Loading...
06-3475 (RC) LTC, ~ TITLE 24 REPORT Title 24 Report for: Z- Pizza The Pavillion La Quinta, CA Project Designer: Torres Architects 2421 W 205th Street Suite 200 Torrance, CA 90501 (310) 320-6285 Report Prepared By: Jon E. De Cuir, P.E. Jon E. De Cuir - Civil Engineer • 5924 Pacific Coast Hwy. #1 Redondo Beach, CA 90277 (310) 375-8049 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Job Number: 06119 Date: 12/20/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by EnergySoft Job Number: 06119 User Number: 5882 ' TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form LTG -1-C Certificate of Compliance 3 Form LTG -2-C Indoor Lighting Schedule 7 Form LTG -4-C Lighting Controls Credit Worksheet 8 Form LTG -5-C Indoor Lighting Power Allowance 9 Form LTG -MM Lighting Mandatory Measures 10 , I EnergyPro 4.2 by EnergySoft Job Number: 06119 User Number. 5882 �CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C PROJECT NAME DATE Z- Pizza 12/20/2006 PROJECT ADDRESS ) --°--— ' The Pavillion La Quinta_ PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit # _ Torres Architects (310) 320-6285 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Jon E. De Cuir - Civil Engineer 310 375-8049 EnforcementA enc" Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 09.25.06 1,417 Sq.Ft. 15 BUILDING TYPE 0 NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUEST ROOM ❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION ALTERATION METHOD OF LIGHTING ❑ COMPLETE BUILDING ❑X AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certific a applies o o building lighting requirements. The documentation preparer hereby certifies that the document i n is to And complete. DOCUMENTATION AUTHOR SIGNAT DATE Jon E. De Cuir, P.E. 20 061c, 01� The Principal Lighting Designer hereby certifies that the propo d building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, wi wthe specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 - 132, 146, 148 & 149 of Title 24, Part 6. 21"The plans & specifications meet the requirements of Part 6 (Sections 10-103a). ❑The installation certificates meet the requirements of Part 6 (10-103a 3). The operation & maintenance information meet the requirements of Part 6 (10-103c). Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) D-Kereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under -the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE DATE LIC. # Torres Architects LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures V LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included 19LTG-1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals IR LTG -1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed 19 LTG -1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed IR LTG -2-C: Indoor Lighting Schedule 0LTG-3-C: Portable Lighting Worksheet XLTG-4-C: Lighting Controls Credit Worksheet ® LTG -5-C: Indoor Lighting Power Allowance ❑LTG -6-C: Tailored Method Worksheet ❑LTG -7-C: Room Cavity Ratio Worksheet El LTG -8-C: Common Lighting Systems Method Worksheet ❑LTG -9-C: Line Voltage Track Lighting Worksheet EnergyPro 4.2 by EnergySoft User Number: 5882 Job Number: 06119 Page:3 of 10 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -17 (PROJECT NAME DATE Z- Pizza 12/20/2006 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ❑X AREA CATEGORY METHOD (From LTG -5-C) ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER INSTALLED ALTERNATE COMPLIANCE WATTS ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 1.497 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 60 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 1,436 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ❑X AREA CATEGORY METHOD (From LTG -5-C) ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER ALLOWED WATTS F71,736 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) M CONTROL IDENTIFICATION I tIvvt,E CLCCk CONTROL TYPE (Auto Time Switch, Dimming, etc.) Ars Check if SPACE CONTROLLED Daylighting L� - S®eck' :NOTE TO FIELD CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG-1-6 PROJECT NAME DATE Z- Pizza 12/20/2006 CONTROLS FOR CREDIT IN CONDITIONED AND UNCONDITIONED SPACES CONTROL LOCATION (Room # or Dwg. #) Dining Dining Front Kitchen CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) Dimming - Manual Dimming - Manual Dimminq - Manual LUMINAIRES CONTROLLED LUMINAIRESTYPE # OF C 3 D 3 E 7 NOTE TO FIELD EnergyPro 4.2 by Energysoft User Number: 5882 Job Number. 06119 Page:5 of 10 CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG-1-C PROJECT NAME Z- Pizza DATE 12/20/2006 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: ® LTG-2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Cor%-'ra-e*&,,' Equipment requiring acceptance testing O LTG-3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.2 by EnergySoft User Number: 5882 Job Number: 06119 Page:6 of 10 1 N O r (u a_ FH N O N N W a 0 0) O O to M 0 d a 'Cl- Ln O O 00 a It O V7 to It ° o o IL Installed CD M N J Z p C3 W H Watts co JO (9 D Z J Q (G x 1) 2 0 rn m to a o U E M 3. Number !C-1) N l M M 0 — of Luminaires M CEC X X X C= Default? X X O 999 O Watts 00 LO O O N 0 per N M un u7 (D Luminaire Number of O O LL Ballast per `— Luminaire M LO O O N Wafts N M U*) U*) M W per to Lamp M m Number of N 0 Lamps per Q. Luminaire E J � U Lamp Type N of 0_ 2 CO c I,�o, U C:, Ln 2 _" LL m 3 c 0 � a n2 d L crn U to N a Ll _ W 00 y C .� •� cl Q CL O _m J C - N C > m 2 5 > C7 LL LOJ O C CCN R O �N. m E Q U 0 W Z (D 0) O O to M 0 d a N Go LO M0) E w w N v a w ° o o IL J Z p C3 W H co JO (9 D Z J Q H 2 0 rn m a o U E z' 0 N Go LO M0) E w w N v LIGHTING CONTROLS CREDIT WORKSHEET (Part 1 of 2) LTG-4-C CONTROL CREDITS FOR CONDITIONED SPACES PROJECT NAME DATE Z- Pizza 12/20/2006 A B C D iE I F I G H I J ROOM # ZONE ID CONDITIONED AREAS LIGHTING CONTROL DESCRIPTION PLAN REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR= CONTROL CREDIT WATTS (H X 1) WINDOW WALL RATIO GLAZING VLT SKYLIGHT EFFECTIVE APERTURE' Dining Dimming - Manual C 350 105 0.10 10 Dining Dimming - Manual D 350 150 0.10 15 Front Kitchen Dimming - Manual E 369 350 0.10 35 1) From Equation 146-A 2) From Table 146-A PAGE TOTAL BUILDING TOTAL Enter in LTG -2-C: Lighting Control Credit EnergyPro 4.2 by EnergySoft User Number. 5882 Job Number: 06119 Page:8 of 10 1 JINDOOR LIGHTING POWER ALLOWANCE LTG -5-C PROJECT NAME Z- Pizza DATE 12/20/2006 ALLOWED LIGHTING POWER Choose One Method COMPLETE BUILDING METHOD - CONDITIONED SPACES WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From Section 146 Table 146-13) AREA CATEGORY METHOD - CONDITIONED SPACES AREA (SF) ALLOWED WATTS AREA CATEGORY (From Section 146 Table 146-C) WATTS PER SF Dining 1.10 350 385 Corridor/Restroom/Support 0.60 356 214 Kitchen, Food Preparation 1.60 711 1,138 PAGE TOTAL BUILDING TOTAL 1 ,417 1,417 AREA 1,736 1,736 WATTS TAILORED METHOD - CONDITIONED SPACES TOTAL ALLOWED WATTS O (From LTG -6-C or from computer run.) UNCONDITIONED SPACES Complete Building and Area Catagory Methods Category (From Section 146 Table 146 -B&C) WATTS PER SF AREA (SF) ALLOWED WATTS PAGE TOTAL BUILDING TOTAL 011 01 011 AREA 01 WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) 0 EnergyPro 4.2 by EnergySoft User Number: 5882 Job Number: 06119 Page:9 of 10 1 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME DATE Z- Pizza 12/20/2006 DESCRIPTION Designer Enforcement XJ §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. X] § 131 (d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. FXJ §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. X❑ §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. R §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.2 by EnergySoft User Number: 5882 Job Number. 06119 Page:10 of 10