13-1232 (SFD) Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: Coronel Enterprises - Plan 1600 - East Orientation 51885 Avenida Bermudas / A.P.N.: 773-184-018 La Quinta, Ca 92253 Project Designer: Coronel Enterprises 42760 Madio Street Indio, Ca 92201 760.775.1234 Report Prepared by: Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 Job Number: LQ080113 Date: r--� 11/6/201 The EnergyPro computer program has been used to perform the calculations sum authorized by the California Energy Commission for use with both the Resident This program developed by EnergySoft, l RECEIVED NOV 0 8 2013 CITY OF LA QUINTA wrlMd�fTDEVELOPMENT CITY OF LA QUINTA BUILDING & SAFETY DEPT. aPPR®�/Ir17 and EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-11-06T16:30:32--- ID 3� f approval and is v Standards. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary 13 CITY OF LA QUINTA BUIL DING & SAFETY DEPT, ` PPr-j0`+dE® FOR CONSTRUCTION DATE -� BY EnergyPro 5.1 by EnergySoft Job Number: ID: LQ080113 Llse u ber. 732 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Coronel Enterprises - Plan 1600 - East Ori Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11/6/2013 Project Address 51885 Avenida Bermudas/A.P.N.: 773-18 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,600 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures --If Yes, ACF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 1, 600 Perim = 0' New Wall Wood Framed R-13 1,787 Ext --R-5.0 New Roof Wood Framed Attic R-38 1,918 Radiant Barrier Venting New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidef ins Shades Status Right (N) 32.0 0.590 0.45 none none Bug Screen New Rear (tM 20.0 0.590 0.45 none none Bug Screen New Rear (Vit) 20.0 0.440 0.24 none none Bug Screen New Rear (V1t) 33.3 0.360 0.35 15.5 15.5/15.5 Bug Screen New Rear (Vloq 10.0 0.440 0.24 15.5 15.5/15.5 Bug Screen New Rear (tM 33.3 0.360 0.35 none none Bug Screen New Left (S) 38.0 0.590 0.45 none none Bug Screen New Left (S) 34.0 0.440 0.24 none none Bug Screen New Front (SE) 8.0 0.590 0.45 none none Bug Screen New Front (SE) 3.7 0.440 0.24 none none Bug Screen New Front (E) 16.0 0.590 0.45 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 8.0 New of WATER HEATING 'r O LA QII I A Qty. Type Gallons Min. Eff I D strib�uti9bh SAFETY DEPT. Status 1 Small Gas 40 0.65 1 A11PtpA'1n"sHH(_)VEDNew FUR CONSTRUCTION DATE By Energ Pro 5.1 by EnergySoft User Number: 5732 RunCode: Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Coronel Enterprises - Plan 1600 - East Orio Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11/6/2013 Project Address 51885 Avenida Bermudas/A.P.N.: 773-18 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,600 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZ]Yes ❑ No HERS Measures -- If Yes, ACF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (E) 7.3 0.440 0.24 none none Bug Screen New Front (E) 20.0 0.360 0.35 15.5 0.0/13.5 Bug Screen New Right (NE) 8.0 0.590 0.45 none none Bug Screen New Right (NE) 3.7 0.440 0.24 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Oty. T peATING Gallons Min. Eff Dis it�iti �M%fi\�� �(XUJ�IMMM�ts DE EOR nn uCT1 Oq Energ Pro 5.1 by Energ Soft User Number: 5732 RunCode: 2013-11-06T16.46W2 _ —M-t_*�ey ge 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Colonel Enterprises - Plan 1600 - East Ofie Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11/6/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 972.0 R' Exposed Slab Floor, 4.000" thick at Whole House HIGH MASS Design - Verify Thermal Mass: 628.0 ftZ Covered Slab Floor, 4.000" thick at Whole House The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. The Roof R-38 Roof Attic w/Radiant Barrier 1/150 Vent Area requires verification. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Coaling System YorkCZB48. PS8CN100.1600cfm includes credit for a 11.4 EER Condenser. A certfed HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC System incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System incorporates HERS vefied Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. CITY np tJU/LD/NG'8,'-� WUINTA SAFFJ)�f 1-Ar--- /. � P RovE FOR ucrloN EnemyPro, 5.1 by EnergySoft User Number: 5732 RunCode: 2013-11-06716:30:32 1 —"'6.-LW80113 Page 5 of 13 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Coronel Enterprises - Plan 1600 - East Odell ❑ Multi Family ❑ Existing+ Addition/Alteration 1111612013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/fe- r Space Heating 4.00 2.95 1.05 Space Cooling 58.15 56.21 1.94 Fans 11.78 14.97 -3.18 Domestic Hot Water 18.62 15.89 2.73 Pumps 0.00 0.00 0.00 Totals 92.55 90.01 2.54 Percent Better Than Standard: 2.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 389 55 Fuel Available at Site: Natural Gas (S) 630 72 Raised Floor Area: 0 (149 400 117 Slab on Grade Area: 1,600 (N) 655 44 Average Ceiling Height: 10.0 Roof 1,918 0 Fenestration Average U -Factor: 0.48 TOTAL: 287 Average SHGC: 0.36 Fenestration/CFA Ratio: 18.0% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author P JIM Company Santiago Lopez-Ocampo 11/62013 Address P.O. Box 1018 Name City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building, e,vefope-sealing-Eeq ' e installer testing and certification and field verification by an approved HERS rate- OF LA QUANTA BUILDING & SAFETY Designer or Owner (per Business & Professions Code) DEPT. Company Coronel Enterprises APPROVED P P R O VE D Address 42760 Madio Street Name FOR CONSTRUCTION City/State/Zip Indio, Ca 92201 Phone 760.775.1234 Signed License # Dto DATE EnerqyPro 5.1 by EnemySoft User Number: 5732 RunCode: 2013-11-06716:30:32 ID: LQ080113 Pae of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Coronel Enterprises - Plan 1600 - East Orier Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Slab 972 0.730 None 0 180 New 4.4.7-A 1 Whole House Slab 628 0.730 None 0 180 New 4.4.7-A 1 Whole House Wall 598 0.068 R-13 5.0 None 0 90 New 4.3.1-A3 Whole House Wall 283 0.068 R-13 5.0 None 270 90 New 4.3.1-A3 Whole House Wall 558 0.068 R-13 5.0 None 180 90 New 4.3.1-A3 Whole House Wall 13 0.068 R-13 5.0 None 135 90 New 4.3.1-A3 Whole House Wall 321 0.068 R-13 5.0 None 90 90 New 4.3.1-A3 Whole House Wall 13 0.068 R-13 5.0 None 45 90 New 4.3.1-A3 Whole House Roof 1,918 0.025 R-38 0 0 New 4.2.1-A21 Whole House FENESTRATION SURFACE DETAILS ID Tvpe Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 20.0 0.590 NFRC 0.45 NFRC 0 New IWC 6200 Alum/Low-E Whole House 2 Window 6.0 0.590 NFRC 0.45 NFRC 0 New IWC 6200 Alum/Low-E Whole House 3 Window 6.0 0.590 NFRC 0.45 NFRC 0 New IWC 6200 Alum/Low-E Whole House 4 Window 20.0 0.590 NFRC 0.45 NFRC 270 New IWC 6200 Alum/Low-E Whole House 5 Window 10.0 0.440 NFRC 0.24 NFRC 270 New IWC 6200 Alum/Low-E Fix Whole House 6 Window 33.3 0.360 NFRC 0.35 NFRC 270 New Jeld-Wen, Steel Fr. Dr. Whole House 7 Wndow 10.0 0.440 NFRC 0.24 NFRC 270 New IWC 6200 Alum/Low-E Fix Whole House 8 Wndow 33.3 0.360 NFRC 0.35 NFRC 270 New Jeld-Wen, Steel Fr. Dr. Whole House 9 Window 10.0 0.440 NFRC 0.24 NFRC 270 New IWC 6200 Alum/Low-E Fix Whole House 10 Wndow 12.0 0.590 NFRC 0.45 NFRC 180 New IWC 6200 Alum/Low-E Whole House 11 Wndow 6.0 0.590 NFRC 0.45 NFRC 180 New IWC 6200 Alum/Low-E Whole House 12 Window 16.0 0.440 NFRC 0.24 NFRC 180 New IWC 6200 Alum/Low-E Fix Whole House 13 Wndow 8.0 0.440 NFRC 0.24 NFRC 180 New IWC 6200 Alum/Low-E Fix Whole House 14 Wndow 20.0 0.590 NFRC 0.45 NFRC 180 New IWC 6200 Alum/Low-E Whole House 15 Window 10.0 0.440 NFRC 0.24 NFRC 180 New IWC 6200 Alum/Low-E Fix Whole House 16 Window 8.0 0.590 NFRC 1 0.45 NFRC 1 1351 New IWC 6200 Alum/Low-E Whole House (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Ri ht Fin Len H t I LExt RExt Dist Len I H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 6.71 5.0 15.5 3.3 3.3 0.7 3.3 15.5 0 0.7 15.5 0 7 Bug Screen 0.76 2.0 5.0 15.5 0.8 3.3 0 7 3.3 15.5 0 0.7 15.51 0 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76I 11 Bug Screen 0.76 y " UE 12 Bug Screen 0.76 13 Bug Screen 0.76 F , 14 Bug Screen 0.76 15 JBug Screen 0.76 16 IBug, Screen 0.76 1 DATE By EnergyPro 5.1 by EnergySoft User Number. 5732 RunCode: 2013-11-06T16:30:32 ID: LQ080113 Page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Coronel Enterprises - Plan 1600 - East Orier Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 3.7 0.440 NFRC 0.24 NFRC 135 New IWC 6200 Alum/Low-E Fix Whole House 18 Window 16.0 0.590 NFRC 0.45 NFRC 90 New IWC 6200 Alum/Low-E Whole House 19 Window 7.3 0.440 NFRC 0.24 NFRC 90 New IWC 6200 Alum/Low-E Fix Whole House 20 Window 20.0 0.360 NFRC 0.35 NFRC 90 New Jeld-Wen, Steel Fr.Dr. Whole House 21 Window 8.0 0.590 NFRC 0.45 NFRC 45 New IWC 6200 Alum/Low-E Whole House 22 Window 3.7 0.440 NFRC 0.24 NFRC 45 New IWC 6200 Alum/Low-E Fix Whole House (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 6.7 3.0 15.5 2.0 2.8 0.5 0.0 0.0 0 0.5 13.5 0 21 Bug Screen 0.76 22 Bug Screen 0.76 y I IQUIN I f I�11r7 !A T r ASI I DATE E3y---- EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-11-06716:30:32 6 Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Coronel Enterprises - Plan 1600 - East Orierl Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC System Whole House 1,600 16,000 Totals 1,6001 01 0 0 HVAC SYSTEMS System Name Qty. Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R-Value Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 8.0 10 New 13 WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A O Smith Water Products 1 Small Gas All Pipes Ins 40,000 40 0.65 n/a n/a New MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length ft 0 .9 -0:3 '0 CIT`' OF UControl I S j'st�em am" & S me� tit �!Wter Thick. Q HP Plenum Outside Buried ❑ 1 APP_ IM-N ❑ j—a_0 ❑ ❑ I DATE -_ [3y I EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-11-06716:30:32 ID: LQ080113 Page 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name Coronel Enterprises - Plan 1600 - East Orientation Date 1 111612013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF-1 R Form. *§1 50a : Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50d : Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. §150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF-1R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion-air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §23-0)2. Pipe insulation for steam hydronic heating systems or hot water systems>1�5-psi-,meetsf�h�e rgquui\remen � of-StandaF s Table k X �,i I I fig e r���lIJJ� O .[„J, 1 50' 3A: Insulation is protected from damage, includingthat due to sunlight, moist re, a ui menu maf6Wna eel, an w §1500)3A: Insulation for chilled water piping and refrigerant suction lines includesla vapor�r6t _--dant orris en to ed tine y iri conditioned space. a 1 "i L 150(j)4: Solar water-heating systems and/or collectors are certified by the Solar IRatin a d Certiti d ib T(RIr ovati'GN DATE ---- � BY EnergyPro5.1 by EnergySoft User Number: 5732 RunCode: 2013-11-06T16.30:32 D'YQ08099 Pa a 100 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Coronel Enterprises - Plan 1600 - East Orientation 1 11/6/2013 §150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 1 50k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms areMi h-efficacy-arA-c GAG manual-on occupant sensor. I CITY t` I A 01 o t §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more�hUj20� aLo po�re,ger�ln_e�EPT, illuminated cabinet. I rC I Y ' APPROVED FOR CONSTRUCTION TF EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2013-11-06T16:30:32�1ID: LQ080113 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Corone/ Enterprises - Plan 1600 - East Orientation 11/6/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. 'MOF LA QUINTA BUILpiN SAFETY DEPT. 'PROVED QFC 0 S'RUC, ©ASE -- 6y EnergyPro 5.1 by EnergySoR User Number. 5732 RunCode: 2013-11-06T16:30:32 /D: LQ080113 Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Coronel Enterprises - Plan 1600 - East Orientation 11/6/2013 System Name Floor Area HVAC System 1,600 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation 1 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING CFM Sensible 998 20,507 0 1,184 0 0 0 0 1 1,184 1 22,8741 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 80,000 2,202 425 16,530 Total Output Btuh 80,000 Output Btuh/s ft 50.0 812 Cooling System 0 Output per System 48,500 0 0 0 Total Output Btuh 48,500 2,202 0 Total Output ons 4.0 812 Total Output Btuh/s ft 30.3 Total Output s ft/Ton 395.9 18,155 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 YorkCZB48.PS8CN100.1600cfm 36,593 4,548 80,000 Airflow cfm/s ft 1.00 Airflow cfmrron 395.9 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 36,593 4,548 Aug 3 PM 80,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 �F 68 OF 68 OF 105 T Q Outside Air 0 cfm Supply Fan Heating Coil 1,i5 �F 1,600 cfm w.,. g�afcx.=,.=,.,cw ROOM 111:1:111; £2eeee�.e fib OF 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112; 76 OF 76!a"276162°F 55/54° .,:::. ....:.... ::>::::<QUINT Outside Air _ Supply Fan LA j DUiLDING & SAFETY DEPT4 0 cfm CoolingCoil r 1,600 cfm A P O :>.... ;. 47 7 /o E — FOR MSTE 761 ;i2 OF 751 62 F r by EnefgyPro 5.1 by EnergySoft User Number. 5732 RunCode: 2013-11-06716:30:32 ID: LQ080113 Page 13 of 13