Loading...
15234 (SFD) Title 24REVISED Title 24 Energy Conservation Standards Residential Compliance Report MR. & MRS. PETE HENDREN RESIDENCE 79-140 BIG HORN TRAIL, PAINTED COVE, LA QUINTA Prepared by Madlin's Enterprises Title 24 Energy Calculations & Consulting Post Office Box 1443 • Palm Springs, California 92263 Job Number: 158908 - Date: June 29, 1995 MADLIN'S ENTERPRISES Title 24 Energy Calculations & Consulting Post Office Box 1443 • Palm Springs, California 92263 Telephone 619-323.3644 REVISED TITLE 24 ENERGY CONSERVATION STANDARDS COMPLIANCE REPORT This proposed residential project has been reviewed for compliance with the 1992 State of California Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design described in this compliance portfolio' is in conformance with the standards as outlined in the attached compliance forms and documentation. Job Number: 15890B Date: 06/ 29/ 95 Prepared For: HENDREN CONSTRUCTION Owner's Name: MR & MRS. PETE HENDREN Project Name: HENDREN RESIDENCE Project Location: 79-140 BIG HORN TRAIL, PAINTED COVE, LA QUINTA Method Of Compliance: MICROPAS V 4.0 COMPUTER PROGRAM Orientation Of Entry: SOUTH Certified Energy Analyst Catherine M. Madlin NR 92-90-544 r r R 92-90-144 rCABEC California Association of Building Energy Consultants The Mic ropas version 4.0 computer program has been used to perform the calculations summarized in this compliance report. This program has approval and Is authorized by the California Energy Commission for use with residential building energy efficiency standards for residential occupancies. MADLINS ENTERPRISES Title 24 Energy Calculations & Consulting Post Office Box 1443 e Palm Springs, California 92263 Telephone 619-323-3644 REVISED FINAL SUMMARY OF REQUIREMENTS - JOB # 15890B MR. & MRS. PETE HENDREN RESIDENCE 79-140 BIG HORN TRAIL, PAINTED COVE, LA QUINTA ... . .................... ...... ..... ........... .. ...... ............ ...<:<:<:::<::::::::<:>.. ..........>:'><'>>`>'>>;>:.......... .. . . .......................... ....... .................. ........ ........... :0 BU D NG:' DES C RI P -7-10W F.: L I COM . ......... ....... ..... .... .... ........ NIM L C ...... ... E.41EQVIREIVIE .............. Job No. File No. 1589OB17 Total Conditioned Square Footage 3330 Total Glass Area 1059 Sq. Ft. Total Glazing % (Floor to Glass Area Ratio) 31.8% Insulation: Roof / Ceiling R38 Insulation: Walls R21 Insulation: Floor - Raised NA Insulation: Floor - Slab on Grade Not Required Insulation: H.V.A,C. Ducts/ Location R4.2 Attic Glazing U Value / Type: Operable (Milgard or Equal) .75, Dual Pane, Alum. Frame, Argon Gas Glazing U -Value / Type: Fixed (Milgard or Equal) .60 Dual Pane, Argon Gas Glazing U -Value / Type: Patio (Milgard or Equal) .77 Dual Pane, Argon Gas Glazing U -Value / Type: Glass Block Large Openings '= .72 / Small Openings = .57 Glazing U -Value / Type: Skylights 0.80 Glazing U -Value / Type: Greenhouse None Glazing: Shade Coefficient (TINT) 0.75 Tinted Bronze / .36 Skylights Glazing: Exterior Shading Overhangs Glazing: Interior Shading .40 Roller Shades - Most Windows Thermal Mass Square Footage 980 Sq. Ft. Thermal Mass % (Floor Area to Mass Area Ratio) 29% H.V.A.C. System Type Gas Heating / Electric Cooling Heating System Efficiency 80% AFUE Cooling System Efficiency 12.0 SEER Domestic Hot Water Heater (2) 50 Gal. Gas Energy Factor .62 R12 Blanket Yes Hot water system on Recirculating Pump Yes - Time & Temperature Control MADLIN'S ENTERPRISES Title 24 Calculations and Consulting Job Number: 15890B Date: June 29, 1995 Prepared For: MR. & MRS. PETE HENDREN Prepared By: C.Madlin Project Name: HENDREN RESIDENCE Project Location: 79-140 BIG HORN TRAIL, PAINTED COVE NOTE TO PLAN CHECKER Attached you will find a new set of Title 24 compliance documentation for the project listed above. Please disregard all previous calculations and requirements. We would like to bring to your attention the following items: 1. This Title 24 Compliance Report is in response to a plan check correction. 2. The following changes have been made in the attached calculations. a. Three (3) 2x2 skylights have been added. Due to the extent and effect of this change new computer simulations runs were required and new reports have been compiled. No values or inputs have been changed except the addition of the skylight areas and values. Please feel free to contact our office if you have*any questions about the attached calculations or our methodology. IW CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 t dd Projec A Jess........ 79-140 BIG HORN TRAIL PAINTED COVE, LA QUINTA Documentation Author... CATHERINE M. MADLIN Company ................ Madlin's Enterprises Telephone .............. 619-323-3644 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone.......... 15 Field ec Dat& MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -FORM CF -1R User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED GENERAL INFORMATION Conditioned Floor Area..... 3330 sf Building Type .............. Single Family Detached, Construction Type ......... New Building Front Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 1 Number of Stories.. ...... 1 e.... Slab On Grade (Package D) Floor Construction Typ Component Type BUILDING SHELL INSULATION Insulation Assembly R -value U -Value Location/Comments Wall R-21 0.059 Door R-0 0.330 _Roof R-38 0.025 SlabEdge R-0 0.900 SlabEdge R-0 0.720 SlabEdge R-0 0.550 SlabEdge R-0 0.500 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior, hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Left (W) 29.0 0.750 2 Roller.Lt 50% bug scr Yes Metal Window Front S 40.0 0.750 2 Roller.Lt 50% bug sdr Yes Metal window Back �N� 30.0 0.750 2 Roller.Lt 50% bug scr Yes Metal Door Left (W) 64.0 0.770 2 Roller.Lt 50% bug scr Yes Metal Window Front (S) 16.0 0.570 2 Default.dra None *Yes None Door Back (N) 280.0 0.770 2 Roller.Lt 50% bug scr Yes Metal Window Back (N) 120.0 0.600 2 Roller.Lt None Yes Metal Window Left (W 50.0 0.600 2 Roller.Lt None Yes Metal Window Right (E� 84.0 0.600 2 Roller.Lt None Yes Metal Door Front (S) 64.0 0.770 2 Roller.Lt 50% bug scr Yes Metal Window Front (S) 202.0 0.600 2 Roller.Lt None Yes Metal Window Left (W) 16.0 0.570 2 Default.dra None Yes None Door Right (E) 64.0 0.770 2 Roller.Lt 50% bug scr Yes Metal Skylight Horz 12.0 0.800 .2 Medium wht None None Metal CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -FORM CF -1R User#k-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade Yes 980 3.5 SEE SCHEDULE S1abOnGrade No 2350 3.5 Insulation Tank Type Heater Type Distribution Type HVAC SYSTEMS Factor (gal) Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Furnace 0.800 AFUE Attic R-4.2 Setback ACSplit 12.00 SEER Attic R-4.2 Setback WATER HEATING SYSTEMS SPECIAL FEATURES/REMARKS The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his option) install better materials without additional compliance calculations. The installing hvac contractor shall provide the required CF -6R with the installed hvac equipment model numbers. A Night setback thermostat is required to be installed with the HVAC system. The installing plumber shall provide the required CF -6R listing the -water heater model number(s) and the certified plumbing fixtures. Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value DHW1 Storage Gas Recirc/TimeTemp 1 0.62 EF 50 R-12 DHW2 Storage Gas Recirc/TimeTemp 1 0.62 EF 50 R-12 SPECIAL FEATURES/REMARKS The values and materials used in this compliance portfolio are the minimum required to show compliance with Title 24 Energy Conservation Standards. The owner may (at his option) install better materials without additional compliance calculations. The installing hvac contractor shall provide the required CF -6R with the installed hvac equipment model numbers. A Night setback thermostat is required to be installed with the HVAC system. The installing plumber shall provide the required CF -6R listing the -water heater model number(s) and the certified plumbing fixtures. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -FORM CF -1R User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. . DESIGNER or OWNER Name.... M/M PETE HENDREN Company. Address.79-140 BIG HORN TRAIL LA QUINTA, CA 92253 Phone... License.' Signed.. ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... t*4 Signed.. (date) DOCUMENTATION AUTHOR Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, Ca 92263 Phone... 619-323-3644 Signed.. A16 (date), Certified Energy Analyst Catherine M. Madlin NR 92-90-544 ,r- ,r- R 92-90-144 CABECL______. California Association of Building Energy Consultants Mandatory Features & Devices Checklist: Residential MF -113 DOCUMENTATION AUTHOR: MADLIN'S ENTERPRISES CERTIFIED ENERGY ANALYST: CATHERINE M. MADLIN TELEPHONE NUMBER: 619-324-1731 For Enforcement Agency Use Only Building Permit Number NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES BLDG.DEPT. • § 150(a): Minimum R-19 ceiling insulation ............................................ • § 150(b): Loose fill insulation manufacturer's labeled R -Value .............................. • § 150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass) ......... • § 150(d): Minimum raised floor insulation: R-13 framed floors; R-8 concrete raised floors ........ • § 150(1): Slab edge insulation - meets maximum water absorption rate & water vapor transmission rate • § 118:.In.aulation.speCified or installed meets C.E.C. quality standards. Indicate type and form. ... . • § 166-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls ............. a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage b. Manufactured fenestration products have label with certified U -value, and infiltration certification c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed • § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only ....................... • g 150(0: Special infiltration barrier installed to comply with §151 meets Commission quality standards ,• § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs ................. 1. Masonry and factory -built fireplaces have: a. Closeable meatal or glass door. b. Outside air intake with damper and control. c. Flue damper and control. 2. No continuous burning gas pilots allowed. SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES • § 110-13: HVAC equipment, water heater, showerhead and faucets certified by the commission ... • § 150(i): Setback thermostat on all applicable heating systems ............................ • § 1500): Pipe and Tank Insulation ................................................. 1. Indirect hot water tanks have insulation blanket R-12 or greater or combined int./ext. R-16 or greater. 2. First 5 feet of pipes closest to water heater tank, non recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55'F insulated. 5. Piping insulated between heating source and indirect hot water tank. • § 150(m): Ducts and Fans ....................................................... 1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulajed to a minimum installed value of R-4.2 or ducts enclosed entirely with conditioned space. 2. Exhaust fan system have backdraft or automatic dampers 3. Gravity ventilating systems shall have automatic or readily accessible, manually operated dampers. • § 114: Pool and Spa Heating- Systems and Equipment .................................. 1. System shall be 78% thermal efficiency, have an on-off switch, & weatherproof operating instructions. No electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and circulation pump time switch. • § 115: Gas-fired fau, pool heater, spa heater or household cooking appliance have no continuously burning pilot light. (Exception: Non -electrical cooking appliance with pilot < 150 btu/ hr.) ........ LIGHTING MEASURES • § 150(k): 40 lumens / watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved ............................... COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 t dd Projec A ress........ 79-140 BIG HORN TRAIL PAINTED COVE, LA QUINTA Documentation•Author... CATHERINE M. MADLIN Company ................ Madlin's Enterprises Telephone .............. 619-323-3644 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Field ec Date MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -FORM C -2R User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED MICROPAS4 ENERGY USE SUMMARY' Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 3.53 3.97 -0.44 Space Cooling.......... 30.36 30.16 0.20 Water Heating.......... 7.85 7.54 0.31 Total 41.74 41.67 0.07 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area.. .......... Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... 3330 sf Single Family Detached New Front Facing 180 deg (S) 1 1 FullYear Slab On Grade (Package D) 1 29970 cf 3330 sf 3330 sf 3330 sf 32.2 % of FA 9 ft BUILDING ZONE INFORMATION Floor # of Area Volume Dwell Cond- Thermostat Zone Type (sf) (cf) Units itioned Type Vent Special Height Vent Area (ft) (sf) HOUSE Residence 3330 29970 1.00 Yes Setback 2.0 n/a COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -FORM C -2R - User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED JI PERIMETER LOSSES Length OPAQUE SURFACES Area U- Insul Act Factor Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 9 SlabEdge 82 1 Wall 333 0.059 R-21 180 90 Yes W.21.2X6.16 2 Wall 637 0.059 R-21 270 90 Yes W.21.2X6.16 3 Wall 503 0.059 R-21 0 90 Yes W.21.2X6.16 4 Wall 569 0.059 R-21 90 90 Yes W.21.2X6.16 5 Wall 320 0.059 R-21 180 90 No W.21.2X6.16 6 Door 40 0.330 R-0 180 90 Yes None 7 Door 24 0.330 R-0 0 90 Yes None 8 Roof 3330 0.025 R-38 180 18 Yes R.38.2X6.16 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE 9 SlabEdge 82 0.900 R-0 No 10 SlabEdge 233 0.720 R-0 No 11 SlabEdge 27 0.550 R-0 No 12 SlabEdge 11 0.500 R-0 No FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 9.0 2 Metal Slider 0.750 270 90 0.75 0.40 Roller.Lt 2 Window 15.0 2 Metal Slider 0.750 180 90 0.75 0.40 Roller.Lt 3 Window 20.0 2 Metal Slider 0.750 270 90 0.75 0.40 Roller.Lt 4 Window 15.0 2 Metal Slider 0.750 0 90 0.75 0.40 Roller.Lt 5 Door 64.0 2 Metal Slider 0.770 270 90 0.75 0.4p Roller.Lt 6 Window 16.0 2 None Slider 0.570 180 90 0.88 0.78 Default.dra 7 Door 64.0 2 Metal Slider 0.770 0 90 0.75 0.40 Roller.Lt 8 Door 64.0 2 Metal Slider 0.770 0 90 0.75 0.40 Roller.Lt 9 Window 10.0 2 Metal Slider 0.600 0 90 0.75 0.40 Roller.Lt 10 Window 40.0 2 Metal Slider 0.600 0 90 0.75 0.40 Roller.Lt 11 Window 10.0 2 Metal Slider 0.600 270 90 0.75 0.40 Roller.Lt 12 Window 40.0 2 Metal Slider 0.600 270 90 0.75 0.40 Roller.Lt 13 Window 10.0 2 Metal Slider 0.600 0 90 0.75 0.40 Roller.Lt 14 Window 40.0 2 Metal Slider 0.600 0 90 0.75 0.40 Roller.Lt 15 Window 20.0 2 Metal Slider 0.600 0 90 0.75 0.40 Roller.Lt 16 Door 88.0 2 Metal Slider 0.770 0 90 0.75 0.40 Roller.Lt 17 Window 15.0 2 Metal Slider 0.750 0 90 0.75 0.40 Roller.Lt 18 Door 64.0 2 Metal Slider 0.770 0 90 0.75 0.40 Roller.Lt 19 Window 52.0 2 Metal Slider 0.600 90 90 0.75 0.40 Roller.Lt 20 Window 32.0 2 Metal Slider 0.600 90 90 0.75 0.40 Roller.Lt 21 Door 64.0 2 Metal Slider 0.770 180 90 0.75 0.40 Roller.Lt 22 Window 32.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 23 Window 16.0 2 None Slider 0.570 270 90 0.88 0.78 Default.dra COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -FORM C -2R User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description 24 Window 10.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 25 Window 40.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 26 Window 10.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 27 Window 10.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 28 Window 40.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 29 Window 10.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 30 Window 25.0 2 Metal Slider 0.750 180 90 0.75 0.40 Roller.Lt 31 Window 10.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 32 Window 40.0 2 Metal Slider 0.600 180 90 0.75 0.40 Roller.Lt 33 Door 64.0 2 Metal Slider 0.770 90 90 0.75 0.40 Roller.Lt 34 Skylight 4.0 2 Metal Fixed 0.800 180 0 0.36 0.36 Medium wht 35 Skylight 4.0 2 Metal Fixed 0.800 180 0 0.36 0.36 Medium wht 36 Skylight 4.0 2 Metal Fixed 0.800 180 0 0.36 0.36 Medium wht OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 9.0 3 3 9.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 15.0 5 3 3 0 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 20.0 4 4 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 15.0 5 3 15 0 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 64.0 8 8 6 0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 16.0 8 2 15 0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 64.0 8 8 3 0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Door 64.0 8 8 3 0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 10.0 2 5 12 0 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 40.0 8 5 12 3 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 10.0 2 5 15.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 40.0 8 5 15.5 3 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 10.0 2 5 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 40.0 8 5 2 3 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 20.0 2 10 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 16 Door 88.0 8 11 2 3 n/a n/a n/a n/a n/a n/a n/a n/a 18 Door 64.0 8 8 3 0 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 52.0 6 8.67 3 0 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 32.0 8 8 3 0 n/a n/a n/a n/a n/a n/a n/a n/a 21 Door 64.0 8 8 3 0 n/a n/a n/a n/a n/a n/a n/a n/a 22 Window 32.0 8 4 3 0 n/a n/a n/a n/a n/a n/a n/a n/a 24 Window 10.0 2 5 2.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 25 Window 40.0 8 5 2.5 3 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 10.0 2 5 2.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 27 Window 10.0 2 5 2.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 28 Window 40.0 8 5 2.5 3 n/a n/a n/a n/a n/a n/a n/a n/a 29 Window 10.0 2 5 2.5 0 n/a n/a n/a n/a n/a n/a n/a n/a 30 Window 25.0 5 5 1.25 3 n/a n/a n/a n/a n/a n/a n/a n/a 31 Window 10.0 2 5 2.5 0 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program-FORM'C-2R User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED OVERHANGS AND SIDE FINS Window- Overhang Left Fin Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext 32 Window 40.0 8 5 2.5 .3 n/a n/a n/a 33 Door 64.0 8 8 5.5 0 n/a .n/a n/a EXTERIOR SHADING Mass Type HOUSE 1 S1abOnGrade 2 SlabOnGrade Right Fin - Dpth Hght Ext Dpth Hght n/a n/a n/a n/a n/a- n/a n/a n/a n/a n/a Area Shading SC of Surface (sf) Type Ext Shade HOUSE 1 Window 9.0 50% bug scrn 0.84 2 Window 15.0 50% bug scrn 0.84 3 Window 20.0 50% bug scrn 0.84 4 Window 15.0 50% bug scrn 0.84 5 Door 64.0 50% bug scrn 0.84 7 Door 64.0 50% bug scrn 0.84 8 Door 64.0 50% bug scrn 0.84 16 Door 88.0 50% bug scrn 0.84 17 Window 15.0 50% bug scrn .0.84 18 Door 64.0 50% bug scrn 0.84 21 Door 64.0 50% bug scrn 0.84 30 Window 25.0 50% bug scrn 0.84 33 Door 64.0 50% bug scrn 0.84 THERMAL MASS Area Thick Heat Conduct- Surface (sf) (in) Cap ivity R -value Location/Comments 980 3.5 28.0 0.98 R-0.0 SEE SCHEDULE 2350 3.5 28.0 0.98 R-2.0 HVAC SYSTEMS Minimum System Type Efficiency HOUSE Furnace 0.800 AFUE ACSplit 12.00 SEER Duct Location Attic Attic Duct Puct R -value Efficiency R-4.2 0.830 R-4.2 0.810 HVAC SIZING Page 1 HVAC Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 Pro ct �e Add 79-140 BIG HOR ress........ N TRAIL PAINTED COVE, LA QUINTA Documentation Author... CATHERINE M. MADLIN Company .............. Madlin's Enterprises Telephone.............. 619-323-3644 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Field ec Date MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED GENERAL INFORMATION Floor Area ................. Volume.. . ............ Front Orientation.......... Sizing Location............ Latitude... ......... Winter outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range.... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 3330 sf 29970 cf Front Facing PALM DESERT 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Heating Description (Btuh) 180 deg (S) Cooling (Btuh) Opaque Conduction and Solar...... 19296 9584 Glazing Conduction ............... 28087 25130 Glazing Solar .................... n/a 26489 Infiltration ..................... 15826 10473 Internal Gain .................... n/a 3350 Ducts ............................ 6321 7503 Sensible Load .................... 69529 82529 Latent Load ...................... n/a 16506 Minimum Total Load 69529 99035 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED HEATING LOAD CALCULATIONS DESIGN CONDITIONS FOR ZONE 'HOUSE': WINTER DESIGN TEMPERATURES: InsideTemperature ................................ 70.0 F Outside Temperature ............................... 32.0 F DESIGN TEMPERATURE DIFFERENCES Standard.......................................... 38.0 F CONDUCTIVE HEAT LOSS: U -value Heat Area (Btu/hr- TD Loss Description Orientation (sgft) sqft-F) (F) (Btuh) Wall South 333 x 0.059 x 38.0 = 749 Wall West 637 x 0.059 x 38.0 = 1433 Wall North 503 x 0.059 x 38.0 = 1132 Wall East 569 x 0.059 x 38.0 = 1280 Shaded Wall n/a 320 x 0.059 x 38.0 = 720 Door South 40 x 0.330 x 38.0 = 502 Door North 24 x 0.330 x 38.0 = 301 Roof South 3330 x 0.025 x 38.0 = 3226 SlabEdge n/a 82 x 0.900 x 38.0 = 2804 SlabEdge n/a 233 x 0.720 x 38.0 = 6375 SlabEdge n/a 27 x 0.550 x 38.0 = 564 SlabEdge n/a 11 x 0.500 x 38.0 = 209 CONDUCTIVE TOTALS FOR OPAQUE SURFACES 19296 Double Window West 9 x 0.75 x 38.0 = 257 Double Window South 15 x 0.75 x 38.0 = 428 Double Window West 20 x 0.75 x 38.0 = 570 Double Window North 15 x 0.75 x 38.0 = 428 Double Door West 64 x 0.77 x 38.0 = 1873 Double Window South 16 x 0.57 x 38.0 = 347 Double Door North 64 x 0.77 x 38.0 = 1873 Double Door North 64 x 0.77 x 38.0 = 1873 Double Window North 10 x 0.60 x 38.0 = 228 Double Window North 40 x 0.60 x 38.0 = 912 Double Window West 10 x 0.60 x 380 = 228 Double Window West 40 x 0.60 x 38.0 = 912 Double Window North 10 x 0.60 x 38.0 = 228 Double Window North 40 x 0.60 x 38.0 = 912 Double Window North 20 x 0.60 x 38.0 = 456 Double Door North 88 x 0.77 x 38.0 = 2575 Double Window North 15 x 0.75 x 38.0 = 428 Double Door North 64 x 0.77 x 38.0 = 1873 Double Window East 52 x 0.60 x 38.0 = 1186 Double Window East 32 x 0.60 x 38.0 = 730 Double Door South 64 x 0.77 x 38.0 = 1873 Double Window South 32 x 0.60 x 38.0 = 730 Double Window West 16 x 0.57 x 38.0 = 347 Double Window South 10 x 0.60 x 38.0 = 228 HVAC SIZING Page 3 HVAC- Project VACProject Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -HVAC SIZING User#k-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED Double Window South 40 x 0.60 x 38.0 = 912 Double Window South 10 x 0.60 x 38.0 = 228 Double Window South 10 x 0.60 x 38.0 = 228 Double Window South 40 x 0.60 x 38.0 = 912 Double Window South 10 x 0.60 x 38.0 = 228 Double Window South 25 x 0.75 x 38.0 = 713 Double Window South 10 x 0.60 x 38.0 = 228 Double Window South 40 x 0.60 x 38.0 = 912 Double Door East 64 x -0.77 x 38.0 = 1873 Double Skylight Horizontal 4 x 0.80 x 38.0 = 122 Double Skylight Horizontal 4 x 0.80 x 38.0 = 122 Double Skylight Horizontal 4 x 0.80 x 38.0 = 122 CONDUCTIVE TOTALS FOR GLAZING SURFACES 28087 INFILTRATION: (Type: Medium) 29970 cuft x 0.77 ac/hr x 0.018 Btu/cuft-F x 38.0 = 15826 SUBTOTAL 63208 DUCT HEAT LOSS: Duct Location: Attic 0.10 x 63208 = 6321 TOTAL HEATING LOAD: COOLING LOAD CALCULATIONS DESIGN CONDITIONS FOR ZONE 'HOUSE': . 69529 SUMMER DESIGN CONDITIONS: Inside Temperature ............................... 78.0 F Outside Temperature...............................112.0 F Temperature Range ................................. 34.0 F DESIGN EQUIVALENT TEMPERATURE DIFFERENCES Standard........ ................................. 34.0 F Frame Walls and Doors............................. 32.6 F' Ceiling Under Vented Attic ........................ 53.0 F Frame Partitions .................................. 24.0 F CONDUCTIVE HEAT GAIN: U -value Heat Area (Btu/hr- TDeq Gain Description Orientation (sqft) sqft-F) (F) (Btuh) Wall South 333 x 0.059 x 32.6 = 643 Wall West 637 x 0.059 x 32.6 = 1230 Wall North 503 x 0.059 x 32.6 = 971 Wall East 569 x 0.059 x 32.6 = 1098 Shaded Wall n/a 320 x 0.059 x 24.0 = 455 Door South 40 x 0.330 x 32.6 = 430 Door North 24 x 0.330 x 32.6 = 258 Roof South 3330 x 0.025 x 53.0 = 4500 HVAC SIZING Page 4 HVAC Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED CONDUCTIVE TOTALS FOR OPAQUE SURFACES 9584 Double Window West 9 x 0.75 x 34.0 = 230 Double Window South 15 x 0.75 x 34.0 = 383 Double Window West 20 x 0.75 x 34.0 = 510 Double Window North 15 x 0.75 x 34.0 = 383 Double Door West 64 x 0.77 x 34.0 = 1676 Double Window South 16 x *0.57 x 34.0 = 310 Double Door North 64 x 0.77 x 34.0 = 1676 Double Door North 64 x 0.77 x 34.0 = 1676 Double Window North 10 x 0.60 x 34.0 = 204 Double Window North 40 x 0.60 x 34.0 = 816 Double Window West 10 x 0.60 x 34.0 = 204 Double Window West 40 x 0.60 x 34.0 = 816 Double Window North 10 x 0.60 x 34.0 = 204 Double Window North 40 x 0.60 x 34.0 = 816 Double Window North 20 x 0.60 x 34.0 = 408 Double Door North 88 x 0.77 x 34.0 = 2304 Double Window North 15 x 0.75 x 34.0 = 383 Double Door North 64 x 0.77 x 34.0 = 1676 Double Window East 52 x 0.60 x 34.0 = 1061 Double Window East 32 x 0.60 x 34.0 = 653 Double Door South 64 x 0.77 x 34.0 = 1676 Double Window South 32 x 0.60 x 34.0 = 653 Double Window West 16 x 0.57 x 34.0 = 310 Double Window South 10 x 0.60 x 34.0 = 204 Double Window South 40 x 0.60 x 34.0 = 816 Double Window South 10 x 0.60 x 34.0 = 204 Double Window South 10 x 0.60 x 34.0 = 204 Double Window South 40 x 0.60 x 34.0 = 816 Double Window South 10 x 0.60 x 34.0 = 204 Double Window South 25 x 0.75 x 34.0 = 638 Double Window South 10 x 0.60 x 34.0 = 204 Double Window South 40 x 0.60 x 34.0 = 816 Double Door East 64 x 0.77 x 34.0 = 1676 Double Skylight Horizontal 4 x 0.80 x 34.0 = 109 Double Skylight Horizontal 4 x 0.80 x 34.0 = 109 Double Skylight Horizontal 4 x 0.80 x 34.0 = 109 CONDUCTIVE TOTAL FOR GLAZING SURFACES 25130 1 SOLAR HEAT GAIN: Heat Area Shading Gain Description Orientation (sqft) SHGF Coeff. (Btuh) Double Window West 9 x 73 x 0.65 = 429 Double Window South 15 x 32 x 0.65 = 313 Double Window West 20 x 73 x 0.65 = 953 Double Window North 15 x 15 x 0.65 = 147 Double Door West 64 x 73 x 0.65 = 3051 Double Window South 16 x 32 x 0.84 = 432 Double Door North 64 x 15 x 0.65 = 627 Double Door North 64 x 15 x 0.65 = 627 Double Window North 10 x 15 x 0.65 = 98 HVAC SIZING Page 5 HVAC Project Title.......... HENDREN RESIDENCE Date........ 06/28/95 MICROPAS4 v4.02 File -15890A17 Wth-CTZ15S92 Program -HVAC SIZING User#-MP1069 User-Madlin's Enterprises Run -SKYLIGHTS ADDED Double Window North 40 x 15 x 0.65 = 392 Double Window West 10 x 73 x 0.65 = 477 Double Window West 40 x 73 x 0.65 = 1907 Double Window North 10 x 15' x 0.65 = 98 Double Window North 40 x 15 x 0.65 = 392 Double Window North 20 x 15 x 0.65 = 196 Double Door North 88 x 15 x 0.65 = 862 Double Window North 15 x 15 x 0.65 = 147 Double Door North 64 x 15 x 0.65 = 627 Double Window East 52 x 73 x 0.65 = 2479 Double Window East 32 x 73 x 0.65 = 1526 Double Door South 64 x 32 x 0.65 = 1337 Double Window South 32 x 32 x 0.65 = 669 Double Window West .16 x 73 x 0.84 = 986 Double Window South 10 x 32 x 0.65 = 209 Double Window South 40 x 32 x 0.65 = 836 Double Window South 10 x 32 x 0.65 = 209 Double Window South 10 x 32 x 0.65 = 209 Double Window South 40 x 32 x 0.65 = 836 Double Window South 10 x 32 x 0.65 = 209 Double Window South 25 x 32 x 0.65 = 522 Double Window South 10 x 32 x 0.65 = 209 Double Window South 40 x 32 x 0.65 = 836 Double Door East 64 x 73 x 0.65 = 3051 Double Skylight Horizontal 4 x 152 x 0.32 = 197 Double Skylight Horizontal 4 x 152 x 0.32 = 197 Double Skylight Horizontal 4 x 152 x 0.32 = 197 EXTERIOR SOLAR TOTAL (Sext) 26489 INFILTRATION: (Type: Medium) 29970 cuft x 0.57 ac/hr x 0.018 Btu/cuft-F x 34.0 = INTERNAL GAIN: 6 People x 225 Btu/person + 2000 Btu (appliance) _ DUCT HEAT GAIN: Duct Location: Attic LATENT LOAD: SUBTOTAL 0.10 x 75027 = 10473 3350 75027 7503 E TOTAL HOURLY SENSIBLE HEAT GAIN 82529 0.20 x 82529 = 16506 TOTAL COOLING LOAD 99035 MADLIN'S ENTERPRISES Title 24 Energy Calculations and Consulting Post Office Box 1443 • Palm Springs, California 92263 Telephone (619) 324-1731 Table G-4: Manufactured Fenestration Product Default U -Values t. The minimum design characteristics to qualify as a thermal Break Product are: a. The material "as the thermal break must have a thermal conductivity of not more than 3.6 Bw-inch/hr/ft /OF. and; b. The thermal break must produce a gap of not less than 0210', and; c. All metal members of the product exposed to interior and arterior air must incorporate a them W- break meeting the criteria in (a) and (b) above. In addition, the product must be clearly labeled by the manufacturer Lt wit it qualifies as a thermally broken product in accordance with Commission requirements. 2. Non-metal products can include metal fasteners, hardware and door thresholds. 3. Add 0.04 to the listed U -value for any products that have metal cladding in any configuration. 4. For all dual glazed fenestration products adjust the listed U -values as follows: a. Subtract 0.05 for spacers of 7/16' or wider. b. Subtract 0.05 for Low•E glazing. c. Add 0.05 for products with dividers between the panes if the spacer is less that 7/16- wide. it. Add 0.05 to any product with we divided lites (dividers through the panes). Table G -S: Site Built Fenestration Product U -Values Framing Materials Framing MatErials Non -Metal, except Any Metal, including Fastener Hardware Cladding T et}-rma� Single Double Single Double Fixed 1.19 0.72 Any Metal llreak Non-Metal213 Single . Double" • Double4 Single Double" Operable Windows 1.28 0.87 0.71 0.92 0.60 Fixed Windows 1.19 0.72 0.60 1.04 0.57 Patio Door 1.25 0.77 0.68 0.99 0.55 Skylights 1.26 (0>0.70 0.91 0.55 Greenhouse Windows 2.26 1.40 1.12 1.94 1.06 t. The minimum design characteristics to qualify as a thermal Break Product are: a. The material "as the thermal break must have a thermal conductivity of not more than 3.6 Bw-inch/hr/ft /OF. and; b. The thermal break must produce a gap of not less than 0210', and; c. All metal members of the product exposed to interior and arterior air must incorporate a them W- break meeting the criteria in (a) and (b) above. In addition, the product must be clearly labeled by the manufacturer Lt wit it qualifies as a thermally broken product in accordance with Commission requirements. 2. Non-metal products can include metal fasteners, hardware and door thresholds. 3. Add 0.04 to the listed U -value for any products that have metal cladding in any configuration. 4. For all dual glazed fenestration products adjust the listed U -values as follows: a. Subtract 0.05 for spacers of 7/16' or wider. b. Subtract 0.05 for Low•E glazing. c. Add 0.05 for products with dividers between the panes if the spacer is less that 7/16- wide. it. Add 0.05 to any product with we divided lites (dividers through the panes). Table G -S: Site Built Fenestration Product U -Values Framing Materials Non -Metal, except Any Metal, including Fastener Hardware Cladding and Door Thresholds Single Double Single Double Fixed 1.19 0.72 1.04 0.57 Operable 1.32 0.93 0.99 0.55 t 5 R38 National Fenestration Rating Council'- Certified Products Directory Manufacturer, Product Line ID, Product Type, and Manufacturer's Designation , Rating Date - IA 003 Glazing Description 2 Thermal Performance Individ. Product Number Frame Type No. of Layers Low -E Coatings and/or Films Gap Width Spacer Type Gri Gap Fill Test Only U -Value AA Site U -Value 88 Size Low -E, (Surface) Film. (Surface) Metal Windows Cor oration 031-001 Casement/Confi uratlon Unknown 1500/2 00. 913C 3 - A 003 AP 2 .200.(3) .50 At Al AIR AIR 0.49 0.46 004 AP 2 .200.(3) .50 At Al ARG AIR 0.46 0.43 005 AP 3 .114.(3) 4 .31/.31 S1 Al AIR ARG 0.42 0.39 006 AP 3 .114.(3) .31/.31 Si A 1 ARG ARG 0.39 0.35 007 AP 2 .114.(3) .50 Al T AIR AIR 0.63 0.61 008 AP 2 .114, (3) .50 At T 'ARG AIR 0.63 • 0.61 009 AP 2 .200, (3) .50 Al T AIR ARG 0.56 0.52 010 AP 2 .200.(3) .50 Al T ARG ARG 0.55 0.51 011 AP 3 .114, (3) .31/.31 S1 T AIR AIR 0.49 0.45 012 AP 3 .114, (3) .31/.31 S1 I T ARG AIR 0.47 0.43 Metal Windows Cor oration 031-002 Protected/Awnin 1500/200 9/30/93 - A 001 AP 2 2 .50 Al Al AIR AIR 0.57 •0.56 002 AP 2 2 .50 Al Al ARG AIR 0.55 0.54 003 AP 2 .200, (3) .50 • A 1 Al AIR ARG 0.49 0.46 004 AP 2 .200, (3) .50 Al A 1 ARG ARG 0.46 0.43 005 AP 3 .114.(3) .31/.31 GS Al AIR AIR 0.42 0.39 006 AP 3 .114, (3) .31/.31 GS Al ARG AIR 0.39 0.35 007 AP 2 2 .50 Al T AIR ARG 0.63 0.61 008 AP 2 2 .50 A 1 T ARG ARG 0.63 0.61 009 AP 2 .200.(3) .50 Al T AIR AIR 0.56 0.52 010 AP 2 .200.(3) .50 Al T ARG AIR 0.55 0.51 011 AP 3 .114, (3) .31/.31 GS T AIR ARG 0.49 0.45 012 AP 3 .114, (3) .31/.31 GS I T ARG ARG 0.47 0.43 Metal Windows Cor oration 031-003 Fixed/Confi uratlon Unknown 1500/2000. 9/30/93 - A 001 AP 2 2 .50 A 1 Al AIR AIR 0.53 0.52 002 AP 2 2 .50 Al Al ARG AIR 0.50 0.49 003 AP 2 .200.(3) .50 Al Al AIR. ARG 0.41 0.40 004 AP 2 .200.(3) .50 Al A 1 ARG ARG 0.37 0.36 005 AP 3 .114, (3) .31/.31 GS Al AIR AIR 0.31 0.30 006 AP 3 .114, (3) .31/.31 GS Al ARG AIR 0.28 0.27 007 AP 2 2 .50 A 1 T AIR ARG 0.60 0.59 008 AP 2 2 .50 A 1 ' T ARG ARG 0.56 0.56 009 AP 2 .200.(3) .50 Al T AIR AIR 0:50 0.49 010 AP 2 .200, (3) .50 Al T ARG AIR 0.47 0.46 011 AP 3 .114, (3) .31/.31 GS T AIR ARG 0.40 0.39 012 AP 3 .114, (3) .31/.31 GS T ARG ARG 0.37, 0.36 Mil and M nufact inQ. 032-001 Fixed/Configuration Unknown -1 6 - A 001 AL 2 .36 Al Y AIR 0.61 0.60 002 AL 2 .36 Al AIR 0.61 0.59 003 AL 2 .36 Al Y ARG 0.59 0.57 004 AL 2 .36 A 1 ARG dfM 0.56 005 AL 2 .200.(3) .36 Al Y AIR 1 0.49 006 AL 2 .200, (3) .36 Al AIR 0.50 0.48 007 AL 2 .200, (3) .36 Al Y ARG 0.45 0.47 008 AL 2 .200, (3) .36 Al ARG 0.45 0.43 009 AL 2 .51 A/ AIR 0.59 0,57 010 AL 2 .51 Al Y AIR 0.59 0.57 011 AL 2 .51 Al ARG 0.56 0.55 012 AL 2 .51 Al Y ARG 0.57 0.55 013 AL 2 .200, (3) .51 A 1 AIR 0.46 0.44 014 AL 2 .200, (3) .51 Al Y AIR 0.47 0.46 015 AL 2 .200, (3) .51 A 1 ARG 0.43. 0.41 016 AL 2 .200, (3) .51 Al Y ARG 0.44 0.43 Products A41horized for Certification as of December 15„ J993 National Fenestration Rating Council - Certified Products Directory R41 Manufacturer, Product Line ID, Product Type, and Manufacturer's Designation , Rating Date - IA Double Door/Silding Glass Door. 5621 Wide Stile. 7/08/93 - A Glazing Description VY Thermal Performance Indivld. Product Number Frame Type No. of Layers Low -E Coatings and/or Films Gap Width SpacerL11PI Type GridOnly 0.30 Test U -Value AA Size U -Value BB Size Low -E, (Surface) IFilm, (Surface) MII and Manufacturing. 032-010 Double Door/Silding Glass Door. 5621 Wide Stile. 7/08/93 - A 008 VY 3 .200, (5) .114, (3) 38/.38 GS A4 ARG AIR 0.30 0.30 009 VY 3 1 .114.(3) 38/.38 GS A4 KRY AIR 0.31 0.30 010 VY 3 .200, (5) .114, (3) ` 38/.38 GS A4 KRY ARG 0.28 0.28 Mil and Menufacturin 032-011 Casement/Confi quration Unknown. 910-C 6/30/93 - A 001 AL 2 .375 .375 A4 Y AIR 0.78 0.76 0.71 002 AL, 2 .400.(3) .375 A4 AIR AIR 0.78. 0.75 0.71 003 AL 2 .200, (3) .375 A4 Y ARG 0.73 0.69 004 AL 2 .375 .375 A4 ARG ARG 75 A jQ 0.73 0.68 005 AL 2 .200, (3) .375 A4 Y AIR 0.68' 0.63 006 AL 2 .200, (3) .375 A4 AIR AIR 0.68 0.67 0.62 007 AL 2 .200, (3) .375 A4 Y ARG 0.66, 0.65 '0.59 ' 008 AL 2 .200, (3) .375 A4 ARG ARG 0.64 0.63 0.58 009 AL 2 .200, (5) .114, (3) .51 A4 AIR AIR 0.76 0.73 0.69•. 010 AL 2 .200, (5) .1 14, (3) .51 A4 ARG ARG 0.74 0.71 0.67 011 AL 2 .200, (3) .51 A4 AIR AIR 0.65 0.64 0.58 012 AL 2 .200, (3) .51 A4 ARG ARG 0.61 0.61, 0.55 013 AL 2 .51 .51 A4 Y AIR 0.76 0.73 0.69 _ 014 AL 2 .51 _ .51 A4 Y ARG 0.74 0.72. 0.67 015 AL 2 .200, (3). .51 A4 Y AIR 0.66 0.65 0.59 016 AL 2 .200, (3) .51 A4 Y ARG .0.63, 0.62 0.57 Mit and Manufacturin 032-012 Casement/Cbnfi uratlon Unknown 920/930 6/15/93 - A 001 AT 2 .375 .75 Al AIR AIR 0.78 0.61 0,59 002 AT 2 .400.(3) .75 Al AIR AIR 0.78. 0.55 0,53 003 AT 2 .200, (3) .75 A 1 ARO AIR 0.52 0.49 004 AT 2 .375 .75 Al ARG ARG 75 A jQ 0.59 0.57 005 AT 2 .400, (3) .75 Al AIR ARG 0.53 0.50,' 006 AT 2 .200, (3) .75 Al AIR ARG 0.68 0.49 0.46 007 AT 3 .1 14, (3) .38/.38 A 1 ARG AIR 0.66, 0.41 0.38 008 AT 3 .200, (5) .114.(3) .38/.38 Al ARG AIR 0.64 0.39 0.36 009 AT 3 .200, (5) .114, (3) .38/.38 A 1 AIR ARG 0.76 0.36 0.33 010 AT 3 .200, (5) .1 14, (3) .38/.38 Al ARG KRY 0.74 0.34 0.30 ME Mil and Menufacturin 032-013 Horizontal Slide r/Fixed/O arable 1110. 6/15/93 - A or 001 AL 2 .375 A4 Y AIR 0.78 0.7 002 AL 2 .375 A4 AIR 0.78. 0.73 003 AL 2 .375 A4 Y ARO 00.71 004 AL 2 .375 A4 ARG 75 A jQ 0.70 005 AL 2 .200, (3) .375 A4 Y AIR 0.63 006 AL 2 .200, (3) .375 A4 AIR 0.68 0.62 007 AL 2 .200, (3) .375 A4 Y ARG 0.66, 0.60 008 AL 2 200,(3) .375 A4 ARG 0.64 0.58 .009 AL 2 .51 A4 AIR 0.76 0.70 010 AL 2 .51 A4 ARG 0.74 0.68 011 AL 2 .200, (3) .51 A4 AIR 0.65 0.59 012 AL 2 .200.(3) .51 A4 ARG 0.61 0.55 , 013 AL 2 .51 A4 Y AIR 0.76 0.71 014 AL 2 .51 _ A4 Y ARO 0.74 0.68 015 AL 2 .200, (3) .51 A4 Y AIR 0.66 0.60 016 AL 2 .200, (3) .51 A4 Y ARG .0.63, 0.57 I•001 AT 2 .63 At AIR 0.654 051 002 AT I 2 I • .400, (3) I .63 I Al I I AIR I 0.58 0.55 I Products Authorized for Certification as of December 15, 1993 National Fenestration Rating Council - Certified Products Directory R43 Manufacturer, Product Line ID, Product Type, and Manufacturer's Designation , Rating Date - IA Horizontal Slider Fixed/O erable 5120/5120-C.'5,18/93 - Glazing Description VI Thermal Performance Indlvld. Product Number Frame Type No. of Layers Low -E Coatings and/or Films Gap Width Spacer Type Grid Gap Fill Test Only U-V81Ue AA Size U-V81Ue BB Slze Low -E, (Surface) Film, (Surface) MII and ManufacturIna. 032-017 Horizontal Slider Fixed/O erable 5120/5120-C.'5,18/93 - 017 VI 3 . .200.(5) .114, (3) .31/.31 S1 B ARG 0.27 0.25 018 %Y 3 .200.(5) .114.(3) .38/.38 S1 Y KRY 0.26 0.25 019 VI 3 .200, (5) .114, (3) .38/.38 S1 B KRY 0.23 0.22 . 020 VI 3 .200.(S) .114, (3) .38/.38 S1 Y KRY 0.23 0.22 MII and M nufacturIna. 032-01 ed nfl au ration nkn wn R-2 /9 - A 001 AT 2 .200, (3) .81 Al B AIR 0.55 0.5 002 AT 2 .400, (3) .81 A 1 Y AIR 0.48 0.47 003 AT 2 .200.(3) .81 Al B AIR 0.43 0.42 004 AT 2 .200, (3) .81 A 1 Y ARG 0.52 0.52 005 AT 2 .400, (3) .81 A 1 B ARG 0.44• 0.43 006 AT 2 .200.(3) .81 A 1 B ARG 0.39 0.38 007 AT 3 .114, (3) .38/.38 S2 B AIR 0.32 0.31 008. AT 3 .200.(5) .114.(3) .38/.38 S2 B AIR 0.30 0.28 009 AT 3 .200.(5) .114, (3) .38/.38 S2 ARG 0.26 0.24 010 AT 3 .200, (5) .114.(3) .38/.38 S2 KRY 0.23 1 0.21 Mil and Manufacturin 032-019 Doouble Door/SlIdlna GlassDoor. 410. 8/27/93 - Aan 001 AL 2 .200, (3) .375 A 1 B AIR 0.69 0.67 002. AL 2 .200.(3) .375 At Y AIR 0.72 0.70 003 AL 2 .200, (3) .375 Al B ARG 0.64 t 0.63 ` 004 AL 2 .200, (3) .375 Al Y ARG 0.69 0.67 MII and Menufacturin 032-020 Fixed/Conflouratlon Unknown 91 0- /911-C 10/20/93 - A 001 AL 2 .36 Al B AIR 0.63 0.62 002 AL 2 .36 Al B ARG 0.61 0.59 003 AL 2 .200.(3) .36 Al B AIR 0.53 0.51 004 AL 2 .200.(3) .36 Al B ARG 0.50 0.48 005 AL 2 .51 Al B AIR 0.61 0.59 006 AL 2 .51 Al B ARG 0.58 0.57 007 AL 2 .200, (3) .51 Al B AIR 0.50 0.48 008 AL 2 .200, (3) .51 Al B ARG 0.47 0.45 009 AL 2 .55 Al AIR 0.60 0.59 010 AL 2 .55 Al ARG 0.58 0.56 011 AL 2 .200.(3) .55 Al AIR 0.49 0.47 012 AL 2 .200.(3) .55 Al ARG 0.45 0.43 013 AL 2 i .61 Al AIR 0.61 0.59 014 AL 2 .61 Al ARG 0.59 0.57 015 AL 2 .200, (3) .61 Al AIR 0.50 } 0.48 016 AL 2 .200, (3) .61 Al ARG 0.46 0.44 017 AL 2 i .76 Al AIR 0.61 0.59 018 AL 2 .76 Al ARG 0.59 0.57 019 AL 2 .200, (3) .76 Al AIR 0.50 0.48 020' AL 2 .200, (3) .76 Al ARG 0.46 0.44 021 AL 2 .80 Al AIR 0.61 0.59 022 AL 2 .80 Al ARG 0.59 0.57 023 AL 2 .200, (3) .80 Al AIR 0.50 0.48 024 AL 2 .200, (3) .80 Al ARG 0.46 0.44 MII and Menufacturin 032-021 Horizontal Slider/Fixed/O erable 1110- /1180 -C/1280 -C 10/14/93 - A 001 AL 2 .51 Al AIR 0.74 0.69 002 AL 2 51 Al ARG 0.72 0.67 003 AL 2 .200.(3) .51. Al AIR 0.63 0.57 004 AL 2 .200, (3) .51 A 1 ARG 0.59 0.54 005 AL 2 .51 A 1 Y AIR 0.74 0.69 Products Authorized for Certification as of December 15, 1993 CalCERTS Page 3 of 14 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8) CF -411 79140 Big Horn Trail - La Quinta, CA 92253 Palm Desert A/C - Heating / 374937 Project Address Contractor Name / License No. 07-1920 Contractor Contact Telephone Permit Number Paul Van Vlymen 760-777-1724 76491 HM Rater Telephone Sample Group Number �j August 17, 2007 CC14-1798417063 CerWing Signature Date Certiilcate Number Firm: Air Experts Air Conditioning HERS Provider:CaICERTS, Inc. Street Address: PO Box 94 City/State/Zip: La Quinta / CA / 92247 Copies to: Homeowner, HERS Provider and Building Department This CF -4R has been registered with the CaICERTS® registry in accordance with the Title 24 & Tide 20 of the CCR. CaICERTS@ is an approved HERS provider by the California Energy Commission. HERS RATER COMPLIANCE STATEMENT The house was ❑Tested © Approved as part of sample testing, but was not tested. As the HERS rater providing diagnostic testing and field verification, I certify that the house Identified on this form complies with the diagnostic tested compliance requirements as checked on this form. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a CF -411 may be released on every tested building. The HERS rater must not release the CF -411 until a properly completed and signed CF -611 has been received for the sample and tested buildings. The installer has provided a copy of the CF -6R (Installation Certificate). New Distribution system Is fully ducted (i.e., does not use building cavities as plenums or platform returns In lieu of ducts). New systems where cloth backed, rubber adhesive duct tape Is installed, mastic and drawbands are used In combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT: NEW CONSTRUCTION Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values 1 N/A 2 Fan Flow: Calculated (Nominal '-.: - Cooling ''...•' Heating) or-.-.: Measured Not Tested Enter Total Fan Flow In CFM: 3 N/A N/A ALTERATIONS: Duct System and/or HVAC Equipment Change -Out 4 Enter Tested Leakage Flow In CFM from CF -6R: Pre -Test of Existing Duct System Prior to Not Tested Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System 5 Not Tested for Duct System Alteration and/or Equipment Change -Out. 6 Enter Reduction in Leakage for Altered Duct System Not Tested [Une 4 - Une 5] - (Only if Applicable) 7 Enter Tested Leakage Flow In CFM to Outside (Only if Applicable) Not Tested 8 Entire New Duct System - Pass If Leakage Percentage < 6% [ 100 x ( Une 5 / Une 2 )]: Not Tested ❑ Pass ❑ Fall TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change -Out, use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage <= 15% [ 100 x ( Une 5 / Une 2 )]: Not Tested ❑ Pau ❑ Fall 10 Pass If Leakage to Outside Percentage <= 10% [ 100 x ( Une 7 / Line 2 )]: Not Tested I ❑ Pass ❑ Fail 11 Pass if Leakage Reduction Percentage >= 60% [ 100 x ( Une 6 / Line 4 )] Not Tested ❑ Pass ❑ Fail and Verification by Smoke Test and Visual Inspection 12 Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail Pass if One of Lines #9 through #12 pass ❑ Pass ❑ Fail ,CaICERTS Page 4 of 14 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 3-4 of 8) CF -411 79140 Big Horn Trail - La Quinta, CA 92253 Palm Desert A/C - Heating / 374937 Project Address Contractor Name / License No. 07-1920 Contractor Contact Telephone Permit Number ul Van Vl men 760-777-1724 76491 HE Rater Telephone Sample Group Number l / 9ust 17, 2007 CC14-1798417063 ertl6dng Signature Date Certificate Number Firm: Air Experts Air Conditioning HERS Provider:Ca10ERTS, Inc. Street Address: PO Box 94 City/State/Zip:La Quinta / CA / 92247 Cooies to: Homeowner, HERS Provider and Buildinq Department This CF -411 has been registered with the CaICERTSO registry in accordance with the Title 24 & Title 20 of the CCR. CaICERTS® is an approved HERS provider by the California Energy Commission. HERS RATER COMPLIANCE STATEMENT The house was ❑Tested 0 Approved as part of sample testing, but was not tested. As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the dia nostic tested compliance requirements as checked on this form. 91 The installer has provided a copy of the CF -611 (Installation Certificate). LITHERMOSTATIC EXPANSION VALVE TXV Access is provided for inspection. The procedure shall consist of visual verification that the TXV is installed on the system and installation of the specific equipment shall be verified. HVAC System TXV ❑ Pass ❑ Fail