Loading...
07-3034 (PAT) Title 241 ' � Y �Y I - TITLE 24 REPORT Title 24 Report for: Report Prepared By: JS GLS Group 74-854 Velie Way, Suite 5 Palm Desert, CA 92260 (760) 340-3528 Job Number: LQ03 - T24-1 Date: 9/12/03 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: LQ03 - T24-1 User Number: 5553 C.CN (,5c --r BOB RUNYAN Q78-700 CABRILLO WA La-QujntaCA-922-53 Z o U o M� WE= = d Q �- m U-IL 08 o CL M Project Designer: -j 2 C0 � GLS Group o 74-854 Velie Way, Suite # 5 Palm Desert, CA 92260 760.340.3528 Report Prepared By: JS GLS Group 74-854 Velie Way, Suite 5 Palm Desert, CA 92260 (760) 340-3528 Job Number: LQ03 - T24-1 Date: 9/12/03 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: LQ03 - T24-1 User Number: 5553 C.CN (,5c --r TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 12 EnergyPro 3.1 By EnergySoft Job Number: L003 - T24-1 User Number: 5553 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R BOB RUNYAN Frame Type 9/12/03 Project Title R-38 Roof (R.38.2x4.24) Date 78-700 CABRILLO WAY La Quinta Exterior Roof Slab On Grade n/a Project Address Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade Building Permit # GLS Group (760) 340-3528 R-13 Wall w/1" EPS Wood 0.059 Plan Check / Date Documentation Author Telephone 0.387 Exterior Door Computer Performance 15 0.054 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 558 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 558 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-13 Wall w/1" EPS Wood 0.059 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-15 Wall w/1" EPS Wood 0.054 Exterior Wall FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front 8.0 0.43 0.41 Bug Screen ❑ X❑ ❑ x❑ Left 44.0 0.59 0.66 Bug Screen ❑ x❑ ❑X❑ Rear 25.0 0.43 0.41 Bug Screen ❑ x❑ ❑ x❑ Rear 4.0 0.59 0.66 Bug Screen ❑ X❑ ❑ 0 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑❑ Run Initiation Time: 09110/03 21:14:59 Run Code: 1063253699 Ener Pro 3.1 By Ener Soft User Number: 5553 Job Number: LQ03 - T24-1 Pa e:3 of 12 Certificate of Compliance: Residential (Part2 of 2) CF -1 R BOB RUNYAN 9/12/03 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFU E/HSPF) (ducts, attic, etc.) R -Value Type Comments (`Pntral Furnaces 80% AFUE Ducts in Attic 42 Setback HVAC lit System Gas Elec Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.1 SEER Ducts in Attic 42 Setback HVAC S Ip it Systesm rac/FIPr. WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with over responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification a ield veri tion by an approved HERS rater. esigner r wrier (per Bus'ness & Professio s Code) Documentation Author Name: is Title/Firm: GLS Group Title/Firm: GLS Group Address: 74-854 Velie Way, Suite # 5 Address: 74-854 Velie Way, Suite 5 Palm Desert, CA 92260 Palm Desert, CA 92260 Te I e p h o n e: 760.340.3528 Lic. kz—. 9 - v -2 V— :> (S! u ) (date) Enforce nt Agency Name: Title/Firm: _ Address: Telephone: Telep ne: (760) 340-3528 6T•l2.2 (sign (date) (signature/stamp) (date) Run Initiation Ti I n Code: EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: LQ03 - T24-1 PageA of 12 Certificate of Compliance: Residential (Addendum) CF -1 R BOB RUNYAN 9/12/03 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3ased on the adequacy of the special Justification ano aocumentation suomiaea. Plan Field TheHVAC System "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C -2R) - Verify Thermal Mass: 338 sgft Covered Slab Floor, 3.50" thick at WHOLE HOUSE HIGH MASS Design(see C -2R) - Verify Thermal Mass: 220 sqft Exposed Slab Floor, 3.50" thick at WHOLE HOUSE HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form cF-61R. Plan Field The HVAC System "HVAC Split System Gas/Elec" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC Split System Gas/Elec" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 09/10/03 21:14:59 Run Code: 1063253699 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: LQ03 - T24-1 Page:5 of 12 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. *§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). *§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. []*§150(d): §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ Gas Appliances Gas Logs. §150(e): Installation of Fireplaces, Decorative and 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment; water heaters, showerheads and faucets certified by the Commission. ❑ §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: LQ03 - T24-1 Page:6 of 12 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X❑ '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5553 Job Number: LQ03 - T24-1 Page:? of 12 Comouter Method Summary (Part 1 of 3) C -2R BOB RUNYAN 9/12/03 Project Title Date 78-700 CABRILLO WAY La Quinta Project Address Building Permit # GLS Group (760) 340-3528 Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 4.01 Facing North Margin 45 Facing East Margin Facing South Margin R=38RooQR-38.2x4-24.) Facing West Margin 1.80 2.21 3.05 0.96 3.94 0.07 3.14 0.87 Space Cooling 55.75 56.76 -1.00 .R--13_WalLw/J.LE2S 53.41 2.34 Wall- x.6.3 45.26 10.49 1.35- 51.60 4.15 Domestic Hot Water 0.00 0.00 0.00 .RR13_Wall_w/a-EeS 0.00 0.00 W l� M 0.00 0.00 t80 0.00 0.00 58.56 1.20 56.46 3.30 49.20 10.56 54.74 5.02 Totals 59.76 -0-05-9- _2.7_0. 90 This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 558 ft Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 14.5% Number of Dwelling Units: 1.00 Total Conditioned Volume: 5,580 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 558 ft2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area ±wAC-Split-System_Gas/Eler 558 -5,580 -1_0.0_ Conditioned- -Setback- -2 -nla OPAQUE SURFACES Solar Act. Gains Tvoe Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Raof 52]. 0-024- 45 18- R=38RooQR-38.2x4-24.) WHOLF HO.U.SF Wall -22.0 0 059 -0--9-0- ❑ .R--13_WalLw/J.LE2S WHOLE_H.O' ISE Wall- x.6.3 0_059 1.35- 9.0- ❑ .RR13_Wall_w/a-EeS WHOLEt10.U.SF W l� M 0..059 t80 90 ❑ R13_WalLw/1LEeS WHOLE_t1QUSE Wall- 2t9 -0-05-9- _2.7_0. 90 ❑ 1-1.3 Wall _wL1_EES WHOLE_HQU.SE 21 0._3.87_ -2.7.0_ 90_ � ❑ _Solid_Wood-D.00r WH..01 F: Hn.USF -Doo-L-- Wall 21 -0,05A- t35 90 ❑ R=15_Wallyv/-ILEP_S WHOLE -H SE IlooL-- 24- 0 387_ -D5 90 -Solid -Wood -Doo, WHO.LE_IiQU.SE ❑ ❑ ❑ ❑ ❑ ❑ - ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑❑ ❑❑ F-1 F-1 Run Initiation Time: 0913 21:14:$9 Run Code: 10632 369 3.1 By EnergySoft User Number: 5553 . LQ03 - T24-1 Page:8 of 12 Computer Method Summary (Part 2 of 3) C -2R BOB RUNYAN 9/12/03 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 4 Window Front (North) —4.-0_ —0._4.3.0_ 0._41. 0_ —90. Milgard_W_—AL.U.MIN.UM_Low E_ WHOLE HOUSE 2 Window Front North. 4.0 0.430 0.41 0 90 Milgard W. ALUMINUM Low E WHOLE HOUSE 3 Window Left Southeast) 24.0 0.590 0.66 135 90 Milgard W. ALUMINUM Low E WHOLE HOUSE 4 Window Left Southeast) 20.0 0.590 0.66 135 90 Milgard W. ALUMINUM Low E WHOLE HOUSE 5 Window Rear (South) 25.0 0.430 0.41 180 90 Milgard W. ALUMINUM Low E WHOLE HOUSE 6 Window Rear (South) 4.0 0.590 0.66 180 90 Milgard W. ALUMINUM Low E WHOLE HOUSE INTERIOR AND EXTERIOR SHADING Right Fin Window Overhang Left Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hg_t. LExt. RExt. Dist Len Hgt Dist Len Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 Run Initiation Time_09I141Q3 21:14:59 Run Code: 1063253699 EnergyPro 3.1 -y�neMySoft User Number: 5553 Job Number: LQ03 - T24-1 Page:9 of 12 Computer Method Summary (Part 3 of 3)' C -2R BOB RUNYAN 9/12/03 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Corn er to eavyweight— —3.38. _3..5.0 _28. 0-98. n1a _2. y1fLiQLE_Ii01lSE_/_Slab_o�Grade Concrete. Heavyweight 220 3.50 28 0.98 n/a 0 WHOLE HOUSE /Slab on Grade PERIMETER LOSSES Type F2 Length Factor Insulation R -Val. Depth Location / Comments 5i a Perimeter 510 7f _00 0 WHOLE HOUSE Slab— edmeter 48 016. —0-0 0 W_--110lEdQlZSE HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Antral Furnace 80° AF1�E Dols in Attic 4.2 Setback HVAC S Iit�System Ga�/EJec Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments SplitAir ConditiQner 12.1 $EER Ducts in Attic 4.2 Setback HVAC Split System—G-as/Elec WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type S sy t. Btu/hr (gam Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 09/10/03 21:14:59 Run Code: 1063253699 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: LQ03 - T24-1 Page: 10 of 12 Computer Method Summary (Addendum) C -2R BOB RUNYAN 9/12/03 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special lustmcation ana aocumentation suamittea. Plan Field The HVAC System "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C -2R) - Verify Thermal Mass: 338 sgft Covered Slab Floor, 3.50" thick at WHOLE HOUSE HIGH MASS Design(see C -2R) - Verify Thermal Mass: 220 sgft Exposed Slab Floor, 3.50" thick at WHOLE HOUSE HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the tiew vermcation ana aiagnostic testing of these measures on a torm (A --15K. Plan Field The HVAC System "HVAC Split System Gas/Elec" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC Split System Gas/Elec" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 09/10/03 21:14:59 Run Code: 1063253699 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: LQ03 - T24-1 Page: 11 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE BOB RUNYAN 9/12/03 SYSTEM NAME FLOOR AREA HVAC Split System Gas/Elec 558 26.0 of 69.5 of Outside Air 0 cfm Supply Fan 1000 cfm 69.5 of TEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensible Latent I CFM Sensible 307 6,555 0 311 9,646 0 328 482 0 0 0 0 011 0 0 0 0 328 482 7,210 0 10 610 HVAC EQUIPMENT SELECTION York H4DH030/P4HUB12LO32 U8H 21,994 4,624 32,000 Total Adjusted System Output 21,994 4,624 32,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12am 69.5 of ® 99.6 of Heating Coil �% Return Air Ducts 4 11.0 177.6 of 78.3 / 63.8 of 78.3 / 63.8 of 57.6 / 56.4 of Outside Air O 0 cfm Supply Fan 1000 cfm 78.3/63.8 of Cooling Coil �% Return Air Ducts `i n Supply Air Ducts 99.2 of ROOMS 70.0 of Supply Air Ducts 57.9 / 56.6 of 45.8% R.H. ROOMS 78.0 / 63.7 of EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: LQ03 - T24-1 Page: 12 of 12