Loading...
BRES2018-0341 Title 24 AdditionalBUILDING ENERGY ANALYSIS REPORT 1*65 mil$ a 3slI PROJECT: MURRAY RESIDENCE's addition 78190 CALLE CADT LA QUINTA, CA 92253 Project Designer: GLS ARCHITECTURE GROUP INC. 74991 JONI DR #9 PALM DESERT, CA 92260 60 340.3528 Report Prepared by: Armando Chavez 44890 SEELEY LA QUINTA, CA 92253 760 278.1840 Job Number: TY OF LA QUINT A BUILDING REVIEWED FOR R CODE COMPLIANCE L RECE'VED 18 - GLS / 109 - 083 �C i 6ui Date: O1TY or LA QUINTA 10/10/2018 OOMMUNI"iY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 ' Table of Contents 2 ` Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 12 Form MF-1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MURRAY RESIDENCE's addition Calculation Description: Title 24 Analysis Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Input File Name: 083 - 78190 CALLE CADIZ.ribd16x CF1 R-PRF-01 Page 1 of 9 GENERAL INFORMATION 01 Project Name MURRAY RESIDENCE's addition 02 Calculation Description Title 24 Analysis 03 Project Location 78190 CALLE CADIZ 04 City LA QUINTA 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2016 3.1 (1019) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 4605 15 Number of Zones 2 16 Slab Area (ft2) 4605 17 Number of Stories 1 18 Addition Cond. Floor Area (ft2) 1192 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 1192 21 Glazing Percentage (%) 11.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.79 3.95 -2.16 -120.7% Space Cooling 92.33 89.73 2.60 2.8% IAQ Ventilation 0.76 0.76 0.00 0.0% Water Heating 5.85 5.85 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ----- Compliance Energy Total 100.73 100.29 0.44 0.4% Registration Number: 218-Po10276852A-000-000-0000000-0000 Registration Date/Time: 2018-10-10 12:41:11 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: MURRAY RESIDENCE's addition Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: 083 - 78190 CALLE CADIZ.ribd16x REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Raised heel truss • Cool roof • Window overhangs and/or fins • Exposed slab floor in conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Fan Efficacy WattsICFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: - None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ftz) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems MURRAY RESIDENCE's addition 4605 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 (E) 3413 Conditioned AC-1 3413 9 DHW Sys 1 n/a (N) - 1192 Conditioned AC-1 1192 9 DHW Sys 1 n/a Registration Number: 218-P010276852A-000-000-0000000-0000 Registration Date/Time: 2018-10-10 12:41:11 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MURRAY RESIDENCE's addition Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Calculation Description: Title 24 Analysis Input File Name: 083 - 78190 CALLE CADIZ.ribdl6x CF1 R-PRF-01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Wall Exception Status Verified Existing Condition E - 645 (E) 3413 Def Wall '92 to Presentl 90 Right 645 58.32 90 n/a Existing No S - 762 (E) 3413 Def Wall '92 to Presentl 180 Front 762 285.435 90 n/a Existing No W - 270 (E) 3413 Def Wall '92 to Presentl 270 Left 325 12 90 n/a Existing No TO GARAGE (E) 3413» (N) - 1192 Def Wall '92 to Present 180 0 n/a Existing No 3413 (E) 3413 Def Roof'78 to Present 3413 n/a Existing No N - 479 (N)-1192 R-21 Wall 0 Back 479 153 90 none New n/a E - 248 (N)-1192 R-21 Wall 90 Right 248 0 90 none New n/a W- 306 (N)-1192 R-21 Wall 270 Left 306 50 90 none New n/a N TO GARAGE (N)-1192 R-15 Wall -- 427 16.66 n/a New n/a 1192 (N)-1192 R-38 + CRRC 0.86-0.88 1192 n/a New n/a ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic (E) 3413 Attic Roof(E) 3413 Ventilated 1 0.1 0.85 No No Existing No Attic (N) - 1192 Attic Roof(N) - 1192 Ventilated 0.2 0.86 0.88 Yes Yes New No Registration Number: 218-P010276852A-000-000-0000000-0000 Registration Date/Time: 2018-10-10 12:41:11 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MURRAY RESIDENCE's addition Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Calculation Description: Title 24 Analysis Input File Name: 083 - 78190 CALLE CADIZ.ribd16x CF1 R-PRF-01 Page 4 of 9 FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Status Verified Existing Condition 2450 E - 645 (Right-90) ---- --- 1 11.7 0.51 0.24 Insect Screen (default) Altered n/a 24502 E - 645 (Right-90) - - 1 11.7 0.51 0.24 Insect Screen (default) Altered n/a 5050 E - 645 (Right-90) -- 1 25.0 0.51 0.24 Insect Screen (default) Altered n/a 2050 E - 645 (Right-90) - 1 10.0 059 0.40 Insect Screen (default) Existing No 5080 S - 762 (Front-180) - - 1 40.0 0.51 0.24 Insect Screen (default) Altered n/a 8080 S - 762 (Front-180) 8.0 8.0 1 64.0 0.59 0.40 Insect Screen (default) Existing No 5480 S - 762 (Front-180) 5.3 8.0 1.014 43.0 0.59 0.40 Insect Screen (default) Existing No 5414 S - 762 (Front-180) 5.0 1.3 1.094 7.1 0.59 0.40 Insect Screen (default) Existing No 6050 S - 762 (Front-180) 6.0 5.0 1 30.0 0.59 0.40 Insect Screen (default) Existing No 10080 S - 762 (Front-180) 10.0 8.0 1 80.0 0.59 0.40 Insect Screen (default) Existing No 2020 W - 270 (Left-270) ---- ---- 1 4.0 0.59 0.40 Insect Screen (default) Existing No 20202 W - 270 (Left-270) - - 1 4.0 0.59 0.40 Insect Screen (default) Existing No 20203 W - 270 (Left-270) 1 4.0 0.59 0.40 Insect Screen (default) Existing No 80802 N - 479 (Back-0) -- 1 64.0 0.51 0.24 Insect Screen (default) New n/a 80803 N - 479 (Back-0) - 1 64.0 0.51 0.24 Insect Screen (default) New n/a 50502 N - 479 (Back-0) ---- 1 25.0 0.51 0.24 Insect Screen (default) New n/a 2680 W- 306 (Left-270) - 1 20.0 0.51 0.24 Insect Screen (default) New n/a 60502 W- 306 (Left-270) - 1 30.0 0.51 1 0.24 Insect Screen (default) New n/a OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U-factor Status Verified Existing Condition 2880 S - 762 21.3 0.50 Existing No Registration Number: 218-P010276852A-000-000-0000000-0000 Registration Date/Time: 2018-10-10 12:41:11 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MURRAY RESIDENCE's addition Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Calculation Description: Title 24 Analysis Input File Name: 083 - 78190 CALLE CADIZ.ribd16x CFI R-PRF-01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 8080 6 0.1 6 6 0 0 0 0 0 0 0 0 0 5480 6 0.1 6 6 0 0 0 0 0 0 0 0 0 5414 6 0.1 6 6 0 0 0 1 0 0 0 0 0 0 6050 2 1.33 2 2 0 0 0 0 0 0 0 0 0 10080 8 0.1 8 8 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers - Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Roof(E) 3413 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) - Inside Finish: Gypsum Board Ceilings (below - Cavity/Frame: R-9.1 /2x4 Def Roof '78 to Present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 - Over Ceiling Joists: R-9.9 insul. - Inside Finish: Gypsum Board Cavity / Frame: R-13 / 2x4 Def Wall '92 to Present Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 - Other Side Finish: Gypsum Board • Inside Finish: Gypsum Board • Cavity/ Frame: R- 13 / 2x4 Def Wall '92 to Presentl Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.101 • Exterior Finish: 3 Coat Stucco - Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Roof(N) - 1192 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 - Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below 2x4 @ 24 in. O.C. with Raised Heel - Cavity/Frame: R-9.1 /2x4 R-38 + CRRC 0.86-0.88 attic) Wood Framed Ceiling Truss Height 20 in R 38 0.025 - Over Ceiling Joists: R-28.9 insul. - Inside Finish: Gypsum Board - Cavity / Frame: R-15 / 2x4 R-15 Wall -- Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.086 • Other Side Finish: Gypsum Board - Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco Registration Number: 218-P010276852A-000-000-0000000-0000 Registration Date/Time: 2018-10-10 12:41:11 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MURRAY RESIDENCE's addition Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Calculation Description: Title 24 Analysis Input File Name: 083 - 78190 CALLE CADIZ.ribd16x CF1 R-PRF-01 Page 6 of 9 SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ftz) Perimeter (ft) Edge Insul. R-value Carpeted Fraction Heated Status Verified Existing Condition 34132 (E) 3413 3413 0.1 None 0.8 No Existing No 11922 (N)-1192 1192 0.1 None 0 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) I Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / NEEA Heat Pump or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Brand / Model Condition DHW Heater 1 Gas Small Storage 1 50 0.525 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 Distribution Verified Existing SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Name Status Condition AC-1 Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution Altered No System System 1 Registration Number: 218-P010276852A-000-000-0000000-0000 Registration Date/Time: 2018-10-10 12:41:11 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MURRAY RESIDENCE's addition Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Calculation Description: Title 24 Analysis Input File Name: 083 - 78190 CALLE CADIZ.ribd16x CF1 R-PRF-01 Page 7 of 9 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 2 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 PkgAirCond 2 11 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Not Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 I 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification Ducts located in attic Air Distribution Air Distribution (Ventilated and Sealed and tested 8.0 Attic Attic None Altered No System System 1 Unventilated) 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a HVAC - FAN SYSTEMS 8: HERS VERIFICATION 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required Registration Number: 218-P010276852A-000-000-0000000-0000 Registration Date/Time: 2018-10-10 12.41:11 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MURRAY RESIDENCE's addition Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Calculation Description: Title 24 Analysis Input File Name: 083 - 78190 CALLE CADIZ.ribd16x CF1 R-PRF-01 Page 8 of 9 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 76 0.25 Default 0 Required PROJECT NOTES -- ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. -- LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. -- AC EQUIPMENT'S EFFICENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. -- ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY. Registration Number: 218-P010276852A-000-000-0000000-0000 Registration Date(Time: 2018-10-10 12:41:11 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MURRAY RESIDENCE's addition Calculation Date/Time: 12:24, Wed, Oct 10, 2018 Calculation Description: Title 24 Analysis Input File Name: 083 - 78190 CALLE CADIZ.ribd16x CFI R-PRF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signaturr- l-� ARMANDO CHAVEZ —� Company: Signature Date: TITLE 24 OF THE DESERT 2018-10-10 12:40:55 Address: CEA/HERS Certification Identification (If applicable): 74800 Shirley #62 N.A. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature - Ruben Romero`"s` Company: Date Signed: GLS ARCHITECTURE GROUP INC 2018-10-10 12:41:11 Address: License: 74491 JONI DR SUITE #9 N.A. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. �T M [o- Easy to Verify at CaICERTS.com Registration Number: 218-P010276852A-000-000-0000000-0000 Registration Date/Time: 2018-10-10 12:41:11 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-10-10 12:24:59 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name MURRAY RESIDENCE'S addition Project Address 78190 CALLE CADIZ LA QUINTA Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family [21 Existing+ Addition/Alteration California Energy Climate Zone ' Total Cond. Floor Area Addition CA Climate Zone 15 4,605 1,192 Date 1011012018 # of Units 1 INSULATION Construction TyRe Cavity Area ftz Special Features Status Roof Wood Framed Attic R 19 3,413 Existing Slab Unheated Slab -on -Grade - no insulation Demising Wood Framed R 13 3,413 Perim = 0' 1,556 Existing Existing Door Opaque Door - no insulation 21 Existing Roof Wood Framed Attic R 38 1,192 Cool Roof New Slab Unheated Slab -on -Grade - no insulation 1,192 Perim = 0' New Demising Wood Framed R 15 410 New Wall Wood Framed R 21 830 New FENESTRATION I Total Area: 537 Glazing Percentage: 11.7% Now/Altered Average U-Factor; Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades 0.51 Status Right (E) 48.3 0.510 0.24 none none Bug Screen Altered Right (E) 10.0 0.590 0.40 none none Bug Screen Existing Front (S) 40.0 0.510 0.24 none none Bug Screen Altered Front (S) 114.1 0.590 0.40 6.0 none Bug Screen Existing Front (S) 30.0 0.590 0.40 2.0 none Bug Screen Existing Front (S) 80.0 0.590 0.40 8.0 none Bug Screen Existing Left (lM 12.0 0.590 0.40 none none Bug Screen Existing Rear (N) 153.0 0.510 0.24 none none Bug Screen New Left (M 50.0 0.510 0.24 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Packaged Air Condition 14.0 SEER Setback Altered HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R-Value Status AC- Ducted Ducted Attic 8.0 Altered WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnenqyPro 7.1 by Ener-qySoft User Number: 20648 ID: 18 - GLS / 109 - 083 Paae 12 of 17 2016 Low -Rise Residential Mandatory Measures Summary NOTE.' Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. `Exceptions may apply. Uf+ +nal Ut 2o1Yi Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMAICSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing § 110.8(i): material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CF1 R. § I10.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)l: requirement also applies to controlled ventilation crawls ace for buildings complying with the exce tion to § 1 50.0d . Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are lomolhibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the EneTy Commission.' § 110.2(a): _ HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.` Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heatin .' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 11 0.3c 5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank Pushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions s ecified in 150.0�. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.` § 150.00)26: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casin2 or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class 11 vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC) or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)12. Z2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air systems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providinq whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testin , in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate piping, filters and valves.` Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9: § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JAB.` § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G; functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in 5 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)38: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150,0 k 3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must com I with the applicable requirements in 5§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(G). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9 130.0, 130.1, 130.4,140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. Ina low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: I. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all desi ned paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10(b) throw h § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane' Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof § 110.10(b)4: dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for roWng of plumbing from the solar zone to the water-heati swam. Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.1 Old): 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name MURRAY RESIDENCE'S addition System Name AC- Date 10/10/2018 Floor Area 4,605 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 LCFM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL 5,388 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 100,000 49,239 1,621 1,292 37,303 Total Output Btuh 200,000 0 Output Btuh/s ft 43.4 2,842 1,833 Cooling System 0 0 Output perSystem 58,000 0 0 0 0 Total Output Btuh 116,000 0 1,621 0 Total Output(Tons) 9•7 2,842 1,833 Total Output Btuhls ft 25.2 Total Output s ftrron 476.4 54,924 40,969 Air System CFM perSystem 3,400 HVAC EQUIPMENT SELECTION Airflow cfm 6,800 RTU 5-TON 14/11/0.80 SEER/EER/AFUE 67,831 29,841 200,000 Airflow cfm/s ft 1.48 Airflow cfmrron 703.4 Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 200,000 Jan 1 AM Outside Air % 0•0% 67,831 29,841 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Heating Peak 26 OF 68 OF 68 OF 95 OF • Outside Air - 0 cfm Supply Fan Heating Coil 6,800 cfm 68 IF f I! ROOM An 68 IF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112 l73 OF 75 / 62 OF 75 / 62 OF 66 / 58 °F Outside A-' ❑ _ 0 cfm Supply Fan Cooling Coil 6,800 cfm 75 / 62 IF T�-� ' 46.4% 1 66 ! 58 OF ROOM 75161 OF EnergyPro 7.1 by EnergySoit User Number: 20648 ID: 18 - GLS / 109 - 083 Page 17 of 17