05-3264 (CSCS) Title 24I TITLE 24 REPORT Title 24 Report for: The Dunes Retail Center (Building Parde- 4-(Highway 11111- )-La Quinta, CA Project Designer: KKE Architects, Inc 525 East Colorado Boulevard Pasadena, CA 91101 626-796-8230 Report Prepared By: SIA GARESTANI, P.E. SPEC Engineering 6800 Owensmouth Ave. #140 Woodland Hills, CA 91303 (818) 592-6643 (— Job Number: 05-250 Date: 10/3/2005 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FO�S?NZopo N DA BY L96�L The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: 05-250 User Number: 3358 j 1 . TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV-MM Envelope Mandatory Measures 12 Form MECH-MM Mechanical Mandatory Measures 13 HVAC System Heating and Cooling Loads Summary 15 f EnergyPro 3.1 By EnergySoft Job Number: 05-250 User Number: 3358 EnergyPro 3.1 By EnergySoft Job Number: 05-250 User Number: 3358 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-1 )JECT NAME The Dunes Retail Center Building "C' )JECT ADDRESS Parcel 4 (Highway 111) La Quinta NCIPAL DESIGNER - ENVELOPE KKE Architects, Inc 'UMENTATION AUTHOR SPEC Engineering TELEPHONE 626-796-8230 TELEPHONE (818) 592-6643 DATE 10/3/2005 Building Permit# Checked. by/Date '..Enforcement Agency Use : GENERAL INFORMATION DATE OF PLANS 07-14-05 BUILDING CONDITIONED FLOOR AREA 8, 754 sq.Ft. CLIMATE ZONE 15 BUILDING TYPE NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the perfor nce compliance approach. DOCUMENTATION AUTHOR SIGNATURE DATE SIA GARESTANI, P.E. l p-o3�5 The Principal Designers hereby certify that the proposed buildi g ign repr ented in the construction documents and modelled for this permit application are consistent with all other forms a orksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meet he energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. ❑ ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures NV-1 Required FQ PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATU LIC. NO. DATE KKE Architects Inc LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms TITis Submittal PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ME -1, MECH-2, MECH-3 Required Form PRINCIPAL MECHANICAL DESIGNER - NAME SIA GARESTANI P.E. SIGNATUR / LIC. NO. rt7�p�-} DATE ��-p3--�5� mun initiation lime: 1U/U3705 10:53:35 Run Code: 1128362315 EnergyPro 3.1 By Energysoft User Number: 3358 Job Number: 05-250 Paoe:3 of 19 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-' DATE The Dunes Retail Center (Building "C") 10/3/2005 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r Standard ENERGY COMPONENT Design Space Heating 1.71 Space Cooling 73.51 Indoor Fans 16.83 Heat Rejection Pumps & Misc. p 0.00 Domestic Hot Water 0.00 r Lighting 50.07 Receptacle 15.93 Process���'� 33.89 Percent better than Standard: Proposed Design 0.82 69.80 18.26 0.00a 0.00 50.07 15.93 33.89 188.78 1.6% Compliance Margin ;Standard:.. - . Prgpd ma o3a r '� t t u�x+he F 0.89I 6i . 3.70 ,..., .s 1.44'""�"Fm" • µ f , .. , .. o- r A " Ry aF� 0.00 0.00 0.00 0.00 " 0.00 "r :.0 o io i 3o NMIa kBTOTALS: tWSg(1y ° "., . M. F• ..T` w «-. t191.94 ( 2.0% excluding process) BUILDING COMPLIES ' GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones South)180 deg Conditioned Floor Area 8,754 sqft. Unconditioned Floor Area 0 sqft. Conditioned Footprint Area 0 sqft. 1 5 5 - Orientation Front Elevation (South) Left Elevation (West) Rear Elevation (North) Right Elevation (East) Total Roof Gross Area sqft. sqft. sqft. sqft. sqft. sgft.sgft. Glazing Area Glazing sqft. sqft. sqft. sgft. sgft. Ratio 2,254 971 43.1% 0 0 0.0% 2,254 0 0.0% 0 01 0.0% a,5o8 971 21.5% 8,754 0.0% Standard Proposed Lighting Power Density 1.700 W/sgft. 1.700 W/sqft. Prescriptive Env. Heat Loss 1.272 Btu/h 1,691 Btu/h Prescriptive Env. Heat Gain 164,087 Btu/h-F 207,618 Btu/h-F LEEDTM E_ne[gy_$� AtrnosphQre Credit. Savings vs. Title 24 2.22% Energy Performance Credit2 0 Points 1. excludes process and receptacle 2. see TEED table 8-t or 8-d Remarks: Run Initiation Time: 10/03/05 10:58:35 Run Code: 1128362315 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Page:4 of 19 r PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 ` PERT-1 PROJECT NAME The Dunes Retail Center(Building T" DATE 10/3/2005 __] ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)1 Port. LPD (W/sf)1 Ctrlr`: Credits W/s 2 Tailored Proc.,'. Loads' (W/sf) IPQ (W/sfj3 RTU-8 Building "C" Comp Bldg Retail/Wholesale 1,891 *1.700 2.000. RTU-9 Building "C" ' Comp Bldg Retail/Wholesale 2,389 *1.700 2:000 RTU-10 Building "C" Comp Bldg Retail/Wholesale 1,533 *1.700 `' 2:000: RTU-11 Building "C" Comp Bldg RetaiINVholesale 1,489 *1.700 2.000 RTU-12 Building "C" Comp Bldg Retail/Wholesale 1,453 *1.700 2.000 • �v _ 5 Y• Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 Items above require special :documentation .: EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST • •• •• "a"•••'1-••-w•4 Nar opav 01 4LLCIILIUII LV Lrle Items speciriea inims cnec Kest. i nese items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special iustification and documPntatinn cuhmittori The Zone "Building "C"" has a Display Perimeter Credit of 17 ft. rian mein The Zone "Building "C"" has a Display Perimeter Credit of 24 ft. The Zone "Building "C"" has a Display Perimeter Credit of 17 ft. The Zone "Building "C"" has a Display Perimeter Credit of 17 ft. The Zone "Building "C"" has a Display Perimeter Credit of 17 ft. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp Run Initiation Time: 10/03/05 10:58:35 Run Code: 1128362315 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 . Page:5 of 19 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE The Dunes Retail Center(Building "C" 10/3/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt Y/N Form 3 Reference Location / Comments 1 Wall Wood 492 0.065 0 90 X R-19 Wall W.19.2x6.16 Building "C" 2 Wall Wood 313 0.065 180 90 X R-19 Wall W.19.2x6.16 Building "C" 3 lRoof lWood 1.891 0.035 1 0 0 X R-30 Roof R.30.2x12.16 Building "C" 4 lWall Wood 612 0.065 0 90 X R-19 Wall W.19.2x6.16 Building "C" 5 lWall Wood 357 0.065 180 90 R-19 Wall W.19.2x6.16 Building "C" 6 lRoof Wood 2,389 0.035 0 0 X R-30 Roof R.30.2x12.16 Building "C" 7 Wall Wood 393 0.065 0 90 X11 IR-19Wall W.19.2x6.16 Building "C" 8 Wall Wood 214 0.065 180 90 X11 JR-19Wall W.19.2x6.16 Building "C" 9 Roof Wood 1,533 1 0.035 0 0 X11 I R-30 Roof R.30.202.16 Building "C" 10 Wall Wood 383 0.065 0 90 X I IR-19Wall W.19.2x6.16) Building "C" 11 Wall Wood 204 0.065 180 90 R-19 Wall .19.2x6.16 Building "C" 12 Roof Wood 1,489 0.035 0 0 X I I R-30 Roof R.30.2x12.16) Building "C" 13 Wall Wood 374 0.065 0 90 X I JR-19Wall W.19.2x6.16 Building "C" 14 Wall Wood 195 0.065 180 90 X I JR-19Wall W.19.24.16 Building "C" 15 Roof Wood 1,453 0.035 0 0 1 R-30 Roof R.30.2x12.16 Building "C' FENESTRATION SURFACES Site Assembled Glazing ACC^ uux �1 ouiwrny is iuu,uuu sqn or L FA and - 1U,000 sqtt vertical glazing then NFRC Certification is required. Fnllnw NFRC 1M_CR Prnrcrliiroc ­4 ­k. ;# KICDr i k i r, ..;;; . r # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments 1 Window 179 1.190 180 0.82 Single Clear Default NM Building "C" 2 Window 255 1.190 180 0.82 Single Clear Default NM Building "C" 3 Window 179 1.190 180 0.82 Single Clear Default NM Building "C" 4 Window 179 1.190 180 0.82 Single Clear Default NM "C' 5 Window 179 1.190 180 0.82 Single Clear Default NM -Building Building "C" EXTERIOR SHADING ## 1 Exterior Shade Type None SHGC 0.76 Window Hgt. Wd. 10.5 17.0 Overhang Left Fin Right Fin Len. Hat. LExt.RExt. 4.0 0.1 4.0 4.0 Dist. Len. H t. Dist. Len. H t. 2 None 0.76 3 None 0.76 10.5 17.0 4.0 0.1 4.0 4.0 4 None 0.76 1 10.5 17.0 4.0 0.1 4.0 4.0 5 None 0.76 10.5 17.0 4.0 0.1 4.0 4.0 Run Initiabon Time:0/ 5 •5 •35 Rum Coe 36 3 5 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Page:6 of 19 CERTIFICATE OF COMPLIANCE _ Performance MECH-1 PROJECT NAME DATE The Dunes Retail Center(Building "C" 10/3/2005 SYSTEM FEATURES SYSTEM NAME Programmable Switch Heating & Cooling Required n/a Yes' 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 645 cfm Heat Pump 3.40 COP Packaged DX 10.5 EER CARRIER 50HJ0007 Yes No Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto Fixed Temp Non-Inte 814 cfm ' Heat Pump 3.30 COP Packaged DX 10.3 EER CARRIER 50HJQ008 Yes No Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Require n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 522 cfm Heat Pump, 7.70 HSPF Packaged DX 13.0 SEER / 10.3 EER CARRIER 50HJ0006 Yes No Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above NOTE TO FIELD 0 t: \hY l ' HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch 0: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD 0: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144e3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 10/03/05 10:58:35 Run Code: 1128362315 EnergyPro 3.1 By Energysoft User Number: 3358 Job Number: 05-250 Page:? of 19 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE The Dunes Retail Center(Building "C" 10/3/2005 SYSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME RTU-11 RTU-12 NOTE .TO TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET 60OLING SUPPLY RESET _ HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 508 cfm Heat Pump 7.70 HSPF Packaged DX 13.0 SEER / 10.3 EER CARRIER 50HJQ006 Yes' No Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a , Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 495 cfm Heat Pump 7.70 HSPF Packaged DX 13.0 SEER / 10.3 EER CARRIER 50HJQ006 Yes No Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy Sensor C: Cooling B: Both Isolation Zones. P: Variable Pitch V: VFD VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? Y: Yes M: Manual Timer 0: Other C: Curve N: No HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? T.Air Balance A: Auto A: Air Enter Outdoor Air PIPE INSULATION REQUIRED? C: Outside Air Cert. M: Out. Air Measure D: Demand Control G: Gravity W: Water N: Not Required EC: Economizer CFM. Note: This shall be no less than Col. H on PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE N: Natural Control See Section 144e3 MECH-3. NOTE'S TO FIELD - For iRepartment Use Only Run Initiation Time: 10/03/05 10:58:35 Run Code:/128362315 .' EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Page:8 of 19 F MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME The Dunes Retail Center (Building "C") iDATE 10/3/2005 CHILLER AND TOWER SUMMARY Efficiency Tons PUMPS Equipment Name Equipment Type Qty. Tot. Qty JGPM BHP Motor Eff. Drive Eff. Pump Control 1DHW / BOILER SUMMARY TANK INSUL. Energy Factor or Recovery Efficiency Standby Loss or Pilot System Name System Type Distribution Type Qty Rated Input (Gals.) Vol. Ext. R-Val. E= CENTRAL SYSTEM RATINGS HEATING COOLING System Name CARRIER 50HJQ007 System Type Packaged DX Q 1 Output 69.000 Aux. kW 0.0 Eff. 3.40 COP Output 76,000 Sensible 56,40010.5 Efficiency EER Economizer Type No Economizer CARRIER 50HJQ008 Packaged DX 1 85,000 0.0 3.30 COPI 91,300 67,50010.3 EER Fixed Temp (Non-Integ) CARRIER 50HJQ006 Packaged DX 3 55,000 0.0 7.70 HSPF 63,800 45,80013.0 SEER / 10.3 EER No Economizer EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Pac of 19 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME The Dunes Retail Center Buildin "C„ TDATE10/3/2005 ZONE TERMINAL SUMMARY VAV TERMINAL BOX TERMINAL FAN BASEBOARD Zone Name System Type Qtv. Min. CFM Ratio Reheat Coil CFM BHP Motor Eff. Drive Eff. Type Output Type DeltaT EXHAUST FAN SUMMARY Room Name City. CFM BHP Motor Eff. Drive Eff. Room Name Q . CFM BHP Motor Eff. Drive Eff. Run Initiation Time: 10/03/05 10:58:35 Run Code: 1128362315 EnergyPro 3.1 By Energysoft User Number: 3358 Job Number: 05-250 Page:10 of 19 MECHANICAL VENTILATION MECH-3 PROJECT NAME The Dunes Retail Center (Building "C") DATE 10/3/2005 MECHANICAL VENTILATION o a© o 0 0© o o a o AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO TRANS. FER AIR ZONE/SYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Building "C" 1,891 0.23 435 43.0 15.0 645 645 645 RTU-8 Total 645 645 Building "C" 2,389 0.23 549 54.3 15.0 814 814 814 RTU-9 Total 814 814 Building "C" 1,533 0.23 352 34.8 15.0 522 522 522 RTU-10 Totall 522 522 Building "C" 1,489 0.23 342 33.8 15.0 508 508 508 RTU-11 Total 508 508 Building "C" 1,453 0.23 334 33.0 15.0 495 495 495 RTU-12 Totall 495 495 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Page:11 of 19 ENVELOPE MANDATORY MEASURES ENV-MM PROJECT NAME DATE The Dunes Retail Center (Building "C") I 10/3/2005 DESCRIPTION Designer Enforcement ❑X § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. FXJ § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating . and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. R§ 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). X❑ § 116(a)1 Manufactured Doors and Windows Installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U-value according to NFRC procedures. X § 118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have Insulation with an Installed R-value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySoft User Number: 3358 • Job Number: 05-250 Page:12 of 19 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE The Dunes Retail Center (Building "C") 10/3/2005 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies § 111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. �✓�� I X] § 115(a) Fan type central furnaces shall not have a pilot light. X § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with V Standards Section 123. a§ 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: �— X § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)1 B An occupancy sensor to control the operating period of the system; or 0 § 122(e)1 C A 4-hour timer that can be manually operated to control the operating period of the system. / R§ 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback / ✓ heating and/or a setup cooling thermostat setpoint N /� § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat w ' that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. a§ 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. ❑ § 112(b) Heat pumps shall be installed with controls to prevent electric resistance I supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User'Number: 3358 Job Number: 05-250 Page:13 W 19 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE The Dunes Retail Center (Building "C") 10/3/2005 Description Designer Enforcement Ventilation LXI § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at / the ventilation rates as specified on these plans. U § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air Intakes and discharges of all space conditioning and exhaust systems. X❑ § 142(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. ❑ § 121(f)1 Air Balancing: The system shall be balanced In accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or § 121(02 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or ❑ § 121(f)4 Another method approved by the Commission. , Service Water Heating Systems § 113(b)2 If a circulating hot water system is Installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. X § 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Page:14 of 19 1HVAC SYSTEM HEATING AND .COOL ING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center (Building "C") 10/3/2005 SYSTEM NAME FLOOR AREA RTU-8 1,891 NG Number of Systems 1 Heating System Output per System 69,000 Total Output (Btuh) 69,000 Output (Btuh/sgft) 36.5 Cooling System Output per System 76,000 Total Output (Btuh) 76,000 Total Output (Tons) 6.3 Total Output (Btuh/sgft) 40.2 Total Output (sgft/Ton) 298.5 Air System CFM per System 2,400 Airflow (cfm) 2,400 Airflow (cfm/sgft) 1.27 Airflow (cfm/Ton) 378.9 Outside Air (%) 26.9 Outside Air (cfm/sgft) 0.34 Vote: values above EATING SYSTE 24.0 OF Outside Air 645 cfm COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible Total Room Loads 2,486 Return Vented Lighting Return Air Ducts Return Fan Ventilation say Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 1 51,001 8,165 0 2,550 0 25,677 13,760 0 217924 2,550 82 38 48,572 CARRIER 50HJQ007 66,684 2,710 43,493 Total Adjusted System Output 66,68a 2,710 a3,a93 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm L Jan 12 am -earn Temperatures at Time of Heating Peak) 105.0 of 105.0 OF Supply Air Ducts Heating Coil Supply Fan 104.7 °F 2400 cfm ROOMS 69.7 of 70.0 OF Return Air Ducts 12.0 / 78.5 of O—�ut--7i side Air 645 cfm 75.1 / 62.1 OF at ARI conditions 57.4 of ►irstream Tern 85.0/66.7OF . �ratures at Time of Cooling Peak) 55.0 / 53.4 of 55.0 / 53.4 of Supply Air Ducts Cooling Coil Supply Fan 56.1 / 53.9 OF 2400 cfm 49.9% R.H. ROOMS 74.0 / 61.7 OF h Return Air Ducts 4 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 15 of 19 IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center Building "C") 10/3/2005 SYSTEM NAME FLOOR AREA RTU-9 2,389 NE Number of Systems 1 Heating System Output per System 85,000 Total Output (Btuh) 85.000 Output (Btuh/sqft) 35.6 Cooling System Output per System 91,300 Total Output (Btuh) 91,300 Total Output (Tons) 7.g Total Output (Btuh/sgft) 38.2 Total Output (sgft/Ton) 314.0 Air System CFM per System 3,000 Airflow (cfm) 3,000 Airflow (cfm/sgft) 1.26 Airflow (cfm/Ton) 394.3 Outside Air Outside Air (cfm/sgft) 0.34 Note: values above qiven at ARI conditions 24.0 OF } 0 Outside Air 814 cfm 69.7 of 106.1 / 74.1 of �110—� Outside Air 814 cfm 75.3 / 62.1 °F 57.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 3,989 81,826 10,316 1 4,0911 1 8141 27,0881 7,3201 0 4,091 117,2751 17,6361 HVAC EQUIPMENT SELECTION CARRIER 50HJQ008 81,717 2,240 53,578 Total Adjusted System Output 81 717 2,240 53,578 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Sep 2 pm Jan 12 am 'earn Temperatures at Time of Heating Peak) 105.0 of 105.0 of Supply Air Ducts 0 Heating Coil Supply Fan 104.7 F 3000 cfm ROOMS 70.0 OF �i Return Air Ducts 4 ►irstream Temperatures at Tim 83.7 / 65.3 of 0 55.0 / 53.4 of Cooling Coil Supply Fan 3000 cfm 55.0 / 53.4 of —�j Supply Air Ducts 56.3 / 53.9 OF 49.8% R.H. I ROOMS 74.0 / 61.7 OF h Return Air Ducts 4 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 10oria IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center Building "C") 10/3/2005 SYSTEM NAME FLOOR AREA RTU-10 1,533 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 55,000 Total Output (Btuh) 55,000 Output (Btuh/sgft) 35.9 Cooling System Output per System 63,800 Total Output (Btuh) 63,800 Total Output (Tons) 5.3 Total Output (Btuh/sgft) 41.6 Total Output (sgft/Ton) 288.2 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.31 Airflow (cfm/Ton) 376.2 Outside Air (%) 26.1 Outside Air (cfm/sgft) 0.34 Note: values above (EATING SYSTE 24.0 OF Outside Air 522 cfm 69.7 OF 07.0 / 74.3 OF Outside Air 522 cfm 75.2 / 62.0 OF at ARI conditions YCHROMETRICS 57.7 OF PS Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensible Latent CFM Sensible 2,273 46,615 6,618 372 14,074 0 2,331 704 0 0 522 17,958 4,708 522 25,761 0 0 2,331 704 69,5831 11,3251 41,242 CARRIER 50HJQ006 55,118 3,176 Total Adjusted System Output (Adjusted for Peak Design Conditions) I 55,118I 3,176 34,668 34,668 TIME OF SYSTEM PEAK Sep 3 pm Jan 12 am moeratures at Time of Heatina Peakl 105.0 OF Heating Coil S Supply Fan 2000 cfm 105.0 OF —310Supply Air Ducts 104.7 OF ROOMS 70.0 OF Return Air Ducts 4 83.5 / 65.2 OF 0 55.0 / 53.4 OF Cooling Coil Supply Fan 2000 cfm d Cooling Peak) 55.0 / 53.4 OF 4, Supply Air Ducts 56.2/53.8OF 49.6% R.H. I ROOMS 74.0 / 61.6 OF h Return Air Ducts EnergyPro 3.1 8y EnergySoft User Number: 3358 Job Number: 05-250 Page:17 of 19 IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center Building "C") 10/3/2005 SYSTEM NAME RTU-11 FLOOR AREA 1 489 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 55,000 Total Output (Btuh) 55,000 Output (Btuh/sqft) 36.9 Cooling System Output per System 63,800 Total Output (Btuh) 63,800 Total Output (Tons) 5.3 Total Output (Btuh/sqft) 42.8 Total Output (sgft/Ton) 280.1 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.34 Airflow (cfmrron) 376.2 Outside Air (%) 25.4 Outside Air (cfm/sgft) 0.34 Note: values above JEATING SYSTE 24.0 of Outside Air 508 cfm 69.7 of at ARI conditions YCHROMETRICS 58.1 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK_ ICOILHTG.PEAK CFM I Sensible Latent CFM I Sensible E68,097 11,038 40 370 CARRIER 50HJQ006 54,863 3,326 34,668 Total Adjusted System Output 54,863 3,326 34,668 (Adjusted for Peak Design Conditions) 105.0 of Heating Coil TIME OF SYSTEM PEAK I Sep 3 pm I Jan 12 am at Pea 105.0 of Supply Air Ducts Supply Fan 104.7 of 2000 cfm ROOMS 70.0 of h Return Air Ducts 4 m Temaeratures 07.0 / 74.3 of 83.2 / 65.0 of 0 55.0 / 53.4 of 55.0 / 53.4 of Outside Air 508 cfm Cooling Coil 75.1 / 62.0 of Supply Air Ducts Supply Fan 56.1 / 53.8 of 2000 cfm 49.6% R.H. ROOMS 74.0 / 61.6 of Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number 05-250 Page:18 of 19 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center (Building "C") 10/3/2005 SYSTEM NAME FLOOR AREA RTU-12 1 AR'A Number of Systems 1 Heating System Output per System 55,000 Total Output (Btuh) 55,000 Output (Btuh/sgft) 37.8 Cooling System Output per System 63,800 Total Output (Btuh) 63,800 Total Output (Tons) 5.3 Total Output (Btuh/sgft) 43.9 Total Output (sgft/Ton) 273.3 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.38 Airflow (cfm/Ton) 376.2'I Outside Air (%) 24.8 Outside Air (cfm/sgft) 0.34 ote: values above given at ARI conditions :ATING SYSTEM PSYCHROMETRICS 24.0 OF 58.4 OF Outside Air 495 cfm 69.7 OF SYS' Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 66,872 1 Q80 CARRIER 50HJQ006 54,655 3,448 Total Adjusted System Output (Adjusted for Peak Design Conditions) 5a,655 3,448 34,668 34,668 TIME OF SYSTEM PEAK Sep 3m F Jan 12 am weratures at Time of Heatina Peak1 105.0 OF Heating Coil 105.0 OF Supply Air Ducts Qv: e' Supply Fan 104.7 OF 2000 cfm ROOMS 70.0 OF Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 107.0 / 74.3 OF 83.0 / 65.0 OF 55.0 / 53.4 OF 55.0 / 53.4 OF Supply Air Ducts Outside Air 495 cfm Cooling Coil Supply Fan 56.1 / 53.8 OF 2000 cfm 49.5% R.H. ROOMS 75.1 / 62.0 °F 74.0 / 61.6 OF dc I EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-250 Page:19 of 19