Loading...
BCOM2014-1012 Certificate of Compliancez 1 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06113) CALIFORNIA ENERGY COMMISSION'r�°" CERTIFCATEOFCCMPLIANCE USERINSTRUMNS NRCC-LTI-01T Indoor ig ting age 1 ot 5J Project Name: WABA GRILL Date Prepared: 07-30-14 Climate one: Conditioned FloorArea: Uncoiitione F oorArea: General n ormation Build mg I ype: ❑ Schools 6c1 ❑ NonresidentialHigh Relocatable Public Schools Ise es entia ❑ Conditioned Spaces p ote to ❑ Uncmditiond Spaces PhaseofConstruction: ❑ New Construction ❑ Additia ❑ Alteration MethodofCompliance: ❑ Complete Building 6d AreaCategoy ❑ Tailored LIGHTINGCOMPLIANCDOCiJMENTS(select yes for each docume t included) Fordetoiled instrucfonson the use of thisandall EnergyffficiencyStandardronpliance documentsr�er to theNoniesidentbl ManuolpudishedbytheColifania E YES NO FORM TITLE NRCC-LTI-01-E Ce-tificateofCompliance AIIPagesrequiredonplansforallsubmittals. NRCC-LTI-02-E LightingControlsjCertificateof CompliancpandPAFCalculatbn. All Pages requiredon plansforall submittals. NRCC-LTI-03-E Indoor Lighting PowerAlloNance NRCC-LTI-04-E Tailored Method Worksheets NRCC-LTI-05-E Line VoltageTrack Lighting Worksheets ummary OT Anowea Lignting rower onclitioned and Unconditioned space Lighting must not be combined for compliance Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Watts Installed Lighting Installed lighting 1. NRCC LTI 01 E, page 4 + 1584 NRCC LTI 01 E, page 4 + PORTABLE ONLY FOR OFFICES 2' NRCC LTI 01 E page 3 + 3 Minus Lighting Control Credits Minus Lighting Control Credits NRCC LTI 01 Ea e 2 NRCC LTI 01 E page 2 4 Adjusted Installed Lighting Power _ Adjusted Installed Lighting Power _ (row 1 plus row 2 minus row 3) – (row 1 minus row 3) CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING Fti U-NRCC-LTI-01-E (Revised 06113) CALIFORNIA ENERGY COMMISSION ' CERTIFICATE OF COMPLIANCE USER INSTRUCTIONS NRCC LTI 01 E Indoor Lighting (Page 2 of 5) Project Name: WARA GRILL Date Prepared: 07-30-14 S. Complies ONLY if Installed Allowed Complies ONLY if Installed Allowed NO 6. Allowed Lighting Power Conditioned NRCC LTI 03 E, page 1 X Allowed Lighting Power Unco nditio ned NRCC LTI 03 E, page 1 NRCI LTI 01 E Must be subm itted for all bui (dings Declaration of Required Installation Certificates Declare by selecting yes for all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title x X NRCA LTI 02 E Must be submitted for occupancy sensors and automa tic time switch controls. NRCI LTI 01 E Must be subm itted for all bui (dings Field Inspector NRCA LTI 03 E Must be submitted for automatic daylight controls. NRCI LTI 02 E Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), Field Inspector X NRCA LTI 04 E Must be submitted for demand responsive lighting controls. to be recognized for compliance. NRCI LTI 03 E Must be submitted for a line voltage track lighting integral current limiter, or for a supplementary Field Inspector X overcurrent protection panel used to energize only line voltage track lighting, to be recognized for compliance. x NRCI LTI 04 E Must be submitted for two interlocked systems serving an auditorium, a convention center, a Field Inspector conference room, a multipurpose room, or a theater to be recognized for compliance. X NRCI LTI 05 E Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. Field Inspector NRCI LTI 06 E Must be submitted for additional wattage installed in a video conferencing studio to be recognized for Field Inspector X compliance. Declaration of Required Certificates of Acceptance Decla re by checking all of the Certificates of Acceptance that will be submitted. (Retai n copies and verify forms are completed and signed.) YES NO Form/Title x NRCA LTI 02 E Must be submitted for occupancy sensors and automa tic time switch controls. Field Inspector NRCA LTI 03 E Must be submitted for automatic daylight controls. Field Inspector NRCA LTI 04 E Must be submitted for demand responsive lighting controls. Field Inspector CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 r .. STATE OF CALIFORNIA INDOOR LIGHTING RON CEC-NRCC4.TI.01-E (Revised 06113) CALIFORNIA ENERGY COMMISSION CERTIFCAIE OFCCMPLIANCE USERINSTRUMNS NRCC-LTI-01-E Indoor Lighting . (Page 4 of 5 Project Name: WABA GRILL Date Prepared: 07-30-14 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Space. Installed Lighting Power listed on this Lighting Schedule is only for: ® CONDITI(NEDSPACE ❑ U NCCN DITION E [SPACE C. INDOORLIGHTINGGHEDULE and FIELDINSPECTIORNERGYCHECKLIST uminalr c e u e InstalledNatts Location Fieldln ecmrl A B C D E F G H How wattage was determined a rn c o d rn Complete Luminaire Description 3. o o a N ro E E I.e, 31am fluorescent troffer, (' p �. z — "°' Primary Function area in which z " F32T8 one dimmable electront ballast) '° � � — = E CD -` a these luminaire are installal Pass Fail PENDANT LTG (1) aW OMMIC BALLAST 28 ❑X ❑ 4 112 8 RECESS DOWN (1) CF26 ELECTRONIC BALLAST 28 ® ❑ 6 168 C PENDANT L70 (1 CM ELECTRONIC BALLAST 28 ® ❑ 3 84 D 2X2 FLRST (2)n778 ELEMONC BAUAST 33 ❑ 16 528 E 8' TRACK LTG ❑ ❑ 120 F LED CONE LTG LED 1W/FT 1W/FT ® ❑ 28 28 H WALL SCONCE (1) CF13 ELECTRONIC BALLAST 16 ® ❑ 1 16 1 LED 7RACK VG ❑ ❑ 360 G 4' MST (1)F2875 ELEMONC BALLAST ® ❑ 168 Entersumtoial of all pagesinto INSTALED WATTTAGETOTAL: 1584 NRCC LTI 01 E; Paget CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E Revised 06/13 CALIFORNIA ENERGY COMMISSION f6 CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC- LTI- 01-E Indoor Lighting (Page 5 of 5) Project Name: WABA GRILL Date Prepared: 07-30-14 DOCUMENTATIO N AUTHOR'S DECLARATI ON STATEMENT Documentabn AuthorNarre GARY WANG Documentatmn AuthorSigrature: Campany: GARY WANG & ASSOCIATES. INC. SigmtureDate: 07-30-14 Address 1255 CORPORATE CEN70 DR. PH 8 CEA/HERSCa6ficationldentiication(ifappliader City/State/Zip: MONTEREY PARK CA 91754 Phone: 828-288-8898 RESPONSIBLBERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Complian is required to be included with the documentation the builder Drovides to the building owner at occupancy. ResporsideDaignerNarre GARY WANG ResponsilieDesignerSignature: Company GARY WANG & ASSOCIATES. INC. DateSigred 07-30-14 Address 1255 CORPORATE CENTER DR. PH 8 Licenm: C-32589 City/State/Zip: MONTEREY PARK, CA 91754 Phone: 828-288-8898 CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS -EC -NRCC-LTI-01-E (Revised 06113) CALIFORNIA ENERGY COMMISSION CERTIFI CATE OF COMPLIANCE NRCC LTI 02 E Indoor Lighting -Lighting Controls (Page 1 of 5) Project Nan: WABA GRILL Date Prepared 07-30-14 The NRCC LTI 02 E shall be used to document all mandatory and prescriptive lighting controls that are applicable to the project. A. Ma ndatory Lighting Control Declaration Statements Indicate if the measure applies: YES NO ControRequiement Lighting shall be controlled by self contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with Section 110.9. X Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with Section 130.4(b). X One or more Track Lighting Integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with 10.9 and An Installation Additionally, an Installation Certificate shall be submitted in accordance with Section 130.4(b). A Track Lighting Supplementary Overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.3. Additionally, an Installation Certificate shall be installed in accordance with Section 130.4(b). X All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with Section 130.1. X All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, X and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, ornamental and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. X The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the multi level lighting control requirements in accordance with Section 130.1(b). X All installed indoor lighting shall be equipped with controls that meet the applicable Shut OFF control requirements in Section 130.1(c). X Lighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans. Lighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in accordance with Section 130.1(e). Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance HERS Provider: June 2013 STATE OFCAUFORNIA Lighting Control Schedule INDOOR LIGHTING - LIGHTING CONTROLS PAF Credit Calculation Z CEC-NRCC-LTI-01-E Revised 06113 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC LTI 02 E Indoor lighting Lighting Controls (Page 2 of 5) Project Nam e: WARA roll I Date Prepared: 07-30-14 A separate document must be filled out for Conditioned and Unconditi oned Spaces. This page is used only for the following: E] CONDITIONED SPACES ❑ UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST Lighting Control Schedule Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for PAF Credit Calculation Z --I =;i rD r -r rD tD rD Q CD normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in r— 7 ? o N iZ -V T accordance with Section 130.4.(a). The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut OFF A B controls, and demand responsive controls. A separate document must be filled out for Conditioned and Unconditi oned Spaces. This page is used only for the following: E] CONDITIONED SPACES ❑ UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST Lighting Control Schedule Standards Complying With 1 (wall that apply, or enter if Exempted) PAF Credit Calculation Z --I =;i rD r -r rD tD rD Q CD T (D tin rD r. r— 7 ? o N iZ -V T !) >' x A B C D E I F G I H I I J K L M N 0 Location in Building Type/ Description of Lighting Control (i.e.: occupancy sensor, automatic time switch, dimmer, automatic daylight, etc # of Units o a 0 0 = 0 0 V 0 0 KITCHEN TIME CLOCK 1 1 1 141 -1 11 H Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CERTIFCAIEOFCCMPLIANCE NRCCLT102E Indoorl-AtinR, LlRWRContols (PaRe3of51 ProjectName: WABA (TRILL I DatePrepared 07-30-14 INSTALED WATTS°AGETOIAL: IF MULTIPE PAGES ARE USED,ENIER SUMTOTALOF ALLPAGESH ERE: 1. §1330.10) = Manual area controls; §130.0(b) = Multi Level; §130.1(c) = Auto Shut Off; §130.1(c) = Mandatory Daylight; §130.1(e) = Demand Responsive; §140.6(d) = Additional lighting controls installed to earn a PAF; §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check Table 140.6 Afar correct Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate Is also required to be filled out, signed, and submitted. Registration Number: . Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 Documentation AuthorName: GARY WANG Documentatbn Authorsigreture: Company: GARY WANG & ASSOCIATES, INC. SigratureDate: 07-30-14 Address: 1255 CORPORATE CENTER DR. PH 8 CEA/HERSCatificabonldentificatior(ifappliadek City/State/Zip: MONTEREY PARK. CA 91754 Phone: 828-288-8898 RESPONSIBLPERSON'S DECLARATIM STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certifica to of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder ovides to the buildingowner at occupancy. Responsible Designer Name: GARY WANG Responsible Designer Signatur . Company : GARY WANG & AMOATES, INC. Date Signed: 07-30-14 Address: 1255 CORPORATE CENTER DR. PH 8 ucense: C-32569 City/state/zip: MONTEREY PARK, CA 91754 Phone: 626-288-6898 Registration Number: . Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance Indoor Lighting Power Allowance (Page 1 of 4) Project Name: nABA GRILL Date Prepared: 07-30-14 LOW® LIGHTINGPOWER(ChoseMethod) AseparatepagemustbefilledutforCondkionedandUnconditionedpaces.Thispageis onlyfor: IN CONDITIONED spaces ❑ UNCONDITIONED spaces A. SUMMARY TOTALS OF LIGHTING POWER ALLOWANCES If using Complete Building Method for compliance, use only the total in column (a) as total allowed building watts. If using Area Category Method, Tailored Method, or a combination of Area Category and Tailored Method for compliance, use only the total in column (b) as the total allowed buildine watts 1. Complete Building Method Allowed Watts. Documented in section B of NRCC-LTI-03-E (below on this page 2. Area Category Method Allowed Watts. Documented in section C 1 of NRCC-LTI-03-E (below on this age) 3. Tailored Method Allowed Watts. Documented in section A of NRCC LTI 04 E TOTAL ALLOWED BUILDING WATTS. Enter number into correct cell on NRCC-LTI-01, Page 2, Row 1 ❑ Check here if building contains both conditione d and unconditioned areas. B. COMPLETE BUILDING METHOD LIGHTING POWER ALLOWANCE A B JC D TYPE OF BUILDING (From §140.6 Table 140.6-B) WATTS PER (ft4 X COMPLETE BLDG. AREA = ALLOWE D WATTS TotalArea: ilk Total Watts. Enter Total Watts into section A, row 1(Above on this page) C-1 AREA CATEGORY METHOD TOTAL LIGHTING POWER ALLOWANCES (C-2 plus C-3) Watts Total from section C 2 . Total from section C 3 . Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CERTIFICATE OF COMPLIANCE NRCC LTI 03 E Certificate of Compliance Indoor Lighting Power Allowance (Page 2 of 4) Project Name: WMA GRILL Date Prepared: 07-30-14 Total Watts. Enter Total Watts into section A, row 2 (Above on this page) A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: C3 CONDITIONED spaces E3 UNCONDITIONED spaces C- 2 AREA CATEGORY METHOD GENERAL LIGHTING POWER ALLOWANCE Do not include portab le lighting for offices. Portable lighting for offices shall be documented only in section B of NRCC LTI 01 E. Separately list lighting for each primary function area as defined in § 100.1 of the Standards. A B X C = D AREA CATEGORY (From §140.6 Table 140.6-C) WATTS PER (ft4 AREA (ft4 ALLOWED WATTS Location in Building Primary Function Area per Table 140.6 C FOOD PREP. 731 1170 RESTROOM 0.6 65 39 DINING AREA 1.1 561 639 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE � :FC•NRCC-LTI-03•F (Revised 06111) CALIFORNIA FNFRGY COMMIWON CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance Indoor Lighting Power Allowance (Page 3 of 4) ProjedNarm: WABA GRILL DatePrepared 07-30-14 TOTALS I 1377 I1848 Enter sum total Area Category allowed watts into section C 1 of NRCC-LTI-03-E (this compliance form) WATTS I A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: I CONDITIONED spaces UNCONDITIONED spaces C-2 AREA CATEGORY METHOD Additional lighting Wattage Allowance (from Table 140.6 C Footnotes A B CZ D E F G Primary Function Sq Ft or linear ft 1 Additional Watts Allowed Wattage Allowance B x C Description (s) and Quantity of Special Luminaire Types in each Primary Function Area Total Design Watts 3 ALLOWED WATTS Smaller of D or F t TOTALS Enter into TOTAL AREA CATEGORY METHOD ADDITIONAL ALLOWANCES Section C 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC•LTI-03-E Revised 06113 CALIFORNIA ENERGY COMMISSION s CERTIFICATE OF COMPLIANCE NRCC LTI 03 E Certificate of Compliance Indoor Lighting Power Allowance (Page 4 of 4) ProjectName: WABA GRILL Date Prepared 07-30-14 1. Use linear feet only for additional allowance for white board or chalk board. All other additional Area Category allowances shall use watts per square foot. 2 . Additional watts are available only when allowed according to the footnotes on bottom of Table 146 C, which include: Specialized .task work; Ornamental lighting; Precision commercial and industrial work; Per linear foot of white board or chalk board; Accent, display*and feature lighting; and Videoconfere ncing Studio lighting.. 3. Luminaire classification and wattage shall be determined in accordance with §130.0(c) of the Standards. 1. 1 certify that this Certeficate of Compliance documentation is accurate and complete, Documentati on Author Name: GARY WANG Documentati on Author Signature: Company: GARY WANG & ASSOCIATES, INC. Signature Date: 07-30-14 Address: 1255 CORPORATE =70 0R. PH 8 CEA/ HERS Certification Identification (if applicable): City/State/Zip: MONTEREY PARK, CA 91754 Phone: 626-288-6898 RESPONSIBLPERSON'S DEQARATIM STATEMENT I certify the following under penalty ofperjury,under the laws of the State of California: 1. Thein ormationprovidedonthisCerti icateofCompliance istrue and correct. 2. lam eligible under Division of the Business and ProfessionsCode to acceptresponsibi lityfor the buildingdesign or system design identified on this Certificateof Compliance (responslbledesigner). 3. The energy features and performancespecifications,materials,compon(nts, and manufactu reddevicesfor the bui Idingdesign or system design identified on this Certificateof Complianceconformto the requirementsof Title 24, Part land Part 6 of the CaliforniaCode of Regulations 4. The buildingdesign featuresor system design features identified on this Certificate of Com plia ncea re consist(nt with the informationprovideclon otherapplicablecompliance documents,worksheets,calculatons, plans and speclflcaticins submittedto the enforcementagency for approvalwith this buildirg permit application. 5. 1 will ensure that a com pleted signed copy of this Certificate of Compliancesha 11 be made ava ila blewith the bui Idingpe rmit(s)issued for the building and made available to the enforcementagencyforallapplicableinspections.IunderstandthatacompletedsignedcopyofthisCertificateofComplian eisrequiredtobeincludedwiththedocumentationthe Responsible Designer Name: GARY WANG Responsible Designer Signature: Company : GARY WANG & ASSOCIATES, INC. Date signed: 07-30-14 Address: 1255 CORPORATE CENTER pR, PH 8 cense: C-32569 City/State/Zip: MONTEREY PARK, CA 91754 Phone: 62S-285-6898 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards. 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA LINE -VOLTAGE TRACK LIGHTING WORKSHEET CEC-NRCC-LTI.05-E (Revised 06113) CALIFORNIA ENERGY COMMISSION: CERTIFICATE 0ECCMPLIANCE NRCC-LTI-05-E Indoor Lighting Line Voltage Track Lighting Worksheet Pae 1 of 2 Project Nam e: WABA GRILL Date Prepared: 07-30-14 There are four different methods available for determining how many watts of line voltage track or line voltage busway has been installed. One or more methods may be used to determine how many watts of line voltage track or line voltage buswa y has been installed. Use this worksheet to separately calculate the input wattage for each system. Separately enter each row of this worksheet into the Luminaire Schedule in section C of NRCC LTI 01 E Method 1 is the only option available for determining wattage for track or busway rated for more than 20 amperes METHOD 1 VOLT AMPERE (VA) RATING OF THE BRANCH CIRCUIT(S) A B BRANCH CIRCUIT NAME OR ID VOLT AMPERE (VA) RATING OF THE BRANCH CIRCUIT F Track or Name # Linear Feet of Track (WOLF) B x W TOTALRATEDWATTAGEOF ALL LUMINAIRES METHOD 2 USE THE HIGHER OF 45 WATTS PER LINEAR FOOT OF TRACK OR TOTAL RATED WATTAGE OF ALL LUMINAIRES A B C D E F Track or Name # Linear Feet of Track (WOLF) B x W TOTALRATEDWATTAGEOF ALL LUMINAIRES LARGER OF Dor E Largerof D or E F 45 12.5 100 120 120 1 45 12.5 500 360 500 45 12.5 METHOD 3 USE THE HIGHER OF: 12.5 WATTS /LINEAR FOOT OF TRACK OR VA RATING OF INTEGRAL CURRENT LIMITER Only integral current limiters which are certified to the Energy Commission shall be recognized by the Standards. This method shall not be reco nized if an Installation Certificate is not submitted. A B C D E F Track or Name # Linear Feet of Track (WAF) B x C W VA Rating of Integral Current Limiter Largerof D or E F 8 12.5 100 120 120 1 40 12.5 500 360 500 12.5 METHOD 4 DEDICATED TRACK LIGHTING SUPPLIMENTARY OVERCURRENT PROTECTION PANEL This method shall not be recognized if an Installation Certificate is not submitted. This method shall be used only for line voltage track lighting, and shall not be recognized for any other lighting systems. If any other lighting systems or devices are installed the suonTem entary overcurrent protection Danel shall not be recognized for compliance with the Standards A B C D NAME OR ID Voltage of the Branch Circuit Sum of the Ampere Rating of all Devices installed in the Panel Wattage = Sum of the Ampere Rating s of all of the Devices Times The Branch Circuit Voltage B xC Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA LINE -VOLTAGE TRACK LIGHTING WORKSHEET $' " CEC-NRCC-LTI-05-E Revised 06/13 ' CALIFORNIA ENERGY COMMISSION s CERTIFICATE OF COMPLIANCE NRCC J105E Indoor Lighting Line Voltage Track Lighting Workshee t (Paget Of 2) ProjectNam e: nABA GRILL Date Prepared: 07-30-14 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certiN that this Certificate of Compliance documentation is accurate and complete, Documentati on Author Name: GARY WANG Documentation Author Signature: , Company: GARY WANG & ASSOCIATES. INC. Signature Date: 07_30-14 Address: 1255 CORPORATE CENTER DR. PH 8 CEA/HERS Certification Identification (if applicable): City/State/Zip: MONTEREY PARK, CA 91754 Phone: 626-288-8898 RESPONSIBLQERSON'SDECLARATIW STATEMENT I certify thefolloNing underpenalty of perjury, underthelawsoftheStateof California: 1. The information provided on this Certificate -of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certifica to of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understa d that a completed signed copy of 'to this Certificate of Compliance is re uired be included with the documentation the builder Provides to the buildi ne owner at occupancy. Responsible Designer Name: GARY WMG Responsible Designer Signature: Company : GARY WANG & ASSOCIATES. INC. Date Signed: 07-30-14 Address: 1258 CORPORATE CENTER DR. PH 8 License: C-32589 City/State/zip: MONTEREY PARK, CA 91754 Phone: 628_288_6898 _ r Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Nonresidential Compliance June 2013 0Ffl ?4PWIZDI4__ IofZ- PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 1 of 3) PERFAC Project Name Date Waba Grill - @ The Pavilion at La Quints 8/8/2014 Project Address Climate Zone Total Cond. Floor Area Addition Floor Area 79-024 State Highway 111, Unit 103 La Quinta CA Climate Zone 15 1,368 1,368 GENERAL INFORMATION Building Type: m Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel Guest Room ❑ Relocatable - indicate ❑ specific climate zone ❑ all climates Phase of Construction: ❑ New Construction ❑ Addition ❑ Alteration STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation author hereby certifies that the documentation is accurate and complete. �. Documentation Author Name Art Ab/ay Signature Company ACA Consulting Date 818/2014 Address 1645 Amberwood Drive #26 Phone 6262433211 City/State/Zip South Pasadena, CA 91030 The Principal Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the energy efficiency requirements contained in sections 110.0, 116.0 through 118.0, and 140.0 through 149.0 of Title 24, Part 6. Please check one: ENV. LTG. MECH. I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to ❑ ❑ ❑ sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section ❑ ❑ ❑ 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document ❑ ❑ ❑ because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. Principal Envelope Designer Name Signature Company Envelope Compliance Not /n The Scope Of This Document Date Address License # City/State/Zip Phone Principal Mechanical Design r Name BUILDING &SAFETY L, R��aat e Gary Wang Company Gary Wang & Associates, Inc. Date ✓ Address 1255 Corporate Center D ve, Ph CONSTRUC License# City/State/Zip Monterey park, CA 91754 Phone 6262886898 Principal Lighting Designer Name Signature Company Lighting Compliance Not In The Scope Of This Submittal Date Address License # City/State/Zip Phone INSTRUCTIONS TO APPLICANT COMPLIANCE & WORKSHEETS (check box if worksheets are included) ❑ ENV -01 Certificate of Compliance. Required on plans. m MCH -01 Certificate of Compliance. Required on plans. ❑ LTI-01 Certificate of Compliance. Required on plans. m MCH -02 HVAC Air/Water Side Requirements. ❑ LTI-02 Lighting Controls Credit Worksheet. m MCH -03 Mechanical Ventilation and Reheat. ❑ LTI-03 Indoor Lighting Power Allowance. m MCH -07 Mechanical Equipment Details. Ener Pro 6.2 by EnergySoft User Number: 9621 Run Code: 2014-08-08719:41:40 ID: Pae 1 of 9 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 2 of 3) PERF -1C Project Name Date Waba Grill - The Pavilion at La Quinta 8/8/2014 ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed Compliance Energy Component Design Design Margin Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process Process Lighting TOTALS 0.69 3.46 -2.77 341.67 420.04 -78.36 224.13 153.01 71.12 0.00 0.00 0.00 0.00 0.00 0.00 116.04 105.70 10.34 148.47 148.47 0.00 117.20 117.20 0.00 48.34 48.34 0.00 0.00 0.00 0.00 996.53 996.22 0.32 Heating Cooling Fans Heat Rej Pumps DHW Lighting Receptacle Process Process Ltg Percent better than Standard 0.0% 0.0 % excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (E) Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Natural Gas Available On Site (S) sqft. sqft. sqft. (N) 0 deg 1,368 1 95 2 1,368 4 Yes Front Elevation Left Elevation Rear Elevation Right Elevation Total Roof Orientation Gross Area (N) 286 (E) 528 (S) 60 (vt7 0 874 1,405 sqft. sqft. sqft. sqft. sqft. sqft. G127ina Area t A I k'tUQ /-"►J 'iu T I ItJ I Standardi Y I 3:iAa 8 Pro osedUEl Prescriptive Lighting Power Density 1.321 _//Sgft 1.321 W wui 'i 3UHT?.Y103 H01 Remarks: 1 .:X 148 114 0 0 262 0 sqft. sqft. sqft. sqft. sqft. sqft. Gla7ino Rntin 51.7% 21.6 0.0 0.0% 30.0 0.0 Prescriptive Values for Comparison only. See LTI-01 for allowed LPD. I EnergyPro 6.2 by EnergySoft User Number., 9621 RunCode: 2014-08-08719:41:40 /D: Page 2 of 9 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 3 of 3) PERF -1 C Project Name Waba Grill - @ The Pavilion at La Quinta Date 8/8/2014 ZONE INFORMATION System Name Zone Name Floor Inst. Area LPD Occupancy Type s ft. LW/S91 Ctrl. Allowed LPD Credits Area Tailored (W/S2 (W/Sol (W/Sol(W/So Proc. Loads Existing HP -1 Dining Zone Dining 640 '1.100 New AC -1 Support Zone CorridoNRestroom/Support 61 "0.600 Kitchen Zone Kitchen, Food Preparation 667 "1.600 0.821 Unconditioned Zone Electrical, Mechanical Room 95 "0.700 Notes: 1. See LTI-01 2. See LTI-02 3. See LTI-03 4. See LTI-04 items marked with asterisk, see LTI-01 b others b others Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justifications, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp EnergyPro 6.2 by EnergySoft User Number.' 9621 Run Code: 2014-08-08T19:41.40 /D: Page 3 of 9 STATE OF CALIFORNIA MECHANICAL SYSTEMS MIN) CEC-NRCC-MCH-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSIOI` '4 CERTIFICATE OF COMPLIANCE NRCC-MCH-01-E Mechanical Systems (Page 1 of 4) Project Name: Waba Grill - @ The Pavilion at La Quinta Date Prepared: $/$/2014 MECHANICAL COMPLIANCE FORMS St WORKSHEETS (check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. YES " NO Form/Worksheet # Title IZI ❑ NRCC-MCH-01E (Part 1 of 3) Certificate of Compliance, Declaration. Required on plans for all submittals. El ❑ NRCC-MCH-01E (Part 2 of 3) Certificate of Compliance, Required Acceptance Tests (MCH -02A to 11A). Required on plans for all submittals. Z ❑ NRCC-MCH-01E (Part 3 of 3) Certificate of Compliance, Required Acceptance Tests (MCH -12A to 18A). Required on plans where applicable. ❑ 0 NRCC-MCH-02E (Part 1 of 2) Mechanical Dry Equipment Summary is required for all submittals with Central Air Systems. It is optional on plans. ❑ ❑ NRCC-MCH-02E (Part 2 of 2) Mechanical Wet Equipment Summary is required for all submittals with chilled water, hot water or condenser water systems. It is optional on plans. ❑ 10 INRCC-MCH-03E Mechanical Ventilation and Reheat is required for all submittals with multiple zone heating and cooling systems. It is optional on plans. MECHANICAL HVAC ACCEPTANCE FORMS (check box for required forms) Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for HVAC systems. The designer is required to check the applicable boxes for all acceptance tests that apply and list all equipment that requires an acceptance test. All equipment of the same type that requires a test, list the equipment description and the number of systems. Installing Contractor: The contractor who installed the equipment is responsible to either conduct the acceptance test them self or have a qualified entity run the test for them. If more than one person has responsibility for the acceptance testing, each person shall sign and submit the Certificate of Acceptance applicable to the portion of the construction or installation for which they are responsible. Enforcement Agency: Plancheck — The NRCC-MCH-01-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. Inspector - Before occupancy permit is granted all newly installed process systems must be tested to ensure proper operations. Test Description MCH -02A MCH -03A MCH -04A MCH -05A MCH -06A MCH -07A MCH -08A MCH -09A MCH -10A MCH -11A Equipment # of Outdoor Single Zone Air Economizer Demand Supply Fan Valve Leakage Supply Water Hydronic Automatic Requiring Testing units Ventilation Unitary Distribution Controls Control VAV Test Temp. Reset System Demand Shed or Verification Ducts Ventilation Variable Flow Control (DCV) Control Trane YHC0371 1 d ® ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA MECHANICAL SYSTEMS CEC-NRCC-MCH-01-E Revised 06/13 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-01-E Mechanical Systems - (Page 2 of 4) Project Name: Waba Grill - @ The Pavilion at La Quinta Date Prepared: 8/8/2014 MECHANICAL HVAC ACCEPTANCE FORMS (check box for required forms) Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for HVAC systems. The designer is required to check the applicable boxes for all acceptance tests that apply and list all equipment that requires on acceptance test. All equipment of the some type that requires a test, list the equipment description and the number of systems. Installing Contractor: The contractor who installed the equipment is responsible to either conduct the acceptance test them self or have a qualified entity run the test for them. If more than one person has responsibility for the acceptance testing, each person shall sign and submit the Certificate of Acceptance applicable to the portion of the construction or installation for which they are responsible. The following tests require a Enforcement Agency: Ploncheck — The NRCC-MCH-01-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. Inspector - Before occupancy permit is granted all newly installed process systems must be tested to ensure proper operations. Test Description MCH -12A MCH -13A MCH -14A MCH -15A MCH -16A MCH -17A MCH -18A Equipment # of Fault Detection & Automatic Fault Distributed Energy Thermal Energy Supply Air Condenser Water ECMS Requiring Testing units Diagnostics for DX Detection & Storage DX AC Storage (TES) Temperature Reset Reset Controls or Verification Units Diagnostics for Air & Systems Systems Controls Zone Trane YHC037 1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA HVAC SYSTEM REQUIREMENTSfPZBQ, CEC-NRCC-MCH-02-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-02-E HVAC Dry System Requirements (Page 1 of 3) Project Name: Waba Grill - @ The Pavillon at La Qulnta nate Prepared: $/$/2014 Equipment Tags and System Description Existing HP -1 New AC -1 MANDATORY MEASURES Heating Equipment Efficiency3 Cooling Equipment Efficiency3 HVAC or Heat Pump Thermostats Furnace Standby Loss Control Low leakage AHUs Ventilation Demand Control Ventilations Occupant Sensor Ventilation Contro16 Shutoff and Reset Controls' Outdoor Air and Exhaust Damper Control Isolation Zones Automatic Demand Shed Controls Economizer FDD Duct Insulation PRESCRIPTIVE MEASURES T-24 Sections Reference to the Requirements in the Contract Documents2 110.1 or 110.2(a) 110.1 or 110.2(a) 110.2(b), 110.2(c) 110.2(d) 110.2(f) 120.1(b) 120.1(c)4 120.1(c)5, 120.2(e)3 120.2(e) 120.2(f) 120.2(g) 120.2(h) 120.2(i) 120.4 Equipment is sized in conformance with 140.4(a & b) 140.4(a&b) Supply Fan Pressure Control 140.4(c) Simultaneous Heat/Cools 140.4(d) Economizer 140.4(e) Heat and Cool Air Supply Reset 140.4(f) Electric Resistance Heating9 140.4(g) Duct Leakage Sealing and Testing.10 140.4(1) Notes: 1. Provide equipment tags (e.g. AHU 1 to 10) and system description (e.g. Single Duct VAV reheat) as appropriate. Multiple units with common requirements can be grouped together. 2. Provide references to plans (i.e. Drawing Sheet Numbers) and/or specifications (including Section name/number and relevant paragraphs) where each requirement is specified. Enter "N/A" if the requirement is not applicable to this system. 3. The referenced plans and specifications must include all of the following information: equipment tag, equipment nominal capacity, Title 24 minimum efficiency requirements, and actual rated equipment efficiencies. Where multiple efficiency requirements are applicable (e.g. full- and part -load) include all. Where appliance standards apply (110.1), identify where equipment is required to be listed per Title 201601 et seq. 4. Identify where the ventilation requirements are documented for each central HVAC system. Include references to both central unit schedules and sequences of operation. If one or more space is naturally ventilated identify where this is documented in the plans and specifications. Multiple zone central air systems must also provide a MCH -03-E form. 5. If one or more space has demand controlled ventilation identify where it is specified including the sensor specifications and the sequence of operation. 6. If one or more space has occupant sensor ventilation control identify where it is specified including the sensor specifications and the sequence of operation 7. If the system is DDC identify the sequences for the system start/stop, optimal start, setback (if required) and setup (if required). For all systems identify the specification for the thermostats and time clocks (if applicable). 8. Identify where the heating, cooling and deadband airflows are scheduled for this system. Include a reference to the specification of the zone controls. Provide a MCH -03-E form. 9. Enter N/A if there is no electric heating. If the system has electric heating indicate which exception to 140.4(g) applies. 10. If duct leakage sealing and testing is required, a MCH -04-A form must be submitted. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA MECHANICAL VENTILATION AND REHEAT num CEC-NRCC-MCH-03-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-03-E Mechanical Ventilation & Reheat (Page 1 of 2) Project Name: Waba Grill - @ The Pavilion at La Quinta Date Prepared: 8/8/2014 ACTUAL DESIGN INFO (FROM EQUIPMENT SCHEDULES, ETC) AREA BASIS OCCUPANCY BASIS MINIMUM VAV Reheated Primary Air CFM VAV Deadband Primary Air CFM A B C D E F G H I 1 K L M N O P Q R S T N < O < z O< X in C, OO 0= 2� T�z 3 D` n < D O T O_ D ooz m n oa 3 1 =O D N Z ai �nG1 D n a i{ n z 2 m `o n D p ,^ rz 3 rp r Viz n O z spg D z O z r 3 m D D T 3 Z n 3 m W D z C 3 v o m n m n m Z z T a� z m 2 W o c 9 X D m C30;n0 3_ p< A�� _ n0 3 o z in z0 � y r?o0 < O 3 0 O.n A n no ° 2 L1 n 3 D 3 3 p3c D 3 O x o= 3 a � 0 3 � _ y N 0 T z O O � 0 n n z D iu Z a m T o K n Oo ? z O v Dining 640 0.50 320 42.9 7.5 320 320 Y Total 320 SUPPC 61 0.15 9 0.6 15.0 9 9 Y Kitche 667 0.15 100 1 3.3 30.0 100 100 Y Total 109 Yellow shaded cells require user input. Remaining cells are protected and automatic B. The largest amount of primary air supplied by the terminal unit when it's operating in the cooling mode. C. The smallest amount of primary air supplied by the terminal unit in the deadband mode. D. The largest amount of primary air supplied by the terminal unit when it's operating in the heating mode. E. A terminal unit can be controlled with DDC controls, or non -DDC controls. Each control category has different reheat limitations in code. F. Transfer Air must be provided where Required Ventilation Airflow (Column M) is greater than the Design Primary Deadband Airflow (Column C). CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 NRCC-MCH-07-E Project Name Waba Grill - @ The Pavilion at La Quinta Date 8/8/2014 CHILLER AND TOWER SUMMARY PUMPS Equipment Name Type Qty. Efficiency Tons Pump Qty. GPM BHP Control DHW / BOILER SUMMARY System Name Type Distribution Qt7y. Rated Input Vol. (Gals). Energy Factor Standby Loss Tank Ext or RE or Pilot R -Value Status Bradford -White Corp. UPDX65S5! Small Gas Standard 1 55,000 65 0.60 n/a n/a New MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water Pump Hot Water Piping Length ft Control Qty- HP Type In Plenum Outside Buried I Add 'A" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING System Name Type Qty. Output Aux. kW Efficiency Output Efficiency Status CARRIER 50HJQ006 Packaged DX 1 55,000 0.0 7.70 HSPF 58,000 13.0 SEER / 11.0 EER Existing Trane YHC037E3 - WABA GRILL LA QUIN Packaged DX 1 48,000 0.0 80% AFUE 34,460 17.5 SEER / 13.0 EER New CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN System Name Fan Type Economizer Type CFM BHP CFM BHP CARRIER 50HJQ006 Constant Volume No Economizer 2,000 1.16 none Trane YHC037E3 - WABA GRILL LA QUINTA Constant Volume No Economizer 1,200 0.30 none EnergyPro 6.2 by EnergySoft User Number: 9621 RunCode: 2014-08-08T19:41:40 ID: Page 8 of 9 P STATE OF CALIFORNIA WATER HEATING SYSTEM GENERAL INFORMATION CERTIFICATE OF COMPLIANCE NRCC-PLB-01-E Water Heating System General Information (Page 1 of 3) Project Name: Waba Gall - (o-)- The Pavilion at La Quetta Date Prepared: 8/8/2014 A. GENERAL INFORMATION/SYSTEM INFORMATION 1. Water Heater System Name: Bradford -White Corp. UPDX65S55FR*N 2. Water Heater System Configuration: Non -Central 3. Water Heater System Type: 5. Required Minimum Efficiency: 4. Building Type: 0.000 . 5. Total Number of Water Heaters in Systems: 1 6. Central DHW Distribution Type:. n/a 7. -Dwelling Unit DHW Distribution Type: Standard The responsible person's signature on this Certificate of Installation indicates the system identified on this Certificate has complied with all applicable requirements specified in this Table. B. WATER HEATER INFORMATION Each water heater type requires a separate form. 1. Water Heater Type: Small Gas 2. Fuel Type Gas Fired 3. Number of Identical Water Heaters: 1+ 4. Efficiency: 0.60 5. Required Minimum Efficiency: 0.60 6. 1 Standby Total or Standby: 0.000 7. Rated Input 55,000 8: Pilot Energy: 9. Water Heater Tank Storage Volume: 65 10. Exterior Insulation On Water Heater: 0 11. Volume of Supplemental Storage: 12. Internal Insulation on Supplemental Storage: 13. Exterior Insulation on Supplemental Storage: The responsible person's signature on this Certificate of Installation indicates the system identified on this Certificate has complied with all applicable requirements specified in this Table. CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance D June 2013