05-1570 (RC) Title 24
Project Designer: Randall Barnett 300 W. Cortez Road Palm Springs, Ca 92262 (760) 778-5394 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CON STRUCTMOIN DA Date: 8/24/05 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. I EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form LTG -4 Tailored LPD Summary and Worksheet Form LTG -5 Room Cavity Ratio Worksheet Form LTG -MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads Room Cooling Coil Loads i 1 2 3 12 13 14 15 17 18 19 20 22 EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME . Club Achilles- Building 3 This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE 8/24/05 PROJECT ADDRESS 79-450 Highway 111 La Quinta UA . I t Ul- FLANb -it I [UNtU t-LUUK Building Permit # PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Randall Barnett (760) 778-5394 DOCUMENTATION AUTHOR H & H Air Conditioning TELEPHONE (760) 340-3088 Checked by/Date Enforcement Agency Use ISTATEMENT OF COMPLIANCE I This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Build'tg using he performance compliance approach. DOCUMENTATION AUTKOR UA . I t Ul- FLANb -it I [UNtU t-LUUK KIM7 8,231 sg.Ft. 15 BUILDING TYPE NONRESIDENTIAL HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION E] ADDITION ❑ ALTERATION EXISTING + ADDITION ISTATEMENT OF COMPLIANCE I This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Build'tg using he performance compliance approach. DOCUMENTATION AUTKOR SiGNA DAT Tim Scott The Principal Designers hereby certify that the proposed building design represented in the construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. R F-] 1. 1 hereby affirm that I am eligible Under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. EL 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. , n R ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) Indicate location on plans of Note Block for Mandatory Measures Envelope Compliance Not In The Scope 01 Required Forms Tlyi— Suhmittal PRINCIPAL ENVELOPE -DESIGNER - NAME [SIGNATUR LIC -NONDATE ILIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms LTG -1 PRINCIPAL LIGHTING DESIGNER - NAME 1 SIGNATURE 'n LIC. NO. JDAT' IMECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures j Required ormsECH-1, MECH-2, MECH-3 ^� j PRINCIPAL MECHANICAL DESIGNER -NAME SIG RELIC. NO. DATE H & H Air Conditioning �Q ,(� A ¢ "s: Kun Initiation I Ime: U8/24/05 11:06:02 Run Code: 1124906762 lEnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 23 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 TE Club Achilles- Building 3 8/24/05 ANNUAL SOURCE ENERGY USE SUMMARY u sq -yr ENERGY COMPONENT Standard Design, Proposed Design , Compliance Margin( �sianaard Space.Heating Space Cooling Indoor Fans Heat Rejection _ Pumps & Misc. Domestic Hot Water, Lighting35.35 Receptacle ,Process '•., ... '>. TOTALS: 2.70 2.66 0.04 '' s r'i c v J r"ice lC� < .: ISM F 1411101°� rear: r° c '���� , 60.94 as.os 11.88&A 22.20 21.7s 044 0.00 0.00 0.00 0.00 000 000 5.58 539, 0.18 30.76 4.59 22.71 22.71 0.00 0.00 0.00 -- 0.00 - 149.47 132.34 17.13 s 0 �0 403 +sr'g ` ewlsan yr I GEN ERWM FORMATION Building Orientation (Northwest) 315 deg Conditioned Floor Area 8,231 sqn. Number of Stories 1 Unconditioned Floor Area. 0 sqn. ' Number of Systems, ,, 6 Conditioned Footprint Area 8,231 sgft. Number of Zones 1 Orientation Gross Area Glazing Area Glazing Ratio front Elevation` . (Northwest) 1,200 sqn. 556 sqn. 46.3% Left Elevation (Northeast) 690 sqn. 60 sgft. 8.7% Rear Elevation (Southeast) 1,200 sqn. 0 sqn. 0.0% Right Elevation (Southwest) 6901 sqn. 319 sqn. 46.20 Total 3,780 sqn. 1 935 sqn. Roof 8,231 sqn.sqn. 0.0% Standard Proposed Lighting. Power Density 1.200 wisgn. 1.045 wisgn. Prescriptive Env: ,Heat Loss 1,419 2,031 Prescriptive Env. Heat Gain 161,129 229,855 emar s: Run InitiationTime: un Code: 1124906762 �E�nergyPro 3.1 By EnergySon ... User Number: 5533 Job Number: Page:4 of 23 'PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Club Achilles- Building 3 DATE 8/24/05 System Name Zone Name Floor Area Occupancy Type (sqft.) Inst. LPD (W/sf)1 Port. Ctrl. LPD Credits (W/sf)1 (W/S02 lailored Proc. Loads (W/sf) (W/S03 HVAC -1 thru 6 Building 3 Comp Bldg Office 8,231 1.045 0.000 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special documentation The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification ino aocumemation suomittea. Plan I Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp 1 Kun Initiation I Ime: UWZ4/11.10 'I'I:Ub:UZ Kun uoae: "I1Z4UUbfbZ 1 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 23 1 [LIGHTING COMPLIANCE SUMMARY Part 1 of LTG -1 Club Achilles- Building 3 1 8/24/05 1 LAMPS I BALLASTS IF Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts er Lamp DESCRIPTION # tLdrnp T odnds Total Watts # Watts (1) 28w Compact Fluorescent Quad 2 Pin CFQ28W/GX32d-3 1 28 Magnetic Standard 1.0 13 34.0 442 175w High Bay Metal Halide MH175 1 175 Magnetic Standard 1.0 21 210.0 4,410 75w Dircctional Incandescent 75W 1 75 No Ballast 81 75.0 600 75w Pendant Incandescent 75W 1 75 No Ballast 575.0 375 75w Recessed Incandescent 75W 1 75 No Ballast 37 75.0 2,775 8,602 Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 8,602 �0 Efficacy and Control Requirement of§130(c) Portable Lighting (From LTG -1) Less Control Credit Watts (From LTG -3) Control Requirements ofg131(f) Adjusted Actual Watts 8,602 CONTROLLOCA (Room #) CONTROL LOCATIO (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) CONTROL CONTROL TYPE IDENTIFICATION (Occupant, Daylight, Dimming, etc.) SPACE CONTROLLED LUMINAIRES CONTROLLED I NOTE TO FIELD NOTE TO FIELD - or Building Uepartment Use Unly Run InitiationTime: 08124/05 2 Run Code: 1124906762 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 23 LIGHTING COMPLIANCE SUMMARY Part2 of LTG -1 Club Achilles- Building 3 1 8/24/05 1 a o a a OR ZONE ID (W/sgft) (SF) (B X C) TOTAL 0 0 F a n a a o 0 LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING #0F WATTS PER AREA TASK AREA (SF) WATTS ROOM # TOTAL AREA OR ZONE ID (SF) Designer needs to provide detailed documentation that the lighti level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTALI 0 BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1B) BUILDING TOTAL 8,231 0 Run InitiationTime: 5 2 Run Code: 1124906762 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Pagel of 23 CERTIFICATE OF COMPLIANCE Performance MECH-1 Club Achilles- Building 3 8/24/05 SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM (MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATIO R -VALUE CEILING/ROOF SPACE DHW Heater n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Electric Res 98% BRADFORD -WHITE LD - 120F3 -3 na Yes Yes n/a n/a n/a n/a n/a HVAC -1 thru 6 Programmable Switch Heating & Cooling Requir n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 823 cfm Heat Pump 7.20 HSPF Packaged DX 12.0 SEER / 10.2 EER Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: NoVENTILATION ? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? it t3alance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural Auto G: Gravity it W: Water N: Not Required EC: Economizer Control See Section 144(e)3 Enter Outdoor it CFM. Note: This shall be n less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPAC - ror tsu Run InitiationTime: 5 un Code: 1124906762 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 23 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME Club Achilles- Building 3 DATE $/24/05 Motor Location CFM Efficiency Tons PUMPS CFM 1 Motor Eff. Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. _ Pump Control TANICIIISUL. Energy Factor or Recovery Efficiency Standby Loss or Pilot System Name . System Type Distribution Type Qty Rated Input (Gals.) Vol. Ext. R -Val. BRADFORD -WHITE LD - 120R3 -3 Storage Elec. Standard 1 184,302 119 0.00 n/a Na 'AL SYSTEM 17=65 ' System Name System Type Qty. ATING Aux. Output kW Eff. __ C-OOLI�TG Output Sensible Efficiency Economizer Type CARRIER 50JX0605 Packaged DX 6 57,000 0.0 7.20 HSPF 60,000 42,00012.0 SEER / 10.2 EE No Economizer SUPPLY FAN I PFTIIRN PAW System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. CARRIER 50JXOfi05 Constant Volume Draw -Through 2,000 0.70 77.0% 100.0% none EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:9 of 23 1 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME Club Achilles- Building 3 DATE 8/24/05 ZONE TERMINAL MUM= Zone Name System Type Qty. Min. CFM Ratio Reheat Coil CFM BHP Motor Eff. Drive Eff. Type Output Type DeltaT Room Name Qty. CFM BHP Motor Eff. Drive Eff. Room Name Qty. CFM BHP Motor Eff. Drive Eff. Run InitiationTime: un Code: 1124906762 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 10 of 23 'MECHANICAL VENTILATION MECH-3 Club Achilles- Building 3 8/24/05 a ©© o a o© a o a o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 23 1 AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS. FER AIR ZONE/SYSTEM AREA (SF) CFM PER SF . CFM (B x C) NO. OF PEOPL OFM PER PERSON MIN. CFM (ExF) Building 3 8,231 0.15 1,235 1,235 823 412 HVAC -1 thru 6 Total 1,2351 8231 1 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 23 1 TAILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 Club Achilles- Building 3 1 8/24/05 FA-] © a a 1. Watts for Illuminance Categories A -D (from column G) > 0 watts 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) 0 watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) 01+ 1 0 + I 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3) 0 watts a FA-] © a a In a ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) Building A 0.63 0 0.20 0 PAGE TOTAL BUILDING TOTAL 8,231 �p SF WATTS IROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -5 Club Achilles- Building 3 1 8/24/05 Room Name Task/Activity Description Room Length (L) Room Width (W) Hoom Cavity Height (H) Room Cav.a io 5xHx(L+W) /(LxW) Room Name Task/Activity Description Room Area (A) Room Perimeter (P) Room Cavity Height (H) Room Cay. Ratio 2.5 x H x P /A LIGHTING MANDATORY MEASURES LTG -MM Club Achilles- Building 3 8/24/05 DESCRIPTION Designer Enforcement [XI § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. [XI § 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. L_J § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. [X1 § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. [y� _J § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with I a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. u § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 14 of 23 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM Club Achilles- Building 3 8/24/05 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies t () i §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. Cl§ 115(a) Fan type central furnaces shall not have a pilot light. U§ 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. U§ 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or l� § 122(e)1B An occupancy sensor to control the operating period of the system; or IF -1 122(e)1C A 4 -hour timer that can be manual) operated to control the operating §y p p g period of the --- ------ � system. i r'yl § 122(e)2 Each space conditioning system shall be installed with controls that temporarily u restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall j I be controlled by a time control device as described above. U § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. u § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. F] § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. I—- EnergyPro 3.1 By EnergySok User Number: 5533 Job Number: Page: 15 of 23 —� [MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM NAME Club Achilles- Building 3 8/24/05 Description Designer Enforcement Ventilation U§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ' § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. (XI § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible ll�� manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or ❑ § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or U remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or (� § 121(f)4 Another method approved by the Commission. Service Water Heating Systems - § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. LJ § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:16 of 23 -IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Club Achilles- Building 3 8/24/05 SYSTEM NAME FLOOR AREA HVAC -1 thru 6 8,231 Number of Systems 1 s Heating System Output per System 57,000 Total Output (Btuh) 342,000 Output (Btuh/sgft) 41.6 Cooling System Output per System 60,000 Total Output (Btuh) 360,000 Total Output (Tons) 30.0 Total Output (Btuh/sqft) 43.7 Total Output (sgftrron) 274.4 Air System CFM per System 2,000 Airflow (cfm) 12,000 Airflow (cfm/sqft) 1.46 Airflow (cfm/Ton) 400.0 Outside Air (%) 6.9 Outside Air (cfm/sqft) 0.10 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 13,850 199,793 29,342 9,661 139,236 60.3% R.H. ROOMS 0 74.0 / 64.5 OF 9,990 6,962 0 0 823 32,601 8,003 823 38,065 0 0 9,990 6,962 252,373 37,346 191,224 HVAC EQUIPMENT SELECTION CARRIER 50JX0605 225,686 98,093 224,925 Total Adjusted System Output . 225,s8s 98,093 22x,925 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am PICA I Irvb JTJ I CIVI r'JTk r1KUlVIt I KII.J (Airstream I emperatUres at I Ime oT rleating reaK) 26.0 OF 66.5 °F 84.1 °F 84.1 OF O Supply Air Ducts Outside Air • -w 823 cfm 83.5 °F Heating Coil Supply Fan 12000 cfm ROOMS 6 70.0 °F 9.5 OF Return Air Ducts me of L;oonna vea 12.0/77.9°F 77.3/65.7°F® 59.7/58.8°F 59.7/58.8°F -.* Su I Air Ducts Outside A 823 cfm 74.8/64.7 °F Cooling Coil O PP Y Supply Fan 60.4 / 59.0 OF 12000 cfm 60.3% R.H. ROOMS 74.0 / 64.5 OF �, Return Air Ducts Y I EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 17 of 23 IROOM LOAD SUMMARY PROJECT NAME Club Achilles- Building 3 DATE 8/24/05 SYSTEM NAME HVAC -1 thru 6 FLOOR AREA 8,231 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Building 3 w ing 1 13,850 199,793 29,342 13,850 199,793 29,342 9,661 139,236 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 18 of 23 ROOM HEATING PEAK LOADS Club Achilles- Building 3 8/24/05 Room Information uesign Vonaltlons Room Name Building 3 Time of Peak Jan 12 am Floor Area 8,231 Outdoor Dry Bulb Temperature 260F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 107,117 In I 1A0 x 1.064 x 8,231 x 10.00 x 0.50 / 6G1 x = 32,118 Schedule Air Sensible Area Ceiling Height ACR pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 173936]7,2 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 19 of 23 _1 8,231.0 x X X X X x x X X X X X X X X X X X X X X X X X X X X X X X X x X X X X X x X 0.1073 X x X x X x x X X X X X X X X X X x X X X X X X X X X x X X X X X X X X X X X 44.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 2,703.0 0.1717 44.0 142.0 0.1460 44.0 851.0 0.7200 44.0 84.0 0.8500 44.0 perimeter = 378.0 44.5 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 107,117 In I 1A0 x 1.064 x 8,231 x 10.00 x 0.50 / 6G1 x = 32,118 Schedule Air Sensible Area Ceiling Height ACR pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 173936]7,2 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 19 of 23 _1 DOOM COOLING PEAK LOADS Project Title Club Achilles- Building 3 Date 8/24/05 1ROOM INFORMATION DESIGN CONDITIONS Room Name Building 3 Time of Peak Jul 3 pm Floor Area 8,231 Outdoor Dry Bulb Temperature 112 Indoor Dry Bulb Temperature 74� Outdoor Wet Bulb Temperature 78 Conduction Area R-30 Roof(R.30) R-19 Wall Insulated Metal Door Insulated Metal Door Double Metal Tinted Default R-19 Wall R-19 Wall Double Metal Tinted Default Double Metal Tinted Default 8,231.0 488.0 42.0 100.0 120.0 1,200.0 371.0 495.0 200.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain LI -Value 0.1073 0.1717 0.1460 0.1460 0.7200 0.1717 0.1717 0.7200 0.7200 Orientation Area SGF SC (Northeast) 60.0 x x X x x x x x x X 42 x x X x x x x x x X 0.623 (Southwest) 99.0 189 0.623 (Southwest) 50.0 189 0.623 (Southwest) 42.0 189 0.623 (Southwest) 18.0 189 0.623 (Southwest) 50.0 189 0.623 (Southwest) 60.0 189 0.623 (Northwest) 99.0 50 0.623 (Northwest) 99.0 50 0.623 (Northwest) 50.0 50 0.623 DETD 1 64.3 = 38.2 = 42.0 = 42.0 = 27.0 = 38.7 = 51.6 = 27.0 = 27.0 = Page Total Weighting Factor x 1.400 = x 0.428 = X 0.428 = X 0.428 = x 0.428 = x 0.428 = x 0.428 = x 0.698 = x 0.698 = x 0.716 = Page Total Btu/hr 56,8271 3,201 257 613 2,334 _ 7,982 3,288 9,630 3,891 88,023 Btu/hr 2,2001 4,995 2,523 2,119 908 2,523 3,027 2,155 2,155 1,1171 23,722 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1 11.00 x 8,231 x 1.045 Watts/sgft x 3.413 Btuh/Watt x 0.998 = 29,311 Occupants 1.0d x 8,231 X 300 Btuh/occ. / 150 sgft/occ. x 1.00 = 16,462 Receptacle 1 00 x 8,231 x 0.000 Watts/sgft x 3.413 Btuh/Watt x 1.00 = 0 Process 01 x 8,231 x 0.000 Watts/sqft x 3.413 Btuh/Watt x 1.00 = 0 Infiltration: 1.00 x _ 1.064 x 8,231 x _10.00 x 0.50 / 50] x 38 = 27,7391 Schedule Air Sensible Area Ceiling Height ACFI pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 199,793 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 8,231 X 300 Btuh/OCC. / 150 Sgft/oCC. = 16,462 Receptacle 1.00 X 8,231 X 0.000 Watts/sq ft x 3.413 BtuhlWatt = p Process f 1.00 x 8,231 x 0.000 Watts/sgft x 3.413 Btuh/Watt = o Infiltration: I 1.00 x _ 4771 x 8,231 x _10.00 x 0.50 /s J x h�uOQ00394 = 12,880 LScle Air Lateneiling t Area CHeight ACFI o.�..•o.... NOTAL HOURLY LATENT HEAT GAIN FOR ROOM 29,342 ' EnergyPro 3.1 By EnergySoft User Number: 5533 Page:20 of 23 ROOM COOLING PEAK LOADS Title Club Achilles- Building 3 1 8/24/05 1 Room Name Floor Area Indoor Dry Bulb Temperature Conduction Double Metal Tinted Default Double Metal Tinted Default R-19 Wall Building 3 1 Time of Peak 8,231 Outdoor Dry Bulb Temperature 74'� Outdoor Wet Bulb Temperature Area 84.0 X 36.0 X 644.0 X X X X X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.8500 0.7200 0.1717 Orientation Area X X x x x x X X x x SGF x X X X x X x X X X SC (Northwest) 42.0 50 0.623 (Northwest) 18.0 50 0.623 (Northwest) 50.0 50 0.623 (Northwest) 99.0 50 0.623 (Northwest) 99.0 50 0.623 DETD 1 26.1 = 27.0 = 47.4 = Page Total Weighting Factor x 0.703 = X 0.681 = x 0.716 = x 0.698 = x 0.698 = x = X = X = X = x = Page Total Jul 3 pm 112 78 Btu/hr 1,867 700 5,238 7,8os Btu/hr 921 3821 1,117 2,1551 2,155 1 6,730 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights ghts 1.00 X 8,231 X 1.045 Watts/sgft X 3.413 Btuh[Watt x 0.998 = 29,311 Occupants 1.00 x 8,231 X 300 Btuhlocc. / 150 sgft/occ. x 1.00 = 16,462 receptacle 1.001 X 8,231 x 0.000 Watts/sqft x 3.413 BtuhfWatt x 1.00 = 0 rocess 1.00 x 8,231 x 0.000 Wattslsgft x 3.413 BtuhlWatt x 1.00 = 0 Infiltration: 1.IF"hedul00 x Air Sen 1.s6 e x Ar 8'231 X ening H0.. 0 X ACE01. I 50 / 60] X QT 38 = 27,739 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 199,793 -Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccupants 1.00 X 8,231 X 300 Btuhlocc. / 150 SgftloCC. = 16,462 j /Receptacle 1.00 X 1 8,2311 x 0.000 Wattslsgft x 1 3.413 Btuh[Watt = !Process 1.00 X 8,231 x 0.000 Watts/sqft x 3.413 BtuhfWatt Infiltration: L1.00 x _ 4 771 x 8,231 x _eig10.00 x 0.50116] x 0.00394 = 12 880 chedu a Air Coat nt Area Ceiling Hhf ACH /\w Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 29,342 EnergyPro 3.1 By EnergySoft User Number: 5533 Page:21 of 23 ROOM COOLING COIL LOADS Project Title � Club Achilles- Building 3 Date 8/24/05 ROOM INFORMATION DESIGN CONDITIONS Room Name Building 3 Time of Peak Jul 3 pm Floor Area 8,231 Outdoor Dry Bulb Temperature 112 `k Indoor Dry Bulb Temperature 74�: Outdoor Wet Bulb Temperature 78: Conduction R-30 Roof(R.30) R-19 Wall Insulated Metal Door Insulated Metal Door Double Metal Tinted Default R-19 Wall I R-19 Wall i -- Double Metal Tinted Default Double Metal Tinted Default I - Area 8,231.0 X 488.0 X 42.0 X 100.0 X 120.0 X 1,200.0 X 371.0 X 495.0 X 200.0 X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.1073 0.1717 0.1460 0.1460 0.7200 0.1717 0.1717 0.7200 0.7200 X X X X X x X x X DETD 1 = = = = = = = = = 64.3 38.2 42.0 42.0 27.0 38.7 51.6 27.0 27.0 Orientation Area SGF SC (Northeast) 60.0 x x X x X x x X X X 42 x x x x X X x X x X 0.623 (Southwest) 99.0 189 0.623 (Southwest) 50.0 189 0.623 (Southwest) 42.0 189 0.623 (Southwest) 18.0 189 0.623 (Southwest) 50.0 189 0.623 (Southwest) 60.0 189 0.623 (Northwest) 99.0 50 0.623 (Northwest) 99.0 50 0.623 (Northwest) 50.01 50 0.623 Page Total Weighting Factor X 1.400 = X 0.428 = x 0.428 = x 0.428 = x 0.428 = X 0.428 = x 0.428 = X 0.698 = x 0.698 = x 0.716 = Page Total Btu/hr 56,827 3,201 257 613 2,334 7,982 3,288 9,630 3,891 88,023 Btu/hr 2,200 _ 4,995 2,523 2,119 908 2,523 3,027 2,155 2,155 1,117 ,722 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor lights r 11.01) x 8,231 x 1.045 Watts/sgft x 3.413 Btuh[Watt x 0.998 = 29,311 Occupants 1.0- x 8,231 X 300 Btuh/OCc. I 150 sgftlocc. x 1.00 = 16,462 Receptacle 1.00 X 8,231 X 0.000 Wattsl5gft x 3.413 Btuh/Watt X 1.00 = 0 Process 01 0 x 8,231 x 0.000 Wattslsgft x 3.413 BtuhlWatt x 1.00 = 0 Infiltration: 1.00 x _ 1.064 x 8,231 x _10.00 x 0.50 16] x 38 = 27,739 �chedule Air Sensible Area Ceiling Height ACR &T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 199,793 Sched. Btulhr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 8,231 x 300 Btuh/occ. / 150 sgft/occ. = 16,462 Receptacle ( 1.00 X 8,231 x 0.000 Watts/sqft x 3.413 BtuhlWatt = 0 Lrocess I 1.00 X 8,231 X 0.000 Watts/sgft X 3.413 Btuh/V11att = 0 Infiltration: _ 1.00 XL _ 4,771 x 8231 x _10.00 x 0.50 / 6] x 0.00394 = 12,880, Schedule A'v Latent Area eiling Height ACH /\w Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 29,342 I EnergyPro 3.1 By EnergySoft User Number: 5533 Page: 22 of 23 -� ROOM COOLING COIL LOADS Project Title - Club Achilles- Building 3 Date 1 8/24/05 IROOM INFORMATION DESIGN CONDITIONS Room Name Building 3 Time of Peak Jul 3 pm Floor Area 8,231 Outdoor Dry Bulb Temperature 112 Indoor Dry Bulb Temperature 74C� Outdoor Wet Bulb Temperature 78 Conduction Double Metal Tinted Default Double Metal Tinted Default i - R -19 Wall L Area X X X X X X X X X U -Value X X X X X X X X X 84.0 0.8500 36.0 0.7200 644.0 0.1717 (Northwest) 18.0 50 0.623 (Northwest) 50.0 50 0.623 (Northwest) 99.0 50 0.623 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain (Window r (Window r (Window (Window Window I�I Orientation Area . x x x X x x x x x x SGF X X X x x x x x x x SC (Northwest) 42.0 50 0.623 (Northwest) 18.0 50 0.623 (Northwest) 50.0 50 0.623 (Northwest) 99.0 50 0.623 (Northwest) 99.0 50 0.623 DETD 1 26.1 = 27.0 = 47.4 = Page Total Weighting Factor x 0.703 = x 0.681 = x 0.716 = x 0.698 = x 0.698 = x = x x = x = x = Page Total Btu/hr 1,867 700 5,238 7,806 Btu/hr 921 382 1,117 2,155 2,155 6,730 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.0( x 8,231 x 1.045 Watts/sqft x 3.413 Btuh/Watt x 0.998 = 29,311 Occupants 1.0( x 8,231 X 300 Btuh/OCc. I 150 sgft/occ. X 1.00 = 16,462 Receptacle 1.00 x 8,231 x 0.000 Watts/Sgft x 3.413 Btuh/Watt x 1.00 = 0 Process IF" 1.0 x 8,231 X 0.000 Watts/sgft X 3.413 Btuh/Watt X 1.00 = 0 " Infiltration: 1_00 x _ 1.064 X 8,231 X _10.00 x 0.50 / 60 x 38 =27,739 hedule Air Sensible Area Ceiling Height ACH- JJJ pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 199,793 Sched. Btu/hr Latent Gain Frac. Area Heat Gain O cc upants 1.00 X 8,231 x 300 Btuh/Occ. I 150 sgft/OCc. = 16,462 Receptacle 1.00 X 8,231 X 0.000 Watts/sqft x 3.413 Btuh/Watt = do Process 1.00 x 8,231 x 0f.00�0 Watts/sqft x 3.413 Btuh/Watt = Infiltration: [[S�-ct,�UeMduopoe X _ 4,771 X 8231 X I 10_00 x 0.50 / s0 X 0.00394 = 12,880 Air Latent Area eding Heigh ACEI Z�,yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2x,342 EnergyPro 3.1 By EnergySoft User Number: 5533 Page:23 of 23