04-6141 (CSCS) Title 24
Title 24 - Energy Compliance Documentation Prepared for: Peterson Associates Project Title: THE HIDEAWAY GOLF CLUBHOUSE Snack Bar Building La Quinta, CA CITY OF LA QUINTA A BUILDING & SAFETY DEPT. ® q ED FOR CONSTRUC7.]ON DAI E4�'L L Avg 40R - 0 10308 Placer Lane, Suite 200, Sacramento, CA 95827- 916-364-1786 - FAX 916-364-1789 Envelope Mandatory Measures §I 18(a) Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. §1.18(c) All insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of the Title 24; Part 2. §1.17(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. §I I6(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). §1.16(a)I Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NPRC procedures. §1.18(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than .R-11 between framing members. Lighting Mandatory Measures 5131(d)l For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of section 1.19 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. 513l(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to - exceed 5,000 square feet. §119(h) Automatic Control Devices Certified: All automatic devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. Fluorescent Ballast and Luminaries Certified: All fluorescent fixtures specified for the project are certified and listed in the directory. All installed fixtures shall be certified.. §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescents fixtures are tandem wired with two lamp ballasts were required by Standards Section 132; or all three lamp fluorescents fixtures are specified with electronic high - frequency ballasts and are exempt from tandem wiring requirements. §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. ,§131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 Square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps'in each daylit area controlled by separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on the plans. §131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and corresponding relay in the electrical panel. §131(e) Display Lighting: Display lighting shall be separately switched on circuits that are 20 amps . of less. Mechanical Mandatory Measures EQUIPMENT AND SYSTEM EFFICIENCES §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations with comply with the applicable standard. §115(a) Fan type central furnaces shall not have pilot lights. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. §124 Air handling duct systems shall be installed. and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. CONTROLS §122(e) Each space conditioning system shall be installed with one of the following: §122(E)lA Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of section 122(d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut off" feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time settings for at least 10 hours if power is interrupted; or §122(e)1B An occupancy sensor to control the operating period of the systems; or §122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. §122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. §122(g) Each space conditioning system serving multiple zones with combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. § 122(a&b) Each space conditioning zone shall be controlled by an individual thermostatic control that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55°F or lower. For cooling, the control shall be adjustable up to 85°F or higher. Where used to control both heating and cooling, the control shall be capable of providing a deadband of at least 5°F within which the supply of heating and cooling is shut off or reduced to a minimum. §122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 122(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. VENTILATION §121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. §122(f) Gravity or automatic dampers interlocked and closed on the fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. §122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. §121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licenced C- 20 Mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or §121(f)3 Outside Air Measurement: The System shall be equipped with a calibrated local or remote device capable of.measuring the quantity of outside air on a continuous basis and displaying that quantity on a ready accessible displays; or §121(f)4 Another method approved by the Commission. WATER HEATING SYSTEMS §113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. §113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110° F. §113(b)3C Lavatories in restrooms of public facilities shall be equipped within of the following: -Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. -Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. -Proximity sensors actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. -Self-closing valves, and outlets devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). -Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system) -Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). TITLE as REPORT Title 24 Report for: Hideaway Golf Clubhouse - Snack Bar 52-500 Village Club Drive La Quinta, CA 92253 . Project Designer: H & S International 17785 N. Pacesetter Way, Suite 800 Scottsdale, AZ 85255 i (480) 585-6898 Report Prepared By: Gregory Mize Valley Energy Consultants 10308 Placer Lane, Suite #200 Sacramento, CA 95827-2511 (916)-364-1786 Job Number: 40803 Date: 8/3/2004 rhe EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is s authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy -Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. 40803 User Number. 2531 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 tOJECT NAME DATE Hideaway Golf Clubhouse - Snack Bar _ 8/3/2004___ PROJECT ADDRESS 52-500 Village Club Drive La Quinta PRINCIPAL DESIGNER - ENVELOPE :TELEPHONE i Building Permit # H & S International (480) 585-6898 DOCUMEWTATION AUTHOR tTELEPHONE I Checked by/Date Valley Energy Consultants ` (916) 364-1786 4 Enforcement Agency Use GENERAL INFORMATION I iDATE OF PLANS (BUILDING CONDITIONED FLOOR AREA ;CLIMATE ZONE i 465 sq Ft 15 BUILDING TYPE X! NONRESIDENTIAL U HIGH RISE RESIDENTIAL F -j HOTEL/MOTEL GUEST ROOM ;PHASE OF CONSTRUCTION W1 NEW CONSTRUCTION ADDITION ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE lThis Certificate of Compliance lists the building features and performance specifica ' eeded to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using a pe Qrmanc compliance approach. 1DOCUMENTATION AUTHOR SIGNAICrVE 'k 1 I I ; DATES , Greao_yr Mize Fhe Principal Designers hereby certify that the proposed bui 'or this permit application are consistent with all other forms 1 )ermit application. The proposed building as designed meets ?4, Part 6. ENV. LTG. MECH. d in the dorvfruction documents and m(fdelled j cations, and other calculations submitted with this ' requirements of the State Building Code, Title 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to J sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. J u 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section (' 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed i contractor preparing documents for work that I have contracted to perform. iu 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document — because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) i ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures 1 Required Forms 1 ENy-1 (PRINCIPAL ENVELOPE DESIGNER - NAME j SIGNATURE 'LIC. NO. DATE H & S International ' ZgS? 1 F,'-10-0� LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory asures I : Required Forms . LTG -1, LTG -3 PRINCIPAL LIGHTING DESIGNER - NAME SI NATURE LIC. NO. 'D TE Peterson Associates . /til 0.0 MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms, RINCIPAL MECHANICAL DESIGNER - NAME SIGNAT R Peterson Associates I ECH-1, MECH-2, MECH-3 . �— ;LIC. NO. 'DATE Run Initiation Time: 08/03/04 08:11:26 Run Code: 1091545886 EnergyPro 3.1 By EnergySoft User Number. 2531 Job Number. 40803 Page:2 of 13 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 Hide r-'r%lf - (Znnr-L- Pnr DATE [M. ANNUAL SOURCE ENERGY USE SUMMARY (kBtu/sqft- yr) Conditioned Floor Area 465! sqft. Number of Stories Standard Proposed Compliance 11 ENERGY COMPONENT Design Design Margin PZP;--eJ-7 Space Heating 7.10; 5.81 1.29! Gross Area Glazing Area Glazing Ratio Front Elevation (South) i 2701 sqft. i .17jsqft. i 6.3%1 Left Elevation 1 (West); 1 236 i sqft. I Otsqft. 0.0%i Rear Elevation (North)I 27011 sqft. Oisqft. 1 0.0%; Right Elevation (East)! Space Cooling 76.131: 67.10; 1 9.03! Roof Indoor Fans 30.971 39.351 -8.39i N,6 Standard Proposed LEEDTM Energy & Atmosphere Credit Lighting Power Density 1.407!W/sqft. 44 W/sqft. i Savings vs. Title 24 16.54% Heat Rejection i 0.00 0.00i 0: 0.0 , "k Prescriptive Env. Heat Gain i HUMPS & Misc. i 8,3521 Btu/h-F 1. excludes process and receptacle 2. see LEED table 8-c or 8-d 0 .00 0.001 .It Remarks: Domestic Hot Wateri 8.391 8.39, 1 0.001 1 Lighting i 41.291 16.131 1 25 16 sLW7,li A 1. Receptacle I 19.351 1 19.35! 1 0 i LOA., Process O.M - 0.001 0.00! 41 W 0� 10 420- . 30, 40 5 TOTALS: 183.23 Percent better than Standard: iSr, VIA 27 in 14.8% ( 14.8% excluding process) Building Orientation (South) 18odegl Conditioned Floor Area 465! sqft. Number of Stories 11 Unconditioned Floor Area 01 sqft. . Number of Systems 11 Conditioned Footprint Area 1 4651 sqtt. Number of Zones 21 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation (South) i 2701 sqft. i .17jsqft. i 6.3%1 Left Elevation 1 (West); 1 236 i sqft. I Otsqft. 0.0%i Rear Elevation (North)I 27011 sqft. Oisqft. 1 0.0%; Right Elevation (East)! 2331 sqft. 1! 41 sqft. 1 1.7%i Total 1,0091 sqft. i 2112.1%1 sqft. :L Roof 4651 sqft. i 0 sqft. 0.0%1 Standard Proposed LEEDTM Energy & Atmosphere Credit Lighting Power Density 1.407!W/sqft. 44 W/sqft. i Savings vs. Title 24 16.54% Prescriptive Env. Heat Loss 1461 Btu/h � Btu/h 1 Energy Performance Credit 3 Points Prescriptive Env. Heat Gain i 17,163!Btu/h-F i 8,3521 Btu/h-F 1. excludes process and receptacle 2. see LEED table 8-c or 8-d Remarks: rneravPro 3.1 By EneravSoft User Number. 2531 Job Number. 40803 Page:3 of 13 �PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1' tUJtG I NAMt DATE Hideaway Golf Clubhouse - Snack Bar 8/3/2004 ZONE INFORMATION System Name Zone Name anc Type Occupancy Y YP Floor Area (sgft.) Inst. LPD (W/sf)l Port. LPD (W/sf)l Ctrl. Credits (W/sf)2 Tailored Proc. Loads (W/sf) LPD (W/sf) 3 HP16 wi CU16 Snack Bar Kitchen & Food Prep 341 0.727 0.000 0.145 Restrooms Corridor/Restroom/Support 124 0.548 0.000 0.110 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTGA Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines *k- -.4- ..-....-FAL...:...-♦:[:....L:..........J........-" -�__-__'_—_.. .. --- ----a--- -- ---- ♦---------•-••. -••- •••--I •..i ..... .............y — va..a.y., a. Awa vu lc,.. qac --pwl uaJvu vu Lim dUuq Udl:y W the Special and documentation submitted. I The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp EnergyPro 3.1 By EnergySoft User Number: 2531 Job Number: 40803 PageA of 13 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 :OJECT NAME DATE Hideaway Golf Clubhouse - Snack Bar 8/3/2004 OPAQUE SURFACES Type Area U -Fac. Act. Azm. SHGC Glazing Type Location ! Comments Window 6 0.720 # Surface Type Framing Type Area Act. U -Fac. Azm. Tilt Solar Gains Y/N Form 3 Reference Location ! Comments 1 Roof Wood 341 0.028 0 0 X R-38 Roof (R.38.2x14.16) Snack Bar 2 Wall Wood 94 0.065 0 90 X].__ R-19 Wall 0.19.2x6.16 Snack Bar 3 Wall Wood 116 0.065 90 90 X R-19 Wall (W.19.2x6.16) Snack Bar 4 Door Wood 32 0.387 90 90 X Solid Wood Door Snack Bar 5 Wall Wood 253 0.065 180 90 X R-19 Wall (0.19.2x6.16) Snack Bar 6 Wall Wood 236 0.065 270 1 90 X R-19 Wall W.19.2x6.16 Snack Bar 7 Roof Wood 124 0.028 0 0R-38 Roof R.38.2x14.16 Restrooms 8 Wall Wood 134 0.065 0 90 X R-19 Wall (W.19.2x6.16) Restrooms 9 Door Wood 42 0.387 0 90 Window Hgt. Wd. Solid Wood Door lRestrooms 10 Wall Wood 81 0.065 90 90 X R-19 Wall W.19.2x6.16) Restrooms 0.76 3 None 0.76 FENESTRATION SURFACES Run Initiation Time: 08/03/0408:11:26 Run Code: 1091545886 Site Assembled Glazing Check box if Building is — 100,000 sqft of CFA and — 10,000 sgft vertical glazing then NFRC Certification is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form. 4f Type Area U -Fac. Act. Azm. SHGC Glazing Type Location ! Comments Window 6 0.720 180 0.77 Double Clear Default(NM) Snack Bar Window 11 0.760 180 0.77 Double Clear Default NM nack Bar 3 Window 4 0.720 90 0.77 Double Clear Default NM Restrooms EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. Hgt. Right Fin Dist. Len. H t. 1 None 0.76 _ 2 None 0.76 3 None 0.76 Run Initiation Time: 08/03/0408:11:26 Run Code: 1091545886 EnergyPro 3 1 By EnergySoft User Number: 2531 Job Number: 40803 Page:5 of 13 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -11 tOJECT NAME DATE Hideaway Golf Clubhouse - Snack Bar 1 8/3/2004 1 INSTALLED LIGHTING SCHEDULE I Aeeac I RAI I ARTS 11 Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Lamp DESCRIPTION # (Lamp + # tsaiiasty, Watts Total Watts B 2 4 ft Fluorescent T8 Elec F32T8 2 32 Electronic 1.0 4 62.0 248 E (1) 13w Compact Fluorescent Twin 2 Pin CFT13W/GX23 1 13 Magnetic Standard 1.0 4 17.0 68 Subtotal from this Page 316 Lighting Schedule on Plans Shows Exterior Lighting Meets Total 316 Portable Lighting (From LTG -1) ❑Efficacy and Control Requirement of §130(c) Less Control Credit Watts (From LTG -3) 63 ❑Control Requirements of §131(0 Adjusted Actual Watts 253 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE NOTE TO (Room #) IDENTIFICATION (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED FIELD I"s CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED TYPE 1# OF LUMINAIRES Snack Bar Occ Sensor — 250 sqft B 4 Restrooms Occ Sensor — 250 sqft E 4 LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 tOJECT NAME Hideaway Golf Clubhouse - Snack Bar TOTAL AREA (SF) (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) DATE I 8/3/2004 TABLE 1A - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET N o a a ROOM # OR ZONE ID DEFAULT (W/sgft) AREA (SF) TOTAL WATTS (B X C) TOTAL 0 0 TABLE 16 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET o a ROOM # PORTABLE LIGHTING a o 0 o a LUMIN. TASK # OF TOTAL TOTAL # OF WATTS PER AREA TASK AREA (SF) WATTS TABLE 1C - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # TOTAL AREA OR ZONE ID (SF) TOTAL 1 0 BUILDING SUMMARY - PORTABLE LIGHTING Designer needs to provide detailed documentation that the ligl level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL 0 0 EnergyPro 3.1 By EnergySoft User Number: 2531 Job Number: 40803 Page:7 of 13 CERTIFICATE OF COMPLIANCE Performance MECH-1 20JECT NAME DATE Hideaway Golf Clubhouse - Snack -Bar I 8/3/2004 SYSTEM FEATURES CODE TABLES: Enter code from table below into columns above. I HEAT PUMP THERMOSTAT? Y: Yes VC No MECHANICAL SYSTEMS SETBACK CTRL. NOTE TO FIELD SYSTEM NAME DHW HeaterHP16 w/ CU16 H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/ COOL? TIME CONTROL VENTILATION n/a Programmable Switch O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural SETBACK CONTROL A: Air W: Water N: Not Required EC: Economizer Control See Section 144(e)3 n/a Heating & Cooling Re wired PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE ISOLATION ZONES n/a n/a HEAT PUMP THERMOSTAT? n/a Yes ELECTRIC HEAT? n/a 0.0 kW FAN CONTROL n/a Constant Volume VAV MINIMUM POSITION CONTROL? n/a No SIMULTANEOUS HEAT/COOL? n/a No HEATING SUPPLY RESET n/a Constant Temp COOLING SUPPLY RESET n/a Constant Temp HEAT REJECTION CONTROL n/a n/a VENTILATION n/a Air Balance OUTDOOR DAMPER CONTROL n/a Auto ECONOMIZER TYPE n/a No Economizer DESIGN O.A. CFM (MECH-3, COLUMN 1) n/a 161 cfm iEATING EQUIPMENT TYPE Electric Res Heat Pump HEATING EQUIPMENT EFFICIENCY 100% 7.50 HSPF COOLING EQUIPMENT TYPE n/a Split DX COOLING EQUIPMENT EFFICIENCY n/a 10.7 SEER / 9.4 EER MAKE AND MODEL NUMBER O Smith PEC -066 or Equal Lennox HP29-036, CB29M- 41 PIPE INSULATION REQUIRED? Yes . Yes PIPE/DUCT INSULATION PROTECTED? Yes No HEATING DUCT LOCATION R -VALUE n/a n/a Ducts in Attic 4.2 COOLING DUCT LOCATION R -VALUE n/a n/a Ducts in Attic 1 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE n/a No CODE TABLES: Enter code from table below into columns above. I HEAT PUMP THERMOSTAT? Y: Yes VC No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/ COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144(e)3 Enter Outdoor Air CFM_ Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE FneravPro 3.1 By EneravSoft User Number. 2531 Job Number: 40803 Page:8 of 13 LIGHTING CONTROL CREDIT WORKSHEET LTG -3 ROJECT NAME Hideaway Golf Clubhouse - Snack Bar 8/3/2004 FW -OR KS HE ET |. nooM DAYLIGHTING 1 ! WATTS mF �uunnmu ! 'CONTROL/ LIGHTING CONTROL pLxwu !/ AREA i! nooM ' ouunmo !cowrnoL|xoxuur 'CREDIT WATTS DESCRIPTION ' nsp. (SF) n»Tm^ � vLr | uo*nwG rxoTon � ' ucc Sensor^=/av / �4f sqft �� ��� ��� L 20' 50 Occ Sensor 250 ��� sqft �--_—' / /�_ � i ii �� / IF � �-------� ! �-------�|-------� / �-------| ' �---------------�-------� | / | i � �—_-----� | �------� �-------� | �. /. �-------?[------- --------' ' L PAGE TOTAL 63t . .� \ | � �—_ ^For windows, use the Window Wall Ratio for the room. For skylights, use the axyouxt-m'nvmratio for the room. ! BUILDING TOTAL 63i Enter onoG-1 and 2: Actual Lighting Power suxmxuon. | | s"eropm3., o,Enamxmm User Number 2531 Job Number. 40803 pag°*mm | MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME DATE Hideaway Golf Clubhouse - Snack Bar 8/3/2004 ..,HILLER AND TOWER SUMMARY PUMPS Tot Motor Drive Pump Equipment Name i Equipment Type Qty. Efficiency Tons Qty GPM BHP Eff. Eff. Control i1 — ; i - — -- '.3 ICENTRAL SYSTEM FAN SUMMARY SUPPLY FAN i RETURN FAN i Motor' Drive; Motor j Drive i LSystem Name y Fan T i Motor Location CFM 1 BHP Eff. I Eff. CFM BHP Eff. I Eff. nnoHP29-036, CB29M i41 Constant Volume :Blow -Through 1,200! 0.31, 77.0%; 97.0%; none: I � i I i! ---I- I EnerqyPro 3.1 By EnergySoft User Number. 2531 Job Number. 40803 Page:10 of 13 IQHW I BOILER SUMMARY System Name System Type j Distribution Type Energy FactorStandby TANK INSUL.!; Rated Vol. j or Recovery Loss or Ext IQtyj input (Gals.) Efficiency I Pilot j R -Val. !I: kO Smith PEC 066 or jEqual !Storage Elec. !Standard 15,359! 601 0.871 n/al n/a! ; ICENTRAL SYSTEM RATINGS ICENTRAL SYSTEM FAN SUMMARY SUPPLY FAN i RETURN FAN i Motor' Drive; Motor j Drive i LSystem Name y Fan T i Motor Location CFM 1 BHP Eff. I Eff. CFM BHP Eff. I Eff. nnoHP29-036, CB29M i41 Constant Volume :Blow -Through 1,200! 0.31, 77.0%; 97.0%; none: I � i I i! ---I- I EnerqyPro 3.1 By EnergySoft User Number. 2531 Job Number. 40803 Page:10 of 13 A MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME NE Hideaway Golf VAL SUMMARY EXHAUST FAN SUMMARY se - Snack Bar VAV TERMINAL BOX Min. CFM Reheat Coil S stem Type ply. Ratio Type DeltaT DATE EXHAUSTFAN ECHAUST AN Room Name Qty. CFM I BHP Motor Eff. Drive Eff. Room Name Qty_ CFM BHP I Motor Eff. Drive Eff. Restrooms 1.0 110 0.08 77.00/c 97.0% Run Initiation Time: 08/03/04 08:11:26 Run Code: 1091545886 EnerovPro 3.1 By EnergvSoft User Number: 2531 Job Number: 40803 Page: 11 of 13 MECHANICAL VENTILATION MECH-3 IOJECT NAME DATE Hideaway Golf Clubhouse - Snack Bar 8/3/2004 MECHANICAL VENTILATION FA ©© a o o© o o a o EnergyPro 3.1 By EnergySoft User Number: 2531 Job Number: 40803 Page:12 of 13 AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAVTRANS- MIN. RATIO FER AIR ZONE/SYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Snack Bar 341.0.15 51 3.4 15.0 51 51 51 Restrooms 124 0.15 19 1.2 15.0 19 19 110 HP16 w/ CU16 Total 70 161 RE I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 2531 Job Number: 40803 Page:12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY - -- 1DROJECT NAME Hideaway Golf Clubhouse - _ YSTEM NAME HP16 w/ CU16 --- . _........... ---- Snack Bar -- ---- - -- --- _ ---- ... --- .. DATE 8/3/2004 FLOOR AREA 465 ENGINEERING CHECKS SYSTEM LOAD :,!Number of Systems 1;, _COIL COOLING PEAK ° , COIL HTG. PEAK .Heating System CFM Sensible' Latent i CFM Sensible _Output per System 30,600! ; Total Room Loads 861 10,344' 1,800'' 923: 9,029, Total Output (Btuh) 30,600;1 Return Vented Lighting 0. ; Output (Btuh/sgft) 65.8j,! Return Air Ducts 517; _ 451 ;Cooling System :: Return Fan 01 01 Output per System 34,600!;'; Ventilation 161, 6,616; 736 7,482' —Total Output(Btuh) 34,60011i Supply Fan of _161; _ o' ' j Total Output (Tons) I 2.9-I Supply Air Ducts 517; 451;' Total Output (Btuh/sgft) ' 74.4! ' ! ! ! TOTAL SYSTEM LOAD 17,994; I ' 2,536. 17,414; Total Output (sgft/Ton) 161.3;1' - ------ i iAir System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/ron) Outside Air (%) j Outside Air (cfm/sqft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 1,200i:'. ,!Lennox HP29-036, C629M-41 22,062i 9,8601 1,20011!i' r i 2.58!I�j— -- 4162!!' _- 3 I! Total Adjusted System Output 22062{T9,89,860] (Adjusted for Peak Design Conditions) ,_— - l TIME OF SYSTEM PEAK i Aug 3 pm Temperatures at Time of Heatina Pea 20,125; I 20,125; Jan 12 am 26.0 OF 63.8 OF 63.8 OF 79.6 of Outside Air 1150 -) Supply Air Ducts 161 cfm o 1 Supply Fan Heating Coil 792 F 1200 cfm ROOMS: ' 70.0 °F 69.6 of Return Air Ducts F (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolinq Peak) I 13.0 / 77.9 OF Outside Air 161 cfm '4.4 / 65.8 of 79.6/67.6OF (D7 79.6/67.60F 111111111 62.3/61.30F Supply Fan Cooling Coil 1200 cfm h Return Air Ducts ',� Supply Air Ducts i 62.7/61.5OF 64.9% R.H. ; ROOMS 74.0 / 65.7 of I EnergyPro 3.1 By EnergySoft User Number. 2531 Job Number. 40803 Page: 13 of 13