Loading...
06-0331 (OFC) Title 24.. 6- � 7 TITLE 24 REPORT Title 24 Report for: PETCO ANIMAL SUPPLIES, INC. 111 LA QUINTA CENTER LA QUINTA, CA 92253 Project Designer: CARL COX, AIA 81-557 DR. CARREON BLVD. I N D 10, CA- 92201 (760) 347-4007 Report. Prepared By: JOHN JOLLY C+J Technical Solutions and Services 404 Laspino Lane Diamond Bar, CA 91765FBU OF LA QUINTA (909) 896-3631 NG & SAFETY DEPT.. PPROVED FOR CONSTRUCTION DA ✓>c Z gy ol L % Job Number: C05083 Date: fir. 4/3%2006 The EnergyPro computer program has been used to perform the calculations summarized In this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number: C05083 User Number 5950 � ! y. A .. � e } y'} ' ERFORMANCE CERTIFICATE OF ROJECT NAME PETCO ANIMAL SUPPLIES, INC. ROJECT ADDRESS CIAINs111 LA QUINTA CENTER LA QUINTA w, n MPLIANCE Part 1 of 3 DATE PERF -1 4/3/2006 c14YCLVF•t CARL COX, AIA TELEPHONE �uldmg erm` f#r K a r AENTATION AUTHOR (760) 347-4007 � t C+J Technical Solutions andTELEPHONE y1�D`atQ F t:: Services 909 896-3631 eC`ea Y ;RAL INFORMATION IF PLANS BUILDING ONDITIONED FLOOR AREA 15 249 CLIMATE ZONE sq.Ft. 15 VG TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION ❑ EXISTING + ADDITION/ALTERATION Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the ornla Code of Regulations. This certificate applies only to a Building using the performance compliance approach. documentation preparer hereby certifies that the documentation Is accurate and complete. I III�C hITAT1A�, w, T.ai._ The Principal Designer hereby certifys that the proposed b ' ding desig represented in this set of constructi ; on documents is onsistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. 'The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. ❑ ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ ❑ ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ ❑ ❑ ,3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual,) Indicate location on plans of Note Block for Mandatory Measures Required For V-1 CIPAL ENVELOPE DESMmFR . meRAr .. Indicate location on plans of Note Block for Mandatory Measures Lightinc Required.Forms This S ICIPAL LIGHTING DESIGNER • NAME S!GNATUR€ ;�IANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms IVIECH- CIPAL MECHANICAL DESIGNER - NAME SIGNA�UR C + J TECHNICAL SOLUTIONS & I rl n,DZ/n CWffaKm Compliance Not In The Scope Of NO. I DATE -2, MECH-3, MEC ILIC. NO. I DAl Vj nun irnztauon lime* 000-3/0617,S2:08 Run Codes 1144110728 4.1 by Energysoft User Number, 5950 Job Number: C05083 Page:3 of 16 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 ---PERF. NAME ET ENERGY COMPONENT Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process Standard Design ° TOTALS: 633.54 Percent better than Standard: z Proposed Design Compliance Margin 0.56 50.12 17.48 0.00 0.00 0.00 0.00 0.00 0.00 565.38 68.16 10.8% ( 10.8% DATE Building Orientation N o deg Conditioned Floor Area 15,249 sgft. Number of Stories 1 Unconditioned Floor Area 0 sqh. Number of Systems 5 Conditioned Footprint Area 15,249 sgft. Number of Zones 2 Fuel Type Natural Gas Orlentatlon Gross Area Glazing Area Front Elevation N 1,800 sgft. 0 Left Elevation E 2,946 sgft. 0 Rear Elevation s 1,800 sqh. 505 Right Elevation W) 837 sgft. 0 Glazlnp sgft. sgft. sgft. sqh. Ratio 0.0% 0.0% 28.1% 0.0% Total 7,383 sqh. 505 sgft. 6.8% Roof 15,249 sqft. L---� sgft Standard Proposed Lighting Power Density 1.647 W/sgft. 1.647 W/sgft. Prescriptive Env. Heat Loss 3,835 Btu/h 2,396 Btu/h Prescriptive Env. Heat Gain 252,976 Btu/h-F 184,808 13tu/h-F Remarks: 4.1 by EnergySoft User Number: 596o Job Number: C05083 • w Page:4 of 16 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PFR;'_i and ocumentation, and special verlflcatlon-.,_to _ _b__e. u_sed_._...wit.,,,,h thet—h'e-- . ""' apou,nou 111 11113 Cr1eCK118[. r nese items require special written justification performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Lennox LGA1201-1"' Includes Demand Control Ventilation per Standards Section 121. The HVAC System "Lennox LGA060H+" includes an Economizer. This system has a cooling output < 75,000 Btuh or a sup2ly cfm < 2500. The HVAC System "Lennox LGA0601-1"" Includes Demand Control Ventilation per Standards Section 121. C. The exceptional features listed In this erforrnance approach ppappli application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stomn r,ur rninaiton tune• 04/03/06 17.32.08 Run Code• 1144110728 4.1 by EnergySoft User Number: 5950 Job Number: C05083 . Paae:5 of 16 CERTIFICATE OF COMPLIANCE =E=NV-1 PROJECT NAME PETCO ANIMAL SUPPLIES, INC. DATE �PA0t1F Al iR�errc 4/3/2006 t—j— --, u—iii i cunsoucuon ana In the b Ilding manager's once after Construction Act. Cond. Location/ # T e Area U -Fac' SHGC2 Azm. Stat. Maging Type Comments 1 Window Rear S 505 1.280 116-A 0.67 116-B 180 New Sin le Metal Tinted RETAIL (1) U•factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manuel Appendix, NFRC LabelQd value. 2 SHOO Type: 116.8 Default Table Irani St—Inrda rrnr; r`rmo..d ni EXTERIOR SHADING # Exterior Shade Type 1 None Window Overhang Left Fin Right Fin SHGC Hgt. Wd. Len. H t. LEMAExt. Dist. Len. H t. Dist. Len. H t. 0.76 11.3 44.7 10.0 0.1 10.0 10.0 MINIMUM SKYLIGHIAREA FOR LA_RGEENCLMED SpACES ❑The proposed building contains an enclosed space with floor area greater than 26,000 sq,ft, a calling height greater than 16 feet and a LPD for general lighting of at least 0.6 W/ao.ft. If this box Is checked. ENV -d -r moat h. auen ...e k.. .. ..-'__ "_ ..__ _ _ ... _ .. _ EnergyPro 4.1 by EnergySoft User Number: 5950 Job Number: C05083 Page: B of 16 ICERTIFICATE OF COMPLIANCE MECH-I-C PROJECT NAME PETCO ANIMAL SUPPLIES INC. DATE Designer: 4/3/2006 This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section In the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (Le. the Installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space-condltloning system serving a building or space Is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance Information meet the requirements of Sectinn 10-lnafw ..A T101- nA n_— P4ATI'^ ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systerns both New Construction and Retrofit ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all Now systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all Now systems both New Construction and Retrofit. Units with economizers that are Installed at the factory and cenllled with the commisslon do not require equipment testing but do require construction Inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing 7'h1s test required if the unit serves 5,000If2 of space or less and 25% or more of the ducts are In nonconditioned or semioondldoned space like an a01c. New systems that meet the above requirements. Retrofit systems that meat the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls Installed on new or existing packaged syctoms must be tested. Q MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls Installed on now or existing systems must be tested MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new bollers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to now constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 etulhr. -Water-loop Heat Pump Controls Applies to all new waterloop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all now distribution pumps on now variable flow chilled, hydronlc heatpump or condenser water systems where the pumps motors are greater than 5 hp. 4.1 by EnergySoft User Number: 5950 Job Number: C05083 Peos:7 of 16 R SYSTEM REQUIREMENTS PROJECT NAME PETCO ANIMAL SUPPLIES, INC. ITEM OR SYSTEM TAG(S) Number of Systems W MANDATORY MEASURESSectiecti on . Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.219 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compllance3 Part 1 of 2 MECH-2-C DATE 4/3/2006 Reference on Plans or Specification 1 112(x) 80% AFUE 80% AFUE 112(a) 11.0 EER 13.0 SEER / 11.0 EER 112 b n/a n/a 112(c), 115(a) n/a n/a 121(b) Yes Yes 121 b 1054 cfm 102 cfm 121 c No. No 121 c Yes Yes 121(c), 122(e) Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heatirfg & Cooling Require 122(f) Auto Auto 122(g) n/a n/a 123 124 R-8.0 R-8.0 144 a & b n/a n/a 144 a & b 752,000 btuh 99,000 btuh 144 a & b n/a n/a 144 a & b 370,647 btuh 48,035 btuh 144 c Constant Volume Constant Volume 144 c 144 c Yes Yes 144 d No No 144 a Fixed Tem (Integrated) Fixed Tem Non -Into 144 f Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp 144 k No No 1: For each central and single zone air systems (or group of similar units)1111 In the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement Is not applicable, put "N/A" In the column. 2: Not required for hydronic heating and cooling, Either enter a value here or put In reference of plans and speclflcatons per footnote 1. 3: Enter Yes If System is: Constant Volume, Single Zone; Serves < 5,000 sgfh Has > 25% duct In unconditioned apace.. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. VOTES TO FIFI_ 19 _ Fnr R,ifirlinra n,&nsr#m n• i i-- ^-t.. I EnergyPro 4.1 by EnergySoft User Number: 5950 Job Number: C05083 Paga:8 of 16 0 V Ui Z O Q J Z W a L) 2 V W LU Q Z I- 0 U W O Q a Z Z O F— Uj a_ Z TraqMinAi FIE s 0) m wV LU c of m a jr 0 s N, J, W o > m CFM IICFM a °'Z.4 I c E n= O U i= > Qq. ft. _ 1. 1. > LU H a esign x m _� Supply r 3 m m d c Design ,Ea in -T o `o m — Vent. Air o o m o CFM ' G 3 m� o m .2 2 co READ V.Ar` n 0 000 z Max of v v a a � ro � x e (D or G) c' °' m v E o N Min CFM c3 m z a a.- m rn by Occupant � o a< E 5 -0 Q m (ExF) Fv ga a. E= aE E z v CFM m0-0 _ 8 u per S < z m� m a QZ oL. Person m ¢ = m U < t c `m' ` (3Number of W .m c- r 0 O People = o= o m m s m m s mm Min CFM e ° L m m- Q by Area v_ a m "" m (BxC) cD �mE s 2_ 0) Q CFM m g E �o Tcov per o 0 oma m N W Square Foot m m o E "m3 _� m < z a Condition Q o m ` m Area � =s4 m' m o >9 (SF) I m m m=m > cn xmm; � m m z m= t m j° `o EE ¢' m c 00< c� x m�(cj -a m¢ m>= _ _o ..m a mt _ m 3 m W0 V v Y o Z W o F `oG$LL•=ma i° m W } Q m o= w m - E 5 O v m c LU Z > m E arca Em U O =9m cE`m m=. v N a m a c E E O` Q m �a a X In cr J U Q N W U .- w` C w ¢ O Q W Z MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME PETCO ANIMAL SUPPLIES INC. °ATE 4/3/2006 HILLER AND TOWER SUMMARY Efficiency. Tons PUMPS Equipment Name Equipmentlypg Ot . Ott GPMFBHp MotorEff. °Effrive Control Energy Factor or RE StandbyANK Loss or Pilot INSUL. System Name System Type Distribution Typo Oty Rated Input Vol. Gals.) Condition Status Ext. R -Val. MULTI -FAMILY CENTRAL W6JEB HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Control # HP Type In Plenum Outside Buried Insulation ENTRAL SYSTEM RATINGS HEATING COOLING System Name System T _Output Aux. kW Eff. outDut Efficiency Condition Status Economizer Type Lennox LGA120H* Split DX 4 188,000 0,0 80%AFUE 128,000 11.0 EER New Fixed Temp (integrate( Lennox LGA060H* Split DX 1 99,000 0.0 80%AFUE 63,900 13.0 SEER / 11.0 EER New Fixed Temp (Non -Into CENTRAL SYSTEM FAN SUMMARY SUPPLY EARETURN FAN S stem Name Fan Type Motor Location CFM_ BHP Motor Eff. Drive Eff. CFM BHP Mlotor Eff. Drive Eff. Lennox LGA120H* Constant Volume Draw -Through 4,000 3.00 86.5% 100.0% none Lennox LGA060H' Constant Volume Draw -'Through 2,000 1.50 84.0% 100.0% none, Run Initiation Times 04/03/06 17&32@08 Run Codes 1144110728 EnergyPro 4,1 by EnergySoft User Number: 5950 Job Number: C05083 Page: 10 of 16 NVELOPE MANDATORY MEASURES ENV -MM ROJECT NAME PETCO ANIMAL SUPPLIES, INC. DAVE 4/3/2006 DESCRIPTION Designer Enforcement X§118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for Insulating material, Title 20, Chapter 4, Article 3. ® §118(c) All Insulating Materials shall be Installed In compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. ® § 117(a) All Exterior Joints and openings in the building that are observable sources of air • leakage shall be caulked, gasketed, weatherstrlpped or otherwise sealed. F § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors end fire doors). IAJ § 116(a)1 Manufactured Doors and Windows Installed shall have air Infiltration rates not exceeding those shown in Table Number I.E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. 0 §118(e) Demising Walls In Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have Insulation with an Installed R -value of no less than R-13 between framing members. tnergymo Uy EnergySoft UserNumber• User Job Number: C05083 Page 11 of 16 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME PETCO ANIMAL SUPPLIES. -INC. DATE DESCRIPTION Designer Enforcement a§131(d)1 For every floor, all Interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. X❑ 8131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override Is not to exceed 5,000 square feet. §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and Installed as directed by the manufacturer. §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed In the Directory. All Installed fixtures shall be certified. §132 ' Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. ❑ §131(a) Individual Room/Area Controls: Each room and area In this building Is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 900 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight In the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year Is included on plans. El §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.1 by EnergySofi User Number: 5950 Job Number: C05083 Page: 12 of 16 ECHANICAL MANDATORY MEASURES NAME PETCO ANIMAL SUPPLIES, INC. DESCRIPTION Equipment and Systems Efficiencies §111 Any appliance for which there is a California standard established In the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be Insulated In accordance with Standards Section 123. § 124 Air handling duct systems shall be Installed and Insulated in compliance with Controls Sections 601, 603 and 604 of the Uniform Mechanical Code. § 122(e) Each space conditioning system shall be Installed with one of the following: a§ 122(e)1 A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be Installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is Interrupted; or F§ 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of . the system. ® § 122(e)2 Each space conditioning system shall be Installed With controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpolnt. 0 § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with Isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off Independently of other Isolation areas; and shall be controlled by a time control device as described above. I-, VNI § 122(a&b) Each space conditioning system shall be controlled by an Individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. § •i22(c) Thermostats shall have numeric setpolnts In degrees Fahrenheit (F) and adjustable setpolnt stops accessible only to authorized personnel. ❑ §112(b) Heat pumps shall be Installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. Part 1 of 2 MECH-MMI DATE Designer JEnforcement I EnergyPro By EnergySoft User Number: User Job Number: C05083 PaQe:13 of 16 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-AI _m_ NAME PETCO_ANIMAL SUPPLIES, INC. DATE 4/3/2006 —Description Designer Enforcement Ventilation X§ 121(a) Controls shall be provided toallow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 122(f) Gravity or automatic dampers Interlocked and closed on fan shutdown shall be provided on the outside air Intakes and discharges of all space conditioning and exhaust systems. X❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings to the outside, except for combustion air openings. IX -1 ' § 121(f)1 Air Balancing: The system shall be balanced In accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or El § 121(f)2 outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certlfled by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of:outside air on a continuous basis and displaying that quantity an a readily accessible display divice; or § 121(f)4 Another method approved by the Commission. Service Water Beating Systems ❑ § 113(b)2 If a circulating hot water system Is Installed, It shall have a control capable of automatically turning off the circulating pump(s) when hot water Is not required. F] § 113(b)3B :Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. § 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0'S. gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro By EnergySoft User Number: User Job Number: C05083 Page: 14 of 16 AC SYSTEM HEATING AND COOLING LOADS SUMMARY ECT NAME DATE PETCO ANIMAL SUPPLIES INC. 4/3/2006 EM NAME FLOOR AREA AC -1 1,340 Number of Systems 1 Heating System Output per System 99,000 Total Output (Stuh) 99,000 Output (Btuh/sqft) 73.9 Cooling System Output per System 63,900 Total Output (Btuh) 63,900 Total Output (Tons) 5.3 Total Output (Btuh/sqft) 47.7 Total Output (sgft/Ton) 251.6 Air S stem CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.49 Alrflow (cfm/Ton) 375.6 Outside Air (%) 5.1 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions 26.0 OF Outside Air 102 cfm 69.6 OF 12.0 / 77.9 OF Outside Air 102 cfm 74.7/61.7 °F 67.4 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan - Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent CFM Sensible 1,46 29,549 2,680 466 17,360 0 1,477 868 0 0 102 4,030 1,973 102 4,709 0 0 1,477 868 361535 4,653 23 805 1 Lennox LGA060H" 48,035 6,682 Total Adjusted System Output48,035 6,682 (Adjusted for Peak Design Condltlons) TIME OF SYSTEM PEAK I Jul 3 pm 105.0 OF Heating Coll 99,000 99,000 Jan 12 am 105.0 OF Supply Air Ducts g —� Supply Fan 104,6 OF 2000 cfm ROOMS 70.0 OF Return Air Ducts I 76.6 / 62.7 OF 0 55.0 / 53.9 OF, Cooling Coll Supply Fan 2000 cfm 55.0 / 53.9 of —�� Supply Air Ducts 55.7 / 54.2 of 49.2% R.H. ROOMS 74.0 / 61.5 OF K Return Air Ducts 'I EnoroyPro 4.1 by EnergySoft User Number: 5950 Job Number: C05083 Page:16 of 16