2022 Maintenance LogPreventative Maintenance Level 3
Intersection
Work Order #
MILES AVE PEDESTRIAN CROSSING
52572
Date
09/06/2022
Check flash operation of police panel. Check flash operation of maintenance panel. Loosen and secure all field landings.
El❑✓ ❑✓
Upgrade flash transfer relays, load switch flashers, and load switches. Qty of Relays n Qty of Flasher 0 Qty of Load Switches
❑✓
Vacuum and dust Electrical service cabinet. Test voltage drop from service to cabinet breaker.
El El
Clean and re -seal cabinet base with industrial sealant.
El
Test cabinet power supply
El
12 Volts DC
11.90
Clean & Lubricate all cabinet locks
El
24 Volts DC
23.91
Inspect dust filter
Cabinet Voltage NC
120.9
Test cooling fan operation
El
Replace
Vacuum and inspect cabinet for damage, graffiti or function. Dust and clean shelves and components.
El
Inspect Controller event log. Note any repeating issues
El
Test Battery Back Up System
El
54.30
Battery Volts End
50.17
Test Run Time
1.5
Test Results
(Pass
Comprehensive check of vehicle detection for all phases. Adjust or repair detector files as necessary.
El
Inspect all approaching phases for roadway or sidewalk damage. Photograph each phase approach for digital log.
El
El
Check all approaches for sight distance issues with foliage. Correct as necessary.
El
Inspect all signal poles for damage, missing hand hole covers or graffiti.
El
Inspect and retro-reflective test all traffic control signs for all approaches. Replace based on test results.
El
Inspect all phase indications for operation and brightness.
Replace as necessary.
El
RB
0
0
GB
0
Check operation of all Pedestrian Push Buttons, signs and frameworks. Upgrade all buttons to Polara Bulldog type.
El
Buttons
3
Frameworks
0
Test Emergency Vehicle Preemption
❑✓
Sign
2
Northbound
None
Q
Southbound
None
Monitor traffic flow and operational smoothness. Notify Traffic Engineer of any issues.
❑✓
Field note or recommended repairs
Eastbound
Pass
RA
0
Westbound
(Pass
Q
0
Pedestal Voltage NC
120.9
Battery Date
09/01/2021
GA
0
PED
0
- 54 CONTROLLER EVENTS
- BBS: EVTS-6, RUN-1.5
- 1-PSM
9/12/22, 2:24 PM
Print Request
Request: 52572 Entered on: 07/21/2022 11:24 AM By: Kristopher Gunterson
Customer Information
Name: Kristopher Gunterson
Address:
Phone: (760) 636-8170
Alt. Phone:
Email: kgunterson@laquintaca.gov
Request Classification
Topic: Traffic Signals - 1082
Status: Work Done
Assigned to: Kristopher Gunterson
Problem Location: Miles Avenue Pedestrian Crossing
Request type: Maintenance
Priority: Normal
Entered Via: Internal
Original Date:
Time of Day:
Reoccurs Every:
Intersection: Miles Ped Crossing (John Glenn Middle School)
Perform LEVEL 3 Preventative Maintenance
Description
- PERFORMED LEVEL 3 MAINTENANCE
- VACUMMED/CLEANED OUT PULL BOXES
- WORK DONE
Date Expect Closed: 10/31/2022
Reason Closed
Enter Field Notes Below
Notes:
Notes Taken By: Date:
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6393809&type=0 1/2
9/12/22, 2:24 PM Print Request
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6393809&type=0 2/2
Preventative Maintenance Spot Check
Work Order #
a Roc,
Date Jo1100T,1----JIntersection +rr�.,..� _Criss:
Inspect Controller Event Log. Note any repeating issues.
oComplete
Monitor vehicle detection for all phases. Adjust or repair detector files as necessary
Inspect all approaching phases for roadway or sidewalk damage
Inspect all signal poles for damage, missing hand hole covers or graffiti.
Inspect all phases indications for operation and brightness Replace as necessary
Check operation of Pedestrian Push Buttons.
Inspect all traffic control signs for all approaches.
Monitor traffic flow and operational smoothness. Notify Traffic Engineer of any issues
Notes or recommended repairs.
It ( 0h4 ro r Vw 4S
3/3/22, 2:46 PM Print Request
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6142542&type=0 1/2
Request: 50866 Entered on: 02/28/2022 1:44 PM By: Kristopher Gunterson
Customer Information
Name:Kristopher Gunterson Phone:(760) 636-8170
Address:Alt. Phone:
,Email:kgunterson@laquintaca.gov
Request Classification
Topic:Traffic Signals - 1082 Request type:Maintenance
Status:Closed Priority:Normal
Assigned to:Kristopher Gunterson Entered Via:Internal
Problem Location:Miles Avenue Pedestrian Crossing
Original Date:
Time of Day:
Reoccurs Every:
Intersection:Miles Ped Crossing (John Glenn Middle School)
Description
Perform "SPOT CHECK" maintenance of the intersection.
Reason Closed
* 11 CONTROLLER EVENTS(CLEARED)
Date Expect Closed: 03/21/2022
Date Closed: 03/03/2022 2:47 PM By: Kristopher Gunterson
Enter Field Notes Below
Notes:
Notes Taken By: Date:
3/3/22, 2:46 PM Print Request
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6142542&type=0 2/2
Preventative Maintenance Level 2
Work Order #
50019
Date 01/03/2022 Intersection
Vacuum and inspect all cabinets for damage, graffiti or function.
❑✓
Inspect cooling fan operation.
❑✓
Inspect Controller Event Log. Note any repeating issues.
❑✓
MILES PEDESTRIAN CROSSING
Record BBS Log Number of Events Run Time
❑✓ 030
Test Power Supply 12 Volts DC 24 Volts DC
❑✓ 11.90 3.91
Test Battery Back Up System Beginning Voltage Ending Voltage Test Run Time Minutes
Pass 154.97 120MINS
Dust and clean cabinet shelves and components. Dust Filter
❑✓ lClean
Comprehensive Check of vehicle detection for all phases. Adjust or repair detector files as necessary.
❑✓
Inspect all approaching phases for roadway or sidewalk damage.
❑✓
Inspect all signal poles for damage, missing hand hole covers or graffiti.
❑✓
Inspect all phases indications for operation and brightness. Replace as necessary.
❑✓
Check operation of Pedestrian Push Buttons.
❑✓
Inspect all traffic control signs for all approaches.
❑✓
Monitor traffic flow and operational smoothness. Notify Traffic Engineer of any issues.
❑✓
Test Emergency Vehicle Preemption Northbound Southbound Eastbound Westbound
❑✓ Pass Pass Pass Pass
Clean and Lubricate all cabinet locks.
❑✓
Notes or recommended repairs.
rform inventory checklist for future LEVEL 3 ANNUAL MAINTENANCE.
Ball LED 0_
,w Ball LED_0_
�n Ball LED 0
Arrow LED 0
,w Arrow LED_0_
�n Arrow LED 0
i Transfer Relay_0_
og Pedestrian Push Button_2
) PLATES 1
i. ISNS MISSING
CONTROL EVENTS
GFCI NEEDS TO BE REPLACED
AIR FILTERS NEEDED
1/5/22, 11:57 AM Print Request
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6005791&type=0 1/1
Request: 50019 Entered on: 11/29/2021 1:34 PM By: Armando Cabrera Jr
Customer Information
Name:Armando Cabrera Jr Phone:(760) 912-5838
Address:Alt. Phone:
,Email:acabrera@laquintaca.gov
Request Classification
Topic:Traffic Signals - 1082 Request type:Problem
Status:Work Done Priority:Normal
Assigned to:Kristopher Gunterson Entered Via:Web
Problem Location:Miles Pedestrian Crossing
Original Date:
Time of Day:
Reoccurs Every:
Intersection:Miles Ped Crossing (John Glenn Middle School)
Description
* Perform LEVEL 2 Preventative Maintenance
Reason Closed
- PERFORMED LEVEL 2 MAINTENANCE
- WORK DONE
Date Expect Closed: 01/31/2022
Enter Field Notes Below
Notes:
Notes Taken By: Date: