Loading...
05-3597 (RC) Title 24I �,- I TITLE 24 REPORT I Title 24 Report for: HIDEAWAY CLUBHOUSE La Quina, Ca 92253 Project Designer: LINITHICUM CORPORATION 20789 North Pima Road, Ste.250 Scottsdale, Az 85255 (480)515-1700 Report Prepared By: R.Krown CEA NR01-99-620 Desert Energy Services P.O. Box 621 Rancho Mirage, CA 92270-0621 (760) 564-2044 C�41, BEC CaliforniaAscot i i,' o,':;u;"dr;::a Er.M Comb* CITY OF LA QUINT - l� *1ErD F'i" 3RGY ANALYST BUILDING & SAFETY DEPA C�R !a RICHARD F. KROWN APPROr. VccE- D Job Number: R 09-93-204 NR 01-99-620 �ZS� R � cR� �� DA OSS $ -/!S/Z 1 Date: 8/31/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with loth the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoR Job Number. 521 User Number. 2366 J I ' TABLE OF CONTENTS I Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -3 Proposed Construction Assembly Form ENV -MM Envelope Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary 1 2 3 24 36 37 39 EnergyPro 3.1 By EnergySoft Job Number. 521 User Number. 2366 jPtRFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME HIDEAWAY CLUBHOUSE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE 8/31/2005 PROJECT ADDRESS 52-500 Hidaway Drive La Quina BUILDING CONDITIONED FLOOR AREA 34,184 sy.FL CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL 0 HIGH RISE RESIDENTIAL HOTEU/MOTEL GUEST ROOM Building Permit # PRINCIPAL DESIGNER - ENVELOPE LINITHICUM CORPORATION TELEPHONE (480)515-1700 n F-] F] 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in DOCUMENTATION AUTHOR Desert Energy Services TELEPHONE 760 564-2044 Checked by/Date Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE OF PLANS s,z7/os BUILDING CONDITIONED FLOOR AREA 34,184 sy.FL CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL 0 HIGH RISE RESIDENTIAL HOTEU/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a B ' g us' t performance compliance approach. DOCUMENTATION AUTHOR R.Krown CEA NR01-99-£20 SIGNA D1713,101 The Principal Designers hereby certify that the proposed buil ng design represented in the construction documents an6 m delled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with thi permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. n El 0 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. n F-] F] 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER -NAME LINITHICUM CORPORATION SIG RE LIC. NO. 8y Sz DA q LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 Required rms PRINCIPAL MECHANICAL DESIGNER - NAME POLAR BARR AIR CONDITIONING SIG =S' LIC. NO. z�r " DATE $ 1 l��S - v Run is io Ti • 08/31105 M25:52 u Code: 1125530752 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:3 of 57 PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 & 3 PERF - DATE HIDEAWAY CLUBHOUSE 8/31/2005 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed Compliance ENERGY COMPONENT Design Design Margin Space Heating 2.51 2.85 -0.34 fsea �. Space Cooling 54.28 54.62 -0.34 Indoor Fans 17.40 20.51 -3.11 Heat Rejection 0.00 0.00 0.00 Pumps 8r Misc. 0.00 0.00 0.00 Domestic Hot Water 22.20 18.31 3.89 Lighting 31.36 31.36 0.00 awy *r Receptacle P 10.52 10.52 0.00 Process 16.51 16.51 0.00 4 x TOTALS: 154.78 154.68 0.10 x -0 SYr: 20 �y 5 30040 s EX15, yr " Percent better than Standard: 0.1°% ( 0.1% excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation North 0 deg Conditioned Floor Area 34,184 sqft. Number of Stories 2 Unconditioned Floor Area 10,845 sqft. Number of Systems 25 Conditioned Footprint Area 21,960 sgft. Number of Zones 37 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation North4,933 sqft. 1,155 sqft. 23.4°% Left Elevation East) 4,080 sqft. 829 sqft. 20.3°% Rear Elevation South 4,677 sqft. 1,157 sqft. 24.7°% Right Elevation (West)l 2,555 sqft. 281 sqft. 11.0°% Total 16,245 sqft. 3,423 sgft.21.1°% Roof 20114 sgft. �sqft. Standard Proposed LEED7 Energy.A Atmosphere Credit Lighting Power Density 1.054 w/sgft. 1.011 wisgft. Savings vs. Title 24' 0.08°% Prescriptive Env. Heat Loss 5,58 Btu/h 5,433 Btufh Energy Performance Credit2 0 Points Prescriptive Env. Heat Gain 528,054 Btulh-F 523,989 Btum-F 1. excludes process and reuptaele 2 see LEED table &e or 8-d Remarks: Standard Building (Compliance) Run Initiation Time: 08/31/0516:25:52 Run Code: 1125530752 EnergyPro 3.1 By Energysoft User Number. 2366 Job Number. 521 Page:4 of 57 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 ONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft) Inst LPD (W/sf)l Port. LPD (Wlsf)1 Ctrl. Credits (W/ 2 Tailored proc. LPD Loads (WIst) 3 (W/Sl) AC -1 A/V & DATA Office 73 '1.300 10.000 SPLIT HEAT PUMP 1A & 1B STAFF LOUNGE Dining Area 561 '1.100 CORRIDOR/R. ROOM Corridor/Restroom/Support 1,955 0.000 0.000 SERVING Kitchen & Food Prep 163 0.000 0.000 STORAGE Industrial Storage 1,578 -0.600 OFFICES Office 227 '1.300 MECH/ELEC Electrical & Mechanical 436 '0.700 UNCONDITIONED Unconditioned 10 845 '0.000 SPLIT HEAT PUMP 2 WINE ROOM Retail/Wholesale Sales 782 '2.000 SPLIT HEAT PUMP 3A ADMINISTRATION Office 1 065 '1.300 SPLIT HEAT PUMP 3B MOVEMENT STUDIO Exercise Center 576 '1.000 SALON Beauty Shop 253 '1.000 WAITING Lobby (Office & Waiting) 496 '1.100 MASSAGE #1 MedicaUClinical Care 163 '1.400 SPLIT HEAT PUMP 4 & 5 FITNESS Exercise Center 2,625 `1.000 SPLIT HEAT PUMP 6 PRO SHOP OFFICE Office 137 '1.300 PRO SHOP Retail/Wholesale Sales 1,231 '2.000 SPLIT HEAT PUMP 7 MASSAGE # 2,3 & 4 Medical/Clinical Care 423 '1.400 WOMEN'S LOUNGE Dining Area 1,502 •1.100 SPLIT HEAT PUMP 8A & 8B WOMENS LOCKER Locker & Dressing Room 1,1561 '0.800 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG4 Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustifrcation and documentation submitted. vi�� cioid The Construction Assembly 8" CMU Underground Wall, Furred has an Outside Absorpbvity of 0.00. The Construction Assembly 6" Concrete Underground Slab Floor has an Outside Absorpbvdy of 0.00. The Construction Assembly R-13 Demising Wall to Unconditioned has an Outside Absorptivity of 0.00. The Construction Assembly 8" CMU Demising Wall, Furred has an Outside Absorptivity of 0.00. The Construction Assembly 12" CMU Underground Wall, Furred has an Outside Absorptivity, of 0.00. The Construction Assembly 8" Solid CMU Demising Wall/R-19 has an Outside Absorptivity of 0.00. The Room "Rooms 106,108,115,116" has a Cooling Indoor Design Temperature of 80 degrees F. The Room "Rooms 114 118" has a Cooling Indoor Design Temperature of 80 degrees F. The Room "Mech/Elev/Cart" has a Heating Indoor Design Temperature of 32 degrees F. The Room "Mech/Elev/Cart" has a Cooling Indoor Design Temperature of 112 degrees F. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant Authorized Signature or Stamp Run Initiation Time: 0813110516:25:52 Run Code: 1125530752 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 521 Page:5 of 57 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 ONE INFORMATION System Name Zone Name Occupancy Type Floor (sgnj Inst (W/D f)1 PorLFCAredlts LPD ( f►1 Tailored Proc, LPD Loads (INlsf) 3 (Nlst) WOMEN'S LOCKER Locker & Dressing Room 523 *0.800 WET AREA Corridor/Restroom/Support 1,547 *0.600 4.000 SPLIT HEAT PUMP 9 CADDY ROOM Office 360 *1.300 SPLIT HEAT PUMP 10 & 13 MEN'S LOCKER Locker & Dressing Room 3,918 *0.800 WET AREA Corridor/Restroom/Support 963 *0.600 4.000 SPLIT HEAT PUMP 11 FOYER/RECEPTION Hotel Function Area 536 *2.200 REST ROOMS/HALL Corridor/Restroom/Support 815 *0.600 OFFICE #1 Office 237 *1.300 INGLENOOK Dining Area 252 *1.100 SPLIT HEAT PUMP 11A PRIVATE DINING 1 Dining Area 627 *1.100 SPLIT HEAT PUMP 12A/12B MEN'S LOUNGE Dining Area 1,986 *1.100 ENTRY Corridor/Restroom/Support 276 *0.600 SPLIT HEAT PUMP 14 BAR/LOUNGE Dining Area 1,378 *1.100 SPLIT HEAT PUMP 15 MIXED GRILL Dining Area 1,627 *1.100 SPLIT HEAT PUMP 15A DINING/DINING 2 Dining Area 914 *1.100 PKG. HEAT PUMP 16 KITCHEN Kitchen & Food Prep 2,277 *1.700 7.500 AC -2 & 3 HOT TUB/STEAM Corridor/Restroom/Support 546 *0.600 10.000 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST ...w o...v.u—ml aueiny srnuuwu pay bpecrar aaenuon io me nems specmea to This cnecxiist. These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant Authorized Signature or Stamp �EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 521 Paoe:6 of 57 ENVELOPE COMPLIANCE SUMMARY Performance ENVA PROJECTNAME ' HIDEAWAY CLUBHOUSE _-------.._ .----..----...--...... vv....m Area -Fac. Act. Azm. SHGC ....w Baum VO.W'. L9rVllll. Glazing Type DATE 8/31/2005 OPAQUE SURFACES 48 64 0.500 0.500 180 90 0.40 0.40 Double NonMtl Low E Default Double NonMt1 Low E Default NAITING WASSAGE#1 Surface Framing # Type Type Area Act. U -Fac. Azm. Tilt Solar Gains YIN Form 3 Reference Location /Comments 1 Wall Wood 108 0.065 180 90 R-19 Wall .19.2x6.16 A/V & DATA 2 IDoor INone 24 1. 0.387 180 90 Solid Wood Door A/V & DATA 3 Wall Metal 0 0.338 270 90 8" Solid CMU WaIV1.5' Ri id A/V & DATA 4 Roof Wood 0.40 0.40 0.40 0.203 0 0 Earth/Slab/S ancrete STAFF LOUNGE 5 WaIIBG Metal P221 0.190 0 90 12"CMU Und round Wall, Furred STAFF LOUNGE - 162"dee6 Roof Wood 0.203 0 0 Earth/Slab/S ancrete CORRIDOR/R. ROOM 7 Wall Wood 0.065 0 90 R-19Wall .19.2x6.16 CORRIDOR/R. ROOM 8 Wall Wood 1 0.065 90 90 R-19 Wall .19.2x6.16 CORRIDOR/R. ROOM 9 Door None 24 0.387 90 90 X I I Solid Wood Door CORRIDOR/R. ROOM 10 Wall Metal 319 0.338 270 90 X L J 8" Solid CMU Wall/1.5" Rigid CORRIDOR/R. ROOM 11 Door None 48 0.581 270 90 Hollow Metal Door CORRIDOR/R. ROOM 12 Door None 96 0.581 270 90 Roll u Metal Door CORRIDOR/R. ROOM, 13 Vemisinq 14 lRoof Metal lWood 1,122 1,578 0.338 0.203 0 0 90 0 X 8" CMU Demising Wall Furred Earth/Slab/S ancrete CORRIDOR/R. ROOM faces Mech/Elev/Ca STORAGE 15 JWallBG IMetal 419 0.190 0 90 12" CMU Under round Wall Furred STORAGE -162" dee 16 Demising 17 Roof Metal Wood 306 125 0.338 0.203 0 0 1 90 0 8" CMU Demising Wall, Furred IX I Earth/Slab/S ancrete STORAGE faces Mech/Elev/Cart OFFICES 18 WallBG Metal 125 0.190 0 90 11 X 112" CMU Underground Wall Furred OFFICES -162" dee 19 Demising 20 Roof Metal Wood 1290 158 1 0.338 1 0.203 0 0 90 0 1 11 X18"CMU Demising Wall, Furred 1X11 lEarttVSlab/Spancrete OFFICES faces Mech/Elev/Cart MECH/ELEC FENESTRATION SURFACES _ r-. /.L�-L Lam__ l l�.-•.�-_ _ _ www ww.. .. . ��. 0.76 .....,....v o v. v. n anu w,vuu a n mmai giazmg men NML, ueraricanon is required. _ # Type _-------.._ .----..----...--...... vv....m Area -Fac. Act. Azm. SHGC ....w Baum VO.W'. L9rVllll. Glazing Type Location / Comments 1 Window 2 Window 48 64 0.500 0.500 180 90 0.40 0.40 Double NonMtl Low E Default Double NonMt1 Low E Default NAITING WASSAGE#1 3 Window 96 0.500 0 _ 0.40 Double NonMt1 Low E Default ITNESS 4 Window 96 0.500 90 0.40 Double NonMtl Low E Default r1TNESS 5 lWindow 6 JWindow 48 92 0.500 0.520 90 90 0.40 0.40 Double NonMt1 Low E Default Double NonMtl Low E Default ITNESS ITNESS 7 lWindow 46 0.520 0 0.40 1 Double NonMt1 Low E Default RO SHOP 8 Window 9 lWindow 10 lWindow 78 69 24 0.520 0.520 0.520 90 180 180 0.40 0.40 0.40 1 Double NonMtl Low E Default Double NonMtl Low E Default Double NonMt1 Low E Default RO SHOP RO SHOP IRO SHOP 11 Window 180 0.40 Double NonMt1 Low E Default RO SHOP 12 Window 13 Window 14 Window 15 Window A48O.500 180 180 180 180 0.40 0.40 0.40 0.40 Double NonMt1 Low E Default Double NonMtl Low E Default Double NonMtl Law E Default Double NonMti Low E Defautt OMEN'S LOUNGE OMEN'S LOUNGE ET AREA ET AREA EXTERIOR SHADING # Exterior Shade Type 1 None SHGC 0.76 Window Hgt. Wd. 8.0 6.0 Overhang Left Fin Right Fin Len. Hgt. LExt.RExt. Dist. Len. H t. Dist. Len. Hgj. 99.0 0.1 99.0 99.0 2 None 0.76 8.0 8.0 12.0 0.1 99.0 99.0 3 None 0.76 4 None 0.76 5 None 0.76 8.0 6.0 12.0 0.1 99.0 99.0 6 None 0.76 7 None 0.76 8 None 0.76 9 None 0.76 7.5 9.2 19.0 4.0 99.0 9.0 10 None 0.76 7.5 9.2 19.0 4.0 99.0 22.0 11 None 0.76 8.0 6.0 19.0 4.0 99.0 24.0 12 None 0.76 7.5 9.2 13.0 4.0 99.0 99.0 13 None 0.76 7.5 9.2 -13.0 4.0 99.0 99.0 14 None 0.76 7.5 9.2 25.0 4.0 99.0 99.0 15 one 0.76 1 8.0 E 25.0 4.0 99.0 99.0 Run Initiation Time: 08131/05 16:25:5Code: 112553075 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 521 Page:? of 57 JENVtLOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME HIDEAWAY CLUBHOUSE Area JU-Fac. Act. Azm. SHGC DATE 8/31/2005 OPAQUE SURFACES 16 Window 140 0.500 0 0.40 Double NonMtI Low E Default OYER/RECEPTION . Surface Framing it Type Type Act. Area U -Fac. Azm. Tilt Solar Gains . YIN Form 3 Reference Location I Comments 21 Demising Metal 475 0.338 0 90 1 11 XIFEM_uDemisingWall Furred MECH/ELEC faces Mech/Elev/Cart 22 Wall Wood 256 1 0.065 0 90 R-19 Wall.19.2x6.16 WINE ROOM 23 Wall Wood 73 0.065 90 90 R-19 Wall .19.2x6.16 WINE ROOM 24 Demisina Metal 88 0.338 0 90 11 X18"CMU Demising Wall Furred WINE ROOM faces Mech/Elev/Cart 25 Roof Wood 1,065 0.203 0 0 X I I Earth/Slab/S ancrete ADMINISTRATION 26 Wall Metal 39 0.338 90 90 8" Solid CMU Wall/1.5" Rigid ADMINISTRATION 27 Door None 24 0.387 90 90 Solid Wood Door ADMINISTRATION 28 Wall Metal 13 0.338 180 1 90 X 8" Solid CMU Wall/1.5" Ri id ADMINISTRATION 29 WaIIBG Metal 544 1 0.190 0 90 x 12" CMU Underground Wall Furred ADMINISTRATION -162" dee 30 Demising Metal 242 0.338 0 90 1 X 8" CMU Demising Wall, Furred ADMINISTRATION faces Mech/Elev/Cart 31 Wall Metal 94 0.338 180 90 Ix 8" Solid CMU Wall/1.5" Rigid MOVEMENT STUDIO 32 Wall Metal 100 0.338 270 90 IXI 18" Solid CMU Wall/1.5" Rigid MOVEMENT STUDIO 33 WaIIBG Metal 413 0.190 0 90 1 X 112" CMU Underground Wall Furred MOVEMENT STUDIO -162" dee 34 Wall Wood 169 0.065 180 90 R-19 Wall .19.2x6.16 SALON - 35 Wall Wood 78 0.060 90 90 x 8" Solid CMU Demising Wall/R-19 WAITING 36 Wall Wood 227 1 0.065 180 90 X R-19 Wall .19.2x6.16 WAITING 37 Wall Wood 89 0.060 90 90 8" Solid CMU Demising Wall/R-19 MASSAGE #1 38 WaIIBG Metal 932 0.190 0 90 A 12" CMU Underground Wall Furred FITNESS -162" dee 39 Wall Wood 192 0.060 1 1 90 1 L 8" Solid CMU Demising Wall/R-19 FITNESS 40 lWall Wood 466 0.060 90 90 11 X1 8" Solid CMU Demising Wall/R-19 IFITNESS FENESTRATION SURFACES 27 None 0.76 8.0 6.0 13.0 Site Assembled GlazingU %,nmR oox n Duuaing is - i06,600 sqn or GFA and - IU,Uuu sqtt vertical glazing then NFRC Certification is required. cnii . ripor 1M_CR -i Racor, i ..k i - _"r........ # Type Area JU-Fac. Act. Azm. SHGC Glazing Type Location/ Comments 16 Window 140 0.500 0 0.40 Double NonMtI Low E Default OYER/RECEPTION . 17 Window 30 0.520 0 0.40 Double NonMtI Low E Default 3FFICE #1 18 Window 30 0.520 0 0.40 Double NonMO Low E Default NGLENOOK 19 Window 30 0.520 270 0.40 Double NonMtl Low E Default INGLENOOK 20 Window 45 0.520 1 0 0.40 Double NonMtl Low E DefaultINTRY IVATE DINING 1 21 Window 64 0.500 0 0.40 Double NonMtl Low E Default IVATE DINING 1 22 Window 82 0.520 180 0.40 Double NonMtl Low E Default IVATE DINING 1 23 Window 82 0.520 270 0.40 Double NonMtl Low E Default IVATE DINING 1 24 Window 95 0.520 90 0.40 Double NonMtl Low E Default N'S LOUNGE 25 Window 95 0.520 90 0.40 Double NonMtl Low E Default N'S LOUNGE 26 Window 47 0.520 90 0.40 Double NonMt1 Low E Default N'S LOUNGE 27 Window 48 0.500 90 0.40 Double NonMti Low E Default N'S LOUNGE 28 Window 261 0.520 180 0.40 Double NonMU Low E Default N'S LOUNGE 29 Window 51 0.520 0 0.40 Double NonMtl Low E Default TRY 30 Window 24 0.500 0 0.40 Double NonMtt Low E Default EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hgt. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 16 None 0.76 10.0 14.0 29.0 0.1 99.0 99.0 17 None 0.76 5.0 6.0 14.0 2.0 99.0 99.0 18 None 0.76 5.0 3.0 15.0 2.0 99.0 2.0 19 None 0.76 5.0 3.0 15.0 2.0 2.0 99.0 20 None 0.76 7.5 14.0 17.0 2.0 99.0 2.0 21 None 0.76 8.0 8.0 17.0 2.0 99.0 2.0 22 None 0.76 5.8 14.0 38.0 2.0 3.0 99.0 23 None 0.76 24 None 0.76 25 None 0.76 26 None 0.76 9.5 10.0 13.0 2.0 15.0 99.0 27 None 0.76 8.0 6.0 13.0 2.0 15.0 99.0 28 None 0.76 9.5 9.2 13.0 2.0 99.0 15.0 29 None 0.76 7.5 8.8 99.0 0.1 99.0 99.0 30 None 0.76 8.0 3.0 99.0 0.1 99.0 99.0 Run Initiation Time: 08/31/05 6:25:52 Run Code- 11255 075 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 521 Page:8 of 57 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME HIDEAWAY CLUBHOUSE Area -Fac. Act. Azm. SHGC DATE 8/31/2005 OPAQUE SURFACES 31 Window 268 0.520 0 0.40 Double NonMtl Low E Default AR/LOUNGE Surface Framing it Type Type Act. Area U -Fac. Azm. Tilt Solar Gains YIN Form 3 Reference Location I Comments 41 Wall Imetal 140 0.338 0 90 1 X 8" Solid CMU Wall/1.5" Rigid PRO SHOP OFFICE 42 Wall Wood 119 0.065 0 90 1 & R-19 Wall .19.2x6.16 PRO SHOP 43 lWall IMetal 272 0.338 0 90 1 X 8" Solid CMU Wall/1.5" Rigid PRO SHOP 44 Wall Metal 428 0.338 90 90 IX 8" Solid CMU Wall/1.5" Rigid PRO SHOP 45 Wall Wood 297 0.065 180 90 2L R-19 Wall .19.2x6.16 PRO SHOP 46 Wall Wood 359 0.060 0 90 X 8" Solid CMU Demising Wall/R-19 MASSAGE # 2,3 & 4 47 Door None 72 0.387 0 90 X1 I Solid Wood Door MASSAGE # 2,3 & 4 48 Wall Wood 73 0.065 270 90IL R-19 Wall .19.2x6.16 MASSAGE # 2, 3 & 4 49 Wall Wood 65 0.065 0 90 x R-19 Wall .19.2x6.16 WOMEN'S LOUNGE 50 Door None 48 0.387 0 90 Solid Wood Door WOMEN'S LOUNGE 51 Wall Metal 206 0.338 180 90 IX 8" Solid CMU WaII/1.5" Rigid WOMEN'S LOUNGE 52 Demising Wood 852 0.060 0 90 8" Solid CMU Demising Wall/R-19 WOMENS LOCKER faces Mech/Elev/Cart 53 Wall Wood 0 0.065 90 90 IX R-19 Wall .19.2x6.16 WOMEN'S LOCKER 54 Demising Metal 206 0.338 0 90 1 IX18"CMU Demising Wall, Furred WOMEN'S LOCKER faces Mech/Elev/Cart 55 Roof Wood 264 0.342 0 0 1 x I I Slab/Spancrete WET AREA 56 Wall Metal 272 0.338 180 90 X1 18" Solid CMU Wall/1.5" Rigid WET AREA 57 Wal[BG Metal 516 0.202 0 90 X 18" CMU Underground Wall, Furred CADDY ROOM -162" dee 58 Demising Metal 525 0.338 0 90 x8" CMU Demising Wall Furred ICADDY ROOM faces Mech/Elev/Cart 59 Roof Wood 13,918 0.030 0 0 1 Tile Roof/R-38 MEN'S LOCKER 60 Wall Wood 502 1 0.065 1 0 90 R-19 Wall .19.2x6.16 MEN'S LOCKER FENESTRATION SURFACES 42 None 0.76 Site Assembled Glazing U uox �� nuuainu is iuu,uuu squ or %,rH ana - 1u,uuu sgrt vemcai glazing then NFRC Certification is required. Fnllnw NFRC` 1rf1_SR Pmrs+A��rnc .1 c..hmif tdror, I h-1 r .... # 'Type Area -Fac. Act. Azm. SHGC Glazing Type Location I Comments 31 Window 268 0.520 0 0.40 Double NonMtl Low E Default AR/LOUNGE 32 Window 192 0.500 0 0.40 Double NonMd Low E Default AR/LOUNGE 33 Window 200 0.500 180 0.40 Double NonMU Low E Default IXED GRILL 34 Window 64 0.520 270 0.40 Double NonMtl Low E Default IXED GRILL 35 Window 30 0.520 90 0.40 Double NonMtl Low E Default INING/DINING 2 36 Window 44 0.520 90 0.40 Double NonMO Low E Default INING/DINING 2 37 Window 48 0.500 90 0.40 Double NonMtl Low E Default INING/DINING 2 38 Window 44 0.520 90 0.40 Double NonMtl Low E Default INING/DINING 2 39 Window 83 0.520 180 0.40 Double NonMtl Low E Default INING/DINING 2 40 Window 85 0.520 180 0.40 Double NonMtl Low E Default INING/DINING 2 41 Window 48 0.500 180 0.40 Double NonMtl Low E Default INING/DINING 2 42 Window 146 0.520 0 0.40 Double NonMU Low E Default JOT TUB/STEAM 43 Window 24 0.500 0 0.40 Double NonMtl Low E Default JOT TUB/STEAM 44 Window 106 0.520 270 0.40 Double NonMtl Low E Default IOT TUB/STEAM fill EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hgt. LExt.RExt. Dist. Len. -Hgt. Dist. Len. Hgt. 31 None 0.76 11.5 10.0 6.0 2.0 36.0 99.0 32 None 0.76 8.0 6.0 6.0 5.5 36.0 99.0 33 None 0.76 10.0 20.0 6.0 2.0 6.0 6.0 34 None 0.76 7.5 8.5 14.0 2.0 99.0 13.0 35 1 None 0.76 5.0 6.0 13.0 2.0 14.0 99.0 36 1 None 0.76 7.5 5.8 26.0 2.0 1.0 99.0 37 1 None 0.76 38 1 None 0.76 39 1 None 0.76 40 None 0.76 41 None 0.76 42 None 0.76 43 None 0.76 44 None 0.76 Run Initiation Time: 08/31/05 16:25:52 u Code: 1125530752 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:9 of 57 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 OPAQUE SURFACES Surface Framing # Type Type Act. Area U -Fac. Azm. Tilt Solar Gains YIN Form 3 Reference Location I Comments 61 Door None 24 0.387 0 90 Solid Wood Door MEN'S LOCKER 62 Wall Wood 1.064 0.065 90 90 & I R-19 Wall .19.2x6.16 MEN'S LOCKER 63 all Wood 330 0.065 270 90 & I R-19 Wall .19.2x6.16 MEN'S LOCKER 64 Roof Wood 963 0.030 0 0 X I Tile Roof/R38 WET AREA 65 Wall Metal 242 0.338 180 90 X 18" Solid CMU Wall/1.5" Rigid— WET AREA 66 Wall Metal 149 0.338 270 90 X 8" Solid CMU Wall/1.5" Rigid WET AREA 67 Wall Wood 149 0.065 270 90 x R-19 Wall .19.2x6.16 WET AREA 68 Demising Metal 77 0.338 0 90 8" CMU Demising Wall, Furred WET AREA faces Mech/Elev/Cart 69 IFloor None 536 1 0.188 0 180 X Carpet/55" Conc/10" S ancrete FOYER/RECEPTION 70 IRoof Wood 536 1 0.030 0 0X Tile Roof/R-38 FOYER/RECEPTION 71 lWall Wood 100 0.065 0 90 R-19 Wall .19.2x6.16 FOYER/RECEPTION 72 IFloor None 352 0.188 0 180 1 IXICan)eV5.5"Conc/10"Spancrete REST ROOMSIHALL 73 Roof Wood 815 0.030 0 0 X I Tile Roof/R38 REST ROOMS/HALL 74 Wall Wood 169 0.065 0 90 R-19 Wall .19.2x6.16 REST ROOMSIHALL 75 Wall Wood 33 0.065 270 1 90 X R-19 Wall .19.2x6.16 REST ROOMS/HALL 76 Roof Wood 237 1 0.030 0 1 0 X Tile Roof/R-38 OFFICE #1 77 Wall Wood 204 0.065 0 90 R-19 Wall .19.2x6.16 OFFICE#1 78 Wall Wood 165 0.065 270 90 R-19 Wall .19.26.16 OFFICE #1 79 Floor None 252 0.188 0 180 Ca 5.5" Conc/10" Spancrete INGLENOOK 80 Roof Wood 252 0.030 0 0 Tile Roof/R-38 JINGLENOOK FENESTRATION SURFACES one mssemorea viazmg - -- --•-••--.._.....- --'..... — .....,. - - .y.. V -415y Ul�lj 4jVM%, %,ciuucauun is u requea. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form. #I Type Area U -Fac. Act. Azm. I SHGC I Glazing Type Location / Comments Exterior Shade Wd. Left Fin I _ Right Fin —] Run Initiation Time: 08/31/05 16 5.52 Run Code, 1125530752 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 521 Page: 10 of 57 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME HIDEAWAY CLUBHOUSE '___- .'. .'_ . _- �� . �............. ...... v..v.nn ... ..v Lau.. — 111 VULC OR11. Area JU-Fac. Act. Azm. SHGC Glazing Type Location / Comments DATE 8/31/2005 OPAQUE SURFACES Surface Framing # Type I Type Act. Area U -Fac. Azm. Tilt Solar Gains YIN Form 3 Reference Location / Comments 81 Wall Wood 185 0.065 0 90 X11 IR-19Wall .19.2x6.16 INGLENOOK 82 Wall Wood 181 1 0.065 270 1 90 X11 IR-19Wall .19.26.16 INGLENOOK 83 Floor None 627 0.188 0 180 Ca 5.5" Conc/10" Spancrete PRIVATE DINING 1 84 Roof Wood 627 0.030 0 0 Tile Roof/R-38 PRIVATE DINING 1 85 Wall Wood 102 0.065 0 90 X R-19 Wall W.19.2x6.16 PRIVATE DINING 1 86 Wall Wood 142 0.065 180 90 R-19 Wall .19.26.16 PRIVATE DINING 1 87 Wall 1Wood 155 0.065 270 90 R-19 Wall .19.2x6.16 PRIVATE DINING 1 88 Roof Wood 1,986 0.030 0 0 1XII Tile Roof/R-38 MEN'S LOUNGE 89 Wall 90 Wall Wood Wood 143 261 0.065 0.065 0 90 90 90 X11 IR-19Wall .19.26.16 R-19 Wall .19.24.16 MEN'S LOUNGE MEN'S LOUNGE 91 Wall 92 lRoof Wood Wood 350 276 0.065 0.030 180 0 90 0 R-19 Wall .19.2x6.16 Tile Roof/R-38 MEN'S LOUNGE ENTRY 93 all Wood 51 0.065 0 90 x R-19 Wall .19.26.16 ENTRY 94 Floor None 1,378 0.188 0 180 Carpet/5.5" Conc/10" S ancrete BAR/LOUNGE 95 Roof Wood 1,378 0.030 0 0 Tile Roof/ BAR/LOUNGE 96 Wall ood 260 0.065 0 90 X11 JR-19WMF(W.119.24.16)BARILOUNGE 97 Roof lWood 162 0.030 0 0 Tile Roof/R-38 MIXED GRILL 98 WallWood 418 0.065 180 90 R-19 Wall .19.2x6.16 MIXED GRILL 99 all Wood 256 1 0.065 270 1 90 R-19 Wall 19.2x6.16 MIXED GRILL 100 RoofWood 1914 1 0.030 0 1 0 Tile Roof/R-38 DINING/DINING 2 FENESTRATION SURFACES arte Assernmea Glazing""" " ""^ " """""'y vv,uw -141t V! a.rn dnu 1 u,uuu 5qr[ vemcal glazing men Nt-KG Gertification is required. Fnllrnar NFRr: 1flrLQR D•nnA A ....L...a wlcon 1 _L_I n_�r.- # Type '___- .'. .'_ . _- �� . �............. ...... v..v.nn ... ..v Lau.. — 111 VULC OR11. Area JU-Fac. Act. Azm. SHGC Glazing Type Location / Comments EXTERIOR SHADING # Exterior Shade Type Window Overhang Left Fin SHGC Hgt. Wd. Len. H . LExt.RExt. Dist. Len. Hgt. Right Fin Dist. Len. H t. Run Initiation Time• 08/31/05 16:25-,52 Run Code: 1125530752 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 521 Page: 11 of 57 [ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME HIDEAWAY CLUBHOUSE ON— AUM1111i Mr -M, ldUCl V,WU1lGaIe rOrM. Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments DATE 8/31/2005 OPAQUE SURFACES Surface Framing # Type Type 101 Wall Wood 102 all Wood 103 Roof 104 Wall Wood 105 Wall Wood 106 Demising Wood 107 Roof Wood 108 Wall Metal 109 Wall Metal 1118 11ODernising Metal Act. Area U -Fac. Azm. 629 0.065 90 957 0.065 180 2,277 0.030 0 309 0.065 0 36 0.065 90 254 0.084 0 546 0.030 0 1 168 0.338 0 1 0.338 270 228 0.338 0 Tilt 90 90 0 90 90 90 0 90 90 90 Solar Gains YIN Form 3 Reference R-19 Wall .19.26.16 X I R-19 Wall .19.2x6.16 X I B/U Roof/R-8 R-19 Wall .19.2x6.16 R-19 Wall .19.2x6.16 1 X R-13 Demising Wall to Unconditioned x Tile Roof/R-38 4 8" Solid CMU Wall/1.5" Rigid X 8" Solid CMU Wall/1.5" Rigid 8- CMU Demising Wall, Furred Location / Comments DINING/DINING 2 DINING/DINING 2 KITCHEN KITCHEN KITCHEN KITCHEN faces Mech/Elev/Cart HOT TUB/STEAM HOT TUB/STEAM HOT TUB/STEAM HOT TUB/STEAM faces Mech/Elev/Cart EXTERIOR SHADING # Exterior Shade Type Window Overhang Left Fin SHGC Hgt. Wd. Len. Hgj. LExt.RExt. Dist. en. H Right Fin t. Dist. Len. H t. FENESTRATION SURFACES Site Assembled Glazing F] Check box if Building is —100,000 sqft of CFA and —10,000 sqft vertical glazing then NFRC Certification is required. # Type ON— AUM1111i Mr -M, ldUCl V,WU1lGaIe rOrM. Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments EXTERIOR SHADING # Exterior Shade Type Window Overhang Left Fin SHGC Hgt. Wd. Len. Hgj. LExt.RExt. Dist. en. H Right Fin t. Dist. Len. H t. Run n" is " Time: 08/31105 16:25,52 Co e• 1125530752 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 521 Page: 12 of 57 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE DHW Heater I I AC -1 I I SPLIT HEAT PUMP 1A & n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Gas Fired 91% n/a n/a A O SMITH BTH-250 Yes Yes n/a n/a n/a n/a n/a Switch n/a Yes 0.0 kW Constant Volume No Cert. 10.1 EER LENNOX HP2 Yes Yes Ducts in Conditione Ducts in Conditione No CODE TABLES: Enter code from table below into columns above. NOTE TO FIELD I EnergyPm 3.1 By EnergySoft User Number. 2366 Job Number. 521 ____Page. 13 of 57 CERTIFICATE OF COMPLIANCE Performance MECH-1 (PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-0 COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R VALUE COOLING DUCT LOCATION R VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE SPLIT HEAT PUMP 2 Programmable Switch Heating & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem Na Outside Air Cert Gravity No Economizer 196 cfm Heat Pum 8.00 HSPF S lit DX 11.1 SEER / 9.5 EER LENNOX HP29-036-'P Yes Yes Ducts in Conditioned Na Ducts in Conditioned Na No SPLIT HEAT PUMP 3A Programmable Switch Heating & Cooling Required n/a Yes 7.5 kW Constant Volume No No Constant Tem Constant Tem Na Outside Air Cert. Gravity No Economizer 160 cfm Heat Pum 7.50 HSPF Split DX 11.0 SEER / 9.4 EER LENNOX HP29-04VP Yes Yes Ducts in Conditioned Na Ducts in Conditioned I Na No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes 0: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V: VFD SIMULTANEOUS HEAT / COOL? Y: Yes M: Manual Timer O: Other C: Curve --- - - --- - -- ------ N: No PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air Cert G: Gravity W: Water CFM. M: Out Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. I EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 521 Paoe:14 of 57 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 YSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME SPLIT HEAT PUMP 4 & 5 1 SPLIT HEAT PUMP 6 SPLIT HEATf PUMP 7 NOTETO n Programmable Switch Heatinq & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem Na Outside Air Cert. Gravity No Economizer 814 cfm Heat Pum 320 COP Split DX 10.1 EER LENNOX HP29-090 Yes Yes Ducts in Conditioned Na Ducts in Conditioned Na No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N. No TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog• Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER OA CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert M: Out Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air : Water N: Not Required EC: Economizer Control See Section 1 AAfals Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPACE Run Initiation Time: 08/31/0516.25.52 Run Code: 1125530752 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page: 15 of 57 CERTIFICATE OF COMPLIANCE Performance MECH-1 17 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 YSTEM FEATURES SYSTEM NAME SPLIT HEAT PUMP 8A & Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Outside Air Cert. Gravity No Economizer 484 cfm Heat Pum 7.20 HSPF Split DX 11.0 SEER / 9.4 EER LENNOX HP29-060-'P Yes Yes Ducts in Conditioned n/a Ducts in Conditioned n/a No SPLIT HEAT PUMP 9 SPLIT HEAT PUMP 10 & 13 CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch 0: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD 0: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT I COOL? HEAT AND COOL SUPPLY RESET? VENTILATION JOUTDOORDAMPER1 ECONOMIZER O A CFM PIPE INSULATION REQUIRED? C: Outside Air Cert G: Gravity W: Water CFM. PIPEIDUCT INSULATION PROTECTED? M: Out Air Measure D: Demand Control N: Not Required EC: Economizer Note: This shall be no less than Col. H on SEALED DUCTS IN CEILING/ROOF SPACE N: Natural Control See Section MECH-3. 1 e3 NOTES -TO LD - Fo a Use Only Run Initiation Time: 08/31/0516:25.52 Run Code: 1125530752 EnergyPro 3.1 By EnergySoft User Number. 2368 Job Number. 521 Page: 16 of 57 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME •DATE HIDEAWAY CLUBHOUSE 8/31/2005 YSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME —� SPLIT HEAT PUMP 11 SPLIT HEAT PUMP 11A SPLIT HEAT PUMP I NOTE TO Programmable Switch Healing & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 552 chn Heat Pum 3.20 COP Split DX 10.1 EER LENNOX HP29-090 Yes Yes Ducts in Conditioned n/a Ducts in Conditioned n/a No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 314 cfm Heat Pum 720 HSPF Split DX 11.0 SEER / 9.4 EER LENNOX HP29-06VP Yes Yes Ducts in Conditioned n/a Ducts in Conditioned n/a No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 1034 cfm Heat Pum 320 COP Split DX 10.1 EER LENNOX HP29-090 Yes Yes Ducts in Conditioned n/a Ducts in Conditioned n/a No CODE TABLES: Enter code from table below into columns above HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch 0: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of I: Inlet Vanes Isolation Zones. P: Variable Pitch V: VFD 0. Other C• Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A• CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert M: Out Air Measure D: Demand Control N: Natural A: Auto G: Gravity A. Air : Water N: Not Required EC: Economizer Control See Section 1 e3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPACE Only OTES TO FIELD- e Run Initiation Time: 08/31/0516:25:52 Run Code: 1125530752 EnergyPro 3.1 By Energysoft User Number. 2366 Job Number. 521 Page: 17 of 57 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE Programmable Switch Heating & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 689 cfm Heat Pum 3.20 COP Split DX 10.1 EER LENNOX HP29-120 Yes Yes Ducts in Conditioned Na Ducts in Conditioned Na No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: NoVENTILATION TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL - ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD 0: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? OUTDOOR DAMPER ECONOMIZER OA CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air CerL M: OuL Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air : Water N: Not Required EC: Economizer Control See Section Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH�. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPACE v v- Run Initiation Time: 08/31/0516:25:52 Run Code: 1125530752 EnergyPm 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page: IS of 57 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE MECHANICAL SYSTEMS PKG. HEAT PUMP 16 11 AG -2 & 3 Programmable Switch Heafinq & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Outside Air Cert Gravity No Economizer 342 cfm Heat Pum 3.10 COP Packaged DX 10.0 EER LENNOX THA150S Yes Yes Ducts in Conditioned n/a Ducts in Conditioned n/a No Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 82 cfm None n/a Split DX 10.0 SEER/ 9.0 EER DECTRON MAM-030 Yes Yes Ducts in Conditioned n/a Ducts in Conditioned n/a No NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch 0: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B• Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD 0: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM . HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert M: Out Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 1 e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH4. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPACE Run Initiation Trane: 08/31/0516:25:52 Run Code: 11255 075 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 521 Page: 19 of 57 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 CHILLER AND TOWER SUMMARY Efficiency Tons PUMPS Motor Location Equipment Name Equipment Type Qty. Tot Qty GPM BHP Motor Eff. Drive Eff. pump Control Constant Volume Blow -Through 800 0.20 77.0% 100.0% none LENNOX HP29-090 Constant Volume Draw -Through 2,900 0.75 77.0% 97.0% none LENNOX HP29-036-'P Constant Volume Blow Through 1,1001 0.25 77.0%1100.0%1 DHW / BOILER SUMMARY none TANKINSUL. Energy Factor or Recovery Efficiency Standby Loss or Pilot System Name System Type Distribution Type Qty Rated I Input (Gals.) Vol. Ext R -Val. O SMITH BTH-250-"' Large Gas Standard 1 240,000 100 0.91 0.0126 0.0 none LENNOX HP29-060-'P Constant Volume Blow -Through 1,900 0.50 77.0% 100.0% none LENNOX HP29-024-'P CENTRAL SYSTEM RATINGS HEATING COOLING System Name LENNOX HS29-024-'P' System T Split DX . 1 Output 0 Aux. kW 0.0 I Eff, n/a Output 24,200 Sensible 16,94011.0 Efficiency SEER / 10.0 EER Economizer Type No Economizer LENNOX HP29-090 Split DX 111 85,000 0.0 320 COP 94,500 70,87510.1 EER No Economizer LENNOX HP29-03VP Split DX 1 34,400 0.0 8.00 HSPF 35,400 24,78011.1 SEER / 9.5 EER No Economizer LENNOX HP29-048-'P LENNOX HP29-060 'P S fit DX Split DX 1 5 43,500 55,0001 7.5 0.0 7.50 HSPF 7.20 HSPF 44,000 58,000 30,80011.0 40,60011.0 SEER / 9.4 EER SEER 19.4 EER No Economizer No Economizer LENNOX HP29-024-'P Split DX 1 21,200 5.0 7.20 HSPF 24,000 16,800 1.1 SEER / 9.9 EER No Economizer LENNOX Split DX 2 120,000 0.0 3.20 COP 124,500 92,13010.1 EER No Economizer LENNOX THA150S HA150S Packaged DX 1 140,000 0.0 3.10 COP 144,000 100,800 10.0 EER No Economizer DECTRON MAM-030 Split DX 2 0 0.0 nIa 34,000 18,000 10.0 SEER / 9.0 EER No Economizer I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Pege:20 of 57 system Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eft. Drive Eff. LENNOX HS29-024-'P' Constant Volume Blow -Through 800 0.20 77.0% 100.0% none LENNOX HP29-090 Constant Volume Draw -Through 2,900 0.75 77.0% 97.0% none LENNOX HP29-036-'P Constant Volume Blow Through 1,1001 0.25 77.0%1100.0%1 none LENNOX HP29-048-'P Constant Volume Blow -Through 1,500 0.33 77.0%1100.0% none LENNOX HP29-060-'P Constant Volume Blow -Through 1,900 0.50 77.0% 100.0% none LENNOX HP29-024-'P Constant Volume Blow -Through 765 0.20 77.0°x6 100.0% none LENNOX HP29-120 Constant Volume Draw -Through 3,800 1.001 82.5% 97.0%1 none LENNOX THA150S Constant Volume Blow -Through 4,800 1.50 84.0%1 97.0% none DECTRON MAM-030 Constant Volume Blow -Through 600 0.25 77.0% 100.0% none I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Pege:20 of 57 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2� PROJECT NAME HIDEAWAY CLUBHOUSE I DATE R/11119nnR VAV TERMINAL BOX TERMINAL FAN Min. CFM Reheat Coil Motor Drive System Type Qtv. Ratio Type DeftaT CFM BHP Eff. Eff. EXHAUSTFAN Room Name CFM BHP Motor Eff. Drive Eff. Type KAUMAN- Motor Drive Room Name CFM BHP Eff. Eff. Output EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:21 of 57 1 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 MECHANICAL VENTILATION a © a o a o© a a a o ZONEISYSTEM & DATA AC -1 STAFF LOUNGE CORRIDOR/R. ROOM SERVING STORAGE OFFICES MECH/ELEC SPLIT HEAT PUMP 1A & 1B WINE ROOM SPLIT HEAT PUMP 2 ADMINISTRATION SPLIT HEAT PUMP 3A MOVEMENT STUDIO SALON WAITING MASSAGE #1 SPLIT HEAT PUMP 3B FITNESS SPLIT HEAT PUMP 4 & 5 PRO SHOP OFFICE PRO SHOP SPLIT HEAT PUMP 6 MASSAGE # 2, 3 & 4 OMEN'S LOUNGE SPLIT HEAT PUMP 7 WOMENS LOCKER WOMEN'S LOCKER AREA BASIS DESIGN OUTDOOR AIR CFM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) 73 0.15 11 11 11 561 0.50 280 1,955 0.15 293 163 0.15 24 1,578 0.15 237 227 0.15 34 436 0.15 65 34 782 0.25 196 934 934 1,065 0.15 160 196 576 0.15 86 2531 0.40 101 496 0.15 74 163 0.15 24 86 86 2,625 0.15 394 74 137 0.15 21 1,231 0.25 308 286 286 423 0.15 63 1,502 0.50 751 394 394 1,156 0.15 173 5231 0.15 78 OCCUPANCY BASIS NO. CFM MIN. OF PER CFM PEOPLE PERSON (EXF) Total Total Total Total Total Total Total Total REQ'D O A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO TRANS FER AIR 11 11 11 11 280 280 293 293 24 24 237 237 34 34 65 65 934 934 196 196 196 196 160 160 160 160 86 86 101 101 74 74 24 24 286 286 394 394 394 394 21 21 308 308 328 328 63 63 751 751 814 814 173 173 78 78 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 521 Paae:22 of 57 1 IMECHANICAL VENTILATION MECH-3 (PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 -] MECHANICAL VENTILATION a a© o 0 o a a a o 0 AREA BASIS COND. AREA (SF) CFM PER SF MIN. CFM (B x C) 1,547 0.15 232 360 0.15 54 3,918 0.15 588 963 0.15 144 536 0.50 268 815 0.15 122 237 0.15 36 252 0.50 126 627 0.50 314 1,986 0.50 993 276 0.15 41 1,378 0.50 689 1,627 0.50 814 914 0.50 457 2,277 0.15 342 546 0.15 82 OCCUPANCY BASIS NO. I CFM MIN. OF I PER CFM PEOPLEI PERSON (EXF) Total Total Total Total Total Total Total Total Total Total Total PROPOSED CONSTRUCTION ASSEMBLY ENV -3 NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 OMPONENT DESCRIPTION LAj B R -VALUE *HEAT ASSEMBLY NAME 6- Concrete Underground Slab Floor THICK- NESS (in.) CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) ASSEMBLY X Floor DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ TYPE (check one) Wall — W 0 IL 1 Ceiling / Roof 2.000 2.0001 yFRAMING MATERIAL None 2 Concrete, 140 Ib, Not Dried 0Z � 0.480 R FRAMING % % Framing % 14.00 3 15% (16" o.c. Wall) 4 12% (24" o.c. Wall) 10%(16" o.c. Floor/Coil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) CONSTRUCTION COMPONENTS LAj B R -VALUE *HEAT CAPACITY (Optional) THICK- NESS (in.) CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) SPECIFIC HEAT. (Btu/F-Ib) HC (A X B) (Btu/F-sf) DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 0.170 — — — 1 Earth 2.000 2.0001 85.00 0.20 17.00 2 Concrete, 140 Ib, Not Dried 6.000 0.480 70.00 0.20 14.00 3 4 5 6 7 8 9 'NOTE: INSIDE SURFACE AIR FILM — 0.920 — — — Weight and Specific Heat values for materials penetrated SUBTOT by wood 3.57 Rc framing include R the effects 155.0 TOTAL HC members. 31.0 of the framing 1 I Rc 1- (Fr%1100) 11 Rf Fr%1100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By EnergySoft User Number. 2366' Job Number. 521 Page:24 of 57 PROPOSED CONSTRUCTION ASSEMBLY ENV - PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 COMPONENT DESCRIPTION ASSEMBLY NAME 8^ Solid CMU WaIV1.5" Rigid A ASSEMBLY Floor R VALUE TYPE Wall (check one) 'HEAT LU WG W Ceiling / Roof THICK- NESS (in.) NFRAMING MATERIAL Metal WALL WEIGHT (lbslsf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) _ DESCRIPTION 0 Z FRAMING % 10% Framing % ❑ © ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 15°% (16" o.c. Wall) — 12%(24" o.c. Wall) — 1 10%(16" o.c. Floor/Ceil.) 8.000 0.600 SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) CONSTRUCTION COMPONENTS A B R VALUE 'HEAT CAPACITY (Optional) THICK- NESS (in.) CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbslsf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) _ DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ © ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 0.170 — — — 1 Conc Block, Normal Weight, Conc Filled 8.000 0.600 83.33 0.20 16.67 2 Insulation, Polystyrene, Molded Beads 1.500 5.775 0.12 0.29 0.04 3 Gypsum or Plaster Board 0.500 0.450 2.08 0.26 0.54 4 5 6 7 8 9 'NOTE: INSIDE SURFACE AIR FILM —1 0.680 Weight and Specific Heat values for materials penetrated SUSTOT by wood 7,67 85.5 TOTAL HC members. 17 2 Rc framing include R the effects of the framing [Q x ' Q] + L X 1 I Rc 1 - (Fr%1100) 1/ Rf Fr%/ 100 ASSEMBLY U -VALUE COMMENTS This assembly contains metal framing. The Assembly U -Value has been calculated using the ASHRAE/CEC Zonal Cavity Method. EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:25 of 57 PROPOSED CONSTRUCTION ASSEMBLY ENV- NAME NV- NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 COMPONENT DESCRIPTION A B R -VALUE *HEAT ASSEMBLY NAME Earth/Slab/S ancrete THICK- NESS (in.) CAVITY R VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) — SPECIFIC HEAT (Btu/F-Ib) ASSEMBLY Floor FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ — TYPE (check one) Wall — — 1 W 2.000 X Ceiling / Roof 2.000 85.00 0.20 usFRAMING MATERIAL yy� 5.500 0.440 0.440 Z 0.20 12.83 3 Spancrete,100 Ib p 1.700 FRAMING %o 10 �o Framing % 16.67 4 15% (16" o.c. Wall) 5 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) 6 SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Ceil.) ONSTRUCTION COMPONENTS A B R -VALUE *HEAT CAPACITY (Optional) THICK- NESS (in.) CAVITY R VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) — SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 0.170 0.170 — — 1 Earth 2.000 2.000 2.000 85.00 0.20 17.00 2 Concrete, 140 ib, Not Dried 5.500 0.440 0.440 64.17 0.20 12.83 3 Spancrete,100 Ib 10.000 1.700 1.700 83.33 0.20 16.67 4 5 6 7 8 9 'NOTE: INSIDE SURFACE AIR FILM — 0.6101 0.6101 4.92 1— — Weight and Specific Heat values for materials penetrated SUBTOTAL[.4.92 by wood Eii2.i TOTAL HC members: 46.5 RC framing include Rf the effects of the framing [ 0.2032 x 0.90 ] + [ 0.2032 x 0.10 1 / Rc 1 - (Fr%/ 100) 1 / Rf Fr%/ 100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:26 of 57 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE I 8/31/2005 COMPONENT DESCRIPTION DESCRIPTION AWING OUTSIDE SURFACE AIR FILM 1 Earth 2 Conc Block, Normal Weight, Conc Filled 3 insulation, PolyStyrene, Molded Beads 4 Gypsum or Plaster Board 5 ASSEMBLY NAME 12" CMU Underground Wall Furred 0.04 7 0.26 8 ASSEMBLY Floor INSIDE SURFACE AIR FILM TYPE (check one) XWall G LU Ceiling /Roof C N FRAMING MATERIAL Metal 42.6 p z FRAMING % 10% Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Coil.) SUBTOTAI R -VALUE DESCRIPTION AWING OUTSIDE SURFACE AIR FILM 1 Earth 2 Conc Block, Normal Weight, Conc Filled 3 insulation, PolyStyrene, Molded Beads 4 Gypsum or Plaster Board 5 0.12 6 0.04 7 0.26 8 9 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE THICK- NESS AWING ❑ ❑ ® ❑ El 1-1 El El 2.000 12.000 1.500 0.500 5.775 125.00 0.450 25.00 0.12 0.29 SUBTOTAI R -VALUE CAVITY R -VALUE (RC) WOOD FRAME R -VALUE 0.170 2.000 0.900 0.20 5.775 125.00 0.450 25.00 0.12 0.29 0.04 2.08 0.26 0.54 0.680 9.98 Kc M *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu*4b) HC (A X B) (Btu/F-sf) 85.00 0.20 17.00 125.00 0.20 25.00 0.12 0.29 0.04 2.08 0.26 0.54 212.2 TOTAL HC 42.6 •NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. r-1 1 / Rc 1 - (Fr%1100) 1 / Rf Fr%1100 ASSEMBLY U -VALUE This assembly contains metal framing. The Assembly U -Value has been calculated using the ASHRAE/CEC Zonal Cavity Method. I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:27 of 57 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE I 8/31/2005 -�] COMPONENT DESCRIPTION DESCRIPTION AMING OUTSIDE SURFACE AIR FILM 1 Conc Block, Normal Weight, Conc Filled 2 Insulation, PolyStyrene, Molded Beads 3 Gypsum or Plaster Board 4 0.29 ASSEMBLY NAME g" CMU Demisini Wall Furred 6 0.54 7 ASSEMBLY Floor 9 TYPE (check one) XWall 0 W Ceiling / Roof 5sFRAMING MATERIAL Metal 85.5 TOTAL HC 17 2 O FRAMING %o 10 �o Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10%(16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Coil.) SUBTOTAL R -VALUE DESCRIPTION AMING OUTSIDE SURFACE AIR FILM 1 Conc Block, Normal Weight, Conc Filled 2 Insulation, PolyStyrene, Molded Beads 3 Gypsum or Plaster Board 4 0.29 5 2.08 6 0.54 7 8 9 INSIDE SURFACE AIR FILM SUBTOTAL R -VALUE THICK- NESS (in.) AMING ❑ © ❑ El El El 8.000 1.500 0.500 0.20 0.450 0.12 0.29 0.04 2.08 0.26 SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.600 5.775 0.20 0.450 0.12 0.29 0.04 2.08 0.26 0.54 0.680 7.67 KG KT OAC 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F4b) HC (A X B) (Btu/F-sf) 83.33 0.20 16.67 0.12 0.29 0.04 2.08 0.26 0.54 85.5 TOTAL HC 17 2 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. 1 / Re 1 - (Fr%1100) 11 Rf Fr°%1100 ASSEMBLY U -VALUE This assembly contains metal framing. The Assembly U -Value has been calculated using the ASHRAE/CEC Zonal Cavity Method. I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:28 of 57 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 1 8/31/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Conc Block, Normal Weight, Conc Filled 2 Insulation, Mineral Fier, R-19 3 Gypsum or Plaster Board 4 0.37 5 ASSEMBLY NAME 8" Solid CMU Demising WaIVR-19 0.54 7 8 ASSEMBLY Floor 11 Rf Fr°A.1100 INSIDE SURFACE AIR FILM 0.680 TYPE (check one) Wall LU W 0 W Ceiling / Roof FRAMING MATERIAL yy 18.3 p ? FRAMING % 15 % Framing % 15%(16" o.c. Wall) 12% (24" o.c. Wall) 10%(16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Coil.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Conc Block, Normal Weight, Conc Filled 2 Insulation, Mineral Fier, R-19 3 Gypsum or Plaster Board 4 0.37 5 2.08 6 0.54 7 8 11 Rc 9 11 Rf Fr°A.1100 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.600 0.600 19.002 5.940 0.450 0.450 0.37 1.06 2.08 0.26 0.54 X 11 Rc 1 - (Fr%/ 100) 11 Rf Fr°A.1100 0.6801 0.680 20.90 7.84 KC Ki J LB *HEAT CAPACITY (Optional) WALL WEIGHT (ibWsf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. 83.33 0.20 16.67 2.87 0.37 1.06 2.08 0.26 0.54 X 11 Rc 1 - (Fr%/ 100) 11 Rf Fr°A.1100 ASSEMBLY U VALUE 88.31 TOTAL HC 18.3 •NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0478 X 0.85 ] + [ 0.12761 X 11 Rc 1 - (Fr%/ 100) 11 Rf Fr°A.1100 ASSEMBLY U VALUE I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:29 of 57 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE I 8/31/2005 COMPONENT DESCRIPTION A B. R -VALUE *HEAT ASSEMBLY NAME Slab/S ancrete THICK- NESS (in.) CAVITY R VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) ASSEMBLY Floor FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ — TYPE (check one) Wall — — G W Concrete, 140 ►b, Not Dried X Ceiling / Roof 0.4401 0.440 H N FRAMING MATERIAL Wood Spancrete,100lb 10.000 Q Z FRAMING % 10 % 16.67 3 Framing % 4 151/6 (16" o.c. Wall) 5 12%(24" o.c. Wall) 10%(16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Cell.) CONSTRUCTION COMPONENTS A B. R -VALUE *HEAT CAPACITY (Optional) THICK- NESS (in.) CAVITY R VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 0.170 0.170 — — — 1 Concrete, 140 ►b, Not Dried 5.500 0.4401 0.440 64.17 0.20 12.83 2 Spancrete,100lb 10.000 1.700 1.700 83.33 0.20 16.67 3 4 5 6 7 8 9 *NOTE: INSIDE SURFACE AIR FILM — 0.610 C 2.92 RC framing include 0.610 2.92 R the effects — — — Weight and Specific Heat values for materials penetrated SUBTOTAL by wood 147.5 TOTAL HC members. 2g 5 of the framing 1 / Rc 1 - (Fr%/ 100) 11 Rf Fr%1100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 521 Page:30 of 57 "ROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE ___]_8/31/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Earth 2 Conc Block, Normal Weight, Conc Filled 3 Insulation, PolyStyrene, Molded Beads 4 Gypsum or Plaster Board 5 ASSEMBLY NAME 8• CMU UndgWround Wall Furred 0.04 7 0.26 8 ASSEMBLY Floor INSIDE SURFACE AIR FILM TYPE (check one) wall G W Ceiling / Roof G W FRAMING MATERIAL Metal 34.2 p Z FRAMING %o 10 �o °k Framing 15%(16" O.C. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) I SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Earth 2 Conc Block, Normal Weight, Conc Filled 3 Insulation, PolyStyrene, Molded Beads 4 Gypsum or Plaster Board 5 0.12 6 0.04 7 0.26 8 9 INSIDE SURFACE AIR FILM I SUBTOTAI R -VALUE CAVITY R VALUE (RQ WOOD FRAME R -VALUE 0.170 2.000 0.600 0.20 5.775 83.33 0.450 16.67 0.12 0.29 0.04 2.08 0.26 0.54 0.680 9.68 Mr M -HEAT CAPACITY (Optional) WALL WEIGHT (Ibs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sl) 85.00 0.20 17.00 83.33 0.20 16.67 0.12 0.29 0.04 2.08 0.26 0.54 170.5 TOTAL HC 34.2 •NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. L� 1 I Rc 1 - (Fr%/100) 1 I Rf Fr*/6 1100 ASSEMBLY U VALUE This assembly contains metal framing. The Assembly U -Value has been calculated using the ASHRAE/CEC Zonal Cavity Method. EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:31 of 57 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 pWood 4 Insulation, Mineral Fiber, R-38 s ASSEMBLY NAME ITile Roof/R-38 0.41 7 0.361 1.39 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.610 39.67113.06 TYPE (check one) Wall LULU X Ceiling / Roof � C y FRAMING MATERIAL Wood ? p FRAMING % 10 Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Ceil.) SUBTOTAI R VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 pWood 4 Insulation, Mineral Fiber, R-38 s 1.42 6 0.41 7 0.361 1.39 L98 INSIDE SURFACE AIR FILM SUBTOTAI R VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.210 0.210 0.060 0.060 0.620 0.620 38.0001 11.385 1.42 0.29 0.41 3.86 0.361 1.39 0.6101 0.610 39.67113.06 rcc Kr *HEAT CAPACITY (Optional) WALL WEIGHT (Ibs/sf) SPECIFIC HEAT (BWIF4b) HC (A X B) (Btu/F-sf) [ 0.0252 x 0.90 ] 2.50 0.24 0.60 0.06 0.35 0.02 1.42 0.29 0.41 3.86 0.361 1.39 7 8 TOTAL HC 2 4 •NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0252 x 0.90 ] + F-10.0766 X 1 I Rc 1-(Fr%1100) 11 Rf Fr%1100 ASSEMBLY U -VALUE L__ EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Pane:32 of 57 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 COMPONENT DESCRIPTION A B ASSEMBLY NAME Ca et/5.5" Conc/10" Spancrete -HEAT ASSEMBLY X Floor THICK- NESS (in.) CAVITY R -VALUE (Rc) TYPE (check one) Wall SPECIFIC HEAT (Btu/F-Ib) Lu W Ceiling / Roof OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ NFRAMING MATERIAL None — 64.17 ? — 1 O FRAMING % % Framing 0.20 12.83 2 15%(16" o.c. Wall) 10.000 1.700 12% (24" o.c. Wall) 0.20 16.67 s 10%(16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 2.080 7% (24" o.c. Floor/Coil.) CONSTRUCTION COMPONENTS A B R -VALUE -HEAT CAPACITY (OpUonal) THICK- NESS (in.) CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sq DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 0.170 — 64.17 — — 1 Concrete, 140 1b, Not Dried 5.500 0.440 0.20 12.83 2 Spancrete, 1001b 10.000 1.700 83.33 0.20 16.67 s Flooring, Carpet and Fibrous Pad 0.250 2.080 0.08 0.34 0.03 4 5 6 7 8 9 'NOTE: INSIDE SURFACE AIR FILM —1 0.920 — — — Wei ht and Specific Heat values for materials penetrated SUBTOTA by wood 5.31 147.6 TOTAL HC members. 29.5 Rc framing include R the effects of the framing [� x + [� x ��] = 0.188 1 / Rc 1 - (Fr%1100) 11 Rf Fr0/6 1100 ASSEMBLY U -VALUE COMMENTS EnergyPm 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:33 of 57 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE I 8/31/2005 COMPONENT DESCRIPTION DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 Roofing, Built -Up 2 plywood 3 Insulation, Mineral Fiber, R-38 4 0.29 5 ASSEMBLY NAME IBIU Roof/R-38 1.39 7 8 1 / Rc ASSEMBLY Floor Fr%/ 100 INSIDE SURFACE AIR FILM 0.610 39.73 TYPE (check one) Wall 0 W X Ceiling / Roof NFRAMING MATERIAL yy p Z FRAMING %o 10 �o °,6 Framing 15% (16" o.c. Wall) 1296 (24" o.c. Wall) 10%(16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Coil.) SUBTOTAI R -VALUE DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 Roofing, Built -Up 2 plywood 3 Insulation, Mineral Fiber, R-38 4 0.29 5 3.86 6 1.39 7 8 1 / Rc 9 11 Rf Fr%/ 100 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE THICK- NESS (in.) 4MING ❑ ❑ ® El El El 0.170 0.375 0.500 1.500 0.620 38.000 11.385 0.29 0.41 3.86 0.36 SUBTOTAI R -VALUE CAVITY R -VALUE (RC) WOOD FRAME R -VALUE 0.170 0.170 0.3301 0.330 0.620 0.620 38.000 11.385 0.29 0.41 3.86 0.36 1.39 X 1 / Rc 1 - (Fr%/ 100) 11 Rf Fr%/ 100 0.6101 0.610 39.73 13.11 RG Rr *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (BW -1b) HC (A X B) (Btu/F-sf) members. 2.19 0.35 0.77 1.42 0.29 0.41 3.86 0.36 1.39 X 1 / Rc 1 - (Fr%/ 100) 11 Rf Fr%/ 100 ASSEMBLY U -VALUE 7 5 TOTAL HC 2 6 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0252 X 0.90 ] + [ 0.0762 X 1 / Rc 1 - (Fr%/ 100) 11 Rf Fr%/ 100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:34 of 57 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE HIDEAWAY CLUBHOUSE I 8/31/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-13 4 Gypsum or Plaster Board 5 ASSEMBLY NAME R-13 Demising Wall to Uncondifioned 0.62 7 0.26 6 ASSEMBLY Floor 11 Rf Fr%/ 100 INSIDE SURFACE AIR FILM 0.680 TYPE (check one) Wall LU G LU Ceiling /Roof G 0 FRAMING MATERIAL yy 2 0 p Z FRAMING % 15 % o Framing � 15%(16" o.c. Wall) 12% (24" o.c. Wall) 10%(16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) THICK- NESS kMING (in.) ❑ 0.625 ❑ 0.010 ® 3.500 ❑ 0.625 El El El El El SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-13 4 Gypsum or Plaster Board 5 1.68 6 0.62 7 0.26 6 11 Rc 9 11 Rf Fr%/ 100 INSIDE SURFACE AIR FILM THICK- NESS kMING (in.) ❑ 0.625 ❑ 0.010 ® 3.500 ❑ 0.625 El El El El El SUBTOTAI R -VALUE CAVITY R VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 0.060 0.060 12.999 3.465 0.562 0.562 1.68 0.37 0.62 2.60 0.26 0.68 11 Rc 1 - (Fr%/ 100) 11 Rf Fr%/ 100 0.6801 0.680 1 15.031 f.50 KC KT 0IIIIIIIIIIIIIIIE *HEAT CAPACITY (Optional) WALL WEIGHT (Ibs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. 2.60 0.26 0.68 0.06 0.35 0.02 1.68 0.37 0.62 2.60 0.26 0.68 11 Rc 1 - (Fr%/ 100) 11 Rf Fr%/ 100 ASSEMBLY U -VALUE 6.9 TOTAL HC 2 0 •NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0665 0.85 ] + I—,X 0.1818 X 0.15 ] = 0.084 11 Rc 1 - (Fr%/ 100) 11 Rf Fr%/ 100 ASSEMBLY U -VALUE L EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Paoe:35 of 57 1 ENVELOPE MANDATORY MEASURES ENV -MM NAME HIDEAWAY CLU DATE 8/31 DESCRIPTION Desi ner Enforcement §118(,) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. X] § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. X❑ § 117(a) All Exterior Joints and openings Ih the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). 0 § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. R §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have Insulation with an Installed R -value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521. Page:36 of 57 MECHANICAL MANDATORY MEASURES Patti of 2 MECH-MM Q HIDEAWAY CLUBHOUSE DATE 8/31/2 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies 0 §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. F] § 115(a) Fan type central furnaces shall not have a pilot light NXI § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. X] § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: a§ 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)113 An occupancy sensor to control the operating period of the system; or ❑ § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the System. X❑ $122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint F§ 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with Isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off Independently of other Isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. 0 § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. $112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3A By EnergySoft User Number. 2366 Job Number. 521 Page:37 of 57 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 Description Designer Enforcement Ventilation FX§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ❑ § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)l Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or ❑ § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or R§ 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or El § 121 (f)4 Another method approved by the Commission. Service Water Heating Systems X❑ § 113(b)2 if a circulating hot water system is Installed, it stall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. R § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. X] § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallonsicycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPm 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:38 of 57 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA AC -1 73 (Number of Systems 1 11 Heating System Output per System 21,200 Total Output (Btuh) 21,200 Output (Btuh/sgft) 290.4 Cooling System Output per System 24,200 Total Output (Btuh) 24,200 Total Output (Tons) 2.0 Total Output (Btuh/sq(t) 331.5 Total Output (sgft/ron) 36.2 CFM per System 800 Airflow (0m) 800 Airflow (cfm/sgft) 10.96 Airflow (cfm/Ton) 396.7 Outside Air (%) 1.4 Outside Air (cfm/sgft) 0.15 Note: values above given at AW conditions 26.0 OF 69.4 OF Outside Air 11 drn Supply Fan 800 cfm 70.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 332 6,525 146 70 2,990 0 112.0/77.70F 74.6/61.6OF 74.6/61.6OF 65 30 0 0 1 445 206 11 516 0 0 65 30 7 10 352 3 566 LENNOX HS29-024-'P' 16,314 4,032 0 Total Adjusted System Output 16,314 x,032 (Adjusted for Peak Design Conditions) 1 F777A TIME OF SYSTEM PEAK Aug3 pm Jan 12 am earn Temperatures at Time of Heatina Peak) 69.4oF . 110.OoF Heating Coag f% Retum Air Ducts `S Supply Air Ducts 110.OoF ROOMS 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.70F 74.6/61.6OF 74.6/61.6OF 55.6/54.4OF Supply Air Ducts Outside Air 11 cfm Supply Fan Coding Coil 55.7 / 54.5 of 800 cfm ROOMS 48.7% R.H. of 74.0/61.3OF 74.1/61.4 Retum Air Ducts EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:39 of 57 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 1A & 1 B 4,920 Number of Systems 2 Heating System Output per System 85,000 Total Output (Btuh) 170,000 Output (Btuh/sgft) 34.6 Cooling System Output per System 94,500 Total Output (Btuh) 189,000 Total Output (Tons) 15.8 Total Output (Btuh/sgfl) 38.4 Total Output (sgWon) 312.4 Air System CFM per System 2,900 Airflow (cfm) 5,800 Airflow (cf nisgft) 1.18 Airflow (cf nrron) 368.3 Outside Air (%) 16.1 Outside Air (cfrnlsgft) 0.19 Note: values above Given at ARI conditions 26.0 OF —1 Outside 934 cfm 69.1 °F LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent 1. CFM I Sensible 5,97 114,368 18,64 6,828 78,073 0 1,144 781 0 0 934 34,398 12,376 934 43,129 0 0 1,144 781 151,0541 31 016 122 764 LENNOX HP29-090 153,230 19,133 111,805 Total Adjusted System Output153,230 19,133 111,805 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK FJul 2 pm an 12 am KICS (Airstream Temperatures at 62.1°F. 80.10F Heating Coil -Q*-J Supply Fan 5800 cfrn 80.10F -)o Supply Air Ducts 80.0 OF ROOMS 69.2 OF 1% Retum Air Ducts 4 COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.4°F 82.2/66.3°F 57.5/56.2°F 57.5/56.2°F • Supply Air Ducts Outside Air 934 cfrn Cooling Cal Supply Fan 57.7 / 56.2 OF 5800 cfm 50.8° R.H. ROOMS 76.6/64.0 o F 76.5 0 / 64.0 F K Retum Air Ducts M EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:40 of 57 1 1HVAG SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 2 782 NGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 34,400 Total Output (Btuh) 34,400 Output (Btuhfsgft) 44.0 Cooling System Output per System 35,400 Total Output (Btuh) 35,400 Total Output (Tons) 3.0 Total Output (Stuhlsgft) 45.3 Total Output (sgftfTon) 265.1 Air System CFM per System 1,100 Airflow (cfm) 1,100 Airflow (cfmfsgft) 1.41 Airflow (cf n ron) 372.9 Outside Air (0/6) 17.8 Outside Air (cf nisgft) 0.25 Note: values above given at AN conditions 26.0°F 62.2°F Outside Air 196 cfm Q!0fJ Supply Fan 1100 cfm 70.0 °F 12.0 / 77.7 OF 0 Outside 196 cfm 74.1/65.6 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensiblel Latent CFM I Sensible 1,159 16,386 5,16 268 3,250 0 164 32 0 0 196 7,935 1,03 196 9,216 0 0 164 32 24,6501 6.1921 12 531 LENNOX HP29-036-'P 23,813 9,119 22,624 Total Adjusted System Output23,813 9,119 22,62a (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Jul 3 pm Jan 12 am 62.2°F . 81.30F Heating Cal �% Retum Air Ducts 4 80.9/67.9°F 80.9/67.8°F 60.7/59.5°F -- us J - Supply Fan 1100 cfm Coding Cal k Retum Air Ducts 4 Supply Air Ducts 81.3 OF ROOMS 70.0 °F Supply Air Ducts 60.8/59.6OF 64.1% R.H. ROOMS 74.0/65.5°F I EnemvPro 3.1 By EnemvScft User Number. 2366 Job Number. 521 Paae:41 of 57 1 IHVAC-SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 3A 1,065 Number of Systems 1 Heating System Output per System 43,500 Total Output (Btuh) 43,500 Output (Btuhlsgft) 40.8 Cooling System Output per System 44,000 Total Output (Btuh) 44,000 Total Output (Tons) 3.7 Total Output (i3tuh/sgft) 41.3 Total Output (sgft/Ton) 290.5 Air System CFM per System 1,500 Airflow (cfm) 1,500 Airflow (cfm/sgft) 1.41 Alrflow (cim/Ton) 409.1 Outside Air (%) 10.7 Outside Air (cfm/sgft) 0.15 Note: values above given at ARI conditions 26.0 OF 65.2 OF Outside Air e 160 cfm Supply Fan 1500 cfm 69.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 2,136 30,491 2,130 658 20,303 0 305 203 0 0 160 6,301 1,402 160 7,514 0 0 305 203 37,4081 3:5321 28 223 LENNOX HP29-04VP 28,332 11,601 28,609 7.5 kW Supplemental Electric 25,598 Total Adjusted System Output 28,332 11,601 54,206 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 2 pm Jan 12 am RICS (Airstream Temperatures at Time 65.20F ■ 83.OoF ■ 98.9oF Heating Cail Aux. Heat Coil 11.0/77.4OF 78.1 /66.1OF Outside Air 160 Cfm Supply Far 1500 cfm 74.2/64.5 of �% Retum Air Ducts M 78.1 / 66.0 of IIIII 60.5/59.40F Cooling Cal f% Retum Air Ducts `i Supply Air Ducts 98.8 of ROOMS 70.0 of Supply Air Ducts 60.7/59.5OF 60.2% R.H. ROOMS 74.0/64.5OF EnemyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:42 of 57 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 3B 1.488 Number of Systems 1 Heating System Output per System 55,000 Total Output (Btuh) 55,000 Output (Btuh/sgft) 37.0 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 39.0 Total Output (sgft/Ton) 307.9 Air System CFM per System 1,900 Airflow (cfm) 1,900 Airflow (cfrrtlsgft) 1.28 Airflow (cfm/Ton) 393.1 Outside Air (%) 15.1 Outside Air (cfm/sgft) 0.19 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROME 26.0°F 63.3°F Outside Air 286 elm Supply Fan 1900 cfm 69.9 OF 12.0 / 77.7 OF —1� Outside Air 286 cfm 74.1 / 67.3 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 1,904 23,180 12,152 Li2T 14,851 0 232 149 0 0 286 11,635 -20 286 13,490 0 0 232 149 35,2781 11 95 28 638 LENNOX HP29-06VP 35,227 19,695 36,172 Total Adjusted System Output 35,227 19,695 36,172 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 3 pm I I Jan 12 am RICS (Airstream Tel 63.3°F ■ 81.10F Heating Coil �% Retum Air Ducts 4 at Time 79.8/68.9°F79.8/68.9°F W 62.5/61.60F Supply Fan 1900 cfm Cooling Coil h Return Air Ducts `S Supply Air Ducts 81.0 OF ROOMS 70.0 °F Supply Air Ducts 62.6 / 61.6 of 70.9% R.H. ROOMS 74.0/67.2°F EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:43 of 57 1 IRVAC-SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 4 & 5 2 625 Number of Systems 2 Heating System Output per System 85,000 Total Output (Btuh) 170,000 Output(Btuh/sgft) 64.8 Cooling System Output per System 94,500 Total Output (Btuh) 189,000 Total Output (Tons) 15.8 taltutp(Btuh/sqft) PE 72.0 otal (sqf rron) 166.7 Air System CFM per System 2,900 Airflow (chn) 5,800 Airflow (cfrn/sgft) 2.21 Airflow (cfm/Ton) 368.3 Outside Air (%) 6.8 Outside Air (cfndsgft) 0.15 Note: values above given at ARI conditions 26.0 OF outside Air — 1 394 cfm 70.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 2,086 40,804 45,938 1,477 23,621 0 408 236 0 0 394 16,013 4,068 394 18,558 0 0 408 236 57,634T 50:0051 42 651 LENNOX HP29-090 130,267 37,635 111,805 Total Adjusted System Output 130,267 37,635 111,805 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F7 Jul 3 Prn Jan 12 am ream Temueratures at Time of Heatina Peak) 67.OoF - 8 Heating Cod -Q, SY Supply Fan 5800 Orn 85.0 of -� Supply Air Ducts 84.9 of ROOMS 70.0 of Retum Air Ducts `SIt OOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112.0/77.7OF 76.6/65.OoF 55.7/54.80F 55.7/54.8OF ® Supply Air Ducts Outside Air 394 cfmF Cooling Coil Supply Fan 55.8 /54.8 5800 cfm 58.4% R.H. ROOMS 74.1/64.0 ° F 74.0 ! 64.0 of Retum Air Ducts ' EnemvPro 3.1 By EnerovSoft User Number. 2366 Job Number. 521 Page:44 of 57 1HVAG SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 6 1,368 NGINFERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 55,000 Total Output (Btuh) 55,000 Output (Btuh/sgft) 40.2 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 42.4 Total Output (sgft/Ton) 283.0 Air System CFM per System 1,900 Airflow (cfm) 1,900 Airflow (cfrrdsgft) 1.39 Airflow (cfm/ron) 393.1 Outside Air (0/,) 17.3 Outside Air (cfrnisgft) 0.24 Note: values above given at ARI conditions 26.0 OF 62.3 OF Outside Air 328 cfm Supply Fan 1900 cfm 69.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 3,640 45,002 8,399 2,422 25,765 0 450 258 0 0 328 13,297 748 328 15,442 0 0 450 258 59,199 9,1471 41722 LENNOX HP29-060-'P 37,688 16,853 36,172 Total Adjusted System Output 37,688 16,853 36,172 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm F Jan 12 am Cream Temaeratures at Time of Heatina Peak) . 62.3 OF ■ 80.10F Heating Cot? 770 oefii. Air f'17*� Supply Air Ducts 79.9 of ROOMS 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.70F 80.7/68.5OF 80.7/68.4OF 62.2/61.2OF Q Supply Air Ducts Outside Air 328 cfrn Supply Fan Cooling Coil 62.5 / 61.2 of 1900 cfm 67.5% R.H. ROOMS 74.2/66.4 of 74.0 66.4 of 3.1 User Number. 2366 Retum Air Ducts Job Number. 521 of 57 114VAC-SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 7 1,925 Number of Systems 1 Heating System Output per System 85,000 Total Output (Btuh) 85,000 Output (Btuh/sgft) 44.2 Cooling System Output per System 94,500 Total Output (Btuh) 94,500 Total Output (Tons) 7.9 Total Output (Btuh/sgft) 49.1 Total Output (sgft/Ton) 244A Air System CFM per System 2,900 Airflow (cfin) 2,900 Airflow (cfm/sgft) 1.51 Airflow (cfm/Ton) 368.3 Outside Air (%) 28.1 Outside Air (cfm/sgft) 0.42 Note: values above given at ARI conditions WnNG SYSTEM PSYC 26.0 OF Outside Air 814 cfm 70.0 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 4,152 50,917 28,520 2,144 12,765 0 509 128 0 0 814 33,037 -2,510 814 38,383 0 0 509 128 1 84,972 26,010 51403 LENNOX HP29-090 69,619 22,641 55,902 Total Adjusted System Output 69,619 22,641 55,90 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 3 pm Jan 12 am RICS (Airstream Temperatures at 57.6°F 75.6°F Heating Coil (I!f Supply Fan 2900 cfnn 75.6 OF Supply Air Ducts 75.6 OF ROOMS 70.0 OF }% Retum Air Ducts `i DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.70F 84.8/70.7°F 62.4/61.2°F 62.4/61.2°F ® Supply Air Ducts Outside Air 814 cfm Cooling Cal Supply Fan 62.6 / 61.2 OF 2900 cfm 73.6% R.H. ROOMS 74.2/67.9 °F 74.0/67.9°F � k Retum Air Ducts M EnerovPro 3.1 By EnerpvSoft User Number. 2366 Job Number. 521 Page:46 of 57 1HVAG SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 8A & 8B 3 226 Number of Systems 2 Heating System Output per System 55,000 Total Output (Stuh) 110,000 Output (Btuh/sgft) 34.1 Cooling System Output per System 58,000 Total Output (Btuh) 116,000 Total Output (Tons) 9.7 Total Output (Stuh/sgft) 36.0 Total Output (sgft/Ton) 333.7 Air System CFM per System 1,900 Airflow (cf n) 3,800 Airflow (cfrnfsgft) 1.18 Airflow (cfm/ron) 393.1 Outside Air (%) 12.7 Outside Air (cfmfsgft) 0.15 Note: values above given at AN conditions 26.0 OF 64.4 OF Outside Air 484 dm Supply Fan 3800 cfn► 70.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 3,728 40,380 40,938 LI2E 16,146 0 404 161 0 0 484 19,133 -4,139 L484 22,806 0 0 404 161 60,3201 3677981 39 275 LENNOX HP29-OWP 61,105 52,235 72,344 Total Adjusted System Output 61,105 52,235 72,344 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug2 pm Jan 12 am 64.4 OF 82.10F Heating Coil Retum Air Ducts 11.0/77.4OF 78.8/70.5OF Outside Air 484 cfm Supply Fat 3800 ch 74.1/69.4 ° F 78.8/70.40F 11111111 63.8/63.10F Cooling Coil K Return Air Ducts `i Supply Air Ducts 82.1 OF ROOMS 70.0 OF Supply Air Ducts 63.9/63.1OF 79.7"x6 R.H. ROOMS 74.0/69.4OF I EnerovPro 3.1 By EnemvSoft User Number. 2366 Job Number. 521 Page:47 of 57 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 9 360 Number of Systems 77E1 I COIL HTG. PEAK Heating System Output per System 21,200 Total Output (Stuh) 21,200 Output (Btuh/sgft) 58.9 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 66.7 Total Output (sclWTon) 180.0 Air System CFM per System 765 Airflow (cfm) 765 Airflow (cf n1sgft) 2.12 Airflow (cfm/ron) 382.5 Outside Air (%) 7.1 Outside Air (cfrn/sgft) 0.15 Note: values above given at AW conditions 26.0°F 66.40F Outside Air 54 cfm ) ( (F Supply Fan 765 cfm 69.5 °F 66.4 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent I CFM Sensible 61 11,069 720 364 13,162 0 332 395 0 0 54 2,176 882 54 2,519 0 0 332 395 13,9101 1.6021 16 471 LENNOX HP29-024-'P 16,692 4,100 13,943 5.0 kW Supplemental Electric 17,065 Total Adjusted System Output 16,692 a,1o0 31,008 (Adjusted for Peak Design Conditia�s) TIME OF SYSTEM PEAK Jul 3 m Jan 12 am eam Temperatures at Time of Heating Peak) 83.4 of to 104.3 OF Heating Coil Aux Heat Coil k Retum Air Ducts `i Supply Air Ducts 4 103.8 OF ROOMS 70.0 °F I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.70F 77.1 / 63.5 OF 77.1 / 63.4 OF 56.7 / 55.5 OF ® Supply Air Ducts Outside Air 54 cfm Supply Fan Coding Coil 57.1 / 55.7 OF 765 cfm 51.6% R.H. ROOMS 74.4/62.3°F 74.0 I /62.1°F 3.1 User Number. 2366 Retum Air Ducts Job Number. 521 of 57 4VAC'SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 10 8r 13 4,881 Number of Systems 1 2 Heating System Output per System 85,000 Total Output (Btuh) 170,000 Output (Btuhfsgft) 1 34.8 Cooling System Output per System 94,500 Total Output (Stuh) 189,000 Total Output (Tons) 15.8 Total Output (Btuh/sgft) 38.7 Total Output (sqf rTon) 309.9 Air System CFM per System 2,900 Airflow (cf n) 5,800 Airflow (cfmfsgft) 1.19 Airflow (cfm/Ton) 368.3 Outside Air (0/6) 12.6 Outside Air (cfrn/sgft) 0.15 Note: values above alven at ARI conditions 26.0 OF Outside Air 732 cfm 69.9 of TOOLING SYSTEM 12.0 / 77.7 of 311 ;0 Outside Air 732 cfrn 74.3/65.8 of EnerovPro 3.1 B1 64.4 ° F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensiblei Latent CFM I Sensible 3,998 65,433 52,775 1,532 20,111 0 1,963 603 0 0 732 29,579 3,298 732 34,460 0 0 1,963 603 98,9467F77;" 55 778 LENNOX HP29-090 128,433 46,189 111,805 Total Adjusted System Output 128,433 46,189 111,805 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 m I Jan 12 am Heating Cad 82.3 of _Q8 -f Supply Fan 5800 cfm 82.3 of —� Supply Air Ducts 82.2 OF ROOMS 70.0 OF �% Return Air Ducts M 79.1/67.401 58.4 / 57.5 °F --i Supply Fan 5800 cfm User Number. 2366 Gaoling Cal 58.4/57.50F Supply Air Ducts tj —if 58.7/57.6OF 65.0% R.H. ROOM) 74.0/65.7OF k Retum Air Ducts M Job Number. 521 of 57 114VAG SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 11 1840 Number of Systems 1 Heating System Output per System 85,000 Total Output (Btuh) 85,000 Output (Stuh/sgft) 46.2 Cooling System Output per System 94,500 Total Output (Btuh) 94,500 Total Output (Tons) 7.9 Total Output (Btuh/sgft) 51.4 Total Output (sqf rron) 233.7 Air System CFM per System 2,900 Airflow (cfm) 2,900 Airflow (cf /sgft) 1.58 Airflow (cfm/Ton) 368.3 Outside Air (°/6) 19.0 Outside Air (cfm/sgft) 0.30 Note: values above alven at ARI conditions 26.0 OF Outside�11 552 cfm 69.8 °F LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 2,842 46,539 14,337 2,018 20,029 0 1,396 601 0 0 552 22,214 5,376 552 25,915 0 0 1,396 601 71,545 19,713 47 146 LENNOX HP29-090 72,489 14,278 55,902 Total Adjusted System Output 72 489 14,278 55,902 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am seam Temperatures at Time of Heatina Peak) 61.5°F ■ 79.50F Heating Coil u Supply Fan 2900 cfnt 79.5 OF —30 Supply Air Ducts 79.3 OF ROOMS 70.0 OF k Return Air Ducts `i DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.7°F 81.6/67.0°F 58.3/57.0°F 58.3/57.0°F © Supply Air Ducts Outside Air I ( P 552 cfm Cooling Coil Supply Fan 58.7 / 57.2 OF 2900 cfm 59.1% R.H. ROOMS 74.4/64.3°F 74.0/64.2°F 1% Retum Air Ducts i EnerayPro 3.1 BY EnergySoft User Number. 2366 Job Number. 521 Page:50 of 57 1 INVAC' SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME HIDEAWAY CLUBHOUSE DATE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 11A 627 Number of Systems 1 Heating System Output per System 55,000 Total Output (Btuh) 55,000 Output (Btuh/sgft) 87.7 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 92.5 Total Output (sgft/Ton) 129:7 Air System CFM per System 1,900 Airflow (chn) 1,900 Airflow (cfnisgft) 3.03 Airflow (cfmrron) 393.1 Outside Air (%) 16.5 Outside Air (cfrnlsgft) 0.50 Note: values above riven at ARI conditions 26.0°F 62.6 OF Outside Air 314 cfm Supply Fan 1900 cfm 69.8 of 62.6 ° F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,665 30,531 11,552 LLF29 13,360 0 916 401 0 0 314 12,620 -28 314 14,722 0 0 916 401 44,995 11,27 28 883 LENNOX HP29-06VP 36,227 18,949 36,172 Total Adjusted System Output 36,227 18,949 36,172 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3m Jan 12 am Healing Coil 12.0/77.70F 80.6/69.2OF Outside Air 314 cfm Supply Fan 1900 cfm 74.5/67.4 of 80.3 of 1% Return Air Ducts 4 80.6/69.10F M 62.9/61.80F Cooling Cal >% Retum Air Ducts `i Supply Air Ducts 80.1 of ROOMS 70.0 of Supply Air Ducts 63.3/62.0 OF 71.1% R.H. ROOMS 74.0/67.3OF EnemyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:51 of 57 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 12A/12B 2,262 NGINEERING CHECKS 11SYSTEM LOAD INumber of Svstems 1 21 Output per System 85,000 Total Output (Stuh) 170,000 Outout I8tuh/saft) 75.2 Cooling System Output per System 94,500 Total Output (Btuh) 189,000 Total Output (Tons) 15.8 Total Output (Btuh/sgft) 83.6 Total Output (sgWTon) 143.6 Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfmlTon) Outside Air (%) Outside Air (cfm/sgfl) Note: values above elven at ARI conditions 26.0 OF Outside Air 1034 cfm 69.9 of 12.0 / 77.7 of Outside Air 1034 cfm 74.4/65.0 of 62.1 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM FSensible 4,872 78,487 37,282 1,824 19,482 0 2,355 584 0 0 1,034 41,719 7,709 1,034 48,690 0 0 2,355 584 124 934 44 992 1 69,341 ,VUU ,800 LENNOX HP29-090 139,878 34,672 111,805 2.56 68.3 Total Adjusted System Output r�� 17.8 (Adjusted for Peak Design Conditions) 139,878 34,672 111,805 0.46 TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Heating Coil V Supply Fan 5800 cfm 80.10F -� Supply Air Ducts 80.0 of ROOMS 70.0 of �% Return Air Ducts 4 81.1 /67.4OF 58.6/57.4OF s Ir' Supply Fan 5800 cfm Cooling Coil 58.6/57.4OF Supply Air Ducts 59.0/57.6OF 61.7% R.H. ROOMS 74.0/64.9OF h Retum Air Ducts N I EnerovPro 3.1 By EneravSoft User Number. 2366 Job Number. 521 Page:52 of 57 1 1HV'AC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 14 1.378 Number of Systems 1 Heating System Output per System 120,000 Total Output (Btuh) 120,000 Output (Btuh1sgft) 87.1 Cooling System Output per System 124,500 Total Output (Btuh) 124,500 Total Output (Tons) 10.4 Total Output (Btuh/sgft) 90.3 Total Output (sgft/ron) 132.8 Air System CFM per System 3,800 Airflow (cfrtl) 3,800 Airflow (cf rdsgft) 2.76 Airflow (cf n ron) 366.3 Outside Air (%) 18,1 Outside Air (cf n/sgft) 0.50 ote: values above given at ARI conditions ATING SYSTEM PSYCHROMETRICS 26.0 OF 61.9 OF Outside Air 689 cfm 69.8 of 12.0 / 77.7 OF 0 Outside 689 cfm 74.4/65.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 3,663 56,751 25,390 2,053 24,363 0 1,703 731 0 0 689 27,761 4,266 689 32,369 0 0 1,703 731 87,9171 29.6561 58 194 LENNOX HP29-120 90,047 25,583 78,921 Total Adjusted System Output g0 047 25,583 78,921 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am yam Temperatures at Time of Heatina Peak► Heating Cao 81.2 OF IUD Supply Fan 3800 cfm 81.2/67.70F 81.2 of —�! Supply Air Ducts 81.1oF ROOMS 70.0 of o,.a.._. A:_ n..—_ natures at Time o 59.1 / 58.0 of Cooling Cal Supply Fan 3800 cfm 59.1 / 58.0 of Supply Air Ducts 59.5/58.1OF 63.1% R.H. ROOMS 74.0/65.2OF h Return Air Ducts `i I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:53 of 57 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 15 1,697 Number of Systems 1 Heating System Output per System 120,000 Total Output (Btuh) 120,000 Output (Btuhlsgft) 73.8 Cooling System Output per System 124,500 Total Output (Btuh) 124,500 Total Output (Tons) 10.4 Total Output (Btuh/sgft) 76.5 Total Output (sgftrron) 156,8 Air System CFM per System 3,800 Airflow (cfm) 3,800 Airflow (cfmrsgft) 2.34 Airflow (cfrnrron) 366.3 Outside Air Outside Air (cfrNsgft). 0.50 Note: values above alven at ARI conditions 26.0 OF _ Outside Air 814 cfm 69.9 OF 112.0 / 77.7 OF 310� Outside Air 814 cfm 74.4/66.5 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG.PEAK CFM Sensible Latent CFM Sensible 3,524 49,432 29,977 759 8,018 0 1,483 241 0 0 814 32,793 1,947 814 38,323 0 1 0 1,4831 241 85,4751 31,925 46 821 LENNOX HP29-120 89,347 28,683 78,921 Total Adjusted System Output 89 347 28,683 78,921 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F7 Jul 3 pm Jan 12 am mm Temperatures at Time of Heating Peaki 60.5°F ■ 79.9°F Heating Coil __Q1*J Supply Fan 3800 cfm 79.9 OF 30 Supply Air Ducts 79.8 OF ROOMS 70.0 OF o,....._. A:_ r,.._._ 1 82.4 / 68.9 OF 60.5 / 59.4 OF 60.5 / 59.4 OF Supply Air Ducts Coding Coil Supply Fan 60.9 / 59.5 OF 3800 cfm 67.4% R.H. ROOMS 74.0/66.3°F EneMyPro 3.1 By EnergySaft User Number. 2366 Job Number. 521 Page:54 of 57 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA SPLIT HEAT PUMP 15A 914 Number of Systems 1 Heating System Output per System 85,000 Total Output (Btuh) 85,000 Output (Btuh/sgft) 93.0 Cooling System Output per System 94,500 Total Output (Btuh) 94,500 Total Output (Tons) 7.9 Total Output (Btuh/sgft) 103.4 Total Output (sgftrron) 116.1 Air System CFM per System 2,900 Airflow (cfm) 2,900 Airflow (cf n1sgft) 3.17 Airflow (cfm/Ton) 368.3 Outside Air (%) 15.8 Outside Air (cfndsgft) 0.50 Note: values above elven at ARI conditions 26.0 OF 0 Outside 457 cfm 69.9 of 11.0 / 77.4 of 0 Outside 457 cfm 74.5/64.20F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,62 45,111 16,840 1,248 14,440 0 1,353 433 0 0 457 17,897 4,589 457 21,489 0 1 0 1,3531 433 65,81 21 430 36 795 LENNOX HP29-090 70,604 15,802 55,902 Total Adjusted System Output 70,604 15,802 55,902 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Temperatures at 62.9 OF . 80.9 OF Heating Coil PSYCHROMETRICS -Q9J Supply Fan 2900 cfm 80.9 of Supply Air Ducts 80.8 of ROOMS 70.0 of h Retum Air Ducts 4 80.2/66.40F M 57.5/56.30F Cooling Coil Supply Fan 2900 cfm 57.5 / 56.3 of Supply Air Ducts 57.9 / 56.5 of 58.8% R.H. ROOMS 74.0/64.1OF h Retum Air Ducts M EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Page:55 of 57 I HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA PKG. HEAT PUMP 16 2,277 ENGINEERING CHECKS ISYSTIRM LOAn Number of Systems 1 Heating System Output per System 140,000 Total Output (Btuh) 140,000 Output (Btuh/sgft) 61.5 Cooling System Output per System 144,000 Total Output (Btuh) 144,000 Total Output (Tons) 12.0 Total Output (Btuhfsgft) 63.2 Total Output (sgftrron) 189.8 Air System CFM per System 4,800 Airflow (cfm) 4,800 Airflow (cfm/sgft) 2.11 Airflow (cfmrron) 400.0 Outside Air (%) 7,7 Outside Air (cfm/sgft) 0.15 Note: values above given at ARI conditions 26.0 OF 66.8 OF Outside Air 342 cfm Supply Fan 4800 cfm 70.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 70,6351 42.4910 LENNOX THA150S 72,757 64,391 92,075 Total Adjusted System Output 72 757 64,391 92,075 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am yam Temperatures at Time of Heating Peakl 66.8 OF 84.70F Heating Col h Retum Air Ducts 4 Supply Air Ducts 84.7 of ROOMS 70.0 of I uuUr,dU 51f5TEM P5YCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.7OF 77.0/69.3OF 77.0/69.2OF 62.9/62.2OF Supply Air Ducts ® Outside Air 342 cfm Supply Fan Coding Cal 63.2 / 62.3 of 4800 cfm ROOMS 75.9% R.H. 74.3/68.60F 74.0/68.5OF Retum Air Ducts EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Paae:56 of 57 1I4VAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE HIDEAWAY CLUBHOUSE 8/31/2005 SYSTEM NAME FLOOR AREA AC -2 & 3 546 Number of Systems 2 Heating System Output per System 37,000 Total Output (Btuh) 74,000 Output (Btuh/sgft) 135.5 Cooling System Output per System 34,000 Total Output (Btuh) 68,000 Total Output (Torts) 5.7 Total Output (Btuhlsgft) 124.5 Total Output (sqf fTon) 96.4 Air System CFM per System 600 Airflow (cftn) 1,200 Airflow (cfrn/sgk) 2.20 Airflow (cfm/Ton) 211.8 Outside Air (°/,) 6.8 Outside Air (cfm/sgft) 0.15 Note: values above given at ARI conditions 26.0 OF 66.6 OF Outside Air 82 cfm Supply Fan 1200 cfm 69.6 °F 11.0 / 77.4 of 3117 Outside Air 82 cfm 74.7/59.9 ° F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 1,057 31,656 10,682 379 16,119 0 950 484 0 0 82 3,182 277 F 82 3,830 0 0 950 484 36,7371 12 659 1 20,917 DECTRON MAM-030 41,006 16,133 0 Total Adjusted System Output a1,0os 16,133 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 4 pm Jan 12 am 66.6oF . 110.0oF Heating Coil �% Return Air Ducts 4 PSYCHROMETRICS 77.2/61.3OF 77.2/61.20F M 45.3/44.20F Supply Fan 1200 cfm Cooling Coil 0..4....x. A:- r%... - Supply Air Ducts 109.6 of ROOMS 70.0 OF Supply Air Ducts IR 46.1 / 44.5 of 42.7% R.H. ROOMS 74.0/59.6OF EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 521 Paoe:57 of 57