Loading...
08-0192 (RC) Revision 1 Title 24� MAY 13-2008 2U08 D TITLE 24 REPORT Title 24 Report for: JFK Orthopedic Center La Quinta, CA 92253 Project Designer: Robert A. Stephens 1278 Montalvo Way Palm Springs, CA 92262 (760) 327-7847 Report Prepared By: Robert A. Stephens System Electric Co., Inc. 1278 Montalvo Way Palm Springs, CA 92262 (760) 327-7847 Job Number: Date: 5/7/2008 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE b IWO BY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report: This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 5438 t+l TABLE OF CONTENTS Cover Page Table of Contents Form LTG -1-C Certificate of Compliance Form LTG -2-C Indoor Lighting Schedule Form LTG -4-C Lighting Controls Credit Worksheet Form LTG -6-C Tailored Method Worksheet Form LTG -MM Lighting Mandatory Measures r 1 2 3 7 8 9 11 i EnergyPro 4.3 by EnergySoft Job Number: User Number: 5438 1 4 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C PROJECT NAME 1 DATE JFK OrthoDedic Center 5/7/2008 PROJECT ADDRESS La Quinta :PRINCIPAL DESIGNER - LIGHTING ! TELEPHONE - Building :Permit # Robert A. Stephens (760) 327-7847 DOCUMENTATION AUTHOR _ TELEPHONE .cnebkeaby/Date I System Electric Co., Inc. 1 760 327-7847 I :- • Enforcement Agency Use, GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 03/24/08 4,669 Sq.Ft. 15 BUILDING TYPE a NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM ❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION ALTERATION METHOD OF LIGHTING ❑ COMPLETE BUILDING ❑ AREA CATEGORY TAILORED F-] PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING i [S ATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, •: Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. !The documentation preparer hereby certifies that the documentation is aLlzcurate and complete. DOCUMENTATION AUTHOR Robert A. Stephens SIGNATURE DATE c !The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with i this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 1 130 -.132, 146, 148 & 149 of Title 24, Part 6. i The plans & specifications meet the requirements of Part 6 (Sections 10-103a). ❑ The installation certificates meet the requirements of Part 6 (10-103a 3). j ❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). i i Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ! .❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document I \.as the person responsible for its preparation; and that I am a licensed contractor performing this work. I I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and P ssions Code Sections 5537, 5538 and 6737.1. 1 PRINCIPAL LIGHTING DESIGNER -NAME SIGNATURE DATE LIC. # - ��� Robert A. Stephens G ,�) !� %C'> LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures GHTING COMPLIANCE ®LTG -1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals j XLTG-1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed i IRLTG-1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed I Gia LTG -2-C: Indoor Lighting Schedule ❑LTG -3-C: Portable Lighting Worksheet ®LTG -4-C: Lighting Controls Credit Worksheet ❑LTG -5-C: Indoor Lighting Power Allowance IR LTG -6-C: Tailored Method Worksheet ❑LTG -7-C: Room Cavity Ratio Worksheet ❑LTG -8-C: Common Lighting Systems Method Worksheet 1 ❑LTG -9-C: Line Voltage Track Lighting Worksheet EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:3 of 11 C CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 -C PROJECT NAME DATE JFK Orthopedic Center 5/7/2008 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 3,547 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 107 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 3,440 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑X AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑X TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 5 076 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS 771 CONTROL LOCA' (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimmin SPACE CONTROLLED Check if 'NOTE TO I v CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1 -C PROJECT NAME DATE JFK Orthopedic Center 5/7/2008 CONTROLS FOR CREDIT IN CONDITIONED AND UNCONDITIONED SPACES CONTROL LOCATION CONTROL (Room # or Dwg. #) IDENTIFICATION Lounge I.T.Room Janitor 126 Storage 122 Storage 123 Storage 128 Dictation 129 Dictation 113 Storage 114 CONTROL TYPE - (Occupant, Daylight, Dimming, etc.) Occ Sensor - <= 250 sqft Occ Sensor - <= 250 sqft Occ Sensor - <= 250 sqft Occ Sensor - — 250 sqft Occ Sensor - <= 250 sqft Occ Sensor - <= 250 sqft Occ Sensor - <= 250 sqft Occ Sensor - <= 250 sqft Or.r. Sensnr - <= 750 snft CONTROLLEDLU INAIRES TYPE OF LUMINAIRES A2 2 B 1 B 1 A3 1 B 1 A3 1 B 1 B 1 A3 1 NOTE TO FIELD r J EnergvPro 4.3 by EnergvSoft User Number: 5438 Job Number: Page:5 of 11 CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG-1 -C PROJECT NAME JFK Orthopedic Center DATE 5/7/2008 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: ❑ LTG-2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG-3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing I EneravPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:6 of 11 1 INDOOR LIGHTING SCHEDULE '(Part 1 of 2) LTG -2-C A3 3) 4 ft Fluorescent T8 Energy Savings lec z32T8 3 30' 1.0 79.0 X !PROJECT NAME JFK Orthopedic Center 6 474 6 �1lec6w Compact Fluorescent Triple 4 Pi DATE 5/7/2008 1 26 1.0 28.0 X 50 1 400 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES (1) 4 ft Fluorescent T8 Energy Savings Elec F32T8 1 30 ' 1.0 29.0 X 4 1.161 Luminaire Lamps/Ballasts Installed Watts' I C D E F G H I _ J IName Type Description �r �3c 3 CoQ r �,� and cd� 3.d 3 ��Q c C� :3' N pc) mm = r I 3 c i_ I i ��� =� �N i N xdm Al (3) 4 ft Fluorescent T8 Energy Savings Elec F32T8 3 30 1.0 79.0 X 15' ..___ _ 1,185 A2 V) 4 ft Fluorescent T8 Energy Savings 04070 1� inl 1 ni 79 fl X I I Q I �1 1 F A3 3) 4 ft Fluorescent T8 Energy Savings lec z32T8 3 30' 1.0 79.0 X 6 474 6 �1lec6w Compact Fluorescent Triple 4 Pi CFTR26W/GX24 -3 1 26 1.0 28.0 X 50 1 400 F (1) 4 ft Fluorescent T8 Energy Savings Elec F32T8 1 30 ' 1.0 29.0 X 4 1.161 PAGE TOTAL L 3,547; BUILDING TOTAL (sum of all pages) 3,547; PORTABLE LIGHTING (From LTG -3-C) I V CONTROL CREDIT (From LTG -4-C) _ 10T ADJUSTED ACTUAL WATTS 3 440; EnergyPro 4.3 by Energysoft User Number: 5438 Job Number: Page:7 of 11 _IGHTING CONTROLS CREDIT WORKSHEET (Part -1 of 2) LTG -4-C (CONTROL CREDITS FOR CONDITIONED SPACES (PROJECT NAME DATE 5/7/2008 A B C D E F G H I J j ROOM # ZONE ID CONDITIONED AREAS LIGHTING CONTROL DESCRIPTION PLAN REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR' CONTROL, CREDIT WATTS (H X I) WINDOW WALL RATIO GLAZING VLT SKYLIGHT EFFECTIVE APERTURE' Lounge Occ Sensor - <= 250 sgft A2 1891 1581 0.201 321 _ I.T.Room Occ Sensor - <= 250 sgft i B 32 —t I I 28 0.201 6 _ Janitor 126 Occ Sensor - <= 250 sgft B 40 _ 281 _ 0.20 6 Storage 122 i Occ Sensor - <= 250 sft A3 80 791 0.20 16 Storage 123 Occ Sensor - — 250 sqft B 25 28 0.20. _ 6 Storage 128 Occ Se s ft <-250 A3 50 79 0.20 16 Dictation 129 Occ Sensor - <= 250 sgft B 36 28 0.20 6 Dictation 113 Occ Sensor -<= 250 sft B 36 28 0.20 6 Storage 114 Occ Sensor - <= 250 sft A3� 70 79 0.20 _ 16' I I I i I i i .i i i PAGE TOTAL 107 1) From Equation 146-A ---- 2) From Table 146-A BUILDING TOTAL L___ 107_ Enter in LTG -2-C: Lighting Control Credit I EneravPro 4.3 by EneravSoft User Number: 5438 Job Number: Page:8 of 11 �AILORED METHOD WORKSHEET (Part 1 of 3) LTG - (PROJECT NAME JFK Orthopedic Center DATE 5/7/2008 TAILORED LPD SUMMARY Separate Tailored Method Worksheets must be filled out for conditioned'and unconditioned spaces. 1. Watts for Illuminance Categories (from Tailored LPD Total below) -- 5- -- -�,0761 watts I 2. Watts for Display Lighting it 0+ 0+ 0+ 0= 0 Watts Wall Display Floor Display Ornamental/Special Very Valuable Display I i Effects Display j 4. Total Allowed Watts (lines 1+2) IF 5,0761 watts PAGE TOTAL 2 550 6 BUILDING TOTAL 9 ........._.5,076, FT 2 WATTS EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:9 of 11 A B C D E F G TASK/ACTIVITY ROOM RCR From ALLOWED ROOM or ILLUMINANCE CAVITY LTG -7 FLOOR ALLOWED WATTS NAME NON -TASK AREA CATEGORY RATIO Y N AREA LPD (E x F) Reception Health Care Waiting Areas - General C 3:01 ❑ 9 761 0.60 457; Exam 1 Health Care _din Patients' Rms - Rea D 6.20 0 ❑ 110 1.20 132 Exam 2 Health CarePatients'nts' Rms - D 6.20 ❑x ❑ 110 1.20 132 Business Office 103 Offices -Handwritten - #3 Pencil E 6.20 ❑ 110 1.80 198 Exam 4 Health Care Patients' Rms - Reading D 6.20 ❑x ❑ 110 1.20 132; Exam 5 Patients' Rms - Health Care Pati Readin D 6.20 x ❑ ❑ 110 1.20 132 Workroom 108 Health Care -Med Records E 4.68 O ❑ 198 1.80 356 Exam 6 Health Care Patients' Rms - Reading D 6.20 D9❑ 110 1.20 132' Exam 7 -_ Health Care' Patients' Rms - Reading D 6.20 [A ❑ 110 1.20 132{ Exam 8 Health Care Patients' Rms - Reading D 6.20 [A ❑ 110 1.20 _ 132_ Exam 9 Health Care Patients' Rms - ding D 6.20 ❑ ❑ 110 1.201!' 132 Exam 10 i Health Care Patients' Rms - Reading D 6.20 ❑X ❑ 110 1.20 13_2' Lounge Offices _GLoungesLobbies & C 4.73 0 ❑ 189 0.80 1511 Shower 121 Health Care -Locker Rms C 9.75 IX ❑ 50 1.10 55 I.T.Room Health Care_Utility Rm D 12.19 D ❑ 321 1.401 4 j Janitor 126 Offices -General - Janitorial C 10.56 ❑ 40 1.10 44 j Restroom 125 Health Care -Toilets C 9.75 1Z ❑ 50 1.10 55] Restroom 124 Health Care -Toilets C 9.75 ER ❑ 50 1.10 Storage 122 Health Care -Utility Rm D 7.31 0 El _ 112 PAGE TOTAL 2 550 6 BUILDING TOTAL 9 ........._.5,076, FT 2 WATTS EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:9 of 11 i TAILORED METHOD WORKSHEET (Part 1 of 3) LTG -6-C (PROJECT NAME I DATE JFK Orthopedic Center I 5/7/2008 TAILORED LPD SUMMARY Separate Tailored Method Worksheets must be filled out for conditioned and unconditioned spaces. from Categories 11. Watts for Illuminance Cate Tailored LPD Total below 1 t g ( ) 5,0761 watts: 2. Watts for Display Lighting 0 0+ 0 +0 _- .01 watts Wall Display Floor Display Ornamental/Special Very Valuable Display Effects Display 4. Total Allowed Watts (lines 1+2) �5, 761 Watts! 1 TAILORED LPD - Illuminance Categories From Table 146-D A B C D E F G 1 TASK/ACTIVITY ROOM RCR From ALLOWED ROOM or ILLUMINANCE CAVITY LTG -7 FLOOR ALLOWED WATTS NAME NON -TASK AREA CATEGORY RATIO Y N AREA LPD (E x F) Storage 123 Health Care_Utility Rm D 13.00 D9 ❑ 25 1.40 351 Storage 128 Health Care_Utility Rm D 9.75 ❑ 50 1.40 70_1 X -Ray 133 Radiatioln Therapy Isotope Kitchn - p E 4.49 M ❑ 210 1.80 378 - Dressing Dressing / Waiting Health Care VMINfM Areas - Loc Or Reading I D 5.42 0 ❑ 150 1.20 180' Dictation 129 Health Care—Med Records E 10.83 1� ❑ 36 2.50 90 Nurse Station Health Care neral ing Stns - D 5.75 2 ❑ 130 1.20 156 Restroom 111 I Health Care Toilets - C 8.71 0 ❑ 56 1.10 62 Restroom 112 Health Care Toilets C 8.71 ❑ 56, 1.101 62' Dictation 113 I Health Care—Med Records E 10.83 X 36! 2.501' 90. Storage 114 Health Care_Utility Rm D 80.09 O ❑ 70 1.40 F - -- 98;1 Nursing Station Health Care—Nursing Stns - Desk E 6.50 E ❑ 100 1.80 180 Hallways Health Care _Corridor - Nursing - C 6.64 9 ❑ 1,200 0.80 960 El El El E] ❑ ❑ El El El El El El 11 El PAGE TOTAL 2,1191 2,360 BUILDING TOTAL 4,669] _ 5,076 FTs WATTS EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page:10 of 11 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME DATE JFK Orthopedic Center I 5/7/2008 DESCRIPTION Designer Enforcement 0 §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. } ) 0 §131(d)2Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. l rr ✓ RX §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. 5111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in, the Directory. All installed fixtures shall. be certified. 0 §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. LnL /J X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to- ceiling walls. §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be �l controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. ® §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.3 by EnergySoft User Number: 5438 Job Number: Page: 11 of 11