Loading...
08-0190 (RC) Revision 1 Title 244I` 1 Fr TITLE.24 REPORT Title 24 Report for: JFK Internal Medicine Specialists La Quinta, CA 92253 Project Designer: Robert A. Stephens 1278 Montalvo Way. Palm Springs, CA 92262 (760) 327-7847 Report Prepared By: Robert A. Stephens System Electric Co., Inc. 1278 Montalvo Way Palm Springs, CA 92262 (760) 327-7847 Job Number: Date: 5/7/2008 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT 1VTDeBY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro.4.3 by EnergySoft Job Number: User Number: 5438 i 0 I . TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form LTG -1-C Certificate of Compliance 3 Form LTG -2-C Indoor Lighting Schedule 7 Form LTG -4-C Lighting Controls Credit Worksheet 8 Form LTG -6-C Tailored Method Worksheet 9 Form LTG -MM Lighting Mandatory Measures 11 EnergyPro 4.3 by Energysoft Job Number: User Number: 5438 CERTIFICATE OF COMPLIANCE . (Part 1 of 4) LTG -1 -C jPROJECT NAME JFK Internal Medicine SDecialists _..— DATE 5/7/2008 PROJECT ADDRESS `` La Quintal Portable Lighting Worksheet PRINCIPAL DESIGNER -LIGHTING TELEPHONE Building Kermit #_; ._,. . Robert A. Stephens (760) 327-7847 DOCUMENTATION AUTHOR TELEPHONE A`4:Checked 6y/Date, System Electric Co., Inc. (760) 327-7847 ltnfor6ementAqency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 11/27/07 2,832 Sq.Ft. 15 J (BUILDING TYPE 0 NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUEST ROOM ❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION ❑X ALTERATION METHOD OF LIGHTING ❑ COMPLETE BUILDING ❑ AREA CATEGORY ❑X TAILORED ❑ PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE!- ; ) DATE ; Robert A. Stephens S l� The Principal Lighting Designer hereby certifies that the proposed buildi g design represented in this set of construction doc ments is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 - 132, 146, 148 & 149 of Title 24, Part 6. ❑ The plans & specifications meet the requirements of Part 6 (Sections 10-103a). i ❑ The installation certificates meet the requirements of Part 6 (10-103a 3). j ❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) I❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. i I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am'eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business a Professions Code Sections 5537, 5538 and 6737.1. j PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE: _ LIC. # 5 —� ��.� DATE 0� I Robert A. Stephens �c �,f 7 LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included I ®LTG -1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals XLTG-I-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed WLTG-1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed 'FX LTG -2-C: Indoor Lighting Schedule []LTG -3-C: Portable Lighting Worksheet LTG -4-C: Lighting Controls Credit Worksheet JOLTG-5-C: Indoor Lighting Power Allowance I®LTG-6-C: Tailored Method Worksheet OLTG-7-C: Room Cavity Ratio Worksheet OLTG-8-C: Common Lighting Systems Method Worksheet IOLTG-9-C: Line Voltage Track Lighting Worksheet I En&gyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:3 of 11 to CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 -C PROJECT NAME DATE .JFK Internal Medicine Specialists 5/7/2008 INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) PORTABLE LIGHTING (From LTG -3-C) LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER INSTALLED WATTS 3,217 0 322 2,895 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER- 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) t ALLOWED ❑X AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑X TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 2,958 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ^ ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR. LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCAT (Room #) ' CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc. Check if SPACE CONTROLLED Daylighting NATE TO dFIELD NOTES TO FIELD - For Building Department Use Only ' rT. '+' t�5.1 rz.k skt','� :.,�`r+,_�f 12,5 4 r a+ ' rt �. , X44 } EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: PageA of 11 1 .4 CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1 -C (PROJECT NAME DATE JFK Internal Medicine Specialists 5/7/2008 CONTROLS FOR CREDIT IN CONDITIONED AND UNCONDITIONED SPACES CONTROL LOCATION (Room # or Dwg. #) Waiting Room Waiting Room Waitinq Room Storage Secure Office CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TYPE # OF LUMINAIRES Occ Sensor - <= 250 sqft D 3 Occ Sensor - <= 250 sqft B 6 Occ Sensor - <= 250 sqft C 9 Occ Sensor - <= 250 sqft A 5 Occ Sensor - <= 250 sqft C 1 Occ Sensor - <= 250 sqft Al 1 Occ Sensor - <= 250 sqft B 1 Occ Sensor - <= 250 sqft A3 1 Occ Sensor - <= 250 sqft A2 2 Occ Sensor - <= 250 sqft A3 1 Occ Sensor - <= 250 sqft B 1 Occ Sensor - <= 250 sqft B 1 Occ Sensor - — 250 sqft Al 2 iwIL.j Iv VIGLV -rul oununnj uc LJ421LI I1011t uac vin I EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Paae:5 of 11 I CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG -1-C PROJECT NAME JFK Internal Medicine Specialists DATE 5/7/2008 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: ❑ LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing I EnergvPro 4.3 by EnergvSoft User Number: 5438 Job Number: Paoe:6 of 11 1 I ef, INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C !PROJECT NAME : DATE JFK Internal Medicine Specialists 5/7/2008 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES j Luminaire Lamps/Ballasts Installed Watts C D E F G H _ I i J Name Type Description -0 CD r- 'vc "'NQ � N (D O 3( N cv� �NQ 0 fD q O I- =3 0) N N mm C n 'J :1 -, X;�d T v N (D m 1 ; N a Yes No A (2) 2 ft U -Tube T8 Elec FB3lT8/F32T8U 2 32 1.01 62.0 X I 18 —; 1,116' Al 3) 4 ft Fluorescent T8 Energy Savings lec =,32T8 3 30 1.0 79.0 X 111 869 A2 2) 4 ft Fluorescent T8 Energy Savings ec 32T8 3 30 1.0 79.0 X 2 1581 A3�3e4 ft Fluorescent T8 Energy Savings 32T8 3 301 1.0 79.0 X 2 158 B I (1) 26w Compact Fluorescent Triple 4 Pi Elec :;,Ej 26W/GX24q-3 1 26 1.01 28.0 X ' 13 3641 C 35w Low Voltage Halogen 5–W 1 X 1 101--- 380.; D 35w Low Voltage Halogen 35 Watt Lamp 1 35 1.0 38.0 X 3I 11_4_ F (1) 4 ft Fluorescent T8 Energy Savings Elec F32T8 1 30 1 29.0-K 21 581 I i I I i I I I I i I PAGE TOTAL 1 3,217 BUILDING TOTAL (sum of all pages) 3,21'7 'PORTABLE LIGHTING (From LTG -3-C) E==O CONTROL CREDIT (From LTG -4-C) ! 322 ADJUSTED ACTUAL WATTS 2,895 EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:7 of 11 j IGHTING CONTROLS CREDIT WORKSHEET NTROL CREDITS FOR CONDITIONED SPACES PROJECT NAME JFK Internal Medicine Special Part 1 of 2 DATE LTG -4-C (7/2008 A B C D E F G H ; I J ROOM # ZONF- ID CONDITIONED AREAS I LIGHTING I CONTROL I DESCRIPTION PLAN REF. ROOM AREA (SF) DAYLIGHTING CONTROL WATTS OF ; LIGHTING ' CREDIT CONTROL ADJUST. i WATTS LIGHTING FACTOR' ; (H X 1) WINDOW WALL RATIO GLAZING VLT SKYLIGHT EFFECTIVE APERTURE' Waiting Room Occ Sensor-sgft<-250 D 480 114 0.201 231 i Waiting Room Occ Sensor-<- 250 sqft B 480 168 0.20 34 � Waiting Room Occ Sensor - <= 250 s ft C 480 342 0.20 i 68 Reception Occ Sensor - — 25o A 352 310 0.201 62 Reception Occ Sensor-sgft<-8 C 352 38 0.20 8 Lab Occ Sensor <= 250 Al 60 79 0.20 16� Storage Secure Occ Sensor - <= 250 sgft B 20 28 0.201 6 f Storage General Occ Sensor <= 250 A3 401 79 0.201 161 Lounge Occ sensgftr - <- 250 A2 144 158 Office Manager Occ Se s ft <-250 A3 100 79 0.20 161. Data / Utility Occ Sensor- <= 250 B 36 28 0.20 6 Storage Occ Sens ft <= 250 B 16 28. 0.20 6 Workrom Occ Sensor 250 ft Al 264 158 0.20 3Doose I I � i I 1 I I � . ' I 1) From Equation 146-A 2) From Table 146-A PAGE TOTAL 3221 BUILDING TOTAL 322 Enter in LTG -2-C: Lighting Control Credit I EnergyPro 4.3 by EnergvSoft User Number: 5438 Job Number: Paw of 11 i TAILORED METHOD WORKSHEET (Part 1 of 3) LTG -6-C PROJECT NAME IDATE JFK Internal Medicine Specialists I 5/7/2008 11. Watts for Illuminance Categories (from Tailored LPD Total below) 2,9581 Watts' ;1 j2. Watts for Display Lighting 0+ 0+ 0+ 0= Q Watts; Wall Display Floor Display Ornamental/Special Very Valuable Display ! i Effects Display ! ' 14. Total Allowed Watts (lines 1+2) TAILORED LPD - Illuminance Categories From Table 146-D I I ! I 2,9581 Watts t-xam o I mean care Patients• rims - Reading D 6.86 0 ❑ 901 _ 1-'.2011.-108' I A B C D E F G i Exam 7 TASK/ACTIVITY D ROOM RCR From 901 1.201 ALLOWED ROOM or ILLUMINANCE CAVITY LTG -7 FLOOR ALLOWED WATTS NAME NON -TASK AREA CATEGORY RATIO Y N AREA LPD (E x F) Waiting Room waiting Area C 3.59 1� ❑ 4321 0:80 346 Reception Lobby, Main Entry C 3.14 ❑ 0 352 0.60 211 Exam 1 Health Care Patients' Rms - Reading D 6.86 ❑ 90 1.20 1081 Exam 2 Health Care ding nts' Rms - D 6.86 O ❑ 90 1.20 108 Exam 3 Health CaRe dani9nts' Rms D 6.86 ER ❑ 90 1.20 108 Exam 4 Health Care Patients' Rms - Reading D 6.86 O ❑ 90 1.20 108 Lab Health Care Labs - Specimen Collecting E 8.671 EA ❑ 60 2.50 150 t-xam o I mean care Patients• rims - Reading D 6.86 0 ❑ 901 _ 1-'.2011.-108' I 108 Exam 6 Health Care Patients' Rms - Reading D 6.86 2 ❑ 90111.20' i Exam 7 Health Care Patients' Rms - Reading D 6.86 O ❑ 901 1.201 _ 1081 ! Exam 8 Health Care Patients' Rms - Reading D 1 6.861 0 ❑ 90 1.201 I 1081 Storage Secure Health Care_Utility Rm D 14.62 � El 20 1.40 i I 28 Storage General Health Care -Utility Rm D 10.56 2 ❑ 40 1.40 56 Lounge General & Offices_es C 5.42 2 ❑ 144 0.80 115, Office Manager Offices_ Handwritten - #3 Pencil E 6.501 0 ❑ 100 1.80 180: Restrooms Health Care Toilets C 9.10 ❑X ❑ 100 1.10 _ 1101 Data /utility i Health Care Utility Rm D 10.83 E ❑ 36 1.40 50 • i Storage Health Care Utility Rm D 16.25 FX1 ❑ 16 1.40 Doctor / Nurse Workroom Health Care -Nursing Stns.- Desk E 3.941 ❑x ❑ 264 _ _ _ 475; _ PAGE TOTAL 4 1 _ - 2608 - 608:BUILDING BUILDING TOTAL I 2,832 21958: FT 2 WATTS EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:9 of 11 .d TAILORED METHOD WORKSHEET (Part 1 of 3) LTG -6-C PROJECT NAME DATE j JFK Internal Medicine Specialists i 5/7/2008 TAILORED LPD SUMMARY Separate Tailored Method Worksheets must be filled out for conditioned and unconditioned spaces. i � 11. Watts for Illuminance Categories (from Tailored LPD Total below) ; 2,9581 watts' ' 12. Watts for Display Lighting 0+ p+ 0+ 0= 0 watts Wall Display Floor Display Ornamental/Special Very Valuable Display Effects Display 4. Total Allowed Watts (lines 1+2) ! 2,958 Watts TAILORED LPD - Illuminance Categories From Table 146-D A B C D E F G j TASK/ACTIVITY ROOM RCR From ALLOWED ROOM or ILLUMINANCE CAVITY LTG -7 FLOOR ALLOWED WATTS NAME NON -TASK AREA CATEGORY RATIO Y N AREA LPD (E x F) Hallways Offices—General - Hallways B 13.00 1Z ❑ 500 0.70 350: ❑ ❑ ❑ ❑ i ❑ ❑ ❑ ❑ ❑ ❑ � ❑ ❑ II I 00 -� -- - El 0 J ❑❑I El El El ❑ ❑ ❑ ❑ - ❑ ❑ —� 110 ! ❑ ❑ I_ I ! PAGE TOTAL 500 �_ 350: BUILDING TOTAL 2,$32 2,958 FT' WATTS EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:10 of 11 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME DATE JFK Internal Medicine Specialists 5/7/2008 DESCRIPTION Desiginer Enforcement ❑X §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device�.� �~ capable of automatically shutting off the lighting. ? X❑ §131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area,� j of override is not to exceed 5,000 square feet. X] §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the / manufacturer. y 0 §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. 0 §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are ; 9A - specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. f X] §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to- ceiling walls. a§131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be� controlled with bi-level switching for uniform reduction of lighting within the room. X❑ §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall . have 50% of the lamps in each daylit area controlled by a separate switch; or theGj effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. ® §131(e) Display Lighting. Display lighting shall be separately switched on circuits that c),� are 20 amps or less. EnergyPro 4.3 by EnergySoft User Number: 54W Job Number: Page:11 of 11