04-8046 (SFD) Title 24V TITLE 24- REPORT Title 24 Report for: CASA ESTELLA 78225 Calle Cadiz La Quinta, Ca 92253 Project Designer: LENCH DESIGN STUDIO, INC. P.O. BOX 450 LA QUINTA, CA 92247-0450 760/564-1866 Report Prepared By: VERNA LENCH Lench Design Studio, Inc. P.O. Box 450 La Quinta, CA 92247-0450 (760) 564-1866 Job Number: 3.1-1316 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED. FOR CONSTRUCTION DATE -d ---Z 7O-5�r5,7 iOrrlcC Date: 12/17/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 3.1-1316 User Number: 5454 I i TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 7 8 15 18 21 24 EnergyPro 3.1 By EnergySoft Job Number: 3.1-1316 User Number: 5454 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R CASA ESTELLA 12/17/2004 Project Title Date 78225 Calle Cadiz La Quinta Project Address Building Permit # Lench Design Studio, Inc. (760) 564-1866 Plan Check /Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,075 f? Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 4,075 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Location/Comments attic, garage, typical, etc. Exterior Roof Exposed Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Door Exterior Wall Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Const. Component Frame Assembly Type Type U -Value R-38 Roof (R.38.2x14.16) Wood 0.028 Slab On Grade n/a 0.756 R-19 Wall (W.19.2x6.16) Wood 0.065 Solid Wood Door None 0.387 R-19 Wall w/1" EPS Wood 0.045 Slab On Grade n/a 0.756 Location/Comments attic, garage, typical, etc. Exterior Roof Exposed Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Door Exterior Wall Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins • SF U -Factor SHGC Shading Yes / No Yes / No Skylight 4.8 0.71 0.50 None ❑ X❑ ❑ X❑ Left (East) 22.5 0.60 0.37 Bug Screen ❑ Q ❑ 0 Left (East) 96.0 0.74 0.37 Bug Screen ❑ Q ❑ Q Rear (South) 18.0 0.60 0.37 Bug Screen ❑ 0 ❑ X❑ Rear (South) 101.3 0.46 0.37 Bug Screen ❑ 0 ❑ 0 Right (Wgst) 40.0 0.74 0.37 Bug Screen ❑X ❑ ❑x❑ Front (North) 45.0 0.60 0.37 Bug Screen ❑ X❑ ❑ x❑ Front (North) 68.4 0.46 0.37 Bug Screen ❑ x❑ ❑ ❑x Front (Northeast) 23.6 0.46 0.37 Bug Screen ❑ X❑ ❑ X❑ Right (Northwest) 5.6 0.46 0.37 Bug Screen ❑ X❑ ❑ X❑ Front (North) 18.0 0.61 0.39 Bug Screen ❑ X❑ ❑ x❑ Rear (Souter . 192.0 0.74 0.37 Bug Screen x❑ ❑ ❑ X❑ Run Initiation Time: 12/17/04 09:12:27 Run Code: 1103303547 EnergyPro 3.1 By Ener oft User Number: 5454 Job Number: 3.1-1316 Pa e:3 of 29 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R CASA ESTELLA 12/17/2004 Project Title Date 78225 Calle Cadiz La Quinta Project Address Building Permit # Lench Design Studio, Inc. (760) 564-1866 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,075 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 4,075 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shadinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (South) 85.5 0.46 0.37 Bug ScreenX❑ ❑ ❑ x❑ Rear (South) 6.0 1.28 0.80 Bug Screen ❑ ❑ o Left (East) 9.6 0.46 0.37 Bug Screen❑ X❑ ❑ ❑x Right (West) 12.0 0.46 0.37 Bug Screen( y] ❑ ❑x Right (West) 42.0 0.61 0.39 Bug Screen❑ X❑ ❑ X❑ Front (North) 9.0 0.62 0.38 Bug Screen❑ X❑ ❑ x❑ Right (West) 9.0 0.62 0.38 Bug Screen ❑ o ❑ o Rear (South) 36.0 0.61 0.39 Bug Screen ❑X❑ ❑ ❑x ❑ ❑ ❑ ❑ El 1:1 El F-1 ❑ ❑ ❑ ❑ EJ EJ El El Run Initiation Time: 12/17/04 09:12:27 Run Code: 1103303547 EnergyPro 3.1 By Energ ySoft User Number: 5454 Job Number: 3.1-1316 Pa e:4 of 29 ' Certificate of Compliance: Residential (Part 2 of 2) CF -1 R CASA ESTELLA 12/17/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Fumare 80% AFUE Ducts in Attic 42 Setback HVAC System - Zone 1 Central gurnace 80% AFUE Ducts in Attir. 42 Sethark HVAC S..ystPm - Zone 2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner Split Air Conditioner Split Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -75-230 Small Gas Recirc/Demand 1_ 75,000 75 0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS AUTHORIZATION FOR USE OF THIS TITLE 24 REPORT ONLY WITH ORIGINAL SIGNATURES. NO DUPLICATION PERMITTED! COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: LENCH DESIGN STUDIO, INC. Address: P.Q BOX 450 Telephon9 60/564-1866 Lic. #: A Age Name: _ Title/Firm: _ Address: Telephone_ /Z . /7.v Name: VERNA LENCH Title/Firm: Lench Design Studio, Inc. Address: P.O. Box 450 La Quinta, CA 92247-0450 Telephone: (760) 564-1866 a signature) (d e) (signature/stamp) (date) Run Initiation Time: 12/17/04 09:12:27 Run Code: 1103303547 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page:5 of 29 Certificate of Compliance: Residential (Addendum) CF -1 R CASA ESTELLA 12/17/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 0 sqft Covered Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 789 sqft Exposed Slab Floor, 3.50" thick at Zone 1 The HVAC System "HVAC System - Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 216 sqft Covered Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1055 sqft Exposed Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1543 sqft Covered Slab Floor, 3.50" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 472 sqft Exposed Slab Floor, 3.50" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC System - Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System - Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System - Zone 3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. I EneravPro 3.1 By EnemySoft User Number: 5454 Job Number: 3.1-1316 Paae:6 of 29 I Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER JENFORCEMEN1 Building Envelope Measures F'§150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. .§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑ '§ 150(d): Minimum R-13 raised floor insulation in framed floors. ❑ § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ❑X §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous buming gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X] §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. X❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. X❑ '§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. X1 §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. FX§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. RI150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and . recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page:7 of 29 Computer Method Summary (Part 1 of 3) C -2R CARR FSTFI I A Project Title 12/17/2004 Date 78225 C,',qtl*7 I a nl tints .aIle Project Address Building Permit # I Design Studio, Inr._ (760) 564-1866 .nch Documentation Author Telephone Plan Check/Date Comp tt _r Performance Compliance Method Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.49 3.78 -0.29 Space Cooling 35.49 33.74 1.75 Domestic Hot Water 6.99 6.96 0.03 Totals 45.98 44.48 1.50 GENERAL INFORMATION Conditioned Floor Area: 4,075 Floor Construction Type: X� Slab Floor Building Type: Single Fam Detached Raised Floor Building Front Orientation: (North) 0 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 40,750 Number of Stories: 1 Slab Floor Area: 4,075 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC Systpm - Zone 1 789 7 890 019 ConrlitinnPri SPthark _2 n/a HVAC . �stpm - Zone 2 1 271 12 710 031 Conditinned S . hank n/a HVAC Syctpm - Zone 3 2,(L 20,150 0-49 Cnnrlifinned S _tthark n/ OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Rnnf 7.88 0.028 0 0 Wall X45 n.o65 n An nnnr 20 0.387 f) An Wall 230 0.045 go 90 Wall 105 0.045 180 90 Wall J31 n.045 180 AD Wall X31 0.045 270 90 Rnnf 1 271 0.028 0 ! 0 Wall 103 0.045 -0 `go Wall 84 0.045 45 An Wall 12 0.045 315 go Wall 20 0.045 0_90 poor 28_ 0.387 0 _9Q Wall 12 0.045 45 An Wall 84 n.045 315 An Wall 58 0.045 0 _90 Wall 166 0.045 1R0 90 Wall 29 0.045 270 go Wall 28 0.045 180 90 Roof 9 011 0.028 0 a Wall �60 0.045 90 go Wall 41 0045 45 An Wall 128 0 045 _go _9d Wall X51 0.045 0 _91i Wall 239 0-045 270 -9,Q Wall �20 0.045 0 _1Q Wall 93 0.045 270 _9Q Wall 0.045 0 _ 90 Wall_ 260 0.045 270 gQ Form 3 Reference Location / Comments I EnerovPro 3.1 By EnergvSoft User Number. 5454 Job Number: 3.1-1316 Page:8 of 29 1 Computer Method Summary (Part 1 of 3) C -2R CASA FSTE1 I A Project Title 12/17/2004 Date 78225 Calle Cadiz La Quinta Project Address Building Permit # Lenc:h nesian Studio, Inc. (760) 564-1866 Documentation Author Telephone Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check!Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.49 3.78 -0.29 Space Cooling 35.49 33.74 1.75 Domestic Hot Water 6.99 6.96 0.03 Totals 45.98 44.48 1.50 GENERAL INFORMATION Conditioned Floor Area: 4,075 Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Act. Type Area U -Val. Azm. Tilt Wall 46 0.065 180 90 Wall 105 0.065 270 X30_ Wall 23 0.045 180 gd Wall 143 0.045 180 90 Wall 89 0.045 180 CiQ Wall 225 0 Q4 gn W0_ Solar Gains Floor Construction Type: XX Slab Floor ❑ Raised Floor Total Conditioned Volume: 40,750 Slab Floor Area: 4,075 # of Thermostat Vent Units Zone Type Type Hgt. Area Y / N Form 3 Reference Location / Comments Zone 3 Run Initiation Time: 12/17/04 09:12:27 Run Code: 1103303547 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page:9 of 29 Computer Method Summary (Part 2 of 3) C -2R CASA ESTELLA 12/17/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1 Skylight_Front ( nrth) 0.6 0.710 0.50 f_ 0 Snlatuhe Znne 1 2 Window Left (East) 9.0 0.600 0.37 90 90 Summit 5500 Al DP Low E Zone 1 3 Window Left (East) 24.0 0.740 0.37 90 90 Summit 5500 Al DP Low E Zone 1 4 Window Rear (South) 9.0 0.600 0.37 180 90 Summit 5500 Al DP Low E Zone 1 5 Window Rear (South) 29.3 0.460 0.37 180 90 Summit 5500 Al DP Low E Zone 1 6 Window Rear (South) 9.0 0.600 0.37 180 90 Summit 5500 Al DP Low E Zone 1 L Window Rear (South) 42.0 0.460 0.37 180 90 Summit 5500 Al DP Low E Zone 1 8 Window Right (West) 40.0 0.740 0.37 270 90 Summit 5500 Al DP Low E Zone 1 6 Window Front (North) 18.0 0.600 0.37 0 90 Summit 5500 Al DP Low E Zone 2 1Q Window Front (North) _ 36.0 0.460 0.37 0 _ 90 Summit 5500 Al DP Low E Zone 2 1 Window Front (North) 18.0 0.460 0.37 0 90 Summit 5500 Al DP Low E Zone 2 12 Window Front (Northeast) 5.6 0.460 0.37 45 90 Summit 5500 Al DP Low E Zone 2 13. Window Front (North) 4"8 0.460 0.37 0_ 90 Summit 5500 Al DP Low E Zone 2 14 Window Right (Northwest) 5.6 0.460 0.37 315 90 Summit 5500 Al DP Low E Zone 2 15 Window Front (North) 18.0 0.610 0.39 0 90 Summit 5500 Al DP Low E Zone 2 16 Window Front (North) 6.0 0.460 0.37 0 90 Summit 5500 Al DP Low E Zone 2 17 Window Rear (South) 48.0 0.740 0.37 180 90 Summit 5500 Al DP Low E Zone 2 18 Window Rear (South) 48.0 0.740 0.37 180 90 Summit 5500 Al DP Low E Zone 2 1.Q Window Rear (South) 18.0 0.460 0.37 180 90 Summit 5500 At DP Low E Zone 2 20 Window Rear (South) 18.0 0.460 0.37 180 90 Summit 5500 Al DP Low E Zone 2 21 Window Rear (South) 48.0 0.740 0.37 180 90 Summit 5500 Al DP Low E Zone 2 2-2 Window Rear (South) 48.0 0.740 0.37 180 90 Summit 5500 Al DP Low E Zone 2 23 Window Rear (South) 18.0 0.460 0.37 180 90 Summit 5500 Al DP Low E Zone 2 24 Window Rear (South) 18.0 0.460 0.37 180 90 Summit 5500 Al DP Low E Zone 2 25 Window Rear (South) 13.5 0.460 0.37 180 90 Summit 5500 Al DP Low E Zone 2 26 Window Rear (South) 6.0 1.280 0.80 180 90 Summit 5500 Al DP Low E Zone 2 27 Skylight Front (North) 0.6 0.710 0.50 0 0 Solatube Zone 3 28 Skylight Front (North) 0.6 0.710 0.50 0 0 Solatube Zone 3 29 Skylight Front (North) 0.6 0.710 0.50 0 0 Solatube Zone 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Scre n 0.76 7 Bug Scre n 0.76 8 Bug Screen 0.76 8.0 5.0 10.0 0.1 10.0 10.0 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 18 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 19 Bug Screen 0.76 3.0 6.0 10.0 0.1 10.0 10.0 20 Bug Screen 0.76 3.0 6.0 10.0 0.1 10.0 10.0 21 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 22 Bug Scre n 0.76 8.0 6.0 10.0 0.1 10.0 10.0 23 Bug Screen 0.76 3.0 6.0 10.0 0.1 10.0 10.0 24 Bug Screen 0.76 3.0 6.0 10.0 0.1 10.0 10.0 25 Bug Screen 0.76 4.5 3.0 6.0 0.1 6.0 6.0 26 Bug Screen 0.76 2.0 3.0 6.0 0.1 6.0 6.0 27 None 1.00 28 None 1.00 29 None 1.00 I EnergvPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 10 of 29 1 Computer Method Summary (Part 2 of 3) C -2R CASA ESTELLA 12/17/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments -M Sky1ght Front rth) 0.6 0.710 0 50 0 f) Solatube Zone 3 31 Skylight Front (North) 0.6 0.710 0.50 0 0 Solatube Zone 3 32 Skylight Front (North) 0.6 0.710 0.50 0 0 Solatube Zone 3 33 Skylight Front (North) 0.6 0.710 0.50 0 0 Solatube Zone 3 34 Window Front (Northeast) 18.0 0.460 0.37 45 90 Summit 5500 Al DP Low E Zone 3 35 Window Left (East) 13.5 0.600 0.37 90 90 Summit 5500 Al DP Low E Zone 3 3fi Window Left (East) 3.6 0.460 0.37 90 90 Summit 5500 Al DP Low E Zone 3 37 Window Front (North) 27.0 0.600 0.37 0 90 Summit 5500 Al DP Low E Zone 3 ,$ Window Front (North) 3.6 0.460 0.37 0 90 Summit 5500 Al DP Low E Zone 3 3R Window Right (West) 6.0 0.460 0.37 270 90 Summit 5500 Al DP Low E Zone 3 40 Window Right (West) 6.0 0.610 0.39 270 90 Summit 5500 Al DP Low E Zone 3 41 Window Right (West) 6.0 0.610 0.39 270 90 Summit 5500 Al DP Low E Zone 3 A2 Window Right (Wes) 30.0 0.610 0.39 270 90 Summit 5500 Al DP Low E Zone 3 43 Window Front (North) 9.0 0.620 0.38 0 90 Glass Block Zone 3 44 Window Right (West) 9.0 0.620 0.38 270 90 Glass Block Zone 3 45 Window Right (West) 6.0 0.460 0.37 270 90 Summit 5500 Al DP Low E Zone 3 46 Window Rear (South) 30.0 0.460 0.37 180 90 Summit 5500 Al DP Low E Zone 3 47 Window Rear (South) 36.0 0.610 0.39 180 90 Summit 5500 Al DP Low E Zone 3 4$ Window Left (East) 48.0 0.740 0.37 90 90 Summit 5500 Al DP Low E Zone 3 49 Window Left (East) 6.0 0.460 0.37 90 90 Summit 5500 Al DP Low E Zone 3 50 Window Left (East) 24.0 0.740 0.37 90 90 Summit 5500 Al DP Low E Zone 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 30 None 1.00 31 None 1.00 32 None 1.00 33 None 1.00 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 11 of 29 1 Computer Method Summary (Part 3 of 3) C -2R CASA ESTELLA 12/17/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Minimum Distribution Type Area Thick. Heat and Location Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. Heavyweight —0 150 _28 0.98 n/a —9 Zone 1 / Slah nn Grade Concrete, Heavyweight 789 3_50 28 0_98 n/a 0 Zone 1 / Slab on Grade Concrete Heavyweight 216 3.50 _2fl. 0.98 n/a 2 Zone 2 / Slab on Grade Concrete. Heavyweight 1.055 3_50 28 0_98 n/a 0 Zone 2 / Slab on Grade ConcreteHeaiWyeight 1.543 3.50 —$ 0.98 n/a —2 Zone 3 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 96 0.76 0.0 0 Zone 1 Slah Perimeter 6.6. 0.76 0.0 _Q Zone 1 Slab Perimeter 102 0.78 0.0 0 Zone 2 Slab Perimeter 15 0.76 2Q _Q Zone 3 Slah Perimeter 180 0.76 0.0 0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFKducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 2 Central Furnace 80° AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 3 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump,. evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEEK Ducts in Attic 4.2 Setback HVAC System - Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System - Zone 2 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System - Zone 3 WATER HEATING SYSTEMS Rated/ Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -75-230 Small Gas Recirc/Demand _ 1 75 400 75 0.52 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 12/17/04 09:12:27 Run Code: 1103303547 EnerayPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 12 of 29 Computer Method Summary (Part 3 of 3) C -2R CASA ESTELLA 12/17/2004 Project Title . Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete HeamMight 472 3.50 98 0 A n/a —n Zone 3 / Slah on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFKducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location I heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 12/17/04 09:12:27 Run Code: 1103303547 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 13 of 29 Computer Method Summary (Addendum) C -2R CASA ESTELLA 12/17/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. ---PIan7 Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 0 sqft Covered Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 789 sqft Exposed Slab Floor, 3.50" thick at Zone 1 The HVAC System "HVAC System - Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 216 sqft Covered Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1055 sqft Exposed Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1543 sqft Covered Slab Floor, 3.50" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 472 sqft Exposed Slab Floor, 3.50" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC System - Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System - Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System - Zone 3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 12/17/04 09:12:27 Run Code: 1103303547 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 14 of 29 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 77] PROJECT NAME DATE CASA ESTELLA 12/17/2004 SYSTEM NAME FLOOR AREA HVAC System - Zone 1 789 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sgft) 1 44.4 Cooling System Output per System 35,200 Total Output (Btuh) 35,200 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 44.6 Total Output (sqf fron) 269.0 Air System CFM per System 855 Airflow (cfm) 855 Airflow (cfm/sgft) 1.08 Airflow (cfm/Ton) 291.5 Outside Air N 0.0 Outside Air (cfm/sgft) 0.00 Vote: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 of 69.4 of 69.4 of Outside Air O 0 cfm Supply Fan 855 cfm 69.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent H CFM I Sensible 290 8,974 0 287 11,378 0 449 569 0 0 0 0 0 0 0 0 0 4491 1 569 9,8 0 12 516 YORK H4DH036S06 27,366 0 35,000 Total Adjusted System Output 27,366 0 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am earn Temaeratures at Time of Heatina Peak) 107.8 of Heating Coil >% Return Air Ducts "I Supply Air Ducts 107.2 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 177.6 of 74.5 / 56.1 of 74.5 / 56.1 of 44.4 / 42.9 of Outside Air 0 Supply Air Ducts 0 cfm Supply Fan Cooling Coil 44.9 / 43.2 of 855 cfm 30.7% R.H. ROOMS 74,5/56.1 of 74.0 ! 55.9 of o a.._. A:_ �. U .. .. EneravPro 3.1 By EneravSoft User Number: 5454 Job Number: 3.1-1316 Paae:15 of 29 IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE CASA ESTELLA 12/17/2004 SYSTEM NAME FLOOR AREA HVAC System - Zone 2 1,271 Number of Systems 1 Heating System Output per System 75,000 Total Output (Btuh) 75,000 Output (Btuh/sgft) 59.0 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 46.0 Total Output (sgftrron) 260.7 Air System CFM per System 855 Airflow (cfm) 855 Airflow (cfm/sgft) 0.67 Airflow (cfmrron) 175.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensible Latent CFM I Sensible 754 15,253 0 499 18,594 0 0 cfm Supply Fan Heating Coil 855 cfm 763 930 0 0 0 0 0 0 0 0 0 763 930 16,7 0 YORK H4DHO60SO6 45,853 3,401 Total Adjusted System Output 45,853 3,401 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 75,000 75,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F Outside Air 69.0 OF 69.0 OF 105.0°F 0 Supply Air Ducts 0 cfm Supply Fan Heating Coil 855 cfm 104.0 of ROOMS 70.0 of 69.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF Outside Air 74.8/61.3OF 74.8/61.3OF O 55.0/53.9OF Supply Air Ducts 0 cfm Supply Fan Cooling 855 cfm Coil 55.8 / 54.2 OF 47.7% R.H. ROOMS 74.8/61.30F 74.0/61.0 OF EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 16 of 29 iVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE CASA ESTELLA 12/17/2004 SYSTEM NAME FLOOR AREA HVAC System - Zone 3 2,015 Number of Systems 1 Heating System Output per System 75,000 Total Output (Btuh) 75,000 Output (Btuh/sqft) 37.2 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 29.0 Total Output (sgft/Ton) 413.3 Air System CFM per System 855 Airflow (cfm) 855 Airflow (cfm/sqft) 0.42 Airflow (cfm/Ton) 175.4 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airs, 26.0°F 68.8 OF 68.8 OF Outside Air 0 cfm 68.8 of C 11.0 / 77.6 of Outside 0 cfm 75.0 / 51.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent 1, CFM I Sensible 404 19,083 0 261 22,219 0 954 1,111 0 0 0 0 0 0 0 0 0 954 1,111 _20,99 OI 2474411 YORK H4DHO60SO6 42,286 0 75,000 Total Adjusted System Output 42,286 0 75,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am am Tei 151.2 of Supply Fan Heating Coil 855 cfm K Return Air Ducts 4 75.0/51.0OF 75.0/51.OoF = 28.6/26.70F Supply Fan Cooling Coil 855 cfm h Return Air Ducts `S Supply Air Ducts 150.0 of ROOMS 70.0 of Supply Air Ducts 29.6 / 27.4 OF 14.4% R.H. ROOMS 74.0 / 50.5 of I EneravPro 3.1 By EneravSoft User Number: 5454 Job Number: 3.1-1316 Paoe:17 of 29 1 ROOM LOAD SUMMARY PROJECT NAME CASA ESTELLA DATE 12/17/2004 SYSTEM NAME HVAC System - Zone 1 FLOOR AREA 789 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 290 8,974 0 290 8,974 0 287 11,378 PAGE TOTAL 1 2901 8,974 oil 2871 11,378 TOTAL 1 290 8,974 0 287 11,378 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Pagel8 of 29 ROOM LOAD SUMMARY PROJECT NAME CASA ESTELLA DATE 12/17/2004 SYSTEM NAME HVAC System - Zone 2 FLOOR AREA 1,271 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 754 15,253 0 754 15,253 0 499 18,594 PAGE TOTAL 754 15,253 0 499 18,594 TOTAL 1 754 15,253 0 499 18,594 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Pagel9 of 29 IROOM LOAD SUMMARY PROJECT NAME CASA ESTELLA DATE 12/17/2004 SYSTEM NAME HVAC System - Zone 3 FLOOR AREA 2.015 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Zone 3 1 404 19,083 0 404 19,083 0 261 22,219 PAGE TOTAL 1 4041 19,083 0 261 22,219 TOTAL 1 404 19,083 0 261 22,219 EnergyPro 3.1 By Energysoft User Number: 5454 Job Number. 3.1-1316 Page:20 of 29 ROOM HEATING PEAK LOADS -71 Project Title Date CASA ESTELLA 112/17/2004 Room Information Desi n Conditions Room Name zone 1 Time of Peak Jan 12 am Floor Area 789 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 788.4 X X x X X x X X X X x X X X X X X X X X X X X x X x x X x x X X X X X x x X X 0.0280 X X x X X x X X X X X X X X X X X X X X X X X X X x X x x X X X X X X X X X X 44.0 = = = = = = = = = = = = 971 0.6 0.7100 44.0 19 perimeter = 92.4 44.5 4,112 245.0 0.0655 44.0 706 20.0 0.3872 44.0 341 496.7 0.0453 44.0 990 27.0 0.6000 44.0 713 64.0 0.7400 44.0 2,084 0,4600 44.0 1,443 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11 378 Infiltration: r 1.001 X 1.064 X 789 X 10.00 x 60] X LT _ �0 schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,378 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 21 of 29 ROOM HEATING PEAK LOADS Project Title Date 7 CASA ESTELLA 12/17/2004 Room Information Desi n Conditions Room Name Zone 2 Time of Peak' Jan 12 am Floor Area 1,271 Outdoor Dry Bulb Temperature 260E Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�T0F Btu/hr Summit 5500 Al DP Low E 1271.0 X x x x x x X X x X x X X x x x x x x x x x x x x x x X x x x x x X X X X X X 0.0280 X x X X X X X X X X x X X x X x x x x x x x x x x x X X X x X x x x x x x X x 44.0 = = = = = = = = = = = = 1,566 perimeter = 102.1 44.5 4,543 597.5 0.0453 44.0 1,191 18.0 0.6000 44.0 475 161.5 0.4600 44.0 3,269 28.0 0.3872 44.0 477 18.0 0.6100 44.0 483 192.0 0.7400 44.0 6,252 1,2800 44.0 338 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 18 594 Infiltration: r 1 .001 x Sensible x 1 271 X 10.00 x 60]x &T = Q schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 18,594 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 22 of 29 ROOM HEATING PEAK LOADS 7771 Project Title Date CASA ESTELLA 12/17/2004 Room Information Desicin Conditions Room Name zone 3 Time of Peak Jan 12 am Floor Area 2,015 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr IR -19 Wall w/1" EPS I 2,010.8 X X X X X x X X X X x X x x x x X x x X X x X x x X X x x X x x X x x X x x X 0.0280 X X X x X X X X X X x x x x x x X X x x x x x x x x x X X X x X x x X x X x X 44.0 = = = = = = = = = = = = 2,478 4.2 0.7100 44.0 131 perimeter = 194.9 44.5 8,673 1,516.3 0.0453 44.0 3,023 73.2 0.4600 44.0 1.482 40.5 0.6000 44.0 1,069 78.0 0.6100 44.0 2,094 18.0 0.6200 44.0 491 151.0 0,0655 44.0 435 72.0 0.7400 2,344 Items shown with an asterisk ('r) denote conduction through an Interior surface to another room. Page Total: I 22,2191 Infiltration: 1.00 x 1.064 x 2 015 X 10.00 X 6] x 0 = 0 chedule Alr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 22,219 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 23 of 29 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASA ESTELLA 12/17/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X DETD1 55.0 38.0 34.6 34.6 34.6 38.0 8. 38.0 Zone 1 740F 112°F 380E Btu/hr 1,214 16 555 268 779 616 1,800 1,246 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (')denote conduction through an interior surface to another room. 6 a9a Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btulhr Sk i ht 0" Dia (Skylight) 1 (East) Window 3080 FR DR (East) Window 2046 SH (South) Window 6646 FO (South) Window 2046 SH Window 1060 7 FO (South) (South) Window 2680_(2) FR DR (West) 73 0.41 ( 0.0 x x x x X x x X x x 1 + + + + + + + + + + 0.6 X X X X X X X x x x 152 ) X )x )x x X )X )x 0.57 = = = = = = = = = = 52 ( 0.0 1 9.0 73 0.41 271 ( 0.0 1 24.0 73 0.412 722 ( 0.0 1 9.0 32)X 0.412 119 ( 0.0 1 29.3 32) 0.412 386 ( 0.0 1 9.0 32)x 0.412 119 ( 0.0 1 42.0 32) 0.412 554 ( 39.5 1" 0.5 73)x 0.412 259 ( ( Sched. Page Total 2 a81 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 789 X 0.000 Wafts/sgft x 3.41 Btuh/Watt = 0 Occupants 1.00 X 789 x 9 Btuh/occ. / 20.00 sgft/occ. = 0 Receptacle 1.00 x 789 x 0.000 Wafts/sqft x 3.413 Btuh/Waft - 0 Process 1.00 x 789 x 0.000 Wafts/sgft x 3.413 Btuh/Watt = 0 Infiltration: x � x � x x � / 60] Z _ chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,974 Sched. Latent Gain Frac. Area Heat Gain Btu/hr OCCu ants 1.00 x 789 x 0 Btuh/occ. / 20 000 sgft/occ. = 0 Receptacle 1.00 x 789 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x 789 x 0.000 Watts/sqft x 3.41 Btuh[Watt = 0 Infiltration: 1 1.001 x 4 77 x 78 x Heigh x 60] 0.00000 = chedule Air Latent Area Ceiling Height ' ACH 1n1yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 By Energ Soft User Number: 5454 Job Number: 3.1-1316 Pa e:24 of 29 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASA ESTELLA 12/17/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 2 740F 112°F 380F Conduction Area U -Value DETD 1 Btu/hr X X X X X X X 55.0 = = = = = = = 1,958 34.6 937 38.0 410 38.0 2,823 34.6 375 38.0 417 1 38.01 5.399 X X 1. Design Equivalent Temperature Difference (DETD) Page Total 12 611 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 3060 SH Window 1rRQ (9) FO (North) (North) Window 3020 i3i FO (North) Window 1/2 Rd 2626 (Northeast) Window 1/2 Rd 3636 FO (North) Window 2 Rd 2626 _(Northwest) Window 3060 XO (North) Window 3020 FO (North) Window 3080 2 FR DR (South) Window 3080 2 FR DR South ( 0.0x1 X x x x x X + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 18.0x X x x x x x 15)X x X ) x 0.41 = = = = = = = = _ = 'l ( 0.0 36.0 15) 0.41 222 ( 0.0x 18.0x 15)X 0.41 111 ( 0.0x 5.6X 48)x 0.41 111 ( 0.0 4.8 15)x 0.41 30 ( 0.0x 5.6X 48)X 0.41 111 ( 0.0 18.0 15) 0.434 117 ( 0.0 6.0 15)X 0.41 37 ( 48.0 0.0 32)x 0.41 297 ( 48.0 0.0 32 0.41 297 Sched. Page Total 1 443 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,271 x 0.000 Wafts/sgft x 3.41 Btuh[Watt = 0 Occupants 1.00 x 1.27 x 0 Btuh/occ. / 20.00 sgft/occ. = 0 Receptacle 1.00 x 1,27 x 0.000 Wafts/sgft x 3.413 Btuh/Waft = 0 Process 1.00 X 1,271 xl 0.000 Wafts/sqft X 3.413 Btuh/Waft = o Infiltration: �� x Airs x Area 27 1 x Ceiling� x ACH / 60] 1 nT 38 _01 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,253 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1271 x 0 Btuhlocc. l 20 00o sqftlocc. = 0 Receptacle 1.00 x 1 271 x 0.000 Wafts/sqft X 3.41 BtuhlWaft = o Process 1.00 x 1 2 1 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = 0 Infiltration: chadulle x Air Latent x Area 27 x Ceiling Height x ACH 00 / 60] 1n1 OA0000 = Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1316 Page:25 of 29 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASA ESTELLA 12/17/2004 Project Title Date Room Name Zone 2 Design Indoor Dry Bulb Temperature: 740F Design Outdoor Dry Bulb Temperature: 1 120F Design Temperature Difference: 380F Conduction Area U -Value X 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (`) denote conduction through an interior surface to another room. o Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 6030 FO (South) W*nrInvv 6030 170 (South) Window 3080 2 FR DR (South) Window 3080 2 FR DR (South) Window 6030 FO (South) Window 6030 FO (South) Window 3046 FO (South) Window 3020 FO (South) 0.0 32 0.412 297 ( 18.0x x X x x X x x x X 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + + + 0.0x X X X X X x x x x 32)X ) x x x )x )x 0.41 = = = = = = = = = =_ 111 ( 18.0 0.0 32)x 0.412 111 ( 48.0 0.0 32 0.412 297 ( 48.0 0.0 32) 0.412 297 ( 18.0 0.0 32)x 0.412 111 ( 18.0 0.0 32)x 0.412 111 ( 13.5 0.0 32)x 0.412 83 ( 6.0 0.0 32) 0.856 77 ( ( Sched. Page Total 1 198 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,271 x O-OOC Watts/sqft x 3.41 Btuh/Watt - 0 Occupants 1.00 x 1,27 x Btuh/occ. / 20 000 sgft/occ. = 0 Receptacle 1.00 x 1,27 x 0.00 Watts/sgft x 3.413 Btuh/Waft = 0 Process 1.00 x 1,271 x 0.00 Wafts/sqft x 3.41 Btuh/Waft = 0 Infiltration: �� x Sensible x 1,271 x x � / 60� _ Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,253 Sched. Latent Gain Frac. Area Heat Gain Btu/hr OCCU ants 1.00 X 1 271 x 0 Btuh/occ. I 20 000 sgft/occ. = 0 Receptacle 1.00 x 1 271 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = 0 Process 1.00 x 271 X 0.000 Wafts/sqft X 3.41 Btuh/Waft = 0 Infiltration: �ohetool ie x L 4,77q Air Latent x Area 27 X Ceiling Height x ACH 00 / 60] QOtON0000 = Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1316 Page:26 of 29 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASA ESTELLA 12/17/2004 Project Title Date Room Name Zone 3 Design Indoor Dry Bulb Temperature: 740F. Design Outdoor Dry Bulb Temperature: 1 120F Design Temperature Difference: 380F Conduction Is Area U -Value X DETD 1 X 55.0 X 38.0 X 34.6 X 38.0 X 38.0 X 38.0 X X X Btu/hr 3,097 113 2,377 1,280 923 1,808 424 1. Design Equivalent Temperature Difference (DETD) Page Total 12 389 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Skylight 10" Dia (Skvlight) _ (Skylight) Sk i ht 10" Dia (Skylight) Skylight 10" Dia (Skylight) Skylight 10" Dia (Skylight) Sk i ht 10" Dia (Skylight) Skylight 10" Dia (Skylight) Window 1060 3 FO Northeast Window 3046 SH (East) Window 1/2 Rd 3016 FO East ( 0.0 x x x x X x x x X X 1 + + + + + + + + + + 0.6 x X x x x x X X X x 152) X x ) X x X X X x 0.57 = = = = = = = = __ = 52 ( 0.0 1 0.6 152) 0.57 52 ( 0.0 1 0.6 152 0.575 52 ( 0.0 1 0.6 152)x 0.57 52 ( 0.0 1 0.6 152) 0.575 52 ( 0.0 1 0.6 152) 0.57 52 ( 0.0 1 0.6 152) 0.575 52 ( 0.0 1 18.0 48) 0.41 356 ( 0.0 1 13.5 73)x 0.412 406 ( 0.0 1 3.6 73) 0.41 108 Sched. Page Total 1 237 Internal Gain Frac. Area Heat Gain Btu/hr Licihts 1.00 X 2,015 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Occupants 1.00 X 2,015 x 0 Btuh/occ. / 20.00 sqft/occ. = 0 Receptacle 1.00 x 2,015 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 2,015 x 0.000 Watts/sgft x 3.41 Btuh[Watt = 0 Infiltration: L d_0o1 x�rs� x x ensible Area Coiling x 60] / 38 = Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,083J Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2 015 x 0 Btuh/occ. / 20 000 sgft/occ. = 0 Receptacle 1.00 x 2 015 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Process 1.00 x 2 015 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Infiltration: Fi= oo x ule Air ni x Areao1 X Ceiling Height x ACH 00 / 60] Qo100000 ScheN= Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 By Energ Soft User Number: 5454 Job Number: 3.1-1316 Page:27 of 29 RESIDENTIAL ROOM COOLING LOAD SUMMARY CASA ESTELLA 12/17/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X X X X X X X X DETD1 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Zone 3 740F 112°F 380E Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 3046 2 SH (North) 1 + 1 + 1 + 1 + 1 + + (North) Window 1016 4 FO (West) Window 3020 XO (West) Window 3020 XO (West) Window 6050 XO (West) Window 3030 GL BLK (North) Window 3030 GL BLK (West) Window 1016 4 FO (West) Window 1060 5 FO South ( 0.0x x x X x+ x+ Xdi X+ 1 + 1 + 1 + 1 + 1 + + 27.0x X X X X x x x 15)X ) X x x ) x 0.41 = = = = = = = = __ = 167 ( 0.0x 3.6X 15)x 0.412 22 ( 0.0 6.0 73 0.412 180 ( 0.0 6.0 73)x 0.434 190 ( 0.0 6.0 73) 0.434 190 ( 0.0 30.0 73)X 0.434 951 ( 0.0 9.0 15) 0.423 57 ( 0.0 9.0 73)x 0.423 278 ( 0.0X+ 6.0X 7)x 0.41 180 ( 0.0 30.0 32 0.412 395 Sched. Page Total 2 611 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 2,015 x 0.00C Watts/sqft xA3.413 Btuh/Watt = 0 Occupants 1.00 x 2,015 x Btuh/occ. / sgft/occ. = 0 Receptacle 1.00 x 2,015 x 0.00 Watts/sqft x Btuh/Waft = 0 Process 1.00 x 2015 x 0.00 Wafts/sgft XBtuh/Watt = 0 Infiltration: S� x Air Sensible � x Area 2,015 x Coiling � x ACH / 60] nJ _ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,083 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2 015 x 0 Btuh/occ. / 20.00 sgft/occ. = 0 Receptacle 1.00 x 2 015 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process 1.00 x 2 015 x 0.000 Wafts/sgft x 3.4d Btuh/Waft = 0 Infiltration: F 1.00 x 4 77 x 2 01 x 10.00 x 0.00 / 60] 0.00000 Schedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1316 Pa e:28 of 29 It RESIDENTIAL ROOM COOLING LOAD SUMMARY CASA ESTELLA 12/17/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 3 740E 112°F 380F Conduction Area U -Value DETD' Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 6060 XO (South) ( 0.0 x 11 + 36.0 x 32 )x 0.434 = 500 Winclaw'408f) (9) FIR nR (East) ( 0.0 x 1 + 48.0 x 73 ) x 0.41 = 1,443 Window 1016 4 FO (East) ( 0.0 x 1 + 6.0 x 73 ) x 0.412 = 180 Window 3080 FR DR (East) ( 0.0 x 1 + 24.0 x 73)x 0.412 = 722 ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = ( X + X )x = Sched. Page Total 2845 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 2,015 X 0.000 Watts/sgft xA3.41 Btuh/Waft = 0 Occupants 1.00 X 2,015 X Btuh/occ. / sqft/occ. = 0 Receptacle 1.00 x 2 015 x 0.00 Watts/sqft x Btuh/Watt = 0 Process r 1.00 x 2,015 x 0.00 Watts/sgft XBtuh/Wlatt = o Infiltration: I en� x Airs x LArea -2.015) x Coiling� x ACH / 60] en3BJ = Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,0831 Sched. Latent Gain Frac. Area Heat Gain Btulhr Occupants 1.00 X 2 015 x 0 Btuh/occ. / 20 000 sgft/occ. _ Receptacle 1.00 X 2 015 x 0.000 Wafts/sgft x 3.4 BtuhlWaft = o Process 1.00 x 2 015 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o Infiltration: tool oo x Air Latent X Areao1 X Calling Height x ACH 00 / 60] ootON0000 = 0 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Ener Pro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1316 Page: 29 of 29