12-0794 (RC) Title 24. BUILDING ENERGY ANALYSIS REPORT PROJECT: Cooking with Class 47-875 Caleo Bay Drive STE #107 La Quinta, CA 92253 Project Designer: Perez Collaborative Drafting Consultants 82-204 Highway 111, Suite C. Indio, Ca 92201 (760) 619-8752 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Date: 11/26/2012 DATE The EnergyPro computer program has been.used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-11-26711:44:49. 1D: I TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form MECH-MM Mechanical Mandatory Measures EnergyPro 5.1 by EnergySoR Job Number: ID: User Number: 6712 1 2 3 12 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3) PERF -1C Project Name Date Cooking with Class 11/26/2012 Project Address Climate Zone Total Cond. Floor Area Addition Floor Area 47-875 Caleo Bay Drive STE #107 La Quinta CA Climate Zone 15 2,734 I 0 GENERAL INFORMATION Building Type: ® Nonresidential ❑ High -Rise Residential. ❑ Hotel/Motel Guest Room . ❑ Relocatable - indicate ❑ specific climate zone ❑ all climates Phase of Construction: ❑ New Construction ❑ Addition ® Alteration STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6'of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Name Tim Scott [Signature , Company Scott Design and Title 24, Inc, Date 11/26%2012 Address 77-085 Michigan Drive Phone (760) 200-4780 City/State/Zip palm Desert, Ca 92211 The Principal Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the energy efficiency requirements contained in sections 110, 116 through 118, and 140 through 149 of Title 24, Part 6. Please check one: ENV. LTG. MECH. hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to ❑ ❑ ❑ sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section ❑ ❑ ❑ 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document ❑ ❑ ❑ because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. Principal Envelope Designer Name Signature Company Envelope Compliance Not /n The Scope Of This Document Date Address License # City/State/Zip Phone Principal Mechanical Designer Name Signature Company Date Address License # City/State/Zip Phone Principal Lighting Designer Name Signature Company Lighting Compliance Not In The Scope Of This Submittal Date Address License # City/State/Zip Phone INSTRUCTIONS TO APPLICANT COMPLIANCE & WORKSHEETS (check box if worksheets are included) ❑ . ENV -1C Certificate of Compliance. Required on plans. m MECH-1C Certificate of Compliance. Required on plans. ❑ LTG -1C Certificate of Compliance. Required on plans. m MECH-2C Air/Water Side/Service Hot Water & Pool Requirements. ❑ LTG -2C Lighting Controls Credit Worksheet. m MECH-3C Mechanical Ventilation and Reheat. ❑ LTG -3C Indoor Lighting Power Allowance. m MECH-5C Mechanical Equipment Details. Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2012-11-26711:44:49 /D: Page 3 of 12 PERFORMANCE CERTIFICATE OF COMPLIANCE Cooking with Class ANNUAL TDV ENERGY USE SUMMARY (kBtu/sgft-yr) Standard Proposed Complian Energy Component Design Design Margin Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process Process Lighting TOTALS 3.59 3.59 0.00 381.82 381.82 0.00 137.10 137.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 31.12 31.12 0.00 111.94 111.94 0.00 96.15 96.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 761.72 761.72 0.00 Percent better than Standard 0.0%1 ( 0.0 % excludi Part 2 of 3 Heating Cooling Fans Heat Rej Pumps DHW Lighting Receptacle Process. Process Ltg BUILDING COMPLIES PERF -1 C Date 11/26/2012 Building Orientation (S) 160 deg Conditioned Floor Area 2.734 sqft. Number of Stories 1 Unconditioned Floor Area 0 sqft. Number of Systems 2 Conditioned Footprint Area 2,734 sqft. Number of Zones 2 Natural Gas Available On Site Yes Front Elevation Left Elevation Rear Elevation Right Elevation Total Roof Orientation Gross Area (S) 714 (w) 1,272 (N) 938 (E) 600 3,524 2,734 Prescriptive Lighting Power Density Prescriptive Envelope TDV Energy Remarks: Standard 1.600 W/sgft. 254,773 sqft. sqft. sqft. sqft. sqft. sqft. Glazinn Area 444 0 480 312 1,236 0 Proposed 1.600 W/sgft. 448,716 sqft. sqft. sqft. sqft. .Sgft. sqft. Glazing Ratio 62.2% 0.0% 51.2% 52.0% 35.1% 0.0% Prescriptive Values for Comparison only. See LTG -1 C for allowed LPD. of f2 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 3 of 3) PERF -1 C Project Name Cooking with Class Date 11112612012 ZONE INFORMATION Floor Inst. Ctrl. Allowed LPD Proc. Area LPD Credits Area Tailored Loads System Name Zone Name Occupancy Type s ft. W/sf 1 W/Sf z W/sf 3 W/Sf ° W/sf Existing HVAC Existing Space Kitchen, Food Preparation 1,200 '1.600 0.274 Additional Space Kitchen, Food Preparation 1,534 "1.600 0.253 Notes: 1. See LTG -1C 2. See LTG -2C 3. See LTG -3C 4. See LTG -4C` Items above require special documentation items marked with asterisk, see LTG -11 -C by others) (by others EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified In this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justifications, and may reject a building or design that otherwise complies based on the adequacy of the special Justification and documentation submitted. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2012-11.26711:44:49 /D:. Page 5 of 12 CERTIFICATE OF COMPLIANCE and (Part 1 of 4) MECH-1C FIELD INSPECTION ENERGY CHECKLIST Project Name Cooking with Class Date 11/26/2012 Project Address 47-875 Caleo Bay Drive STE #107 La Quinta Climate Zone 15 Total Cond. Floor Area 2,734 Addition Floor Area 0 GENERAL INFORMATION Building Type: ® Nonresidential ❑ High-Rise Residential ❑ Hotel/Motel Guest Room ❑ Schools (Public School) ❑ Relocatable Public School Bldg. m Conditioned Spaces ❑ Unconditioned Spaces affidavit Phase of Construction: ❑ New Construction ❑ Addition ® Alteration Approach of Compliance: ❑ Component ❑ Overall Envelope TDV ❑ Unconditioned (file affidavit) Energy Front Orientation: N, E, S, W or in Degrees: 1180 deg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST E ui ment2 Inspection Criteria Meets Criteria or Requirements Pass Fail — Describe Reason Item or System Tags i.e. AC-1, RTU-1, HP-1 DHW Heater ❑ ❑ Equipment T e3: Electric Res DHW Boiler ❑ ❑ Number of Systems 4 ❑ ❑ Max Allowed Heating Capacity' 5,120 Btu/hr ❑ ❑ Minimum Heating Efficiency' 0.95 EF ❑ ❑ Max Allowed Cooling Capacity' n/a ❑ ❑ Cooling Efficiency' n/a ❑ ❑ Duct Location/ R-Value n/a ❑ ❑ When duct testing is required, submit MECH-4A & MECH-4-HERS n/a ❑ ❑ Economizer n/a ❑ ❑ Thermostat n/a ❑ ❑ Fan Control n/a ❑ ❑ E ui menu Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Pass Fail — Describe Reason 2_ Item or System Tags i.e. AC-1, RTU-1, HP-1 Existing HVAC ❑ ❑ Equipment T e3: Packaged DX ❑ ❑ Number of Systems 2 ❑ ❑ Max Allowed Heating Capacity' 82,500 Btu/hr ❑ ❑ Minimum Heating Efficiency' 3.30 COP ❑ ❑ Max Allowed Cooling Capacity' 82,500 Btu/hr ❑ ❑ Cooling Efficiency' 11.0 EER ❑ ❑ Duct Location/ R-Value Conditioned/4.2 ❑ ❑ When duct testing is required, submit MECH-4A & MECH-4-HERS No [3 ❑ Economizer No Economizer ❑ ❑ Thermostat Setback Required ❑ ❑ Fan Control Constant Volume ❑ ❑ 1. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes. 2. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. Compliance fails if a Fail box is checked. 3. Indicate Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other. JEnergyPro5lbyEnergySoft User Number. 6712 RunCode: 2012-11-26711:44:49 ID: Page 6 of 12 CERTIFICATE OF COMPLIANCE and (Part 2 of 4) MECH-1C FIELD INSPECTION ENERGY CHECKLIST with Class 11/26/2012 I EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201241-26711:44:49 ID: Page 7 of 12 1 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2C Project Name Date Cooking with Class 11/26/2012 Indicate Air S stems T e Central, Single Zone, Packa e, VAV, or etc... Item or System Tags i.e. AC -1, RTU -1, HP -1 Existing HVAC Number of Systems 2 Indicate Page Reference on Plans or Schedule and indicate the applicable exception(s) MANDATORY MEASURES T-24 Sections Heating Equipment Efficiency 112(a) 3.30 COP Cooling Equipment Efficiency .112(a) 11.0 EER HVAC Heat Pump Thermostat 112(b), 112(c) Yes Furnace Controls/Thermostat 112(c), 115(a) n/a Natural Ventilation i21 b Yes Mechanical Ventilation 121 b 1,243 cfm VAV Minimum Position Control 121 c No Demand Control Ventilation 121 c No Time Control 122(e) Programmable Switch Setback and Setup Control 122(e) Setback Required Outdoor Damper Control 122(f) Auto Isolation Zones 122 n/a Pipe Insulation 123 Duct Location/ R -value 124 Conditioned/4.2 PRESCRIPTIVE MEASURES Calculated Design Heating Load 144(a & b n!a Proposed Heating Capacity .144(a & b 103,055 Btu/hr Calculated Design Cooling Load 144(a & b n/a Proposed Cooling Capacity 144(a & b 122,485 Btu/hr Fan Control 144(c) Constant Volume DP Sensor Location 144(c) Supply Pressure Reset (DDC only) 144(c) Yes Simultaneous Heat/Cool 144(d) No Economizer 144 a No Economizer Heat Air Supply Reset 144(f) Constant Temp Cool Air Supply Reset 144(f) Constant Temp Electric Resistance Heating' 144 Air Cooled Chiller Limitation 144(i) Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(k) No 1. Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used explain which exception(s) to §144(8) apply. Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-11-26711:44:49 /D: Page 8 of 12 WATER SIDE SYSTEM REQUIREMENTS (Part.2 of 2 MECH-2C Project Name Date Cooking with Class 11/26/2012 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops Item System Tags (i.e. AC -C- 1, RTU -1, HP -1)' Number of Systems Indicate Page Reference on Plans or Specification 2 MANDATORY MEASURES T-24 Sections Equipment Efficiency 112 a Pipe Insulation 123 PRESCRIPTIVE MEASURES Cooling Tower Fan Controls 144(a & b Cooling Tower Flow Controls 144(h) Variable Flow System Design 144(h) Chiller and Boiler Isolation 144 CHW and HHW Reset Controls 144 WLHP Isolation Valves 144 VSD on CHW, CW & WLHP Pumps>5HP 144' DP Sensor Location 144 1. The proposed equipment need to match the building plans schedule or specifications. If a requirement is not applicable, put "WA" in the column next to applicable section. 2. For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column next to applicable section. Service Hot Water, Pool Heating Item or System Tags (i.e. WH -1, WHP, DHW, etc...)' i DHWHeater Number of Systems4 Indicate Page Reference on Plans or Schedule2 MANDATORY MEASURES I T-24 Sections SERVICE HOT WATER Certified Water Heater 111, 113(a) AO SMITH ELJF-06' Water Heater Efficiency 113(b) 0.95 EF Service Water Heating Installation 113(c) Controls Req. Pipe Insulation 123 Required POOL AND SPA Pool and Spa Efficiency and Control 114(a) n/a Pool and Spa Installation 114(b) n/a Pool Heater — No Pilot Light 115(c) n/a Spa Heater — No Pilot Light 115(d) n/a Pipe Insulation 123 n/a 1. , The Proposed equipment needs to match the building plans schedule or specifications. If a requirement is not applicable, put "N/A" in the column next to applicable section. 2. For each water heater, pool heater and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "NIX in the column. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-11-26711:44:49 /D: Page 9 of 12 MECHANICAL VENTILATION AND REHEAT MECH-3C Project Name Cooking with Class Date 11/26/2012 MECHANICAL VENTILATION §121 b 2 REHEAT LIMITATION (§144(d)) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N Condition Area Zone/System ft2 CFM per ft2 Min CFM Number By Area Of B X C People CFM per Person Min CFM REQ'D by - V.A. Occupant Max of E X F D or G Design 50% of Ventilation Design Zone Air Supply CFM CFM B X 0.4 CFM / ft2 Max. of Columns H, J, K, 300 CFM Design Minimum Air Transfer Setpoint Air Existing Space 1,200 0.15 180 21.8 25.0 545 545 545 Additional Space 1,534 0.15 230 27.9 25.0 697 697 697 Existing HVAC Total 1,243 1,243 Totals Column I Total Design Ventilation Air C Minimum ventilation rate per Section 121, Table 121-A. E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air REQ'D V.A. is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS Column D or G). I Must be greater than orequal to H, or use Transfer Air column N to make up the difference. J Desi - n fan supply CFM Fan CFM x 50%; or the design zone outdoor airflow rate per 121. K Condition area ft2 x 0.4 CFM / ft2; or L Maximum of Columns H, J, K, or 300 CFM M This must be less than orequal to Column L and greater than orequal to the sum of Columns H plus N. N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air Column H and the Design Minimum Air Column M), Column H minus M. Ene Pro 5.1 5y EnergySoft User Number: 6712 RunCode: 2012-11-26711:44:49 ID: Pae 10 of 12 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5C Project Name Cooking with Class Date 11/26/2012 CHILLER AND TOWER SUMMARY PUMPS Equipment Name Type of, Eff iciency, Tons Pump Ot . GPM BHP Control DHW / BOILER SUMMARY System Name Type Vol. Distribution aty. Rated Input (Gals). Energy Factor or RE Standby Loss Tank Ext. or Pilot R-Value Status AO SMITH ELJF-06" Small'Elec. Point of Use 4 5,120 6 0.95 n/a n/a Existing MULTI-FAMILY CENTRAL WATER HEATING DETAILS Hot Water Pump Hot Water Piping Length ft Control Ot . HP Type In Plenum Outside Buried Add Yz" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING System Name Type aty. Output Aux. kW Eff iclency Output Efficiency Status Existing HVAC Packaged DX 2 82,500 0.0 3.30 COP 82,500 11.0 EER Existing CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN System Name Fan Type Economizer Type CFM BHP CFM BHP Existing HVAC Constant Volume No Economizer 2,800 2.00 none EnergyPro 5.1 by EnemySoft User Number.' 6712 RunCode: 2012-11-26711:44:49 ID: Pae 11 of 12 MECHANICAL MANDATORY MEASURES: NONRESIDENTIAL MECH-MM . Project Name Date Cooking with Class 11/26/2012 Equipment and System Efficiencies §111: Any appliance for which there is a California standard established in'the Appliance Efficiency Regulations will comply with the applicable standard. §115(a): Fan type central furnaces shall not have a pilot light. §123: Piping, except that conveying fluids at temperatures. between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. §124: Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the CMC Standards. Controls §122(e): Each space conditioning system shall be installed with one of the following: 1A. Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or 1 B. An occupancy sensor to control the operating period of the system; or 1 C. A 4 -hour timer that can be manually operated to control the operating period of the system. 2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 §122(8)' square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. §122(c): Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. §122(b): Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone Each space conditionBng system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the §122(a&b): control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. Ventilation §121(e): Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. §122(f): All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. Ventilation System Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a §121(f): new ventilating system serving a building or space is operated for normal use, all ventilation systems serving the building ors ace shall be certified as meeting the Acceptance Requirements for Code Compliance Service Water Heating Systems §113(c) Installation 3. Temperature controls for public lavatories. The controls shall limit the outlet Temperature to 110° F. 2 Circulating service water -heating systems shall have a control capable of automatically turning off the circulating pump when hot water is not required. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-11-26711:44:49 ID: Pae 12 of 12