06-2973 (CSCS) Revision 1 Title 24
---�` . TITLE 24 REPORT Title 24 Report for: 78 983 Highway 111 ��? PLus - E 92253 Project Designer: KKE Architects, Inc. 525 E. Colorado Blvd., 4th Floor Pasadena, CA 91101 (626) 796 8230 Report Prepared By: Sang Lee S.Y. Lee Associates 143 S. Glendale Ave., Suite #205 GLENDALE, CA 91208 (818) 244-4337 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED - FOR CONSTRUCTION DATF ZZ 07 gY l�JSCd L C& -217 3 Job Number: 5352 Date: 1/30/2007 jRpFESS/pN SOL ROFGgt F� do CMIr OF CZI�V p)l�9 LtuuL�ID �l FEB 012007 W The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by EnergySoft Job Number. 5352 User Number. 3193 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -MM Envelope Mandatory Measures , Form MECH-MM Mechanical Mandatory Measures 1 2 3 11 12 EnergyPro 4.2 by EnergySoft Job Number. 5352 User Number: 3193 A PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is ac rate nd complete. DOCUMENTATION AUTHOR DATE OF PLANS 7-18-06 BUILDING CONDITIONED FLOOR AREA 17,197 Sq.Ft. o CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION E] ADDITION FI F-1 ❑ 2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is ac rate nd complete. DOCUMENTATION AUTHOR SIGNATU DAIE Sang Lee o The Principal Designer hereby certifys that the proposed build'pOesir presented in this set of construction docum nts is consistent with the other compliance forms and worksheets, with the s ecifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the ener y efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. El ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or 1 am a licensed architect. FI F-1 ❑ 2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. 3. 1 affirm that 1 am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE - KKE Architects Inc. LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MEC -1 MECH-2 MECH-3 MECH-5 Required For PRINCIPAL MECHANICAL DESIGNER -NAME SIGNATOR IC. NO. AYE S. Y. Lee Associates Inc. Q Z r3o6 EnergyPro 4.2 by EnergySoft User Number. 3193 Job Number. 5352 Page:3 of 13 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF - PROJECT NAMEDATE Washington Park Subma•or.2 1/30/2007 ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed ENERGY COMPONENT Design Design Space Heating1.75 0.19 Space Cooling 373.33 265.80 Indoor Fans �. 106.52 106.88 Heat Rejection 0.00 0.00 Pumps & Misc. 0.00 0.00 Domestic Hot Water o:oo 0.00 Lighting 155.99155.99 Receptacle 83.19 $3.19 Process 0.00 TOTALS: 720.79 612.05 Percent better than Standard: 15.1% Compliance Margin iC "Stenaedax ISP 1.57 ty -yams s � 4011 ^ , Yui g , 4 ' 7 �w� a z' r, � "° � y vRX 3 i:a+y ° 0-i A -1290 180`2t0.240 270%3000x 860 in 107.53 -0.36 0.00'°` 0.00 0.00 0.00 0.00 108.74 ( 15.1% excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation w 270 deg Conditioned Floor Area 17,197 sgft Number of Stories 1 Unconditioned Floor Area 0 sgft. Number of Systems 5 Conditioned Footprint Area 0 sgfL Number of Zones 2 Fuel Type Natural Gas Orientation Gross Area Glazing Area Glazing Ratio Front Elevation W 3,848 sgfL 395 sgft 10.3% Left Elevation (N) 4,572 sgft. 0 sgft. 0.0% Rear Elevation E 3,567 sgfL 0 sgft. 0.0% Right Elevation (S 2,499 sgft. 0 sgft. 0.00 Total 14,486 sgft. 395 sgft. 2.7% Roof 15,617 sgft. sgft. 0.0% Standard Proposed Lighting Power'Density 1.468 W/sgft. 1.338 W/sgft. Prescriptive Env. Heat Loss 2,435 Btu/h 2,040 Stu/h Prescriptive Env. Heat Gain 198,712 Btu/h-F 216,103 Btu/h-F Remarks: Run Initiation Time: 09/21/06 16:52:17 Run Code: 1158882737 Energypro 4.2 by EnergySoft User Number. 3193 Job Number. 5352 Page•4 of 13 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAMEDATE Washin ton Park Subma'or 2 —7-1/30/2007 ZONE INFORMATION System Name Zone Name Occu anc T e P Y YP Floor Area (sgft•) Inst. LPD ( f)1 Ctrl. Credits (W/sf)2 Allowed LPD Proc. Loads (W/sf) Area 3 Tailored (W/s I AC -2 Office and Auxiliary Office 1,862 0.00 AC -1 Sales Area Comp Bldg Retail and Wholesale 15,335 -1.5001 Notes: 1. See LTG -2-C 2. See LTG4-C 3. See LTG -5-C (items marked with asterisk, see LTG -2 -C by others) (by others) 4. See LTG -6-C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST i ne iv(pai emorcehient agency snows pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Lennox LGA180H2B" includes an Economizer. This system has a cooling output < 75,000 Btuh or a supply cfm < 2500. The HVAC System "Lennox LGA180H2B" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Lennox LGA072HB" includes an Economizer. This system has a cooling output < 75,000 Btuh or a supply cfm < 2500. Tr._ ..a exceptional matures nstea in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or EnergyPro 4.2 by EnergySoft User Number: 3193 Job Number 5352 Page:5 of 13 CERTIFICATE OF COMPLIANCE ENV -1-C (PROJECT NAME DATE Washington Park Submajor 2 1/30/2007 OPAQUE SURFACES # Surface Type I Area U -Fac. Insulation Cay. Cont. Act. Azm. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Wall 288 0.074 R-19 R-0.0 270 90 New 09-A5 Office and Auxiliary 2 Wall 292 0.074 R-19 R-0.0 90 90 New 09-A5 Office and Auxiliary 3 Wall 1,776 0.074 R-19 R-0.0 180 90 New 09-A5 Office and Auxilia 4 Roof 99 0.051 R-19 R-0.0 0 0 New 02-A5 Office and Auxiliary 5 Wall 260 0.074 R-19 R-0.0 0 90 New 09-A5 Office and Auxiliary 6 lRoof 39 0.051 R-19 R-0.0 0 0 New 02-A5 Office and Auxiliary 7 lWall 225 0.074 R-19 R-0.0 180 90 New 09-A5 Office and Auxiliary 8 Roof 230 0.051 R-19 R-0.0 0 0 New 02-A5 Office and Auxiliary 9 Wall 318 0.074 R-19 R-0.0 180 90 New. 09-A5 Office and Auxiliary 10 Roof 214 0.051 R-19 R-0.01 0 0 1 New 02-A5 Office and Auxiliary 11 Wall 180 0.074 R-19 R-0.0 180 90 New 09-A5 Sales Area 12 Wall 4,3121 0.074 R-19 R-0.0 0 90 New 09-A5 Sales Area 13 lRoof 15,335 0.051 R-19 R-0.0 0 0 New 02-A5 Sales Area 14 lWall 3,165 0.074 R-19 R-0.0 270 90 New 09-A5 Sales Area 15 lWall 3,275 0.074 R-19 R-0.0 90 90 New 09-A5 Sales Area K E. A. R (New, Existing,'ucereo, Removed/ FENESTRATION SURFACES More than or equal to 10,000 sq.flt of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default label Certificate using the default U -factors from Standards Table 116-A and B Certificate shall be filed in the contractor's oroiect office during ednswelien and 'n the h 'id' r is n n uu� ype:'d-n ueramc i awa nom atanoims, I awe NI -1 uetault I adle from the AGM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang Left Fin Right Fin ## Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES 11The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.fL If this box is checked. ENV -4-C must he fillwl m,t whore sohmtnl.... ,,.,de. •hn o.e«.:..u.,e r•......,r---- -------I I EnergyPro 4.2 by EnergySoft User Number. 3193 Job Number. 5352 Page:6 of 13 a CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME DATE Washington Park Submaior 2 1/30/2007 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of_Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the renuirementc of Sertinn 1 n_1 nsfht and r+tp 9a Pnrt A STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This lest required If the unit serves 5,000 V of space or less and 25% or more of the ducts are in nonoonditioned or semioonditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. - -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btufhr. -Water-loop Heat Pump Controls Applies to all new waterloop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heal pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.2 by EnergySoft User Number: 3193 Job Number: 5352 Page:7 of 13 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE Washington Park Submajor 2 1/30/2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone AC -2 AC -1 1 4 Reference on Plans or Specification 1 112(a) 83% AFUE 82% AFUE 112(a) 10.5 EER 11.8 EER 112(b) n/a n/a 112(c), 115(a) n/a n/a 121(b) Yes Yes 121(b) 453 cfm 10223 cfm 121 c No No 121(c) No Yes 121(c), 122(e) Programmable Switch Programmable Switch 122(e) Heating & Cooling Required, Heating & Cooling Required 122 Auto Auto 122(g) n/a n/a 123 124 R-8.0 R-8.0 144 a & b n/a n/a 144 a & b 98,800 btuh 832,000 btuh 144 a & b n/a n/a 144 a & b 62,310 btuh 548,277 btuh 144 c Constant Volume Constant Volume 144 c 144 c Yes Yes 144 d No No 144 a Fixed Tem (Integrated) Fixed Tem (Integrated) 144 Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp 144 k) No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.2 by EnergySoft User Number: 3193 Job Number: 5352 Page:8 of 13 MECHANICAL VENTILATION MECH-3-C PROJECT NAME n Park Sub DATE 1/30/2007 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d)) MECHANICAL VENTILATION Section 121(b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N ZONE/SYSTEM 0 D� TSO. 0 J, d n ®m71 c 3 �'�S.3 XDn °' 3 Z �� OtS m o A n ym'n ' 1 � m 03 X no -n aCj �" 0 3 _ 03m 0X D '<° o -n r. Ln. 3 D' O� ' N o Ttn— 3� o n TW 3X -,� j' 0 C �� p7K T x� 3 c- to '0 ? D �. D Office and Auxiliary 1,86 0.15 279 279 453 AC -2 Total 279 453 Sales Area 15,335 0.22 3,374 511.2 20.0 10,223 10,223 10,223 AC -1 Total 10,223 10,223 C Minim— ventilation rate per Section 121. Table E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air REO'D VA is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supply dm Fan CFM x 30%: or K Condition area ft. sq.) x 04 dm/ft. sq.: or L Maximum of Columns H, J. K, or 300 cfm M This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M. EnergyPro 4.2 by Energ Soft User Number. 3193 Job Number. 5352 Page: 9 of 13 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Washington Park Subma'or 2 DATE 1/30/2007 CHILLER AND TOWER SUMMARY System Type Distribution Type Qty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. Efficiency TonsGPM PUMPS Equipment Name Equipment Type Qty. �Taoo5t BHP Motor Eff. Drive Eff. Pump Control DHW / BOILER SUMMARY MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Condition System Name System Type Pty Output kW Eff. Outout Efficienicy Status Economizer Type Lennox LGA072H6 Packaged DX 1 98,800 5.0 83%AFUE 73,000 10.5 EER New Fixed Temp (Integrate( ) Lennox LGA180H26 Packaged DX 4 208,000 5. 82% AFUE 177,50011.8 EER New. Fixed Temp (Integrate ) Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. -T MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Condition System Name System Type Pty Output kW Eff. Outout Efficienicy Status Economizer Type Lennox LGA072H6 Packaged DX 1 98,800 5.0 83%AFUE 73,000 10.5 EER New Fixed Temp (Integrate( ) Lennox LGA180H26 Packaged DX 4 208,000 5. 82% AFUE 177,50011.8 EER New. Fixed Temp (Integrate ) ENVELOPE MANDATORY MEASURES ENV - PROJECT NAME DATE Washington Park Subma'or 2 1/30/2007 DESCRIPTION Designer Enforcement ❑ § 118(,) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. ❑ § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. ❑ § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. ❑ § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). ❑ § 116(,)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. -§118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. EnergyPro By EnergySoft User Number. User Job Number. 5352 Page: 11 of 13 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM (PROJECT NAME DATE Washington Park Submajor 2 11/30/2007 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. ❑ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that 1 prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)l B An occupancy sensor to control the operating period of the system; or ❑ § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(8) Each space conditioning system serving multiple zones with a combined - conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. NA § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number. User Job Number: 5352 Page: 12 of 13 [MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE Washington Park Subma'or 2 1/30/2007 Description Designer Enforcement' Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ❑ § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. ❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or �Q § 121(02 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or ❑. § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(f)4 Another method approved by the Commission. Service Water Heating Systems F] § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. �( § 113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By EnergySoft User Number. User Job Number. 5352 Page:13 of 13 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C PROJECT NAME DATE COST PLUS MARKET PLACE 11/14/2006 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES Luminaire Lam s/Ballasts Installed Watts D I E F G H I J Name Type Description � m 03 CD -0 3 3 3 � Cr ..0 CD m m o yv � 3mm V1y 3 0 3 9�v �•� m m o 3v 3�d_ 'N m �C� C vm C r 3 c X03 w C N xmd . En CD a 5 �lecR0 Fluorescent T8 Rapid Start 3 32 IS 76.0 X 10 760 A8 (4) 4 ft Fluorescent T8 ElecRO F32TR 4 91.0-K— 186 16,926 B 150w Wall Mount Incandescent 150W 1 150.0,K3 450 D 705w Incandescent 1 701 70.01 X 18 1.260 D TRACK LIGHT TYPE D H 2) 4 ft Fluorescent T8 Rapid Start IecRO K P) 4 ft Fluorescent T8 Rapid Start IecRO L �) 4 ft Fluorescent T8 Rapid Start IecRO O 100w Metal Halide Mag PAGE TOTAL 24,781 BUILDING TOTAL (sum of all pages) 24,781 PORTABLE LIGHTING (From LTG-3-C)� CONTROL CREDIT (From LTG -4-C) ADJUSTED ACTUAL WATTS 24, 781 4.2 by EnergySoft User Number: 3193 Job Number. Page:4 of 6 LINE VOLTAGE. TRACK LIGHTING WORKSHEET LTG -9-C PROJECT NAME P o v PW -s m A iu( F --r PL AC C DATE TRACK # LINEAR FEET OF B x C TOTAL RATED WATTAGE OF OF ✓ ❑METHOD 1 -'VOLT-AMPERE (VA) RATING OF THE BRANCH CIRCUIT(S) FEEDING THE TRACKS A B A (continued) B (continued) C BRANCH CIRCUIT VOLT-AMPERE (VA) RATING BRANCH CIRCUIT VOLT-AMPERE (VA) RATING NAME OR ID OF THE BRACHK CIRCUIT NAME OR ID OF THE BRACHK CIRCUIT ADD BOTH SU& TOTALS r= a.1� " TOTAL' : ✓ ❑METHOD 3 - ONLY TO BE USED WITH INTEGRAL CURRENT LIMITER 3 (a) ❑ ✓ HERE IF THE CURRENT LIMITER IS CERTIFIED TO THE COMMISSION (DEVICE MUST BE CERTIFIED TO THE COMMISSION TO USE THIS METHOD TO QUALIFY FOR TIER 1 ALL OF THE FOLLOWING STATEMENTS (3b & 3C & 3d) MUST BE TRUE. IF ANY ARE FALSE THEN SUB TOTAL SUB TOTAL 3 (c) The track in not connected to a dimmer of any kind, including preset controller or dimmer modules that have TOTAL 3 (d) At time of inspection the actual installed wattage of high efficacy luminaires is equal to or more than 7.5 watts per ✓arMETHOD 2 - USE THE, HIGHER OF: 45 WATTS / LINEAR FOOT OF TRACK — OR TOTEIL RATED WATTAGE OF ALL OF ALL LUMINAIRES A B C D E. F LARGER TRACK # LINEAR FEET OF B x C TOTAL RATED WATTAGE OF OF QFt NAME TRACK !LF (w) ALL LUMINAIRES (D or E) ..92 45 :::;x4.140 1.2 Dom~~. 4.140 45 45 r= a.1� " TOTAL' : ✓ ❑METHOD 3 - ONLY TO BE USED WITH INTEGRAL CURRENT LIMITER 3 (a) ❑ ✓ HERE IF THE CURRENT LIMITER IS CERTIFIED TO THE COMMISSION (DEVICE MUST BE CERTIFIED TO THE COMMISSION TO USE THIS METHOD TO QUALIFY FOR TIER 1 ALL OF THE FOLLOWING STATEMENTS (3b & 3C & 3d) MUST BE TRUE. IF ANY ARE FALSE THEN USE TIER 2 VALUE' 3 (b) The specifications and installation exclusively include only high efficacy luminaires as defined in § 150 (k)1.. 3 (c) The track in not connected to a dimmer of any kind, including preset controller or dimmer modules that have programmable load types. 3 (d) At time of inspection the actual installed wattage of high efficacy luminaires is equal to or more than 7.5 watts per liner foot. USE THE HIGHER OF: VA RATING OF INTERGRAL CURRENT LIMITER, 15 WATTS PER LINEAR FOOT FOR TIER 1, OR 25 WATTS PER LINEAR FOOT FOR TIER 2 A B C D E F G H 1 J 'Tier 1" if b, LINEAR VA RATING CHOOS c, and d = TIER I - FEET OF_ E TRACK # ✓ IF 3 (b) ✓ IF 3 (c) ✓ IF 3 (d) Tru Other 15 (WI TIER 2 , OF TRACK TOTAL Wath CLIMITER ' R OFE OR NAME = TRUE = TRUE =TRUE Enter -nor 2' 25 RI ft F x G H or I ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑` ❑ 1 ❑ TOTALWATTS 2005 Residential Compliance Forms April 2005 INDOOR LIGHTING POWER ALLOWANCE LTG - PROJECT NAME DATE COST PLUS MARKET PLACE 1 11/14/2006 BUILDING CATEGORY (From Section 146 Table 146-6) WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS Comp Bldg Retail and Wholesale 1.50 17 521 26,282 AREA CATEGORY METHOD - CONDITIONED SPACES AREA CATEGORY (From Section 146 Table 146-C) WATTS AREA ALLOWED PER SF (SF) WATTS PAGE TOTAL D D BUILDING TOTAL AREA WATTS TOTAL ALLOWED WATTS I (From LTG -6-C or from computer run. CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG -1 - PROJECT NAME ---[DATE COST PLUS MARKET PLACE 11/14/2006 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptan tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type require a test, list the equipment description and the number of systems to be tested in parentheses. The N number designates the Section in the Appendix of the Nonresidential ACM Manual that describes th test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, desig professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building departmen that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of 10-103(b) and Title 24 Part 6. Test Description Test Performed B ❑ LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing User Number: 3193 Job Number: Paoe:3 of 6 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LT PROJECT NAME DATE COST PLUS MARKET PLACE 11/1412006 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑X COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 26,282 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROLLOCA (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Check if 4.2 by EnergySoft User Number: 3193 Job Number: Paget of 6 INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 24.781 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER r 24,781 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑X COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 26,282 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROLLOCA (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Check if 4.2 by EnergySoft User Number: 3193 Job Number: Paget of 6 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C PROJECT NAME DATE COST PLUS MARKET PLACE 11/14/2006 PROJECT ADDRESS LA QUINTA, CA Building Permit # PRINCIPAL DESIGNER - LIGHTING TELEPHONE SOTHOL ROEUNG Checked by/Date DOCUMENTATION AUTHOR TELEPHONE S.Y. Lee Associates 818 244-4337 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 8/2/05 17,521 sq.Ft. 7 BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUEST ROOM ® CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION METHOD OF LIGHTING ® COMPLETE BUILDING ❑ AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accur to and complete. DOCUMENTATION AUTHOR SIGNATURE SOTHOL ROEUNG TU3, © Al The Principal Lighting Designer hereby certifies that the proposed ing design represented in this set of construction docum is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 1 130 - 132, 146, 148 & 149 of Title 24, Part 6. ❑ The plans & specifications meet the requirements of Part 6 (Sections 10-103a). ❑ The installation certificates meet the requirements of Part 6 (10-103a 3). ❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) �( I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person �V responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this documen as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions C de Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE DAT LIC. # SOTHOL ROEUNG I �o o lta2 LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measure LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included ®LTG -1-C, Parts 1 of 4 and 2 of 4Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals []LTG -1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed 10LTG-1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed ®LTG -2-C: Indoor Lighting Schedule ❑LTG -3-C: Portable Lighting Worksheet []LTG -4-C: Lighting Controls Credit Worksheet ®LTG -5-C: Indoor Lighting Power Allowance []LTG -6-C: Tailored Method Worksheet []LTG -7-C: Room Cavity Ratio Worksheet []LTG -8-C: Common Lighting Systems Method Worksheet ❑LTG -9-C: Line Voltage Track Lighting Worksheet EnergyPro 4.2 by EnergySoft User Number. 3193 Job Number. Page:1 of 6 nts vith LIGHTING MANDATORY MEASURES LTG -M PROJECT NAME 1 DATE COST PLUS MARKET PLACE 11/14/2006 DESCRIPTION Designer Enforcement FE131(d)1For every floor, all interior lighting systems shall be equipped with a separate auton atic control to shut off the lighting. This automatic control shall meet the requirements Section 119 and may be an occupancy sensor, automatic time switch, or other devi e capable of automatically shutting off the lighting. M 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. D111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. a132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. FX 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. MV 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. ® 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. x EnergyPro 4.2 by EnergySoft User Number: 3193 Job Number. Pa e:6 of 6 CERTIFICATE OF COMPLIANCE (Part 1 of 2) OLTG-I-C PROJECT NAME: COST PLUS MARKET PLACE DATE 8/6/2006 PROJECT ADDRESS: LA QUI NTA, CA incorporated in schedules on the plans. PRINCIPAL DESIGNER — LIGHTING: SOTHOL ROEUNG % : TEL PHO �81) 244-4337 1. Use LTG -1—C 9 the project consists solely of indoor signs Building Permit # DOCUMENTATION AUTHOR: SOTHOL ROEUNG TELEPHONE: 818 244-4337 righting. Checked by Dote Enforcement Agency Use GENERAL INFORMATION ® OLTG-2—C DATE OF PLANS: 8/6/2006 OUTDOOR LIGHTING ZONE ( v/ One) ❑ LZ1 ❑ LZ2 ® LZ3 ❑ LZ4 FUNCTION TYPE ® OUTDOOR LIGHTING ❑ OUTDOOR SIGNS ❑ INDOOR SIGNS ❑ OLTG-4—C PHASE OF CONSTRUCTION NEW CONSTRUCTION ❑ ADDITIONS ❑ ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENT AUTHOR SOTHOL ROEUNG SIGNATURE: DATE: $/6/2006 The Principal Lighting Designer hereby certifies that the proposed outdoor lighting and signs design - in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been ,designed to .meet the lighting requirements contained in the applicable parts of Sections 110, 119, 130-132, 146, & 149 of Title 24, Part 6. Please \/ one: ® I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 -and 6737.1. (These sections of the Business and Professions Code are printed in full in the Manual.) INSTRUCTIONS TO APPLICANT OUTDOOR LIGHTING COMPLIANCE & WORKSHEETS ( V box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual pulbished by the California Energy Commission. ® OLTG—I—C Certificate of Compliance. Required on plans for all submittals for outdoor righting. Part 2 of 2 may be incorporated in schedules on the plans. Either LTG -1—C or OLTG—I—C may be used for signs as follows: 1. Use LTG -1—C 9 the project consists solely of indoor signs 2. Use LTG -1—C if the project consists of indoor righting, and outdoor or indoor signs, but no other outdoor righting. 3. Use OLTG—I—C N the project consists solely of outdoor signs ® OLTG-2—C 4. Use OtTG--1—e if the project consists of outdom lighting, wild indoor or outdow 6igII3. but no other indoor UGHTI*"PLUWCE SUMMARY. Applicable Parts required for ALL outdoor righting allowances (Except for Signs) ❑ OLTG-3—C AREA CALCULATIONS WORKSHEETS. Applicable parts required for all outdoor area calculations. ❑ OLTG-4—C SIGN LIGHTING COMPLIANCE. Required for all internally and extemolly illuminated signs. for both indoor and outdoor I alone. 2005 Nonresidential Compliance Forms April 2005 CERTIFICATE OF COMPLIANCE (Part 2 of 2) OLTG-I-C PROJECT NAME: COST PLUS MARKET PLACE LIGHTING SCHEDULES ON PLANS SHOW THAT OUTDOOR LIGHTING MEETS ALLOWED LIGHTING POWER X Lighting power allowances for general site illumination on OLTG-2—C Part 1 of 4 ❑ Not Applicable ® fighting power allowances for local ordinances or for security multipliers on OLTG-2—C Part 2 of 4 ❑ Not Applicable ❑ Lighting power allowances for specific applications, other than vehicle service stations with canopies on OLTG-2—C Part 3 of 4 ® Not Applicable ❑ Lighting power allowances for vehicle service station canopies on OLTG-2—C Part 4 of 4 ® Not Applicable ❑ Sign lighting compliance on OLTG-4—C Not'Applicoble MANDATORY MEASURES ON PLANS SHOW THAT OUTDOOR LIGHTING MEETS OUTDOOR LIGHTING CONTROLS AND EQUIPMENT Indicate location on plans of Note Block for Mondatory Measure ® Installed lighting power has been determined in accordance with ? 130(c)1 ❑ Not Applicable ® All permanently installed luminaires with lamps rated over 100 watts either have a lamp efficacy of at least 60 lumens per watts or are controlled by a motion sensor ? 132(a) ❑ Not Applicable �( All Luminaires with lamps rated greater than 175 watts in hardscope areas, including parking lots, building entrances, canopies, and all outdoor sales areas meet the Cutoff Requirements of ? 132N ❑ Not Applicable ® All permanently installed outdoor lighting meets the Control Requirements of ? 132(c)1 ❑ Not Applicable ® Building facades, parking lots, garages, canopies, and outdoor soles areas meet the Multi—Level Lighting Requirements of ? 132(c)2 ❑ Not Applicable MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION CONTROL IDENTIFICATION CONTROL TYPE Auto Time Switch/Photosensor, etc AREA CONTROLLED NOTE TO FIELD EIEC7RNA ROOM PANEL SCHEDULE PROGRAMMABLE TIME SW. AND PHOTOCELL BUILDING EXTERIOR 1 1 DIMMING PANEL IS EQUIPED WITH STATE OF CALIFORNIA TITLE 24 ENERGY REGULATION CERTIFIED 'APPROVED' PROGRAMMABLE TIME CLOCK CAPABILITIES FOR CONTROL OF OUTDOOR LIGHTING. ILI;GHTING COMPLIANCE SUMMARY (Part 2 of 4) OLTG-2-C NAME: COST PLUS MARKET PLACE DATE: 08/06/06 Total Allotted Watts: 1,301 Total Installed Watts: 1,196 Checklist LIGHTING POWER ALLOWANCES - LOCAL ORDINANCE TABLE 147-C) OR SECURITY MULTIPLIERS (TABLE 147-D) Allotted Watts Luminaire Lamps/Ballasts Installed Watts A B C D E F G H I J K L M N O P Li hting applications Cat ego � B (0 0) o �y O ".2 a v �, D 'o K .C-. � a) M c C1 0 _. D x a C� W x w x o 0 o W � 3 C) B 0 m o o Description CD `� �_ o 3 v r Z C C 3� v Cr Boo o cu �, pp Z C C 3 m 3 �. CD m o r- C C< 3. m m n 0 ;z Z C 5 0 �. m Eno CD � a x 0) O MEI WALKWAY HOD (1) 2,628 0.17 0.07 447 M BUILDING MTD LTS WALKWAY - 100 MH 1 100 1 115 X 1 115 Z BUILDING MTD LTS (WALKWAY) - 42 -TRT 1 42 1 46 X 5 230 BU,LDIG ENTRANCE 472 0.7 0.07 330 Z1 BUILDING MTD LTS WALKWAY - 42 TRT 1 42 1 46 X 6 276 DRIVEWAY 3,495 0.15 0.07 524 M BUILDING MTD LTS WALKWAY - 100 MH 1 1 100 1 1 115 X 5 575 Total Allotted Watts: 1,301 Total Installed Watts: 1,196 Checklist EXCEPTION 1 TO § 147 c 1 B - There is a law through a local ordinance requiring specific light levels, and therefore, the power allowances in Table 147-C were used. uompuance corms April 2005