Loading...
13-1363 (SFD) Title 24PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name 29th Street Citrus Project LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11/27/2013 Project Address 50625 Breva La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,675 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 3,567 New Roof Wood Framed Attic R-38 3,675 Radiant Barrier New Slab Unheated Slab -on -Grade None 3,675 Perim = 248' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (E) 74.0 0.480 0.25 2.0 none Bug Screen New Front (E) 64.0 0.610 0.21 2.0 none Bug Screen New Left (S) 64.0 0.610 0.21 2.0 none Bug Screen New Left (S) 90.0 0.480 0.25 2.0 none Bug Screen New Rear (tM 93.9 0.480 0.25 2.0 none Bug Screen New Rear (VO 192.0 0.610 0.21 16.0 none Bug Screen New Right (N) 85.7 0.480 0.25 2.0 none Bug Screen New Right (N) 15.4 0.480 0.25 3.0 none Bug Screen New Rear (W) 64.0 0.610 0.21 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 New Casita Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING 1 C17 Y ®F Qty. Type Gallons Min. Eff Distribution,, , h,I ,n,IS003-s 1i 1 Instant Gas 0 0.81 No Pipe Insulation-'-" �ty"i'G & S,[�Ff=�-eiVp'' � 1 Instant Gas 0 0.81 No Pipe Insulation )�� eta ►`UR CON4ira J� A v� I JV Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-11-27711:47:21 `' 10: _ Page 3 of 3 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name 29th Street Citrus Project LLC Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11112712013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 2,335.0 ft' Exposed Slab Floor, 3.500" thick at Whole House HIGH MASS Design - Verify Thermal Mass: 1,000.0 ftz Covered Slab Floor, 3.500" thick at Whole House HIGH MASS Design - Verify Thermal Mass: 100.0 ft' Exposed Slab Floor, 3.500" thick at Casita HIGH MASS Design - Verify Thermal Mass: 240.0 ftz Covered Slab Floor, 3.500" thick at Casita The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System BDP CO. 561AJ042-' includes credit fora 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Whole House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System Whole House incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System BDP CO. 561 AJ030-' includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Casita incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System Casita incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Of / � Al Ire OF LA `; i im, SAFET'YDEPr 0 r) r-,.,... _ ZIP- 0FOR Cp S� VE EnergyPro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-11-27711:47:21 ID: 'p 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date 29th Street Citrus Project LLC ❑ Multi Family ❑ Existing+ Addition/Alteration 1111271201i ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.36 6.98 -2.62 Space Cooling 55.13 50.69 4.44 Fans 11.02 13.24 -2.22 Domestic Hot Water 9.93 7.64 2.28 Pumps 0.00 0.00 0.00 Totals 80.44 78.56 1.88 Percent Better Than Standard: 2.3 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: , 1.00 (E) 1,200 138 Fuel Available at Site: Natural Gas (S) 820 154 Raised Floor Area: 0 (tn9 1,420 350 Slab on Grade Area: 3,675 (N) 870 101 Average Ceiling Height: 10.9 Roof 3,675 0 Fenestration Average U -Factor: 0.55 TOTAL: 743 Average SHGC: 0.23 Fenestration/CFA Ratio: 20.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 11/17 013 Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker Cily/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Sin Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) CITE �UILDI ®& QillitilT` Company SAFETY Address Name —, DEPT -rY d �� R Y City/State/Zip Phone Signed F0 CCLic Rf EE) wry Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-11-27T11:47:21 ID"' Page 5 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name 29th Street Citrus Project LLC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/27/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Tilt I Status Joint Appendix 4 Location/Comments Wall 668 0.069 R-21 90 90 1 New 4.3.1-A6 Whole House Wall 376 0.069 R-21 180 90 New 4.3.1-A6 Whole House Wall 694 0.069 R-21 270 90 New 4.3.1-A6 Whole House Wall 458 0.069 R-21 0 90 New 4.3.1-A6 Whole House Roof 3,335 0.025,R-38 90 0 New 4.2.1-A21 Whole House Slab 2,335 0.730 None 0 180 New 4.4.7-A1 Whole House Slab 1,000 0.730 None 0 180 New 4.4.7-A1 Whole House Wall 394 0.069 R-21 90 90 New 4.3.1-A6 Casita Wall 290 0.069 R-21 180 90 New 4.3.1-A6 Casita Wall 376 0.069 R-21 270 90 New 4.3.1-A6 Casita Wall 311 0.069 R-21 0 90 New 4.3.1-A6 Casita Roof 340 0.025 R-38 90 0 New 4.2.1-A21 Casita Slab 100 0.730 None 0 180 New 4.4.7-A1 Casita Slab 240 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 18.0 0.480 1 NFRC 0.25 1 NFRC 90 New Window 1 Whole House 2 Window 18.0 0.480 NFRC 0.25 NFRC 90 New Window 1 Whole House 3 Window 64.0 0.610 NFRC 0.21 NFRC 90 New Sliding Door Whole House 4 Window 32.0 0.480 NFRC 0.25 NFRC 90 New Window 1 Whole House 5 Window 64.0 0.610 NFRC 0.21 NFRC 180 New Sliding Door Whole House 6 Window 18.0 0.480 NFRC 0.25 NFRC 180 New Window 1 Mole House 7 Window 18.0 0.480 NFRC 0.25 NFRC 180 New Window 1 Whole House 8 Window 24.0 0.480 NFRC 0.25 NFRC 180 New Window 1 Whole House 9 Window 10.0 0.480 NFRC 0.25 NFRC 270 New Window 1 Whole House 10 Window 6.3 0.480 NFRC 0.25 NFRC 270 New Window 1 Whole House 11 Window 10.0 0.480 NFRC 0.25 NFRC 270 New Window 1 Whole House 12 Window 6.3 0.480 NFRC 0.25 NFRC 270 New Window 1 Whole House 13 Window 10.0 0.480 NFRC 0.25 NFRC 270 New Window 1 Whole House 14 Window 6.3 0.480 NFRC 1 0.25 1 NFRC 270 New Window 1 Whole House 15 Window 192.0 0.610 NFRC 0. 211 NFRC 2701 New Sliding Door Whole House 16 Window 15.0 0.480 NFRC 0.25 1 NFRC 2701 New Window 1 Whole House (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2) SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len I H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 6.0 3.0 2.01 0.1 2.0 2.0 2 Bug Screen 0.76 6.0 3.0 2.01 0.1 2.0 2.0 3 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 8.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.01 3.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 6.01 3.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 4.0 2.5 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 2.5 2.5 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 4.0 2.5 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 2.5 2.5 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 4.0 2.5 2.0 0.1 2.0 2.0 1 t- 1 (i ; 1 .1 14 Bug Screen 0.76 2.5 2.5 2.0 0.1 2.0 2.0 81111 15 Bug Screen 0.76 &01 4.0 16.0 0.1 16.0 16.0 16 Bug Screen 1 0.76 6.01 2.5 2.0 0.1 2.0 2.0 /C: !� 1-- .- _ _ LCf✓ FOR CONS AUC C� Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-11-27711:47:21 N ID: Pae of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name 29th Street Citrus Project LLC Building Type m Single Family ❑ Multi Family ❑ Addition Alone ❑ Existing+ Addition/Alteration Date 11112712013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Ca\(ityTExterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 15.0 0.480 NFRC 0.25 NFRC 270 New Window 1 Whole House 18 Window 15.0 0.480 NFRC 0.25 NFRC 270 New Window 1 Mole House 19 Window 15.4 0.480 NFRC 0.25 NFRC 0 New Window 1 Whole House 20 Window 15.4 0.480 NFRC 0.25 NFRC 0 New Window 1 Whole House 21 Window 6.3 0.480 NFRC 0.25 NFRC 0 New Window 1 Whole House 22 Window 25.0 0.480 NFRC 0.25 NFRC 0 New Window 1 Whole House 23 Window 6.0 0.480 NFRC 0.25 NFRC 90 New Window 1 Casita 24 Window 15.0 0.480 NFRC 0.25 NFRC 180 New Window 1 Casita 25 Window 15.0 0.480 NFRC 0.25 NFRC 180 New Window 1 Casita 26 Window 64.0 0.610 NFRC 0.21 NFRC 270 New Sliding Door Casita 27 Window 15.0 0.480 NFRC 0.25 NFRC 0 New Window 1 Casita 28 Window 24.0 0.480 NFRC 0.25 NFRC 0 New Window i Casita (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Len H t LEA I RExt Left Fin Ri ht Fin Dist Len H t Dist Len H t 17 Bug Screen 0.76 6.0 2.5 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 6.0 2.5 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 5.0 3.2 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 5.0 3.2 3.0 0.1 3.0 3.0 21 Bug Screen 0.76 1.4 5.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 27 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 28 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 Ulf- II (,r- _yq Ain � � (.)I II aI-rA FpR C� S RVED Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-11-27711:47:21 I ID: a e 7 of 13 oArE �_ eY CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name 29th Street Citrus Project LLC Building Type IZI Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11/27/201 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Whole House Whole House 3,335 36,685 Casita Casita 340 3,400 Totals 1 3,6751 01 01 01 1 HVAC SYSTEMS System Name Qty. I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Whole House 2 IcentralFurnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New Casita 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R-Value Tested? Status Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New Casita Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Rinnai R94LS 1 Instant Gas No Pipe Insulation 165,000 0 0.81 n/a n/a New Rinnai R94LS 1 Instant Gas No Pipe Insulation 165,000 0 0.81 n/a n/a New MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C: 0 is 0 U) Q System Name— "— Pipe —Leenn-.th= Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ r r t A i I_ , A--�-... 0E31 r►�"," '_ QUINT , ❑ o, V� ck JAFE-rY ❑ 1 ►'-1 rN11"- Y ❑ .v I=CJ Y "L)U NON Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-11-27711:47:21 1 ID:,- Pae 8 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 'of 3 MF -1 R Project Name Date 29th Street Citrus Project LLC 11/27/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF- I R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent 1 -1 -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildin , are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation havingan installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture, equip, m-. eat jraintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retard ` r� s enc osetl entirely=in conditioned space. I 1I OF I ,Q, 01 o f �, �-„- e P. ills - �e��►v 150(j)4: Solar water-heatingsystems and/or collectors are certified b the Solar Ratingand Certifications COr, . prationti r_ r-,' , _ � �� �. i LJCF � , DEP IAPPROVED APPRO ED F rar�r,, EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-11-27711:47:21 N ID: v� V`7 f AUG g?Mf 13 DATE -_ BY MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date 29th Street Citrus Project LLC 11112712013 §150(m)l : All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tae shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)B: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. Lt Y OF LA QUiNTj BUILDING & SAFE TY DEP7 EnergyPro5.1 byEnergySoft User Number: 2655 RunCode:2013-11-27T11:47:21 IID: �UtV8TRI jPage�l0,of13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date 29th Street Citrus Project LLC 11/27/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with fou-r_or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that theV are controlled by an occupant sensors certified to comply with the applicable requirements of 119. OF LA QUIN1G & SAFETY DE PROVED ONSTRUCTION r EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-11-27711:47:21 hP-'QATP Page 11 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date 29th Street Citrus Project LLC 11/27/2013 System Name Floor Area Whole House 3,335 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,316 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 31,405 2,882 1,030 37,713 Total Output Btuh 142,000 0 Output Btuh/s ft 42.6 1,813 1,853 Cooling System 0 0 Output per System 40,000 0 0 0 0 Total Output Btuh 80,000 0 2,882 0 Total Output Tons 6.7 1,813 1,853 Total Output Btuh/s ft 24.0 Total Output s ft/Ton 500.3 35,0317 41,419 Air System CFM per System 1,500 HVAC EQUIPMENT SELECTION Airflow cfm 3,000 BDP CO. 561AJ042-- 60,484 8,082 142,000 Airflow cfm/s ft 0.90 Airflow cfm/Ton 450.0 Outside Air (%) 0.0% Total Adjusted System Output 60,484 8,082 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM 1 142,000 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 69 OF 69 OF 105 OF - Outside Air 0 cfm Supply Fan Heating Coil 104 OF 3,000 cfm — G ROOM 69 OF 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112 / 78 OF 79 / 63 IF 79 / 63 OF 55 / 54 OF Outside Air Ar 0 Supply Fan cfm Cooling Coil CITY 3,000 cfm 7 _, Q 42.2% B ..... �FE 79 / 63 OF APPROVE --' TRUCI EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-11-27711:47:21 ID: ---Pag JINTA 'DEPT. D ION HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date 29th Street Citrus Project LLC 11/27/2013 System Name Floor Area Casita 340 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 308 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD I COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 53,000 7,444 412 325 11,976 Total Output Btuh 53,000 0 Output Btuh/s ft 155.9 430 589 Cooling System 0 0 Output perSystem 29,000 0 0 0 0 Total Output Btuh 29,000 0 412 0 Total Output Tons 2.4 4301 589 Total Output Btuh/s ft 85.3 Total Output s ft/Ton 140.7 8,304 13,153 Air System CFM perSystem 1,300 HVAC EQUIPMENT SELECTION Airflow cfm 1,300 BDP CO. 561AJ030-' 21,593 3,144 53,000 Airflow (cfm/s ft) 3.82 Airflow cfm/Ton 537.9 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 21,593 3,144 Aug 3 PM 53,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 70 OF 70 OF 105 OF Outside Air — 0 cfm Supply Fan Heating Coil 105 OF AIL 1,300 cfm ROOM 70 OF 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112 / 78 OF 78 / 62 OF 78 / 62 OF 55 / 54 OF --- . Outside Air — 0 cfm Supply Fan Cooling Coil 55 / 54 OF AL 1,300 cfm 1,%'Y1 41.5/0 �11X° 1%IY'� C U I t_ l l FE 78 / 62 OF 7.'s;2 4 14 lov - - ---9------ FOR CONSTRU EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-11-27T11:47:21 ID: Page 13 of 13 UINTA Y DEPT. eD TION P- 115 HFX-18x14 1641/4 1 118" HS 4,000 HFX-18x15 1761/4 3,500 HFX-18x16 1881/4 3,000 HFX-18x17 200114 2,500 HFX-18x18 2121/4 2,000 HFX-18x19 1 2241/4 2,000 HFX-18x20 1 2361/4 2,000 HFX-24x78 78 1 1/8" STD 1,000 3,500 6,500 1 1/8" HS 1,000 3,500 6 500 HFX-24x8 921/4 1 1/8" STD 1,000 3,500 6,500 11/8"HS 1,000 3,500 6 500 HFX-24x9 1041/4 1 1/8" STD 1,000 3,500 6,500 1 1/8" HS 1,000 3,500 6,500 HFX-24x10 1161/4 1 1/8" STD 1,000 3,500 6,500 1 1/8" HS 1,000 3,500 6 500 HFX-24x11 1281/4 1 1 /8"STD 1,000 3,500 6,500 1 1/8" HS 1,000 3,500 6 500 HFX-24x12 - 1401/4 1 1/8" STD 1 000 6 500 1 1/8" HS 1 000 3,500 6 500 HFX-24x13 1521/4 1 1/8" STD 1 000 3,500 6,500 1 1/8" HS 1,000 3,500 6,500 HFX-24x14 1641/4 H11/8" HS 4,000 HFX-24x15 1761/4 3 500 HFX-24x16 1881/4 3,000 HFX-24x17 2001/4 2,500 HFX-24x18 212114 2,000 HFX-24x19 2241 2,000 HFX-24x20 1 2361/4 2,000 ' HFX-32x8 921/4 7/8" STD 1,000 3,500 6,500 7/8" HS 1,000 3,500 6 500 18" Wide Panels Balloon Wall 1,380 0.642 18,473 1,310 0.701 18,937 1,250 0.760 19,433 1,195 0.824 19,888 1,150 0.887 20,455 1,105 0.953 20,885 1,070 1.020 21,489 24" Wide Panels 3,490 0.11 5,600 0.1 E 5,610 0.1E 5,605 0.1 E 3,080 0.1? 4,950 0.22 2,800 0.1 E 4,510 0.2E 2,580 0.1? 2,540 0.1? 4,145 0.2E 2,390 0.1E 2,350 O.1E 3,730 0.3C 2,230 0.21 2195 0.2 2,185 0.21 3,410 0.3" 2,085 0.24 2,050 0.2' 2,040 0.2' 3,140 0.3E 24" Wide Panels Balloon Wall 2,090 0.52 1,960 0.5E 1,825 0.62 1,695 0.6E 1,595 0.6E 1,515 0.7 1,460 0.7 32" Wide Brace Frames 2,225 0.1; 2,160 0.1� 1,360 0.01 3,000 0.ti 2,335 0.1: 1,540 0.04 1,960 0.913 32,447 1,830 0.979 32,584 1,715 1.046 32,654 1,615 1.113 32781 1,530 1.179 33,092 1,450 1.244 33,191 1,220 1 1.166 j 26,317 .1