003457 (RPL) Title 24R CEWED
JAN 2 0 1'9407
LA UINTA
COMMUCTY 01: VITY DrVELOOPME T DEPT
CARLOS EL I AS, CIVIL ENGINEER, CATHEDRAL CITY
/is/87
LATITUDE 33.8 WINTER TEMP. 31 DEG. SUMMER: TEMP. 11C-) DEG
I �5
/� If39
OWNER-- -------------------------------
/� '�99 .L
JOB SITE LOCATION__ Of _B �oG�C ;NO (Im 1 _
-f ----r-----------�----
REF.CAL.ENER:GY CONSERVATION DESIGN MANUAL, FORM , HEATING LOSSES
MANUAL J FOR: COOLING LOSSES
AREA BLDG 136'D SO. FT.
PERIMETER: 0 SO. FT.
INSULATION R VALUES ...SLAB o ...CEILING 38 ...WALL 11 ...
AREA NORTH WINDOWS 50 SQ.FT. PERCENT OF AREA 3.6523
AREA EAST WINDOWS 24 SQ.FT. PERCENT OF AREA 1.7531
AREA SOUTH WINDOWS 72.5 5 SQ.FT. PERCENT OF AREA 5.29584
AREA WEST WINDOWS 52 SQ.FT. PERCENT OF AREA 3.79839
AREA SKYLIGHTS o Sty? . FT . PERCENT OF AREA V
TOTAL WINDOW AREA 198.5 SQ.FT. PERCENT OF AREA 14.4996
THE U VALUE OF THE -WINDOWS IS .65 (.65= DUAL PANE, 1.1= SINGLE PANE)
THIS BLDG USES DRAPES & FLAT SHADING DEVICES* ON.WINDOWS(S.C.=.41)
(* mini -blinds, rolIar shades, venetian blinds or vertic=al blinds)
THE TOTAL S.C. OF THE WINDOWS IS o.263
SOUTH OVERHANG LENGTH 22
INTERIOR: THERMAL MASS AREA = X88 SO FT
ATTIC AREA = 948 -SO FT
INFILTRATION (STD 0.018, MED 0.0149 TIGHT 0.012) - . o14
HEATING LOSSES
FOOTING LOSSES... 9609.6 BTU
CEILING LOSSES... 1351.67 BTU
WINDOW LOSSES... 5031.97 BTU
WALL LOSSES.... 4871.88 BTU
INFILTRATION LOSSES... 5979.79 BTU
TOTAL HEAT LOSSES BTU/HR:... 26844.9
GAS FUR:NANCE SIZE 4� X536.3 BTU OF' 45,(--)(-)(-) BTU
COOLING LOSSES
FOOTING LOSSES... 9F151E. RTl
WINDOW LUSSES... S063.17 BTU
W8",. IA LOSSES..., 4996.8 bTU
&FILTRATION LOSSES... 6133.12 BTU
NO. OF PEOPLE... 5 COOLIN6 LOSSES... 2000
KITCHEN... 1500 BTU
DUCT LOSSES INCLUDED IN TOTAL
TOTAL COOLING LOSSES 34935.4 BTU
COMPLIANCE CHECK LIST PER DESIGN DATA
SLAB ON GROUND, -4 POINTS
WALL INSULATION, -6 POINTS
CEILING INSULATION' 0 POINTS
ATTIC' 3 POINTS
NORTH WINDOWS GLAZING 72 POINTS
EAST WINDOWS GLAZING 2 POINTS
SOUTH WINDOWS GLAZING -2 POINTS
WEST WINDOWS GLAZING - -2 POINTS
SKYLIGHT GLAZING ` 0 POINTS
EAST
SHADING COEFFICIENT
-1
POINTS
SOUTH
SHADING COEFFICIENT
-1
PU1i\il'S
WEST
SHADING COEFFICIENT
-2
POINTS
NORTH
SHADING COEFFICIENT
3
POINTS
SKYLIGHT
SHADING COEFF- IENT
0
POINTS
INFILTRATION -1 POINTS
THERMAL MASS 288 SQ.FT. 8 POINTS
SOUTH OVERHANG 0 POINTS
GAS FURNANCE 71 SE AND REFRIGERATION COOLING
THE EER OF THE COOLING SYSTEM IS 10
COOLING
15 POINTS
THE ALLOWABLE POINTS PER AB 163 IS -4 FOR THIS AREA 15
THE TOTAL POINTS ARE 10
THE FOLLOWING MANDITORY FEATURES/DEVICES ARE REQUIRED PERCAC TITLE 24
^
INSULATION AS SPECIFIED; PER MANUFACTURES LABLE
INFILTRATION CONTROL. DOORS, WINDOWS FULLY WEATHERSTRIPPED
OPENINGS CAULKED AND SEALED AROUND JOINTS IN WINDOW AND WALL SOLE PLATES AND
ELECTRIC OUTLET GASKETS ON ALL EXTERIOR WALLS
MANUFACTURED DOORS SHALL MEET APPLICABLE STANDARDS
BACK DRAFT DAMPERS ON EXHAUST FAN
FIREPLACES MUST HAVE TIGHT FITTING, CLOSEABLE DOORS COVERING FIREBOX
PROVIDE COMBUSTION AIR INTAKE DUCTS (6 SQ. IN.) WITH TIGHT FITTING DAMPER
DUCTS,
(6
BUILT PER CHAPTER 10 U.M.C.
GAS FURNANCE SIZED TO 1.3 DESIGN LOGS + 10 BTUH PER SQ. FT. OR 45,000 BTU
SETBACK THERMOSTATS SHALL HAVE AUTOMATIC SETBACK CAPABILITY /2 PERIODS PER 24 HR
WATER HEATER TO HAVE R-12 INSULATION WRAPPING, AND R-3 ON FIRST 5' OF PIPE
NAT. GAS STOVES SHALLL NOT HAVE CONT. BURNING PILOTS
LIGHT IN KITCHEN AND BATH TO BE FLOURECENT, EXCEPT BATH MIRROR KIT SINK, TABLE
.^'