08-0192 (RC) Revision 1 Title 24� MAY 13-2008
2U08 D
TITLE 24 REPORT
Title 24 Report for:
JFK Orthopedic Center
La Quinta, CA 92253
Project Designer:
Robert A. Stephens
1278 Montalvo Way
Palm Springs, CA 92262
(760) 327-7847
Report Prepared By:
Robert A. Stephens
System Electric Co., Inc.
1278 Montalvo Way
Palm Springs, CA 92262
(760) 327-7847
Job Number:
Date:
5/7/2008
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE b IWO BY
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report: This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.3 by EnergySoft Job Number: User Number: 5438
t+l
TABLE OF CONTENTS
Cover Page
Table of Contents
Form LTG -1-C Certificate of Compliance
Form LTG -2-C Indoor Lighting Schedule
Form LTG -4-C Lighting Controls Credit Worksheet
Form LTG -6-C Tailored Method Worksheet
Form LTG -MM Lighting Mandatory Measures
r
1
2
3
7
8
9
11
i
EnergyPro 4.3 by EnergySoft Job Number: User Number: 5438
1 4
CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C
PROJECT NAME 1 DATE
JFK OrthoDedic Center 5/7/2008
PROJECT ADDRESS
La Quinta
:PRINCIPAL DESIGNER - LIGHTING
! TELEPHONE - Building :Permit #
Robert A. Stephens
(760) 327-7847
DOCUMENTATION AUTHOR
_
TELEPHONE .cnebkeaby/Date
I
System Electric Co., Inc.
1
760 327-7847 I :- • Enforcement Agency Use,
GENERAL INFORMATION
DATE OF PLANS
BUILDING CONDITIONED FLOOR AREA
CLIMATE ZONE
03/24/08
4,669 Sq.Ft.
15
BUILDING TYPE a NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM
❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS
PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION ALTERATION
METHOD OF LIGHTING ❑ COMPLETE BUILDING ❑ AREA CATEGORY TAILORED F-] PERFORMANCE
COMPLIANCE ❑ COMMON LIGHTING
i
[S ATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, •:
Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements.
!The documentation preparer hereby certifies that the documentation is aLlzcurate and complete.
DOCUMENTATION AUTHOR
Robert A. Stephens
SIGNATURE DATE
c
!The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction documents
is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with i
this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 1
130 -.132, 146, 148 & 149 of Title 24, Part 6. i
The plans & specifications meet the requirements of Part 6 (Sections 10-103a).
❑ The installation certificates meet the requirements of Part 6 (10-103a 3). j
❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). i
i
Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.)
!
.❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person
responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect.
I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document I
\.as the person responsible for its preparation; and that I am a licensed contractor performing this work.
I
I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a
structure or type of work described as exempt pursuant to Business and P ssions Code Sections 5537, 5538 and 6737.1. 1
PRINCIPAL LIGHTING DESIGNER -NAME SIGNATURE DATE LIC. #
-
���
Robert A. Stephens G ,�) !� %C'>
LIGHTING MANDATORY MEASURES
Indicate location on plans of Note Block for Mandatory Measures
GHTING COMPLIANCE
®LTG -1-C, Parts 1 of 4 and 2 of 4:
Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals j
XLTG-1-C, Part 3 of 4:
Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed i
IRLTG-1-C, Part 4 of 4:
Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed I
Gia LTG -2-C:
Indoor Lighting Schedule
❑LTG -3-C:
Portable Lighting Worksheet
®LTG -4-C:
Lighting Controls Credit Worksheet
❑LTG -5-C:
Indoor Lighting Power Allowance
IR LTG -6-C:
Tailored Method Worksheet
❑LTG -7-C:
Room Cavity Ratio Worksheet
❑LTG -8-C:
Common Lighting Systems Method Worksheet 1
❑LTG -9-C:
Line Voltage Track Lighting Worksheet
EnergyPro 4.3 by EnergySoft
User Number: 5438 Job Number: Page:3 of 11
C
CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 -C
PROJECT NAME DATE
JFK Orthopedic Center 5/7/2008
INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES
INSTALLED
WATTS
INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 3,547
PORTABLE LIGHTING (From LTG -3-C) 0
LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 107
CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 3,440
INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0
LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0
UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0
ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES
❑ COMPLETE BUILDING METHOD (From LTG -5-C)
ALLOWED
❑X AREA CATEGORY METHOD (From LTG -5-C)
WATTS
❑X TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER
5 076
ALTERNATE COMPLIANCE
❑ PERFORMANCE METHOD
❑ COMMMON LIGHTING SYSTEM (From LTG -8-C)
ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C)
0
MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS 771
CONTROL LOCA'
(Room #)
CONTROL
IDENTIFICATION
CONTROL TYPE
(Auto Time Switch, Dimmin
SPACE CONTROLLED
Check if
'NOTE TO
I v
CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1 -C
PROJECT NAME DATE
JFK Orthopedic Center 5/7/2008
CONTROLS FOR CREDIT IN CONDITIONED AND UNCONDITIONED SPACES
CONTROL LOCATION CONTROL
(Room # or Dwg. #) IDENTIFICATION
Lounge
I.T.Room
Janitor 126
Storage 122
Storage 123
Storage 128
Dictation 129
Dictation 113
Storage 114
CONTROL TYPE -
(Occupant, Daylight, Dimming, etc.)
Occ Sensor - <= 250 sqft
Occ Sensor - <= 250 sqft
Occ Sensor - <= 250 sqft
Occ Sensor - — 250 sqft
Occ Sensor - <= 250 sqft
Occ Sensor - <= 250 sqft
Occ Sensor - <= 250 sqft
Occ Sensor - <= 250 sqft
Or.r. Sensnr - <= 750 snft
CONTROLLEDLU INAIRES
TYPE
OF LUMINAIRES
A2
2
B
1
B
1
A3
1
B
1
A3
1
B
1
B
1
A3
1
NOTE TO
FIELD
r
J
EnergvPro 4.3 by EnergvSoft User Number: 5438 Job Number: Page:5 of 11
CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG-1 -C
PROJECT NAME
JFK Orthopedic Center
DATE
5/7/2008
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance
tests for lighting systems. The designer is required to check the boxes by all acceptance tests that
apply and list all equipment that require an acceptance test. If all equipment of a certain type requires
a test, list the equipment description and the number of systems to be tested in parentheses. The NJ
number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the
test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design
professional or an agent selected by the owner). Since this form will be part of the plans, completion
of this section will allow the responsible party to budget for the scope of work appropriately.
Building Departments:
Before an occupancy permit is granted for a newly constructed building or space, or a new lighting
system system serving a building or space is operated for normal use, all control devices serving the
building or space shall be certified as meeting the Acceptance Requirements for Code Compliance.
In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department
that:
A. Certifies plans, specifications, installation certificates, and operating and maintenance
information meet the requirements of§ 10-103(b) and Title 24 Part 6.
Test Description
Test Performed By:
❑ LTG-2-A: Lighting Control Acceptance Document
- Occupancy Sensor Acceptance
- Manual Daylight Controls Acceptance
- Automatic Time Switch Control Acceptance
Equipment requiring acceptance testing
❑ LTG-3-A: Automatic Daylighting Controls Acceptance Document
Equipment requiring acceptance testing
I EneravPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:6 of 11 1
INDOOR LIGHTING SCHEDULE '(Part 1 of 2) LTG -2-C
A3
3) 4 ft Fluorescent T8 Energy Savings
lec
z32T8
3
30'
1.0
79.0
X
!PROJECT NAME
JFK Orthopedic Center
6
474
6
�1lec6w Compact Fluorescent Triple 4 Pi
DATE
5/7/2008
1
26
1.0
28.0
X
50
1 400
INSTALLED LIGHTING POWER FOR CONDITIONED SPACES
(1) 4 ft Fluorescent T8 Energy Savings
Elec
F32T8
1
30
' 1.0
29.0
X
4
1.161
Luminaire
Lamps/Ballasts
Installed
Watts'
I
C
D
E
F
G
H
I
_
J
IName
Type Description
�r
�3c
3
CoQ
r
�,�
and
cd�
3.d 3
��Q
c
C�
:3'
N
pc)
mm
=
r I
3 c i_
I i ���
=� �N
i
N
xdm
Al
(3) 4 ft Fluorescent T8 Energy Savings
Elec
F32T8
3
30
1.0
79.0
X
15' ..___
_ 1,185
A2
V) 4 ft Fluorescent T8 Energy Savings
04070
1�
inl
1 ni
79 fl
X
I
I Q
I
�1 1 F
A3
3) 4 ft Fluorescent T8 Energy Savings
lec
z32T8
3
30'
1.0
79.0
X
6
474
6
�1lec6w Compact Fluorescent Triple 4 Pi
CFTR26W/GX24 -3
1
26
1.0
28.0
X
50
1 400
F
(1) 4 ft Fluorescent T8 Energy Savings
Elec
F32T8
1
30
' 1.0
29.0
X
4
1.161
PAGE TOTAL L 3,547;
BUILDING TOTAL (sum of all pages) 3,547;
PORTABLE LIGHTING (From LTG -3-C) I V
CONTROL CREDIT (From LTG -4-C) _ 10T
ADJUSTED ACTUAL WATTS 3 440;
EnergyPro 4.3 by Energysoft User Number: 5438 Job Number: Page:7 of 11
_IGHTING CONTROLS CREDIT WORKSHEET (Part -1 of 2) LTG -4-C
(CONTROL CREDITS FOR CONDITIONED SPACES
(PROJECT NAME
DATE
5/7/2008
A
B
C
D
E F G
H
I J
j ROOM #
ZONE ID
CONDITIONED
AREAS
LIGHTING
CONTROL
DESCRIPTION
PLAN
REF.
ROOM
AREA
(SF)
DAYLIGHTING
WATTS OF
CONTROL
LIGHTING
LIGHTING
ADJUST.
FACTOR'
CONTROL,
CREDIT
WATTS
(H X I)
WINDOW
WALL
RATIO
GLAZING
VLT
SKYLIGHT
EFFECTIVE
APERTURE'
Lounge
Occ Sensor - <= 250
sgft
A2
1891
1581
0.201
321
_
I.T.Room
Occ Sensor - <= 250
sgft
i B
32
—t
I
I 28
0.201
6
_
Janitor 126
Occ Sensor - <= 250
sgft
B
40
_
281
_
0.20 6
Storage 122
i
Occ Sensor - <= 250 sft
A3
80
791
0.20 16
Storage 123
Occ Sensor - — 250
sqft
B
25
28
0.20.
_
6
Storage 128
Occ Se s ft <-250
A3
50
79
0.20
16
Dictation 129
Occ Sensor - <= 250
sgft
B
36
28
0.20
6
Dictation 113
Occ Sensor -<= 250
sft
B
36
28
0.20
6
Storage 114
Occ Sensor - <= 250
sft
A3�
70
79
0.20
_
16'
I
I
I
i
I
i
i
.i
i
i
PAGE TOTAL 107
1) From Equation 146-A ----
2) From Table 146-A BUILDING TOTAL
L___ 107_
Enter in LTG -2-C: Lighting Control Credit
I EneravPro 4.3 by EneravSoft User Number: 5438 Job Number: Page:8 of 11
�AILORED METHOD WORKSHEET (Part 1 of 3) LTG -
(PROJECT NAME
JFK Orthopedic Center
DATE
5/7/2008
TAILORED LPD SUMMARY Separate Tailored Method Worksheets must be filled out for conditioned'and unconditioned spaces.
1. Watts for Illuminance Categories (from Tailored LPD Total below)
-- 5- -- -�,0761 watts
I
2. Watts for Display Lighting
it
0+ 0+ 0+ 0= 0 Watts
Wall Display Floor Display Ornamental/Special Very Valuable Display I i
Effects Display j
4. Total Allowed Watts (lines 1+2)
IF 5,0761 watts
PAGE TOTAL 2 550 6
BUILDING TOTAL 9 ........._.5,076,
FT 2 WATTS
EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:9 of 11
A
B
C
D
E
F
G
TASK/ACTIVITY
ROOM
RCR From
ALLOWED
ROOM
or
ILLUMINANCE
CAVITY
LTG -7
FLOOR
ALLOWED
WATTS
NAME
NON -TASK AREA
CATEGORY
RATIO
Y N
AREA
LPD
(E x F)
Reception
Health Care Waiting Areas -
General
C
3:01
❑ 9
761
0.60
457;
Exam 1
Health Care _din Patients' Rms -
Rea
D
6.20
0 ❑
110
1.20
132
Exam 2
Health CarePatients'nts' Rms -
D
6.20
❑x ❑
110
1.20
132
Business Office 103
Offices -Handwritten - #3 Pencil
E
6.20
❑
110
1.80
198
Exam 4
Health Care Patients' Rms -
Reading
D
6.20
❑x ❑
110
1.20
132;
Exam 5
Patients' Rms -
Health Care Pati
Readin
D
6.20
x
❑ ❑
110
1.20
132
Workroom 108
Health Care -Med Records
E
4.68
O ❑
198
1.80
356
Exam 6
Health Care Patients' Rms -
Reading
D
6.20
D9❑
110
1.20
132'
Exam 7
-_
Health Care' Patients' Rms -
Reading
D
6.20
[A ❑
110
1.20
132{
Exam 8
Health Care Patients' Rms -
Reading
D
6.20
[A ❑
110
1.20
_
132_
Exam 9
Health Care Patients' Rms - ding
D
6.20
❑ ❑
110
1.201!'
132
Exam 10
i
Health Care Patients' Rms -
Reading
D
6.20
❑X ❑
110
1.20
13_2'
Lounge
Offices _GLoungesLobbies &
C
4.73
0 ❑
189
0.80
1511
Shower 121
Health Care -Locker Rms
C
9.75
IX ❑
50
1.10
55
I.T.Room
Health Care_Utility Rm
D
12.19
D ❑
321
1.401
4
j Janitor 126
Offices -General - Janitorial
C
10.56
❑
40
1.10
44
j Restroom 125
Health Care -Toilets
C
9.75
1Z ❑
50
1.10
55]
Restroom 124
Health Care -Toilets
C
9.75
ER ❑
50
1.10
Storage 122
Health Care -Utility Rm
D
7.31
0 El
_
112
PAGE TOTAL 2 550 6
BUILDING TOTAL 9 ........._.5,076,
FT 2 WATTS
EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:9 of 11
i
TAILORED METHOD WORKSHEET (Part 1 of 3) LTG -6-C
(PROJECT NAME I DATE
JFK Orthopedic Center I 5/7/2008
TAILORED LPD SUMMARY Separate Tailored Method Worksheets must be filled out for conditioned and unconditioned spaces.
from Categories 11. Watts for Illuminance Cate Tailored LPD Total below 1
t g ( ) 5,0761 watts:
2. Watts for Display Lighting
0 0+ 0 +0 _- .01 watts
Wall Display Floor Display Ornamental/Special Very Valuable Display
Effects Display
4. Total Allowed Watts (lines 1+2) �5, 761 Watts! 1
TAILORED LPD - Illuminance Categories From Table 146-D
A
B
C
D
E
F
G
1
TASK/ACTIVITY
ROOM
RCR From
ALLOWED
ROOM
or
ILLUMINANCE
CAVITY
LTG -7
FLOOR
ALLOWED
WATTS
NAME
NON -TASK AREA
CATEGORY
RATIO
Y N
AREA
LPD
(E x F)
Storage 123
Health Care_Utility Rm
D
13.00
D9 ❑
25
1.40
351
Storage 128
Health Care_Utility Rm
D
9.75
❑
50
1.40
70_1
X -Ray 133
Radiatioln Therapy Isotope Kitchn
- p
E
4.49
M ❑
210
1.80
378 -
Dressing
Dressing / Waiting
Health Care VMINfM Areas - Loc
Or Reading
I
D
5.42
0 ❑
150
1.20
180'
Dictation 129
Health Care—Med Records
E
10.83
1� ❑
36
2.50
90
Nurse Station
Health Care neral ing Stns -
D
5.75
2 ❑
130
1.20
156
Restroom 111
I
Health Care Toilets
-
C
8.71
0 ❑
56
1.10
62
Restroom 112
Health Care Toilets
C
8.71
❑
56,
1.101
62'
Dictation 113
I Health Care—Med Records
E
10.83
X
36!
2.501'
90.
Storage 114
Health Care_Utility Rm
D
80.09
O ❑
70
1.40
F - --
98;1
Nursing Station
Health Care—Nursing Stns - Desk
E
6.50
E ❑
100
1.80
180
Hallways
Health Care _Corridor - Nursing -
C
6.64
9 ❑
1,200
0.80
960
El El
El E]
❑ ❑
El El
El El
El El
11 El
PAGE TOTAL 2,1191 2,360
BUILDING TOTAL 4,669] _ 5,076
FTs WATTS
EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:10 of 11
LIGHTING MANDATORY MEASURES LTG -MM
PROJECT NAME DATE
JFK Orthopedic Center I
5/7/2008
DESCRIPTION
Designer
Enforcement
0 §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic
control to shut off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or other device
capable of automatically shutting off the lighting.
}
)
0 §131(d)2Override for Building Lighting Shut-off: The automatic building shut-off system is
provided with a manual, accessible override switch in sight of the lights. The area
of override is not to exceed 5,000 square feet.
l rr
✓
RX §119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified and installed as directed by the
manufacturer.
5111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for
the project are certified and listed in, the Directory. All installed fixtures shall. be
certified.
0 §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three
lamp fluorescent fixtures are tandem wired with two lamp ballasts where required
by Standards Section 132; or all one and three lamp fluorescent fixtures are
specified with electronic high -frequency ballasts and are exempt from tandem
wiring requirements.
LnL /J
X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped
with a separate switch or occupancy sensor device for each area with floor -to-
ceiling walls.
§131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
�l
controlled with bi-level switching for uniform reduction of lighting within the room.
§131(c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 square feet and that allow for the effective use of daylight in the area shall
have 50% of the lamps in each daylit area controlled by a separate switch; or the
effective use of daylight cannot be accomplished because the windows are
continuously shaded by a building on the adjacent lot. Diagram of shading during
different times of the year is included on plans.
® §131(e) Display Lighting. Display lighting shall be separately switched on circuits that
are 20 amps or less.
EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page: 11 of 11