0307-180 (CSCS) Title 24t } I 1 TITLE 24 REPORT I Title 24 Report for: La Quinta Grill Offices 78-034 Calle Barcelona . La Quinta, CA Project Designer: 0 Report Prepared By: Joan D. Hacker Insu-form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 LNep 'ry u rr CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED Job Number: r!^r% ^^kt[-V-n. .,.-r,,... EXTE 3 W =UM'1M 449-1 Date:. 78'02l�.78•0 �a! 5/22/2003 D� D 307 -18 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. User Number. 2655 TABLE OF CONTENTS Cover Page Table of Contents Form ENV -1 Certificate of Compliance Form ENV -2 Overall Envelope Method Form ENV -MM Envelope Mandatory Measures Form LTG -1 Certificate of Compliance Form LTG -2 Lighting Compliance Summary Form LTG -4 Tailored LPD Summary and.Worksheet Form LTG -5 Room Cavity Ratio Worksheet Form LTG -MM Lighting Mandatory Measures Form MECH-1 Certificate of Compliance Form MECH-2 Mechanical Equipment Summary Form MECH-3 Mechanical Ventilation Form MECH-4 Mechanical Sizing and Fan Power Form MECH-MM Mechanical Mandatory Measures Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 5 11 12 15 16 17 18 19 21 23 24 26 28 30 EnergyPro 3.1 By EnergySoft Job Number. User Number. 2655 1 CERTIFICATE OF COMPLIANCE Part 1 of 2 ENV -1 (PROJECT NAME DATE La Quinta Grill Offices 5/22/2003 PROJECT ADDRESS 78-034 Calle Barcelona La Quinta !PRINCIPAL DESIGNER - ENVELOPE j TELEPHONE Building Permit # � I DOCUMENTATION AUTHOR { TELEPHONE Checked by/Date Insu-form, Inc. , 760) 324-2046 Enforcement A en Use GENERAL INFORMATION ;DATE OF PLANS (BUILDING CONDITIONED FLOOR AREA (CLIMATE ZONE 5,954 Sq.Ft. 15 BUILDING TYPE NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION C NEW CONSTRUCTION 0 ADDITION [] ALTERATION EXISTING -ADDITION METHOD OF ENVELOPE 71 COMPONENT ® OVERALL ENVELOPE PERFORMANCE j COMPLIANCE STATEMENT OF COMPLIANCE ;This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, t Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building envelope requirements. ` t j jThe documentation preparer hereby certifies that the document is accurate and complete. i DOCUMENTATION AUTHOR SIGNA URE DATE Joan D. Hacker The Principal Envelope Designer hereby certifies that the pro gose building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other submitted with this permit application. The proposed building has been designed to meet the envelope ; (calculations requirements contained in Sections 110, 116 through 118, and 140, 142, 143 or 149 of Title 24, Part 6. I Please check one: i � I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this ; document as the person responsible for its preparation; and that I am licensed in the state of California as a civil engineer or i i mechanical engineer, or I am a licensed architect. !{ In I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or j 6737.3 to sign this document as the person responsible for its preparation; and that I am a I licensed contractor performing this work. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. PRINCIPAL ENVELOPE DESIER-AME SIGNATU EJDATE�.j LIC. #�'D ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. ENV -1: Required on plans for all submittals. Part 2 may be incorporated in schedules on plans. ENV -2: Used for all submittals; choose appropriate version depending on method of envelope compliance. ENV -3: Optional. Use if default U -values are not used. Choose appropriate version for assembly U -value to be calculated. EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:3 of 31 ENVELOPE COMPLIANCE SUMMARY Part 2 of 2 ENV -1 PROJECT NAME La Quintal Grill Offices Area U -Fac. Act. Azm. SHGC Glazing Type DATE 5/22/2003 OPAQUE SURFACES 100 0.710 0 0.63 Mtl Thermal Brk Unctd Default ffices 2 Window Surface Framing # Type Type Act. Area U -Fac. Azm. Tilt Solar Gains Y/N Form 3 Reference Location / Comments 1 Wall Wood 400 0.049 0 90 1 X I Premier Structural Building Panels Offices 2 Door None 40 0.387 0 90 1 X I Solid Wood Door Offices 3 Wall Wood 353 0.049 90 90 X I Premier Structural Building Panels Offices 4 Wall Wood 324 0.049 180 90 2 1 Premier Structural Building Panels Offices 5 Wall Wood 328 0.049 270 90 X I Premier Structural Building Panels Offices 6 Roof Wood 2,977 0.028 180 0 X I R-38 Roof R.38.2x14.16 Offices 7 Wall Wood 400 0.049 90 90 & I I Premier Structural BuildingPanels Offices 8 Door None 40 0.387 90 90 1 X I I Solid Wood Door Offices 9 Wall Wood 378 0.049 180 90x I I Premier Structural Building Panels Offices 10 Wall Wood 324 0.049 270 90 X I I Premier Structural Building Panels Offices 11 Wall Wood 328 1 0.049 0 90 X I I Premier Structural Building Panels Offices 12 Roof Wood 2,977 1 0.028 180 0 X I I R-38 Roof R.38.2x14.16) Offices Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. Hat. Right Fin Dist. Len. H t 1 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 2 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 3 None 0.76 4.0 4.0 2.0 0.1 2.0 2.0 4 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 5 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 6 None 0.76 4.0 4.0 2.0 0.1 2.0 2.0 7 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 FENESTRATION SURFACES Site Assembled Glazing CheCK box it Building is >= 100,000 sqtt of GFA and >= 10,000 sqtt vertical glazing then NFRC Certification is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form. # Type Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments 1 Window 100 0.710 0 0.63 Mtl Thermal Brk Unctd Default ffices 2 Window 25 0.710 90 0.63 Mtl Thermal Brk Unctd Default ffices 3 Window 16 0.710 180 0.63 Mtl Thermal Brk Unctd Default ffices 4 Window 50 0.710 270 0.63 Mtl Thermal Brk Unctd Default Dffices 5 lWindow 100 0.710 90 0.63 Mtl Thermal Brk Unctd Default ffices 6 Window 16 0.710 270 0.63 Mtl Thermal Brk Unctd Default Dffices 7 Window 50 0.710 0 0.63 Mtl Thermal Brk Unctd Default Dffices EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. Hat. Right Fin Dist. Len. H t 1 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 2 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 3 None 0.76 4.0 4.0 2.0 0.1 2.0 2.0 4 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 5 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 6 None 0.76 4.0 4.0 2.0 0.1 2.0 2.0 7 None 0.76 5.0 5.0 2.0 0.1 2.0 2.0 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:4 of 31 OVERALL ENVELOPE METHOD Part 1 of 6 ENV -2 PROJECT NAME DATE La Quinta Grill Offices 5/22/2003 WINDOW AREA TEST A. DISPLAY PERIMETER B. GROSS EXTERIOR WALL AREA C. GROSS EXTERIOR WALL AREA D. ENTER LARGER OF A or B E. ENTER PROPOSED WINDOW AREA 0 ftX6= 3 272 sf X 0.40 = 3 272 sf X 0.10 = —� sf DISPLAY AREA sf 40% AREA 32 sf MINIMUM STND. AREA 1,300 sf MAXIMUM STND. AREA 35 sf PROPOSED AREA F. WINDOW WALL RATIO = Proposed Window Area Divided by Gross Exterior Wall Area = 1 10.91% IF E IS GREATER THAN D OR LESS THAN C, PROCEED TO THE NEXT CALCULATION FOR THE WINDOW AREA ADJUSTMENT. IF NOT, GO TO PART 2 OF 6. 1. IF E GREATER THAN D: MAXIMUM PROPOSED WINDOW STANDARD AREA WINDOW AREA ADJUSTMENT FACTOR S GO TO PART 6 TO CALCULATE ADJUSTED AREAS. 2. IF LESS THAN C: MINIMUM PROPOSED WINDOW STANDARD AREA AREA ADJUSTMENT FACTOR GO TO PART 6 TO CALCULATE ADJUSTED AREAS. I SKYLIGHT AREA TEST ATRIUM HEIGHT 101 FT IF -55 FT IF>55FT 41 0.101 X I= 0.05 X 5.9 = 298 STANDARD % GROSS STANDARD ROOF AREA SKYLIGHT AREA PROPOSED SKYLIGHT AREA IF THE PROPOSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED TO THE NEXT CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT. IF NOT, GO TO PART 2 OF 6. 1. IF PROPOSED SKYLIGHT AREA >= STANDARD SKYLIGHT AREA: SKYLIGHT STANDARD SKYLIGHT AREA PROPOSED SKYLIGHT AREA ADJUSTMENT FACTOR GO TO PART 6 TO CALCULATE ADJUSTED AREAS. EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:5 of 31 OVERALL ENVELOPE METHOD Part 2 of 6 ENV -2 �V-ERA OJECT NAME DATE La uinta Grill Offices 5/22/2003 LL HEAT LOSS ASSEMBLY NAME (e.g. Wall -1, Floor -1) Front Wall Window Left Wall Window Rear Wall Window Right Wall Window Roof Front Wall Window Left Wall Rear Wall Window Right Wall Window Roof PROPOSED AREA" (Adjusted) AREA HEAT CAPACITY U- FACTOR TABLE VALUES UA (B X D) Y N 400 3.86 0.049 [91 ❑ 19.5 100 324 0.710 ❑ X 71.0 353 3.86 0.049 X ❑ 17.2 25 2,977 0.710 ❑ 0 17.8 324 3.86 0.049 0 ❑ 15.8 16 3241 0.710 ❑ 0 11.4 328 3.86 0.049 X ❑ 16.0 50 2,977 0.710 ❑ ® 35.5 2,977 3.00 0.028 N. ❑ 84.4 400 3.86 0.049 ® ❑ 19.5 100 0.710 El 2171.0 378 3.86 0.049 X ❑ 18.4 324 3.86 0.049 ❑ 15.8 16 0.710 ❑ a 11.4 328 3.86 0.049 ❑ 16.0 50 0.710 ❑ X 35.5 2,977 3.00 0.028 ❑ 84.4 ❑ ❑ El El F-1 El El El El El 1:1 El STANDARD AREA" (Adjusted) U -FACTOR UA (F X G) 400 0.084 33.6 1001 0.490 49.0 353 0.084 29.7 25 0.49C 12.2 324 0.084 27.2 16 0.49C 7.8 328 0.084 27.6 50 0.490 24.5 2,977 0.057 169.7 400 0.084 33.6 100 0.490 49.0 378 0.084 31.8 3241 0.084 27.2 16 0.49q 7.8 328 0.084 27.6 50 0.49C 24.5 2,977 0.057 169.7 • If Window and/or Skylight Area Adjustment is Required, Column E shall be 560 This Page Total 752 use Adjusted Areas from Part 6 of 6. no greater than Column H 560 Building Total 752 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:6 of 31 1 OVERALL ENVELOPE METHOD Part 3 of 6 ENV -2 PROJECT NAME La Quinta Grill Offices DATE 5/22/2003 VERALL HEAT GAIN FROM CONDUCTION FA aoa a a a o a o PROPOSED STANDARD TABLE HEAT HEAT ASSEMBLY NAME HEAT U- VALUES GAIN AREA' U- GAIN (e.g. Wall -1, Floor -1) AREA TF CAPACITY FACTOR y N BxCxE) (Adjusted) FACTOR TF GxHxl Front Wall 400 55 3.86 0.049 X❑ ❑ 1,072 400 0.084 55 1,848 Window 1001 551 0.710 ❑ a 3,905 100 0.4901 55 2,695 Left Wall 353 55 3.86 0.049 ©❑ 946 353 0.084 55 1,631 Window 25 55 0.710 ❑ a 976 25 0.490 55 674 Rear Wall 324 55 3.86 0.049 a ❑ 868 324 0.084 55 1,497 Window 16 55 0.710 ❑ ❑X 625 16 0.490 55 431 Right Wall 328 55 3.86 0.049 X❑ ❑ 879 328 0.084 55 1,515 Window 50 55 0.710 ❑ ® 1,952 50 0.490 55 1,348 Roof 2,977 55 3.00 0.028 ®❑ 4,642 2,977 0.057 55 9,333 vont Wall 400 55 3.86 0.049 ®❑ 1,072 400 0.084 55 1,848 Window 100 55 0.710 ❑ 3,905 100 0.490 55 2,695 eft Wall 378 55 3.86 0.049 ❑ 1,013 378 0.084 55 1,746 Rear Wall 324 55 3.86 0.049 ❑ 868 324 0.084 55 1,497 Window 16 55 0.710 ❑ ❑X 625 16 0.4901 55 431 Right Wall 328 55 3.86 0.049 ❑ 879 328 0.084 55 1,515 Window 50 55 0.710 ❑ ❑X 1,952 50 0.490 55 1,348 Roof 2,977 55 3.00 0.028 ❑ 4,642 2,977 0.057 55 9,333 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El F-1 F-1 El ❑❑ El El 30,821 41,385 Subtotal Subtotal • If Window and/or Skylight Area Adjustment is Required, use Adjusted Areas from Part 6 of 6. EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page:7 of 31 OVERALL ENVELOPE METHOD Part 4 of 6 ENV -2I PROJECT NAME DATE La Quinta Grill Offices I 5/22/2003 H a a E 8,596 SUBTOTAL 26,883 SUBTOTAL EnergyPro 3.1 By EnergyPro User Number: 2655 Job Number. Page:8 of 31 PROPOSED STANDARD ASSEMBLY NAME e.g. Roof -1) AREA SF WEIGHTING FACTOR U- FACTOR Absorp HEAT GAIN (BxCxDxExF) AREA* (ADJUSTED) U -Factor Absorp HEAT GAIN (CxDxHxlxJ) Roof 2.977 123 0.92. 0.028 0.45 4,298 2,977 0.057 0.70 13,441 Roof 2,977 123 0.92 0.028 0.45 4,298 2,977 g.057 0.70 13 441 8,596 SUBTOTAL 26,883 SUBTOTAL EnergyPro 3.1 By EnergyPro User Number: 2655 Job Number. Page:8 of 31 OVERALL ENVELOPE METHOD Part 5 of 6 ENV -2 PROJECT NAME DATE La Quinta Grill Offices 1 5/22/2003 IOVERALL HEAT GAIN FROM RADIATION FENESTRATION SURFACES I 0 o aaaaaao 0 0©0 PROPOSED STANDARD INDOWISKYLIGHT NAME e.g. Wind -1, Sky -1) ORIENT. WEIGHTING FACTOR AREA SF SHGC OVERHANG HEATOGAIN (BxCxDxExH) AREA* (ADJUSTED) RSHG (or SHGC") SF HEATOGAIN (BxJxKxL) H V HIV OHF Window N 0.61 10C 123. 0.63 2.0 5.1 0.39 0.87 4,112 100 0.51 123 3,827 Window E 1.07 2E 123 0.63 2 0 5.1 0.39 0.69 1,437 25 0.36 1231 1 184 Window S 1.27 A 123 0.63 2.0 4.1 0.49 0.56 885 16 0.36 123 900 Window W 1.05 5 123 2.819 50 0.36 123 2,325 Window E 1.07 10 123 0.63 2.0 5.1 0.39 0.69 5,746 100 0.36 123 4.738 Window W 1.05 1 123 0.63 2.0 4 0,490.63 826 16 0.36 123 744 Window N 0.61 5 123 0.63 2.0 5.1 0.39 0.87 2,056 50 0.51 123 1.913 " Only SHGC is Part 3 Subtotal 30,821 Part 3 Subtotal 41,385 used for Skylights Part 4 Subtotal 8,596 Part 4 Subtotal 26,883 'If Window and/or Skylight Area Column I must be Adjustment is Required, use less than column M Part 5 Subtotal 17,882 Part 5 Subtotal15,63 Adjusted Areas from Part 6 of 6. 57,299 Total Heat Gain 83,898 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:9 of 31 OVERALL ENVELOPE METHOD Part 6 of 6 ENV -2 PROJECT NAME DATE La Quinta Grill Offices 1 5/22/2003 CHECK IF NOT APPLICABLE (See Part 1 of 6.) ISKYLIGHT AREA ADJUSTMENT CALCULATIONS RX CHECK IF NOT APPLICABLE (See Part 1 of 5.) ROOF NAME (e.g. Roof -1, Roof -2) I a GROSS AREA © SKYLIGHT AREA D❑ a SKYLIGHT ADJUST. FACTOR (From Part 1) ADJUSTED SKYLIGHT AREA (C X D) ADJUSTED ROOF AREA (B - E) j ,I I TOTALS N/A EnergyPro 31 By EnergySoft User Number 2655 Job Number: Page: 10 of 31 ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME DATE La QuintalGrill Offices 5/22/2003 DESCRIPTION IDesimer lEnforcement J§118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. i, § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and i fire doors), U § 116(a)1 Manufactured Doors and Windows Installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured i fenestration products must be labeled for U -value according to NFRC procedures. X] §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls In nonresidential buildings shall have Insulation with an installed R -value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:11 of 31 CERTIFICATE OF COMPLIANCE Part 1 of 3 LTG -1 PROJECT NAME DATE La Quinta Grill Offices 5/22/2003 PROJECT ADDRESS 78-034 Calle Barcelona La Quinta PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit # DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Insu-form, Inc. (760) 324-2046 Enforcement A en Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 5,954 Sq.Ft. 1 15 BUILDING TYPE © NONRESIDENTIAL HIGH RISE RESIDENTIAL [—] HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION [:] ALTERATION Ej EXISTING + ADDITION METHOD OF LIGHTING ® COMPLETE BUILDING AREA CATEGORY 0 TAILORED PERFORMANCE COMPLIANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNAT RE DATE Joan D. Hacker The Principal Lighting Designer hereby certifies that the propo d wilding design represented in this set of construction documents is consistent with the other compliance forms and wor sheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 through 132, and 146 or 149 of Title 24, Part 6. Please check one: I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE ]DATE LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. LTG -1: Required on plans for all submittals. Part 2 and 3 may be incorporated in schedules on plans. LTG -2: Required on all submittals. LTG -3: Optional. Use only if lighting control credits are taken. LTG -4: Optional. Use only if Tailored method is used. LTG -5: Optional. Use only if Tailored method is used. EnergyPro 3.1 By Energysoft User Number 2655 Job Number. Page: 12 of 31 LIGHTING COMPLIANCE SUMMARY Part 2 of 3 LTG - PROJECT NAME DATE La Quinta Grill Offices I 5/22/2003 INSTALLED LIGHTING SCHEDULE LAMPS I BALLASTS 11 Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # WPaetts Lamp DESCRIPTION # Lam + Ballast Total Watts # Watts 4 4 ft Fluorescent T8 Elec F32T8 4 32 Electronic 2. 40 124.0 4,960I MR Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page 4,960 Meets Total 4,960 1,191 F] Efficacy and Control Requirement of§130(c) Portable Lighting (From LTG -1) Less Control Credit Watts (From LTG -3) ❑ Control Requirements of 5131(f) Adjusted Actual Wafts 6,151 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 13 of 31 CONTROL LOCATION I CONTROL I I CONTROL TYPE (Room # or Dwg. #) I IDENTIFICATION (Occupant, Daylight, Dimm NOTE TO FIELD NOTES TO FIELD - For Building Department Use Only EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 13 of 31 LIGHTING COMPLIANCE SUMMARY Part 3 of 3 LTG -1 PROJECT NAME DATE La Quinta Grill Offices I 5/22/2003 ROOM # DEFAULT OR ZONE ID /s ft AREA SF TOTAL WATTS B X C Offices 0.2 2,977 595 Offices 0.2 2,977 595 TOTAL 5,954 1,191 TABLE 1 B - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET a a o a a a a LUMIN. TASK # OF TOTAL TOTAL BUILDING SUMMARY - PORTABLE LIGHTING Designer needs to provide detailed documentation that the Iigt level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. BUILDING SUMMARY TOTAL AREA (SF (FROM TABLES 1A+1*a+1C) TOTAL WATTS (FROM TABLES 1A+1B) BUILDING TOTAL 5,954 1,191 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 14 of 31 LIGHTING COMPLIANCE SUMMARY LTG -2 ECT NAME La Quinta Grill Offices DATE 5/22/2003 LUMINAIRE Y NAME I DESCRIPTION NUMBER OF LUMINAIRES(including WATTS PER LUMINAIRE BallastL_ CEC DEFAULT! Y N ; Total Watts I j J '� 4,9601! i ! '(4) 4 It Fluorescent T8 Elec 40 124.0 C' ❑�I C—' C� ❑7 II ! I! � ! i Subtotal from this Page 4,9601 Building Total I 4,960 11 Portable Lighting (From LTG -1) 1,19 Less Control Credit Watts (From LTG -3) 011 Adjusted Actual Watts 6 15 1ALLOWED LIGHTINGP(Choose COMPLETE BUILDING METHOD WATTS PER SF COMPLETE I BLDG. AREA I ALLOWED WATTS BUILDING CATEGORY (From Table 1-M) Comp Bldg Office ( 1.20 51954 7,145 AREA CATEGORY METHOD WATTS PER SF AREA (SF) ALLOWED WATTS ! AREA CATEGORY (From Table 1-N) j I I ` PAGE TOTAL Q Q BUILDING TOTAL AREA WATTS TAILORED METHOD i TOTAL ALLOWED WATTS (From LTG -4 or from computer run.) I EnergyPro 3.1 By EnergySoft User Number 2655 Job Number. Page: 15 of 31 ! TAILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 (PROJECT NAME DATE La Quinta Grill Offices 5/22/2003 TAILORED LPD SUMMARY 1. Watts for Illuminance Categories A -D (from column G) 0 watts 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) C 0 watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) 01 + 0 + 0 = 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display . 4. Total Allowed Watts (lines 1+2+3) 0 watts TAILORED LPD:- Illuminance Categories A B C and D and Gross Sales Area o © © a o o a ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) Offices A 0.43 0 0.20 0 Offices A 0.43 0 0.20 0 BUILDING PAGE TOTAL TOTAL 01 1 01 5,954 Q SF WATTS EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page: 16 of 31 1 ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG-5 PROJECT NAME DATE La Quinta Grill Offices 1 5/22/2003 a © a o a Room Task/Activity Room Room Room Name Description Length (L) Width (W) Cavity Height (H) 0 LIGHTING MANDATORY MEASURES LTG -MM ECT NAME La Quinta Grill Offices DATE 5/22/2003 DESCRIPTION 1101lesigner IlEnforcement f § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic I control to shut off the lighting. This automatic control shall meet the requirements of ! Section 119 and may be an occupancy sensor, automatic time switch, or other device I capable of automatically shutting off the lighting. § 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. ' CX ! � § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the l manufacturer. I ! U § 111 Flubrescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. I L§ 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp ! fluorescent fixtures are tandem wired with two lamp ballasts where required by i Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. N71 § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. Q§ 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel Inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 18 of 31 CERTIFICATE OF COMPLIANCE Part 1 of 2 MECH-1 PROJECT NAME DATE La Quinta Grill Offices 5/22/2003 j PROJECT ADDRESS ! 78-034 Calle Barcelona La Quintal PRINCIPAL DESIGNER -MECHANICAL TELEPHONE Building Permit # i i iDOCUMENTATION AUTHOR TELEPHONE Checked by/Date ! Insu-form, Inc. (760) 324-2046 Enforcement Agency Use GENERAL INFORMATION !DATE OF PLANS BUILDING CONDITIONED FLOOR AREA ICLIMATE ZONE I 5,954Sg.Ft. ; 15 , i BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑I HOTEL/MOTEL GUEST ROOM !PHASE OF CONSTRUCTION X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION i- EXISTING +ADDITION j !METHOD OF MECHANICAL [XI PRESCRIPTIVE ❑ PERFORMANCE jCOMPLIANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT [y ENVELOPE COMPLIANCE ATTACHED j STATEMENT OF -COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. ThP rinmimantntinn nranarar hPrahv rartifiac that tha rinmimantntinn is arruratP nnrt rmmnlata DOCUMENTATION AUTHOR SIGNATU E DATE Joan D. Hacker 5 The Principal Mechanical Designer hereby certifies that the prop a building design represented'in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in Sections 110 through115, 120 through 124, 140 through 142, 144 and 145. I! Please check one: I ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, or ; mechanical engineer or I am a licensed architect. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a j licensed contractor performing this work. ' ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document j because it pertains to a structure or type of work described pursuant to Business and Professions Code sections 5537, 5538, j and 6737.1. ! PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE DATE f LIC. # MECHANICAL MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures I INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. MECH-1: Required on plans for all submittals. Parts 2 may be incorporated in schedules on plans. jMECH-2: Required for all submittals, but maybe incorporated in schedules on plans. I i MECH-3: Required for all submittals unless required outdoor ventilation rates and airflows are shown on plans per Section 4.3.4. MECH-4: Required for Prescriptive submittals. I MECH-5: Optional. Performance use only for mechanical distribution summary. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:19 of 31 I CERTIFICATE OF COMPLIANCE Part 2 of 2 MECH-1 PROJECT NAME DATE La Quinta Grill Offices 5/22/2003 SYSTEM FEATURES 71 SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE MECHANICAL SYSTEMS DHW Heater Building One I Building Two n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Gas Fired 78% Standard Gas 50 gal or Less n/a n/a Yes Yes n/a n/a n/a n/a n/a Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 496 cfm Gas Furnace 80% AFUE Packaged DX 10.1 EER CARRIER 48HJ0009501 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Require n/a n/a n/a Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 496 cfm Gas Furnace 80% AFUE Packaged DX 10.1 EER CARRIER 48HJD009501 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? SETBACK CTRL. ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? H: Heating SIMULTANEOUS HEAT/ COOL? Y: Yes HEAT AND COOL SUPPLY RESET? N: No HIGH EFFICIENCY? PIPE INSULATION REQUIRED? Sensor PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE M: Manual Timer TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer 0: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air Cert. G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. EnergyPro 3.1 By EnergySort User Number: 2655 Job Number: Page: 20 of 31 IMECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-21 PROJECT NAME DATE I La Quinta Grill Offices 5/22/2003 1 CHILLER AND TOWER SUMMARY HEATING FEfficlericy Tons PUMPS j Equipment Name Equipment Type Qty, Tot. Qty GPM BHP Motor Eff. Drive ! Pump I Eff. Control packaged DX 2 102,500 0.0 80%AFUE 106,000 75,20 10.1 EER INo Economizer none, Ii i I I ' ; D W BOILER Energy Factor Standby Loss or Pilot TANK INSUL.i I Ext. R -Val. j System Name System Type Distribution Type !Qty Rated Input Vol. 1 or Recovery (Gals.) + Efficiency !standard Gas 50 gal or Small Gas Standard 0 40,000 501 0.53 n/a 121 ! i CENTRAL SYSTEM RATINGS CENTRAL SYSTEM FAN SUMMARY HEATING FAN COOLING S stem Name System Type Qtv. Output Aux. kW Eff. Output Sensible Efficiency ! Economizer Type CARRIER 48HJD009501 packaged DX 2 102,500 0.0 80%AFUE 106,000 75,20 10.1 EER INo Economizer none, i I I ' ; I ! ! i CENTRAL SYSTEM FAN SUMMARY FAN RETURN FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. CARRIER 48HJD009501 Constant Volume Blow -Through 3,400 2.90 84.0% 97.0% none, i I ' I ! I EneravPro 3.1 By EnemySoft User Number. 2655 Job Number. Paae:21 of 31 1 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH 22 PROJECT NAME La Quinta Grill Offices I DATE 5/22/2003 VAV TERMINAL BOX TERMINAL FAN Min. CFM Reheat Coil Motor Drive System Type Qfty. Ratio TYPe DeltaT CFM BHP Eff. Eff. I EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Paae:22 of 31 1 Room Name Qty. CFM BHP Motor Eff. DriveMotor Eff. Room Name q . CFM BHP Eff. Drive Eff. I EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Paae:22 of 31 1 (MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE La Quinta Grill Offices I 5/22/2003 MECHANICAL VENTILATION o a a o 0 0© a a a a ZONE/SYSTEM Offices Building One Offices Building Two AREA BASIS COND. AREA (SF) CFM PER SF MIN. CFM (B x C) 2,977 0.15 447 2,977 0.15 447 OCCUPANCY BASIS NO. CFM MIN. OF PER CFM PEOPLE PERSON (EXF) Total Total VAV MIN. RATH C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). I EnergvPro 3.1 By EnergySoft User Number. 2655 Job Number. Paae:23 of 31 1 MECHANICAL SIZING AND FAN POWER MECH-4 PROJECT NAME DATE La Quinta Grill Offices 5/22/2003 SYSTEM NAME FLOOR AREA Building One 2,977 NOTE: Provide one copy of this form for each mechanical system when using the Prescriptive Approach. SIZING AND EQUIPMENT SELECTION 1. DESIGN CONDITIONS: - OUTDOOR DRY BULB TEMPERATURE - OUTDOOR WET BULB TEMPERATURE - INDOOR, DRY BULB TEMPERATURE 2. SIZING: - DESIGN OUTDOOR AIR - ROOM LOADS - RETURN VENTED LIGHTING RETURN AIR DUCTS - RETURN FAN - SUPPLY FAN - SUPPLY DUCTS SAFETY/ WARM-UP FACTOR (APPENDIX C) (APPENDIX C) SEE ASHRAE CHAPTER 8, 1993 OR APPENDIX B 496 CFM (MECH 3; COLUMN 1) TOTALS MAXIMUM ADJUSTED LOAD (TOTALS FROM ABOVE x SAFETY / WARM-UP FACTOR) 3. SELECTION: INSTALLED EQUIPMENT CAPACITY (ADJUSTED FOR DESIGN CONDITIONS) IF INSTALLED CAPACITY EXCEEDS MAXIMUM ADJUSTED LOAD, EXPLAIN COOLING HEATING 112 OF 26 OF 78 OF 74 OF 70 OF 19,881 23,287 1 16,177 n/ 809 0 0 1 809 41,082 1.43 58,747 45,506 0 2,2751 0 0 2,275 69,938 1.21 84,625 74,459 1 102,500 Btu / Hr Btu / Hr FAN POWER CONSUMPTION FA] a © a a a a DESIGN EFFICIENCY NUMBER PEAK WATTS CFM FAN DESCRIPTION BRAKE HP MOTOR DRIVE OF FANS B x E x 746 / (C X D (Supply Fans) Supply Fan 2.900 84.0% 97.0% 1 2,655 3,400 TOTALS 2 655 F-3,4001 NOTE: Include only fan systems exceeding 25 HP (see Section 144). Total Fan System Power Demand may not exceed 0.8 Watts/cfm for TOTAL FAN SYSTEM constant volume systems or 1.25 Watts/cfm for VAV systems. POWER DEMAND 0.781 WATTS / CFM Col. F I Col. G EnergyPro 3.1 By EnergySoft User Number 2655 Job Number. Page:24 of 31 MECHANICAL SIZING AND FAN POWER MECH-4 PROJECT NAME DATE La Quinta Grill Offices 5/22/2003 SYSTEM NAME FLOOR AREA Building Two 2,977 NOTE: Provide one copy of this form for each mechanical system when using the Prescriptive Approach. SIZING AND E UIPMENT SELECTION 1. DESIGN CONDITIONS: - OUTDOOR DRY BULB TEMPERATURE - OUTDOOR WET BULB TEMPERATURE - INDOOR, DRY BULB TEMPERATURE 2. SIZING: - DESIGN OUTDOOR AIR - ROOM LOADS -RETURN VENTED LIGHTING - RETURN AIR DUCTS - RETURN FAN - SUPPLY FAN - SUPPLY DUCTS SAFETY/ WARM-UP FACTOR (APPENDIX C) (APPENDIX C) SEE ASHRAE CHAPTER 8, 1993 OR APPENDIX B 496 CFM (MECH 3; COLUMN 1) TOTALS MAXIMUM ADJUSTED LOAD (TOTALS FROM ABOVE x SAFETY / WARM-UP FACTOR) 3. SELECTION: INSTALLED EQUIPMENT CAPACITY (ADJUSTED FOR DESIGN CONDITIONS) IF INSTALLED CAPACITY EXCEEDS MAXIMUM ADJUSTED LOAD, EXPLAIN COOLING HEATING 112 OF 26 OF 78 OF 741 OF 70 OF 19,884 23,292 45,094 15,45 0 n/a 2,255 77 0 0 [EE2,250 0 97.0% 77 69,492 40,287 1.2 1.43 84,086 57,610 74,4531 1 102,500 Btu / Hr Btu / Hr a a a o a a DESIGN EFFICIENCY NUMBER PEAK WATTS CFM FAN DESCRIPTION BRAKE HP MOTOR DRIVE OF FANS B x E x 746 / (C X D (Supply Fans) Supply Fan 2.900 84.0% 97.0% 1 2,655 3,400 TOTALS 2 655 3 400 NOTE: Include only fan systems exceeding 25 HP (see Section 144). Total Fan System Power Demand may not exceed 0.8 Watts/cfm for TOTAL FAN SYSTEM constant volume systems or 1.25 Watts/cfm for VAV systems. POWER DEMAND 0.781 WATTS / CFM Col. F / Col. G EnergyPro 3.1 By Energysoft User Number 2655 Job Number. Page:25 of 31 (MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME La Quinta Grill Offices DATE 5/22/2003 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies CI §111 Any appliance for which there Is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have.a pilot light. II § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees ` Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. �i § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: FX§ 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours If power is Interrupted; or ,AJ § 122(e)1B An occupancy sensor to control the operating period of the system; or ' i 0 § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback ' heating and/or a setup cooling thermostat setpoint. ❑' § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with '. Isolation devices, such as valves or dampers, that allow the supply of heating or j cooling to be setback or shut off independently of other Isolation areas; and shall be controlled by a time control device as described above. ❑ § 122(a&b) Each space conditioning system shall be controlled by an Individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control _ shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. a§ 122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. ❑ § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. I EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:26 of 31 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE i La Quinta Grill Offices 5/22/2003 Description IDesigner !Enforcement Ventilation j U §121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. C§ 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. FX�I § 121(f)1 Air Balancing: The system shall be balanced In accordance with the National j Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or I Associated Air Balance Council (AABC) National Standards (1989); or �I § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous i basis and displaying that quantity on a readily accessible display divice; or i F § 121(f)4 Another method approved by the Commission. l I Service Water Heating Systems IA I § 113(b)2 If a circulating hot water system is Installed, It shall have a control capable of automatically turning off the circulating pump(s) when hot water Is not required. � I l^ i § 113(b)3B Lavatories In restrooms of public facilities shall be equipped with controls to limit the r outlet temperature to 110 degrees F. § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). I EnerovPro 3.1 8v EnemySoft User Number. 2655 Job Number. Paoe:27 of 31 I ROOM HEATING PEAK LOADS Project Title La Quinta Grill Offices Room Information Room Name Floor Area Indoor Dry Bulb Temperature Conduction Offices Time of Peak 2,977 Outdoor Dry Bulb Temperature 70OF Area U -Value OT of Jan 12 am i 260F Btu/hr Slab -On -Grade perimeter = 63.0 X X 44.5 = 2,804 Premier Structural Building Panels 1,405.0 X 0.0487 X 44.01 = 3,01 Solid WoQdD 40.0 X 0.3872 X 44.01 = 682 Mtl Thermal Brk Unctd Default 191.0 X 0.7100 X 44.01 = 5,9671 R-3S_Boof (R 3A 9YJA 1 2,977.0 X 0.0284 X44.0 = 3,714 X X I = X X i X x = X X = X X X x = X X X X X X X X X X X X X X = X X X X = X X X X XX x X = X X J i X X X X = X X X X XX X X X X X X X X X X X X X X X X X X Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 16 177177 Infiltration: L Schedule 1.00 x 1.072 x 2 977 x 10.00 x 0.00 / 6o] x 0 = 01 Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,177 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 28 of 31 ROOM HEATING PEAK LOADS Project Title Date La Quinta Grill Offices 15/22/2003 IRoom intormation uesign conditions I Room Name Offices) Time of Peak Jan 12 am Floor Area 2,9771 Outdoor Dry Bulb Temperature 260F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr slab-un-uraae perimeter = 63.0 x x 1 44.5; = 2.804 i Premier Structural Building Panels 1 430.0 x 0.0487 x44.0 = 3,0651 40.0 x 0.3872 X 44.0 = 682; Mtl Thermal Brk Unctd Default 166.0 X 0.7100 X 44.01 = I 5,1861 R38 Roof (R.3 2,977.0 x 0.0284 X 44.0 = 3 714! X x X x = 1 X x c I ! X. X x X ! I X x X X 1 X X i X X X X X X = X X X X x X X X —I X X = x X X x = 1 X X X X x X ! X x X X x X X X X X X X X X = ! X X X X X X xX X x Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 15 450 Infiltration: 1 1.001 x x 2 977 x 10.00 x 60] x 44 ehedule Air Sensible Area Ceiling Height ACH 1.072 Fraction DT TOTAL HOURLY HEAT LOSS FOR ROOM 15,450 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page: 29 of 31 ROOM COOLING PEAK LOADS Project Title Date La Quinta Grill Offices 5/22/2003 ROOM INFORMATION DESIGN CONDITIONS ;Room Name Offices Time of Peak Jul 3 pm 'Floor Area 2,977 Outdoor Dry Bulb Temperature 112 OF ,Indoor Dry Bulb Temperature 74'' Outdoor Wet Bulb Temperature 78 OF Conduction Premier Structural Building Panels Solid Wood Door Mtl Thermal Brk Unctd Default Panels Area X U -Value 400.0 X 0.0487 40.0 X 0.3872 175.01 X 0.7100 353.01 X 0.0487 324.0 X _0.0487 16.0 X 0.7100 328.0 X 0.0487 2,977. X 0.0284 I x (East) 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (•) denote conduction through an interior surface to another room. Solar Gain DETD 1 X 37.0 X 37.2 X 27.0 X 39.21 X 40.11 X 27.01' X 57.41 X 64.0 X Page Total Orientation Area X x X x x x X x X X SGF X X x X X X X X X X SC Weighting x X x x X x X X X X Factor = = = = = = = = = (North) 100.0 41 0.7011 0.797 (East) 25.0 41 0.701 1.461 (South) 16.0 42 0.701 0.783 (West) 50.0 169 0.7011 Page Total Btu/hr 721' 577; 3,357 674i 6321 307! 917 5.399i 12 5831 Btu/hr I 2.291 10501 369 2,331 I Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor Lights A x 2,977 x 0.833 Watts/sqft x 3.413 Btuh/Waft x 0.998 = 8,450 ipccu ants X 2,977 X 250 Btuh/oCc. / 9 sqft/occ. x 1.00 = 8,269 Receptacle X 2,977 X 1.000 Wafts/sqft x 3.413 Btuh/Watt x 1.00 = 10161, Process (x 2,977 X 0.000 Wafts/sqft x 3.413 BtuhlWatt X 1.00 = 0 Infiltration: I 1.0o x 1.072 x 2 977 x 10.0o x o.00 / 601 x 38 = 0 chedule Air Sensible Area Ceiling Height ACH T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 45,5061 Sched. Btu/hr Latent Gain Frac. Area Heat Gain �Occu ants 1.00 x 2,977 x 2001 Btuh/occ. / 90 sqft/occ. = io IRece tacle 1.oD x x Watts/sgft x Btuh/Watt rP ocess 1.00 x 2,977 x 0.000 Wafts/sqft x 3.413 Btuh/Watt = Infiltration: 1 0o x� x 2,977 x x o_oo / 60] x � 1 chedule Air Latent Area Ceiling Height ACH zslw 0 I 0. ROOM COOLING PEAK LOADS Title Date I La Quinta Grill Offices 1 5/22/2003 I !Room Name Offices Time of Peak Jul 2 p jFloor Area 2,977 Outdoor Dry Bulb Temperature 111 cl� jlndoor Dry Bulb Temperature 740F Outdoor Wet Bulb Temperature 77 O Conduction Area U -Value DETD Btu/hr Premier Structural Building Panels 400.0 X 0.0487 X 38.81 = 755 Solid Wood Door 40.0 X 0.3872 X 40.41 = ! 626 MtI Thermal Brk Unctd Default 166.0 X 0.7100 X 25.8 = 3,0451 Premier Structural Building Panels I 378.0 X 0.0487 X 41.31 = 7611 Premier Structural Building Panels 324.0 X 0.04871 X 51.4 = 811 Premier Structural Buildin-q Panels 328.0 X 0.04871 X 1 36.31 = 581 R-38 Roof R.38.2x14.16 2 977.0 X F:::::0.02841 X 67.5 _ 5,696 X X I X l x I= I -moi 1. Design Equivalent Temperature Difference (DETD) Page Total F12 2751 Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window I i Weighting Orientation Area SGF Sc Factor (East) i 100.0 X46 x 0.701 X 1.3531 = (Vilest) 16.0 X 81 X 0.701 x 0.545 = (North) 50.0 x 46 x 0.701 x 0.701 = X X x = X X X 1= x x X x X x = X x X X x X = X X x Page Total Btulhr 4,365 496 I 1,130 I 5,9911 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor VU hts 1.0 x 2,977 x 0.833 Watts/sgft x 3.411 BtuhlWatt x o.9981 ,44 ccuants 1.0 X 2,977 x 2501 Btuh/occ. / 9 Sgft/oCC. X1.00 = 8,269 eceptacle 1.0 X 2,977 X 1.000 Wafts/sq ft X 3.41 Btuh/Watt X 1.00 = 10,161 rocess 1.0 x 2,977 X 0.00E�--0 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 0 Infiltration:Lhedule 1.00 x 1.072 x 2 977 x 10.00 x 0.00 /601 x 38 = 0 Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 45,143 Sched. Btu/hr Latent Gain Frac. Area Heat Gain ccu ants 1.00 x 2 977 x 2001 Btuh/occ. / 90 sgft/occ. = 6 616 ece tacle 1.00 x x Wattslsgft x Btuh/Watt = rocess 1.00 x 2,977 x 0.000 Watts/sqft x 3.413 Btuh/Watt = X01 Infiltration: x 4,Bo6 x 2.977 x 100o x /60] x oDD _ BOJ chedule Air Latent Area Ceiling Height ACH pVy TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6616 I EnergyPro 3.1 By EnergySoft User Number. 2655 Page: 31 of 31