Loading...
BRES2017-0115 Revision 1 Structural CalcsTTAl H AC)T . �� E'L�I;��ING J Ire, �CL 77570 Springfield Lane, Suite "D" Palm Desert, CA 92211 �VISIGN � 1 R�s2oi �- o� 15 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 112 !f17 8V '* VeVrA 2i 3 4 j INu.vcEfl I N -rrhS Structural Calculation For Dahlberg Residence At 53-810 Del Gato Drive The Tradition La Quinta, CA Of Project: Residential Remodel/Addition Rev. #2 (08/07/2017) Designer: Ochoa Design Associates Date: May 11, 2017 Design by: R.A. JN: 170458 Telephone: (760) 360-9998 Fax: (760) 360-9903 �SGHAp-aO� NO. C67613 E x P. bL 6 0 4S7r12 / V0>111 STRUM'L RAI, ENGINEERING, INC. NOTE FOR SLAB: 4" CONCRETE SLAB WITH #3 REBARS @ 18" O/C EACH WAY. OVER 2" CLEAN SAND OVER 10 MIL VISQUEEN VAPER BARRIER OVER 2" CLEAN SAND OVER 90% COMPACTED FILL. SHEET: PARTIAL FOUNDATION JOB NO.: 170458 DATE: 08/07/2017 (Rev. #2) CLIENT: DAHLBERG RESIDENCE 1 z 22 s01 FX SD1 5 23 5 HFX 18x 10 i rS D 1 HS i (N) 16 I I 8'-6"X2'-6"X24" G. BM I I) SD1 15 W/(4) #5 & (4)#5SD1 PAST PAN(EL) -6" 4 E/W 5D1 , ..,.� SD1 i SD1 (E) PADS r — L (E) FOOTING (W.F. PARTIAL FOUNDATION DAHLBERG RESIDECNE UY i 5 �. (E ;.. i � ..�1 (V.I.F.] i ........................... _ E I (E) W 12X40 STEEL COL. ' � I � I I (E) PAD —` i piROFE5S1�4, Q I,SGHAR rr W. C67613 SCALE: 1 /4"= I'-0" �t� IS ELEC'RONIC,,1,IIATURE STRUCTURAL TURAL ENGINEERING, INC. SHEET: PARTIAL FRAMING JOB NO.: 170458 DATE: 08/07/2017 (Rev. #2) CLIENT: DAHLBERG RESIDENCE L G `7 FX 5D3 LOW 5D3 HDR 5D3 �J Q HFX 18x 10 5�3 � : 1 HS `� - - - - Crib - (N) �Ff--- N 8 Q J.� .. (E) BM .. — ......... .. _ ... _ . 625 m L N N m rl E3 sDz I I x�l � 12 z mom10 CS14 I S13 E2 LOW 19A I 15D3}� 12 10 ` {E) BM _ - - - - - SD2 SD3 3 (Fj,�Or_.. _._-.5DSQ2 — — SIM. (E) BM [V.I.F.] _f • �� (N) i 20C ... .............. - .... ,..... i �D3(E) W 12X40 1c El ��' STEEL COL. S D A ECC ,{ HIGH SD2 { LOW 10 SD2 V �SGHA ti NC. C67613 PARTIAL FRAMING DAHLBERG RESIDECNE SCALE: 1 /4"= I'-0" 'THoS IS ELECTRONIC F. SriskiUCTURAL ENGINEERING, INC. SHEET: DETAIL 25/SD3 JOB NO.: 170458 DATE: 08/07/2017 (Rev. #2) CLIENT: DAHLBERG RESIDENCE SIMPSON ST6236 STRAP EACH SIDE I �r 0 0 0 00 0 0 u 0 0 0 0 0:0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 00 0 0 0 0 0 0 CONNECTION DETAIL SCALE: NTS POST PER PLAN 2x TRIMMER PLATES Q pSGH4pw 9• QNO. C 67613 w 25 r E' 0 S D 3) N� ORILS IS 2EC TP,IlN . !GNAT E STRUCTURAL ENGINEERING, INC.. SHEAR WALL LAYOUT Uf SHEET: SW -LAYOUT JOB NO.: DATE: CLIENT: DAHLBERG RESIDENCE J RA Structural DESIGNED R.A. JOB NO. 170458 S'I'kl'C'f IIRU. ENGl1(rk11G. J.R PROJECT Dahlberg Residence CHECKED R.A. SHT OF SUBJECT Remodel/Addition DATE 05/11/2017 Shear line reactions and shear wall forces Floor ID: 1st Shear line ID Reaction (Ibs) Seismic Wind Shear wall ID Shear wall forces (Ibs) Seismic Wind R* Wall type 1 802 792 1-1 381 479 6.50 Pre -manufactured 2 1707 1554 2-1 863 932 6.50 Pre -manufactured 3 2450 1450 3-1 2450 1450 6.50 Not Designed 4 2022 1861 4-1 12022 1 1861 6.50 Segmented 5 1726 2078 5-1 1726 2078 6.50 Segmented 6 2836 0 6-1 2836 0 6.50 Not Designed 7 8 2922 2592 2301 1645 7-1 8-1 2922 2592 2301 1645 6.50 6.50 Segmented Segmented 9 2068 1650 9-1 2068 1650 6.50 Not Designed 10 1975 1283 10-1 1608 673 6.50 Pre -manufactured 11 12380 2889 11-1 2380 2889 6.50 Not Designed 12 379 630 12-1 379 630 6.50 Pre -manufactured 13 513 81 13-1 513 81 6.50 Not Designed 14 2508 3658 14-1 14-2 865 1643 1261 2396 6.50 6.50 Segmented Segmented 15 j 1060 1281 15-1 1060 1281 6.50 Not Designed 16 12363 1821 16-1 2363 1821 6.50 Segmented 17 1161 0 17-1 161 0 6.50 Not Designed 18 11681 2019 18-1 1681 2019 6.50 Segmented 19 161 0 19-1 161 0 6.50 Not Designed 20 1481 1153 20-1 1481 1153 6.50 Not Designed 21 465 1006 21-1 465 1006 6.50 Segmented a 272 429 a-1 272 429 6.50 Segmented b 1108 1505 b-1 257 0 6.50 Pre -manufactured c 1769 497 C-1 c-2 742 700 204 194 6.50 6.50 Pre -manufactured Pre -manufactured d 2328 0 d-1 2328 0 6.50 Segmented e 993 134 a-1 1993 134 16.50 Not Designed f 445 532 f-1 445 532 6.50 Segmented g 3063 64 g-1 g-2 1250 1813 26 38 6.50 6.50 Segmented Segmented h 1599 878 h-1 h-2 799 799 439 1439 6.50 6.50 Segmented Segmented i 1635 1 1437 i-1 1635 11437 6.50 Segmented 1 3239 256 j-1 3239 256 6.50 Not Designed k 5747 314 k-1 5747 314 6.50 Not Designed 1 1731 2210 1-1 1731 2210 6.50 Segmented m 2638 1697 m-1 m-2 m-3 465 407 1765 385 1337 1975 6.50 6.50 6.50 Shear wall with opening Shear wall with opening Not Designed www.structuralsoft.com CLIENT: Dahiber Rai Pn(e RA Structural En ineering, Inc. SHEET: SUBJECT: Q� rn o�Qi - .....—. JOB NO:I-7�2�58 DESIGN BY:DATE: ogiMll L,w,I pad on gt4mP, 0 F = 21o a-? u Je Kf x l gxlQ Rf Fgl1�w��,1e = 2,bo5 Ac ? 2,07£? lis V/0'/ 0� PROJECT: Grade Beam(HFX18x10) PAGE: I lit-1.-I'VF�A1. CLIENT: Dahlberg Residence DESIGN BY: R.A. , -- =T.:LN 'INIEEIII�X JOB NO.: 170458 DATE: REVIEW BY: R.A. Footing Design of Shear Wall Based on ACI 318-14 INPUT DATA WALL LENGTH Lw = 1.5 ft WALL HEIGHT h = 10 ft WALL THICKNESS t = 4 in FOOTING LENGTH L = 8.5 ft L, = 3.5 ft FOOTING WIDTH B = 2.5 It FOOTING THICKNESS T = 24 in FOOTING EMBEDMENT DEPTH D = 2.5 ft ALLOWABLE SOIL PRESSURE qa = 1.5 ksf DEAD LOAD AT TOP WALL Pr,DL = 0.1 kips, Wr,DL = LIVE LOAD AT TOP WALL Pr,LL = 0.1 kips, wr,LL = TOP LOAD LOCATION a = 0.75 ft WALL SELF WEIGHT Pw = 0.1 kips LATERAL LOAD TYPE (0=wind,1=seismic) 0 wind WIND LOADS AT WALL TOP (W, SD) Fu = 2.969 kips, SD Mu = 0 ft-kips, SD CONCRETE STRENGTH fc' = 2.5 ksl REBAR YIELD STRESS fy = 60 ksi TOP BARS, LONGITUDINAL 4 # BOTTOM BARS, LONGITUDINAL 4 # BOTTOM BARS, TRANSVERSE # 3 @ 20 plf 20 plf 4!r L i Pr _ _ o F rt 1 M h C P`'' 1 hr n I LI / L f (F = 2.12 kips, ASD) (M = 0.00 ft-kips, ASD) THE FOOTING DESIGN IS ADEQUATE. 5 5 12 in o.c. <== Not Required ANALYSIS CHECK OVERTURNING FACTOR (2015 IBC 1605.2.1, 1808.3.1, & ASCE 7-10 12.13.4) F = MR / Mo = 1.02 < 1.0 / 0.9 for wind Where Pr,DL = 0.13 kips, (total roof CL, including wr,DL) Pr,LL = 0.13 kips, (total roof LL, including wr,LL) a = 0.692308 ft, (total roof loads) Pf = 6.1625 kips (footing self weight) Mo = F (h + D) + M = 27 ft-kips (overturning moment) MR = (Pr,DL) (1-1 + a) + Pf (0.5 L) + Pw (1-1 + 0.51-w) = 27 CHECK SOIL CAPACITY (ALLOWABLE STRESS DESIGN) Ps = 4.25 kips (soil weight in footing size) P = (Pr,DL + Pr,LL) + Pw + (Pf - Ps) = 2.27 kips (total vertical net load) MR = (Pr,DL + Pr, LL) (Li + a) + Pf (0.5 L) + Pw (1-1 + 0.51-w) = 28 e = 0.5 L - (MR - Mo) / P = 3.72 It (eccentricity from middle of footing) PI I+ BL Le) L u• ii 6 fur e 5 qn�._ 2 P L, = 1.15 ksf foFe > - 3B(O.SL-e)' 6 Where e = 3.72 ft, > (L / 6) CHECK FOOTING CAPACITY (STRENGTH DESIGN) Mu,a = 1.2 IPr,DL (LI + a) + Pf (0.5 L) + Pw (1-1 + 0.51-w)] + 0.5 Pr, LL(Lj + a) Mu,o = 1.0 [F(h + D) + M] = 27 ft-kips = 33 ft-kips Pu = 1.2 (Pr,DL + Pf + Pw) + 0.5 Pr, LL = 8 kips eu = 0.51- - (Mu,R - Mu,o) / Pu = 3.43 ft P 6e„ L for e„5L q,,,,,,AX = BL 6 2.51 ksf 2 P„ L 3B(0.5L - e„) ' 6 ft-kips (resisting moment without live load) ft-kips (resisting moment with live load) < 4/3qa 0 qu,mo [Satisfactory] 0 (confd) BENDING MOMENT & SHEAR AT EACH FOOTING SECTION 20 15 10 5 0 -5 OM -10 20 0 -20 1 o V -40 Mu f 1 - ) - 0.383b�/2J� Where P- Pmin = 0.0018 0.85,8,.E Eta Pnin.r- , y . Eu+Et- 0.0129 [Satisfactory] Section 0 1/10 L 2/10 L 3I10 L 4I10 L 5I10 L 6/10 L 7/10 L 8110 L 9/10 L L Xu (ft) 0 0.85 1.70 2.55 3.40 4.25 5.10 5.95 6.80 7.65 8.50 Pu w (klf) 0.0 0.0 0.0 0,0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 Mu.w (R-k] 0 0 0 0 0 -13 -27 -27 -27 -28 -28 Vu,W (kips) 0 0 0 0 0 -27 0 0 0 0 0 Pu,f(ksf) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Mu,l (ft-k) 0 0 -1 -3 -5 -8 -11 -15 -20 -25 -31 Vu,f(kips) 0 •1 -1 •2 -3 -4 -4 -5 -6 -7 -7 qu (ksf) -2.5 -1.6 -0.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Mu,q (ft-k) 0 2 7 13 20 27 33 40 46 53 59 Vu,q (klps) 0 4 7 8 B 8 8 8 8 8 8 E Mu (ft-k) 0 2 6 11 15 5 -5 -3 -1 0 0 E Vu (kips) 0 4 6 6 5 -23 3 2 1 1 0 Location Mu.maz d (in) (OregD PprovD Vu,max �Vo = 2 � b d (f� )o.s Top Longitudinal -5 ft-k 20.69 0.0001 0.0020 23 kips 53 kips Bolcom Longitudinal 15 ft-k 20.69 0.0018 0.0020 23 kips 53 kips Bottom Transverse 0 ft-k / ft 20.19 0.0000 .. 0.0000 . 0 kips / ft 21 kips 1 ft t Rr j ,1-JRr UCj�-/UR2.r'3ll �-' C3FI�RR—/=V2 Aram INC, 77570 Springfield Lane, Suite "D" lelc:phone: (760) 360-9998 Palm Desert, CA 92211 Fax: (760) 360-9903 Structural Calculation For Dahlberg residence At 53-810 Del Gato Drive The Tradition La Quinta, CA 'Ivye Of Proiect: Residential Remodel/Addition Rev. #3 (08/21 /2017) Designer: Ochoa Design Associates Date: May 11, 2017 Design by: R.A. JN: 170458 RECEIVED 0 01 ZZ17 CM C5 L' QUIO A COMMu141V toF. ' - NO. C67613 5rrt I 1SZ STRUCTURAL ENGINEERING, INC. NOTE FOR SLAB: 4" CONCRETE SLAB WITH #3 REBARS @ 18" O/C EACH WAY. OVER 2" CLEAN SAND OVER 10 MIL VISQUEEN VAPER BARRIER OVER 2" CLEAN SAND OVER 90% COMPACTED FILL. N 8'-6"X2'-6"X24" G. BM W/(4) #5 & (4) #5 PAST PANEL 3'-6" E/W (N) HS I 11 SDI ELD _ (E)PADPAD - - (E) D1 3 r---------1— —_- -� + 5D1 I I I 16 I 4) 5 J _I �o (N) _I_ 7{E) HD10A ! I (E) W 12X40 �G (V.I.F.) (V) I 1 5TEEL COL. .1.F. I I (E) PAD- I + f ! ! f PARTIAL FOUNDATION vrin�atr�v IStJIUtIV�.t SCALE: 1 /4"= I'-0" SHEET. PARTIAL FOUNDATION JOB NO.: 170458 DATE: 08/21/2017 (REV#3) CLIENT: DAHLBERG RESIDENCE Al (N) - -- � sD1 j (N) HS r--- ----- - — — — — — — 1 — ! I 1 12 fl ' 5D1 7 SDII 8'-6'lX2'-6"X24" G. BM I I I W/(4) #5 & (4) #5 PAST PANEL 3'-6" Ej1A1 ypfl L — D I Il P3 1 it I '1 14 Il I SDI 24 I �I 10'-6"X2'-6"X24" G. BM f CBSQ GD 1 W/(4) #5 & (4) #5 I 1 Ir Z PAST PANEL 4'-3" E/W I SD1 I )i pROFE5S1� 1 p S L/ � No. cs7s� 3 ' STRUCTURAL ENGINEERING, INC. I SHEET: PARTIAL FRAMING PLAN JOB NO.: 170458 DATE: 08/21 /2017(REV#3) CLIENT: DAHLBERG RESIDENCE (V.I.F) 27 6 7 L I 24 5B FX 503 4 5D3 HD SD3 4 5D3 Q 5S 2 HFX 18x 10 56 �, 2 1 SD2 - - PSG SD2 SD2 SD2 HS 5D2 1 -- -- - (N) N 5 1 8" x 19 1/2"GLB 24F - V4 FL BM W/E.N, s - - - - ' — — �N� — bR — -- — T - - E 5 1/8" x 15" GLB 24F - V4 CLG Bps - - HU (N) (N)6X12 FL BM cQ HFX 18x 10 16 m B25 HS ` 5D3 LL ty 26 1O o n •� 0 FX SD3 E3 z =I I Sp3 co 19A R z SD2 w � G �I CS14 I (VEF' S0 E2 LOW HIGH m �o i I _ m w -- --- -- -- -- 12 4B _ D� 12 10 1 N (E) BM SD2 SD3 6�$ - �— SD3 502 SD2 00 x - SIM. `O Z lz (E) W 10X30 L STEEL CdE ' (E) BM r 5 HHU S '+ A REPLACE (2) EXISTING WOOD BEAMS W/ (1) NEW STEEL BEAM S I f 1 a a pf PARTIAL FRAMING DAHLBERG RESIDENCE SCALE: 1 /4"= r-0" HIGH LOW (N)5 1/8"X18" GLB 24F-V\l z8 B22 D3 (E) W 12X40 19 STEEL COL. Sp3 I ECCOL i I I W' m p�OFESS/p w Q pSGHAR,oaC SHEET; DETAIL 9/SD3 JOB NO.: 170458 DATE: 08/2112017 (Rev.43) CLIENT: DAHLBERG RESIDENCE SIMPSON ST6236 STRAP CENTERED @ SPLICE SIMPSON DSCS DRAG CONNECTOR — MIN. 6x12 r_ILLLR ■ u _ I BEAM PER PLAN (2) SIMPSON — HARDY FRAME ST6224 STRAP PANEL PER PLAN WOOD BEAM CONDITION RpFEiSiG. �Q.P aSGHg4,p'�( QN0. 3 C67613 m DETAIL l 9 EXP,. 06/30/19 -DRAG _ SCALE: NTS T SD3 F �f . Y STI � I "C" I'L I ZA f Kt\A&- !,\JGI\f:I:l:IN(1, INC. ROOF SI-IEATING_ EX SHEET: DETAIL 26603 JOB NO.. 170458 DATE: 08/21 /2017 (Rev. ft-3) CLIENT: DAHLBERG RESIDENCE SHEET: DETAIL 27/SD3 JOB NO.: 170458 DATE: 08/21 /2017 (Rcv. 43) CLIENT: DAHLBERG RESIDENCE ROOF SI-IEA'I ING 6x SOLID FILLER E. N. fV SI,MPSON LT['4-@ 48"_O/C ROOF 'TRUSS EA. SIDE FILLER TO BM CLG 13M, PER PLAN TRUSS BLOCKS _.._ wl 4t3" O/C W/E.N. ROf 5510 F FSCH,ggA^S'� ti��yF 09��'i A3 Q W, C67613 SHEAR TRANSFER DETAIL 2�. 27 CXP. O6/30/19 SCALE: NITS Page 4of4 STRUCTURAL E, NGINI� ERINK-3, INC. SHEET: DETAIL 28/SD3 JOB NO.: 170458 DATE: 08/21 /2017 (Rev. #3) CLIENT: DAHLBERG RESIDENCE (E) SHEAR PANEL TYPE 5 (V.I.F.) 4x6 W (2) ROWS 1/4" x 5" SDS SCREWS @ 4" O/C STAGGERED E.N. E.N. r I. (N) SHEAR E.N. h PANEL TYPE 5 (E) 6x6 POST pRpFl~Ssr��, O PSGH4,p Q.. tip 0 No, C67613ly- C O N N E N CT I O N DETAIL 28 EXP, 06/30/19 SCALE: NTS ❑ 3 OF �1F ZZ S'I RI C -11-] RAI., ENGINEERING. INC. SHEAR WALL LAYOUT u SHEET: SW -LAYOUT ;OB NO.: DATE: �Toyso 0912110017 CLIENT: DAHLBERG RESIDENCE 511 RA Structural DESIGNED R.A. JOB NO. 170458 rr�lsliii�r.rtc. PROJECT Dahlberg Residence CHECKED R.A. SHT OF SUBJECT Remodel/Addition DATE 05/11/2017 Shear line reactions and shear wall forces Floor ID: 1st Shear line ID Reaction (Ibs) Shear wall ID Shear wall forces (Ibs) R* Wall type Seismic Wind Seismic Wind 1 802 792 1-1 802 792 6.50 Pre -manufactured 2 1707 1554 2-1 1707 1554 6.50 Pre -manufactured 3 2450 1450 3-1 12450 1450 6.50 Not Designed 4 2022 1861 4-1 1726 2022 1861 6.50 Segmented 5 726 2078 5-1 2078 6.50 Segmented 6 2836 0 6-1 2836 10 6.50 Not Designed 7 2922 2301 7-1 12922 12301 6.50 Segmented 8 2592 1645 8-1 2592 11645 16.50 1 Segmented 9 2068 1650 9-1 12068 1650 6.50 Not Designed 10 1975 1283 10-1 1975 1283 6.50 Pre -manufactured 11 2380 2889 111-1 2380 2889 6.50 Not Designed 12 379 630 12-1 379 630 6.50 Pre -manufactured 13 513 81 13-1 513 81 6.50 Not Designed 14 2508 3658 14-1 865 1261 6.50 Segmented 14-2 1643 2396 6.50 Segmented 15 1060 1281 15-1 1060 1281 6.50 Not Designed 16 2363 1821 16-1 2363 11821 6.50 Segmented 17 161 0 117-1 161 10 6.50 1 Not Designed 18 1681 2019 18-1 1681 2019 6.50 Segmented 19 161 0 19-1 161 0 6.50 Not Designed 20 1481 1153 20-1 11481 11153 6.50 1 Not Designed 21 465 1006 21-1 465 1006 1429 6.50 Segmented a 272 429 a-1 272 6.50 Segmented b 1108 1505 b-1 1108 1505 6.50 Pre -manufactured c 1769 497 c-1 1062 298 6.50 Pre -manufactured c-2 708 199 6.50 Pre -manufactured d 2328 0 d-1 2328 0 6.50 Segmented e 993 134 e-1 993 134 16.50 Not Designed f 445 532 f-1 445 532 16.50 Segmented g 3063 64 g-1 1250 26 6.50 Segmented g-2 1813 138 6.50 Segmented h 1599 878 h-1 799 439 16.50 Segmented h-2 799 439 6.50 Segmented i 1635 1437 i-1 1635 1437 16.50 Segmented j 3239 256 j-1 3239 256 16.50 1 Not Designed k 5747 314 k-1 5747 1314 16.50 1 Not Designed 1 1731 2210 1-1 1731 2210 6.50 Segmented m 2638 1697 m-1 465 385 6.50 Shear wall with opening m-2 407 337 6.50 Shear wall with opening m-3 1765 975 6.50 Not Designed www.structuralsoft.com D 0 0 0 0 0 0 o T o T T T T T T :- - o o in o I? o in i- in i-- � co ao T N N � � T i N � M i U U o cm � L s E E c c c t ax VF)4 = %ig9Z AS xis► KAf d or,�r► HI)IM Od afi� g 90o & > 9, c 92165 f%k Anchors Ica® These products are available with additional Cori oslon protection. Additional products on this page pray also be available with this option, check with Simpson for derails. Material Dimensions Fasteners Model No. Base Body HB' SB W H B Stud So Anchor Machine Bolts Dia.6 Dty, Dia, Ye — 1'/16 i5v y 2 — Sin HD2A 7 12 49/16 2Yz 1 23/4 1 8� 2B/16 HD5A 3 10 51/4 3 31/a 91/16 3e//e Yz 23/16 Ra 2 3/4 HD6A 3/87 63/16 31/2 31/4 11Y1a Via B/ie 2'/ie 2 7/a H D8A 3/a 7 63/1 e— 3 Yz 3% 149/16 37/16 a/1 a 2 Y16 7/6 3 7/a HD10A 3/8 7 63/16 3'/z 31/4 18'/1e 37/1e %a 2Y1a 7/e 4 7/a HD14A 3/a 3 7 4 31/z 2011/16 35/e 5/e 23/1e 1 4 1 HD15 3/8 3 7 1 4 1 31/2 241/z 1 47/16 35/a 21/e 11/4 5 1 See notes below, Model No. Allowable Tension Loads DF/SP (133/160) Allowable Tension Loads SPF/HF (133/160) Holdown' Deflection at Highest Allowable Design Load Eiu;;il Holdown°,' Deflection a1 Highest Allowable Design Load Raised Code Ref. Wood Member Thickness _ Wood Member Thickness 1% 2 21/z 3 31h 41' 51/z 1'r4 2 2'h 3 3'h 5'r2 HD2A 1555 2055 2565 2775 2775 2775 2760 1320 1740 2165 2570 2565 :', .: 2550 0.058 0.077 HD5A 1870 2485 3095 3705 4010 1010 3980 1585 2110 2625 3130 3645 r'U 3680 1 0.067 0.117 HD6A 2275 2980 3685 4405 5105 54 1) 5510 1870 2470 3065 3680 4280 57r,5 5020 0.041 0.125 HD8A 3220 4350 5415 6465 7460 ;CES 7910 2710 3655 4530 5480 6350 :r, 0 7330 0.111 0.121 401225, HD10A 3945 5540 6935 8310 9540 ?"'; ;;9900 3275 4600 5745 7045 8160 : _ _9195 0.269 0.269 9495 12485 _ 0.215 0.282 HD14A — — — — 11080 , :. 13380 — — — HD15 — —» — — — ; :S 15305 — — — — — i i ..., 13810 1 0.082 0.082 1. Allowable loads have been Increased for earthquake or wind load durations with no further increase allowed; reduce where other load. durations govern. 2. HD15 requires a minimum 48 (in a XIV wide shearwall) or a 6xG nominal post to ensure the tension load carrying capacity of the critical net section meets the holdown capacity. 3. Use minimum 46 nominal post for the HD14A. Minimum post size is required to ensure the tension load carrying capacity of the critical net section meets the holdown capacity. 4. HB is the required minimum distance from the end of the stud to the center of the first stud bolt bolo. End dlslance may be Increased as necessary for installation. 5. The designer must specify anchor boll type, length and embedment - See SSTB Anchor Bolts (page 33-34) and Additional Anchor Designs rpage 34). 6. Refer to technical bulletin T-ANCHDASPEC for retrofit anchor soluliions (see page 199 for details). 7. Lag bolts will not develop the listed loads. 8. See page 13-15 for testing and other important information. 1. Bolt slip can occur at holdown stud bolts. 2. Increased bolt slip can occur if oversized holes are drilled through the stud for holdown stud bolts (oversized holes are when the hole diameter is greater than the bolt diameter plus %6" per 2001 NDS 11.1.2), 3, When a holdown is installed on only one side of the stud, an eccentricity exists during loading which can cause more movement in the shearwall system. 4. Unrestrained anchor bolt nuts can spin loose during cyclic loading; using steel nylon locking nuts or thread adhesive may prevent nut spin. 5. Movement can occur when nuts are not tightened enough. Retightening bolts before covering wall may prevent this. 6. Deflection can occur in the holdown under load caused by stresses due to earthquake or high wind. 7. Lateral displacement at the top of the wall rotates the stud around its base causing the holdown base plate to displace vertically. B. Wood shrinkage can occur due to drying of the sill plate, rim joist, and/or lop plate; nuts may require retightening. 9. Uplift forces on the bolts can cause localized wood crushing at bolt bearing locations. Using larger bearing plates may prevent this. 10. Wood at the end of the studs (sill plates, rim joists, etc.) may crush under normal dead and live loading; additional compressive forces due to overturning during earthquake and high wind loads add to the deflection. 9. Deflection at Highest Allowable Design Load; The deflection of a holdown measured between the anchor bolt and the strap portion of the holdown when loaded to the highest allowable load listed in the catalog table. This movement is strictly due to the holdown deformation under a static load test conducted on a steel jig. All other sources of deflection shall be in addition. 10. When using structural composite lumber columns, bolts must be applied to the wide face of the column. 11. The Designer shall reduce the allowable loads shown per NDS requirements when bolt threads are in the shear plane. 12. HDA and HD allowable loads are based on the lower of the 2001 NDS fastener values or the ultimate load on a steel test jig divided by 2.5, 13. Post design shall be by Designer. 11 Hwo,wm� may be r;;,set! nil :ili plat(. H,�t;;r to tahln fr; inr.rr�a&tad tleflertion vnlu'-"s ;rrai;n?i:: I1Ic1, RCtgr to note.1 n:;tic 14 fn? I?I tallarim in_Irn,,tlans nt rpc;rtl I;uluv.en:... 9 ji2l � BEARING LY.' 5 } fi 71 A PLATES �-- STUD SILL PLATE A FOUNDATION HOLDOWN ' q ANCHOR Q (2) and QB do not apply to the PHD and HDO. BP's are required by the City of Los Angeles. Check with your local building code on usage. (NDS Section 11.1.2.3 requires a metal plate, metal strap, or minimum of a standard cut washer.) a 0 y 39