Loading...
BRES2015-0414 Title 24j IY.. BUILDING ENERGY ANALYSIS REPORT I PROJECT: Perkel Residence Lots 37 & 38, The Hideaway La Quinta, CA 92253 Project Designer: Stracts Architects 550 S. Oleander Palm Springs, CA 92262 (760) 636-8951 Report Prepared by: Tim Scott Scott'Design and Title 24, Inc, ' ^ 77085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 12/17/2015 CITE' OF LA QUANTA BUILDING & SAFETY DEPT. AIT gVED FOR`CONS "RUCTION DATE f % The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is . authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. " EnergyPro 6.7 by EnergySoft User Number: 6712 /D: CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Perkel Residence Calculation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xml CF*RF-01 Page 1 of 15 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Perkel Residence 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location Lots 37 & 38, The Hideaway Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 6489 15 Number of Zones 6 16 Slab Area (ft2) 5024 17 Number of Stories 2 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) N/A 21 Glazing Percentage (%) 24.4% COMPLIANCE RESULTS 01 Building Complies with Computer Performance h 02 This building incorporates features that require field testing and/or verification by a certified HERS later under the supervision of a CEC-approved HERS provider. 1 1 tiw FA -0 f J A %-ar V t LOF I A Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 7.02 5.45 1.57 22.4% Space Cooling 143.87 131.76 12.11 8.4% IAQ Ventilation 1.43 1.43 0.00 0.0% Water Heating 3.96 4.53 -0.57 -14.4% Photovoltaic Offset -- 0.00 0.00 -- Compliance Energy Total 156.28 143.17 13.11 8.4% Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIF0E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE giOD Project Name: Perkel Residence Calculation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY CFORF-01 Page 2 of 15 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: — None -- 0 I //' Ii it ti} l) I ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for_energy use components included in the performance compliance approach for the Starid'ard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer, electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. `� 'i I � I-% _> r- V_ V V # V L- " 02 Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDVlf2-yr)' 191.68 178.57 13.11 6.8% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Perkel Residence 6489 1 18 6 0 1 Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIFpame: E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD Project Perkel Residence Calculation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xm1 CF•RF-01 Page 3 of 15 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 master Zone Conditioned HVAC 11 1540 9 DHW Sys 1 grt liv kit Zone Conditioned HVAC 2 & 32 2634 9 DHW Sys 1 bed 3 Conditioned HVAC .13 425 9 DHW Sys 1 bed 2 Conditioned HVAC .24 425 9 DHW Sys 1 2 fir office Conditioned HVAC5 355 9 DHW Sys 1 2 fir media Conditioned HVAC 56 1110 9 DHW Sys 1 Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 HERS PROVIDER Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Perkel Residence ation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xml CFORF-01 Page 4 of 15 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Wall master Zone R-21 Wall (W.19.2x6.16) 0 Front 756 104 90 E Wall master Zone R-21 Wall (W. 19.2x6.16) 90 Left 506 90 S Wall master Zone R-21 Wall (W.19.2x6.16) 180 Back 506 90 W Wall master Zone R-21 Wall (W.19.2x6.16) 270 Right 1092 67.6 90 R-38 Roof master Zone R-38 Roof(R.38.2x14.16) 1540 N Wall 2 grt liv kit Zone R-21 Wall (W.19.2x6.16) 0 Front 1500 391 90 E Wall 2 grt liv kit Zone R-21 Wall (W.19.2x6.16) 90 Left 1500 111.6 90 S Wall 2 grt liv kit Zone R-21 Wall (W.19.2x6.16) 180 Back 1500 245 90 W Wall 2 grt liv kit Zone R-21 Wall (W. 19.2x6.16) 270 Right 950 72 90 R-38 Roof 2 grt liv kit Zone R-38 Roof(R.38.2x14.16) 2634 N Wall 3 bed 3 R-21 Wall (W.19.2x6.16) 0 Front 500 43 90 E Wall 3 bed 3 R-21 Wall (W.19.2x6.16) 90 Left 650 30 90 S Wall 3 bed 3 _ R -21 -Wall (W19.2x6.16)\ 'f180 i _Back 500 23 90 W Wall 3 bed 3 , . R-21 Wall (W.19.2x6.16) 270 JRight ' 650 40 90 R-38 Roof 3 bed 3',, ' ' ^ IR -38 Roof(R.38.2x14.16) - � jj U Lr � J `� t r 425 N Wall 4 bed 2 R-21 Wall (W.19.2x6.16) '. 107 Front 250 43 90 E Wall 4 bed 2 R-21 Wall (W.19.2x6.16) 90 Left 650 40 90 S Wall 4 bed 2 R-21 Wall (W.19.2x6.16) 180 Back 500 23 90 W Wall 4 bed 2 R-21 Wall (W.19.2x6.16) 270 Right 650 30 90 R-38 Roof 4 bed 2 R-38 Roof(R.38.2x14.16) 425 N Wall 5 2 flr office R-21 Wall (W. 19.2x6.16) 0 Front 448 110 90 E Wall 5 2 fir office R-21 Wall (W.19.2x6.16) 90 Left 448 10 90 S Wall 5 2 fir office R-21 Wall (W.19.2x6.16) 180 Back 448 10 90 W Wall 5 2 fir office R-21 Wall (W.19.2x6.16) 270 Right 448 50 90 R-38 Roof 5 2 fir office R-38 Roof(R.38.2x14.16) 355 N Wall 6 2 fir media R-21 Wall (W.19.2x6.16) 0 Front 650 92 90 E Wall 6 2 fir media R-21 Wall (W.19.2x6.16) 90 Left 850 30.6 90 S Wall 6 2 fir media R-21 Wall (W.19.2x6.16) 180 Back 650 52 90 W Wall 6 2 flr media R-21 Wall (W.19.2x6.16) 270 Right 850 12 90 R-38 Roof 6 2 fir media R-38 Roof(R.38.2x14.16) 1110 Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIFJOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Perkel Residence Cr* culation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xml CFORF-01 Page 5 of 15 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic master Zone Attic Roofmaster Zone Ventilated 3 0.1 0.85 No No Attic grt liv kit Zone Attic Roofgrt liv kit Zone Ventilated 3 0.1 0.85 No No Attic bed 3 Attic Roofbed 3 Ventilated 3 0.1 0.85 No No Attic bed 2 Attic Roofbed 2 Ventilated 3 0.1 0.85 No No Attic 2 flr office Attic Roof2 flr office Ventilated 3 0.1 0.85 No No Attic 2 flr media Attic Roof2 flr media Ventilated 3 0.1 0.85 No No HERS PR Zz } +IC>EHR Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIF* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD Project Name: Perkel Residence Calculation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xm1 CFIDRF-01 Page 6 of 15 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U -factor SHGC Exterior Shading 15 Window N Wall (Front -0) --- -- 1 24.0 0.32 0.29 Insect Screen (default) 13 Window N Wall (Front -0) --- -- 1 80.0 0.32 0.29 Insect Screen (default) J Window W Wall (Right -270) -- -- 1 40.0 0.32 0.29 Insect Screen (default) 14 Window W Wall (Right -270) --- -- 1 21.6 0.32 0.29 Insect Screen (default) H Window W Wall (Right -270) -- -- 1 6.0 0.32 0.29 Insect Screen (default) 12 Window N Wall 2 (Front -0) --- -- 1 295.0 0.32 0.29 Insect Screen (default) 11 Window N Wall 2 (Front -0) -- --- 1 96.0 0.32 0.29 Insect Screen (default) G Window E Wall 2 (Left -90) --- -- 1 30.0 0.32 0.29 Insect Screen (default) 9 Window E Wall 2 (Left -90) --- -- 1 21.6 0.32 0.29 Insect Screen (default) 22 Window E Wall 2 (Left -90) -- -- 1 20.0 0.32 0.29 Insect Screen (default) 21 Window E Wall 2 (Left -90) --- -- 1 40.0 0.32 0.29 Insect Screen (default) 3 Window S Wall 2 (Back -180) , _ 7 r +; y14_--_ _ - -- 1 80.0 0.32 0.29 Insect Screen (default) 1 WindowS Wall 2 (Back -180) E ; J - \ -_ +"11, -120.0 0.32 0.29 Insect Screen (default) T Window l ` S Wall 2 (Back`180) �s 7 - 6A 0.32 0.29 Insect Screen (default) N Windowl S Wal2 Back=180 x , Z _ ( ) 0 � -R=~ -�- f- 1_" "'y15.0 0.32 0.29 Insect Screen (default) 2 Window W Wall 2 (Right -270) -- -- 1 24.0 0.32 0.29 Insect Screen (default) M Window W Wall 2 (Right -270) --- -- 1 8.0 0.32 0.29 Insect Screen (default) L Window W Wall 2 (Right -270) --- -- 1 8.0 0.32 0.29 Insect Screen (default) K Window W Wall 2 (Right -270) --- -- 1 8.0 0.32 0.29 Insect Screen (default) FF Window N Wall 3 (Front -0) --- -- 1 1.0 0.32 0.29 Insect Screen (default) EE Window N Wall 3 (Front -0) -- -- 1 1.0 0.32 0.29 Insect Screen (default) DD Window N Wall 3 (Front -0) --- -- 1 1.0 0.32 0.29 Insect Screen (default) 4 Window N Wall 3 (Front -0) --- --- 1 40.0 0.32 0.29 Insect Screen (default) CC Window E Wall 3 (Left -90) --- --- 1 1.0 0.32 0.29 Insect Screen (default) BB Window E Wall 3 (Left -90) -- -- 1 1.0 0.32 0.29 Insect Screen (default) AA Window E Wall 3 (Left -90) --- -- 1 1.0 0.32 0.29 Insect Screen (default) Z Window E Wall 3 (Left -90) -- -- 1 1.0 0.32 0.29 Insect Screen (default) Y Window E Wall 3 (Left -90) --- -- 1 1.0 0.32 0.29 Insect Screen (default) D Window E Wall 3 (Left -90) -- -- 1 12.5 0.32 0.29 Insect Screen (default) Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIF� OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project ame: Perkel Residence Ca culation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xml CFF -01 Page 7 of 15 C Window E Wall 3 (Left -90) --- -- 1 12.5 0.32 0.29 Insect Screen (default) V Window S Wall 3 (Back -180) --- --- 1 1.0 0.32 0.29 Insect Screen (default) W Window S Wall 3 (Back -180) --- - 1 1.0 0.32 0.29 Insect Screen (default) x Window S Wall 3 (Back -180) --- - 1 1.0 0.32 0.29 Insect Screen (default) B Window S Wall 3 (Back -180) -- - 1 10.0 0.32 0.29 Insect Screen (default) A Window S Wall 3 (Back -180) -- - 1 10.0 0.32 0.29 Insect Screen (default) 5 Window W Wall 3 (Right -270) -- - 1 40.0 0.32 0.29 Insect Screen (default) KK Window N Wall 4 (Front -0) ---- -- 1 1.0 0.32 0.29 Insect Screen (default) JJ Window N Wall 4 (Front -0) --- -- 1 1.0 0.32 0.29 Insect Screen (default) HH Window N Wall 4 (Front -0) -- -- 1 1.0 0.32 0.29 Insect Screen (default) 20 Window N Wall 4 (Front -0) --- - 1 40.0 0.32 0.29 Insect Screen (default) 19 Window E Wall 4 (Left -90) --- -- 1 40.0 0.32 0.29 Insect Screen (default) TT Window S Wall 4 (Back -180) -- -- 1 1.0 0.32 0.29 Insect Screen (default) SS Window S Wall 4 (Back -180) --- -- 1 1.0 0.32 0.29 Insect Screen (default) RR Window S Wall 4 (Back -180) --- -- 1 1.0 0.32 0.29 Insect Screen (default) R Window S Wall 4'(Back-180) -� " ,y: -=i "f '� -- i' 1 10.0 0.32 0.29 Insect Screen (default) S Window �, S Wall 4 (Back -180) , ;_ ' --' -- ' 1'1 1 '10.0 0.32 0.29 Insect Screen (default) QQ Window ` \1 W Wall 4 (Right -270) ` ' _ a i.' �- ---- C �� =- L ,: 1'.; ` `--1.0 0.32 0.29 Insect Screen (default) PP Window `'� W Wall 4 (RigF t-270)? :; r> zz n ' ,h + r j ,1- 1.0 0.32 0.29 Insect Screen (default) NN Window W Wall 4 (Right -270) --- -- 1 1.0 0.32 0.29 Insect Screen (default) MM Window W Wall 4 (Right -270) --- -- 1 1.0 0.32 0.29 Insect Screen (default) LL Window W Wall 4 (Right -270) -- -- 1 1.0 0.32 0.29 Insect Screen (default) Q Window W Wall 4 (Right -270) --- - 1 12.5 0.32 0.29 Insect Screen (default) P Window W Wall 4 (Right -270) ---- -- 1 12.5 0.32 0.29 Insect Screen (default) AF Window N Wall 5 (Front -0) -- -- 1 30.0 0.32 0.29 Insect Screen (default) 44 Window N Wall 5 (Front -0) -- - 1 80.0 0.32 0.29 Insect Screen (default) AE Window E Wall 5 (Left -90) ---- - 1 10.0 0.32 0.29 Insect Screen (default) AD. Window S Wall 5 (Back -180) -- - 1 10.0 0.32 0.29 Insect Screen (default) AJ Window W Wall 5 (Right -270) - -- 1 10.0 0.32 0.29 Insect Screen (default) AH Window W Wall 5 (Right -270) ---- -- 1 30.0 0.32 0.29 Insect Screen (default) AG Window W Wall 5 (Right -270) ---- -- 1 10.0 0.32 0.29 Insect Screen (default) 43 Window N Wall 6 (Front -0) --- -- 1 80.0 0.32 0.29 Insect Screen (default) AB Window N Wall 6 (Front -0) ---- - 1 12.0 0.32 0.29 Insect Screen (default) Registration Number: 215-N63085618-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Perkel Residence Calculation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xm1 CORF-01 Page 8 of 15 ZZ Window E Wall 6 (Left -90) --- -- 1 6.0 0.32 0.29 Insect Screen (default) YY Window E Wall 6 (Left -90) --- -- 1 6.3 0.32 0.29 Insect Screen (default) XX Window E Wall 6 (Left -90) ---- -- 1 6.3 0.32 0.29 Insect Screen (default) WW Window E Wall 6 (Left -90) --- — 1 12.0 0.32 0.29 Insect Screen (default) VV Window S Wall 6 (Back -180) ---- — 1 6.0 0.32 1 0.29 Insect Screen (default) UU Window S Wall 6 (Back -180) ---- -- 1 6.0 0.32 0.29 Insect Screen (default) 42 Window S Wall 6 (Back -180) --- -- 1 40.0 0.32 0.29 Insect Screen (default) AC Window W Wall 6 (Right -270) --- -- 1 12.0 0.32 0.29 Insect Screen (default) DOORS 01 02 03 04 Name Side of Building Area (ft) U -factor 23 S Wall 2 24.0 0.50 34 W Wall 2 24.0 0.50 C E MTS, c. HERS PROVIDER Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Perkel Residence Ca culation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xml CFORF-01 Page 9 of 15 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers master Zone 1540 125 None 0.8 No • Cavity/ Frame: no insul. / 2x4 Top Chrd grt liv kit Zone 2634 245 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic Roofmaster Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) bed 2 425 80 None 0.8 No • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof(R.38.2x14.16) attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 • Exterior Finish: Wood R-21 Wall (W.19.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgrt liv kit Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofbed 3 Attic Roofs Wood Framed Ceiling: , in. O.C,'=_�, ,.l none 0.644 Roofing: Light Roof (Asphalt Shingle) r�� 2x4 To Chord of Roof Truss 24 Cavity/ Frame: no insul. / 2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking -,U Wood p 1 `@ { J� none' j Attic Roofbed 2 Attic Roofs Framed Ceiling in.-O.C. w 0.644 Roofing: Light Roof As halt Shingle) 9� 9 ( P 9 ) F K tj► f T L Cavity /Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2 fir office Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2 fir media Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Slab master Zone 1540 125 None 0.8 No Slab 2 grt liv kit Zone 2634 245 None 0.8 No Slab 3 bed 3 425 80 None 0.8 No Slab 4 bed 2 425 80 None 0.8 No Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Perkel Residence Calculation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xml BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required — CORF-01 Page 10 of 15 WATER HEATING SYSTEMS 01 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/2 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 75 0.65 65000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION ^ l\ �` 1 ,' 4 - 1 j �� j r –)) ,--, 11 i i 1 i l l 01 02_� 03. - 04 { - l05 06 07 Name Pipe Insulation Parallel Piping V ! LJ Compact Distribution Y-: Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/2 -- – — -- -- — SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC 11 Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 System HVAC 2 & 32 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC5 Other Heating and Cooling Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 System HVAC 56 Other Heating and Cooling Heating Component 6 Cooling Component 6 HVAC Fan 6 Air Distribution System 6 System Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Perkel Residence Calculation Daterrime: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xml CFORF-01 Page 11 of 15 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name :Heat Pump System 3:::2 Heat Pump Heating and Cooling System Heat Pump System 3 Heat Pump System 3 None None :Heat Pump System 4:::2 Heat Pump Heating and Cooling System Heat Pump System 4 Heat Pump System 4 None None HVAC - HEATING UNIT TYPES 01 <-02 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 5 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 6 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - HEAT PUMPS 01 <-02 04 05 ), 06 3 07 �. , ,08 09 10 Name Type Heating -HSPF/COP Cap 47 Cap 17 'Cooling ,, SEER EER Zonally ' Controlled Multispeed Compressor HERS Verification Heat Pump System 3 Ductless HeatPump 8.3 38000 34000 13.1 11 No No Heat Pump System 3 -hers -cool Heat Pump System 4 DuctlessHeatPump 8.3 38000 34000 13.1 11 No No Heat Pump System 4 -hers -cool Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Perkel Residence Ca culation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xmi CFGF-01 Page 12 of 15 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 02 ; ;' r Z Efficiency d ice` 04' Multi -speed 06 Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1 -hers -cool Cooling Component 2 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1 -hers -cool Required DuctlessHeatPump 11 13.1 Not Zonal Single Speed Cooling Component 1 -hers -cool 350 DuctlessHeatPump 11 13.1 Not Zonal Single Speed Cooling Component 1 -hers -cool Cooling Component 5 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1 -hers -cool Cooling Component 6 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1 -hers -cool HVAC COOLING - HERS VERIFICATION �- -� r- I r-- -_ s r r - 01 02 ; ;' r Z ! 03. jJ d ice` 04' 05 06 Name Verified Airflow _ Airflow Target_ '7 3 j ! i f Verified EER _ -tf Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required rel 1 l -t —'R 350" n 1. Required E' • Required Required Cooling Component 2 -hers -cool Required 350 Required Required Required Cooling Component 5 -hers -cool Required 350 Required Required Required Cooling Component 6 -hers -cool Required 350 Required Required Required Heat Pump System 3 -hers -cool Not Required Not Required Not Required Not Required Heat Pump System 4 -hers -cool Not Required Not Required Not Required Not Required Registration Number: 215-N6306561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIFJOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project ame: Perkel Residence Ca culation DatelTime: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xm1 C*RF-01' Page 13 of 15 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System Not Required Not Required — Air Distribution System 2 -hers -dist Required 6.0 _ 1 -hers -dist Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System Not Required Not Required { Not'Required Not Required -- Air Distribution System 6 -hers -dist 2 -hers -dist 6.0 Not Required Not Required Not Required no ducts None no ducts None Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 5 -hers -dist Air Distribution System 6 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 6 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification r _ Duct Leakage _ Target (%) Verified Duct Location Verified Duct Design Buried "Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required`ti r 6.0 Not Required Not Required Not Required Not Required — Air Distribution System 2 -hers -dist Required 6.0 _ Not Required _ Not Required Not Required Not Required -- Air Distribution System 5 -hers -dist Required 6.0 ' - r Not Required Not Required { Not'Required Not Required -- Air Distribution System 6 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required — HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5 -hers -fan HVAC Fan 6 Single Speed PSC Furnace Fan 0.58 HVAC Fan 6 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 00013 Project Name: Perkel Residence Calculation Date/Time: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xm1 CFORF-01 Page 14 of 15 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan Required 0.58 HVAC Fan 5 -hers -fan Required 0.58 HVAC Fan 6 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 207.39 0.25 Default 0 Required Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 rrzi En j 1 C O U HERS PROVIE ER Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Perkel Residence Ca culation DatefTime: 07:56, Thu, Dec 17, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lots 37 & 38-Perkel-Stracts-15.xm1 CF&RF-01 Page 15 of 15 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Z;V-57co&i Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2015-12-17 09:26:24 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval.with this building permit application. Responsible Designer Name: r' ; i" Responsible Designer Signature:, Tim Scott Company:t E R S P HERS i� Q Da�te�, Signed: "l r 2015-12-17 09:26:24'' ER Scott Design and Title 24, Inc. Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N6308561B-000000000-0000 Registration Date/Time: 2015-12-17 09:26:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 07:58:44 • • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Perkel Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 12/17/2015 Project Address Lots 37 & 38, The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,489 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity ft Special Features Status Roof Wood Framed Attic R38 6,489 New Wall Wood Framed R 21 15,822 New Slab Unheated Slab -on -Grade - no insulation 5,024 Perim = 530' New Demising Wood Framed - no insulation 3,113 New Door Opaque Door - no insulation 48 New FENESTRATION Total Area: 1,582 Glazin Percentage: 24.4 %New/Altered Average U -Factor: 0.32 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Front (N) 783.0 0.320 0.29 none none Bug Screen New Right (tM 247.6 0.320 0.29 none none Bug Screen New Left (E) 222.2 0.320 0.29 none none Bug Screen New Rear (S) 329.0 0.320 0.29 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Split Heat Pump 8.30 HSPF Split Heat Pump 13.1 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic 8.0 New HVAC 2 & 3 Ducted Ducted Attic 8.0 New HVAC .1 Ductless/ with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Storage Gas 75 0.65 All Pipes Ins New EnerqvPro 6.7 by Ene Soft User Number: 6712 Run Code: 2015-12-17T09:17:10 ID: Pae 18 of 51 • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Perkel Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 11211712015 Date Project Address Lots 37 & 38, The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,489 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION I Total Area: 1582 Glazing Percentage: 24.4 o New/Altered Average U -Factor: 0.32 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.30 HSPF Split Heat Pump 13.1 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC .2 Ductless /with Fan Ductless n/a n/a New HVAC Ducted Ducted Attic 8.0 New HVAC 5 Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnenqyPro6.7 by Ene vSoft User Number: 6712 RunCode: 2015-12-17709:17:10 /D: Pae 19 of 51 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 1 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110 8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 1 10.8(1) when the installation of a cool roof is specified on the CF] R. §1 10.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. .0(c): §150factor). Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U- § I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §I50.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of §I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §I50.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)IC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § I50.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 1 10.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 1 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 1 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. I50.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in§150.Oh2. § I50.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c). §150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)26: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 4 4 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § I50.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)36: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § I50.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § I50.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 1 10.3(c)5. §I50.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 FIVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §I50.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § I50.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(,)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § I50.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § I50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § I50.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)1 l: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m) 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. 'rhe §I50.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §I50.0(o)I A: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance .with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency §1 10.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. In 4 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. §I 10.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §1 10.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. §110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § I50.0(p): Residential pool systems or equipment shall meet specified pump sizing, now rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. § 150.0(k) I B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §I50.0(k)IC: §I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § 150.0(k)l D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §I50.0(k)I E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night Iights do not need to be controlled by vacancy sensors. §I50.0(k)I F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § I50.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § I50.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § I50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in $110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 4 2013 Low -Rise Residential Mandatory Measures Summary 0 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. §I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in $110.9, $130.0, $130.2, §130.4, §140.7 and §141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §I50.0(k)l0: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for ' nonresidential garages in § 110.93 § 130.0, 130. 1, § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § I 50.0(k) I 2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an Occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §I50.0(k)1213: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §1 10.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January I, 2014, shall comply with the requirements of §110.10 b through §110.10(e). §I 10.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §I 10.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. §110.10(6)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. §1 10.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 1 10.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 1 10.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. §110. 1 0(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 1 10.10(c) shall be provided to the occupant. § 110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 1 10.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". 0 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name erkel Residence Date 12/17/2015 System Name HVAC 1 Floor Area 1,540 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 887 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 18,432 1,955 485 21,184 Total Output Btuh 89,000 0 Output Btuh/s ft 57.8 868 809 Cooling System 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 58,000 0 1,955 0 Total Output Tons 4.8 868 809 Total Output Btuhls ft 37.7 Total Output s ft/Ton 318.6 20,168 22,802 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760/58CVX110 43,315 6,388 89,000 Airflow cfm/s ft 1.30 Airflow cfm/Ton 413.8 Outside Air % 0.0% Total Adjusted System Output 43,315 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 6,388 Aug 3 PM 89,000 F Jan 1 AM Outside Air cfm/s fc 0.00 ote: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 72 OF Outside Air 0 cfm Supply Fan 2,000 cfm 72 OF 72 OF 113 OF Heating Coil 113 OF ROOM I�I 72 OF_LU COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F 76/63°F 76/63°F 56/55°F Outside Air Ar 0 cfm Supply Fan Cooling Coil 56 / 55 OF 2,000 cfm 47.5% ROOM 76 / 63 OF 76/ 63 OF EnergyPro 6.7 by Energy oft User Number., 6712 RunCode: 2015-12-17T09:17:10 /D: Page 24 of 51 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name erkel Residence Date 12/17/2015 System Name HVAC 2 & 3 Floor Area 2,634 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,975 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 41,099 3,343 1,043 45,525 Total Output Btuh 178,000 0 Output Btuh/s ft 67.6 1,937 1,738 Cooling System 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 116,000 0 3,343 0 Total Output Tons 9.7 1,937 1,738 Total Output Btuh/s ft 44.0 Total Output s ft/Ton 272.5 1 44,972 1 49,000 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 Carrier 24ANB760/58CVX110 87,101 12,190 178,000 Airflow cfm/s ft 1.52 Airflow cfm/Ton 413.8 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 87,101 12,190 Aug 3 PM 178,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF 72 OF Outside Air 0 cfm Supply Fan 4,000 cfm 72 OF 72 OF 113 OF ��I —1- Heating Coil 113 OF ROOM Fq] 72 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112/78°F 76/63°F^� 76/63°F 56/55°F Outside Air 0 cfm Supply Fan Cooling Coil 4,000 cfm 76/63°F 0 LLU= 56 / 55 OF 47.2% ROOM 76/62°F ' EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17T09:17:10 ID: Page 25 of 51 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name erkel Residence Date 12/17/2015 System Name HVAC .1 Floor Area 425 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 339 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 38,000 10,377 539 495 13,193 Total Output Btuh 38,000 0 Output Btuh/s ft 89.4 0 0 Cooling System 0 0 Output perSystem 34,200 0 0 0 0 Total Output Btuh 34,200 0 539 0 Total Output Tons 2.9 1 0 0 Total Output Btuh/s ft 80.5 Total Output s ft/Ton 149.1 1 10,377 13,193 Air System CFM per System 890 HVAC EQUIPMENT SELECTION Airflow cfm 890 Mitsubishi Ductless Split 27,248 0 23,734 Airflow cfm/s ft 2.09 Airflow cfm/Ton 312.3 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 27,248 0 Aug 3 PM 23,734 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 97 OF 97 OF Heating Coil Supply Fan 890 cfm 97 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F Outside Air Ar 0 cfm 76 / 58 OF 76/58°F 47/46°F 47/46°F 7 U=13 Cooling Coil Supply Fan 47 / 46 OF 890 cfm 32.8% ROOM 76/ 58 OF EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17709:17:10 /D: Page 26 of 51 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Perkel Residence Date 12/17/2015 System Name HVAC .2 Floor Area 425 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 326 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 38,000 9,981 539 465 12,399 Total Output Btuh 38,000 0 Output Btuh/s ft 89.4 0 0 Cooling System 0 0 Output per System 34,200 0 0 0 0 Total Output Btuh 34,200 0 539 0 Total Output Tons 2.9 0 0 Total Output Btuh/s ft 80.5 Total Output s ft/Ton 149.1 9,981 12,399 Air System CFM per System 890 HVAC EQUIPMENT SELECTION Airflow cfm 890 Mitsubishi Ductless Split 27,248 0 23,734 Airflow cfm/s ft 2.09 Airflow cfm/Ton 312.3 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 27,248 0 23,734 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm A 72 OF 720F 970F 97 OF Heating Coil Supply Fan 890 cfm 97 OF 11=1 ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 76 / 58 OF 76 / 58 OF 47 / 46 OF 47 / 46 OF O Cooling Coil Supply Fan 890 cfm 47 / 46 OF -�^ 32.8% ROOM � kN . 76 / 58 OF EnergyPro 6.7 by EnergySoff User Number: 6712 RunCode: 2015-12-17709:17:10 /D: Page 27 of 51 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name erkel Residence Date 12/17/2015 System Name HVAC Floor Area 355 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 420 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 51,000 9,399 451 218 9,133 Total Output Btuh 51,000 0 Output Btuh/s ft 143.7 443 349 Cooling System 0 0 Output per System 35,500 0 0 0 0 Total Output Btuh 35,500 0 451 0 Total Output Tons 3.0 443 349 Total Output Btuh/s ft 100.0 Total Output s ft/Ton 120.0 10,285 9,830 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ANB736/58CVX070 27,748 2,183 51,000 Airflow cfm/s ft 3.38 Airflow cfm/Ton 405.6 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 27,748 2,183 51,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 ote: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF 72 OF Outside Air 0 cfm Supply Fan 1,200 cfm 72 OF 72 OF 112 OF V z Heating Coil I L 111 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 76/62°F 55/53°F Outside Air 0 cfm Supply Fan Cooling Coil 1,200 cfm 76 / 62 OF II U��1� 55 / 54 OF 44.1 % ROOM 76 / 62 OF EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 201 5-1 2-1 7 709:17:10 ID: Page 28 of 51 4 r L 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date erkel Residence 12/17/2015 System Name Floor Area HVAC 5 1,110 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM 755 0 Sensible Latent CFM Sensible Output perSystem 51,000 16,083 1,409 384 15,949 Total Output Btuh 51,000 0 Output Btuh/s ft 45.9 758 609 Cooling System 0 0 Output perSystem 35,500 0 0 0 0 Total Output Btuh 35,500 0 1,409 0 Total Output Tons 3.0 758 609 Total Output Btuh/s ft 32.0 Total Output s ft/Ton 375.2 17,599 17,167 Air System CFM erSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ANB736/58CVX070 27,089 3,211 51,000 Airflow cfm/s ft 1.08 Airflow cfm/Ton 405.6 51,000 Jan 1 AM Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 27,089 3,211 Aug EMI Outside Air cfm/s ft0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 72 OF 111 OF Outside Air 0 cfm Supply Fan Heating Coil 111 OF 1,200 cfm ROOM 72 OF 72 OF 4 Ape 4 -E-LU 4 COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F 77/62°F 77/63°F 55/54°F Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,200 cfm 46.4% ROOM 77/62°F 76/62°F _ _ EnergyPro 6.7 by EnergySoR User Number: 6712 Run Code: 201 5-12-1 7 70 9:17:10 ID: Page 29 of 51 • • ROOM LOAD SUMMARY Project Name Date Perkel Residence 12/17/2015 System Name Floor Area HVAC .1 425 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM Sensible I Latent CFM Sensible bed 3 1 Bedroom #3 1 1 1 3391 10,3771 539 339 10,3771 539 4951 13,193 PAGE TOTAL TOTAL' Total includes ventilation load 339 10,377 539 495 13,193 339 10,377 539 495 13,193 I EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 20 1 5-12-1 7 70 9:17:10 ID: Page 32 of 51 • ROOM LOAD SUMMARY Project Name Date Perkel Residence 12/17/2015 System Name Floor Area HVAC .2 425 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible I Latent CFM I Sensible bed 2 Bedroom #2 1 326 9,981 539 326 9,981 539 465 12,399 PAGE TOTAL TOTAL' 326 9,981 539 465 12,399 326 9,981 539 465 12,399 Total includes ventilation load for zonal systems. EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17T09:17:10 ID: Page 33 of 51 ROOM LOAD SUMMARY Project Name • Perkel Residence System Name HVAC 5 ROOM LOAD SUMMARY Date 12/17/2015 Floor Area 1.110 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible I Latent CFM Sensible Latent CFM I Sensible 2 /lrmedia2nd Floor Media Room 1 755 16,083 1,409 755 16,083 1,409 384 15,949 PAGE TOTAL TOTAL" 755 16,083 1,409 384 15,94 755 16,0831 1,4091 384 15,94J Total includes ventilation load for zonal systems. EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17T09:17:10 /D: Pace 35 of 51 C� • f#OOM HEATING PEAK LOADS Project Name Perkel Residence Date 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 1,540.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F Btu/hr R-38 Roof(R.38.2x14.16) 1,540.0 X 0.0260 46 _ 1,842 R-21 Wall (W. 19.2x6.16) 2,688.4 X X 0.0690 46 = 8,533 dual non metal tinted. 32.29 171.6 0.3200 46 c 2,526 Slab -On -Grade perim = 125.0 X X 0.7300 46 = 4,198 "R-0 Interior Wall 584.0 0.3560 0 c 0 X = X = X = X X = = X = X = X X = = X = X = X X = = X = X = X X = X = X X = X = X X X = = = = X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 1,540 X Area Ceiling another room 9.00 X 0.361 Height ACH Page Total /60] X 46 AT 17,098 = 4,086 TOTAL HOURLY HEAT LOSS FOR ROOM 21,184 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17T09:17:10 ID: Page 36 of 51 • I • ROOM HEATING PEAK LOADS Project Name712/17/2015 Perkel Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room Living Kitchen Floor Area 2,634. 0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF c _ _ _ = _ = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof(R.38.2x14.16) 2,634.0 X 0.0260 46 3,150 R-21 Wall (W.19.2x6.16) 4,630.4 X X 0.0690 46 14,697 dual non metal tinted. 32.29 771.6 0.3200 46 11,358 Wood Door 48.0 X 0.5000 46 1,104 Slab -On -Grade perim = 245.0 X X X 0.7300 46 8,227 'R-0 Interior Wall 812.0 0.3560 0 0 X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 2,634 X Area Ceiling another room 9.00 X 0.361 Height ACH Page Total /60] X AT 38,536 TOTAL HOURLY HEAT LOSS FOR ROOM 45,525 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17709:17:10 ID: Page 37 of 51 4 FIOOM HEATING PEAK LOADS Project Name Date Perkel Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom #3 Floor Area 425.0 #z Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F _ _ _ _ c = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 425.0 0.0260 46 508 R-21 Wall (W.19.2x6.16) 2,164.0 0.0690 46 6,869 dual non metal tinted. 32.29 136.0 0.3200 46 2,002 Slab -On -Grade perim = 80.0 0.7300 46 2,686 "R-0 Interior Wall 425.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 425 X Area another room 9.00 X 0.361 Height ACH Page Total /60J X AT 12,065 _ 1,128 TOTAL HOURLY HEAT LOSS FOR ROOM 13,193 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 201 5-1 2-1 7 709:17:10 ID: Page 38 of 51 4 LJ • F#OOM HEATING PEAK LOADS Project Name f Perkel Residence Date 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom #2 Floor Area 425.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OT 'F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 425.0 0.0260 46 508 R-21 Wall (W. 19.2x6.16) 1,914.0 0.0690 46 6,075 dual non metal tinted. 32.29 136.0 0.3200 46 2,002 Slab -On -Grade perim = 80.0 0.7300 46 2,686 'R-0 Interior Wall 425.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 425 X Area another room 9.00 X 0.361 Height ACH Page Total /60] X AT 11,272 = 1,128 TOTAL HOURLY HEAT LOSS FOR ROOM 12,399 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17T09:17:10 /D: Page 39 of 51 • • • ROOM HEATING PEAK LOADS Project Name712/17/2015 Perkel Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Office Floor Area 355.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F = = = _ = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof(R.38.2x14.16) 355.0 0.0260 46 425 R-21 Wall (W.19.2x6.16) 1,612.0 0.0690 46 5,116 dual non metal tinted. 32.29 180.0 0.3200 46 2,650 'R-0 Intedor Wall 355.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 355 X Area another room 9.00 X 0.361 Height ACH Page Total /60] X AT 8,191 TOTAL HOURLY HEAT LOSS FOR ROOM 9,133 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17709:17:10 ID: Page 40 of 51 • C ROOM HEATING PEAK LOADS Project Name Perkel Residence Date 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Media Room Floor Area 1,110.0 ft2 Indoor Dry Bulb Temperature 72 TF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX XI to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = _ _ = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 1,110.0 0.0260 46 1,328 R-21 Wall (W. 19.2x6.16) 2,813.4 0.0690 46 8,930 dual non metal tinted. 32.29 186.6 0.3200 46 2,747 'R-0 Interior Wall 512.0 0.3560 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,110 X Area another room 9.00 X 0.361 Height ACH Page Total /60] X AT 1 13,004 _ 2,945 TOTAL HOURLY HEAT LOSS FOR ROOM 15,949 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17T09:17:10 ID: Page 41 of 51 LJ 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Perkel Residence 1 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,540.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (VV) 1,540.0 X 0.0260 X 56.0 = 2,242 R-21 Wall (W.19.2x6.16) (N) 652.0 X 0.0690 X 23.0 = 1,035 R-21 Wall (W.19.2x6.16) (E) 506.0 X 0.0690 X 33.0 = 1,152 R-21 Wall (W.19.2x6.16) (S) 506.0 X 0.0690 X 26.0 = 908 R-21 Wall (W.19.2x6.16) (lM 1,024.4 X 0.0690 X 33.0 = 2,333 "R-0 Interior Wall 584.0 X 0.3560 X 0.0 = 0 X X = X X = X L X = Page Total 7,669 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 15 (N) 0.0 X 17.2 + 24.0 X 17.2 = 412 13 (N) 0.0 X 17.2 + 80.0 X 17.2 = 1,373 J (tM 0.0 X 17.2 + 40.0 X 34.4 = 1,375 14 (lM 0.0 X 17.2 + 21.6 X 34.4 = 743 H (lM 0.0 X 17.2 + 6.0 X 34.4 = 206 X + X = X + X = X + X = X + I X = Page Total 1 4,109 Internal Gain Btu/hr Occupants 4 6 Occupants X 245 Btuh/occ.= 1,132 Equipment 1,540 Floor Area X 0.50 w/sgft = 2,628 Infiltration: 1.064 X 1.19 X 63.52 X 36 = 2,893 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,432 Latent Gain Btulhr Occupants 4.6 Occupants X 155 Btuh/occ. = 716 Infiltration: 4,771 X 1.19 X 63.52 X 0.00344 = 1,238 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 716 EnerqyPro 6.7 by Ener Soft User Number: 6712 Run Code: 2015-12-17709:17:10 ID: Page 42 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name • Perkel Residence ROOM INFORMATION DESIGN CONDITIONS Date 12/17/2015 Room Name Great Room Living Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 2,634.0 ft2 I Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) Wood Door I R-21 Wall (W.19.2x6.16) Wood Door `R-0 Interior Wall Orientation (tM (N) (E) (S) (S) (►M (iM Area X X X X X X X X X U -Factor X X X X X X X X X CLTDt = = = = = = = = = 2,634.0 0.0260 56.0 1,109.0 0.0690 23.0 1,388.4 0.0690 33.0 1,255.0 0.0690 26.0 24.0 0.5000 26.0 878.0 0.0690 33.0 24.0 0.5000 33.0 812.0 0.3560 0.0 40.0 34.4 0.0 17.2 80.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded FanaStratinn 12 11 G 9 22 21 3 1 T Oripntatinn (N) (N) (E) (E) (E) (E) (S) (S) (S) Btu/hr 1,760 3,161 2,251 312 1,999 396 0 1 13,7151 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 17.2 295.0 17.2 0.0 17.2 96.0 17.2 0.0 17.2 30.0 34.4 0.0 17.2 21.6 34.4 0.0 17.2 20.0 34.4 0.0 17.2 40.0 34.4 0.0 17.2 80.0 17.2 0.0 17.2 120.0 17.2 0.0 F 17.2 6.0 17.2 Page Total Btu/hr 5,063 1,647 1,031 743 688 1,375 1,378 2,068 14, Internal Gain Btu/hr Occupants 7 9 Occupants X 245 Btuh/occ. 1,936 Equipment 2,634 Floor Area X 0.50 w/sqft 4,495 Infiltration: 1.064 X 1.19 X 108.64 X 36 = 4.949 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 41,099 Latent Gain Btulhr Occupants 7.9 Occupants X 155 Btuh/occ. = 1,225 Infiltration: 4.771 X 1.19 X 108.64 X 0.00344 = 2,118 Air Sensible CFM ELA AW Oil TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 FnerovPrn 6.7 by EnerovSoft User Number: 6712 RunCode: 2015-12-17709:17:10 ID: Page 43 of 51 • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Perkel Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room Living Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 2,634.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr N (S) 0.0 X 17.2 + 15.0 X 17.2 = 258 2 (tM 0.0 X 17.2 + 24.0 X 34.4 = 825 M (tM 0.0 X 17.2 + 8.0 X 34.4 = 275 L (tq 0.0 X 17.2 + 8.0 X 34.4 = 275 K' (lM 0.0 X 17.2 + 8.0 X 34.4 = 275 X + X = X + X = X + X = X + X = Page Total 1,909 Internal Gain Btu/hr Occupants 7 9 Occupants X 245 Btuh/occ. = 1,936 Equipment 2,634 Floor Area X 0.50 w/sgft = 4,495 Infiltration: 1.064 X 1.19 X 108.64 X 36 = 4,949 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 41,099 Latent Gain Btu/hr Occupants 7 9 Occupants X 155 Btuh/occ. = 1,225 Infiltration: 4,771 X 1.19 X 108.64 X 0.00344 = 2,118 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,225 Ener Pro 6.7 by EnerqySoft User Number: 6712 RunCode: 2015-12-17T09:17:10 /D: Page 44 of 51 C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Perkel Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom #3 Outdoor Dry Bulb Temperature 112 OF Floor Area 425.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-38 Roof(R. 38.2x 14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W 19.2x6.16) R-21 Wall (W 19.2x6.16) 'R-0 Interior Wall Orientation (W) (N) (E) (VV) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD1 = = = = = = = = = 425.0 0.0260 56.0 457.0 0.0690 23.0 620.0 0.0690 33.0 477.0 0.0690 26.0 610.0 0.0690 33.0 425.0 0.3560 0.0 1.0 0.0 17.2 1.0 0.0 17.2 1.0 0.0 17.2 1.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FF EE DD 4 CC BB AA Z Y OriPntatinn (N) (N) (N) (N) (E) (E) (E) (E) (E) Btu/hr 1, 1, 1 5,0011 Shaded Area X X X X X X X X X1 GLF + + + + + + + + +1 Unshaded Area GLF X 17.2 X 17.2 X 17.2 X 17.2 X 34.4 X 34.4 X 34.4 X 34.4 X1 34.4 Page Total = = = = = = = = = 0.0 17.2 1.0 0.0 17.2 1.0 0.0 17.2 1.0 0.0 17.2 40.0 0.0 17.2 1.0 0.0 17.2 1.0 0.0 17.2 1.0 0.0 17.2 1.0 0.0 17.2 1.0 Btu/hr 17 17 17 686 34 34 34 34 91 Internal Gain Btu/hr Occupants 1.3 Occupants X 245 Btuh/occ. 31 Equipment 425 Floor Area X 0.50 w/sgft = 7 Infiltration: 1.064 X 1.19 X 17.53 X 36 =79 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10.3771 Latent Gain Btu/hr Occupants 13 Occupants X 155 Btuh/occ. = 198 Infiltration: 4,771 X 1.19 X 17.53 X 0.00344 = 342 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 198 EnerovPro 6.7 by EnerovSoft User Number: 6712 RunCode: 2015-12-17709:17:10 ID: Paoe 45 of 51 1 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name712/17/2015 ate Perkel Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom #3 Outdoor Dry Bulb Temperature 112 OF Floor Area 425.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr D (E) 0.0 X 17.2 + 12.5 X 34.4 = 430 c (E) 0.0 X 17.2 + 12.5 X 34.4 = 430 V (S) 0.0 X 17.2 + 1.0 X 17.2 = 17 W (S) 0.0 X 17.2 + 1.0 X 17.2 = 17 X (S) 0.0 X 17.2 + 1.0 X 17.2 = 17 B (S) 0.0 X 17.2 + 10.0 X 17.2 = 172 A (S) 0.0 X 17.2 + 10.0 X 17.2 = 172 5 (tM 0.0 X 17.2 + 40.0 X 34.4 = 1,375 X + X = Page Total 2,631 Internal Gain Btu/hr Occupants 1.3 Occupants X 245 Btuh/occ. = 312 Equipment 425 Floor Area X 0.50 w/sgft = 725 Infiltration: 1.064 X 1.19 X 17.53 X 36 = 798 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,377 Latent Gain Btulhr Occupants 13 Occupants X 155 Btuh/occ. = 198 Infiltration: 4,771 X 1.19 X 17.53 X 0.00344 = 342 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 198 Ener Pro 6.7 by Ene Soft User Number: 6712 RunCode: 2015-12-17709:17:10 /D: Page 46 of 51 1� RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Perkel Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom #2 Outdoor Dry Bulb Temperature 112 OF Floor Area 425.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) -R-0 Intedor Wall Orientation (lM (N) (E) (S) (tM Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 425.0 0.0260 56.0 207.0 0.0690 23.0 610.0 0.0690 33.0 477.0 0.0690 26.0 620.0 0.0690 33.0 425.0 0.3560 0.0 17.2 0.0 1.0 17.2 0.0 1.0 17.2 I 10.0 17.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration KK JJ HH 20 19 TT SS RR R Orientation (N) (N) (N) (N) (E) (S) (S) (S) (S) Shaded Area GLF X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X1 17.2 + + + + + + + + +1 Unshaded Area X X X X X X X X X1 GLF = = = = = = = = = 0.0 1.0 17.2 0.0 1.0 17.2 0.0 1.0 17.2 0.0 40.0 17.2 0.0 40.0 34.4 0.0 1.0 17.2 0.0 1.0 17.2 0.0 1.0 17.2 0.0 10.0 17.2 Page Total Btulhr 619 329 1,389 856 1,412 0 4, 604 Btulhr 17 17 17 686 1,375 17 17 17 172 Internal Gain Btu/hr Occupants 1.3 Occupants X 245 Btuh/occ. 312 Equipment 425 Floor Area X 0.50 w/sgft = 725 Infiltration: 1.064 X 1.19 X 17.53 X 36 = 798 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,981 Latent Gain Btu/hr Occupants 13 Occupants X 155 Btuh/occ. = 198 Infiltration: 4,771 X 1.19 X 17.53 X 0.00344 = 342 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 198 EnerovPro 6.7 by EnerovSoft User Number: 6712 RunCode: 2015-12-17709:17:10 ID: Paqe 47 of 51 Ll C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name712/17/2015 ate Perkel Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 42 Outdoor Dry Bulb Temperature 112 OF Floor Area 425.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr S (S) 0.0 X 17.2 + 10.0 X 17.2 = 172 QQ (Vl/) 0.0 X 17.2 + 1.0 X 34.4 = 34 PP AM 0.0 X 17.2 + 1.0 X 34.4 = 34 NN (VV) 0.0 X 17.2 + 1.0 X 34.4 = 34 MM (VV) 0.0 X 17.2 + 1.0 X 34.4 = 34 LL (VV) 0.0 X 17.2 + 1.0 X 34.4 = 34 Q (VV) 0.0 X 17.2 + 12.5 X 34.4 = 430 P (Vlo 0.0 X 17.2 + 12.5 X 34.4 = 430 X +1 X = Page Total 1,204 Internal Gain Btu/hr Occupants 1.3 Occupants X 245 Btuh/occ. = 312 Equipment 425 Floor Area X 0.50 w/sgft = 725 Infiltration: 1.064 X 1.19 X 17.53 X 36 = 798 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,981 Latent Gain Btu/hr Occupants 13 Occupants X 155 Btuh/occ. = 198 Infiltration: 4,771 X 1.19 X 17.53 X 0.00344 = 342 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 198 EneMyPro 6.7 by Ener Soft User Number: 6712 RunCode: 2015-12-17709:17:10 /D: Page 48 of 51 Ah f L I • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name712/17/2015 ate Perkel Residence ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Office Outdoor Dry Bulb Temperature 112 OF Floor Area 355.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (VV) 355.0 X 0.0260 X 56.0 = 517 R-21 Wall (W.19.2x6.16) (N) 338.0 X 0.0690 X 23.0 = 536 R-21 Wall (W.19.2x6.16) (E) 438.0 X 0.0690 X 33.0 = 997 R-21 Wall (W.19.2x6.16) (S) 438.0 X 0.0690 X 26.0 = 786 R-21 Wall (W.19.2x6.16) 398.0 X 0.0690 X 33.0 = 906 "R-0 Interior Wall 355.0 X 0.3560 X 0.0 = 0 X X = X X = X X = Page Total 3,743 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr AF (N) 0.0 X 17.2 + 30.0 X 17.2 = 515 44 (N) 0.0 X 17.2 + 80.0 X 17.2 = 1,373 AE (E) 0.0 X 17.2 + 10.0 X 34.4 = 344 AD (S) 0.0 X 17.2 + 10.0 X 17.2 = 172 AJ (VIO 0.0 X 17.2 + 10.0 X 34.4 c 344 AH (Vto 0.0 X 17.2 + 30.0 X 34.4 = 1,031 AG (lM 0.0 X 17.2 + 10.0 X 34.4 = 344 X + X = X + X = Page Total 4,123 Internal Gain Btu/hr Occupants 1 1 Occupants X 245 Btuh/occ. = 261 Equipment 355 Floor Area X 0.50 w/sgft = 606 Infiltration: 1.064 X 1.19 X 14.64 X 36 = 667 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,399 Latent Gain Btu/hr Occupants 1 1 Occupants X 155 Btuh/occ. = 165 Infiltration: 4,771 X 1.19 X 14.64 X 0.00344 = 285 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 165 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17T09:17:10 /D: Page 49 of 51 7 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Perkel Residence ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Media Room Outdoor Dry Bulb Temperature Floor Area 1,110.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: C Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) 'R-0 Interior Wall Orientation (tM (N) (E) (S) (►M Date 12/17%2015 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD1 = = = = = = = = = 1,110.0 0.0260 56.0 558.0 0.0690 23.0 819.4 0.0690 33.0 598.0 0.0690 26.0 838.0 0.0690 33.0 512.0 0.3560 0.0 0.0 17.2 6.3 34.4 0.0 17.2 12.0 34.4 0.0 17.2 6.0 Page Total Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 43 AB ZZ yy xx WW VV UU 42 Orientation (N) (N) (E) (E) (E) (E) (S) (S) (S) Shaded Unshaded 112 OF 78 OF 34 OF Btu/hr 1,616 886 1,866 1,073 1,908 0 1 7,3481 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = - 0.0 17.2 80.0 17.2 0.0 17.2 12.0 17.2 0.0 17.2 6.0 34.4 0.0 17.2 6.3 34.4 0.0 17.2 6.3 34.4 0.0 17.2 12.0 34.4 0.0 17.2 6.0 17.2 0.0 17.2 6.0 17.2 0.0 17.2 40.0 17.2 Page Total Btulhr 1,373 206 206 217 217 413 103 103 689 Internal Gain Btu/hr Occupants 3 3 Occupants X 245 Btuh/occ. 816 Equipment 1,110 Floor Area X 0.50 w/sgft = 1,894 Infiltration: 1.064 X 1.19 X 45.78 X 36 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,0831 Latent Gain Btu/hr Occupants 3 3 Occupants X 155 Btuh/occ. = 516 Infiltration: 4,771 X 1.19 X 45.78 X 0.00344 = 893 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 51 7 w r-1 L–J ESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Perkel Residence 12/17/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Media Room Outdoor Dry Bulb Temperature 112 OF Floor Area 1,110.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr AC (lM 0.0 X 17.2 + 12.0 X 34.4 = 413 X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 413 Internal Gain Btu/hr Occupants 3 3 Occupants X 245 Btuh/occ. = 816 Equipment 1,110 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.19 X 45.78 X 36 = 2,085 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,083 Latent Gain Btu/hr Occupants 3 3 Occupants X 155 Btuh/occ. = 516 Infiltration: 4,771 X 1.19 X 45.78 X 0.00344 = 893 Air Sensible CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 516 Ener Pro 6.7 by EnerqySoft User Number: 6712 Run Code: 2015-12-17709:17:10 ID: Page 51 of 51