Loading...
0306-070 (RPL) Title 24TITLE 24 REPORT Title 24 Report for: Larry Shields Avenida Bermudas - Garage Left La Quinta, CA Project Designer H CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA rE Report Prepared By: Joan D. Hacker Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 Job Number: Date: 6/4/02 4 Dy By The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. User Number. 2655 I I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 6 7 11 12 EnergyPro 3.1 By EnergySoft Job Number. User Number: 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Larry Shields 6/4/02 Project Title Date Avenida Bermudas - Garage Left La Quinta Project Address Building Permit # I nsu-Form Inc. (760) 324-0216 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,691 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1,691 f? Building Type: (check one or more) X❑ Single ,Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg_ Number of Dwelling Units: 1.00 Number of Stories: 1 Component TvDe Slab On Grade Slab On Grade R-13 Wall w/1" EPS Solid Wood Door R-38 Roof (R.38.2x14.16) FENESTRATION Floor Construction Type: ® Slab Floor ❑ Raised Floor Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) n/a 0.756 Exposed Slab MR -0.0 Perimeter Insulation n/a 0.756 Covered Slab MR -0.0 Perimeter Insulation Wood 0.059 Exterior Wall None 0.387 Exterior Door Wood 0.028 Exterior Roof Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (East) 40.0 0.55 0.65 Bug Screen X❑ ❑ ❑ X❑ Front (East) 34.7 0.57 0.67 Buq Screen X❑ ❑ ❑ O Right (North) 2.7 0.57 0.67 Bug Screen X❑ ❑ ❑ X❑ Right (North) 40.0 0.60 0.65 Bug Screen ❑x ❑ ❑ Q Rear (West) 80.0 0.55 0.65 Bug ScreenX❑ ❑ ❑ x❑ Rear (West) 20.0 0.72 0.73 Buq ScreenX❑ ❑ ❑ x❑ Rear (West) 18.0 0.57 0.67 Bug ScreenX❑ ❑ a Left (South) 30.0 0.60 0.65 Bug Screen x❑ ,❑ ❑ ❑ x❑ ❑ ❑ ❑ ❑ 1:1 1:1 El Q ❑❑ ❑ ❑ ❑ ❑ Run Initiation Time: 06/04/02 13:40:49 Run Code 023194449 Ener ro 3.1 By Ener oft User Number: 2655 Job Number: Page: 3 of 12 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Larry Shields 6/4/02 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.). (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments (:antral Ftimare 80% AFUE Ducts in Attic 4.2 Setback Living Zone Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethack Living 7nne WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value RHEEM 44V50 Small Gas R cir /Tim .+T .mo 1 40 ()00 50 0.63 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT' This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Joan D. Hacker Title/Firm: Address: Telephone: Lic. #: (signature) Enforcement Agency Name: Title/Firm: _ Address: Telephone_ (date) Title/Firm: Insu-For, Inc. Address: 68255 Corta Road Cathedral City, CA 92234 Telephone: (7601324-0216 (sign re) (date) (signature/stamp) (date) Run Initiation Time: 06/04/02 13:40:49 Run Code: 1023194449 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:4 of 12 Certificate of Compliance: Residential (Addendum) CF -1 R Larry Shields 6/4/02 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the Items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3ased on the adequacy of the special justification and documentation submitted. I Plan Field The HVAC System "Living Zone" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 590 sgft Exposed Slab Floor, 3.50" thick at Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1101 sgft Covered Slab Floor, 3.50" thick at Living HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field Run Initiation Time: 06/04/02 13:40:49 Run Code: 1023194449 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:5 of 12 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures ❑ '§ 150(.): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. ❑.§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in framed floors. ❑ § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. ❑ §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ❑ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control: 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑ §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ §150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemaltextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. ❑ '§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. ❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. ❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:6 of 12 Computer Method Summary (Part 1 of 3) C -2R 6/4/02 Proje t Title Date Avenida Rerrriudas - raraae Left La Qij4nta Project Address Building Permit # Inch -Form Inr (760) 324-0216 plan Check/Date Documentation Author Telephone Qamputer Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.03 0.75 0.29 Space Cooling 32.68 35.80 -3.12 Domestic Hot Water 14.53 11.66 2.87 Totals 48.24. 48.21 0.04 BUILDING COMPLIES GENERAL INFORMATION Conditioned Floor Area: 1,691 Floor Construction Type: X❑ Slab Floor Building Type: Single Fam Detached ❑ Raised Floor Building Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 16,910 Number of Stories: 1 Slab Floor Area: 1,691 BUILDING ZONE INFORMATION Zone Name Floor Area Volume # of Units Thermostat Vent Zone Type Type Hgt. Area C:nnrlitinnPd RPthnnk n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C -2R Larry Shields 6/4/02 Project Title Date FENESTRATION SURFACES Run Initiation Time: 06/04/02 13:40:49 Run Code: 1023194449 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 12 U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J-- Window Front (Fast) an_a n 550_ OB5 gn _9f1 DniihlP NonMtl Clear nafault Living 7nne 2 Window Front (East) 8.0 0.570 0.67 90 90 Double NonMti Clear Default Livinq Zone L Window Front (East) 26.7 0.570 0.67 90 90 Double NonMtl Clear Default Living Zone 4 Window Right (North) 2.7 0.570 0.67 0 90 Double NonMtl Clear Default Living Zone 5 Window Right (North) 40.0 0.600 0.65 0 90 Double NonMtl Clear Default Living Zone 6 Window Rear (West) 80.0 0.550 0.65 270 90 Double NonMtl Clear Default Living Zone L Window Rear (West) 20.0 0.720 0.73 270 90 Double Mtl Uncoated Default Living Zone 8 Window Rear (West) 18.0 0.570 0:67 270 90 Double NonMtl Clear Default Living Zone 5 Window Left (South) 0.600 0.65 180 90 Double NonMtl Clear Default Living Zone _30.0 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 6.8 6.0 8.0 0.1 8.0 8.0 2 Bug Screen 0.76 1.5 6.0 8.0 0.1 8.0 8.0 3 Bug Screen 0.76 6.8 2.0 8.0 0.1 8.0 8.0 4 Bug Screen 0.76 1.2 1.2 2.0 0.1 2.0 _ 2.0 5 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.8 _ 6.0 3.0 0. 3.0 3.0 7 Bug Screen 0.76 4.0 5.0 3.0 0.1 3.0 3.0 8 Bug Screen 0.76 1.5 6.0 3.0 0.1 3.0 3.0 9 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 _ Run Initiation Time: 06/04/02 13:40:49 Run Code: 1023194449 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 12 Computer Method Summary (Part 3 of 3) C -2R Larry Shields 6/4/02 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, HeayMeight 590 3.50 98 0.9A n/a —0 Living Zone / Slah on Grade Concrete. Heavyweight 1.101 3_50 28 0.98 n/a 2 Living Zone / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 100_76 0.0 _ 0 Living one Slab perimeter in0=76 0.0 _ 0 Living Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFXducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Living Zone Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Living Zone WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext: RHEEM 44V50 Small Gas Recirc1T4me+Temp 1_ 40.000 50 0.63 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Larry Shields 6/4/02 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the Items specified In this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement acencv determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted, Plan I Field The HVAC System "Living Zone" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 590 sqft Exposed Slab Floor, 3.50" thick at Living HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1101 sqft Covered Slab Floor, 3.50" thick at Living HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS JIVYIu CI. I IIC rIGRJ I41C1 IIIIJOL YVbUl I IW11\ it IC IICIY YC111144IIU11 4IIY YI4HIW*lll IC,\Illa V1 L11COU IIIC4,l YICD Vila IUF 111 Nr-tim I Plan I Field EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:10 of 12 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Larry Shields 6/4/02 SYSTEM NAME FLOOR AREA Living Zone 1,691 26.0 of 69.4 of Outside Air 0 cfm Supply Fan 2055 cfm 69.4 of 11.0 / 77.4 of 310 Outside Air o cfm 78.7/65.6 of 69.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,734 32,872 4,032 622 26,156 0 1,644 1,308 0 0 0 0 0 0 0 0 0 1,644 1,308 36 160 4 032 28 77 BDP CO. 563AN060-A 42,234 10,041 89,000 Total Adjusted System Output42,234 10,041 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 109.8 of Heating Coil �% Return Air Ducts "I METRICS (Airstream T 7R7/Rr,ROF 7R7/r,--iROF = r,qr,/r,RAOF Supply Fan Cooling Coil 2055 cfm Supply Air Ducts 109.2 of ROOMS 70.0 of Supply Air Ducts 60.3 / 58.7 of 51.1% R.H. ROOMS 78.0 / 65.3 of Return Air Ducts I I EnergyPro 3.1 By EnergySoft . User Number. 2655 Job Number: Page: 11 of 12 1 ROOM LOAD SUMMARY PROJECT NAME Larry Shields DATE 6/4/02 SYSTEM NAME Living Zone FLOOR AREA 1,691 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Zone Living 1 1,734 32,872 4,032 1,734 32,872 4,032 622 26,156 PAGE TOTAL 1 1,734 32,872 4,032 622 26,156 TOTAL 1 1,734 32,872 4,032 622 26,156 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Pege:12 of 12