06-0671 (BLCK) Title 24TITLE 24 REPORT
Title 24 Report for:
S-obnstr .ct. o .
78-233 B.i.r-kda1.e Court
La Quinta, CA
Project Designer:
Report Prepared By:
Joan D. Hacker
Insu-Form Inc.
68255 Corta Road
Cathedral City, CA 92234
(760) 324-0216
Job Number:
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
i eop6-ls
OA /VL3 0-By5 E •
Date:
9/8/2005
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400.
EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655
(11
I - TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Checklist 7
Form C -2R Computer Method Summary 9
HVAC System Heating and Cooling Loads Summary 14
Room Load Summary 18
EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Soba Construction
Const.
Assembly
U -Value
9/8/2005
Project Title
X❑ Single Family Detached
Date
78-233 Birkdale Court La Quinta
❑ Existing Building
❑ Multi -Family
❑ Existing Plus Addition
Project Address
90 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units:
Building Permit #
Insu-Form Inc.
(760) 324-0216
(East)
88.3
-0Fx
0.35
Plan Check / Date
Documentation Author
Telephone
Computer Performance
15
(South)
Field Check / Date
Compliance Method (Package or Computer)
Climate Zone
Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 5,358 ft' Average Ceiling Height: 10.2 ft
Total Conditioned Slab Area: 5,358 ft2
Building Type:
Const.
Assembly
U -Value
(check one or more)
n/a
X❑ Single Family Detached
❑ Addition
❑ Single Family Attached
❑ Existing Building
❑ Multi -Family
❑ Existing Plus Addition
Front Orientation: (East)
90 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units:
1.00
Number of Stories:
1 ❑ Raised Floor
Component
Slab On Grade
R-19 Wall (W.19.2x6.16)
R-38 Roof (R.38.2x14.16)
Slab On Grade
FENESTRATION
Frame
Type
Const.
Assembly
U -Value
Location/Comments
(attic, garage, typical, etc.)
n/a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Wood
0.065
Exterior Wall
Wood
0.028
Exterior Roof
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes / No
Front
(East)
88.3
-0Fx
0.35
0.29
Bug
Screen
Left
(South)
132.0
0.35
0.29
Bug
Screen
X❑
❑
❑ x❑
Rear
(West)
154.5
0.35
0.29
Bug
Screen
X❑
❑
❑ X❑
Right
(North)
45.4
0.34
0.26
Bug
Screen
X❑
❑
❑ X❑
Front
(East)
168.0
0.34
0.26
Bug
Screen
X❑
❑
❑ X❑
Front
(East)
70.5
0.29
0.36
Bug
Screen[g]
❑
❑ X❑
Rear
(West)
184.0
0.33
0.33
Bug
Screen
X❑
❑
❑ a
Rear
(West)
40.0
0.29
0.36
Bug
Screen
X❑
❑
❑ a
Left
(South)
96.0
0.34
0.26
Bug
Screen
X❑
❑
❑ x❑
Left
(South)
24.0
0.29
0.36
Bug
Screen
X❑
❑
❑ x❑
Rear
(West)
68.0
0.34
0.26
Bug
Screen
X❑
❑
❑ X❑
Right
(North)
111.5
0.35
0.29
Bug
Screen
X❑
❑
❑ x❑
Run Initiation Time: 09/08/05 10:43:00 Run Code: 1126201380
Ener
Pro 3.1 By Ener Soft
User Number: 2655
Job Number:
Pa e:3 of 21
'Certificate of Comaliance: Residential . (Part 1 of 2) CF -1 R
Soba Construction
Overhang Side Fins
9/8/2005
Project Title
Yes / No
Date
78-233 Birkdale Court La Quinta
❑ a
❑ ❑
Project Address
1:1 1:1
Building Permit #
Insu-Form Inc.
(760) 324-0216
El F1
-
El El
Plan Check / Date
Documentation Author
Telephone
El
Computer Performance
15
Field Check / Date
Compliance Method (Package or Computer)
Climate Zone
Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 5,358 ft2 Average Ceiling Height: 10.2 ft
Total Conditioned Slab Area: 5,358 ft2
Building Type:
(check one or more)
K Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (East) 90 deq Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
BUILDING SHELL INSULATION
Const.
Component Frame Assembly Location/Comments
Type Type U -Value (attic, garage, typical, etc.)
FENESTRATION Shadinq Devices
Type Orientation Area Fenestration Exterior
Overhang Side Fins
SF U -Factor SHGC Shading
Yes / No
Yes / No
Skylight 34.6 0.40 0.29 None
❑ Q
❑ a
❑ ❑
❑ ❑
1:1 1:1
El
El El
El F1
-
El El
❑❑
1:1 1:1
El
1:1 El
❑❑
1:1 El
❑❑
El FJ
El El
Run Initiation Time: 09/08/05 10:43:00 Run Code: 1126201380
Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number.
Pa e:4 of 21
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Soba Construction 9/8/2005
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments
Cantral Furnarp 80% AFUE Ducts in Attic 42 Setback Zone 1
Centml Eurnnre _80% AFUE Ducts in Attic 42 Setback Znne 2
Central F irnara 80% AFUE Ducts in Attic 4.2 Setback Zone 3
('antral Fiirnaca 80% AFUE Ducts in Attic 4.2 Setback Casita
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 49 Sathark 7nne 1
Split Air Conditioner 12 0 SEER Ducts in Attic 42 Sethack 7onp 2
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 3
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Casita
WATER HEATING SYSTEMS
Rated 1 Tank Energy Facts 1 External
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul.
System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value
American G82-5OT38-3 Small Gas Pine Insulation 2- 46000 50 0.65 n/a n/a
For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm:
Addr
T epho e:
Lic. #:
grraRr re) (date)
nforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Documentation Author
Name: Joan D. Hacker
Title/Firm: Insu-Form Inc.
Address: 68255 Corta Road
Cathedral City, CA 92234
Telephone: (760) 324-0216
0
(si tj
) (date)
(signature/stamp) (date)
Run Initiation Time: 09/08/05 10:43:00 Run Code: 1126201380
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 21
Certificate of Compliance: Residential (Addendum) CFA R
Soba Construction 9/8/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adeouacv of the justification, and may refect a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. PlanT Field
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
1364 sqft Exposed Slab Floor, 3.50" thick at Zone 1
HIGH MASS Design(see C -2R) -Verify Thermal Mass:
1156 sqft Exposed Slab Floor, 3.50" thick at Zone 2
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
1006 sqft Exposed Slab Floor, 3.50" thick at Zone 3
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
1200 sqft Exposed Slab Floor, 3.50" thick at Zone 4
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
632 sqft Covered Slab Floor, 3.50" thick at Casita
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. --FWn7 Field
Run Initiation Time: 09/08/05 10:43:00 Run Code: 1126201380
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 21
.Mandatory Measures Checklist: Residential (Page 1 of 2) MF71 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
❑X 1150(,): Minimum R-19 ceiling insulation.
§150(b): Loose fill insulation manufacturer's labeled R -Value.
150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
❑§
i( not apply to exterior mass walls).
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
E] §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
El§150(e):
Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
❑X §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA orACCA.
§150(i): Setback thermostat on all applicable heating and/or cooling systems.
F] §1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined intemal/extemal insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 2655 'Job Number. Page:7 of 21
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER JENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
I
X § 150(m): Ducts and Fans
❑ .
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
I duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
I
{ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
I from solar radiation that can cause degradation of the material.
I
§ 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
i
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
LXJ §115: Gas fired central fumaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§118 (f): Cool Roof material meet specified criteria
Lighting Measures
F§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
FX_1 §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 21
Computer Method Summary (Part 1 of 3) C -2R
Sofia Cnnstructton 9/8/2005
Project Title Date
78-233 RirkdalP-,purt I q_Qijinta
Project Address Building Permit #
lnsu-Form Inc_ (760) 324-0216
Documentation Author Telephone Plan Check/Date
Com utlreerformancQ 15 Field Check/Date
Compliance Method (Package or Computer) Climate Zone
Source Energy Use Standard Proposed Compliance
(kBtu/sf-yr) Design Design Margin
Space Heating
2.82
3.23
-0.42
Space Cooling
38.15
38.03
0.12
Domestic Hot Water
5.32
5.01
0.30
Totals
46.29
46.28
0.01
Percent better than Standard:
0.0%
Total Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
BUILDING ZONE INFORMATION
Zone Name
5,358 ft
Single Fam Detached
(East) 90 deg
1.00
1
Floor Area Volume
1 364
1 156
2„206
6.32
OPAQUE SURFACES Solar
Act. Gains
Type Area U -Fac. Azm. Tilt Y / N
Wall 190 ---0-00- '90 9Q
Wall 264 006.5 180 90
Wall 352 0 065 270 g0
Wall 839 0.065 0 90
Rnnf 1.364 0.028 270 _Q
Wall ---330 OA65 180 90
Wall 30A x.065 270 2Q
Wall 700 0 oss a gp
W:;Il— 374 0.065 _---90_ ----a0_
Wall 278 0.06 180 90
Wall X28_ 0.065 270 90
Wall -999 0.065 o 9_Q
Boot— --J-QM —0-02B_ 225 _ 0
Wall 254 0_0.6`..2 180 9.Q
Wau X67 o.oss 9-0 ---aQ
Wall —2.82 0.065 180 90
Wall _9.54 0 065 -0 90
/all— 26 ---Q- 06.5 _270_ 9D
Rnnf 6.32 0.028 925_ 0
Floor Construction Type: ❑ Raised Floor ❑X Slab Floor
Total Fenestration Area: 22.7%
Total Conditioned Volume: 54,736 ft 3
Total Conditioned Slab Area: 5,358 ft 2
# of Thermostat Vent
Units Zone Type Type Hgt. Area
n �. f nnditinnPd SPthack 2 n/a
0 22 Conditioned SPthack 2 n/a
041 Cnnditioned _Sethack 2 n/a
0"12 Conditioned Setback n/a
Form 3 Reference
lone 2
Zone 2
Zone 3
7nne 3
7nne 3
Location / Comments
Run Initiation Time: 09/08/05 10:43:00 Run Code: 1126201380
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:9 of 21
Co'mDuter Method Summary (Part 2 of 3) C -2R
Soba Construction 9/8/2005
Project Title Date
FENESTRATION SURFACES
U- Act. Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
-I-
Windnw
Front
(Fast
inn
-0-350-
0.29
90
2
Window
Left
(South)
20.0
0.350
0.29
180
3
WindowLeft
Wd.
South
21.0
0.350
0.29
180
4
Window
Left
South
25.0
0.350
0.29
180
5
Window
Rear
West
12.5
0.350
0.29
270
6
Window
Rear
(West)
36.0
0.350
0.29
270
7
Window
Right
North)
21.4
0.340
0.26
0
8
Window
Front
(East)
56.0
0.340
0.26
90
9
Window
Front
(East)
56.0
0.340
0.26
90
]R
Window
Front
(East)
56.0
0.340
0.26
90
11
Window
Front
(East)
52.5
0.290
0.36
90
12
Window
Front
(East)
8.0
0.350
0.29
90
13
Window
Bear
(Nas1).
184.0
0.330
033
270
14
Window
Rear
West
12.0
0.290
0.36
270
15
Window
Front
(East)
13.5
0.350
0.29
90
16
Window
Front
East
12.0
0.350
0.29
90
17
Window
Left
(South)
48.0
0.340
0.26
180
18
Window
Left
(South)
24.0
0.290
0.36
180
19
Window
Rear
(West)
36.0
0.350
0.29
270
20
Window
Rear
(West)
8.0
0.350
0.29
270
21
Window
Rear
(West)
8.0
0.350
0.29
270
2Z
Window
Rear
(West)
20.0
0.340
0.26
270
23
Window Right
(North)
10.0
0.350
0.29
0
24
Window
Right
(North)
27.5
0.350
0.29
0
25
Window
Right
(North)
20.0
0.350
0.29
0
26
Window
Left
(South)
24.0
0.350
0.29
180
27
Window
Left
(South)
24.0
0.350
0.29
180
28
Window
Left
(South)
48.0
0.340
0.26
180
29
Window
Rear
(West)
54.0
0.350
0.29
270
.qQ Fagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
_900 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle �s
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eagle Windows
90 Eaqle Windows
90 Eaale Windows
90 Eaale Windows
90 Eaqle Windows
Zone 1
Zone 1
Zone 1
Zone 1
Zone 1
Zone 1
Zone 2
Zone 2
Zone 2
Zone 2
Zone 2
Zone 2
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
Zone 3
90 Eagle Windows Zone 3
90 Eagle Windows Zone 3
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt.
LEA
REA Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
4.0
2.5
2.0
0.1
2.0
2.0
2
Bug Screen
0.76
4.0
2.5
2.0
0.1
2.0
2.0
3
Bug Screen
0.76
3.0
2.4
2.0
0.1
2.0
2.0 _
4
Bug Screen
0.76
5.0
2.5
2.0
0.1
2.0
2.0
5
Bug Screen
0.76
5.0
2.5
2.0
0.1
2.0
2.0
6
Buq Screen
0.76
6.0
3-0
2.0
0.1
2.0
2.0
7
Bug Screen
0.76
8.0
2.8
2.0
0.1
2.0
2.0
8
Bug Screen
0.76
8.0
3.5
8.0
0.1
8.0
8.0
9
Buq Screen
0.76
8.0
3.5
8.0
0.1
8.0
8.0 _
10
Bug Screen
0.76
8.0
3.5
8.0
0.1
8.0
8.0
11B
cu Screen
0.76
2.5
7.0
8.0
0.1
8.0
8.0
12
Bug Screen
0.76
4.0
2.0
2.0
0.1
2.0
2.0
13
Bug Screen _ _
0.76
8.0
23.0
17.0
0.1
17.0
17.0
14
Bug Screen
0.76
2.0
2.0
17.0
0.1
17.0
17.0
15
Bug Screen
0.76
4.5
3.0
2.0
0.1
2.0
2.0
T6 6
Bug Screen
0.76
3.0
2.0
2.0
0.1
2.0
2.0
17
Bug Screen
0.76
8.0
3.0
2.0
0.1
2.0
2.0
18
Bug Screen
0.76
8.0
3.0
2.0
0.1
2.0
_
2.0
19
� Screen
0.76
6.0
3.0
2.0
0.1
2.0
_
2.0
20B�cu
Screen
0.76
4.0
2.0
2.0
0.1
2.0
2.0
21
Bug Screen
0.76
4.0
2.0
2.0
0.1
2.0
2.0
22
Bug Screen
0.76
8.0
2.5
2.0
0.1
2.0
2.0 _
23
Bu S� creen
0.76
5.0
2.0
2.0
0.1
2.0
2.0
24
Buo Screen _
0.76
5.5
2.5
2.0
0.1
2.0
2.0
25
Buq Screen
0.76
4.0
2.5
2.0
0.1
2.0
2.0 _
26
Bug Screen
0.76
6.0
2.0
2.0
0.1
2.0
2.0
27
Bug Screen
0.76
6.0
3.0
40.0
0.1
40.0
40.0
28
Bug Screen
0.76
8.0
3.0
35.0
0.1
35.0
_
35.0
29
Bug Screen
0.76
6.0
3.0
2.0
0.1
2.0
2.0
Run Initiation Time 09/08/05 10.43.00 Run Code: 1126201380
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 10 of 21
Comauter Method Summary (Part 2 of 3) C -2R
Soba Construction 9/8/2005
Project Title Date
FENESTRATION SURFACES
U- Act. Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
240
18.0
Window
Right
(North)
_3D
31
Window
Right
(North)
32
Skylight
Left
(Southwest)
33
Window
Front
(East)
34
Window
Front
(East)
35
Window
Front
(East)_
36
Window
Left
(South)
37
38
Window
Window
Rear
Rear
(West)
(West)
3,q
Window
Right
(North)
40
Window
Rear
(West)
240
18.0
0^340
0.350
0.26
0.29
34.6
0.400
0.29
36.0
0.350
0.29
18.0
0.290
0.36
8.8
0.350
0.29
18.0
-0 350
0.29
48.0
0.340
0.26
24.0
0.290
0.36
36.0
0.350
0.29
4.0
0.290
0.36
INTERIOR AND EXTERIOR SHADING
#
Exterior Shade Type
SHGC
30
Bug Screen
0.76
31
Bug Screen
0.76
32
None
1.00
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
0.76
36
Bug Screen
0.76
37
Bug Screen
0.76
38
Bug Screen
0.76
39
Bug Screen
0.76
40
Buq Screen
0.76
8.0 3.0
6.0 3.0
6.0 3.0
3.0 3.0
3.5 2.5
3.0 2.0
8.0 3.0
8.0 3.0
6.0 3.0
2.0 2.0
0_ _9.0. Eagle Windows
7one 3
0 90 Eagle Windows
Zone 3
225 0 Eagle Windows
Zone 3
90 90 Eagle Windows
Casita
90 90 Eagle Windows
Casita
90 90 Eagle Windows
Casita
180 90 Eagle Windows
Casita
270 90 Eagle Windows
Casita
270 90 Eagle Windows
Casita
0 90 Eagle Windows
Casita
270 90 Eagle Windows
Casita
Overhang Left Fin
Right Fin
Len. Hgt. LExt. RExt. Dist. Len.
Hgt. Dist. Len. Hgt.
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
3.0
0.1
3.0
3.0
3.0
0.1
3.0
3.0
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page: 11 of 21 1
Computer Method Summary (Part 3 of 3) C -2R
Soba Construction 9/8/2005
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
F2
Length Factor
Insulation
R -Val. Depth
Location / Comments
Slab Perimeter
Area
Thick.
Heat
Slab Perimeter
Inside
Location
Type
(sf)
(in.)
Cap.
Cond. Form 3 Reference
R -Val.
Comments
Concrete, Heavyweight
1364
—3M
9$_
-OM n/a
0
Zone 1 / Slab on Grade
Concrete, Heavyweight
1.156
3_50
28
0_98 n/a
0
Zone 2 / Slab on Grade
Concrete. Heavyweight
1.006
3.50
28
0.98 n/a
0
Zone 3 / Slab on Grade
Concrete, Heavyweight
1.200
3_50
28
0_98 n/a
0
Zone 3 / Slab on Grade
Concrete Heavyweight
632
3.50
28
0.98 n/a
2
Casita / Slab on Grade
PERIMETER LOSSES
Type
F2
Length Factor
Insulation
R -Val. Depth
Location / Comments
Slab Perimeter
22 0.76
0 0 0
Zone 1
Slab Perimeter
i$ —0-7-6.
—�U 0
Slab Perimeter
18 0.76
0 0 0
Zone 3
Slab Per=1e
_38 -0-Z6
0.0 0
Zone 3
Slab Perimeter
18 0.76
0.0 0
Casita
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic,
etc.)
R -Value Type
Comments
Central Furnace
80%AFUE
Ducts in Attic
4.2 Setback
Zone 1
Central Furnace
80%AFUE
Ducts in Attic
4.2 Setback
Zone 2
_
Central Furnace
80%AFUE
Ducts in Attic
4.2 Setback
Zone 3
Central Furnace
80%AFUE
Ducts in Attic
4.2 Setback
Casita
Hydronic Piping
Pipe Pipe
Insul.
System Name
Length Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc)
R -Value Type
Comments
Split Air Conditioner
12.0 SEE
Ducts in Attic
4.2 Setback
Zone 1
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2 Setback
Zone 2
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2 Setback
Zone 3
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2 Setback
Casita
WATER HEATING SYSTEMS
Ratedl Tank
Energy Fact!
1 Tank Insul.
Water Heater
Water Heater Distribution
# in Input Cap.
or Recovery
Standby R -Value
System Name
Type
Type
Syst. (Btu/hr) (gal)
Efficiency
Loss (%) Ext.
American G82 -50T38-3
Small Gas
Pipe Insulation
2 46.000 50
0.65
n/a n/a
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy
factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated
Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Run Initiation Time: 09/08/05 10:43:00 , Run Code: 1126201380
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 12 of 21
Computer Method Summary (Addendum) C -2R
Soba Construction 9/8/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified, in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted.I Plan Field
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
1364 sgft Exposed Slab Floor, 3.50" thick at Zone 1
HIGH MASS Design(see C -2R) -Verify Thermal Mass:
1156 sgft Exposed Slab Floor, 3.50" thick at Zone 2
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
1006 sgft Exposed Slab Floor, 3.50" thick at Zone 3
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
1200 sgft Exposed Slab Floor, 3.50" thick at Zone 4
HIGH MASS Design(see C -2R) - Verify Thermal Mass:
632 sqft Covered Slab Floor, 3.50" thick at Casita
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a,CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Paoe:13 of 21 1
IHV -AC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Soba Construction 9/8/2005
SYSTEM NAME FLOOR AREA
Zone 1 1,364
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
74,000
Total Output (Btuh)
74,000
Output (Btuhlsgft)
54.3
Cooling System
Output per System
40,000
Total Output (Btuh)
40,000
Total Output (Tons)
3.3
Total Output (Btuh/sgft)
29.3
Total Output (sgft/Ton)
409.2
Air System
CFM per System
1,395
Airflow (cfm)
1,395
Airflow (cfm/sgft)
1.02
Airflow (cfm/Ton)
418.5
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions -
26.0 of 69.3 of
Outside Air
0 cfm
Supply Fan
1395 cfm
69.3 of
69.3 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensiblel
Latent
CFM
I Sensible
1,263
21,025
3,252
395
20,377
0
1,051
1,019
0
0
0
01
0
0
0
0
0
1,051
1,019
23,1287[777732521 22 414
BDP CO. 563AN042-A 25,323 11,533 74,000
Total Adjusted System Output 25,323 11,5331 74,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
earn Temperatures at Time of Heating Peak)
118.8 of
Heating Coil
K Return Air Ducts '4
upp y lr ucts
118.10F
ROOMS
70.0 of
1000LING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
111.0 / 77.4 of 78.7 / 67.0 of - 78.7 66.9 of 61.8 / 60.7 of
Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 62.5 / 61.0 of
1395 cfm 56.1% R.H. ROOMS
78.7/67.0 of 78.0166.8 of
Return Air Ducts '
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 14 of 21
IHV -AC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Soba Construction 9/8/2005
SYSTEM NAME FLOOR AREA
Zone 2 1,156
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
70,000
Total Output (Btuh)
70,000
Output (Btuh/sgft)
60.6
Cooling System
Output per System
47,000
Total Output (Btuh)
47,000
Total Output (Tons)
3.91
Total Output (Btuh/sqft)
40.7
Total Output (sgft/Ton)
295.1
I
Air System
CFM per System
1,595
Airflow (cfm)
1,595
Airflow (cfm/sgft)
1.38
Airflow (cfm/Ton)
407.2
Outside Air (%)
0.0
Outside Air (cfm/sqft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
ICOILHTG.PEAK
CFM
I Sensible
Latent
I CFM 1 Sensible
1,316
23,825
2,9781 542' 22,995
0
'
1,150
0
1,191
0
0
0
0 of 0
0
I 0
1,150
1,191
26 207 2,9781 1 25,295
BDP CO. 563AN048-A 31,268 11,347 70,000
I �
I
I
Total Adjusted System Output 31,268 11,347 ? 70,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm j r Jan 12 arr
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 OF 69.3 OF 69.3 OF 110.30F
�* Supply Air Ducts
Outside Air �
0 cfm Supply Fan Heating Coil 109.6 °F
1595 cfm ' ROOMS
69.3 of 70.0 of
04 Return Air Ducts
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I
111.0 / 77.4 of 78.7 / 66.0 of 78.7 / 65.9 of . 60.4 / 59.3 of
Outside Air
0 cfm
78.7 / 66.0 of
Supply Fan Cooling Coil
1595 cfm
Return Air Ducts
Supply Alr Ducts
61.1 / 59.5 of
52.7% R.H. i ROOMS
78.0 / 65.8 of
EnergvPro 3.1 By EnergySoft User Number. 2655 Job Number: Paae:15 of 21
IHV -AC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Soba Construction 9/8/2005
SYSTEM NAME FLOOR AREA
Zone 3 2,206
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems 1
Heating System
Output per System
70,000
Total Output (Btuh)
70,000
Output (Btuh/sqft)
31.7
Cooling System
Output per System
47,000
Total Output (Btuh)
47,000
Total Output (Tons)
3.9
Total Output (Btuh/sqft)
21.3
Total Output (sgft/Ton)
563.2
Air System
CFM per System
1,595
Airflow (cfm)
1,595
Airflow (cfm/sgft)
0.72
Airflow (cfm/Ton)
I 407.2
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
JEATING SYSTEM PSYCHROMETRICS
26.0 of 69.4 of 69.4 of
Outside Air
0 cfm
69.4 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK 11COILHTG.PEAK
CFMISensiblel Latent 11CFM1 Sensible
1,387
26,062
1,026
503
21,385
0
1,303
1,069
0
0
0
0
01
0
0
0
0
1,303
1,069
i 28,668 1,026 23 523
BDP CO. 563AN048-A 32,580 9,478 70,000
I
Total Adjusted System Output 32,580 9,478 70,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
-earn Temperatures at Time of Heatina Peak)
110.30F
Supply Fan Heating Coil
1595 cfm
�% Return Air Ducts 14
Supply Air Ducts
109.7 of
ROOMS
70.0 of
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 77.4 of 78.8 65.2 of 78.8 / 65.1 of 59.7 ! 58.5 of
Supply Air Ducts
Outside AirO.
0 cfm Supply Fan Cooling Coil 60.5 / 58.8 of
1595 cfm 49.9% R.H. ROOMS
78.8/65.2 of 78.0 / 65.0 of
h Return Air Ducts 4
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 16 of 2�
WAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Soba Construction 9/8/2005
SYSTEM NAME FLOOR AREA
Casita 632
Total Room Loads
I
I Return Vented Lighting
Return Air Ducts
I
Return Fan
I
Ventilation
Supply Fan
i
Supply Air Ducts
TOTAL SYSTEM LOAD
i
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
ICFM
Sensible
739
10,547
294 221
8,929
0
527
446
0
0
0
0
0 0
0
0
0
527
II
I 446
11,602 2941 9 822
BDP CO. 563AN024-A 13,823 7,854 37,000
I
it
Total Adjusted System Output 13,823 7,854 37,000
(Adjusted for Peak Design Conditions)
I TIME OF SYSTEM PEAK Aug 2 pm ! Jan 12 ami
P-IEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I
26.0 OF 69.5 OF 69.5 OF 108.10F
0 :; Supply Air Ducts
--(
Outside Air
0 cfm 107.6 of
Supply Fan Heating Coil
895 cfm ROOMS
69.5 of 70.0 of
Return Air Ducts
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 77.4 of 78.5 / 67.8 OF 78.5 / 67.7 of 64.1 / 63.1 of
311 0 Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 64.7 / 63.3 of
895 cfm 59.2% R.H. ROOMS
78.5/67.8 of 78.0 / 67.7 of
Return Air Ducts I
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:17 of 21
ROOM LOAD SUMMARY
PROJECT NAME
Soba Construction
DATE
9/8/2005
SYSTEM NAME
Zone 1
FLOOR AREA
1,364
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 1
Zone 1
1
1,263
21,025
3,252
1,263
21,025
3,252
395
20,377
PAGE TOTAL 1 11263 21,025 3,252 395 20,377
TOTAL 1 1,263 21,025 3,252 395 20,377
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 18 of 21
ROOM LOAD SUMMARY
PROJECT NAME
DATE
Soba Construction
9/8/2005
SYSTEM NAME
FLOOR AREA
Zone 2
1,156
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 2
Zone 2
1
1,316
23,825
2,978
1,316
23,825
2,978
542
22,995
PAGE TOTAL 1 1,316 23,825F 2,978 1 542 22,995
TOTAL 1 1,316 23,825 2,978 542 22,995
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:19 of 21
ROOM LOAD SUMMARY
PROJECT NAME
DATE
Soba Construction
9/8/2005
SYSTEM NAME
FLOOR AREA
Zone 3
2,206
ROOM LOAD SUMMARY
PAGE TOTAL
TOTAL
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 3
Zone 3
1
675
12,691
468
675
12,691
468
257
10,939
Zone 3
Zone 4
1
711
13,371
558
711
13,371
558
246
10,446
PAGE TOTAL
TOTAL
1 11387
26,062
1,026
503
21,385
1 11387
26,062
F 1,026
503
21,385
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:20 of 21
IRGOM LOAD SUMMARY
PROJECT NAME
DATE
Soba Construction
9/8/2005
SYSTEM NAME
FLOOR AREA
Casita
632
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Casita
Casita
1
739
10,547
294
739
10,547
294
221
8,929
PAGE TOTAL 1 739 10,547 294 221 8,929
TOTAL 1 739 10,547 294 221 8,929
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:21 of 21