Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
0007-211 (SFD) Title 24
v FROM Christensen/T-24/CABEC FAX NO. 909 763 0522 Jun. 28 2000 06:28PM P15 Carole Christensen, Certified EnergyAnalyst Title44 Energy Calculations dune 28, 2000 ENERGY CALCULATIONS FOR: Leridel Ventures, Inc. P.O. Box 450 La:Qui:nta, CA 92253-0450 PROJECT: Pian La Quinta -.Fast 1397 sq.ft La'Quinta, CA Stimdard proposed Compliance 61.92 61.20 +0.72 Fast orientation CTG -:15 13.8% fenestration Dual Aluminum fenestration, Philips -or better., Std. Drape 'Walls:R-13+1"Falcon; Roof R-38; Duct R-4.2 AF UE 80%, SEER 10.0 One 40 gal gas water heater, EF. 60 Micropas v5.10 Table of Contents '= CF -1R MF -1 R. C -2R 3-R 1-IVAC Fenestration Specifications 4,496 LakeQl7mn Drive, iU1UW^ CA.9zZV? ' 1-800-735-8152 Member CABP,C - CaAfivmia Associadon u!'13ui/ding F7cgV C•oasu/tmrs 1 FROM : Christensen/T-24/CABEC :FAX NO. : 909 763 0522• Jun. 28 2000 06:29PM P16 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -ZR Project Title........... Plan La Uinta East Q Project Address........ Date..06/28/00 18:54:10 ******,� La Quinta, CA *v5.10* Documentation Author... Carole Christensen ******* B u i 1 d ing Permit Carole Christensen 47-596 Lake Canyon Drive Plan ..nec Date Aguanga, CA 92536 80:0-735?8152 Fie C ec Date Climate Zone. 15 Compliance Method...... -'M1CR0PAS5• v5 .10 for 1998 Standards by Fnrrrrr�mn= 7nr. MiCROPAS5 v5.10 File-LAQINTAE Wth CTZ15S92 Program-FORMCF-1R User#.-MP1017 User -Carole Christensen: Run-Drp60.10R13+PW38,4 40EF58 Component , Type GENERAL INFORMATION Conditioned Floor Area..... 1397 sf Building Type..:.... .,.... Single Family Detached 'Construction Type „ ... New Building Front Orientation, Front Facing 90 deg (E) Number of Dwelling units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage..,....... 13.8 b of floor area Average Glazing:U-value.... 0.77 Btu/hr-ef-F Average Glazing SHGC...I... 0.68 Average Ceili'ng Height..... 9.5"ft :Frame Type wall Wood wall " wood Roof Wood Door • n/a SlabEdge n/a S1abEdge n/a Orientation Window Front (E) Window Left (S) Door Left (S) Window Left " (S) Window Back (W) Window Back (W) Door Back (W) Window- Right (N) . Window Right. (N) Window. Might .(N) ;.BUILDING SHELL INSULATION Cavity Sheathing Total A6sembly R -value R -value R -value U -value Location/Comments R-13 R-0 R-13 0.060 front, back, right R=13 R-0 R-13- 0.0.86 to garage R-11' R-27 R-38 0.025 Attic R-0 ;_ R-n/a R-0 0.330 solid woodi. R-0 R-n/a Standard F2'=0.720 to outside_ R_-0 R-n/a Standard F2-=.0.;500 to garage . . FENESTRAT I`ON Over - Area:': U- Interior Exterior hang/ (sf).> Value SHGC Shading Shading` Fins 15.8 0.720 0.670 Standard Standard None 12.0 0.720 0.670 Standard Standard None 40.0 0.850 0.700 Standard Standard None 16.0 0.720 0.670 Standard Standard None 20.0 0.720 0.670 Standard Standard None 6.0 0-77.0 0.670 Standard Standard None 40.0 0.850 0.700 Standard Standard Nome 6.0 0.720 0.670 Standard Standard Nene 10.0- 0.720 0.670 Standard = Standard: None 27.0' 0.720 0.670 Standard Standard: Ncne :FROVI Christensen%T-24:CABEC FAX PJO. : 909 763 0522 Jun. .28 2000 06:29PM P17 :CERTIFICATE OF COMPLIP.NCE : RESIDEN?'IAL Page 2 - CF 1,;R Project Title ........... Plan La Quinta East Date..06/28/00 18:54;10 MICROPAS5 v5.10 File-LAQINTAE Wth-CTZ15S92 Program-FORM CF-1R User#-MP1017 User-Carole Christensen Run-Drp80.l0R13+PW38.4 40EFSS SLAB .SURFACES Area Slab Type.. Standard, Slab 1397 HVAC SYSTEMS minimum Duct Duct Tested Duct ACOA. Equipment Type Efficiency Location R-value Leakage :Manual Thermostat D. Type Furnace 0.800 AFUE Attic R-4.2 No No Setback ACSp1it 10..00 SEER Attic R-4.2 No No Setback WATER HEATING SYSTEMS Number Tank External in Energy: Size Iasalation Tank.Type Heater :Type Distribution Type System Factor (gal) R-value Storage Gas' Standard 1 0.60 40 R- n/?' REMARKS ' -Pfiiips fenestration or better FROM : ChriSten5en/T-24/CABEC FAX NO. 909 763 0522 Jun. 28 2000 06:30PM P18 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Plan La Quinta East Date,. 06/28/00 18:54:10 MICROPASS v5.14 File-LAQINTAE Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40EF58 COMPLIANCE STATEMENT. This certificate of -.compliance lists the buildingfeatures and perfor�iance specifications: needed'. to comply with Title -24, Parts 1 and. 6 of • the California Code of Regulations, and the administrative. regulations: to - implement thein:: This. certificate has •been signed by the individual with overall design responsibility, Wheii this certificate of compliance is submitted for a single building plan to be built in multiple orientations, ary shading feature that is varied ie indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCJMENTATION AUTHOR Name.... A.P.Lench, `II, President Name..... Carole Christensen Company. Lendel Ventures, Inc. Company. Carole Christensen Address. P.O. Box 450 1 Address. 47-596 Lake Canyon Drive La Quinta, CA 92253 Aguanga, CA 92536 Phone... (760) 64-1866 Phone... 800-735-8152 License. #638 5 J _ Signed.. Signed.. ate ate FORCEMENT A NCY `I. _—a fi pd Name.... Title... Agency.. Phone... Signed. ate Certi4ied •�t+ar9Y Analyst pe CatofO C9�risLe Ft 8 99E239 � C k Q £ Fr,,rgy ccs,-�linno Cdtfomia Assmtc i*' of t3uilc3lrng . FROM :.Christensen/T-24/CABEC FAX NO. 909 763 0522 Jun. 28 2000 06:31PM P19 MANDATORY MEASURES CHECKLIST: RESIDENTIAL; (Page I of 2) MT -1R Note: I.owrisc residential buildings subject to the Standards must -contain these measures regardless of the compliance approach used. ms marked with an asterisk (•) may be superseded by more stringent compliance requirement listed on the Certificate of t bmpliance. When this checklist is incorporated into.thc permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this Checklist only. Instructions: Check or initial applicable boxes when.completed or enter NIA if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures: . ' §150(a): Minimum R•19 ceiling insulation. § I50(b): Loose fill insulation manufacturer's labeled R•Value. ' §150W., Minimum R-13 wall insulation in wood framed walls or equivulent U -value in nietal frame walls.. (does not apply to exterior mass,walls). • : § 150(d): Minimum R. 13 raised floor insulation in framed floors. N § I50(1) : Slab edge insulation • water absorption rate no greater than 0.3%, water vapor tranamission. rate no greater than 2.0 pemt/inch. § 118: Insulation specified or inaAlcd meets Insulation Quality standards. Indicate type and form. § 116-11: Fenestration Products, Extcrior Doors, and Infiltration/Exfiltration Controls t. Doors and windows beewecn conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestradon products (except field-fabricated)have label with certified U -value, certified Solar Heat Gain Coefficient (SNGC), and infiltration certification. 3. Exterior doors and windows weaffientripped; all joints and penetrations caulked and sealed. §154•x, Vapor barriers mandtstory in Climate Zones 14 and lb only, , § 150(0: Special infiltration barrier installed to comply with § 151 meets Commission quality startdaids, §150(e): Installation of Fireplaces, -Decorative Gas Appliances and Gas Logs. I. Masonry and fictory•built fireplaces have; v •a Closeable metai or glass door b. Outside air ihtake with damper and control is c. Flue damper -and control 2. No wricinuous btim;ng gas pilot lights allowed. Space*Conditioning, Water Heating and Plumbing System Measures: '§10+13: HVAC equipment, .,rater heaters• showerheads and faucets certified by the Commission, I § 150(h): Heating and/or cooling loads calculated in accordance vith ASHRAE, SMACNA or ACCA. , §:50(i); Setback thermostat on 311 applicable heating and/or cooiirg systems. t 15 Pipe and tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal msistasice of R•12 or greater. I 2. First 5 feet of pipes closest to water heater tank, non•mcirculating:systems, insulated (R-4 or greater) : Back-up funks for solar system, unfired storage tanks, or other indirect hot water tanks have R• 12 - i external insulation -or R-16 combined intemallextcma* l insulation. 4, All buried or exposed piping insulated in recirculating sections of hot water systems. t Y ( ng system piping below 55' P insulated. L 6, Piping insulated between heating source and indirect hot water tank ✓ 1 _ July 1, 1999 FROM Christensen/T-24/CABEC FAX:NO. 909 763 0522 Jun. 28 2000 06:31PM: P20 MANDATORY MEASURES CHECKLIST: USIDENTIAI, (Page 2 of 2) W -IR Note: Lowrisc residential buildings subject to the Standards"must Contain these measures regardless Of the compliance approach used.. Items marked with an asterisk (•) may be superseded by more stringent complianet requirements listed on the Certificate of Comp:ianee. When this checklist is incorporated into the permit documents, the fcatums noted shall be considered by all parties as inimmum component pci fomtancc specifications for the m9ndetory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCiZ.FTION DESIGNER. ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) • 51 Men): Oucs and Fans " 1. All dt:cts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBG 1997 UMC sections 501 and 603; ducts insulated to a miiimum installed Ra.2 or ducts enclosed entireiy within conditioned space. Openings shall be scaled with mastic, tape, aerosol sealant or other duct closure system that meets the applicable requiremetris of UL1$1_, ULI81A, or ULL91B and other applicable specified tests for longevity given in $150(m).. " 2. Exhaust fan systems have back draft or automatic dampen. 3. Gray icy ventilating systems serving conditioned space have either automatic or readily accessible; manually operated dampers, g114- Pool and Spa Bleating Systems and Equipment, I System is certified with 78% thermal efficiency, on-off switch, weaiherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: Al least 36" ol'pipe between filter and heater for future solar healing. b. Cover for outdoor pools or outdoor spas. 3 Pool "system has directional inlets and a circulation pump time switch, 2/ Gas tired central furnaces, pool heaters, spa heaters or household cooking applianceshave no' continuously burning pilot light. (Exception; Non -electrical cooking appliances with pilot < 150 But/hr) r/ Lighting ,Measures: . is a 1501.0.: Luit inaires for general lighting in kitchens shall have tamps with an efficacy of 40 iurncnslwatt or greater for general lighting in kitchens, This generdl lighting shall be controlled by a switch -on a readily accessible lighting control panelist an entrance to the kitchen. i 5041 3.: Rooms with a shower or bathtub must either have at least one.luminaira"with lamps with an eIT-. acy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to ' -and allowed in 4150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approve 1. _1 July 1, 1999- FROM ChriStenSen/T=24/CABEC FAX NO. 90`-7 763 0522 :.Jun. 28 2000 06:32PM P21 COMPUTER METHOD SUMMARY Page 1 Project Title.......... Plan La Quinta East Date ..06/28/00 18:54:1.0 Project Address........ ******* La Quinta, CA *V5.10* i Documentation Author... Carole Christensen ******* BUi I ding ermit Carole Christensen 47-596 Lake Canyon Drive Plan C ec Date Aguanga, CA 92536 800-735-8152 Field C ec Date Climate Zone. 15 )mpliance Method........ MICROPAS5:V5.10 for 199.8 Standards by:Enercomp, rnc. MICRC) PAS5 '5.10 File-LAQINTAF. Wrh-CTZ15S92 Program -'FORM C -2R User#:-MP10.17. User -Carole Christensen Run-Drp80.10R13+PW38.4-c0EF58 MFCROPASS. ENERGY USE SUMMARY. Building Type......... ... Energy: Use Standard Proposed Compliance (kBtu/s`f -yr) ; Design Design' h?argin Space Heating.......... 2.87 2.13'. 0.74 Space Cooling.......... 42.48 45.37 -2.89. Water Heating.......... 16.57 i4.31 2.26 Total 61..92 61.81 0.11 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... 1397 sf Building Type......... ... Single Family Detached Construction Type New Building Front Orientation_, Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction_ Type.... Slab On Grade = - Number of Building Zones.., 1 Conditioned Volume......... 13272 cf Slab -On -Grade Area....,.... 1397 sf Glazing Percentage. .. .... 13.8 5 of floor area Average Glazing U -value.... 0,77 Btu/=hr-sf-F'. ;Average Glazing SHGC........ 0.68 Average Ceiling Height...... 9.5 ft BUILDING ZONE IDiFORb1ATIOPd Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area. Leakage Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit HOUSE .Residence 1397 13272 1.0.0. Yes Setback 2.01 Standard- No FROM ChriStenSeri/T-24/CABEC FAX NO. 909 763 0522 Jun. 28 2000 06:33PM P22 COMPUTER METHOD SUMMARY Page 2 C -2R PrniPCt- MICROPAS5 v5.10 File-LAQINTAE Wth-CTZ15S92 Program -FORM C -2R User##-MP1017 User -Carole Christensen Run-Drp80.1OR13*PW38.4 40EF58 PERIMETER LOSSES Length OPAQUE SURFACES Solar Area U- Insul Act Gains Solar Form 3 Location/ Surface .(sf) value R-val Azm Tilt Gains: Reference Comments HOUSE 9 S1abEdge 133 0.720 R-0 110 to outside 1 Wall 69 0.060 13 90 90 Yes W13.2X4.16FA front 2 Wall 280 0.060'13 180 90 Yes_ W13.2X4.16FA 3 Wall 190 0.060 13 270 90 Yes W13.2X4.16FA back 4 Wall. 305 0.060 13 0 90 Yes W13.2X4.16FA right 5 Wall 168 0.086 13 90 90 No -:GWALL.R13 to garage 6 Roof 1397 0:025 38 n/a 0 Yes 'R.38.2X4.24 Attic 7 Door 20 0.330 0 90 90 No :None: solid wood 8 Door 17` 0.330 0 90 90 No None solid wood PERIMETER LOSSES Area Slab Type (sf) HOUSE :Standard Slab 1397 Length F2' Insul Solar Surface (ft) Factor : R-val Gains Location/Comments HOUSE 9 S1abEdge 133 0.720 R-0 110 to outside 10 SlabEdge 20 0.500 R-0 No to garage FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) value SHGC Azm Tilt Type/SHGC Type/SHGC HCUSE 1 Window Front (E) 15.8 0.7420 0.670 90 90: Standard/0.76 Standard/0.68 2 Windowi: Left (S) 12.0 0.720 0.6'70 180' 90': Standard/0.76 Standard/0.68 3 Door Left (S) 40.0 0..850 0.700 180 90 Standard/0.76 Standard/0.68 4 Window Left (S) 16.;0 0.-_720 0.670 180::90. Standard/0.76 Standard/0.68 5 Window_ Back (W) 20.;0 0.720 0.670 270 90= Standard/0.76 Standard/0.66 6'Window- Back (W) 6.'0 C:.720 0.670 270 90 Standard/0.76 8tandard/0.68 7.Door Back (W) 40..0 0.850 0.700 270: 90 Standard/0.76 Standard/0.68 -8 Window Right (N) 6.`0 0.720 0.670 0 90,;'Standard/0.76 Standard/0.68 9 Window;': Right .(N) 10.'0 0.720 0.670 0 90 Standard/0.76 Standar6/0.68 10: Window. Right (N) 27.;0 0.7)20 0.670 0 90 Standard/0.76 Standard/0.68 SLAB SURFACES Area Slab Type (sf) HOUSE :Standard Slab 1397 FROM ChristensenlT-24/CABEC FAX NO. 909.763 0522 Jun. 28 2000 06:33PM :P23 COMPUTER METHOD SUMMARY Page 3 2R MICROPASS v5.10 File-LAQINTAE Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40EF58 � :HVAC SYSTEMS Minimum Duct Duct'Tested Duct ACCA Duct. Sys te"m..Type E f f.ic iency Locat ior_ R-.traliz= Leakage.; Manual D, 'Ef f HOUSE Furnace 0.8.00 AFUE Attic R-4.2 No No 0.743 ACSplit 10.00 SEER Attic R-4..2 No No 0.596 WATER HEATING SYSTEMS Number Tank Externa' = in Energy Size Insulatlon Tank Type Heater Type Distribution Type System `actor' (gal) R -value Storage Gas! Standard 1 0.60 40 R- nfa REMARKS Philips fenestration or bettet FROM ChristenseniT-24iCABEC FAX NO. 909 763 0522 Jun. 28 2000 06:34PM P24 CQNSTRUCTION ASSEMBLY Page 1 3R. Project Title.......... Plan La Quinta East Date..06/28/00 18:54:10 MICROPA85 v5:10 File-LAQINTAE Wth-CTZ15S92 Program -FORM -3R User#-MP1017 User -Carole Christensen Run-Drp80.1OR13+PW38.4 40EF58 Parallel Path Method Reference Name . W13.2X4.16FA Description ... Wall R-13 2x4 16cc Type Wall R -Value ...... 13 Hr-sof-F/Btu Framing Material ...... PIR.2X4. Type: .... Wood Description .. 2x4 fir Spacing ....... 15 inches on center Framing Frac.. 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -'Value O. FILM.EX Exterior air film: winter value 0.17 0.17 1.. STUCCO.0.88 0.875 in stucco 0.17 O.1-7 2. R 4.61 RIGID R-4.61 Insulated Sheathing 4.61 4.61 3. BLDG.PAPER Building paper (felt) 0.06 0.06 4c. BATT. R13 R-13 batt insul (cavity = 3.5 in) 13.00 -- 4f. FIR.2X4 2x4 fir -- 3:46 5. GYP.0.50 0.50 in gypsum or plaster board 0.45 01:45 I. FILM.IN.WLL Inside air film: -heat sideways 0.68 0-:68 Total Unadjusted R -;Values 19.15_ 9:.61 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U. -Value: (1 / 19.15 x 0.85) + (1 / 9.61 x 0.15) = 0.060 Btu/hr-s£-F Total R -Value: 1 0.060 = .16.66 hr-sf-F/Btu FROM Christensen/T-24/CABEC FAX NO. 909 763 0522 Jun. 28 2000 06:34PM P25 CONSTRUCTION ASSEMBLY Page 2 3R MICROPAS5 x5.10 File-LAQINTAE Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run-Drp80.10R13+PW38.4 40EF58 Parallel Path Method Reference Name:. GWALL.R13 Description .... Wall. R-13 2x4.16oC' Type Wall R -Value 13 Hr-sf-F/Btu Framing Material .. FIR:2X4 Type .. ..:.. Wood Description 2x4 fir Spacing 16 inches on Center Framing Frac.. 0.15 LIST OF CONSTRUCTION .CbMPONENTMTS Material Cavity Frame Name Description R-Vaiue R -Value 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. -GYP.0.50 0.50 in:gyjpsum.or plaster board 0,45 0.45 3c. BATT_R1.3 R-13 batt insul (cavity = 3.5 in) 13:00 -- 3f•. FIR.2X4 2x4 fir - 3.46 4. GYP.0.50 0.50 in,-Typsum or plaster board 0 45 0.45 I. FILM.IN.WLL Inside.4ir filmy heat sideways 0:68 0.68 Total Unadjusted ,,R-Values. 14:75 5.21 FRAMING_ ADJUSTMENT CALCULATION Cavity Framing- Total U -Value: (1. / 14.75 x 0.88) l (1 / 5.21. X 0.15) = 0.086 Btu/lir-sf.-F Total R -Value: 1 / 0.066 11.58 hr-sf-F/Btu FROM Christensen:T=24/CABEC FAX, NO. 909 763 0522 Jun. 28 2000 06:35RM P26 CONSTRUCTION ASSEMBLY Page 3 3R Project Title.:........ Plan La Quinta East Date..06/28/00 18:54:10 MICROPAS5 v5.10 File-LAQINTA,E Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen Run-Drp80.1OR13+PW38.4 40EF58 Parallel Path Method :Reference. Name R -38.2X4.24 De:scriptibn .... Roof R-38 2X4-24oc Type ........... Roof R -Value .......: 38 Hr-sf-F/Btu Framing Material FIR.:2X4 Type ..... Wood Description .. 2x4 fir Spacing .... 24 inches on center Framing Frac.. 0.07 1 1 • �xeccn or c:onsr_ruccicn HssemAly. LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. SHNGL.ASPHLT Asphalt shingle roofing 0.44 _0.44 2. BLDG.PAPER Building paper (felt) 0.. O6 0.06 3. PLY.0.50. 0.50 in plywood 0.62 0.62 4. AIR.RF-.3.50 3.5 in & greater air space: heat flow up 0.80 0.80 5. BATT.R27.0 R-27'batt insulation 27..Q0 27.00 6c. BATT.Rll.0 R-11` batt insul (cavity > 3.5 in) 11:©_0 -- 6f. FIR.2XT 2x4 fir' -- 3.406 7. GYP. 6 . 50 0..50 -in gypsum or plaster- board = -0.45 0 .45 I. FILM:IN.RF Inside air film: heat flow straight up 0.6.1 0.61 Total Unadjusted R -Values :41.15 33.62 FRAMING ADJUSTMENT CALCULATION Cavity Framing', Total U -Value: (1 / _ 41.15 x 0.92) + (1. / 33.62 x 0.07) _ _ 0.025 Btu/hr-sf-F Total. R -Value: 1 / 0.025. = 40.51 hr-sf-F/Btu FROM Christensen/T-24/CABEC FAX N0. :•909 763 0522 Am. 28 2000 06:36PM P27 :HVAC SIZING Page 1 HVAC Project Title..... .... Plan La Quinta East Date..06/28/00 18:54:=0 Project Address........ ******* La Quinta, CA. *v5.10* Documentation Author... Carole Christensen ****.*** bui ing Permit . Carole Christensen 47-596 Lake Canyon Drive Plan C ec Date Aguanga, CA. 92536 800-735-8152 F-i�,c ec s Date Climate Zone. 15 Compliance Method.. , MTCROPAS5 v5.10 far l OAR fian-Tarr7c Ile- L+.,-,,...-,.,- T MICROPAS5 v5..1d File -LAQINTAE- Wth-CTZ15S92 °Program -HVAC SIZING; ...User#-MP1017 User -Carole Christensen Rttn-Drp80.10R13+PW38.4 40EFS8 GENERAL INFORMATION Floor Area..... 1397 S Volume.. .... ............. 13272 cf - Front Orientation.......... Front Facing 90 deg '(E) Siz.ira Location.. . ........... PALM DESERT Latitude .................... '33.7 degrees. Winter Outside Design.....: 32 F Winter Inside Design:...... 70 F Summer. Outside Design... 112 F Summer Inside Design....... 78 F Summer Range. 34:F Interior Shading Used....:. No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction ....... 0.20 HEATING AND COOLING LOAD.SUMMARY Description Opaque Conduction and -Solar ...... Glazing Conduction....... ...... :Glazing Solar........ Infiltration......... ........ Inte+nal Gain........:......... Ducts............................ Sensible Load. .... Latent Load........... .......... Heating (Btuh) 8270: 5670 n:/ a 7008 n:/ a 2095 23 043 `. n/a Cooling (Stuh) 4120 5073 7175 4638 2550 2356 25913 5183. Minimum Total Load 23043, 31095 Note: The loads shown are only one of the criteria affecting the - selection of HVAC equipment. Other relevant. design factors such as air flow requirements,' outside air, outdoor design temperatures, coil sizing,- availability izing;availability of equipment,_ouersizing safety margin, etc-., must also be considered. It is the HVAC designer'.s responsibility to consider all factors when selecting. the HVAC equipment. -FROM Christensen/T-24/CABEC FAX NO. 909 763 0522 Jun. 28 2000 06:36PM P28 • o8!OJ!�9 14:42 F.;Y 2;9P85003a �drkaciajgupyori � 00z , mo, L m," 7.99 240 5r� win . 240 HS HOrixOntai Slider: Cie�r/AIrlCleas ,72 .67 w/ Grills ..61 . Ctetr/dFSCIVCltir .70 67 w/ Grids ,61 Clear/I,0W Dear .57 .38 Grids .35 Cir/LcwE/Arg/Clr, .53 .38 ' w/ Gilds .3$ 'a40SH 57ngjt Hung Gear/Air/Ciear .72. 6; W/ Grids .61. Clear/Argon/Clwr .70 ,bi W/ Grids .61 Clear2,owE/Clwr . .87 38 w/ Grids .35 Cl rIL• OWE/Arg/Cir .53 .38 w/ Grids .3R .240P: Picture Window Clear/Atr/Clear .63 �2 w; Grids .66 Clear/Argon/Clur _ .60 _ ` .12 w/ Grids .66 C tAr/LowElCkar .45: .40 W/ Grids ,37 Clr/LoMFJArZ/C1r .41 .40 Philips Products uses SFectrally .Scleccue Lmo.E Coatings