0008-422 (SFD) Title 24TABLE OF CONTENTS TOC
Project Title.......... SINGLE FAMILY HOME-Date..08/23/00 13:05:04
F t Add LOT 24 ("AHUILLA COURT *******
.rojec ress........
LA QUINTA *v5.10*
Documentation Author... DANA, CEA *******
West Coast Energy Design
7354 Dover Lane
Dublin, CA 94568
925-829-5304
Climate Zone 15
Compliance Method...... MICROPAS5 x5.10 for 1998 Standards by Enercomp, Inc.
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -TOC
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
TABLE OF CONTENTS
Report
FORM CF -1R.
FORM C -2R .................
Y
HVAC SIZING ...............
CITY O r.T;
,t `r r
BUILDING & T
RePP
FOR CO.;;..
I DATE _----- `j -
CITY OF LA c)uiNTA
BUILDING & SAFETY DEPT.
r
APPROVE
FOR CONSTRUCTION
I DATE—
_.__ --
Page
1
4
8
Building
Permit
Plan
Check Date
Field
Check/ Date
Compliance Method...... MICROPAS5 x5.10 for 1998 Standards by Enercomp, Inc.
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -TOC
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
TABLE OF CONTENTS
Report
FORM CF -1R.
FORM C -2R .................
Y
HVAC SIZING ...............
CITY O r.T;
,t `r r
BUILDING & T
RePP
FOR CO.;;..
I DATE _----- `j -
CITY OF LA c)uiNTA
BUILDING & SAFETY DEPT.
r
APPROVE
FOR CONSTRUCTION
I DATE—
_.__ --
Page
1
4
8
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... SINGLE FAMILY HOME Date..08/23/00 13:05:04
F t Add 2
*******
�ec ........
LOT
J_oress4, CAHUILLA COURT
LA QUINTA *v5.10*
Documentation Author... DANA, CEA ******* Building Permit
West Coast Energy Design
7354 Dover Lane Plan Check Date
Dublin, CA 94568
925-829-5304 Field Check/ Date
Climate Zone........... 15
Compliance Method...... MICROPASS v5.10 for 1998 Standards by Enercomp, Inc.
MICROPASS v5.10 File -ROSE Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Stories..........
Floor Construction Type....
Glazing Percentage.........
Average Glazing U -value....
Average Glazing SHGC.......
Average Ceiling Height.....
5975 sf
Single Family Detached
New
Front Facing 128 deg (SE)
1
1
Slab On Grade
22.6 % of floor area
0.34 Btu/hr-sf-F
0.28
12.1 ft
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing Total Assembly
Type
Type
R -value
R -value R -value U -value
Location/Comments
Wall
Wood
R-17.8
R-n/a
R-17.8 0.065
TYPICAL, SHADED
Roof
Wood
R-30
R-n/a
R-30 0.031
ATTIC
Door
Wood
R-0
R-n/a
R-0 0.330
MAIN ENTRY
S1abEdge
None
R-0
R-0
F2=0.760
TO OUTSIDE
S1abEdge
None
R-0
R-0
F2=0.510
GARAGE
FENESTRATION
Over -
Area
U-
Interior
Exterior
hang/
Orientation
(sf)
Value
SHGC
Shading
Shading
Fins
Window
Front (SE)
45.0
0.290
0.330
Standard
Standard
None
Window
Front (SE)
18.3
0.370
0.290
Standard
Standard
None
Window
Front (SE)
31.3
0.290
0.330
Standard
Standard
None
Door
Back (NW)
48.0
0.330
0.240
Standard
Standard
None
Window
Back (NW)
84.0
0.290
0.330
Standard
Standard
None
Door
Back (NW)
96.0
0.330
0.260
Standard
Standard
None
.Door
Back (NW)
112.0
0.330
0.240
Standard
Standard
None
Door
Left (SW)
96.0
0.330
0.260
Standard
Standard
None
Window
Left (SW)
51.8
0.370
0.290
Standard
Standard
None
Door
Left (SW)
56.0
0.330
0.240
Standard
Standard
None
Door
Left (SW)
96.0
0.330
0:240
Standard
Standard
None
Window
Left (SW)
41.3
0.370
0.290
Standard
Standard
None
Door
Right (NE)
48.0
0.330
0.240
Standard
Standard
None
Window
Right (NE)
27.5
0.370
0.290
Standard
Standard
None
Window
Right (NE)
82.5
0.370
0.290
Standard
Standard
None
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... SINGLE FAMILY HOME Date..08/23/00 13:05:04
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
FENESTRATION
Tank Type
Large
System
Large
Heater Type
Gas
WATER HEATING SYSTEMS
Number
in
Distribution Type System
Tank
Energy Size
Factor (gal)
Recirc/TimeTemp 1 n/a
WATER HEATING SYSTEMS DETAIL
Recovery Rated
Efficiency Input
0.76 n/a
Standby
Loss
Fraction
0.029
/5
Internal Tank
Insulation
R -value
R-n/a
External
Insulation
R -value
R-0
Pilot
Light
U
Over -
Area
U-
Interior
Exterior
hang/
Orientation
(sf)
Value
SHGC
Shading
Shading
Fins
Window
Right
(NE)
6.3
0.370
0.290
Standard
Standard
None
Window
Right
(NE)
6.3
0.290
0.330
Standard
Standard
None
Window
Front
(S)
82.5
0.370
0.290
Standard
Standard
None
Door
Front
(S)
48.0
0.330
0.240
Standard
Standard
None
Window
Front
(S)
27.5
0.370
0.290
Standard
Standard
None
Window
Right
(E)
45.0
0.290
0.330
Standard
Standard
None
Window
Right
(E)
27.5
0.370
0.290
Standard
Standard
None
Window
Right
(E)
27.5
0.370 .0.290
Standard
Standard
None
Window
Right
(E)
12.5
0.370
0.290
Standard
Standard
None
Window
Right
(E)
6.3
0.290
0.330
Standard
Standard
None
Window
Left
(W)
55.0
0.370
0.290
Standard
Standard
None
Door
Left
(W)
21.0
0.330
0.240
Standard
Standard
None
Window
Left
(W)
18.8
0.290
0.330
Standard
Standard
None
-Door
Back
(N)
24.0
0.330 .0.240
Standard
Standard
None
Window
Back
(N)
6.3
0.370
0.290
Standard
Standard
None
SLAB SURFACES
Area
Slab Type
(sf)
Standard
Slab 5975
HVAC SYSTEMS
Minimum
Duct
Duct Tested Duct ACCA
Thermostat
Equipment
Type
Efficiency
Location
R -value
Leakage Manual
D Type
Furnace
0.780 AFUE
Attic
R-4.2
No No
Setback
ACSplit
10.00
SEER
Attic
R-4.2
No No
Setback
Tank Type
Large
System
Large
Heater Type
Gas
WATER HEATING SYSTEMS
Number
in
Distribution Type System
Tank
Energy Size
Factor (gal)
Recirc/TimeTemp 1 n/a
WATER HEATING SYSTEMS DETAIL
Recovery Rated
Efficiency Input
0.76 n/a
Standby
Loss
Fraction
0.029
/5
Internal Tank
Insulation
R -value
R-n/a
External
Insulation
R -value
R-0
Pilot
Light
U
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... SINGLE FAMILY HOME Date..08/23/00 13:05:04
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Water Heating System
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
• implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.'
DESIGNER or OWNER DOCUMENTATION AUTHOR
Name.... BENJI YEN Name.... DANA, CEA
Company. HUNT HALE JONES Company. West Coast Energy Design
Address. 636 FOURTH STREET Address. 7354 Dover Lane
SAN FRANCISCO, CA 94107 Dublin, CA 94568
Phone... (415) 512-1300 Phone... 925-829-5304
License. a1 u o exist Der
Enemy y
Signed.. 45.4.00 Signed.. ���ed OV
ate ate
ENFORCEMENT AGENCY
Name ....
Title...
Agency..
.. Phone. . .
Signed.
ate
COMPUTER METHOD SUMMARY Page 4 C -2R
Project Title.......... SINGLE FAMILY HOME Date..08/23/00 13:05:04
R Add LOT 24 CAHUILLA COURT *******
roject ress........ ,
LA QUINTA *v5.10*
Documentation Author... DANA, CEA *******
West Coast Energy Design
7354 Dover Lane
Dublin, CA 94568
925-829-5304
Cl'mate Zone 15
i...........
Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc.
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92• Program -FORM C -2R
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
Energy Use
(kBtu/sf-yr)
MICROPAS5 ENERGY USE SUMMARY
Standard
Design
Proposed Compliance
Design Margin
Space Heating..........
3.20
Building
Permit
Pian
Check Date
Field
Check/ Date
i...........
Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc.
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92• Program -FORM C -2R
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
Energy Use
(kBtu/sf-yr)
MICROPAS5 ENERGY USE SUMMARY
Standard
Design
Proposed Compliance
Design Margin
Space Heating..........
3.20
2.84
0.36
Space Cooling..........
37.47
35.53
1.94
Water Heating..........
4.77
5.29
-0.52
Total
45.44
43.66
1.78
*** Building complies
with Computer
Performance
***
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U -value....
Average Glazing SHGC.......
Average Ceiling Height.....
Floor
Area Volume
Zone Type (sf) (cf)
HOUSE
Residence
6
5975 sf.
Single Family Detached
New
Front Facing 128 deg (SE)
1
1
ReducedYear
Slab On Grade
1
72083 cf
5975 sf
22.6 % of floor area
0.34 Btu/hr-sf-F
0.28
12.1 ft
BUILDING ZONE INFORMATION
# of
Dwell Cond- Thermostat
Units itioned Type
5975 72083 1.00' -Yes Setback
Vent Vent Air
Height Area Leakage
(ft) (sf) Credit
2.0 Standard No
COMPUTER METHOD SUMMARY Page 5 C -2R
Project Title.......... SINGLE FAMILY HOME Date..08/23/00 13:05:04
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -FORM C -2R
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
OPAQUE SURFACES
Area U- Insul Act Solar Form 3 Location/
Surface (sf) value R-val Azm Tilt Gains Reference Comments
HOUSE
1 Wall 271 0.065 17.8 128 90 Yes None TYPICAL
2 Wall 756 0.065 17.8 308 90 Yes None
3 Wall 662 0.065 17.8 218 90 Yes None
4 Wall 948 0.065 17.8 38 90 Yes None
5 Wall 749 0.065 17.8 173 90 Yes None
6 Wall 457 0.065 17.8 83 90 Yes None
7 Wall 301 0.065 17.8 263 90 Yes None
8 Wall 247 0.065 17.8 353 90 Yes None
9 -Wall 260 0.065 17.8 83 90 No None SHADED
10 Roof 5317 0.031 30 n/a 0 Yes None ATTIC
11 Door 48 0.330 0 128 90 Yes None MAIN ENTRY
PERIMETER LOSSES
Length F2. Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
HOUSE
12 SlabEdge 512 0.760 R-0 No TO OUTSIDE
13 SlabEdge 23 0.510 R-0 No GARAGE
FENESTRATION SURFACES
Area U- Act Exterior Shade Interior Shade
Orientation (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC
HOUSE
1 Window Front (SE) 45.0 0.290 0.330 128 90 Standard/0.76 Standard/0.68
2 Window Front (SE) 18.3 0.370 0.290 128 90 Standard/0.76 Standard/0.68
3 Window Front (SE) 31.3 0.290 0.330 128 90 Standard/0.76 Standard/0.68
4 Door Back (NW) 48.0 0.330 0.240 308 90 Standard/0.76 Standard/0.68
5 Window Back (NW) 84.0 0.290 0.330 308 90 Standard/0.76 Standard/0.68
6 Door Back (NW) 96.0 0.330 0.260 308 90 Standard/0.76 Standard/0.68
7 Door Back (NW) 112.0 0.330 0.240 308 90 Standard/0.76 Standard/0.68
8 Door Left (SW) 96.0 0.330 0.260 218 90 Standard/0.76 Standard/0.68
9 Window Left (SW) 51.8 0.370 0.290 218 90 Standard/0.76 Standard/0.68
10 Door Left (SW) 56.0 0.330 0.240 218 90 Standard/0.76 Standard/0.68
11 Door Left (SW) 96.0 0.330 0.240 218 90 Standard/0.76 Standard/0.68
12 Window Left (SW) 41.3 0.370 0.290 218 90 Standard/0.76 Standard/0.68
13 Door Right (NE) 48.0 0.330 0.240 38 90 Standard/0.76 Standard/0.68
14 Window Right (NE) 27.5 0.370 0.290 38 90 Standard/0.76 Standard/0.68
15 Window Right (NE) 82.5 0.370 0.290 38 90 Standard/0.76 Standard/0.68
16 Window Right (NE) 6.3 0.370 0.290 38 90 Standard/0.76 Standard/0.68
17 Window Right (NE) 6.3 0.290 0.330 38 90 Standard/0.76 Standard/0.68
18 Window Front (S) 82.5 0.370 0.290 173 90 Standard/0.76 Standard/0.68
19 Door Front (S) 48.0 0.330 0.240 173 90 Standard/0.76 Standard/0.68
20 Window Front (S) 27.5 0.370 0.290 173 90 Standard/0.76 Standard/0.68
21 Window Right (E) 45.0 0.290 0.330 83 90 Standard/0.76 Standard/0.68
22 Window Right (E) 27.5 0.370 0.290 83 90 Standard/0.76 Standard/0.68
23 Window Right (E) 27.5 0.370 0.290 83 90 Standard/0.76 Standard/0.68
COMPUTER METHOD SUMMARY Page 6 C -2R
Project Title.......... SINGLE FAMILY HOME Date..08/23/00 13:05:04
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -FORM C -2R
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
FENESTRATION SURFACES
Minimum Duct
System Type Efficiency Location
HOUSE
Furnace
ACSplit
Tank Type
1 Large
System
1 Large
Duct Tested Duct ACCA Duct
R -value Leakage Manual D Eff
0.780 AFUE Attic R-4.2 No
10.00 SEER Attic R-4.2 No
WATER HEATING SYSTEMS -
Heater Type
Gas
Number
in Energy
Distribution Type System Factor
Recirc/TimeTemp 1 n/a
WATER HEATING SYSTEMS DETAIL
Recovery Rated
Efficiency Input
No 0.743
No 0.596
Tank External
Size Insulation
(gal) R -value
75 R-0
Standby Internal Tank
Loss Insulation Pilot
Fraction R -value Light
0.76 n/a 0.029 R-n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
N
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Water Heating System
Area
U-
Act
Exterior Shade
Interior Shade
Orientation
(sf)
Value
SHGC
Azm Tilt
Type/SHGC
Type/SHGC
24
Window
Right
(E)
12.5
0.370
0.290
83
90
Standard/0.76
Standard/0.68
25
Window
Right
(E)
6.3
0.290
0.330
83
90
Standard/0.76
Standard/0.68
26
Window
Left
(W)
55.0
0.370
0.290
263
90
Standard/0.76
Standard/0.68
27
Door
Left
(W)
21.0
0.330
0.240
263
90
Standard/0.76
Standard/0.68
28
Window
Left
(W)
18.8
0.290
0.330
263
90
Standard/0.76
Standard/0.68
29
Door
Back
(N)
24.0
0.330
0.240
353
90
Standard/0.76
Standard/0.68
30
Window
Back
(N)
6.3
0.370
0.290
353
90
Standard/0.76
Standard/0.68
SLAB
SURFACES
Area
Slab
Type
(sf)
HOUSE
Standard
Slab
5975
HVAC SYSTEMS
Minimum Duct
System Type Efficiency Location
HOUSE
Furnace
ACSplit
Tank Type
1 Large
System
1 Large
Duct Tested Duct ACCA Duct
R -value Leakage Manual D Eff
0.780 AFUE Attic R-4.2 No
10.00 SEER Attic R-4.2 No
WATER HEATING SYSTEMS -
Heater Type
Gas
Number
in Energy
Distribution Type System Factor
Recirc/TimeTemp 1 n/a
WATER HEATING SYSTEMS DETAIL
Recovery Rated
Efficiency Input
No 0.743
No 0.596
Tank External
Size Insulation
(gal) R -value
75 R-0
Standby Internal Tank
Loss Insulation Pilot
Fraction R -value Light
0.76 n/a 0.029 R-n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
N
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Water Heating System
COMPUTER METHOD SUMMARY Page 7 C -2R
Project Title.......... SINGLE FAMILY HOME Date..08/23/00 13:05:04
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -FORM C -2R
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
REMARKS
_VAC SIZING
Page 8
HVAC
EProject Title.......... SINGLE'FAMILY HOME Date..08/23/00 13:05:04
$roject Address........ LOT 24, CAHUILLA COURT *******
.A LA QUINTA *v5.10*
Documentation Author... DANA, CEA *******
West Coast Energy Design
7354 Dover Lane
Dublin, CA 94568
925-829-5304
Climate Zone 15
Compliance Method...... MICROPASS v5.10 for 1998 Standards by Enercomp, Inc.
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -HVAC SIZING
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
GENERAL INFORMATION
Building
Permit
Plan
Check Date
Field
Check/ Date
Compliance Method...... MICROPASS v5.10 for 1998 Standards by Enercomp, Inc.
MICROPAS5 v5.10 File -ROSE Wth-CTZ15S92 Program -HVAC SIZING
User#-MP0635 User -West Coast Energy Design Run -COMPLIANCE
GENERAL INFORMATION
Floor Area .................
5975 sf
Volume .....................
72083 cf
Front Orientation..........
Front Facing
128 deg (SE)
Sizing Location............
LA QUINTA
Latitude ...................
33.7 degrees
Winter Outside Design......
30 F
Winter Inside Design.......
70 F
Summer Outside Design......
110 F
Summer Inside Design.......
78 F
Summer Range ...............
28 F
Interior Shading Used......
No
F Exterior Shading Used......
No
Overhang Shading Used......
No
Latent Load Fraction.......
0.20
HEATING AND COOLING
LOAD SUMMARY
Heating
Cooling
Description
(Btuh)
(Btuh)
Opaque Conduction and Solar......
35355
17998
Glazing Conduction ...............
18164
14531
Glazing Solar ....................
n/a
24053
Infiltration .....................
41001
22960
Internal Gain ....................
n/a
3000
Ducts ............................
9452
8254
Sensible Load ....................
103972
90797
Latent Load ......................
n/a
18159
Minimum Total Load
103972
108957
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the -HVAC designer's responsibility to consider all
<� factors when selecting the HVAC equipment.