Loading...
05-4772 (RC)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 05- 00.0 1717_ Property Address: 80440 HIDEAWAY CLUB CT APN: 772-410-998-30 -32453 - Application description: REMODEL - COMMERCIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 45000 c&.tvI 4 4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: A B LicenseNo.: 764528 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5•, Business and Professions Code: Any city or county that requires a'permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State -License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1/� 1 I, as owner. of the property, am exclusively contracting with licensed contractors to construct the project (Sec. C 7044, usiness and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (�1 I am exempt under Sec. , B.&P.C. for this reason CONSTRUCTIM LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097. Civ. C.). Lender's Name: Lender's'Address: r LQPERA11T Owner: ND LA-QUINTA PARTNERS 375 N FRONT ST STE 200 COLUMBUS, OH 43215 N Contractor: LINTHICUM CONSTRUCTORS, INi 20789 NORTH PIMA ROAD STE 250 SCOTTSDALE, AZ 85255 (480)515-1700 Lic. No.: 764528 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/30/05 U�4 n 12005 t v nF LA►QUINTA --------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and, will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier SCF OF ARIZONA Policy Number 3150042 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section / 3700 of th�,Wbor Code, I sha11 f�rtkyvithypmply with_h9se provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. ' 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is'correct. I agree to comply with'all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of�ftis countyenter upon above-mentio roperty rinsp- io purposes. D 'a•� igatVr -ri re (Ap ' t o (A i V . it Application Number . . . . 05-00004772 Permit MECHANICAL Additional desc Permit Fee .00 Plan Check Fee .00 Issue Date . . . . 11/30/05 Valuation 0 Expiration Date . . 5/30/06 -------------------------------=--------------- Special Notes and Comments -----------------------=----- CLUBHOUSE MAIN LEVEL HVAC'REVISIONS WHILE UNDER CONSTRUCTION.supplement to issued permit.04-5331. 2001 CODES. TYPE V-1HR CONSTRUCTION. ------------=------------------------=----------=--------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 24.83 HOURLY PLAN CHECK 87.50 Fee summary Charged Paid ---------- Credited Due' ----------------- Permit Fee Total ---------- .00 ---------- .00 ---------- .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 112.33 .00 .00 112.33 Grand Total 112.33 .00 .00 112.33 LQPERA11T Bt� City of LaQ uinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:O- p �� AFN� �3 &UZ4 Owner's Name: J�fAp, X42 A. P. Number: Address: g0 r4Alil% Legal Description: bL)8 C.l)S�F, Contractor: kl wt Y 1 GU Wl 6 O2-A•� City, ST, Zip: Telephone: �O oZ 75 -7 '9,l Address: -20?N P,vq AD S , 2,S9 Project Description: $ city, ST, Zip: ,6-� S �� A Z 5 2 55 Telephone: �i0- I5 -I -)00- 9 w3� State Lic. # : City Lic. #: Arch., Engr., Designer: -fir 5 = -� t0 K)A L G 1.„a �S Address: vs.(, -F- SF-7=rS P wA Op City, ST, Zip: S Telephone: 60 - iK5- (8 T Construction Type: Occupancy: State Lic. #: .� Name of Contact Person: L)2 2�� Project type (circle one) New Add'n Alter Repair Demo . Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: '&0-97S- % a Estimated Value of Project: 1! - APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets 3 Plan Check submitted �� ,p % Item Amount Structural Calcs.. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance , Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical • Gradin plan Grading P 2" Review, ready for correction /issue t ?7 p Electrical Subcontactor List Called Contact Person It fl Plumbing Grant Decd Plans picked up j- S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Jrd Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue • 0- School Fees Total Permit Fees 11�- ^ ! lir/ 42 t0N — /ve c✓ �• ,` ' OCT 2 4 2005 'Memo. To: CITY OF LA QUINTA BUILDING DEPARTMENT From: DEXTER BARR - POLAR BARR AIR CONDITIONING, INC. Date: October 13, 2005 Re: HIDEAWAY COUNTRY CLUB CLUBHOUSE - LA QUINTA, CA. UPPER LEVEL HVAC SYSTEM AND EQUIPMENT CHANGES THE REVISED TITLE 24 CALCULATIONS PREVIOUSLY SUBMITTED WITH THE LOWER LEVEL MECHANICAL CHANGES REFLECT ALL OF THE MECHANICAL CHANGES FOR BOTH THE UPPER AND LOWER LEVEL (WE HAVE ALSO INCLUDED COPIES WITH THIS SUBMITTAL). IT IS ASSUMED THE LOWER LEVEL PLAN CHECK IS COMPLETED AND THAT AREA IS NOW MOVING FORWARD TOWARD COMPLETION. THIS CHANGE REQUEST IS FOR THE UPPER LEVEL ONLY EXCEPT FOR ONE AREA. THE HVAC SYSTEM SERVING THE "BACK OF HOUSE" ON THE . LOWER LEVEL (HP -1), IS TOO SMALL. ON THE ORIGINAL MECHANICAL PLAN, IT IS A 7 % TON UNIT. THE REVISED TITLE 24'S ARE CALCULATED FOR 2 - 7'/z TON SYSTEMS BUT THE OWNER HAS REQUESTED ONLY 1- 5 TON SYSTEM BE ADDED. THE AREA IS NOW SERVED BY HP -1A (7 % TON) AND HP -1 B (5 TON). HP -1 B AND ALL OF ITS AIR DISTRIBUTION ARE COMPLETELY ABOVE T -BAR CEILINGS AND FULLY ACCESSIBLE FOR INSTALLATION AND INSPECTION (INCLUDING THE REFRIGERATION LINES). ALL OTHER LOWER LEVEL SYSTEMS REMAIN AS SUBMITTED IN THE PREVIOUS PLAN CHECK PACKAGE. (NOTE: DELTA 8 BUBBLE AROUND . HPA B SYSTEM. ON LOWER LEVEL) THE UPPER LEVEL CHANGES INCLUDE ADDITIONAL SYSTEMS AND CHANGES IN TONNAGE ON EXISTING SYSTEMS. THE TITLE 24 0 Page 1 CALCULATIONS REFLECT THE NEW NUMBERING SCHEDULE ON THE PLANS. THE SYSTEMS ON THE UPPER LEVELS ARE AS FOLLOWS: HP 10 SERVES THE WEST SIDE MEN'S LOCKER ROOM AND WAS ORIGINALLY A 10 TON UNIT. IT IS NOW A 7'/2 TON UNIT AS REFLECTED IN THE TITLE 24 CALCULATIONS. HP 11 SERVES THE WEST CORRIDOR, LOBBY, RESTROOM, DINING ROOM AREA. IT WAS DETERMINED TO BE UNDERSIZED AND CLEARED FOR AN ADDITIONAL SYSTEM BY THE TITLE 24 CALCULATIONS. THE OWNER DECIDED TO ADD A 5 TON SYSTEM SO UNIT 11 (7'/2 TON) AND UNIT 11A (5 TON) NOW SERVE THIS AREA. HP12 SERVES THE MEN'S LOUNGE. IT WAS DETERMINED TO BE UNDERSIZED AND WAS CLEARED FOR 2 - 7 % TON SYSTEMS BY THE TITLE 24 CALCULATIONS. IT ORIGINALLY ONLY HAD 1 - 7'/z TON SYSTEM. THE OWNER DECIDED TO ADD 1 - 5 TON SYSTEM SO THIS AREA IS NOW SERVED BY HP -12A (7'/2 TON) AND HP -12B (5 TON) HP13 SERVES THE EAST SIDE OF THE MEN'S LOCKER ROOM AND IS STILL A 7 % TON UNIT. HP14 SERVES THE MAIN BAR AREA AND IS NOW A 10 TON UNIT. IT WAS. ORIGINALLY A 7 % TON SYSTEM. HP15 ORIGINALLY WAS A 10 TON UNIT AND SERVED THE MAIN DINING ROOM AREA AND 2 PRIVATE DINING ROOMS. IT WAS DETERMINED TO BE UNDERSIZED AND WAS CLEARED BY THE TITLE 24 CALCULATIONS FOR AN ADDITIONAL 7'/2 TON SYSTEM. THE OWNER HAS CHOSEN TO INSTALL AN ADDITIONAL 5 TON SYSTEM. HP15A IS A NEW ADDITIONAL 5 TON SYSTEM. 'HP16 SERVES THE KITCHEN AND IS STILL A 12 % TON ROOF TOP PACKAGED UNIT. AC 2 AND 3 ARE STILL "DECTRON" DEHUMIDIFICATION UNITS SERVING THE MEN'S SPA/JACUZZI AREA. PLEASE FEEL FREE TO CONTACT ME ANY TIME FOR EXPLANATIONS OR CLARIFICATIONS. 0 Page 2