 TDR&TXV CKSPW036 34,600 TDR&TXV 2 CC5A/CD5AW036 34,400 "^a CC5A/CD5AA042 34,400 See notes on pg. 22. 14 4i SEER Carrier Standard Gas Furnace or Accessoryy Rating Accessory TDRt Puron TXVt EER 13.00 - - '11.75 13.50 - - 12.00 13.50 - - 12.00 13.50 - - 12.00 14.00 - - 12.40 14.00 - - 12.40 14,00 - - 12.40 14.50 - - 12.85 14.50 - - 12.85 14.50 - - 12.85 14.50 - - -13.05 14.50 - - .13.05 14.50 - - I, 13.05 13.50 - 13.50 11.85 13.50 - 13.50 11.70 13.50 - 13.50 11.95 13.50 - 13.50 11.90 13.50 - 13.50 11.90 13.50 - 13.50 .11.90 14.00 - 14.00 .12.00 13.50 - - 11.90 13.50 - - 11.90 13.50 - - 12.00 13.50 - 13.50 12.05 14.00 - 14.00 12.10 14.00 - 14.00 12.10 13.50 - 13.50 11.90 14.00 - 14.00 12.15 14.00 - 14.00 12.10 14.00 - 14.00 12.15 14.00 - 14.00 12.10 14.00 - 14.00 12.15 14.00 - 14.00 12.20 14.00 - 14.00 .12.10 14.00 - 14.00 12.15 14.00 - 14.00 12.15 14.00 - - 12.05 14.00 - - 12.15 14.00 - - 12.20 14.00 - - 12.05 14.00 - - 12.15 14.00 - - 12.10 13.50 - 13.50 12.05 14.00 - 14.00 12.10 14.00 - 14.00 12.10 14.00 - 14.00 12.00 13.50 - 13.50 11.90 14.00 - 14.00 12.15 14.00 - 14.00 12.10 14.00 - 14.00 12.15 14.00 - 14.00 12.10 14.00 - 14.00 12.15 14.00 - 14.00 12.20 14.00 - 14.00 12.10 14.00 - 14.00 12.15 14.00 - 14.00 12.15 14.00 - - 12.05 14.00 - - 12.15 14.00 - - 12.20 14.00 - - 12.05 14.00 . - - 12.15 14.00 - - 12.10 14.00 - 14.00 12.20 14.00 - 14.00 12.15 14.00 - 14.00 12.10 13.50 - 13.50 11.95 14.00 - 14.00 12.25 14.00 - 14.00 12.20 14.00 - 14.00 12.20 14.00 - 14.00 12.20 14.00 - 14.00 12.20 14.00 - - 12.20 14.00 - - 12.20 14.00 - - 12.20 4.00 14.00", - 14.00 12.25 14.00 - 14.00 12.30 -Combination ratings continued El CC5A/CD5AA036 CC5A/CD5AA042 CC5A/CD5AW036 CC5A/CD5AW042 ,. CE3AA036 .. { CE3AA042 CK3BA036 CK38AD42 CK5A/CK5BA036 CK5A/CK5BA042 CK5A/CK5BE042 CK5A/CK5BT036 CK5A/CK5BT042 CK5A/CK5BW036 036-34 CK5PA036 CK5PA042 CK5PE042 CK5PT036 CCS.AJCDSA4' 2 CC5A/CD5AW Wd CC5A/CD5AW042 CE3AA036 CE3AA042 CK3BA042 CK5A/CK5BA042 CK5A/CK5BT042 CK5A/CK58W036 CK5PA042 CK5PT042 CK5PW036 'CD5AA048 CC5A/CD5AA042 CC5A/CDSAC048 CC5A/CD5AW048 CE3AA042 .CE3AA048 CF5AA048 CK3BA042 CK38AO48 CK5A/CK5BA042 CK5A/CK5BA048 CK5A/CK5BE042 CK5A/CK5BT042 CK5A/CK5BT048 CK5A/CK5BW048 CK5PA042 CK5PA048 CK5PE042 CK5PT042 CK5PT048 CK5PW048 F�A,B;4fA,B;N�F,B,C;048 042-33 FE4AN6006 FE4ANF003 FE4ANF005 FG3AAA048 FK4(CD)NB006 FK4 U NF003 CC5A/C05AA042 CC5A/CD5AC048 COSAA048 CE3AA042 CE3AA048 CK3BA042 CK3BA048 CK5A/CK5BA042 CKSA/CK5BA048 CK5A/CK53E042 See notes on pg. 22. TDR 16 FACTORY- SEER 11.95 34,400 TDR SUPPLIED Carrier UNIT INDOOR TOT. CAP. ENHANCE- Standard Gas Furnace or Accessorryy lAccessoryTDRt SIZE -SERIES. UNIT STUN MENT Rating PuronTXV$ EER 13.50 CK5PT042 34,600 TDR&TXV 13.50 1 - - 12.00 ;ii TDR CK5PW036 34,600 TDR&TXV 13.50 - - 12.00 CC5A/CD5AA036 CC5A/CD5AA042 CC5A/CD5AW036 CC5A/CD5AW042 ,. CE3AA036 .. { CE3AA042 CK3BA036 CK38AD42 CK5A/CK5BA036 CK5A/CK5BA042 CK5A/CK5BE042 CK5A/CK5BT036 CK5A/CK5BT042 CK5A/CK5BW036 036-34 CK5PA036 CK5PA042 CK5PE042 CK5PT036 CCS.AJCDSA4' 2 CC5A/CD5AW Wd CC5A/CD5AW042 CE3AA036 CE3AA042 CK3BA042 CK5A/CK5BA042 CK5A/CK5BT042 CK5A/CK58W036 CK5PA042 CK5PT042 CK5PW036 'CD5AA048 CC5A/CD5AA042 CC5A/CDSAC048 CC5A/CD5AW048 CE3AA042 .CE3AA048 CF5AA048 CK3BA042 CK38AO48 CK5A/CK5BA042 CK5A/CK5BA048 CK5A/CK5BE042 CK5A/CK5BT042 CK5A/CK5BT048 CK5A/CK5BW048 CK5PA042 CK5PA048 CK5PE042 CK5PT042 CK5PT048 CK5PW048 F�A,B;4fA,B;N�F,B,C;048 042-33 FE4AN6006 FE4ANF003 FE4ANF005 FG3AAA048 FK4(CD)NB006 FK4 U NF003 CC5A/C05AA042 CC5A/CD5AC048 COSAA048 CE3AA042 CE3AA048 CK3BA042 CK3BA048 CK5A/CK5BA042 CKSA/CK5BA048 CK5A/CK53E042 See notes on pg. 22. TDR 16 - 13.50 11.95 34,400 TDR 13.50 - 13.50 !T_ 34,400 TDR 13.50 - 13.50 12.00 34,400 TDR 13.50 - 13.50 11.95 34,400 TDR 13.50 - 13.50 12.05 34,400 TDR 13.50 - 13.50 12.00 33,800 TDR 13.50 TDR 13.50 11.90 ,.34,000 ;ii TDR 13.50 - 13.50 11.85' '• 34,600 TDR 13.50 - 13.50 12.10 34,600 TDR 13.50 - 13.50 12.00 34,600 TDR 13.50 - 13.50 12.05 34,600 TDR 13.50 - 13.50 12.00 34,600 TDR 13.50 - 13.50 12.05 34,600 TDR 13.50 - 13.50 12.15 34,600 TDR 13.50 - 13.50 12.00 34,600 TDR 13.50 - 13.50 12.05 34,600 TDR 13.50 - 13.50 12.05 34,600 TDR&TXV 13.50 - - 12.00 34,600 TDR&TXV 13.50 - - 12.05 34,600 TDR&TXV 13.50 - . - 12.10 34,600 TDR&TXV 13.50 - - 12.00 34,600 TDR&TXV 13.50 - - 12.05 34,600 TDR&TXV 13.50 - - 12.05 34,400 TDR 13.50 - 13.5v .2.05 34,400 TDR 13.50 - 13.50 12.05 33,800 TDR 13.50 - 13.50 12.00 34,000 TDR 13.50 - 13.50 11.85 34,600 TDR 13.50 - 13.50 - 12.10 34,600 TDR 13.50 - 13.50 12.10 34,600 TDR 13.50 - 13.50 12.10 34,600 TDR 13.50 - 13.50 12.10 34,600 TDR 13.50 - 13.50 12.10 34,600 TDR&TXV 13.50 - - 12.10 34,600 TDR&TXV 13.50 - - 12.10 34,600 TDR&TXV 13.50 - 12.10 40,500 NONE - 13.00 13.00 11.25 40,500 NONE - 13.00 13.00 11.15 40,000 NONE- 12.50 12.50 11.00 40,500 NONE - 13.00 13.00 1120 41,000 NONE - 13.00 13.00 11.30 41,000 NONE - 13.00 13.00 11.35 40,500 NONE - 12.50 12.50 11.20 40,500 NONE - 13.00 13.00 11.20 40,500 NONE - 13.00 13.00 11.30 40,500 NONE - 13.00 13.00 11.20 40,500 NONE - 13.00 13.00 11.30 39,500 NONE - 12.50 12.50 '11.30 40,500 NONE - 13.00 13.00 11.20 40,500 NONE - 13.00 13.00 11.30 40,500 NONE - 13.00 13.00 11.30 40,500 TXV - 13.00 - 11.20 40,500 TXV - 13,00 - 1130 39,500 TXV - 12.50 - 11,30 40,500 TXV - 13.00 - 11.20 40,500 TXV - 13.00 - 11.30 40,500 TXV 13.00 - . 11.30. 40,500 TDR' 12.50 - 12.50 11.25 41,000 TDR 13.00 - 13.00 11.45 41,500 TDR&TXV 14.00 - - 12.90 39,500 TDR&TXV 13.00 - - 11.95 41,000 TDR&TXV 13.50 - - 12.50 40,000 NONE 12.50 12.50 11.25 41,500 TDR&TXV 14.00 - - 12.90 39,500 TDR&TXV 13.00 - - 12.00 41,000 TDR&TXV 13.50 - - 1255 41,500 TDR&TXV 14.00 - - 12.90 39,500 TDR&TXV 13.00 - - 11.95 41,000 l'DR&TXV 13.50 - - 12.50 40,000 TDR&TXV 12.50 - - 11.10 40,500 1 TDR&TXV 12.50 1- - 1120 40,000 TDR13.50 - 13.50 11.85 40,000 40,500 TDR TDR 13.50 - 13.50 13.50 11.85 40,500 TDR - 13.50 - 13.50 12.00 13.50 11.90 41.000 TDR 13.50 - 13.50 11.95 40,500 TDR 13.50 - 13.50 11.90 40,500 TDR 13.50 - 13.50 12.00 40,000 40,500 TDR TDA 13.50 - 13.50 13.50 11.90 40,5W TDA _- 13.50 1350 1200 40,500 TDR - 13.50 13.50 11.95 - 13.50 11.90 combination ratings continued SEER FACTORY- Carrier Carrier SUPPLIED Gas Furnace or Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard Accessory TDRf or Accessory. TDR+TXV$ Accessory PuronTXV$ EER SIZE-SERIES UNIT BTUH MENT Rating 'CD5PX060 59,000 TXV NONE - - 13.00 - - 12.50 10'65 CC5A/CD5AA060 CCSA/CDSAW )60 56,000 58,000 NONE - - 12.50 13.00 - - 10.90 11 b0 CE3AA060 58,000 NONE NONE - - - - 12.50 - 10.95 CK3BA060 CK5A/CK5BA060 58,000 •58,000 NONE - - 12.50 _ 10.95 10.95 CKSA/CKSBT060 58,000 NONE NONE - - - - 12.50 .13.00 - 11.10 GKSA/CK5BX060 59,000 58,000 TXV - 12.50 - - 10.95 CK5PA060 CK5PT060 58,000 TXV - 12.50 - - - 10.95 11'10 CK5PX060 59,000 TXV TDR - - 13:00 - - - 1250 10.70 F(A,B)4BN(F,B,C)060 58,000 TDR - - - 13.00 11.05 FB4BNB070 FE4ANB006 59,000 59,000 TDR&TXV 13.50 - - - 11'75 10.70 FC4CN(FB)060 58,000 TDR&TXV 12.50 - - 11.05 FC4CNB070 59,000 TD.R&TXV NONE 13.00 - - - - 12.50 - . 10.80 FG3AAA060 FK4DNB006 57,000 59,000 TDR&TXV 13.50 - - - - 11'75 11.75 FV48NB006 59,000 TDR&TXV I 13.50 - - - 11.05 FX4BNB060 . 59,000 TDR&TXV . 13.00 - - 32.50 10.75 11.10 56,000 TDR. CC5A/CD5AA060 CD5PX060 58,000 TDR&TXV 13.00 - - 13.00 11.10 CE3AA060 CK3BA060 58,000 57,500 TDR TOR - - - - - - 13.00 13.00 . 11.10 11.10 ' CK5A/CK5BA060 57,500 57,500 TDR TDR - - - - - - 13.00 11.10 CKSfUCK5BT060 CKSA/CK5BX060 58,500 TDR - - - 13.00 - 11.25 11.10 CK5PA060 57,500 TDR&TXV 13.00 - - - 11.10 CK5PT060 57,500 TDR&TXV 13.00 - - - 11.25 CK5PX060. 58,500 TDR&TXV 13.00 - - CC5A/CD5AA060 56,000 TDR - - - . "1250 - . 10.90 '11.30 C05PX066 58,000 58,000 TDR&TXV TDR 13.00 - - - - - 13.00 11.30 ' _ 1 CE3AA060 CK3BA060 57,500 TDR - - - 13.00 13.00 11.25 11.25 CK5A/CK5BA060 CK5A/CK5BT060 57,500 57,500 TOR TDR - - _. -. _ 13.00 11.25 060-35 CK5A/CK5BX060 58,500 TOR _ 13.00 - 11.40 11.25 CK5PA060 57,500 TDR&TXV 13.00 - - - 11.25 CKSPT060 57,500 TDR&TXV 13.00 - - 11.40 CK5PX060 58,500 TDR&TXV 13:00 - - - CC5A/CD5AA060 56,000 TDR - - - 13.00 11.00 11.40 C05PX060 58,000 TDR&TXV TDR 13.00 - - - - - 13.00 11.40 CE3AA060 CK3BA060 58,000 57,500 TDR - - - - 13.00 11.35 CK5A/CK5BA060 57,500 TDR - - - 13.00 13.00 11.3.5. 11.35 CK5A/CK5BT060 CK5A/CK5BX060 57,500 58,500 TDR TDR - - - - - - 13.00 11.50 CK5PA060 57,500 TDR&TXV 13.00 - - - 11.35` CK5PT060 •57500 TDR&TXV 13.00 - - - 11.35 11.50 CK5PX060 58,500 TDF&TXV 13.00 - - - CK3BA060 57,500 TDR CK5A/CK5BA060 57,500 TDR CK5A/CKSBT060 57,500 TDR CK5PA060 57,500 TDR&TXV 12.50 CK5PT060 57,500 TOR&TXV CK313A060 57,500 TDR - - - 12.50 10.80 CK5A/CK5BA060 57,500 TDR - - - 12.50 10.85 CK5A/CKSBT060 57,500 TDR - - - 12.50 10.85 CK5PA060 57,500 TDR&TXV .. 12.50 - - - 10:85 CKSPT080 57,500 TDA&TXV 12.50 - - - 10.85 UMN ED r-----TDR" l J: CC5A/CD5AA060 56,000 - -• - 12.50 10.55 CK3BA060 61<6A/CK5BA060 57,500 _ 57,500 TDR TDR - - - . - - - 12.50 12.50 10.90 10.95 CK5A/CK5BT060 57,500 TDR - - - 12.50 10.95 CK5A/CK5BX060 .58,00 TOR -. - - 13.00 11.05 CKSPA060 57,500 TDR&TXV 12.50 - - - 10.95 CK5PT060 57;x00 TDR&TXV 12.50 - - - 10.95 _ CK5PX060 58.500 TDR&TXV 13.00 - - 11.05 See notes on pg. 22. 21 Product 58STA/STX Data 4 -Way Muitipoise m6uce-Combustion Gas Fprnace r Input Capacities; 45,000 thru 155,000 Btuh. THE CARRIER 58STA/STX GAS FURNACE The .58STA/STX .4 -way Multipoise Gas Furnaces feature Carrier's QuieTechTM noise reduction system for incredibly gpiet: induced drab •oper-tion. Applications are easy �� ith 4 -way multipoise design, through - the -furnace downflow venting, 13 dif- ferent venting options, and a door designed for easy service access. An inner blower door is provided I'or tighter' sealing in sensitive applica- tions. The 58STA/STX furnaces are approved for use with natural or pro- pane gas. STANDARD FEATURES — QuieTech noise reduction system - :Microprocessor based control center Adjustable heating air temperature rise Adjustable cooling airflow LED • diagnostics and self test feature 4 -way Multipoise furnace, 13 vent applications Only 33.1/3" tall Inner blower door Hot surface Ignition (HSI) Draft safeguard switch to ensure proper furnace venting - Heat pump compatible Residential - inst.ailations .eligible for consumer financing through the Retail Credit Program LIMITED WARRANTY — 20 -year warranty on "Super ST`i" heatexchanger — 1 -year parts «•arrancy on all other components Copyright 2002 Carrier Corporation • i Form SaST- i PQ a . -Physical data :,•a' ' �s • �'r: ril:sJ:, �C .?:� ,ter l UNIT SIZE" . , :!:'u; J `•--�'tb'i ' 4 `;,�' _Si ;r(� 10 ; - 35 �:. ,1�•> :e.. .y?a. � «'i..c.,.: ,31r,:r, '�F:. .y.>..,:_4i'. - l05 08 _ J2'" =:08` '12 .i4?'f ''16'" <'.12:=� ':16"" 22 16 22 20 OUTPUT CAPACITY BTUH' (Nnv.ea:herized ICS) t 58STX Upflow; all 58STA 35,000 36,000 53,000' 54,000 71,000 71,000 89,000 89,000 89,0GO i07,00C• 107,000 125.00: 58STX Downflow/ Horizontal 34,000 31,000 51,000 51,000 E8,000 68,000 85,000 85,000 55,000 102,000 102 t t:: INPUT ETUH' 58STX Upflow; all 58STA 44,000 4,,000 66,000 66,000 88,000 83.000 110,0CC 110.000 110,00CI132.GCC 132.000. 58ST zontal flow/ Horizontal 4P000 42,000 63.000 63.0CC 84,CCC• 84,CCC 105,0CC 105.GCC i05,000 :28,000 SHIPPING V/EIGHT (Lb) 104 107 111 115 127 140 135 148 152 149 163 17: CERTIFIED TEMP RISE RANGE (°F) 30-60 20-53 4 70 33-60 40-70 30-60. 5C-80 40-70 30-60 SO-SO 4x70 45-7: CERTIFIED EXT STATIC Heating PRESSURE Cooling 0.10 0.10 0.12 0.12 0.15 0.15 0.20 0.20 0.20 0.20 0.20 0.2_ 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8 0.5 0.5 0; AIRFLOW/ CFM; Heating Cooling 920 1250 830 1195 1375 1505 1335 1515 1900 1525 1653 17;• 845 1160 900 1200 1385 1720 1355 1680 2220 1710 2110 2_3,: A'UE;a' Nonweatherized ICS 80.0 80.0 80.0 80.0 60.0 80.0 80.0 80.0 80.0 80.0 83.0 .c -1 i` LIMIT CONTROL SPST Solid -State Time Operation HEATING 61-OV/F.R CONTROL BURNERS (Monoport) 2 2 3 1 3 3 1 4 1 4 1 5 1 5 5 6 7 GAS CONNECTION SIZE 1/2 -in. NPT White -Rodgers 4.5 (Natural Gas) 13.6 (Natural Gas) Hot Surface GAS VALVE (Redundant) Manufacturer Minimum Inlet Pressure (In. wc) .Maximum Inlet Pressure (In. wc) IGNITION DEVICE Gas inp .r: ratings are certified for elev_ticns to 2000 It. For eieva:ions above 2000 It, reduce ratings 4% for each LOCO h above sea level. Rafe: tc Na:!or.a Fac: Gas code Table F4 or furnace Installation Instructions. In Canada, darala the unit 101. for elevations 2000 to 4500 h above sea lave: 1 Ca-lacity in accordance with U.S. Government DOE test procedures. snov:n is for bottom only return -air supply. For air delivery above 1800 CF.Mr see Air Delivery Table Icr other options.A fine., is required to. eacr return -air supply. _ ICS - Is lased Combustion System Blower performance -data - -,1 ,.,,35 .��_-<,n��.,,, 55 UNIT SIZE `r - • QB12. -08 2.% J4:;Y. r16: :12, '.:J6' 22•- ;16: 20 20 DIRECT -DRIVE MOTOR Hp (PSC) 1/5 1/3 -1/5 1/3 1/3 1/2 1/3 1/2 3'4 1;2 3'4 a. MOTOR FULL LOAD AMPS 2.9 5.2 2.9 5.2 5.2 .7.9 5.2 7.9 1 11.1 1 7.9 11.1 11 1 RPM (Nomina!) - Speeds 1073.3 1075-3 1075.3 1075.3 1075.3 1075.3 1075.3 1075.31075.3 1.075-3 10%5.3 1=7=•_ E_OWERWHEEL DIAMETER X WIDTHS(in.) 10x6 10x6 10x6 10x6 }0x6 1 lox 101 10x8 110x1011x11 1 10x10 11x11 I 11x1: PSC•Pe:n:ar.en; Split Capacitor