13-0754 (SFD) Revision 1 Title 24PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Hopwood US Investment LP
Building Type 5 single Family 0 Addition Alone
1 0 Multi Family 0 Existing+ Addition/Alteration
Date
811212013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Lennox SLP80UH09OV60C-* includes credit for a 11.4 EER Condenser. A certified HERS rater must field verify the installation of
the conrect Condenser.
The HVAC System Hvac #3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Hvac #3 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums.
The Cooling System Lennox SLP80UH090V60C-* includes credit for a 11.4 EER Condenser A certified HERS rater must field verify the installation of
the correct Condenser.
The HVAC System Hvac #4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
Compliance credit for quality installation of insulation has been used. HERS field verification is required.
The HVAC System Hvac #4 has Ducts, Plenums and the HVAC unit locatedtotall thi?Condition-,WMspD—ac(�,7—A-ceitifiedJJ—ERS rater must visually
verify the installation of the HVAC unit and all Ducts and Plenums. Met Pei OWNITA
SAFETY DEPT.
r-1 r, r-.) 'e—, " 9 —
FO� 60 iki I 6'J V ffL)---
STRUCTIOru
DATE
By
EnergyPro 5. 1 by EnergySoft User Number: 3665 RunCode: 2013-08-12TI5:21:07 ID: Page 9 of 38